题目:大唐清苑热电电厂化学系统设计摘要社会经济的快速发展带动了我国工业的现代化发展,电厂尤为重要,其中如果电厂的水出现不达标的情况,就会导致出现锅炉结垢和积盐,故须对化学补给水进行处理。故这次毕设为化学补给水系统初步设计,通过设计补给水的处理流程,选择处理设备及规格使进水满足进入锅炉的要求。并完成设计说明书,绘制图纸。关键词:电厂;锅炉补给水系统;化学补给水处理abstractTherapiddevelopmentofthesocialeconomyhasdriventhemodernizationofChina'sindustry.Powerplantsareparticularlyimportant.Ifthewaterinthepowerplantfailstomeetthestandard,itwillleadtoboilerfoulingandsaltaccumulation.Therefore,chemicalrechargewatermustbetreated.Therefore,thistimeitwassetasthepreliminarydesignofthechemicalfeedwatersystem.Bydesigningthetreatmentprocessofthemake-upwater,thetreatmentequipmentandspecificationswereselectedtomeettherequirementsforenteringtheboiler.Andcompletethedesignspecificationanddrawthedrawings.Keywords:Powerplant:;Boilerfeedwatersystem:;Chemicalrechargewatertreatment
目录TOC\o"1-3"\h\z第一章概述 11.1设计依据 11.1.1指导教师发放的任务书 11.1.2大唐清苑热电电厂化学水处理系统设计初步设计文件。 11.1.3大唐清苑热电电厂化学水处理系统设计初步设计审查意见 11.1.4《火力发电厂设计技术规程》(DL5000-2000); 11.1.5《火力发电厂化学设计技术规程》(DL/T5068-2006); 11.1.6《压临界火力发电机组水汽质量标准》(DL/T912-2005); 11.1.7《火力发电机组及蒸汽动力设备水汽质量》(GB/T12145-1999); 11.1.8相关的国家法令、法规和规程规范。 11.2工程概况 11.3设计基础资料 21.3.1水源与水质 21.3.2水汽质量标准 31.4设计范围 41.4.1锅炉补给水处理系统; 41.4.2除盐水管道厂区部分。 4第二章锅炉补给水处理 52.1锅炉补给水处理系统出力及出水质量 52.1.1锅炉补给水处理系统出力 52.1.2锅炉补给水处理系统的出水质量 52.2锅炉补给水处理系统流程的确定 52.2.1系统流程 6第三章主要设备参数及系统控制 73.1锅炉补给水处理系统设备运行技术数据 73.1.1石英砂过滤器: 73.1.2活性炭过滤器: 73.1.3超滤装置: 73.1.4反渗透单元: 73.1.5逆流再生阳离子交换器 93.1.6逆流再生阴离子交换器 93.1.7混合离子交换器 93.2锅炉补给水处理设备的失效监督及控制方式 103.2.1石英砂过滤器 103.2.2活性炭过滤器 103.2.3反渗透装置 103.2.4阳离子交换器 103.2.5阴离子交换器 113.2.6混合离子交换器 113.3锅炉补给水处理系统的连接 113.4辅助系统 113.4.1化学药剂的运输及贮存 113.4.2排水的收集与处置 123.4.3压缩空气系统 123.5除盐水处理系统的控制功能及要求 12第四章化学水处理室设备布置 134.1锅炉补给水处理厂房 134.2锅炉补给水处理室外设备布置 13-第一章概述1.1设计依据1.1.1指导教师发放的任务书1.1.2大唐清苑热电电厂化学水处理系统设计初步设计文件。1.1.3大唐清苑热电电厂化学水处理系统设计初步设计审查意见1.1.4《火力发电厂设计技术规程》(DL5000-2000);1.1.5《火力发电厂化学设计技术规程》(DL/T5068-2006);1.1.6《压临界火力发电机组水汽质量标准》(DL/T912-2005);1.1.7《火力发电机组及蒸汽动力设备水汽质量》(GB/T12145-1999);1.1.8相关的国家法令、法规和规程规范。1.2工程概况大唐清苑热电电厂已建安装2×300MW亚临界国产燃煤抽凝式供热机组,锅炉额定蒸发量为1024t/h,并预留扩建场地。设计一套满足全厂所有发电机组需要的锅炉补给水处理系统。锅炉过热器出口蒸汽压力为17.5MPa,再热器出口蒸汽压力为3.505MPa,出口温度540℃,汽轮机主蒸汽压力16.7MPa,发电机额定功率300MW,冷却方式水氢。1.3设计基础资料1.3.1水源与水质大唐清苑热电电厂位于河北保定市,本期锅炉补给水处理系统采用保定市银定庄污水处理厂的出水为主水源,即中水为主水源,备用水源采用城市地地表水,有机物污染物含量大,水质复杂。水源的水质资料见表1“大唐清苑热电电厂水质全分析报告汇总表”,及表2“大唐清苑热电电厂备用水源水质全分析报告汇总表”。表1-1大唐清苑热电电厂水质全分析报告汇总检测离子结果(mg/L)结果(mmol/L)检测离子结果(mg/L)结果(mmol/L)阳离子K+22.00.56阴离子Cl-122.03.44Na+100.04.351/2SO42-78.01.621/2Ca2+79.43.96HCO3-419.86.881/2Mg2+35.02.881/2CO32-0.00.00NH4+28.01.54NO2-33.60.73——NO3-6.80.11F-0.50.03合计264.413.29合计660.712.81分析项目含量分析项目含量分析项目含量全硬度342.3永久硬度0.0活性硅22.0负硬度2.0暂时硬度342.3游离CO217.6总酸度20.0总碱度344.3CODMn25.0离子分析误差1.84%pH7.3——--表示检测不出或计算值极低备注/备用水源为保定市城市地表水,水质分析报告见表表1-2大唐清苑热电电厂备用水源水质全分析报告汇总样品名称:城市地表水水温:25℃外状:无色透明采样日期:2008.6.16报告日期:2008.6.25序号分析项目单位结果备注1PH7.322悬浮物mg/L03溶解固形物mg/L320.54CODmnmg/L0.6285二氧化硅(SiO2)mg/L7.986硅酸根mg/L8.017钠mg/L19.38氯根mg/L22.09硝酸根mg/L8.0310亚硝酸根mg/L011硫酸根mg/L52.0512磷酸根mg/L0.0513含氨量mg/L014重碳酸根mmol/L3.315碳酸根mmol/L016氢氧根mmol/L017酚酞碱度mmol/L018甲基橙碱度mmol/L3.319钙1/2〔Ca2+〕mmol/L2.3920镁1/2〔Mg2+〕mmol/L1.7721全硬度1/2〔Ca2++Mg2+〕mmol/L4.1622暂时硬度mmol/L3.323永久硬度mmol/L0.861.3.2水汽质量标准水汽质量标准按中华人民共和国电力行业标准2×300MW机组水汽质量标准按:《火力发电机组及蒸汽动力设备水汽质量》(GB/T12145-1999)执行。补给水质量以保证给水质量为标准,补给水质量可参照下表进行控制。表1-3补给水质量标准项目电导率(25℃)µS/cm二氧化硅µg/LTOCµg/L标准值≤0.20≤20≤200期望值≤0.15≤101.4设计范围1.4.1锅炉补给水处理系统;1.4.2除盐水管道厂区部分。第二章锅炉补给水处理2.1锅炉补给水处理系统出力及出水质量2.1.1锅炉补给水处理系统出力锅炉补给水处理系统设备的出力根据大唐清苑热电电厂现有和在规划的机组正常水汽损失,闭式热网损失20t/h,锅炉排污损失,以及启动或事故而增加的耗水量等因素综合考虑见下表:表2-1锅炉补给水处理正常补给水量和系统出力数据汇总表序号名称数量1机组的锅炉正常补给水量15.375t/h2闭式热网损失20t/h3锅炉排污损失10.25t/h4锅炉排污损失20t/h5因机组启动或事故而要增加的水处理设备出力61.5t/h6锅炉补给水处理系统设备出力正常45.625t/h最大107.125t/h7向给水系统正常补充的补充水量25.625t/h8正常情况下锅炉给水系统补水率2.48%2.1.2锅炉补给水处理系统的出水质量硬度:~0mol/L;电导率(25℃):≤0.20μS/cm期望值≤0.15μS/cm;二氧化硅:≤20μg/L期望值≤10μg/L;TOC:≤200μg/L。2.2锅炉补给水处理系统流程的确定本工程锅炉补给水处理系统根据中水水质复杂,以及有机物含量大,故锅炉补给水处理系统的方案采用预处理+一级复床除盐加混床。2.2.1系统流程中水(地表水备用)→石英砂过滤器→活性炭过滤器→自清洗过滤器→超滤→加酸,加亚硫酸钠,加阻垢剂→加热器→保安过滤器→RO→阳床→阴床→混床→除盐水箱→主厂房由于水中没有悬浮颗粒,故不设机械搅拌澄清池;石英砂过滤器去除水中可能存在的悬浮颗粒:活性炭过滤器去除水中的有机物,降低COD值,并通过还原作用去除余氯:超滤去除水中溶解固体:反渗透装置深度除盐,去除水中的杂质和胶体,一级复床加混床,使水达到进水要求。系统流程详见锅炉补给水处理系统流程图。第三章主要设备参数及系统控制3.1锅炉补给水处理系统设备运行技术数据3.1.1石英砂过滤器:4台,3用1备。直径DN2500mm,滤层高1200mm。设备运行流速取6m/h。根据细砂过滤器进水水质判断是否需要设置絮凝剂加药装置、加杀菌剂装置,加药点需设在进水母管。3.1.2活性炭过滤器:4台,3用1备。直径DN2500mm,滤层高1200mm。设备运行流速取5m/h。降低COD值,去除余氯。3.1.3超滤装置:超滤装置是通过两侧的压力差,经过超滤膜微孔有效去除水中的微粒,胶体,细菌和有机物。超滤装置的产水量为100.6m3/h,共用两套装置,每套超滤元件数为41件,选用美国海德能膜HYDRACAP60产生。(1)自清洗过滤器:利用滤网拦截水中的杂质,去除水中的悬浮物,颗粒物,降低浊度,以净化水质,保证超滤装置的正常进行。(2)化学清洗装置:超滤膜长时间运行可能会造成污染,比如结垢或有机物的积累,故需进行化学清理。(3)超滤反洗过滤器:由于进水中可能有胶体或者悬浮物,造成膜污染,以致超滤速率下降,为了恢复超滤速率,故须定期对超滤装置进行反洗,将膜表面的污染物冲洗掉。3.1.4反渗透单元:反渗透系统是锅炉补给水处理系统中主要的脱盐设备,其作用是去除水中的可溶性盐、溶硅、有机物等。本次设计设置2套,每套设计正常出力为71.86m3/h。反渗透单元包括:保安过滤器、高压泵、反渗透装置2台,化学清洗装置1套,加药系统、清洗系统及控制仪表。反渗透装置按一级二段设计。(1)保安过滤器设置保安过滤器的作用是截留进水带来的颗粒,以防止其进入反渗透系统划伤反渗透膜。(2)高压泵高压泵为反渗透装置提供足够大的进水压力,保证反渗透装置的正常运行。因为水温对反渗透装置的产水流量影响较大,即水温变化,在进水压力不变的情况下,其产水量也会增减。故本系统采用变频泵,改变进反渗透水的压力,以保证反渗透系统足够的动力,从而保证反渗透系统的产水能力。(3)反渗透本体装置本次设计设置2套反渗透装置,每套装置设计正常出力为71.86m3/h。反渗透膜采用的是美国海德能公司生产的CAP3聚酰胺复合膜,此型号反渗透膜的有效膜面积37.2m2,产水量按1.74m3/h(10℃)设计,单根膜最低脱盐率为99.7%。每套反渗透按一级二段设计,成7:3排列,每支压力容器内装6支膜,每套反渗透装置用60支膜。(4)反渗透加药系统a加阻垢剂系统加阻垢剂的作用是在反渗透装置进水管加入高效率的阻垢剂,以防止反渗透浓水中产生结垢或结盐。b加还原剂系统还原剂NaHSO3(亚硫酸氢钠)的作用是还原处理工艺中存在的余氯,以防止氧化物对膜产水量造成的减弱而导致反渗透膜脱盐率的下降。(5)反渗透清洗系统反渗透系统运行压力约1.40MPa,反渗透膜组件在长时间运行后会受到污染,如盐份结垢或有机物积累,造成膜组件性能下降,运行压力升高,故须用化学药品进行清洗,以恢复其除盐能力。一般情况下,每4~6个月清洗一次,每次清洗约1~2小时。本系统设置一套化学清洗装置,由2台化学清洗泵和1台化学清洗水箱组成。反渗透膜的维护和保养详见制造厂的维护和保养手册。(6)控制仪表为了监测和控制反渗透装置的工作情况,配置了电导率表、流量计、压力表、取样装置、流量开关和高压保护开关等监测和控制仪表。反渗透系统为全自动运行,产水设高压保护爆破膜。3.1.5逆流再生阳离子交换器(1)设备公称直径:DN2500mm(2)设备台数:2台(3)树脂类型:001×7型苯乙烯系强酸阳离子交换树脂,层高3000mm。(4)工作交换容量:800mol/m3(R);(5)设计正常出力:41.91m3/h(6)正常运行流速:9.77m/h(7)再生剂:采用31%的工业盐酸,再生液浓度取3%,流速为5m/h,酸耗取55g/mol,正常时,再生一次需要31%的工业盐酸1.28m3。3.1.6逆流再生阴离子交换器(1)设备公称直径:DN2500mm(2)设备台数:2台(3)树脂类型:201×7型苯乙烯系强碱阴离子交换树脂,层高2500mm。(4)工作交换容量:300mol/m3(R);(5)设计正常出力:47.91m3/h(6)正常运行流速:9.77m/h(7)再生剂:采用30%的工业碱,再生液浓度为1%,流速为5m/h,碱耗取65g/mol,正常时,再生一次需要30%的高纯度碱0.508m3。3.1.7混合离子交换器(1)设备公称直径:DN2500mm(2)设备台数:2台(3)树脂类型:001×7MB型苯乙烯系强酸阳离子交换树脂,层高500mm,201×7MB型苯乙烯系强碱阴离子交换树脂,层高1000mm。树脂再生采用体内再生方式。(4)设计正常出力:47.91m3/h(5)正常运行流速:26.4m/h(6)再生剂001×7MB型苯乙烯系强酸阳离子交换树脂采用31%的工业盐酸再生,再生液浓度为5%,流速为5m/h,酸耗取80kg/m3(R),正常时,再生一次需要31%的工业盐酸0.55m3。201×7MB强碱阴离子交换树脂采用30%的工业碱,再生液浓度为1%,流速为5m/h,碱耗取100kg/m3(R),正常时,再生一次需要30%的高纯度碱1.13m3。3.2锅炉补给水处理设备的失效监督及控制方式3.2.1石英砂过滤器石英砂过滤器当满足下列条件之一时,停止运行,进行反洗。a进出口压差达到设定值时;b周期制水量达到设定值时(经调试确定)。石英砂过滤器的投运和反洗,采用程序控制。3.2.2活性炭过滤器需24小时反洗一次。3.2.3反渗透装置反渗透装置投运和清洗,采用程序控制。3.2.4阳离子交换器阳离子交换器的失效监督指标有如下2个,当满足任一条件时,需停运再生。a当其出水Na>50g/L时;b当其周期制水量达到规定时(经调试确定)。阳离子交换器的投运和再生采用程序控制。3.2.5阴离子交换器阴离子交换器的失效监督指标有如下3个,当满足任一条件时,需停运再生。a当其出水电导率≥5S/cm时;b当其出水SiO2≥100g/L时;c当其周期制水量达到规定时(经调试确定)。阴离子交换器的投运和再生采用程序控制。3.2.6混合离子交换器混合离子交换器的失效监督指标有如下3个,当满足任一条件时,需停运再生。a当其出水电导率≥0.2S/cm时;b当其出水SiO2含量≥15g/L时;c当其周期制水量达到规定时(经调试确定)。混合离子交换器的投运和再生采用程序控制。3.3锅炉补给水处理系统的连接锅炉补给水处理系统主要制水设备均采用母管制并联连接。石英砂过滤器和活性炭过滤器采用母管制并联的连接。反渗透装置采用单元制连接。阳离子交换器、阴离子交换器和混合离子交换器则为母管制并联连接。石英砂过滤器和离子交换器均设备用,当1台设备失效时,自动解列该设备,投入备用设备,并对失效设备进行清洗或再生备用。3.4辅助系统3.4.1化学药剂的运输及贮存树脂的再生采用盐酸和氢氧化钠,杀菌剂采用次氯酸钠,还原剂采用固体亚硫酸钠。酸、碱采用汽车槽车运输,通过酸、碱输送泵到贮存罐贮存。树脂再生时,酸、碱从贮存罐自流到计量箱,经过喷射器将酸、碱液混合稀释分别送入离子交换器进行再生。另外,设置了酸、碱计量泵作为反渗透清洗装置配清洗液用,固体药剂采用搅拌溶液箱溶解后用计量泵送到加药点。3.4.2排水的收集与处置反渗透浓水做为化学清洗水箱的来水,一出水回收至化学清洗水箱,用于超滤装置和反渗透装置的化学清洗用水。设备的排水和再生废水排到废水中和池储存和处理合格后送至沉渣池回用。本工程设置了混凝土废水中和池1个,并设2台废水泵。中和池设有水力搅拌设施保证废水的充分混合与中和,达到pH值7-9时排放至沉渣池回用。3.4.3压缩空气系统压缩空气由主厂房仪用空压系统供给。用于供给锅炉补给水处理系统工艺及仪表用气。本工程设2台8m3的压缩空气贮存罐。其中1台用于石英砂过滤器和活性炭过滤器,另1台用于混床树脂混合。石英砂过滤器和活性碳过滤器的擦洗空气压力~0.098MPa;,混合离子交换器混脂用的压缩空气压力为0.1~0.15MPa;仪用气压力为0.6~0.8MPa,露点温度-40℃。3.5除盐水处理系统的控制功能及要求锅炉补给水处理系统的运行过程采用PLC自动化程序控制。系统的主要运行数据将送到控制系统,操作人员可在水处理控制室内通过CRT对系统的运行进行全过程的监督和控制。现场电磁阀箱保留进行人工按钮操作。反渗透装置的运行、加药等步骤都由PLC按程序自动进行。风机、泵和电动门等除了在控制室的遥控外,还设有就地控制开关。对于气动阀门能在电磁阀箱上进行控制,而且在手动时还能保持必要的联锁,但远方/就地切换在PLC内实现。水泵的控制受水箱液位高低的联锁,备用泵与运行泵互为联锁。凡是与腐蚀性介质接触的测量元件、阀门、逻辑开关、变送器、就地仪表等设备均满足相应介质的防腐要求。存放液体的箱、罐、池都有液位计和液位开关或远传连续式液位变送器。第四章化学水处理室设备布置4.1锅炉补给水处理厂房锅炉补给水处理厂房按规划容量一次建成,厂房设计为L型。水处理设备厂房占地为36×39m2,除盐厂房占地为10.8×27.8m2。除盐厂房包括了石英砂过滤器,活性炭过滤器,超滤装置,反渗透装置,自清洗过滤器,保安过滤器。辅助加药间占地为16.5×5.5m2,辅助加药间包括酸碱加药,阻垢剂,还原剂加药,罗茨风机,空气储罐。阳床,阴床,混床位于下方,占地22.4×4.6m2。酸碱储罐,中和池位于泵间右侧,占地12.5×11.5m2。泵间包括各种加药泵,清水泵,超滤水泵,反渗透水泵,反洗水泵,化学清洗水泵,高压泵等,占地7.64×22m2。化学办公楼位于厂房右侧,化验楼首层设有气象室、天平室、色谱分析室、女厕所、男厕所、更衣室、化验室仓库、就地化验间等;化验楼二层设有天平室、热计量间、煤分析室、仪器室、煤样分析间、油分析间、检修间等。4.2锅炉补给水处理室外设备布置中间水箱、除盐水箱、超滤水箱、反渗透水箱、化学清洗水箱、酸碱贮存罐、酸碱计量泵、中和池布置在水处理厂房室外。除盐水箱,超滤水箱,反渗透水箱,化学清洗水箱布置在厂房的上部,酸碱贮存罐,中和池位于箱体下方,厂房的右面。详见锅炉补给水处理平面布置图。附录:计算书1.原始资料1.1机组参数机组装机容量为2×300MW,锅炉为亚临界国产燃煤抽凝式汽包炉,额定蒸发量:1025t/h。1.2汽水损失厂内正常的水汽损失15.375t/h;考虑机组因启动或事故而要增加的水处理设备出力61.5t/h;闭式热网损失20t/h;锅炉排污损失10.25t/h。1.3水质分析数据检测离子结果(mg/L)结果(mmol/L)检测离子结果(mg/L)结果(mmol/L)阳离子K+22.00.56阴离子Cl-122.03.44Na+100.04.351/2SO42-78.01.621/2Ca2+79.43.96HCO3-419.86.881/2Mg2+35.02.881/2CO32-0.00.00NH4+28.01.54NO2-33.60.73——NO3-6.80.11F-0.50.03合计264.413.29合计660.712.81分析项目含量分析项目含量分析项目含量全硬度342.3永久硬度0.0活性硅22.0负硬度2.0暂时硬度342.3游离CO217.6总酸度20.0总碱度344.3CODMn25.0离子分析误差1.84%pH7.3——--表示检测不出或计算值极低备注/备用水源为保定市城市地表水,水质分析报告见下表水质全分析报告样品名称:城市地表水水温:25℃外状:无色透明采样日期:2008.6.16报告日期:2008.6.25序号分析项目单位结果备注1PH7.322悬浮物mg/L03溶解固形物mg/L320.54CODmnmg/L0.6285二氧化硅(SiO2)mg/L7.986硅酸根mg/L8.017钠mg/L19.38氯根mg/L22.09硝酸根mg/L8.0310亚硝酸根mg/L011硫酸根mg/L52.0512磷酸根mg/L0.0513含氨量mg/L014重碳酸根mmol/L3.315碳酸根mmol/L016氢氧根mmol/L017酚酞碱度mmol/L018甲基橙碱度mmol/L3.319钙1/2〔Ca2+〕mmol/L2.3920镁1/2〔Mg2+〕mmol/L1.7721全硬度1/2〔Ca2++Mg2+〕mmol/L4.1622暂时硬度mmol/L3.323永久硬度mmol/L0.862.水质分析资料的校核水质资料是选择化学水处理方案和工艺系统流程、进行水处理设备设计以及确定化学药品消耗量的重要资料,所以水质资料的正确与否,直接关系到设计结果是否正确及合理。为了确保水质资料准确无误,所以须在开始设计之前,对水质资料进行必要的校核校验。校核.就是根据水质中各个分析项目之间的关系。验证其水质资料数据的可靠性。在经过校核后如发现误差比较大时,应该重新取样进行分析。校核一般包括以下几个方面。2.1阴阳离子含量的校核根据电离平衡原理,水中各种阴离子单位电荷的总和等于各种阳离子单位电荷的总和。即阳离子单位电荷总和为:Σk=c(k+)+c(Na+)+c(½Ca2+)+c(½Mg2+)+c(NH+)=13.29mmol/L阴离子单位电荷总和为:ΣA=c(CI-)+c(½SO42-)+c(½CO32-)+c(HCO3-)+c(NO2-)+c(NO3-)+c(F-)=12.81mmol/Lδ=|(∑A-∑K)/∑A+∑K)|×100%=|(12.81-13.29)/(12.81+13.29)|×100%=1.84%<2%δ=1.84%<2%所以阴阳离子含量的审查通过。2.2含盐量与溶解固体的校核由于水质中无溶解固体的含量,无法校核。2.3碳酸氢根浓度的校正水质指标中未给出酚酞碱度,无法校核。2.4pH的校核要求其误差为对于的水样,可按下式计算=7.59所以=|7.3-7.59|=0.29>0.2校正不符合要求。3.补给水水量的确定已知资料:机组形式和装机容量为2×300MW,锅炉为亚临界压力自然循环汽包炉,额定蒸发量:1025t/h;汽水损失:正常运行时汽水损失;考虑机组启动或事故而要增加的水处理设备出力;闭式热网损失;锅炉排污损失。设计对补给水水量的要求,除了要能满足正常补给水量外,还要在非正常情况下,也能提供足够的合格补给水量。非正常情况是指机组启动或是事故状况下对水量的增加需要。具体的说,设计的补给水水量应满足下列诸方面需要。3.1汽水损失(1)正常运行时汽水损失对于200MW以上的机组,为锅炉最大连续蒸发量的1.5%。D1=15.375t/h(2)考虑机组启动或事故而要增加的水处理设备出力D2=61.5t/h(3)对外用汽损失D3D3=0t/h(4)其他用汽损失D4这部分损失包括生产和非生产用汽D4=0t/h(5)闭式热网损失D5该数据包括启动等非正常情况的需要、但正常与非正常损失之和不得小于20t/h。D5=20t/h(6)化学处理水的其他供应量D6D6=0t/h(7)闭式辅机冷却系统损失D7D7=0t/h(8)锅炉排污损失DpDp=10.25t/h3.2补给水水量的计算化学补给水处理设备的正常供水量为Qn′=(D1+D3+D4+D5+D6+D7+Dp)=15.375+20+0++0+0+10.25=45.625t/h化学补给水处理设备的最大供水量为Qmax′=(D1+D2+D3+D4+D5+D6+D7+Dp)=15.375+20+61.5+0+0+0+0+10.25=107.125t/h向给水系统正常补充的补给水量为Qw=D1+D3+D4+Dp=25.625t/h正常情况下锅炉给水系统补水率%为aw=2.48%4.工艺计算及选型4.1膜法补给水处理系统出力的计算水处理设备设计出力﹙m3/h﹚:正常Qn=αQn′=1.05×45.625=47.91(m3/h)最大Qmax=αQmax′=1.05×68.44=71.86(m3/h)4.2体内再生混床处理的计算(1)总工作面积正常An=Qn/v=47.91/40=1.20m2最大Amax=Qmax/v=71.86/40=1.80m2(v取40m/h)(2)选择混床台数D取2500mm,A=πd2/4=3.14×2.52/4=4.91m2正常nnM2=An/A=1.20/4.91=0.24,故nnM2取1最大nmaxM2=Amax/A=1.80/4.91=0.37,故nmaxM2取2选2台混床。(3)校验实际运行流速正常vn=Qn/﹙A1·nM2﹚=47.91/(4.91×0.37)=26.4m/h最大vmax=Qmax/﹙A1·nM2﹚=71.86/(4.91×0.37)=39.6m/h(4)混床内树脂体积(m3/台)hRC=500mmhRA=1000mm阳树脂VRC=A1·hRC=4.91×0.5=2.45(m3)阴树脂VRA=A1·hRA=4.91×1.0=4.91(m3)(5)混床周期制水时间T=(VRC+VRA)×24000×nM2/Qn=(2.45+4.91)×24000×0.37÷47.91=1362.3h≈57d因为T值很大,故取45d(6)再生时用酸量100%酸[kg/(台·次)]:ma,p=VRC·g=2.45×75=183.75kg/(台·次)(g=75kg/m3)工业酸[kg/(台·次)]:ma,i=ma,p/ε=183.75/31%=592.74kg/(台·次)(ε=31%)再生用酸液[kg/(台·次)]:ma,r=ma,p/c=183.75/5%=3675kg/(台·次)(c=3%)稀释用水(m3):Va=(ma,r-ma,i)/1000=(3675-592.74)/1000=3.08m3进酸时间(min):ta=60ma,r/(1000A1·va·ρ)=60×3675/(1000×4.91×1×1.02)=44.06min(ρ=1.02g/cm3,va=1m/h)(7)再生时用碱量100%碱[Kg/(台·次)]:ms,p=VRA·g=4.9×70=343kg/(台·次)(g=70kg/m3树脂)工业碱[Kg/(台·次)]:ms,i=ms,p/ε=343/30%=1143.33kg/(台·次)(ε=30%)再生用碱液[Kg/(台·次)]:ms,r=ms,p/c=343/4%=8575kg/(台·次)(c=4%)稀释用水(m3):Vs=(ms,r-ms,i)/1000=(8575-1143.33)/1000=7.43m3进碱时间(min):ts=60ms,r/(1000A1·vs·ρ)=60×8575/(1000×4.91×2×1.04)=51.91min(vs=2m/h,ρ=1.04g/cm3)(8)再生时自用水量[m3/(台·次)]反洗用水Vb=v·A1·t/60=10×4.91×15/60=12.27m3/(台·次)(v=10m/h,t=15min)置换用水Vd=(VRC+VRA)·αd=(4.9+2.45)×2=14.7m3/(台·次)(αd=2m3/m3)正洗用水Vf=VRC·αc+VRA·αa=2.45×6+4.9×12=73.5m3/(台·次)(αc=6m3/m3,αa=12m3/m3)集中供应自用水V2=Vs+Va+Vd+Vb=7.43+3.08+12.27+14.7=37.48m3/(台·次)总自用水Vt=Vf+Vs+Va+Vd+Vb=Vf+V2=73.5+37.48=110.98m3/(台·次)(9)再生用压缩空气量[m3/(台·次)]VaiM2=q·A1·t=3×4.91×1=14.72m3/(台·次)(q取3m3/(m2·min),t取1min)(10)每天耗工业酸量﹙t)maM2=ma,i·nM2/﹙1000T﹚=592.74×1/﹙1000×45﹚=0.013t(11)每天耗工业碱量(t)msM2=ms,i·nM2/﹙1000T﹚=1143.33×1/﹙1000×45﹚=0.025t(12)年耗酸量(t)ma,aM2=maM2×7000/24=0.013×7000÷24=2.92t(13)年耗碱量(t)ms,aM2=msM2×7000/24=0.025×7000÷24=7.29t(均以年运行7000h计)(14)每小时自用水量(m3/h)由前级提供自用水:ViM2=Vf×nM2/T=73.5×1÷45÷24=0.0336m3/h集中供应自用水:V2M2=V2×nM2/T=37.48×1÷45÷24=0.035m3/h总自用水:VtM2=Vt×nM2/T=110.98×1÷45÷24=0.10m3/h4.3强碱阴交换器的计算(1)阴床设计出力﹙m3/h﹚正常Qn=αQn′=1.05×45.625=47.91(m3/h)最大Qmax=αQmax′=1.05×68.44=71.86(m3/h)(2)总工作面积正常An=Qn/v=47.91/20=2.40m2最大Amax=Qmax/v=71.86/20=3.60m2(v取20m/h)(3)选择阴离子交换器台数D取2500mm,A=πd2/4=3.14×2.52/4=4.91m2正常nnM2=An/A=2.40/4.91=0.49,故nnM2取1最大nmaxM2=Amax/A=3.60/4.91=0.73,故nmaxM2取2选2台阳床。(4)校验实际运行流速正常vn=Qn/﹙A1·nM2﹚=47.91/(4.91×0.37)=26.4m/h最大vmax=Qmax/﹙A1·nM2﹚=71.86/(4.91×0.37)=39.6m/h(5)阴床内树脂体积(m3/台)hRA=3000mm阴树脂VRA=A1·hRA=4.91×3.0=14.72(m3/台)(6)正常出力时阴床周期制水时间T=VRA×250×nM2/Qn=14.72×250×1÷47.91÷1.41=54.48h(7)再生时用碱量100%碱[Kg/(台·次)]:ms,p=VRA·gs·EA/1000=14.72×250×60÷1000=220.8Kg/(台·次)(g=60kg/m3树脂)工业碱[Kg/(台·次)]:ms,i=ms,p/ε=220.8/30%=736Kg/(台·次)(ε=30%)再生用碱液[Kg/(台·次)]:ms,r=ms,p/c=220.8/1%=22080Kg/(台·次)(c=1%)稀释用水(m3):Vs=(ms,r-ms,i)/1000=(22080-736)/1000=21.34m3进碱时间(min):ts=60ms,r/(1000A1·vs·ρ)=60×22080/(1000×4.91×5×1.04)=51.93min(vs=5m/h,ρ=1.04g/cm3)(8)再生时自用水量[m3/(台·次)]反洗用水Vb=v·A1·t/60=5×4.91×15/60=6.13m3/(台·次)(v=5m/h,t=15min)正洗用水Vf=VRA·αd=14.72×1=14.72m3/(台·次)(αd=1m3/m3)集中供应自用水V2=Vs+Vb=21.34+6.13=27.47m3/(台·次)总自用水Vt=Vf+Vs+Vb=27.47+14.72=39.19m3/(台·次)(9)每天耗工业碱量(t)msA=ms,i·nA·R/1000=1143.33×1×0.44/1000=0.32t(10)年耗碱量(t)ms,aA=msA×7000/24=0.32×7000÷24=94.45t(均以年运行7000h计)(11)每小时自用水量(m3/h)由前级提供自用水:ViA=Vf×nA×R/24=14.72×0.44×1÷24=0.27m3/h集中供应自用水:V2A=V2×R×nA/24=27.47×0.44×1÷24=0.50m3/h总自用水:VtA=Vt×R×nA/T=39.19×0.44×1÷24=0.72m3/h4.4强酸阳交换器的计算(1)阳床设计出力﹙m3/h﹚正常Qn=αQn′=1.05×45.625=47.91(m3/h)最大Qmax=αQmax′=1.05×68.44=71.86(m3/h)(2)总工作面积正常An=Qn/v=47.91/20=2.40m2最大Amax=Qmax/v=71.86/20=3.60m2(v取20m/h)(3)选择阳离子交换器台数D取2500mm,A=πd2/4=3.14×2.52/4=4.91m2正常nnM2=An/A=2.40/4.91=0.49,故nnM2取1最大nmaxM2=Amax/A=3.60/4.91=0.73,故nmaxM2取2选2台阳床。(4)校验实际运行流速正常vn=Qn/﹙A1·nM2﹚=47.91/(4.91×1)=9.77m/h最大vmax=Qmax/﹙A1·nM2﹚=71.86/(4.91×1)=14.65m/h(5)阳床内树脂体积(m3/台)hRA=3000mm阴树脂VRA=A1·hRA=4.91×3.0=14.72(m3/台)(6)正常出力时阳床周期制水时间T=VRC×800×nc/Qn=14.72×800×1÷47.91÷0.66=372h(7)再生时用酸量100%酸[Kg/(台·次)]:ma,p=VRC·gc·Ec/1000=14.72×800×50÷1000=588.8Kg/(台·次)(g=50kg/m3树脂)工业酸[Kg/(台·次)]:ma,i=ma,p/ε=588.8/31%=1899.35Kg/(台·次)(ε=31%)再生用酸液[Kg/(台·次)]:ma,r=ma,p/c=588.8/3%=19626.7Kg/(台·次)(c=3%)稀释用水(m3):Va=(ma,r-ma,i)/1000=(19626.7-1899.35)/1000=17.73m3进酸时间(min):ta=60ma,r/(1000A1·va·ρ)=60×19626.7/(1000×4.91×5×1.02)=58.83min(vs=5m/h,ρ=1.02g/cm3)(8)再生时自用水量[m3/(台·次)]反洗用水Vb=v·A1·t/60=5×4.91×15/60=6.13m3/(台·次)(v=5m/h,t=15min)正洗用水Vf=VRA·αd=14.72×1=14.72m3/(台·次)(αd=1m3/m3)集中供应自用水V2=Va+Vb=17.73+6.13=23.86m3/(台·次)总自用水Vt=Vf+Va+Vb=23.86+14.72=38.58m3/(台·次)(9)每天耗工业酸量(t)msA=ma,i·nC·R/1000=1899.35×1×0.065/1000=0.12t(10)年耗酸量(t)Ma,aA=maA×7000/24=0.12×7000÷24=35t(均以年运行7000h计)(11)每小时自用水量(m3/h)由前级提供自用水:ViA=Vf×nC×R/24=14.72×0.065×1÷24=0.040m3/h集中供应自用水:V2C=V2×R×nC/24=23.86×0.065×1÷24=0.065m3/h总自用水:VtC=Vt×R×nC/T=38.58×0.065×1÷24=0.10m3/h4.5反渗透的计算说明选用海德能公司的CPA3膜,一级两段式,水回收率y=0.5+(1-0.50)×0.5=75%(1)反渗透处理水量的计算:一级反渗透产水水量QROⅠ=Qmax=71.86(m3/h)一级反渗透进水水量QFROⅠ=QROP=QROⅠ/y=71.86/75%=95.81(m3/h)(2)一级反渗透膜元件、膜组件及排列方式:①所需膜元件数nel=QROⅠ/(α·Q′el﹚=71.86/﹙0.75×1.74﹚≈56个;(其中,α取75%,Q′el=1.74m3/h)②膜组件个数np=nel/N=56/6=9.3个,取10个其中选用6m长的膜组件,膜元件为40in,当水回收率为75%时,第一段压力容器数量系数r1为0.667,第二段压力容器数量系数r2为0.333③每段压力容器(膜组件)数为第一段:nP,1=r1×np=0.667×第一段:nP,2=r2×np=0.333×④实际使用的膜组件数为npROⅠ=﹙np,1+np,2﹚=10个实际使用的膜元件数为nelROⅠ=N·npROⅠ=6×10=60个④平均每个膜元件的产水量Qel=QROⅠ/nelROI=71.86/60=1.20(m3/h)一级反渗透第一段每支膜组件进水量Qin,el=QFROI/np,l=QROI/ynp,l=71.86/(0.75×7)=13.69(m3/h)⑤分为2组,每组30个膜元件,且一台停运时出水仍能达到正常产水要求。(3)保安过滤器:选择普睿泽DSF系列大流量保安过滤器的PR2-DSF740,每组反渗透选用一台保安过滤器,共需2台保安过滤器。设计流量:Q=150m3/h设计压力:1.0MPa滤芯材质:PP折叠过滤精度:5μm设备尺寸:Φ600×2100×4mm连接口径:DN200mm(4)高压泵计算:高压泵(多级泵)名称:ZD型卧式自平衡多级泵型号:ZD100J-46×9100-设计流量,m3/hJ-机械密封46-设计泵的单级扬程9-泵的级数生产厂家:长沙三昌泵业有限公司(5)杀菌剂的计算:杀菌剂:次氯酸钠生产厂家:济南润福德化工有限公司每小时耗量为mcl=QRO,PgCl×10÷100÷1000=98.21×10÷100÷1000=0.0098Kg/h每天耗量为mclRO,P=24×mcl÷1000=24×0.0098÷1000=2.35×10-4(t)每年耗量为mcl,aRO,P=7000mcl/1000=7000×0.0098÷1000=0.069(t)每小时投加次氯酸钠药液量VclRO,P=mcl/1000ρ=0.0098÷1000÷1.1=8.91×10-6m3上式中gCl次氯酸钠剂量,通常为1至几,取2,mgCl2/Lρ次氯酸钠药液密度,g/cm3(6)还原剂的计算:还原剂:NaHSO3生产厂家:廊坊天科生物科技有限公司每小时投加量为mr=QRO,Pgr÷ε÷1000=98.21×4÷0.75÷1000=0.049(Kg/h)每天耗量为mrRO,P=24×mcl÷1000=24×0.049÷1000=0.0012(t)每年耗量为mr,aRO,P=7000mr/1000=7000×0.049÷1000=0.343(t)每小时投加次氯酸钠药液量VrRO,P=mr/1000c=0.049÷1000÷0.031=0.0016(m3)上式中gr还原剂剂量,mg/Lε药品纯度,%(7)阻垢剂的计算:阻垢剂:六偏磷酸钠生产厂家:潍坊兴泰化工有限公司每小时投加药液量为Vin=QRO,Pgin÷ρ÷1000=98.21×2÷1.15÷1000=0.1708(L)每天加入的八倍浓缩液量为minRO,P=24×QROIgin÷8÷1000=24×95.81×2÷8÷1000=0.57(Kg)每年阻垢剂剂量为min,aRO,P=7000minRO,P÷24÷1000=7000×0.57÷24÷1000=0.17(t)上式中ρ阻垢剂八倍稀释液的密度,g/cm34.6超滤的计算说明(1)超滤装置的计算厂家:海德能型号:HYDRACap60膜元件超滤器的产水量(即进水量)QUFRO,p=1.05QRO,p=1.05×95.86=100.6(m3/h)②所需超滤元件数nUF=(1.05QFROI/α·J·M)×1000=[1.05×100.6/(1×46.5×59)]×1000=42个其中选用,α取1.0,M=46.5㎡,J=59L/﹙㎡·h﹚;共分为2组,每组有21个超滤元件。4.7石英砂过滤器的计算说明选用山东斯博康环保公司生产的过滤设备设计出力:QRO,p=QFROI+b,又b=5%QRO,P,得出QRO,P=98.21(m3/h)设备台数:4台n=4QRO,P/πd2v=4×98.21÷3.14÷2.52×6≈4台(v取6m/h,d取2500mm)n取4台滤层高度:1200mm4.8活性炭过滤器的计算说明选用山东斯博康环保公司生产的过滤设备设计出力:QRO,p=QFROI+b,又b=5%QRO,P,得出QRO,P=98.21(m3/h)设备台数:4台n=4QRO,P/πd2v=4×98.21÷3.14÷2.52×5≈4台(v取5m/h,d取2500mm)n取4台反洗周期:24h5辅助系统及箱体管道水泵的选型说明5.1水箱的计算说明(1)除盐水箱直流炉凝汽式电厂,除盐水箱的容积是最大锅炉连续蒸发量的3倍V=3×1025=3075m3故选择4台800m3的圆形水箱,φ10200mm,顶型:球面顶加浮顶减少二氧化碳的进入(2)反渗透水箱容积为1-2h的产水量V=2×QROⅠ=2×71.86=143.7m3故选择1台150m3的圆形水箱,φ6560mm,顶型:球面顶(3)超滤水箱V=2×QUFRO,p=2×100.6=201.2m3故选择1台250m3的圆形水箱,φ7320mm,顶型:球面顶(4)酸碱箱的选择(汽车运输30天)加酸:每天:0.013+0.12=0.133tV =0.133/1.15=0.12m3储存罐:0.12×30=3.6m3故用2台4m3箱,并配有1台型号QBY1Z-25,规格Q=16.8m3/h,H=50m的卸酸泵,其生产厂家为上海帕特泵业。酸计量箱:阳床再生一台1m3,混床再生一台1m3厂家:无锡宝成防腐设备厂加碱:每天:0.025+0.32=0.345tV =0.345/1.41=0.24m3储存罐:0.24×30=7.2m3故用3台4m3箱,并配有1台型号QBY1Z-25,规格Q=16.8m3/h,H=50m的卸酸泵,其生产厂家为上海帕特泵业。碱计量箱:阴床再生一台1m3,混床再生一台1m3厂家:无锡宝成防腐设备厂(5)酸雾吸收器选择规格效率达95%,Q=1m3/h的酸雾吸收器,数量为1台,选择型号BJS-4。(6)中和池混合离子交换器的再生废液需要中和池系统来统一处理,根据全厂的酸碱废液、置换用水等的量,确定建造一座容积为200m3的中和池。中和池防腐方法:防腐涂层,衬玻璃钢(防腐涂层厚度2-3mm;玻璃钢4-6层)。5.2管道的计算说明依据公式:d≥泵前v:1m/s泵后v:2.5m/s(1)过滤前的清水泵:泵前:计算得d=194mm故选DN200mm,壁厚3mm的Q235-φ200×3的普通钢管泵后:计算得d=120mm故选DN120mm,壁厚3mm的Q235-φ120×3的普通钢管(2)超滤水泵:泵前:计算得d=188.7mm故选DN200mm,壁厚3mm的Q235-φ200×3的普通钢管泵后:计算得d=119.3mm故选DN125mm,壁厚3mm的Q235-φ125×3的普通钢管(3)反渗透水泵:泵前:计算得d=159.5mm故选DN180mm,壁厚3mm的Q304-φ180×3的不锈钢管泵后:计算得d=100.9mm故选DN120mm,壁厚5mm的Q304-φ120×3的不锈钢管(4)除盐水泵:泵前:计算得d=159.5mm故选DN180mm,壁厚3mm的Q304-φ180×3的不锈钢管泵后:计算得d=100.9mm故选DN120mm,壁厚5mm的Q304-φ120×3的不锈钢管5.3水泵的计算说明(1)清水泵出口流量107.1m3/h泵的规格:Q=120m3/h,扬程H=74.5m,电机功率5.5kW型号为IS100-65-250,离心泵设3台清水泵(2用1备)厂家:河北高泰泵业(2)中间水泵泵的规格:Q=100m3/h,扬程H=20m,电机功率5.5kW型号为EG80/125-11/2,离心泵设2台中间水泵厂家:河北高泰泵业(3)超滤水泵出口流量100.6m3/h泵的规格:Q=120m3/h,扬程H=74.5m,电机功率5.5kW型号为IS100-65-250,离心泵设3台超滤水泵(2用1备)厂家:河北高泰泵业(4)反渗透高压泵泵的规格:Q=100m3/h,扬程H=414m,型号为ZD100J-46×9,多级离心泵设2台反渗透水泵厂家:河北高泰泵业(5)反渗透水泵出口流量71.86m3/h泵的规格:Q=86.6m3/h,扬程H=60m,电机功率5.5kW型号为IS100-65-250B,离心泵设3台反渗透水泵(2用1备)厂家:河北高泰泵业(6)除盐水泵考虑进入锅炉,压力较大泵的规格:Q=100m3/h,扬程H=125m,电机功率5.5kW型号为IS100-65-315,离心泵设3台除盐水泵(2用1备)厂家:河北高泰泵业(7)其他用泵部分=1\*GB3①超滤反洗水泵泵的规格:Q=120m3/h,扬程H=30.5m,电机功率5.5kW型号为IS125-100-315,离心泵数量:2台(1用1备)厂家:河北高泰泵业反渗透反洗水泵泵的规格:Q=120m3/h,扬程H=30.5m,电机功率5.5kW型号为IS125-100-315,离心泵数量:2台(1用1备)厂家:河北高泰泵业③反渗透清洗水泵泵的规格:Q=60m3/h,扬程H=50m,电机功率5.5kW型号为EG80/100-11/2,离心泵数量:1台厂家:河北高泰泵业④中和池水泵泵的规格:Q=150m3/h,扬程H=45m,电机功率5.5kW型号为EG100/200-11/2,离心泵数量:2台厂家:河北高泰泵业=5\*GB3⑤还原剂计量泵泵的规格:Q=7.5L/min,扬程H=23m型号:IH50-32-125数量:2台(1用1备)厂家:河北高泰泵业=6\*GB3⑥阻垢剂计量泵泵的规格:Q=7.5L/min,扬程H=23m型号:IH50-32-125数量:2台(1用1备)厂家:河北高泰泵业=9、10\*GB3=7\*GB3⑦酸计量泵泵的规格:Q=7.5L/min,扬程H=23m型号:IH50-32-125数量:2台(1用1备)厂家:河北高泰泵业=9、10\*GB3=8\*GB3⑧碱计量泵泵的规格:Q=7.5L/min,扬程H=23m型号:IH50-32-125数量:2台(1用1备)厂家:河北高泰泵业=9、10\*GB3=9\*GB3⑨NaClO计量泵泵的规格:Q=7.5L/min,扬程H=23m型号:IH50-32-125数量:2台(1用1备)厂家:河北高泰泵业=9、10\*GB35.4阀门的计算说明阀门的选型要根据所连接管道的外径来确定其口径大小,还要考虑操作性跟流经的流体的性质,来选择合适的阀门种类。经设计选用气动止回阀、安全阀、截止阀、气动耐腐蚀蝶阀、气动衬胶隔膜阀等阀门。清水泵配套阀门 进口截止阀DN200PN1.0 5 20#碳钢出口止回阀 DN125PN1.0 5 20#碳钢出口截止阀DN125PN1.0 5 20#碳钢石英砂过滤器配套阀门 进水截止阀DN250PN1.0 4 20#碳钢出水截止阀DN200PN1.0 4 20#碳钢反洗进水截止阀 DN200PN1.0 4 20#碳钢反洗出水截止阀 DN200PN1.0 4 20#碳钢正洗出水截止阀 DN200PN1.0 4 20#碳钢进气进口截止阀 DN200PN1.0 4 20#碳钢排空截止阀DN50PN1.0 4 20#碳钢活性炭过滤器配套阀门 进水截止阀DN250PN1.0 4 20#碳钢出水截止阀DN200PN1.0 4 20#碳钢反洗进水截止阀 DN200PN1.0 4 20#碳钢反洗出水截止阀 DN200PN1.0 4 20#碳钢正洗出水截止阀 DN200PN1.0 4 20#碳钢进气进口截止阀DN200PN1.0 4 20#碳钢排空气动截止阀 DN50PN1.0 4 20#碳钢超滤水泵配套阀门 进口截止阀 DN200PN1.0 3 20#碳钢出口止回阀 DN125PN1.0 3 20#碳钢出口截止阀DN125PN1.0 5 20#碳钢超滤装置配套阀门 自清洗过滤器进口截止阀DN250PN1.02 20#碳钢自清洗过滤器出口截止阀DN250PN1.0 2 20#碳钢进口气动耐腐蚀蝶阀 DN250PN1.0 2 20#碳钢出口气动耐腐蚀蝶阀 DN200PN1.0 2 20#碳钢浓水排污耐腐蚀蝶阀DN100PN1.04 20#碳钢超滤反洗截止阀 DN250PN1.0 2 20#碳钢超滤化学清洗进口截止阀DN250PN1.0 2 20#碳钢超滤化学清洗出口截止阀 DN250PN1.0 4 20#碳钢超滤水箱配套阀门 进水截止阀 DN200PN1.0 1 衬胶碳钢排污截止阀 DN100PN1.0 1 衬胶碳钢出水截止阀DN200PN1.0 1 衬胶碳钢超滤反洗过滤器排污截止阀DN200PN1.01 衬胶碳钢超滤反洗水泵配套阀门 进口截止阀 DN250PN1.0 2 P-铬镍系不锈钢出口止回阀 DN200PN1.0 2 P-铬镍系不锈钢出口截止阀DN200PN1.0 2 P-铬镍系不锈钢超滤产水泵配套阀门 进口截止阀 DN200PN1.0 2 P-铬镍系不锈钢出口止回阀 DN125PN1.0 2 P-铬镍系不锈钢出口截止阀DN125PN1.0 2 P-铬镍系不锈钢保安过滤器配套阀门 进水截止阀DN250PN1.0 2 衬胶碳钢排污截止阀DN100PN1.0 2 衬胶碳钢出水截止阀DN200PN1.0 2 衬胶碳钢排空截止阀DN50PN1.0 2 20#碳钢反渗透系统配套阀门 进口截止阀DN250PN2.6 2 衬胶碳钢出口截止阀DN150PN1.0 2 衬胶碳钢浓水排污截止阀 DN50PN1.0 4 P-铬镍系不锈钢浓水排污蝶阀DN50PN1.0 4 P-铬镍系不锈钢反渗透化学清洗截止阀DN200PN1.0 2 P-铬镍系不锈钢浓水回用排出截止阀 DN200PN1.0 6 P-铬镍系不锈钢反渗透清洗进水截止阀 DN200PN1.0 2 P-铬镍系不锈钢反渗透水箱配套阀门 出口截止阀DN200PN1.0 1 衬胶碳钢排污截止阀DN100PN1.0 1 衬胶碳钢进水截止阀DN200PN1.0 1 衬胶碳钢排空截止阀DN50PN1.0 1 衬胶碳钢反渗透水泵配套阀门 进口截止阀 DN150PN1.0 2 衬胶碳钢出口止回阀 DN100PN1.0 2 衬胶碳钢出口截止阀DN100PN1.0 2 衬胶碳钢反渗透反洗水泵配套阀门 进口截止阀DN150PN1.0 2 衬胶碳钢出口止回阀DN100PN1.0 2 衬胶碳钢出口截止阀DN100PN1.0 2 衬胶碳钢阳离子交换器配套阀门 进水气闭式衬胶隔膜阀DN150PN1.0 2 衬胶碳钢出水气闭式衬胶
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025广东云浮云城区“粤聚英才·粤见未来”招聘机关事业单位急需紧缺人才8人 粤港澳大湾区(广东)人才港专场笔试模拟试题及答案解析
- 读《三国演义》有感集锦
- 幼儿园、小学适用-“小手拉大手分类齐步走”垃圾分类实践活动方案
- 适应市场竞争的企业策略
- 逃离外企工作总结
- 部门管理会议
- 2024秋之圆装饰家装公司抖音推广营销方案
- 汽车线束技术要求-征求意见稿
- 人教河南 九年级 下册 语文 第一单元《 祖国啊我亲爱的祖国》习题课 课件
- 人教河南 九年级 下册 语文 第二单元《 溜索》习题课 课件
- 冻猪肉储备投标方案
- 临床科室综合目标管理考核标准
- 2023年广东省深圳市龙华区中考道德与法治二模试卷及答案解析
- 中国书画艺术品投资(山东联盟)知到章节答案智慧树2023年山东财经大学
- 高中学生社会实践活动100例
- 天津渔港防波堤施工组织设计
- 公司样品承认书
- YY/T 1870-2023液相色谱-质谱法测定试剂盒通用要求
- 博科ERP产品介绍
- 后张法预应力T梁预制施工方案
- 丙醇安全技术说明书MSDS
评论
0/150
提交评论