4.8.1污水的提升SewageTransfer一、排水泵和排水泵房DrainagePumpsandDrainagePumpHouses民用和公共建筑的地下室、人防建筑、消防电梯底部集水坑以及工业建筑内部标高低于室外地坪的车间和其他用水设备房间排放的污、废水,若不能自流排至室外检查井时,必须提升排出,以保持室内良好的环境卫生。Sewageandwastewaterdischargedfrombasements,civilairdefensebuildings,andsumpsatthebottomoffireelevatorsofcivilandpublicbuildings,workshopswithinternalelevationlowerthanoutdoorfloorsinindustrialbuildingsandotherwater-consumingequipmentroomsmustbeliftedfordischargetomaintaingoodindoorenvironmentalsanitationiftheycannotflowbygravitytooutdoorinspectionwells.一、排水泵和排水泵房DrainagePumpsandDrainagePumpHouses建筑内部污废水提升包括:Sewageandwastewatertransferinsidebuildingsinclude:01/02/污水集水池容积的确定Determinationofvolumeofsewagecatchbasin03/排水泵房的设计Designofdrainagepumphouses污水泵的选择Selectionofsewagepumps一、排水泵和排水泵房DrainagePumpsandDrainagePumpHouses1.排水泵DrainagePumps建筑内部污、废水抽升常采用潜水泵、液下泵,有时也可采用卧式泵。潜水泵和液下泵无需设置引水装置,直接浸没在水中运行,无噪声和振动,方便灵活,应优先选用。当选用卧式泵进行排水,必须选用污水泵,同时应设计成自灌式。Submersiblepumpsandsubmergedpumpsareusuallyusedforsewageandwastewatertransferinsidebuildings,andsometimeshorizontalpumpsarealsoused.Submersiblepumpsandsubmergedpumpsdonotneedtobeequippedwithwater-divertingdevices.Theyaredirectlyimmersedinwaterforoperationwithoutnoiseandvibration,andtheyareflexibleandconvenienttooperate,sotheyshallbepreferred.Whenhorizontalpumpsareusedfordrainage,sewagepumpsmustbeselectedanddesignedasanautomaticwater-fillingtype.潜水泵Submersiblepump液下泵Submergedpump一、排水泵和排水泵房DrainagePumpsandDrainagePumpHouses(1)排水泵的设置Settingofdrainagepump1)公共建筑内应以每个生活污水集水池为单元,其污水泵应设一台备用泵。地下室、设备机房、车库冲洗地面的排水,当有2台及2台以上排水泵时,可不设备用泵。Eachdomesticsewagecatchbasinshallbetakenasaunitinpublicbuildingsandthereshallbeastandbypumpforthesewagepump.Forthedrainageofwaterusedtoflushgroundinbasements,equipmentrooms,andgarages,standbypumpsmaynotbeprovidedwhentherearetwoormoredrainagepumps.2)污水泵宜独立运行,各水泵应有独立的吸水管。Sewagepumpsshallworkindependently,andeachpumpshallhaveanindependentsuctionpipe.3)潜水泵和液下泵在压水管上设阀门,自灌式卧式泵在吸水管上设阀门,以便于检修。Submersiblepumpsandsubmergedpumpsareprovidedwithvalvesonpressurizeddrainagepipeswhileautomaticwater-fillinghorizontalpumpsareprovidedwithvalvesonsuctionpipestofacilitatemaintenance.4)污水泵宜采用自动控制,当集水池不能设事故排出管时,污水泵应有不间断的动力供应。Thesewagepumpshallbeautomaticallycontrolled.Whenthecatchbasincannotbeequippedwithanaccidentdischargepipe,thesewagepumpshallhaveanuninterruptedpowersupply.5)污水泵宜设置排水管单独排至室外。Thesewagepumpshallbeprovidedwithadrainagepipetodischargewateroutdoorsseparately.6)2台及2台以上污水泵共用一条出水管时,应在每台污水泵出水管上装设阀门和止回阀,单台污水泵出水管会产生倒灌时也应设置止回阀。Whentwoormoresewagepumpsshareoneoutletpipe,valvesandcheckvalvesshallbeinstalledontheoutletpipeofeachsewagepump.Checkvalvesshallalsobeprovidedwhenbackflowoccursintheoutletpipeofasinglesewagepump.一、排水泵和排水泵房DrainagePumpsandDrainagePumpHouses水泵扬程应按提升高度、管路系统水头损失,另附加2m~3m流出水头计算。Thesewagepumpheadshallbedeterminedbycalculating.Itisthesumoffrictionalheadlossandlocalheadlossinsuctionpipesandpressurizedpipesandstaticheadsandbecalculatedwithanadditionaloverflowheadof2~3m.(2)排水泵扬程、流量的确定Determinationofdrainagepumpheadandflow扬程Head一、排水泵和排水泵房DrainagePumpsandDrainagePumpHouses室内污水水泵的流量应按生活排水设计秒流量选定。
Theflowofindoorsewagepumpsshallbedeterminedbasedonthedomesticdrainagedesignsecondflow.当室内设有生活污水处理设施并设置调节池时,污水水泵的流量可按生活排水最大小时流量选定。
Theflowofsewagepumpscanbedeterminedbasedonthemaximumdomesticdrainagehourlyflowwhentherearedomesticsewagetreatmentfacilitiesandregulatingtanksindoors.当地坪集水坑(池)接纳水箱(池)溢流水、泄空水时,应按水箱(池)溢流量、泄流量与排入集水池的其他排水量中大者选择水泵机组。
Whenthefloorcatchpit(basin)receivesoverflowanddischargewaterfromthetank(pool),thepumpunitshallbeselectedaccordingtothegreatestoftheoverflowanddischargeofthetank(pool)andotherdrainagevolumesdischargedintothepool.流量Flow一、排水泵和排水泵房DrainagePumpsandDrainagePumpHouses(1)设置位置Position应设在靠近集水池,通风良好的地下室或底层单独的房间内,以控制和减少对环境的污染。Theyshallbelocatednearthewatercollectingtank,inawell-ventilatedbasement,oraseparateroomonthegroundfloortocontrolandreduceenvironmentalpollution.不得设在对卫生环境有特殊要求的生产厂房和公共建筑内或有安静和防振要求房间的邻近。Theyshallnotbelocatednearorbelowproductionplantsandpublicbuildingswithspecialrequirementsforthesanitaryenvironmentornearroomswithquietandanti-vibrationrequirements.2.排水泵房Drainagepumphouse一、排水泵和排水泵房DrainagePumpsandDrainagePumpHouses(2)设置要求SettingRequirements排水泵房的位置应使室内排水管道和水泵出水管尽量简洁,并考虑维修检测的方便。Thedrainagepumproomshallbelocatedtomaketheindoordrainagepipesandwaterpumpoutletpipesassimpleaspossibleandconvenientformaintenanceandinspection.二、集水池的选择Selectionofcatchbasin1.设置位置Position在地下室最低层卫生间和淋浴间的底板下或邻近、地下室水泵房和地下车库内、地下厨房和消防电梯井附近。Itissetunderornearthebottomslaboftherestroomandshowerroomonthelowestfloorofthebasement,inthebasementpumproomandundergroundgarage,andneartheundergroundkitchenandfireelevatorshaft.2.集水池有效容积Effectivevolumeofcatchbasin集水池有效容积不宜小于最大一台污水泵5min的出水量,且污水泵每小时启动次数不宜超过6次。Theeffectivevolumeofthewatercollectingtankshallnotbelessthanthewateroutputofthelargestsewagepumpfor5minutes,andthesewagepumpshallnotbestartedmorethan6timesperhour.二、集水池的选择Selectionofcatchbasin3.设置要求Settingrequirements1集水池除满足有效容积外,还应满足水泵设置、水位控制器、格栅等安装、检查要求。Inadditiontomeetingtherequirementforeffectivevolume,thewatercollectingtankshallalsomeetthesettingrequirementsforthepumpaswellasinstallationandinspectionrequirementsforthewaterlevelcontroller,grille,etc.2集水池设计最低水位,应满足水泵吸水要求。Thedesignedminimumwaterlevelofthecatchbasinshallmeetthesuctionrequirementsforthepump.3集水坑应设检修盖板。Thecatchpitshallbeequippedwithanaccesscover.4集水池底宜有不小于0.05坡度坡向泵位;集水坑的深度及平面尺寸,应按水泵类型而定。Thebottomofthecatchbasinshallhaveaslopenotlessthan0.05tothepumpposition;thedepthandplanesizeofthecatchpitshallbedeterminedbasedontypesofthepump.二、集水池的选择Selectionofcatchbasin3.设置要求Settingrequirements5污水集水池宜设置池底冲洗管。Thebottomflushingpipeshallbesetupint
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2024停薪留职期间员工健康保障及医疗费用合同3篇
- 2025办公电脑采购合同范本办公电脑采购合同格式
- 2024墙体图文广告设计与户外广告投放策略合同3篇
- 托育转让合同模版
- 厂商纸牌购买合同模板
- 2024上海商业综合体物业服务管理合同3篇
- 2024年上海个人租房合同范本与房屋租赁纠纷处理机制2篇
- 2025合同协议土地流转合同补充协议
- 2025的劳务用工合同范本
- 2024年度船舶文化交流合作合同范本3篇
- 马来酸酐接枝聚丙烯
- PE管道焊接工艺卡
- 第四章分子的对称性
- (最新)专家服务基层工作培训会领导讲话(精)
- 苏州预防性试验、交接试验费用标准
- 最新【SD高达G世纪-超越世界】各强力机体开发路线
- 完整MAM-KY02S螺杆空压机控制器MODBUSⅡ通信协议说明
- 专业英语四级听力模拟题
- [广州]污水处理厂工程监理投标大纲(325页完整)_secret
- 南京禄口机场二期扩建工程项目融资分析报告(第一稿)
- 乡镇殡葬整治工作开展情况汇报
评论
0/150
提交评论