1、SPE通过固相萃取进行样品富集和纯化为何使用固相萃取(SPE)技术1. 您需要从样品中去除特定干扰物,以免它们在目标分析物的检测和定量过程中影响实验结果。在此处所示的示例中,不适当的样品制备方案未能去除干扰物,导致提取物呈现出残留的黄色干扰物,色谱图中目标分析物与多个干扰峰发生了重叠。 2. 您需要提高初始样品中目标分析物的浓度,以便所用的分析技术能够更轻松地对其进行检测和准确定量。如果目标分析物可被较强地保留,那么可能需要在SPE色谱柱上加载较大的样品量,随后仅以极小体积的洗脱液将此分析物洗脱下来,由此提高样品中分析物的浓度。
2、0;3. 您需要去除样品中的干扰物(即使不可见),这些干扰物会在质谱检测中抑制目标分析物的信号。在此处的示例中,蛋白沉淀法无法去除血浆提取物中的磷脂,从而造成严重的离子抑制。优化的复合模式SPE方案可获取最纯净的提取物,并可在最大程度上降低离子抑制效应。 What is Solid-Phase Extraction (SPE?Don't be confused by the term solid-phase extraction SPE. A typical SPE device has 50 times more separation power than a simple
3、, single liquid-liquid extraction. SPE is actually column liquid-solid chromatography. Since SPEis liquid chromatography LC, its practice is governed by LC principles. A sample is introduced into a column or a cartridge device containing a bed of appropriate particles, or other form, of a chrom
4、atographic packing material stationary phase. Solvent mobile phase flows through the bed. By choosing an appropriate combination of mobile and stationary phases, sample components may pass directly through the column bed, or they may be selectively retained.Individual compounds in the sample each ty
5、pically appear to travel at different speeds through the device. Using a weaker solvent causes them to move slowly and/or be strongly retained. A stronger solvent speeds up their passage through the bed and elutes the analyte(s in a more concentrated volume. Elution from an SPE device is usually don
6、e by increasing the strength of the mobile phase in a series of discrete, rather than continuous, steps during which selected analytes or interferences are either fully retained or rapidly eluted-this variation of gradient elution called a step gradient.Most commonly, SPE is practiced using min
7、iature column or cartridge devices. An example is shown here. A mixture of three dyes is loaded onto the cartridge in a weak solvent, causing strong sample retention in a narrow band that appears black at the column inlet. Subsequent gradient steps, each with a successively stronger solven
8、t, are used to elute the dyes individually yellow, red, then blue. Typical SPE cartridges are low-pressure devices-constructed of solvent-resistant plastic or glass-filled with particles 30 µm in diameter. Suitable flow rates may be achieved by gravity or with the assistance of vacuu
9、m or low positive pressure. The latter requires putting a cap on the open inlet of a column or using a sealed device with inlet and outlet fittings.Importance of Sample PreparationIn the last two decades, dramatic advances in analytical instrumentation and laboratory information management systems s
10、hifted the analyst's predominant tasks from assay measurements to sample preparation and data processing. As the stringency of requirements for higher sensitivity, selectivity, accuracy, precision, and number of samples to be processed has escalated, the corresponding increases in speed and soph
11、istication of analysis and data collection have outpaced improvements in the many traditional techniques of sample collection and preparation. By some estimates, 75 to 80% of the work activity and operating cost in a contemporary analytical lab is spent processing and preparing samples for introduct
12、ion or injection into an analytical separation and/or measurement device. Clearly, efforts directed and products designed to streamline sample preparation protocols are essential to future progress in analytical science.Goals of Sample PreparationSuccessful sample preparation for most analytical tec
13、hniques HPLC, GC, spectrophotometry, RIA, etc. has a threefold objective: namely, to provide the sample component of interest in solution free from interfering matrix elements at a concentration appropriate for detection or measurement.To accomplish these goals, a sample, or a representative portion
14、 thereof not always easy to obtain, is preparedvia traditional methods of dissolution, homogenization, extraction liquid- or solid-phase, filtration, concentration, evaporation, separation, chemical derivatization, standardization internal or external, etc.Usually such methods are used in combi
15、nations of multiple steps, which form a sample prep protocol. The fewer steps and methods used in any given protocol, the simpler, more convenient, cost effective, and less time consuming it is. Simpler protocols lend themselves more readily to automation and also lead to increased accuracy, reliabi
16、lity, reproducibility, and safety.Innovation in Sample Preparation MethodsThere are many ways to combine standard tools and techniques to accomplish the goals of sample prep. However, it is best to seek innovative means to streamline sample prep protocols: to combine the functions of several steps,
17、if possible, into one operation; to eliminate needless sample transfers and manipulations; to reduce the scale as much as practicable gaining economies of time, labor, and cost; to use new tools in creative ways.Benefits of Solid-Phase Extraction SPE CartridgesWhen compared to other sample preparati
18、on processes, solid-phase extraction using SPE cartridges offers:Lower Cost lower solvent consumption lower reagent consumption less apparatusGreater Recoveries minimal sample transferFaster Protocol fewer stepsGreater Safety less exposure to toxic agentsGreater Accuracy no cross contami
19、nationNo Emulsion Problems less sample handling fewer stepsNo Transporting of Samples to Lab direct field samplingReduced Harm to Labile Samples minimal evaporationMinimal Glass Breakage less glassware used, less to washAchieving Sample Preparation Objectives with Solid-Phase Extraction SPE To remov
20、e sample constituents that elute after the analytes of interest or are strongly adsorbed: use solid-phase extraction with sorbent surface chemistry that is the same as that in the analytical HPLC column. tailor the gradient steps to elute analytes selectively. To remove sample constituents that coel
21、ute with an analyte of interest: use solid-phase extraction with sorbent surface chemistry and/or separation mode different from that in the analytical column. tailor the gradient steps to elute analytes selectively. To enrich sample components present in low concentration: tailor the gradient steps
22、 to elute analytes selectively. use "large" sample volumes in adsorption-promoting solvent. use "small" collection volume in desorption-promoting solvent. use sorbent chemistry tailored to the analyte, independent of that in analytical column. carefully choose chemistry of solid-
23、phase extraction column so further sample prep will be unnecessary. To desalt samples: first, adsorb analytes on reversed-phase sorbent while salt breaks through unretained. then, after using water to wash away residual salt, desorb analytes using water-miscible organic solvent. To exchange solvents
24、: adsorb the sample completely onto a strongly retentive sorbent and flush away the original solvent with a weaker eluent. elute the analyte with the desired solvent. To fractionate classes of compounds: use a step-gradient sequence to divide a sample-on the basis of hydrophobicity, polarity, or cha
25、rge-into fractions containing groups of analytes that share common properties. To derivatize analytes using solid-phase reagents: adsorb a derivatization reagent on the surface of the sorbent; then, collect the sample (usually a gas under conditions that favor complete adsorption of the analyte; wai
26、t for the reaction to occur and then selectively elute the derivative.SPE is ChromatographyKeep in mind that solid-phase extraction has the same fundamental basis as HPLC. Any knowledge of the chromatographic behavior of the analytes of interest, and of other matrix components, can help in choosing
27、the proper sorbent and eluents. If, for example, you know that certain chromatographic conditions provide excellent separation of your analyte from interferences, then you may choose a similar SPE sorbent and solvent combination. Similarly, if you are trying to remove an interference that coelutes i
28、n HPLC, then you know a priorithat similar SPE conditions will not be successful.General Elution ProtocolsThere are two general strategies for isolating and cleaning up sample components of interest: adsorb matrix interferences while components of interest pass through the cartridge unretained.
29、 adsorb components of interest while matrix interferences pass through the cartridge unretained.The first strategy is usually chosen when the desired sample component is present in high concentration. When components of interest are present at low levels, or multiple components of widely differing p
30、olarities need to be isolated, then the second strategy is generally employed. Trace enrichment of compounds present at extremely low levels and concentration of dilute samples are also achieved by the second strategy.Steps of a Solid-Phase Extraction ProcedureThe following section describes the ste
31、ps involved in a complete solid-phase extraction procedure. In many applications, one or more of the steps, listed below and subsequently described by general examples, can be omitted, thereby simplifying the procedure. The procedures illustrated here use samples containing dyes so that separations
32、may be easily visualized. Keep in mind that most samples contain colorless components that require some type of detector or test to locate them in the collected fractions. Use the following information as a guideline in the development of your own procedure or when modifying procedures published in
33、the literature.1. Pretreatment of the sample2. Conditioning of the cartridge3. Loading the sample4. Elution of the fractionsPrincipal Separation Modes in Solid-Phase Extraction SPENormal-Phase ChromatographyThis mode is classically used to separate neutral organic compounds whose chemical nature ran
34、ges from hydrophobic to moderately polar.To perform normal-phase chromatography with SPE cartridges, use a step gradient of nonpolar solvents with a polar packing material.1. Condition the cartridge with six to ten hold-up volumes of non-polar solvent, usually the same solvent in which the sample is
35、 dissolved.2. Load the sample solution onto the cartridge bed.3. Elute unwanted components with a non-polar solvent.4. Elute the first component of interest with a more polar solvent.5. Elute remaining components of interest with progressively more polar stronger solvents.6. When you recover all of
36、your components, discard the used cartridge in a safe and appropriate manner.This procedure is illustrated in the figure below for a sample containing a mixture of three neutral, relatively non-polar organic dyes yellow, red, and blue that appears black when initially loaded onto the cartridge bed.&
37、#160;Illustration of a General Elution Protocol for Normal-Phase Chromatography on SPE Cartridges(Silica, Florisil, Alumina, Diol, CN, NH2 Reversed-Phase ChromatographyBecause of the multiplicity of aqueous samples spanning a breadth of applications from environmental water to fruits and vegeta
38、bles, from beverages to biological fluids, reversed-phase chromatography has become the predominant mode of SPE.To perform reversed-phase chromatography with SPE cartridges, use a gradient of strongly to weakly polar solvents from weak to strong solvent elution strength with a non-polar packing mate
39、rial.1. Solvate the silica-bonded phase or polymer packing with six to ten hold-up volumes of methanol or acetonitrile. Flush the cartridge with six to ten hold-up volumes of water or buffer. Do not allow the cartridge to dry out unless using HLB.2. Load the sample dissolved in a strongly polar weak
40、 solvent typically water.3. Elute unwanted components with a strongly polar solvent.4. Elute weakly retained components of interest with a less polar solvent.5. Elute more tightly bound components with progressively more non-polar stronger solvents.6. When you recover all the components of interest,
41、 discard the used cartridge in a safe and appropriate manner.This procedure is illustrated in the figure below for a sample of an aqueous grape drink containing two polar food dyes red and blue, as well as sugar and artificial flavor but no real grape juice!. As prepared, this drink appears light pu
42、rple in a glass, since the dye concentration is dilute. When a portion is loaded onto a prepared SPE cartridge, the strongly retained dyes become concentrated near the inlet in a dark purple band. Illustration of a General Elution Protocol for Reversed-Phase Chromatography on SPE Cartridges(C18
43、, tC18, C8, CN, Diol, HLB, Porapak RDX, NH2 Ion-Exchange ChromatographyCompounds that are ionic or ionizable are often best isolated using some form of ion-exchange chromatography. This separation mode is orthogonal to the more widely used normal-phase and reversed-phase modes and provides a po
44、werful, selective second dimension to sample preparation protocols. Illustration of the Two Major Types of PhasesAnion and Cation Exchangeand How They Selectively Attract and Retain Molecules of Opposite Charge To perform ion-exchange chromatography with SPE cartridges, use a gradient of p
45、H or ionic strength with an ion exchange packing material.1. Condition the cartridge with six to ten hold-up volumes of deionized water or weak buffer.2. Load the sample dissolved in a solution of deionized water or buffer.3. Elute unwanted, weakly bound components with a weak buffer.4. Elute the fi
46、rst component of interest with a stronger buffer (change the pH or ionic strength.5. Elute other components with progressively stronger buffers.6. When you recover all of your components, discard the used cartridge in an appropriate manner.This procedure is illustrated in the figure below for a samp
47、le of an aqueous mixture of two ionic dyes with different pKa values. When loaded onto the cartridge, both are strongly retained, and the combination of blue and yellow components appears as a green band near the inlet. Illustration of General Elution Protocol for Ion-Exchange Chromatograp
48、hy on SPE Cartridges(NH2, Accell Plus QMA, Accell Plus CM, SCX, SAX, WCX, WAX Cation and anion exchangers are further categorized as either weak or strong exchangers, depending upon the type of ionic group on their surface. Strong cation exchangers possess an acidic surface moiety such as
49、a sulfonic acid that is always ionized negatively charged over the whole pH range. Weak cation exchangers possess an acidic surface moiety such as a carboxylic acid that is negatively charged at high pH but neutral at low pH. Similarly, strong anion exchangers typically bear quaternary ammonium grou
50、ps that are always positively charged, while weak anion exchangers possess primary, secondary, or tertiary amine groups that may be positively charged at low pH but neutral at high pH. Use the following table as a guideline to choose the appropriate SPE ion-exchange cartridge type for your part
51、icular analyte. Mixed-mode ion exchange chromatography combines the use of reversed-phase and ion-exchange modes into a single protocol on a single SPE cartridge. It can be used to isolate and separate neutral, acidic, and basic compounds from a single complex matrix. An ideal mixed-mode SPE so
52、rbent substrate remains water-wettable while exhibiting strong reversed-phase retention of hydrophobic compounds. On its surface are ion-exchange functionalities of one of the four general types just described above. Intermediate washes with organic solvent mixtures of appropriate elution strength m
53、ay be used to isolate neutral compounds including ionizable analytes in their neutral state. Selective elution of ionically bound analytes may be attained by manipulating the charge of either the analyte when bound to strong ion exchangers or of the sorbent for analytes bound to weak ion exchangers.下表汇总了各种SPE模式,为方法开发工作的开展提供了一个良好的起点:固相萃取选择色谱模式及吸附剂 反相正相离子交换分析物中-低极性低-高极性/中性 带电荷、可电离分离机制基于疏水性的分离基于极性的分离基于电荷的分离样品基质水溶液非极性有机溶剂水溶液/低离子强度SPE吸附剂的活化/平衡1. 用极性有机溶剂得到的溶剂化物2. 水非极性有机溶剂低离子强度缓冲液初步冲洗步骤水溶液/缓冲液非极性有机溶剂低离子强度缓冲液洗脱步骤增加极性有机溶剂的含量增加混合有机溶剂的洗脱强度更强
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 6《比例尺》大单元整体设计(教学设计)-2024-2025学年六年级上册数学冀教版
- 2023二年级数学上册 七 分一分与除法第4课时 分香蕉配套教学设计 北师大版
- 2023三年级数学上册 二 观察物体第1课时 看一看(一)教学设计 北师大版
- 毕业论文课题答辩汇报
- 7 中华民族一家亲 第一课时 (教学设计)-部编版道德与法治五年级上册
- Unit5 Drink Lesson 1(教学设计)-2023-2024学年人教新起点版英语一年级下册
- 胰体尾脾切除护理
- Unit 3 Lesson 2教学设计 2024-2025学年冀教版(2024)七年级英语上册
- 2024秋九年级化学上册 第三单元 物质构成的奥秘 课题2 原子的结构第2课时 原子核外电子的排布 离子教学设计(新版)新人教版
- 6《骑鹅旅行记(节选)》教学设计-2023-2024学年统编版语文六年级下册
- SY∕T 7298-2016 陆上石油天然气开采钻井废物处置污染控制技术要求
- 电梯门系统教学课件
- 四年级下册数学课件-第四单元小数点移动引起小数大小的变化 课时(2)人教新课标 (共20张PPT)
- 核科普知识学习考试题库(400题)
- 六年级数学试卷讲评课教学设计(共16篇)
- 线面平行判定定理
- 轮扣式模板支撑架专项施工方案
- abb继电保护615系列操作手册
- 甘肃省审图机构
- 挖掘机部件英语对照表
- 办公室口号大全
评论
0/150
提交评论