1、不同环境温度下载流量修正系数导体工作温度(C)环境温度 (C)(空气中)101520253035404550501.701.621.521.421.321.221.000.75-601.581.501.411.321.221.111.000.860.73651.481.411.341.261.181.091.000.890.77701.411.351.291.221.151.081.000.910.81801.321.271.221.171.111.061.000.930.86901.261.221.181.141.091.041.000.940.89不同环境温度下载流量修正系数导体工作温度(
2、C)环境温度 (C)(土壤中)101520253035501.261.181.101.000.890.77601.201.131.071.000.930.85651.171.121.061.000.940.88701.151.111.051.000.940.88801.131.091.041.000.950.90901.111.071.041.000.960.92电缆在空气中并列敷设时载流量修正系数根数载 流 量 修 正 系 数1236468912S=1d1.000.900.850.800.820.80-S=2d1.000.980.900.950.900.850.800.80S=3d1.001
3、.000.980.980.980.900.850.85不同土壤热阻系数的载流量修正系数电压(KV)截面范围(mm2)土壤热阻系数 T =( C- M/W )0.81.01.21.51.82.0.53.0135及以下50120150300400及以上1.061.000.950.890.840.810.750.711.081.000.940.870.800.770.700.651.081.000.930.860.790.760.690.641.091.000.930.850.790.760.680.631035及以下50120150300400及以上1.051.000.950.900.840.82
4、0.760.701.061.000.940.880.820.800.730.681.071.000.940.870.810.780.710.661.071.000.930.870.810.770.710.65电线电缆穿管敷设于空气中载流量修正系数(参考值)穿管根数修正系数240.80580.609120.5012以上0.45注:1、穿管电缆根数系指有负荷且发热的导线根数。中性线或保护线可不计。 2、一般情况下,穿管根数体积占管内体积的40%左右。 3、当管子并列敷设时乘以0.95的修正系数。三芯或三个单芯电缆平行成组直埋于土壤中载流量修正系数(参考值)电缆间距组数23456相互接触 70100
5、(mm)220250(mm)0.790.6690.630.580.550.850.750.680.640.600.870.970.750.720.69电缆在桥架上无间距配置多层并列时持续载流量的校正系数叠置电缆层数水平排列1234梯 架0.800.660.550.50托 盘0.700.550.500.45不同埋地深度时载流量修正系数电压(KV)深度L(mm)修 正 系 数L=7001.001.00700 L =10000.970.981000 L =12500.950.961250 L =12修正系数0.800.600.500.45桥架修正系数叠置层数1234梯 架0.800.650.550.
6、50托 盘0.700.550.500.45BV、BLV型绝缘线穿半硬塑料管、波纹管管径选择 单位:mm导线截面(mm2) 导 线 根 数234567891011121.01.51620252.52532420625324010324050162540506335505063709563120注: 半硬塑料管、波纹管的公称管径指外径。BV、BLV型绝缘线穿电线管管径选择 单位:mm 导线截面 (mm2)导 线 根 数 234567891011121.0191.51619252.519419625323810385116323825385164355051647670956476120150185
7、76 注: 1.电线管的管径指外径。 2.电线管规格根据GB3640-83。BV、BLV型绝缘线穿钢管管径选择 单位:mm导线截面(mm2)导 线 根 数234567891011121.01.515202.546202510253240162540253240503550504065705065658095120658010015080185240100 注: 1.钢管的管径指内径。 2.钢管规格根据GB3092-82低压流体输送用焊接钢管。BV、BLV型绝缘线穿硬塑料管(轻型)管径选择 单位:mm导线截面(mm2)导 线 根 数234567891011121.0201.51620252.54
8、253262032401025324050162532405063354050635070509512063150注: 硬塑料管(轻型)的公称管径指外径。BV、BLV型绝缘线穿硬塑料管(重型)管径选择 单位:mm导线截面(mm2)导 线 根 数234567891011121.01.51620252.542025326324010253240501625405035505070 注: 硬塑料管(重型)的管径指外径。BX、BLX型绝缘线穿半硬塑料管、波纹管管径选择 单位:mm导线截面(mm2)导 线 根 数234567891011121.01.5202532402.5425324065010325
9、063162540633550506370注: 半硬塑料管、波纹管的管径指外径。BX、BLX型绝缘线穿硬塑料管(轻型)管径选择 单位:mm导线截面(mm2)导 线 根 数234567891011121.01.52025322.54324061025324050162540506335505063709563120注: 硬塑料管(轻型)的管径指外径。BX、BLX型绝缘线穿硬塑料管(重型)管选择 单位(mm)导线截面(mm2)导 线 根 数234567891011121.01.52025322.542563240501032405016254050355050注: 硬塑料管(重型)的公称管径指外径
10、。电力电缆穿金属最小管径VVVLV0.6/1KV电缆标称截面(MM2)1.52.54610162535507095120150185焊接钢管(SC)或水煤气钢管(RC)最 小 管 径 (mm)电缆穿管长度在30m及以下直线20253240507080一个弯曲时2532507080100二个弯曲时3240507080100125YJVYJLV0.6/1KV电缆标称截面(MM2)1.52.54610162535507095120150185焊接钢管(SC)或水煤气钢管(RC)最 小 管 径 (mm)电缆穿管长度在30m及以下直线15202532405070一个弯曲时1520253240507080
11、二个弯曲时3220253240507080ZQDZLQD0.6/1KV电缆标称截面(MM2)162535507095120150185240焊接钢管(SC)或水煤气钢管(RC)最 小 管 径 (mm)电缆穿管长度在30m及以下直线3240507080一个弯曲时40507080100二个弯曲时507080100125注:适用于三芯、三芯+N及四芯等截面电力电缆。电力电缆穿聚氯乙烯管最小管径VVVLV0.6/1KV电缆标称截面(MM2)1.52.54610162535507095120聚氯乙烯硬质电线管(PC)最 小 管 径 (mm)电缆穿管长度在30m及以下直线202532405063一个弯曲时
12、202532405063二个弯曲时2532405063YJVYJLV0.6/1KV电缆标称截面(MM2)1.52.54610162535507095120聚氯乙烯硬质电线管(PC)最 小 管 径 (mm)电缆穿管长度在30m及以下直线202532405063一个弯曲时202532405063二个弯曲时2532405063ZQDZLQD0.6/1KV电缆标称截面(MM2)162535507095120聚氯乙烯硬质电线管(PC)最 小 管 径 (mm)电缆穿管长度在30m及以下直线324050一个弯曲时32405063二个弯曲时405063注:适用于三芯、三芯+N及四芯等截面电力电缆。铠装电力电缆
13、穿金属管最小管径VV*VLV*0.6/1KV电缆标称截面(MM2)1.52.54610162535507095120150185焊接钢管(SC)或水煤气钢管(RC)最 小 管 径 (mm)电缆穿管长度在30m及以下一个弯曲时25324050708080二个弯曲时253240507080100*:适用于 VV22,32,43 , VLV22,32,43YJV*YJLV*0.6/1KV电缆标称截面(MM2)1.52.54610162535507095120150185焊接钢管(SC)或水煤气钢管(RC)最 小 管 径 (mm)电缆穿管长度在30m及以下一个弯曲时2532405070100二个弯曲时
14、2532405070801008.7/10KV一个弯曲时80100125二个弯曲时100125*:适用于 YJV22,32, YJLV22,32ZQD*ZLQD*0.6/1KV电缆标称截面(MM2)162535507095120150185焊接钢管(SC)或水煤气钢管(RC)最 小 管 径 (mm)电缆穿管长度在30m及以下一个弯曲时7080100二个弯曲时70801008.7/10KV一个弯曲时80100125二个弯曲时100125*:适用于ZQD02,03,22,23,32,33,41 , VLV02,03,22,23,32,33,41注:适用于三芯、三芯+N及四芯等截面电缆穿墙保护管。控
15、制电缆穿金属管或聚氯乙烯硬质管最小管径电缆截面(MM2)控制电缆芯数2456,7810121416192430370.751.0焊接钢管(SC)或水煤气钢管(RC)最 小 管 径(mm)电缆穿管长度在30m及以下直 通1520253240一个弯曲时202532405070二个弯曲时2532405070电缆截面(MM2)焊接钢管(SC)或水煤气钢管(RC)最 小 管 径 (mm)1.52.5电缆穿管长度在30m及以下直 通2025324050一个弯曲时202532405070二个弯曲时253240507080100电缆截面(MM2)聚氯乙烯硬质电线管(PC)最 小 管 径 (mm)0.751.0
16、电缆穿管长度在30m及以下直 通2025324050一个弯曲时2532405063二个弯曲时32405063电缆截面(MM2)聚氯乙烯硬质电线管(PC)最 小 管 径 (mm)1.52.5电缆穿管长度在30m及以下直 通2532405063一个弯曲时32405063二个弯曲时32405063注:适用于KVV KXV KYV型控制电缆。电线电缆穿管最小管径管材种类导线规格型号电 话 支 线 穿 管 对 数123456789最 小 管 径 (mm)导线穿电线管(TC)或聚氯乙烯管(PC)RVB-2X0.22X0.516202532RVS-2X0.22X0.520253240导线穿焊接钢管(SC)或
17、水煤气钢管(RC)RVB-2X0.22X0.5152025RVS-2X0.22X0.515202532导线根数123456管材种类TC SCPC RCTC SCPC RCTC SCPC RCTC SCPC RCTC SCPC RCTC SCPC RC导线型号导 线 穿 管 最 小 管 径 (mm)RVVP- 2X0.22X0.516 1520 1525 2032 2032 2532 32同轴电缆根数12345管材种类TC SCRCTC SCRCTC SCRCTC SCRCTC SCRC同轴电缆型号规格电 缆 穿 管 最 小 管 径 (mm)SYV-SS-75-5-416 1525 2025 2
18、032 2540 3275-7-425 2032 2540 3250 4050 5075-9-425 2540 3250 4050 50- 50导线载流量型号BLV额定电压(KV)0.45/0.75导体工作温度(C)70环境温度(C)303540303540导线排列O-S-O-S-O导线根数245891212 以上245891212 以上245891212 以上标称截面(mm2)明敷载流量(A)导线穿管敷设载流量(A)2.524232113108713987129764323028181411101612109161210964139362418151322171412211513111056
19、534933252119312319172921181616767166473529264332272440302522251049790654840366045373355413431351271191108160504574564642695143385015514613599746256916857518463524770201189175127957971117887366108816760952472322151601201009014811192831361028576120288270250189141118106174131109981601201009015033431329
20、0217162135122200150125112184138115103185385362335254191159143235176147132216162135121240460432400307230191172283212177159260195162146注:明敷载流量值系根据 S2De(De-电线外径)计算型 号BLX额定电压(KV)0.45/0.75导体工作温度(C)65环境温度(C)303540303540导线排列O-S-O-S-O-导线根数-245891212 以上245891212 以上245891212 以上标称截面(mm 2)导线穿管敷设载流量(A)2.52523211
21、310871398712976433312818141110171311101612109641383524181513221714122115131110575248332420183023191728211715167771654533282541312623382924212510395876247393557433632533933293512411410577574843715344406549413750153142130947159538765544980605045701951801651229276691138470631047865589524222320515111394
22、85139104877812896807212028326224017913411210116512410393152114958515032530027520715512911619214412010817613211099185378349320241180150135222167139125204153127114240454420385293219183164270203169152248186155139注:明敷载流量值系根据S2De(De-电线外径)计算型 号BV-105额定电压(KV)0.45/0.75导线排列OOOO-S-O-S-O导体工作温度(C)105环境温度(C)3035
23、40303540标称截面(mm2)明 敷0.751514142221201.01817172625241.52423223231302.532313044424144342405856546565452767370环境温度(C)303540导线根数245891212 以上245891212 以上245891212 以上标称截面(mm2)明 敷0.751297611876118761.01410981310871310871.51614121018131110171311102.52519161424181513241815134341821191625211932242018644332825
24、4332272441312623注:明敷载流量值系根据 S2De(De-电线外径)计算BV105型耐热聚氯乙烯绝缘铜芯电线的载流量(n=105) BV-105截面 (mm)明敷(A)2根穿管(A)管径(mm)3根穿管(A)管径(mm)3根穿管(A)管径(mm)50C55C60C65C50C55C60C65CGDG50C55C60C65CGDG50C55C60C65CGDG1.5252322211918171615161716151415161615141315162.5343230282725242315162523222115162321201915194474442403937353315
25、1934323028151931292826202566057545151484643202544413937202540383634202510898480757672686420256763605725325956535025321612311711110495908581253285817672253275716763323825165157149140127121114108323811310710296323810196918632(51)35205191185174160152144136323813813112411732(51)12612011310750(51)5026425
26、123822520219218217240(51)17917016115240(51)15915114313550(51)7031029528026424022821720450(51)21320319218150(51)19318417416465-9538036234332429227826424950-26224923622365-23322221019865-12044842740538234733131429665-31129628126565-27526124823465-15051949446944239938036034065-36234532730865-3203052892
27、7280-注 1.本电线的聚氯乙烯绝缘中加了耐热增塑剂,线芯允许工作温度可达105,适用于高温场所,但要求电线接头用焊接或绞接后表面锡 la处理。电线实际允许工作温度还取决于电线与电线及电器接头的允许温度,当接头允许温度为95时,表中数据应乘以0.92,85 时应乘以0.84。 2.BLV-105型铝芯耐热线的载流量可按表中的数据乘以0.78。 3.本表中载流量数据系编者经计算得出,仅供参考。型 号BVV BVVB额定电压(KV)0.30/0.50芯 数单、 双芯导体工作温度(C)70环境温度(C)303540导线根数245891212以上245891212以上245891212以上标称截面(
28、mm2)穿 管 敷 设1.5171311915111091411982.52317151322161412201513114302319172922181626201715639292522372823213426221910544134315138322947353027167355464168514338634740362597736154906857518463474036115867265108816761100756356型 号BVV BVVB额定电压(KV)0.30/0.50芯 数一 芯二 芯三 芯四 芯五 芯导体工作温度(C)70环境温度(C)303540303540303540
29、303540303540标称截面(mm2)明 敷1.0201817-131211-1.52524222119181817161615141514132.5353230292725242321232220211918445423938363332302830282628262465854504946434139363836333633311079756968645959555153504649464316-91857978736870666166625725-121113105105989194898289837735-14413512512711911011510810010910395型 号BV额定电压(KV)0.45/0.7
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 农业职业经理人管理技能试题及答案
- 福建事业单位考试卫生健康政策题及答案
- 重要审查系统分析师试题及答案
- 找到信心备战花艺师考试试题及答案
- 一年级道德与法治上册第一单元我是小学生啦老师您好教案未来版
- 调酒师饮品定价与利润计算试题及答案
- 七年级数学下册第10章轴对称平移与旋转10.3旋转10.3.3旋转对称图形教案新版华东师大版
- 2024秋三年级英语上册 Module 6 Unit 2 Whats this教学设计 外研版(三起)
- Unit 6 Is this your skirt Lesson 32(教学设计)-2023-2024学年人教精通版英语三年级下册
- 客运站使用协议
- 供水管道穿越天然气管道交叉施工方案
- 钢结构防火涂料的施工方案
- 培育壮大健康养老托育家政服务消费
- 三年级上册数学计算能力竞赛
- 国资委风险预警-47页PPT课件
- 冻干讲义(东富龙)
- 中药辐照灭菌技术指导原则Word版
- AAOS膝关节骨关节炎循证医学指南(第二版)
- 高血压危象抢救流程
- B类表(施工单位报审、报验用表)
- 阀门检验记录表
评论
0/150
提交评论