1、外文文献introduction to dc machines the transformer on loaddc machines are characterized by their versatility. by means of various combination of shunt, series, and separately excited field windings they can be designed to display a wide variety of volt-ampere or speed-torque characteristics for both dy

2、namic and steady state operation. because of the ease with which they can be controlled , systems of dc machines are often used in applications requiring a wide range of motor speeds or precise control of motor output.the essential features of a dc machine are shown schematically. the stator has sal

3、ient poles and is excited by one or more field coils. the air-gap flux distribution created by the field winding is symmetrical about the centerline of the field poles. this axis is called the field axis or direct axis.as we know , the ac voltage generated in each rotating armature coil is converted

4、 to dc in the external armature terminals by means of a rotating commutator and stationary brushes to which the armature leads are connected. the commutator-brush combination forms a mechanical rectifier, resulting in a dc armature voltage as well as an armature m.m.f. wave which is fixed in space.

5、the brushes are located so that commutation occurs when the coil sides are in the neutral zone , midway between the field poles. the axis of the armature m.m.f. wave then in 90 electrical degrees from the axis of the field poles, i.e., in the quadrature axis. in the schematic representation the brus

6、hes are shown in quarature axis because this is the position of the coils to which they are connected. the armature m.m.f. wave then is along the brush axis as shown. (the geometrical position of the brushes in an actual machine is approximately 90 electrical degrees from their position in the schem

7、atic diagram because of the shape of the end connections to the commutator.)the magnetic torque and the speed voltage appearing at the brushes are independent of the spatial waveform of the flux distribution; for convenience we shall continue to assume a sinusoidal flux-density wave in the air gap.

8、the torque can then be found from the magnetic field viewpoint. the torque can be expressed in terms of the interaction of the direct-axis air-gap flux per pole and the space-fundamental component of the armature m.m.f. wave . with the brushes in the quadrature axis, the angle between these fields i

9、s 90 electrical degrees, and its sine equals unity. for a p pole machine in which the minus sign has been dropped because the positive direction of the torque can be determined from physical reasoning. the space fundamental of the sawtooth armature m.m.f. wave is 8/ times its peak. substitution in a

10、bove equation then gives where =current in external armature circuit; =total number of conductors in armature winding; =number of parallel paths through winding;and is a constant fixed by the design of the winding.the rectified voltage generated in the armature has already been discussed before for

11、an elementary single-coil armature. the effect of distributing the winding in several slots is shown in figure ,in which each of the rectified sine waves is the voltage generated in one of the coils, commutation taking place at the moment when the coil sides are in the neutral zone. the generated vo

12、ltage as observed from the brushes is the sum of the rectified voltages of all the coils in series between brushes and is shown by the rippling line labeled in figure. with a dozen or so commutator segments per pole, the ripple becomes very small and the average generated voltage observed from the b

13、rushes equals the sum of the average values of the rectified coil voltages. the rectified voltage between brushes, known also as the speed voltage, is where is the design constant. the rectified voltage of a distributed winding has the same average value as that of a concentrated coil. the differenc

14、e is that the ripple is greatly reduced. from the above equations, with all variable expressed in si units: this equation simply says that the instantaneous electric power associated with the speed voltage equals the instantaneous mechanical power associated with the magnetic torque , the direction

15、of power flow being determined by whether the machine is acting as a motor or generator.the direct-axis air-gap flux is produced by the combined m.m.f. of the field windings, the flux-m.m.f. characteristic being the magnetization curve for the particular iron geometry of the machine. in the magnetiz

16、ation curve, it is assumed that the armature m.m.f. wave is perpendicular to the field axis. it will be necessary to reexamine this assumption later in this chapter, where the effects of saturation are investigated more thoroughly. because the armature e.m.f. is proportional to flux times speed, it

17、is usually more convenient to express the magnetization curve in terms of the armature e.m.f. at a constant speed . the voltage for a given flux at any other speed is proportional to the speed,i.e. figure shows the magnetization curve with only one field winding excited. this curve can easily be obt

18、ained by test methods, no knowledge of any design details being required.over a fairly wide range of excitation the reluctance of the iron is negligible compared with that of the air gap. in this region the flux is linearly proportional to the total m.m.f. of the field windings, the constant of prop

19、ortionality being the direct-axis air-gap permeance.the outstanding advantages of dc machines arise from the wide variety of operating characteristics which can be obtained by selection of the method of excitation of the field windings. the field windings may be separately excited from an external d

20、c source, or they may be self-excited; i.e., the machine may supply its own excitation. the method of excitation profoundly influences not only the steady-state characteristics, but also the dynamic behavior of the machine in control systems.the connection diagram of a separately excited generator i

21、s given. the required field current is a very small fraction of the rated armature current. a small amount of power in the field circuit may control a relatively large amount of power in the armature circuit; i.e., the generator is a power amplifier. separately excited generators are often used in f

22、eedback control systems when control of the armature voltage over a wide range is required. the field windings of self-excited generators may be supplied in three different ways. the field may be connected in series with the armature, resulting in a shunt generator, or the field may be in two sectio

23、ns, one of which is connected in series and the other in shunt with the armature, resulting in a compound generator. with self-excited generators residual magnetism must be present in the machine iron to get the self-excitation process started.in the typical steady-state volt-ampere characteristics,

24、 constant-speed prime movers being assumed. the relation between the steady-state generated e.m.f. and the terminal voltage is where is the armature current output and is the armature circuit resistance. in a generator, is large than ; and the electromagnetic torque t is a countertorque opposing rot

25、ation. the terminal voltage of a separately excited generator decreases slightly with increase in the load current, principally because of the voltage drop in the armature resistance. the field current of a series generator is the same as the load current, so that the air-gap flux and hence the volt

26、age vary widely with load. as a consequence, series generators are not often used. the voltage of shunt generators drops off somewhat with load. compound generators are normally connected so that the m.m.f. of the series winding aids that of the shunt winding. the advantage is that through the actio

27、n of the series winding the flux per pole can increase with load, resulting in a voltage output which is nearly constant. usually, shunt winding contains many turns of comparatively heavy conductor because it must carry the full armature current of the machine. the voltage of both shunt and compound

28、 generators can be controlled over reasonable limits by means of rheostats in the shunt field. any of the methods of excitation used for generators can also be used for motors. in the typical steady-state speed-torque characteristics, it is assumed that the motor terminals are supplied from a consta

29、nt-voltage source. in a motor the relation between the e.m.f. generated in the armature and the terminal voltage is where is now the armature current input. the generated e.m.f. is now smaller than the terminal voltage , the armature current is in the opposite direction to that in a motor, and the e

30、lectromagnetic torque is in the direction to sustain rotation of the armature.in shunt and separately excited motors the field flux is nearly constant. consequently, increased torque must be accompanied by a very nearly proportional increase in armature current and hence by a small decrease in count

31、er e.m.f. to allow this increased current through the small armature resistance. since counter e.m.f. is determined by flux and speed, the speed must drop slightly. like the squirrel-cage induction motor ,the shunt motor is substantially a constant-speed motor having about 5 percent drop in speed fr

32、om no load to full load. starting torque and maximum torque are limited by the armature current that can be commutated successfully.an outstanding advantage of the shunt motor is ease of speed control. with a rheostat in the shunt-field circuit, the field current and flux per pole can be varied at w

33、ill, and variation of flux causes the inverse variation of speed to maintain counter e.m.f. approximately equal to the impressed terminal voltage. a maximum speed range of about 4 or 5 to 1 can be obtained by this method, the limitation again being commutating conditions. by variation of the impress

34、ed armature voltage, very wide speed ranges can be obtained.in the series motor, increase in load is accompanied by increase in the armature current and m.m.f. and the stator field flux (provided the iron is not completely saturated). because flux increases with load, speed must drop in order to mai

35、ntain the balance between impressed voltage and counter e.m.f.; moreover, the increase in armature current caused by increased torque is smaller than in the shunt motor because of the increased flux. the series motor is therefore a varying-speed motor with a markedly drooping speed-load characterist

36、ic. for applications requiring heavy torque overloads, this characteristic is particularly advantageous because the corresponding power overloads are held to more reasonable values by the associated speed drops. very favorable starting characteristics also result from the increase in flux with incre

37、ased armature current.in the compound motor the series field may be connected either cumulatively, so that its.m.m.f.adds to that of the shunt field, or differentially, so that it opposes. the differential connection is very rarely used. a cumulatively compounded motor has speed-load characteristic

38、intermediate between those of a shunt and a series motor, the drop of speed with load depending on the relative number of ampere-turns in the shunt and series fields. it does not have the disadvantage of very high light-load speed associated with a series motor, but it retains to a considerable degr

39、ee the advantages of series excitation.the application advantages of dc machines lie in the variety of performance characteristics offered by the possibilities of shunt, series, and compound excitation. some of these characteristics have been touched upon briefly in this article. still greater possi

40、bilities exist if additional sets of brushes are added so that other voltages can be obtained from the commutator. thus the versatility of dc machine systems and their adaptability to control, both manual and automatic, are their outstanding features.外文翻译直流电机导论负载运行的变压器直流电机以其多功用性而形成了鲜明的特征。通过并励、串励和特励绕

41、组的各种不同组合,直流电机可设计成在动态和稳态运行时呈现出宽广范围变化的伏-安或速度-转矩特性。由于直流电机易于控制,因此该系统用于要求电动机转速变化范围宽或能精确控制电机输出的场合。定子上有凸极,由一个或一个以上励磁线圈励磁。励磁绕组产生的气隙通以磁极中心线为轴线对称分布,这条轴线称为磁场轴线或直轴。我们知道,每个旋转的电枢绕组中产生的交流电压,经由一与电枢连接的旋转的换向器和静止的电刷,在电枢绕组出线端转换成直流电压。换向器一电刷的组合构成机械整流器,它产生一直流电枢电压和一在空间固定的电枢磁势波形。电刷的放置应使换向线圈也处于磁极中性区,即两磁极之间。这样,电枢磁势波形的轴线与磁极轴线相

42、差90°电角度,即位于交轴上。在示意图中,电刷位于交轴上,因为此处正是与其相连的线圈的位置。这样,如图所示电枢磁势波的轴线也是沿着电刷轴线的。(在实际电机中,电刷的几何位置大约偏移图例中所示位置90°电角度,这是因为元件的末端形状构成图示结果与换向器相连。)电刷上的电磁转矩和速度电压与磁通分布的空间波形无关;为了方便起见,我们假设气隙中仍然是正弦磁密波,这样便可以从磁场分析着手求得转矩。转矩可以用直轴每极气隙磁通和电枢磁势波的空间基波分量相互作用的结果来表示。电刷处于交轴时,磁场间的角度为90°电角度,其正弦值等于1,则对于一台p极电机 式中由于转矩的正方向可以根

43、据物理概念的推断确定,因此负号已经去掉。电枢磁势锯齿波的空间基波是峰值的8/。上式变换后有 式中 =电枢外部电路中的电流; =电枢绕组中的总导体数; =通过绕组的并联支路数;且 其为一个由绕组设计而确定的常数。简单的单个线圈的电枢中的整流电压前面已经讨论过了。将绕组分散在几个槽中的效果可用图形表示,图中每一条整流的正弦波形是一个线圈产生的电压,换向线圈边处于磁中性区。从电刷端观察到的电压是电刷间所有串联线圈中整流电压的总和,在图中由标以的波线表示。当每极有十几个换向器片,波线的波动变得非常小,从电刷端观察到的平均电压等于线圈整流电压平均值之和。电刷间的整流电压即速度电压,为 式中为设计常数。分

44、布绕组的整流电压与集中线圈有着相同的平均值,其差别只是分布绕组的波形脉动大大减小。将上述几式中的所有变量用si单位制表达,有 这个等式简单地说明与速度电压有关的瞬时功率等于与磁场转矩有关的瞬时机械功率,能量的流向取决于这台电机是电动机还是发电机。直轴气隙通由励磁绕组的合成磁势产生,其磁通-磁势曲线就是电机的具体铁磁材料的几何尺寸决定的磁化曲线。在磁化曲线中,因为电枢磁势波的轴线与磁场轴线垂直,因此假定电枢磁势对直轴磁通不产生作用。这种假设有必要在后述部分加以验证,届时饱和效应会深入研究。因为电枢电势与磁通成正比,所以通常用恒定转速下的电枢电势来表示磁化曲线更为方便。任意转速时,任一给定磁通下的

45、电压与转速成正比,即 图中表示只有一个励磁绕组的磁化曲线,这条曲线可以很容易通过实验方法得到,不需要任何设计步骤的知识。在一个相当宽的励磁范围内,铁磁材料部分的磁阻与气隙磁阻相比可以忽略不计,在此范围内磁通与励磁绕组总磁势呈线性比例,比例常数便是直轴气隙磁导率。直流电机的突出优点是通过选择磁场绕组不同的励磁方法,可以获得变化范围很大的运行特性。励磁绕组可以由外部直流电源单独激磁,或者也可自励,即电机提供自身的励磁。励磁防哪个法不仅极大地影响控制系统中电机的静态特性,而且影响其动态运行。他励发电机的连接图已经给出,所需励磁电流是额定电枢电流的很小一部分。励磁电路中很小数量的功率可以控制电枢电路中相对很大数量的功率,也就是说发电机是一种功率放大器。当需要在很大范围内控制电枢电压时,他励发

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论