版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
Theisolatingswitch第9页共9页InstructionforinstallationandtestTheisolatingswitch1.Relateddocumentationsandstandards1.1.TheChinesestandard(GBJ147-90):Codeforconstructionandacceptanceofthehighvoltageequipment1.2.TheChinesestandard(GB50150-91):Standardforhand-overtestofelectricequipment1.3.TheChinesestandard(DL408-91):Operationcodeforpowerplantsafety1.4.TheChinesestandard(DL560-95):Operationcodeforelectricsafetyinhighvoltagelaboratory1.5.TheChinesestandard(DL/T5043-95):Designstandardforelectricallaboratoryofthermalpowerplant1.6.TheChinesestandard(DL/T5161.2-2002):Specificationforconstructionqualitycheckoutandevaluationofelectricequipmentinstallation2.Receiptandstorage2.1.Examinethestateofthedevicesandthematerialsreceivedtocheckthatitcorrespondswithwhatwasordered.2.2.Checkallpackagesforexternalsignsofdamage.2.3.Pleasecheckconditionandqualityofthedevicesandthematerials,andcomparethemwiththepackinglist.2.4.Ifonunpacking,whichmustbecarriedoutcarefully,anydamageorirregularityisnoted,notifythiswithindefiniteperiodofreceiptofthegoods,notificationmustindicatetheshippingnotenumber.2.5.Ifthedevicesistobestoredforevenshortperiodsbeforebeingputintoservice,afterreceiptitisadvisabletoputitbackintoitsrelativecontainerandcoveritwithawaterprooftarpaulin.Useadryanddust-freeambientforstoragewithoutanyaggressivechemicalagents.Placethedeviceandanyfixedpartonahorizontalsurfacenotindirectcontactwiththefloor,butonasuitablesupport.2.6.Selectalocationforthedeviceinaclean,dry,vibration-freeareawithmoderatetemperature.2.7.Withregardtolifting,followtheseinstructions:thedevicesmustbeplacedonasturdysurfaceandpreferablyliftedusinganappropriateliftingforktruck.Theuseofropesis,however,permitted:inthiscasetheliftingropesmustbehookedfirmly.3.Installation3.1.Allcomponentparts,auxiliaryparts,sparepartsshouldbecomplete,notdamage,deformedorcorroded.Porcelainpartsshouldhavenocrackordamage.Equipmentsandporcelainpartsshouldbesafelystored,shouldnotbedamagedbybeinginclinedorfallingdown.Anticorrosionmeasuresshouldbetakenformetallictransmissionpartsofcontactsandoperatingmechanisms.3.2.Connectionterminalsandconductingpartsareclean,contactsaregood,nopeelingonsilverplatedlayerofthecontactsurfaces.Insulatorsurfaceshouldbeclean,nocrack,nodamageandnoweldingresidualspots.Theporcelainpartsshouldbefirmlycementedtoironfittings.Rotatingpartsoftheisolatingswitchbaseshouldrotatefreelyandbepastedwithlubricatinggreasesuitableforthelocalclimate.Componentpartsoftheoperatingmechanismsshouldbecomplete,allfixedconnectionpartsshouldbefirmlytightened,lubricategreasesuitableforthelocalclimateshouldbeappliedtorotatingparts.3.3.Assemblageoftheisolatingswitchesshouldconformtofollowingrequirements:3.3.1.Deviationofdistancesbetweenphasesshouldnotbegreaterthan10mmforvoltage110kVandbelowand20mmforvoltageabove110kV.Theinterconnectingrodsbetweenphasesshouldbeonasamelevel.3.3.2.ThepostinsulatorsshouldbeperpendiculartotheirbaseplaneexceptVtypeisolatingswitchesandbeconnectedfirmly.Insulatorcenterlinesofsameinsulatorcolumnshouldbeonsameperpendicularline.Insulatorcolumncenterlinesofsamephaseshouldbeonsameperpendicularplane.3.3.3.Insulatorcolumnsofsameisolatingswitchshouldbeconnectedfirmly.Metalpadscanbeusedtocompensatehorizontalorverticaldeviationstomakethecontactsinalignmentandtomakegoodcontacts.Thecrevicesshouldbefilledwithgreasypasteandpainted.3.3.4.Thevoltagegradingandscreeningringsorcoversshouldbeinstalledcorrectlyandfirmly.3.4.Installationandadjustmentofthetransmissiondevicesshouldconformtofollowingrequirements:3.4.1.Innerdiameterofthepullrodsshouldmatchwithshaftdiameteroftheoperatingmechanismandgapbetweentherodandtheshaftshouldnotbegreaterthan1mm.Thepinsforconnectionsshouldnotbecomeloosened.3.4.2.Aprotectingringshouldbeinstalledifapullroddamageorbreakagemaycauseittobeincontactwithaliveconductingpartsandthuscausingafault.3.4.3.Transmissionpartssuchasprolongedshafts,bearings,couplings,mediumshaftbearings,cornerarmsandetc.shouldbeinstalledintheircorrectpositionandfixedfirmly.Transmissiongearsshouldmatchcorrectlyandtheiroperationiseasyandfree.3.4.4.Positioningscrewsshouldbeadjustedaccordingtotechnicalrequirementsfortheproductsandthenfixed.3.4.5.Lubricatinggreasesuitableforlocalclimateshouldbeappliedtoalltransmissionparts.3.4.6.Turningorpullingspringsonthegroundingknifesshouldbetoadjustedthatoperatingmomentisminimumandthenfixed.Blackpaintisappliedtotheverticalconnectingrods.3.5.Installationandadjustmentoftheoperatingmechanismshouldconformtofollowingrequirements:3.5.1.Operatingmechanismsshouldbeinstalledfirmly.Installationpositionsoftheoperatingmechanismonasameaxiallineshouldbeidentical.3.5.2.Manymanualopeningandclosingoperationshouldbeperformedfirstlybeforemakinganelectricorapneumaticoperationandtheoperatingmechanismsshouldoperatecorrectly.3.5.3.Rotatingdirectionofthemotorshouldbecorrectandindicationofthepositionshouldconformtotheactualopeningorclosingpositionoftheequipment.3.5.4.Operatingmechanismsshouldoperatesteadily,noblocking,impactorabnormalphenomena.3.5.5.Positionlimitingdeviceshouldoperatecorrectlyandreliably.Electricorgassupplyshouldbecutoffreliablywhenreachingstipulatedopeningorclosinglimitingposition.3.5.6.Joints,valves,hepipelinesshouldnothaveseepageorleakage.3.5.7.Sealpadsonthemechanismboxesshouldbetight.3.6.Relativepositionsandsparetravelsofthecontactsinclosingpositionoftheisolatedswitchesandcleardistancesbetweenthecontactsinopeningpositionarecorrect.3.7.Arcingcontactsshouldmakebeforethemaincontactswhenclosetheisolatedswitcheswitharcingcontactsandbreakafterthemaincontactswhenopenthem.3.8.Thenon-simultaneityofcontactsforthreephaseunitedoperationshouldconformtostipulationasshownintable3.8orinaccordancewithspecificationsoftheproducts.Table3.8.:Permissiblenon-simultaneitylimitingvalveforthreephaseisolatedswitchesVoltage(kV)Difference(mm)10~35563~13210220~400203.9.Conductingpartsoftheisolatingswitchesshouldconformtofollowingstipulations:3.9.1.A0.05mm×10mmfeelergagecan’tgetinlinecontactsurfaces,andinsertingdepthofthefeelergageshouldnotexceed4mmfor50mmwidthorlessofcontactsurfacesand6mmfor60mmandmorewidths.3.9.2.Thecontactsshouldtouchtightlyeachother,andcontactpressureontwosidesshouldbeuniformandconformtotechnicalstipulationoftheproducts.3.9.3.Thecontactsurfacesshouldbewellflat,cleanandpastedwithathinlayerofneutralvaseline.Flexiblejointersofconductivepartsshouldnothavebentdamage,andconnectionsshouldbefirmandformatightcontact.Noseriousconcaveorcorrosionspotsonsurfacesoftheconductingparts.3.9.4.Applyathinlayerofelectriccompoundgreaseonterminalsurfacesoftheequipment.3.10.Interlockdevicesoftheisolatedswitchesshouldoperatefreely,accuratelyandreliably.Mechanicalorelectricalinterlocksbetweengroundingknifeandmaincontactfortheisolatedswitcheswithagroundingknifeshouldbecorrectandreliable.3.11.Installauxiliaryswitchesoftheisolatedswitchesfirmly,operationisaccurateandcontactistight.Theirmountingpositionshouldbeeasilyaccessibleforinspection.Providerain-proofmeasureswheninstalloutdoorswitches.3.12.Manualoperatedgroundingswitchesshouldoperatefreelyandreliablyandtheirclosingtimeshouldmeetrequirementsoftheprotectionrelay.Examinethebufferscarefully,andtheircompressivetravelmightconformtorequirementsoftheproducts.3.13.Qualitystandardsforinstallandregulatetheisolatedswitchesareasshownintable3.13.Table3.13.:InstallationandregulationoftheisolatedswitchesExaminationitemsPropertyQualitystandardsMethodsandtoolsforexaminationInstallationoftheporcelainpostsExaminationofappearanceMainClean,withoutcrackInspectionExaminationofadhesionbetweenporcelainandironMainFirmBoltsforconnecttheporcelainpostsandtheoperationshaftsonbaseplanesTightCheckbyawrenchVisualexaminationofthevoltageequalizingringsClean,withoutdamageanddeformationInspectionConductivepartsExaminationofflexiblesoftconnectionReliable,withoutdamagePullExaminationofthewiringterminalsMainCleanandneat,coatelectriccompoundgreaseInspectionExaminationofcontactpartsSilverplatedlayeronthecontactsurfacesPerfect,withoutpeelInspectionLinecontactMainCan’tsqueezeinCheckbya0.05mm×10mmfeelergageContactwidth≤50mmMainDepthsqueezingingap≤4mmContactwidth≥60mmMainDepthsqueezingingap≤6mmTransmissionequipmentTransmissioncomponentsInstallationofthecomponentsCorrectconnection,solidfixtureInspectionOperationexaminationAccurate,flexibleandeasyOperateRegulationofthepositionboltsMainReliable,inflectionarmexceednotdeadpointOperateExaminationoftheauxiliaryswitchesReliableoperation,tightcontactOperateMechanicalorelectricalinterlockbetweenthegroundingknifeandthemaincontactMainAccurateandreliableTestOperationexaminationforthepositionlimitingdevicesMainTripoffpowersupplyreliablyatopeningorclosinglimitpositionsOperateExaminationofthesealpadsinthemechanismboxesCompleteInspectionRegulationoftheisolatedswitchesClosingstatusRelativepositionofthecontactsMainInaccordancewithmanufacturestipulationCheckdependonmanufacturestipulationSparetravelContactpressureattwosidesofthecontactsMainCleardistanceandanglebetweenthecontactsinopeningconditionMainInaccordancewithmanufacturestipulationCheckdependonmanufacturestipulationNon-simultaneityofcontactsforthreephaseunitedoperationOperationsequenceofthearc-contactsandthemaincontactsCorrectOperateInterlocktestingoftheisolatedswitchesandtheoperationmechanismsMainSteadyoperation,withoutblockEarthEarthofthebasesFirmandconductivePullandconductanceexaminationEarthofthemechanismboxesExaminationoftheanti-loosepartsMainTightanti-loosenuts,openforelocksInspectionMarkofphasecolorCorrectandclearTreatmentofholesTightseal4.Test4.1.Measureinsulationresistancesoftheorganictransmissionrods.Measuredinsulationresistancesmustbehigherthanstandardvaluesasshownintable4.1.Table4.1.:StandardinsulationresistancesoftheorganictransmissionrodsRatedvoltage(kV)3~1520~3563~220330~500Standardinsulationresistance(MΩ)120030006000100004.2.MeasureDCresistancesoftheisolatedswitchesinaccordancewithtechnicalstipulationsoftheproducts.4.3.Carryout1min.50HzACvoltagewithstandingtestsandtestvoltagestandardsareasshownintable4.3.Table4.3.:TestvoltagestandardsofACvoltagewithstandingtestRatedvoltage(kV)6.62033132220Standardtestvoltage(kV)33.56895.73024504.4.Minimumoperationvoltageofthecoilsintheoperationmechanismsshouldconformtostipulationsofthemanufactories.4.5.Mainknifesandgroundingknifesoftheisolatedswitchesmustbeopeningorclosingreliablywhentheirvoltagesorpneumaticpressuresareinfollowingranges:4.5.1.Thevoltageonterminalsofthemotorformotoroperationmechanismisinrangeof80%~110%oftheratedvoltage.4.5.2.Thepneumaticpressureofpressedairintheoperationmechanismisinrangeof85%~110%oftheratedpneumaticpressure.4.5.3.Thevoltageonterminalsofsecondarycontrolandelectromagneticinterlockcoilsisinrangeof80%~110%oftheratedvoltage.4.6.Testrecordsforisolatedswitchesareasshownintable4.6.Table4.6.:TestrecordsoftheisolatedswitchesProjectnameTypeRatedvoltage(kV)Ratedcurrent(A)Ratedfrequency(Hz)OperationmechanismOperationmannerManufactoryManufacturenumberManufacturedateTestitemsStandardsResultsRemarkInsulationresistancesAphaseBphaseCphaseDCresistancesoftheconductivecircuitsAphaseBphaseCphaseACvoltagewithstandtestsAphasetoB,CphasesandgroundBphasetoC,AphasesandgroundCphasetoA,BphasesandgroundTestingofminimumvoltageofcoilsinoperationmechanismTestingoftheoperationmechanismTestconclusionRepresentativeoftestersSignatureDate5.Puttingintoservice5.1.Generaldescription5.1.1Whenfinishedwiththeoriginalinstallationandallmodifications,conductacompleteoperationtestontheentireinstallationtoverifycompliancewithapplicablestandards.Testingshouldbeconductedbyafactory-trainedtechnicianinthepresenceofarepresentativeofthemanufacturerandtheowner’srepresentative.Followproceduresoutlinedintherelatedstandard.5.1.2.Periodictestingandservicingofthesystem,alldevices,andanyotherassociatedequipmentisessentialtoensureproperandreliableoperation.Testandservicethesystemandthedeviceaccordingtotheschedulesandproceduresoutlinedinthemanufacturer’smanuals.5.1.3.Betweenformalperiodictestingandservicingintervals,therelatedoperationchecksshouldbeperformedfordefiniteperiod,orfrequentlywhenrequiredbytheowner.5.2.Regulationrecordsoftheisolatedswitchesareasshownintable5.2.Table5.2.:RegulationoftheisolatedswitchesProjectnameTypeRatedvoltage(kV)Ratedcurrent(A)Ratedfrequency(Hz)OperationmechanismOperationmannerManufactoryManufacturenumberManufacturedateRegulationitemsPermittedvalueMeasuredvalueRemarkClearancebetweeninnerdiametersofthepullingrodsanddiametersoftheoperationmechanismshafts(mm)≤1mmErrorofdistancesbetweenphases(mm)BetweenA-BphasesBetweenB-CphasesRegulationofthecontactsInserteddepthsofthemovingcontacts(mm)AphaseBphaseCphaseSparetravels(mm)AphaseBphaseCphaseClearancesbetweenthecontactsinopencondition(mm)AphaseBphaseCphaseNon-simultaneity(mm)AphaseBphaseCphaseExaminationconclusionAcceptanceopinionsSignatureDateConstructiongroupConstructionteamQualitydepartmentSupervisorydepartment6.Safetyprecautions6.1.Theinstallationhastobecarriedoutbyqualifiedpersonalfollowingtheinstructionofthemaker.Onlyqualified,authorizedpersonsshouldcarryoutelectricalwork.Wiringshouldbeperformedbythequalifiedpersonnelonly.6.2.Adisconnectswitchmustbeinstalledtobreakallcurrentcarryingconductors.Beforemakinganyelectricalconnectionensurethatthemainswitchisoff,alloftheelectricalpowerlinestotheequipmentmustbeisolated.Failuretoobservethisprecautionmayresultinseriouspersonalinjury.6.3.Allmainscablesandsignalcablesmustbeconnectedinexactaccordancewiththeoperatinginstructionstoavoidtheriskofelectricshock.6.4.Whilethedevicesarepowered,apotentiallylethalshockhazardexistsinsidethedevices.Donotopenthedeviceswhilethedevicesarepowered.6.5.Theinstrumentmustbegroundedorearthed.6.6.Iftheapparatusisdamagedoritislikelytheprotectionhasbeenimpaired,theapparatusshouldbeswitchedoffandsecuredagainstunintendeduse.6.7.Mustcarryoutfollowingprocedurebeforemaintenance
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 二零二五年度房屋财产分割及共有权转让协议3篇
- 课程设计游标卡尺
- 2025年销售年终工作总结参考(三篇)
- 二零二五年度创业投资对赌协议书范本及退出机制
- 二零二五年度建筑水暖消防工程监理分包合同2篇
- 市场总监主要职责模版(2篇)
- 课程设计医疗急救
- 2025年牛津上海版高二地理下册阶段测试试卷
- 2025年人教版七年级物理上册阶段测试试卷
- 2025版顶楼物业买卖合同书3篇
- 2023年公务员体检表
- YY/T 0882-2013麻醉和呼吸设备与氧气的兼容性
- JJG 596-2012电子式交流电能表
- GB/T 5237.1-2017铝合金建筑型材第1部分:基材
- GB/T 2317.1-2000电力金具机械试验方法
- 供应商ROHs审核表
- 五大发电公司及所属电厂列表及分部精编版
- 小学数学听课记录 精选(范文20篇)
- 光伏电站设备监造与性能验收
- 10kV架空线路施工方案
- 2018江苏苏州中考英语真题解析
评论
0/150
提交评论