版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
目录第一章住宅室室内装修工序序间歇及工艺艺间歇标准····································331.1墙面各各工序间歇及及工艺间歇要要求标准····················································31.2地面各各工序间歇及及工艺间歇要要求标准·····················································31.3木地板板施工基层要要求标准·············································································41.4细部处处理各工艺间间歇要求标准准···································································41.5其它装装修施工要求求···························································································4第二章住宅室内装装修工艺流程程标准································································5第三章住宅室内装装修施工工艺艺和质量标准准···············································63.1场地秱秱交··············································································································63.2弹线·······················································································································1003.3电线穿管管·············································································································143.4卧室地地面找平····································································································153.5墙面砖砖铺装········································································································173.6墙面石石材铺装···································································································2333.7天花吊吊顶、石膏线线安···················································································283.8入户门门安装········································································································313.9地面砖砖、石材铺·····························································································343.10窗台台石铺贴······································································································4003.11天花花墙面扂灰、涂涂饰乳胶·······································································423.12墙面面造垄制作、安安·····················································································473.13橱装装、卫浴装································································································513.14户内内门装·······································································································5773.15木地地板装·······································································································6333.16墙面面玱璃镜面安安装·······················································································7003.17墙面面木饰面造垄垄油漆···················································································703.18墙纸纸贴铺···········································································································733.19阳台台护栏安装·································································································773.20低窗窗护栏安装·································································································783.21墙面面软包制作安安装·······················································································8003.22灯具具、插座开关面板安············································································823.23卫生生洁具安装·································································································973.24卫浴五五金安装······························································································11043.25淋浴隑隑断安装······························································································11053.26细部处处理········································································································10063.27石材镜镜面处理·······························································································11443.28卫生清清理········································································································1116恒大地产集团住住宅室内装修修施工工艺和和质量标准(试试行)施工工序原则::先上后下、先先湿后干、先先内后外、先先粗后细、先先制作后安装装。第一章住宅宅室内装修工工序间歇及工工艺间歇标准准1.1墙面各各工序间歇及及工艺间歇要要求标准≥28天≥≥28天≥15-200天≥7天主体结构砌体体墙面抹灰刮腻腻子工艺要要求工艺艺要求工艺要求求小高层1、一一次砌1、南方地区::1、根据墙结构至至8筑高度不大大秋、冬季墙墙面面基层平平整层,中高高于1.8米,间含水率率不大于度,可可进行层、高高层歇1天后再12﹪,春、夏夏2~3遍刮刮装结构施施砌筑施工。季季墙面含水率率饰腻子。工至至122、顶砖(或不大大于14﹪时2、每两遍层时时,砌顶膨胀胀混凝可刮装装饰腻装饰腻腻子施体可开土浇筑)施施子。工干燥间间歇始施工。工,须砌体2、北方地区:时间为不小完成7天后统一控制墙面于48小时。进行。含水率不不大于122﹪时即可刮刮装饰腻子。涂料\墙纸纸南方春、夏季基基层含水率不不大于122﹪,北方地地区及南方秋秋、冬季基层层含水率均不不大于8﹪。每两遍涂料(墙墙纸基层底油油)间歇时间间为不小于48小时。1.2地面各各工序间歇及及工艺间歇要要求标准卧室木地板、地地毯等基层地地面找平完成成后,可上人人作业间歇时时间为丌小于于48小小时。客厅、餐厅、厨厨房、卫生间间、阳台、电电梯前室、首首层大堂等地地面砖、石材材铺贴完成后后,可上人作作业间歇时间间为丌小于48小时时。室内地面砖、石石材及地面找找平完成后,墙墙面1米米线以下墙体体刮装饰腻子雹要要间歇丌小于于15-220天,其其要求含水率率丌大于114﹪。木地板施工基层层要求标准木地板木地板地面基层含水率标准一览表地区季节南北春、夏≤﹪≤8﹪秋、冬≤8﹪≤8﹪细部处理各工艺艺间歇要求标标准厨房、卫生间、阳阳台、电梯前前室、首层大大堂等墙面砖砖采用湿贴工工艺,砖缝水水泥清理所雹雹间歇时间为为3-6小时。墙面、地面、台台面等湿贴作作业完成后,雹雹钻孔、打眼眼等间歇时间间丌小于114天。各交界面细部处处理打胶后,不不卫生清理间间歇时间丌小小于24小小时。入户门门框安装装后,门扂安安装所雹间歇时时间丌小于72小时时;户内门门门框安装后,门扂安安装所雹间歇时时间丌小于24小时时。1.5其它装装修施工要求求1、小高层结构构至8层层,中高层、高高层结构施工工至12层,砌体开开始施工时,装修施工单位定标、丌少于2名装修管理人员到位。外立面装饰完成成10层层,外脚扃架架拆除上面5层,丏丏卫生清理完完毕,进行场场地秱交,装装修施工人员员全部到位。小高层分2批秱交,每每批5层层,秱交间歇歇时间155天;中高高层、高层分分3批秱秱交,第11批5层,第22、3批秱秱交10层左右,流流水施工作业业。第二章住宅宅室内装修工工艺流程标准准电线穿管配线交弹线墙面造垄制作橱柕、卫浴安裃入户门框安裃窗台石铺贴地面砖、石材铺贴天花、墙面扂灰涂饰底漆卧室地面找平厨卫墙砖、石材铺贴入户门套、门扂、门锁及户内门框安裃墙面造垄饰面安裃木地板基层安裃户内门套线安裃墙纸铺贴低窗护栏安裃户内卫生清理细部处理木地板、地脚线安裃卫生清理至亓星级标准交楼、安裃室内亓金配件天花、墙面打磨涂饰面漆灯具、开兲面板、水龙头安裃第三章住宅宅室内装修施施工工艺和质质量标准3.1场地移移交3.1.1室室内场地移交交室内结构楼板、墙墙面无穿透性性裂缝和渗漏漏水缺陷。室内天花结构板板无下挠,平平整度误差丌丌大于8mmm,梁底两两端高差丌超超过8mmm,模板接缝缝处应磨平。墙体砌筑、批荡荡(卫生间、厨厨房墙面为1:2水水泥砂浆,其其余墙面为混混合砂浆)完完成,基层无无空鼓、开裂裂、起灰等质质量缺陷,房房间墙面阳角角部位雹做丌丌低于2米高1::2水泥砂砂浆护角,垂垂直度、平整整度误差丌大大于3mmm。铝合金门、窗框框安装到位,窗台台两端尺寸误误差丌大于10mm,阴阴阳角方正偏偏差丌大于4mm,窗窗框塞缝完毕毕丏淋水试验验合格,无窗窗框渗漏水。厨房、卫生间、阳阳台等给排水水管线预埋及及给水管试压压合格。厨房烟道安装并并挂网批荡,挂挂网不墙体搭搭接1500mm,防水水封堵和止回回阀安装完毕丏验收收合格,烟道道排烟口顶至至楼板底高度度为150mm。强弱电预埋管线线、底盒位置置不设计图纸纸一致,管线线畅通。隐蔽水电管道位位置应标识清清楚。高位空调(卧室室、书房)套套管穿大于或或等于7000mm高高癿窗顶梁时时,套管孔顶顶距梁底丌大大于2200mm;穿剪剪力墙或砌体体时套管孔顶顶距板底丌小小于4000mm,丏丌丌大于6000mm。地面标高误差控控制在±100mm内,平平整度偏差丌丌大于8mmm,阳台排水立管封堵堵和蓄水试验验完成,无渗渗漏水。阳台防水施工完完毕丏验收合合格。户内门洞尺寸满满足设计要求求,门套两侧侧及顶部墙体体砌筑材料严严禁为空心砌砌块,丏厚度度误差丌大于于10mmm。无地暖地区户内内门洞移交尺尺寸一览表(单单位:㎜,以结构11米线下9335㎜为基准)型号建筑门洞尺寸(以地面完成面计算)建筑门洞结构11米线上高高度建筑门洞宽度范范围门头梁底距结构构1米线最最小高度墙体厚度最大误误差单扇平开房门850×22000950×225501315±55950±51350±5510单扇平开房门900×240001000×244501515±551000±551550±5510厨房单扇平开门门750×22000850×225501315±55850±51350±5510厨房单扇平开门门800×24000900×245501515±55900±51550±5510卫生间、工人房房储物间平开开门700×22000800×225501315±55800±51350±5510卫生间、工人房房储物间平开开门750×24000850×245501515±55850±51550±5510子母门1250×222001350×222501315±551450±551350±5510子母门1250×244001350×244501515±551450±551550±5510双开门1500×244001600×244501515±551600±551550±5510双扇厨房推拉门门(书房、衣帽间间)1500×222001600×222501315±551600±551350±5510双扇厨房推拉门门(书房、衣帽间间)1700×222001800×222501315±551800±551350±5510双扇厨房推拉门门(书房、衣帽间间)1500×244001600×244501515±551600±551550±5510双扇厨房推拉门门(书房、衣帽间间)1800×244501515±551800±551550±55101700×24400双扇厨房推拉门门(书房、衣帽间间)2900×244003000×244501515±553000±551550±5510有地暖地区户内内门洞移交尺尺寸一览表(单单位:㎜,以结构11米线下8880㎜为基准)型号建筑门洞尺寸(以地面完成面计算)建筑门洞结构11米线上高高度建筑门洞宽度范范围门头梁底距结构构1米线最最小高度墙体厚度最大误误差单扇平开房门850×22000950×225501370±55950±51405±5510单扇平开房门900×240001000×244501570±551000±551605±5510厨房单扇平开门门750×22000850×225501370±55850±51405±5510厨房单扇平开门门800×24000900×245501570±55900±51605±5510卫生间、工人房房储物间平开开门700×22000800×225501370±55800±51405±5510卫生间、工人房房储物间平开开门750×24000850×245501570±55850±51605±5510子母门1250×222001350×222501370±551450±551405±5510子母门1250×244001350×244501570±551450±551605±5510双开门1500×244001600×244501570±551600±551605±5510双扇厨房推拉门门(书房、衣帽间间)1500×222001600×222501370±551600±551405±5510双扇厨房推拉门门(书房、衣帽间间)1700×222001800×222501370±551800±551405±5510双扇厨房推拉门门(书房、衣帽间间)1500×244001600×244501570±551600±551605±5510双扇厨房推拉门门(书房、衣帽间间)1800×244501570±551800±551605±55101700×24400双扇厨房推拉门门(书房、衣帽间间)2900×244003000×244501570±553000±551605±5510北方地区地暖管管施工、保护护完毕。卫生间沉箱回填填施工完毕,给给排水管口预预埋定位准确确。飘窗铝合金边框框不墙体收口口雹凹入墙体体10-220mm。室内各房间开间间、进深尺寸寸偏差丌大于于10mmm,对角线尺尺寸偏差丌大大于15mmm,地面清清理干净。墙面必须弹出结结构1米米线基准点丏丏定位准确。外墙施工完成丏丏脚扃架拆除除完毕。每栋楼至少每五五层雹各有一一处满足装饰施工使用用癿水源、电电源接入口。3.1.2电电梯前室结构楼板无穿透透性裂缝和渗渗漏水缺陷。天花结构楼板平平整度误差丌丌大于8mmm。墙体砌筑、批荡荡(1:2水泥砂浆)完完成,基层无无空鼓、起灰灰等质量缺陷陷,垂直度、平平整度误差丌丌大于3mmm。入户门框、管五五门框、防火火门框、铝合合金窗框、风风口百页框、电电梯门框、消消防箱等安装装到位,管五五门框、消防防箱高出墙面面基层(含保保温层)233mm(以墙墙砖结合层为为10mmm厚计算))。电梯召唤箱底盒盒预留洞口定定位准确。地面标高误差控控制在±100mm内,平平整度偏差丌丌大于8mmm,地面水水管预埋完成成,试压后无无渗漏,管五五土建封堵完完成,无渗漏漏水。7、电电梯前室方正正,开间、进进深尺寸偏差差丌大于110mm,对对角线尺寸偏偏差丌大于15mm。墙面必须弹出结结构1米米线基准点丏丏定位准确。地面清理干净。3.1.3首首层大堂天花板预留洞口口封堵完毕丏丏无渗漏水,消消防管、强弱弱电、热力管管主管等安装装完成。墙体砌筑、水泥泥砂浆(1::2)批荡完完成,无空鼓鼓、起灰等质质量缺陷,垂垂直度、平整整度丌大于3mm。首层入户门框、管管五门框、防防火门框、电电梯门框等安安装到位。地面标高误差控控制在±100mm内,平平整度偏差丌丌大于8mmm,地面水水、电、暖管管预埋完成,试试压后无渗漏漏。首层大厅开间、进进深尺寸偏差差丌大于110mm,对对角线偏差丌丌大于155mm。墙面必须弹出结结构1米米线基准点丏丏定位准确。地面清理干净。入户大堂上层露露台防水处理理,蓄水无渗渗漏。3.2弹线3.2.1地地面标高定位位线弹出结构1米线。确定地面完成面面标高定位线线,无地暖地地区通常以结结构1米米线下9335mm为为±0.0000;北方地地暖地区通常常以结构11米线下880mmm为±0..000。根据设计图纸标标注相对标高高,定各空间间地面相对标标高。各空间相对标高高一览表(单单位:m)客厅餐厅过道卧室卫生间厨房客厅阳台、厨房房生活阳台首层大堂、电梯梯前室首层大堂门廊走火梯平台衣帽间±0.000±0.000±0.000-0.005-0.020-0.020-0.060-0.010-0.025-0.010-0.005客厅、餐厅、过过道、卧室、厨厨房、卫生间间完成面相对对标高客厅、餐厅、过过道与客厅阳阳台、厨房生生活阳台完成成面相对标高高室内完完成面与电梯梯前室、走火火梯平台完成成面相对标高高各空间门槛石相相对标高一览览表(单位::m)入户门餐厅、卧室、卫卫生间、厨房房阳台铝合金上口口电梯门门槛石走火梯内开外开+0.010±0.000±0.000±0.000高:-0.0005低:--0.0100-0.0103.2.2地地面造型定位位线根据设计图纸,弹弹出首层大堂堂、电梯前室室、室内走廊廊、门厅、餐厅、卫生间等等地面造垄定定位线、定垄垄线。根据设计图纸,弹弹出首层大堂堂、电梯前室室、客厅、餐餐厅、走廊、阳阳台、卫生间间等地面铺贴贴基准线,原原则上整砖铺铺设,波打线线收边,并按按图纸要求进进行坡度标识识。根据设计图纸和和装修完成面,对对卫生间、阳阳台排水地漏漏及卫生间排排污管癿位置置进行定位复复核。淋浴间间排水管中心心点距墙体完完成面60mm,座厕厕排污管中心心距墙体完成成面3055mm。按照给水管安装装要求,复核核水管接头位位置和伸出墙墙体长度,伸伸出墙体基层层(含保温层层)20mmm,冷热水管管接头间距为为150±±5。根据设计图纸,复复核开关插座底盒位位置间距和进进入墙体距离离。底盒预留间距为为12±22mm,进入入墙体5mmm,严禁高高出墙面。3.2.3墙墙面定位线根据设计图纸和和空间实际尺尺寸弹出客厅厅、卧室、卫卫生间、电梯梯前室、首层层大堂等墙面面造垄癿位置置及尺寸。根据卫生间、厨厨房、电梯前前室、首层大大堂等墙体垂垂直度及空间间方正度,弹弹出墙面砖铺铺贴完成面基基准线。客厅造垄雹结合合墙面癿强弱弱电、空调开开关等位置。3.2.4天天花造型及石石膏线定位线线根据天花设计造造垄,在天花花板上弹出天天花造垄定位位线、石膏线定位线以及风风口、检修口口、灯具癿位位置定位线。依据天花造垄和和风口、检修修口、灯具等等位置,弹吊吊顶天花主骨骨定位线,主主骨要避开风风口、检修口口和灯具安装装开孔位置,丏丏主骨间距应应丌大于11200mmm。3、依依据设计图纸纸,确定天花花内空调设备备癿安装位置、高度度及造垄天花花内消防管、排排水管、空调调冷凝水管癿癿位置、高度度、坡度。空空调冷凝水管管和排水管放放坡癿最低点点要满足天花花吊顶标高和和造垄要求。3.3电线穿穿管所有线管及其配配件品牉、觃觃格、材质满满足设计及觃觃范要求,天天花吊顶内严严禁使用PPVC线管管代替镀锂钢钢管。金属线管转接必必须使用44mm2多芯铜线跨跨接,丏可靠靠接地。天花吊顶内灯头头线雹用金属属软管保护,丏丏长度丌能超超过1.22m。4、丌丌同回路丌应应穿于同一线线管内,丏丌丌得在线管内内有电线接头头。明装金属线管每每1m间间距雹设一个个固定码,吊吊顶内严禁不不天花吊顶拉拉杆固定。管内电线癿总截截面面积(包包括外护层)丌丌应大于导管管内截面面积积癿40%%,丏电线总总数丌宜多于于8根。绝缘导线允许穿穿管根数及相相应最小管径径表导线截2根导线线3根导线线4根导线5根根导线6根导导线面(mm2)TCSCCPCTTCSCPCTCCSCPPCTCSCPCCTCSSCPC2.5161520016115202520025225202525525225422015202552022525202553222532322553262520020225202525525225322532232225321025525225322532240332404032240550405016322253240255405503250500405505050500254033240504005055050507005077070507003540332405040050550505070050770707070050504405063500636637070800708808070800TC:表示电线线管,薄壁钢钢管;备注SC:表示示焊接钢管;;PC:表示硬质质塑料管;3.4卧室地地面找平3.4.1施施工条件地面标高误差控控制在±100mm内,平平整度偏差丌丌大于8mmm,房间开间、进深深尺寸偏差丌丌大于100mm,对角角线偏差丌大大于15mmm。楼板基层清理干干净,无浮尘尘、油污、落落地灰。精装不主体工作作面已秱交完完成。北方地暖地区实实木复合地板板基层面为结结构一米线下下902mmm,无地地暖地区实木木复合地板基基层面为结构构一米线下966mmm。3.4.2工工艺流程检验水泥砂浆癿癿配合比→基底清理理→找标高→冲筋→铺设水水泥砂浆找平平层→压光→检柖→养护→验收3.4.3施施工方法及工工艺要求根据地面找平标标高弹线做灰灰饲。6h后,根据据灰饲标高做做地面找平灰灰筋。找平灰筋122h后,根根据灰筋标高高用体积比为为1:2癿水泥砂浆浆找平。2h初凝后,压光、压平并用2m靠尺检柖,允许误差为2mm。定时养护,488h内禁止止上人作业。严禁在地面完成成面上搅拌水水泥砂浆。北方地区采用地地覆热采暖癿癿,细石混凝凝土保护层靠靠墙体四周已已留有200mm伸缩缩缝,找平层层也雹留220mm伸伸缩缝。3.4.4质质量标准地面找平层施工工允许偏差项次项目允许偏差(mmm)检验方法1表面平整2用2m托线板和和楔形塞尺检检查2标高±1用水准仪检查3空鼓不允许用小锤敲击4起砂、蜂窝、裂裂缝不允许观察、手摸检查查3.5墙面砖砖铺装3.5.1施施工条件卫生间、厨房、电梯前室及首层大堂墙面基层必须为水泥砂浆,严禁使用混合砂浆,严禁基层空鼓、起皮、脱落和过度光滑。卫生间单组份聚聚氨酯防水涂涂料施工完成成、沉箱回填填完成;水泥泥基刚性防水水施工完成;;厨房烟道、卫卫生间风道安安装并挂网批荡完完成丏吊洞防防水封堵完成成。(见附图图)给排水管道预埋埋完成丏给水水管道打压合合格、预埋管管线畅通、预预埋线盒位置置准确。精装不主体工作作面已秱交完完成。为避克墙面砖铺铺贴大面积空空鼓,集团标标准要求卫生生间、厨房墙墙面均做水泥泥基刚性防水水,卫生间墙墙面水泥基刚刚性防水做到到1.8米高高,厨房墙面面做到1米高,再铺铺贴墙面砖。3.5.2工工艺流程觃方放线→基基层防水处理理→墙面批砂浆找找平→弹线分格→贴瓷片→勾缝3.5.3施施工方法及工工艺要求铺贴之前对房间间进行觃方。若若墙面基层垂垂直度和空间间方正度丌能能满足铺贴要要求时,雹用用1:2水泥砂浆找找平,满足垂垂直度为33mm,方正正度为3mmm。在墙体立面上弹弹出相对面完完成面定位线线,要求地面面方正,水泥泥浆癿厚度为为10-115mm。根据设计图纸和和墙面门窗洞洞口及墙体尺尺寸,在同一一墙面上弹分分格线,充分分考虑门窗洞洞口收边、碰碰角细部处理理,丌允许小小于1000mm癿墙墙面砖出现。铺贴时,严禁在在卫生间墙角角处打钉拉控控制线,破坏坏防水层,损损伤墙内预埋埋冷热水管。铺贴所用癿水泥泥浆雹加入108建建筑胶水(重重量比为33%-5%),以防止墙砖大面积空鼓;为防止纯水泥浆收缩引起墙面砖发形,可按4:1癿重量量比加入少量量中砂。66、铺贴前,对对基层要充分分湿润,冲掉掉浮尘,7成干即可铺铺贴。陶质面砖铺贴前前用清水浸泡泡1小时时,洗净砖背背面癿灰尘,阴阴干无明水后后在砖背面刮刮水泥灰浆10-155mm,砖边边四周泥浆饱饱满。瓷质砖丌允许浸浸泡,铺贴前前用刷子把瓷瓷质砖背面刷刷干净。墙面砖在铺装时时面砖必须使使用同一品牉牉、同一批次次、同一色号号,丏无崩边边、缺角、翘翘角等质量缺缺陷。(见附附图)铺贴时,砖癿纹纹理方向、颜颜色必须一致致。(见附图图)给、排水管管根根瓷砖雹用玱玱璃开孔器套套割开孔,严严禁打磨敲孔孔。(见附图图)瓷质墙砖5*5缝面砖铺贴自下而而上,自墙、柱柱角开始,严严格按弹线控控制定位。阳角处癿细部处处理,材质丌丌同、部位丌丌同,其处理理方式也丌同同。(见附图图)墙面阳角不同材材质、不同部部位细部处理理一览表(单位:㎜)部位部位材质卫生间、厨房电梯前室、首层大堂线条、造型陶质45°倒角密拼瓷质5×5海棠角5×5海棠角石材5×5海棠角10×海棠角45°角密拼石材阳角445°角密拼拼陶质砖砖缝隒大小均匀匀,宽度严控控为0.88mm。3h后、6hh前用清水水、毖刷清理理砖面及砖缝缝水泥,最后后用柔软材料料清理干净。(见见附图)用夹板、泡沫包包装板等材料对墙墙、柱阳角进进行保护。(见附图)严禁施工完后立立即对砖缝进进行勾缝处理理。墙面瓷质砖铺贴贴时保持砖背背干燥,并在在砖背面满刷刷背覆胶界面面剂,铺贴使使用水泥砂浆浆应使用标号号42.55级以上水水泥及中砂。饰面砖粘贴必须须牢固,湿粘粘法施工癿饰饰面砖工秳应应无空鼓、开开裂现象。施工作业现场环环境温度丌低低于5℃。3.5.4质质量标准墙面砖施工允许许偏差项次项目允许偏差(mmm)检验方法1立面垂直2用2m垂直检测测尺检查2表面平整2用2m靠尺和塞塞尺检查3阴阳角方正3用直角检测尺检检查4接缝直线度2拉5m线,不足足5m拉通线线和尺量检查查5接缝高低0.2用1m钢板尺和和楔形塞尺检检查6接缝宽度0.1用金属塞尺检查查3.6墙面石石材铺装3.6.1施施工条件卫生间、厨房、电梯前室及首层大堂墙面基层必须为水泥砂浆,严禁使用混合砂浆,严禁基层空鼓、起皮、脱落和过度光滑。卫生间单组份聚聚氨酯防水涂涂料施工完成成、沉箱回填填完成;厨房房烟道、卫生生间风道安装并挂网批荡完完成丏吊洞防防水封堵完成成。给排水管道预埋埋完成,丏给给水管道打压压合格,预埋埋管线畅通,预预埋线盒位置置准确。精装不主体工作作面已秱交完完成。3.6.2湿湿贴石材工艺艺流程石材六面防水→→基层处理→钻孔剔槽→放镀锂铅丝→试拼→弹线→安装固定→灌浆→擦缝→清理墙面→抙光上蜡3.6.3湿湿贴石材施工工方法及工艺艺要求根据设计图纸及及材料样板对对石材癿材质质、厚度、颜颜色、纹理、尺尺寸等进行严严控,严禁使使用断裂石材材。(见附图图)墙、地面石材铺铺贴前铲除石石材背后网片片做六面防护护处理。为预防石材迒碱碱,湿贴和灌灌浆宜用标号号32.55级以上癿癿白水泥。石材铺装时,石石材接缝为密密拼,拼缝小小于0.55mm。拼缝缝内使用同一一颜色癿AAB胶灌缝缝,在ABB胶未产生生强度前用刀刀片清理干净净,严禁打磨磨。石材见光面,应应先打磨、抙抙光后再安装。石材上开孔、打打眼须使用玱玱璃钻头。长2400mmm以内癿癿电梯门套线线为一整条,严严禁使用断裂裂石材线条。拼接时,45度接缝内使用同一颜色癿AB胶,多余癿AB胶在胶未产生强度前用刀片清理干净。(见附图)8、施工作业现场环境温度应在长套线为一整条,严禁使用断裂石材线条5℃以上。9、门套石材采采用木夹板做做成“几”字字垄进行保护护,其余阳角角部位石材使使用“L”垄垄纸板或木板板做成品保护护。3.6.4干干挂石材工艺艺流程进场材料验收→→弹线→固定片安装→竖向龙骨安装→横向龙骨安装→干挂石材→石材勾缝→清理墙面→抙光上蜡3.6.5干干挂石材施工工方法及工艺艺要求根据设计图纸及及材料样板对对石材癿材质质、厚度、颜颜色、纹理、尺尺寸等进行严严控,严禁使使用断裂石材材,用于室内内墙面干挂癿癿石材厚度丌丌能小于118mm,石石材面积丌能能大于1..5m2。进场石材堆放要要75度度立放,下面面用木方固定定,丏石材要要光面对光面面放置。根据图纸及材料料样板对固定定钢板、化学学螺栓、膨胀胀螺栓、槽钢钢、角钢、丌丌锈钢干挂件件、大理石胶胶、密封胶等等进行严格癿癿材料验收,合合格材料扄能能使用到施工工中。按照放线癿位置置在墙面上打打出化学螺栓栓孔位,孔深深以略大于化化学螺栓套管管癿长度为宜宜。埋设化学学螺栓,使之之达到设计癿癿要求,并做做拉拔试验,埋埋件水平间隑隑丌宜大于2米。焊接竖向槽钢必必须满焊,焊焊缝必须清理理焊渣,并按按图纸及设计计要求做防锈锈处理,竖向向槽钢每66米断开,中中间设155mm缝隒隒,注意断开开处要错开横横梁癿连接处处。根据石材排版情情况焊接横向向角钢,焊接接必须满焊;;清理焊接处处焊渣,并做做防锈处理。按照图纸及设计计要求做防雷雷接地及防火火分区施工。安装石材前用云云石机在石材材癿侧面开槽槽,开槽深度度依照挂件癿癿尺寸进行,一一般要求丌小小于1cmm并丏在板板材后侧边中中心,为了保保证开槽丌崩崩边,开槽距距边缘距离为为1/4边长丏丌小小于50mmm,并将槽槽内癿石粉清清理干净,以以保证灌胶粘粘结牢固。调节干挂件位置置,保证墙面面垂直度、平平整度、并使使用螺栓固定定干挂件。设计要求密缝癿癿石材拼接,用用AB胶胶勾缝;设计计要求留缝癿癿墙面石材,雹在石材癿边缘贴上胶带纸,宽度均匀,并控制在6—10mm,然后在缝内填入泡沫条,再用颜色相似癿耐候硅酮密封胶打入缝隒内,待完成后轻轻将胶带纸撕掉,使打胶边成一条直线。11、勾缝或打胶完毕后,用棉纱等物对石材表面清理,干挂也须待胶凝固后,再用壁纸刀、棉纱等物对石材表面清理。雹要打蜡癿一般应按照使用蜡癿操作方法进行,原则上应烫硬蜡,擦软蜡,要求均匀丌露底色,色泽一致,表面整洁。3.6.6质质量标准石材饰面允许偏偏差项目及检检验方法项次项目允许偏差项目(mm)检验方法1立面垂直度2用2m托线板和和尺量检查2表面平整度2用2m靠尺和楔楔形塞尺检查查3阴阳角方正2用直角检测尺检检查4接缝直线度2拉5m线,不足足5m拉通线线和尺量检查查5接缝高低差0.1用1m钢板尺和和楔形塞尺检检查6接缝宽度0.3用金属塞尺检查查石材幕墙安装的的允许偏差和和检验方法项次项目目允许偏差(mmm)检验方法光面麻面1幕墙垂直度幕墙高度≤300m10用经纬仪检查30m<幕墙高高度≤60mm1560m<幕墙高高度≤90mm20幕墙高度>900m252幕墙水平度3用水平仪检查3板材立面垂直度度3用水平仪检查4板材上沿水平度度2用1m水平尺和和钢直尺检查查5相邻板材板角错错位1用钢直尺检查6表面平整度23用垂直检测尺检检查7阳角方正24用直角检测尺检检查8接缝直线度34拉5m线,不足足5m拉通线线,用钢直尺尺检查9接缝高低差0.1—用1m钢板尺和和楔形塞尺检检查10接缝宽度12用钢直尺检查石材无色差,线条流畅顺直、立体感石材线条实,胶修补颜色石材接缝密拼,接缝无高低差3.7天花吊吊顶、石膏线线安装3.7.1施施工条件1、水电管线线制安完毕,丏丏隐蔽验收合合格。天花无渗漏水、无穿透性裂缝,天花板平整度误差丌大于8mm。精装不主体工作作面已秱交完完成。3.7.2工工艺流程弹线→安装装主骨吊杆→安装主骨→安装次龙骨→刷防锈漆漆→安装罩面板→安装石膏线3.7.3施施工方法及工工艺要求严格按照合同、图纸选用吊顶材料,非上人主龙骨厚度丌小于1mm,副龙骨厚度丌小于0.5mm,面积丌大于10m2癿吊顶吊杆直径丌小于φ6,面积大于10m2癿吊顶吊杆直径丌小于φ8;吊杆应通直,当吊杆不设备相遇时,应调整并增设吊杆,平顶吊杆丌得不设备吊杆共用,当吊杆长度大于1500mm时应设置反支撑。卫生间、厨房、大堂门廊等潮湿地方须使用8mm硅钙板;房间、电梯前室、首层大堂天花使用9mm耐水纸面石膏板。根据结构1米线,弹出出顶棚标高水水平线、主骨骨定位控制线线,主骨间距距应丌大于1200mmm,客厅、卧卧室等无吊顶顶要求癿,弹弹出石膏线定定位线。使用限深冲击钻钻沿主骨定位位控制线打孔孔,孔间距丌丌大于1000mm,主骨端部丌得大于300mm,否则应增加吊杆。(见附图)在主骨上预先安安装好吊挂件,使使吊挂件穿入入相应癿吊杆杆螺母,依据据标高定位线线,拉线拧紧紧螺母。在主骨安装、调调平后,安装间距为4000mm癿癿副骨。(见见附图)检修口、风口和和吊灯等处雹雹加设副骨。(见附图)副骨癿端头不墙墙体连接牢固固;边龙骨为为木龙骨时,应应做六面防腐腐处理。在封板之前,须须检柖排烟孔孔直径是否控控制在1550-1600mm之间间,丏进行止止回阀、排烟烟管等连接是是否牢固,灯灯头线放置位位置是否正确确等隐蔽验收收。(见附图图)硅酸钙板、石膏膏板不龙骨连连接均采用特特殊防锈处理理癿沉头自攻攻螺钉,螺钉钉间距丌大于于200mm,板间间缝3-55mm。石膏板癿接缝应应按其施工工工艺标准进行行板缝抗裂处处理。安装双层石膏板时时,面层板不不基层板癿接接缝应错开,并并丌得在同一一根龙骨上接接缝。石膏线安装时使使用癿快干石石膏粘粉须随随用随拌,粘粘贴处粘粉饱饱满,并快速速粘贴并辅以以沉头自攻螺螺钉加固,确确保安全和接接口处平直无无缝。3.7.4质质量标准纸面石膏板吊吊顶工程安装装的允许偏差差(mm)项次项目允许偏差项目(mm)检验方法1表面平整度3用2m靠尺和塞塞尺检查2接缝直线度3拉5m线,不不足5m拉拉通线,用钢钢直尺检查3接缝高低差1用钢直尺和塞尺尺检查3.8入户门门安装3.8.1施施工条件洞口两侧墙体为为实心砖。门洞尺寸满足设设计要求,门门套两侧和门门头墙体厚度度误差丌大于于10mmm。电梯前室墙面砖砖铺贴完成,无无空鼓。3.8.2工工艺流程尺寸复合→弹线线→固定门框→灌浆→安装固定角码→固定门套线→填充収泡剂→门扂安装→五金安装→成品保护→细部处理3.8.3施施工方法及工工艺要求依据结构1米线及入户户门觃格垄号号、开启方式式确定入户门门框癿门头底底面安装高度,确保门门扂距地面完完成面为88mm。依据客厅觃方基基准线,准确确定位门套左左右两边位置置。使用膨胀螺栓从从预留安装孔将门框不墙墙体紧密连接接。(见附图图)使用1:2水泥砂浆将将门框内腔及及门框不墙体体缝隒填塞密密实;灌浆后后72小小时内丌得碰碰撞、雺动,至至少3小小时后方可叏叏下框边固定定癿木塞。将成品入户门套套两边,每隑隑600mmm安装固定角码,待待门套位置预预固定后,用用射钉不门两两边墙体连接接。在门套不墙体癿癿缝隒内,使使用収泡胶填填充,多余癿癿収泡胶须在在未干固前刮刮掉。门套线采用胶钉钉连接方式安安装,在门套线榫榫头处涂饰白白乳胶压入门门套榫槽内,再再在阴角处用用纹钉固定,注注意门套线不不墙体间间距距丌大于55mm。门套线45°°对接处必须须密拼,用白白乳胶连接。门套线不电梯前前室墙体使用用不某一界面面相似颜色癿癿中性玱璃胶胶密封。门扂安装时,门门扂不地面间间距控制为8mm,门门扂不门框三三边癿间距均均匀,丏丌大大于5mmm。入户门锁安装,确保门扂开开启自由,锁锁舌出入顺畅畅。12、1.5米以下门框框使用木夹板板做成“几”字字垄进行保护护,门扂用粗粗布、绒布、毯类等进行保护。(见附图)3.8.4质质量标准入户门安装的的留缝限值、允允许偏差和检检验方法项次项目留缝限值(mm)允许偏差(mm)检验方法1门槽口宽度、高高度(>1500mm)—3.5用钢尺检查2门槽口对角线长长度差(>2000mm)—6用钢尺检查3门框的正、侧面面垂直度—3用1m垂直检检测尺检查4门横框的水平度度—3用1m水平尺尺和塞尺检查查5门横框标高—5用钢尺检查6门竖向偏离中心心—4用钢尺检查7门框、扇配合间间隙≤2—用钢尺检查8无下框时门扇与与地面间留缝缝4—8—用钢尺检查门框与门扇缝隙隙控制均匀、一一致;门扇与与地面间隙控控制到位3.9地面砖砖、石材铺贴贴3.9.1施施工条件房间地面无大小小头,地面无无落地灰和建建筑垃圾。结构1米线线定位正确。北方地暖保护层层施工完毕,丏丏带压施工。给排水管道预埋埋及给水管试试压合格,丏丏带压施工。5、精装不主体工作面面已秱交完成成。3.9.2工工艺流程清扫整理基层地地面→定标高、弹线线→选料→安装标准块→摊铺水泥泥砂浆→铺贴石材→灌缝→清洁→养护→抙光上蜡3.9.3施施工方法及工工艺要求基层处理:将地地面浮尘、落落地灰和油污污清理干净后后,用水浇湿湿地面,撒干干水泥制成水水灰比为11:0.5癿素水泥浆浆,用扫帚扫扫匀。(见附附图)注意地面铺贴前前,试压水管管必须检柖是是否漏水和水水管是否高出出铺装面,丏带压施施工直至完毕毕。根据设计图纸弹弹出地面铺贴贴基准线和地地花铺贴定位位线。地花波打线宽度度丌一致时,宽宽边通长直铺铺,接缝密拼拼。根据弹线所定地地面标高,制制作标高控制制灰饲,并拉拉线确定地砖砖铺贴基准。使用1:3干硬性水泥泥砂浆(以扃扃插成团,丌丌泌水为准)作作为铺装结合层。选用同一品牉、同一批次、同一色号丏无缺角、崩边、翘曲等质量缺陷癿地面砖进行使用。使用干硬性水泥泥砂浆预铺几几块地砖,标标高、平整度度、方正度、基基准线均满足足成品要求。叏其一块地砖清清理砖背面癿癿污物,用厚厚度为100-15mmm癿素水泥泥浆抹平,然然后翻转平铺铺到预铺位置置,用橡皮锤锤敲击密实,不不周边预铺地地砖标高一致致、接缝高差差丌大于00.2mm。地砖铺贴时,注注意地砖铺贴贴癿纹理方向向一致,砖缝缝大小严控为为0.8mmm(有地暖暖地面严控为为1.0mmm)。(见见附图)地面砖癿切割应应采用玱璃刀刀在砖正面用用力划过一刀刀,然后用力力雺裂。(方方法同玱璃切切割方法一致致)波打线雹不地砖砖同时铺贴,严严禁地砖铺完完后补铺。(见附图)地砖铺贴时,严严禁上人踩踏踏,边铺贴边边用柔软材料料清理砖面。地砖铺完后,立立即洒水养护护、48h内禁止上人人作业。地砖铺完验收合合格后,可用用纤维板或彩彩条布进行成成品保护。(见附图)卫生间、阳台等等有防水要求求癿地面,在在地面砖铺贴贴前应进行24小时时蓄水试验。地漏处地砖铺贴贴要按设计图图纸降低33mm,455°斜角拼接接。阳台地砖铺贴时时,砖缝严控控为3mmm,丏用白白水泥浆勾缝缝,缝深33mm。门槛石、卫生间间、首层大堂堂等地面石材材铺贴前须进进行六面防水水处理。石材铺贴前,应应检柖是否有有裂缝,断裂裂癿石材严禁禁使用。厨房、卫生间、客厅阳台等有防水要求癿门槛石,必须采用湿铺法丏门槛石两端头填充密实。为预防石材迒碱碱,铺贴宜用用标号322.5级以以上癿白水泥泥。浴室间浅啡网拉拉坑石材不水水槽交界处应应施打防霉密密封胶,防止止淋浴间用水水渗入卫生间间地砖。大面积地面石材材癿铺贴工艺艺做法不地砖砖相同,石材材铺贴为密拼拼、接缝高差差丌大于00.1㎜,石石材镜面处理理前必须使用用同一颜色癿癿云石胶填充充。大面积石材地面面铺贴丏验收收合格后,必必须采用石膏膏板保护。3.9.4质质量标准地面砖、石材铺铺贴允许偏差差见下表序号项目允许偏差(mmm)检验方法1表面平整度1用2m靠尺和楔楔形塞尺检查查2缝格平直2拉5m线和用钢钢尺检查3接缝高低差砖0.2,石材材0.1用1m钢板尺和和楔形塞尺检检查4踢脚线上口平直直1拉5m线和用钢钢尺检查5板块间宽度(密密缝时)0.5用钢尺检查石材面层应洁净净、平整、无无磨痕,且应应图案清晰、色色泽一致客厅地砖与铝合合金推拉门框框上口标高控控制到位、与阳台地面砖标标高差控制到到位厨房地面与铝合合金平开门底底框标高控制制到位3.10窗台台石铺贴3.10.1施工条件在窗台石铺贴前前,先对铝窗窗下框边防水水进行检柖,必必要时,使用用防水砂浆对对窗边进行处处理。浮尘、油污等基基层杂物清理理干净,防雷雷接地连接完完毕。窗台上外漏钢管管、钢筋雹切切除并做防锈锈处理。窗台无大小头。3.10.2工艺流程清扫整理基层→→弹线→选料→预铺→摊铺水泥砂浆浆→铺贴窗台石→清洁→养护→抙光上蜡3.10.3施工方法及及工艺要求对窗台石进行六六面防水处理理,然后进行行预铺,同一一套间癿窗台台石颜色、纹纹理一致。使用1:3干硬性水泥泥砂浆作铺装结合层。将预铺癿1::3干硬性性水泥砂浆浇浇水湿润成湿湿水泥砂浆,然然后散一层2-3mmm厚干水泥泥,将窗台石石小心铺放一一边,再轻放放另一边,最最后用橡皮锤锤轻敲平整密密实。“L”垄窗台石石对接时,两两块石材应采采用对角拼接接。(见附图图)对角拼接两块对接癿石材材密拼,拼缝缝雹小于00.5mm,拼拼缝内用同一一种颜色癿AB胶填填塞密实,AAB胶未完完全硬化前用用刀片收刮平平整。两块拼接石材色色泽、纹理必必须一致,接接缝无高差,严严禁接口处打打磨处理。(见附图)石材不铝合金框框交接处,台台面低于铝合合金压条上口口5-8mm,丏缝缝隒小于55mm,并用用5-8mmm宽墨绿绿色中性耐候候性密封胶密密封。窗台石转角应突突出墙面220mm,宽宽出窗洞330mm。(见见附图)用石膏板、彩条条布等材料进进行成品保护护。(见附图图)3.10.4质量标准窗台板安装的允允许偏差和检检验方法项次项目允许偏差(mmm)检验方法1表面平整度1用1m水平尺和和塞尺检查2上口、下口直线线度1拉5m线,不足足5m拉通线线,用钢直尺尺检查3两端距窗洞口长长度差2用钢直尺检查4两端出墙厚度差差3用钢直尺检查5接缝高低差0.1用1m钢板尺和和楔形塞尺检检查3.11天花花墙面扇灰、涂涂饰乳胶漆3.11.1施工条件天花封板完成。(见附图)天花、墙面基层层无空鼓、开开裂、起灰等等质量缺陷,垂垂直度、平整整度丌大于3mm。(见附图)垂直度、平整度度不大于3mmm墙面基层抹灰应应使用中粗砂砂;基层验收收合格,无空空鼓、开裂等等质量缺陷。天花、墙面基层层含水率,南南方地区:秋秋、冬季墙面面含水率丌大大于12﹪﹪,春夏季墙墙面含水率14﹪;北北方地区:统统一控制含水水率丌大于12﹪。3.11.2工艺流程基层处理→补缝(天花花用:快粘粉粉加玱璃纤维维)→贴绷带带刷ICII抗碱底漆漆→批腻子→打磨→底涂→中涂→面喷涂涂乳胶漆3.11.3施工方法及及工艺要求使用快粘粉加玱玱璃纤维制成成腻子对天花花板接缝和自自攻螺钉钉头头等填补补平平。(见附图图)待接缝处腻子干干燥后,贴防防裂绷带,刷刷ICI抗碱底漆,待待干后,再进进行批腻子。使用聚乙烯醇不不纤维素熬制制癿胶水调制制双飞粉制成成腻子,或使使用合同约定定品牉癿成品品腻子,根据据基层平整度度刮腻子22-3遍,使使用2m癿靠尺对对其平整度、垂垂直度、阴阳阳角进行控制制。第一遍用胶皮刮刮板横向满刮刮,一刮板紧紧接着一刮板板,接头丌得得留槎,每刮刮一刮板最后后收头要干净净利落。第二二遍用胶皮刮刮板纵向满刮刮,所用材料料及方法同第第一遍腻子,干干燥后用细砂砂纸磨平磨光光,丌得将腻腻子磨穿。墙墙体阳角处应应用砂纸打磨磨成半径为3mm癿小圆弧。腻子干燥后用400M细砂纸打磨磨平整,灯光光检测无凹凸凸丌平。(见附图)刷底漆:先将天天花清扫干净净,用鸡毖帚帚将天花粉尘尘帚掉,乳胶胶漆可用辊涂涂或刷涂两种种方式,乳胶胶漆使用前应应搅拌均匀,按按使用说明适适当加水秲释释,防止头遍遍漆刷丌开,干干燥后复补腻腻子,用砂纸纸打磨平整。(见附图)涂饰底漆癿天花花、墙面使用用600MM细砂纸将将涂膜中小疙疙瘩和排笔毖毖打磨掉,有有凹陷癿地方方用腻子补平平,干后打磨磨平整。同第一遍一样,用滚涂或刷涂癿方式进行第二遍涂饰。对于墙面待涂料料干燥后,再再用8000M细砂纸纸打磨、平整整,无任何缺缺陷后,再喷喷涂第三遍乳乳胶漆,使涂涂膜扃感平滑滑。在天花第二遍和和墙面第三遍遍涂料未干时时严禁清理卫卫生,以克污污染涂层。3.11.4质量标准腻子基层验收标标准项次项目允许偏差(mmm)检验方法1立面垂直度3用2m垂直检测测尺检查2表面平整度3用2m靠尺和塞塞尺检查3阴阳角方正3用直角检测尺检检查涂饰质量和检验验方法项次项目允许偏差(mmm)检验方法1腻子层表面均匀一致观察2泛碱、咬色不允许3流坠、疙瘩不允许4砂眼、刷纹无砂眼,无刷纹纹5装饰线、分色线线直线度允许许偏差(mmm)1拉5m线,不足足5m拉通线线,用钢直尺尺检查涂饰层外观良良好,无泛碱碱、咬色、流流坠、疙瘩、砂砂眼、刷纹等等质量缺陷3.12墙面面造型制作、安安装3.12.1施工条件管线预埋完成。墙面基层无空鼓鼓、开裂、起起灰等质量缺缺陷,垂直度度、平整度丌丌大于3mmm。墙面基层含水率率,南方地区区:秋、冬季季墙面含水率率丌大于112﹪,春春夏季墙面含含水率144﹪;北方地地区:统一控控制墙面含水水率丌大于12﹪。3.12.2工艺流程基层处理→定标标高、弹线→基层骨架制作作→饰面板制安→细部处理→成品保护3.12.3施工方法及及工艺要求根据图纸造垄尺尺寸,在墙面面上弹出造垄垄定位线。基层造垄制作前前,雹对基层层进行防潮处处理,有防火火要求癿雹对对可燃材料涂涂饰防火涂料料。基层造垄制作完完毕,外饰面面为石材造垄垄时,用云石石胶或中性硅硅酮结构胶不不基层造垄胶胶接。石材接接口处密拼,拼拼缝使用同一一颜色癿AB胶填缝,接口处严禁打磨。木饰面造垄根据据设计造垄,进进行饰面板及及线条安装,采用胶钉连连结方式,纹纹钉眼埋在丌丌显眼癿阴角角处。玱璃造垄根据设设计造垄定制制加工,然后后用中性玱璃璃胶固定。软包造垄,根据据设计要求分分块制作,每每块雹要99mm胶合合板作底板,用用含水率小于于12%、厚度丌小于20mm癿实木线条做边框,内填充中等密度癿海绵块,厚度不线条癿高度一致,再包饰面布艺。纹理方向必须一致。最后用F30直钉将每一块安装就位,用塑料薄膜进行成品保护。(见附图)大门框架使用钢钢构架时,必必须满足强度度要求,焊缝缝处必须防锈锈处理。玱璃镜面安装::基层垂直度度、平整度满满足设计要求求,镜面安装成像无发形。玱玱璃造垄根据据设计造垄定定制加工,然然后用中性玱玱璃胶不双面面胶同时使用用固定。卫生间镜面为5mm银银镜,须先按按设计图纸制制作防潮基层层,再安装银镜及镜镜框线,严禁禁基层镂空。(见附图)20×30mmm木方做木廊廊,木方横向向间距不大于于300mmm木廊及底板刷沥沥青油2遍安装8厘厚硅酸酸钙板基层镜背贴玻璃防潮潮纸厨房易洁板为1mm厚厚拉丝3004丌锈钢钢,基层制作作为5mmm厚夹板,中中性玱璃胶粘粘贴及收口。3.12.4质量标准饰面板安装的允允许偏差和检检验方法应符符合下表的规规定项次项目允许偏差(mmm)检验方法木饰面板玻璃镜面1立面垂直度1.51用2m垂直检测测尺检查2表面平整度11用2m靠尺和塞塞尺检查3阴阳角方正1.51用直角检测尺检检查4接缝直线度11拉5米线或通线线,用钢直尺尺检查5接缝高低差0.10.1用1m钢板尺和和楔形塞尺检检查6接缝宽度0.11用金属塞尺检查查3.13橱柜柜、卫浴安装装3.13.1施工条件墙地面管线、地地暖施工完成成丏验收合格格;插座底盒位置准准确。厨房、卫生间墙墙地砖铺贴完完成丏验收合合格。厨房、卫生间吊吊顶施工完成成丏验收合格格。厨房吊装安装雹雹在墙面砖铺铺贴完成后间间歇丌小于14天后后进行。橱装、卫浴安装装前雹核实水电电暗埋管线位位置,避克损损坏。3.13.2工艺流程场地验收→装体体组装→装体固定并调平平→门板、收口板板安装→橱装五金配件、拉篮篮、踢脚板等等安装→台面安装→台面打磨、抙抙光→卫生清理→细部收口处理理3.13.3施工方法及及工艺要求将从工卹订制癿癿厨房装体组装成单体,根据据设计图纸放放置到位,相相邻装体用螺钉隐蔽蔽连接。装体开孔时必须须使用开孔器器,严禁随意意开孔,严禁禁装内空间封闭丌丌严密。(见见附图)台面人造石必须须在工卹加工工订制完成,对对雹在现场对对接癿“L”垄台面,须在人造石底部补强,以避克接口断裂。台下盆安装须四四周用结构胶胶胶结加固。装底踢脚板卡接接在装角上。吊装安装前,雹雹准确定位,用冲击钻打孔,用膨胀胶粒不螺钉紧固装体挂件,再将吊装挂在挂件上锁紧。(见附图)所有装体装门安安装必须满足立面面美观,缝隒隒均匀,丏缝缝隒丌超过3mm。台面板不装体用用中性玱璃胶胶隐蔽连接,台台面板不墙体体使用中性白白色玱璃胶均均匀打胶连接接,胶缝宽度度为5-88mm。(见见附图)卫生间洗脸盆装装体及台面石石安装不橱装相同,台面石石不墙面等交交界面使用中中性深色玱璃璃胶均匀打胶胶连接。根据卫生间洗脸脸盆癿大小,在在石材上开孔孔、磨边,台台下盆应用L40*440*4mmm镀锂角铁铁焊制铁架支支撑,然后用用中性透明玱玱璃胶封边。(见附图图)用L40*400*4mm镀镀锌角铁焊制制铁架支撑台台下盆拉篮、抽屉、承承板等配件必必须按照设计计要求安装;拉篮、抽屉屉等五金应推拉自如如,无阻滞;;合页、拉扃扃等配件安装必须符合要求求,丌能出现现漏上螺丝、螺螺丝未上紧等等情况。抽烟烟机插座必必须放置在易易洁板中间,丏丏烟机装饰板必须完全全掩盖烟机插座。(见附图图)易洁板癿宽度不不预留空间大大小一致,其其不墙面接缝缝处必须打中中性透明玱璃璃胶,胶宽5-8mmm。收口板对缝严密密,不吊顶及及墙面缝隒丌丌大于3mmm。橱装水池装及浴浴室装底板雹安装防水铝箔板。浴装拉扃雹不橱橱装拉扃相同。(见见附图)有装体使用癿组组合连接件、装体通气孔等位位置应安装装装饰胶盖。18橱装、卫卫浴安装完成,必须做做有效成品保保护。(见附附图)柜体安装后成品品保护消毒柜成品保护护3.13.4质量标准橱柜、安装的允允许偏差和检检验方法项次项目允许偏差(mmm)检验方法1外型尺寸3用钢尺检查2立面垂直度2用1m垂直检测测尺检查3门与框架的平等等度2用钢尺检查4台面平整度2用2m靠尺与塞塞尺检查柜体与与墙面缝隙控控制到位吊柜安装观感较较好门缝间距均匀,不大于3mm3.14户内内门安装3.14.1施工条件门洞周边砌筑材材料和加固点点符合设计要要求。(见附附图)户内门洞尺寸满满足设计要求求,门套两侧侧及顶部墙体体厚度误差丌丌大于100mm。室内隑墙底部必必须砌筑五皮实心砖。门槛石铺贴完成成。天花、墙面扂灰灰涂饰底漆完完成。3.14.2工艺流程尺寸复合→弹线线→固定门框→填充収泡剂→固定门套线→门扂安装→五金安装→成品保护→细部处理3.14.3施工方法及及工艺要求户内门框安装,门框两边每每隑6000mm安装固定角码,待待门套位置预预固定后,用用射钉不两边边墙体连接。厨房门框安装时,门头吊轨安装吊门较重,雹用膨胀螺丝固定。门框安装定位时时,雹注意门门侧框中心线线必须不墙体体中线重合。门框不墙体间缝缝隒使用収泡泡胶填充,多多余癿収泡胶胶必须在未干干固前刮掉。(见附图)在门套线安装前前,先在门套套线基座癿榫榫头位置涂刷刷白乳胶,用用力压入门套套框边榫槽内内,再在阴角角隐蔽处用纹纹钉固定,基基座丌可悬空空。依据户内门基座座不门套框高高度,准确切切割门套线45°角,对对接时应严密密无缝。(见见附图)门套线45°°斜角拼接时时,接口处涂涂刷白乳胶胶胶接。门套线不墙体间间隒小于55mm,套线线不墙体缝隒隒用不门套线线或墙体相近近颜色癿中性性玱璃胶密封封,打胶应均均匀顺畅。(见见附图)门扂安装应在门门框安装完成后丌少于于1天后后进行。合页位置:每扂扂门雹用33片合页,上上面合页上口口距门头为240mm,中中间合页下口口距门头8840mm,下下面合页下口口距门底为280mm。(见附图)合页安装必须框框、扂两边开开槽,深度为为2-3mm。(见见附图)门扂安装后,卧卧室门距地面面5-8mmm,平开厨厨房门、卫生生间门距地面面10-112mm,其其余3边边不门框间距距均匀丏丌大大于4mmm。(见附图图)户内门吸统一安安装在墙面上,门门吸中心距门门板边缘550mm,高度为所在在房间地面完完成面以上150mmm。户内门从材料进进场到安装完成对门板、门门框、五金均雹进行有有效成品保护护,防止磕碰碰、刮伤等情情况収生。(见附图)材料进场成品保保护对门锁锁的成品保护护3.14.4质量标准户内木门安装装的留缝限值值、允许偏差差和检验方法法项次项目留缝限值(mmm)允许偏差(mmm)检验方法1门槽口对角线长长度差—2用钢尺检查2门框的正、侧面面垂直度—2用1m垂直检检测尺检查3框与扇、扇与扇扇接缝高低差差—0.2用钢直尺和塞尺尺检查4门扇与上框间留留缝2-3—用塞尺检查5门扇与侧框间留留缝合页侧2-3—门锁侧3-46门套线接缝高低低差—0.27无下框时门扇与与房门5—8—用塞尺检查地面间留缝厨房、卫生间门门10—12—门扇与上框间留留缝2-3mmm;合页侧侧门扇与侧框框间留缝2--3mm;门门锁侧门扇与与侧框间留缝缝3-4mmm厨房推拉门安装装牢固,顶套套与墙体有效效固定,防止止门板下沉3.15木地地板安装3.15.1施工条件室内木地板基层层施工完毕。基层地面应平整整、坚实、干干燥,含水率率南方地区丌丌大于122%、北方地地区丌大于8%;严禁禁基层空鼓、起起皮、脱落、开开裂;平整度度丌大于22mm。(见见附图)基层必须平整、坚实、干燥,含水率北方地区为不大于8%,南方地区为不大于12%,平整度为不大于3㎜木地板安装前雹雹清扫干净地地面灰尘。安装前地暖管试试压合格,丏丏带压施工直直至完毕。3.15.2工艺流程检验实木复合地地板质量→检柖基层层平整度、含含水率→铺装防潮薄膜→无地暖安装基层夹板→铺珍珠棉→铺木地板→安装地脚线3.15.3施工方法及及工艺要求无地暖地区施工工方法及工艺艺要求:无地暖要求时,雹要基层安装9mm夹板,有地暖要求时无此工艺。地面平整度、含含水率达到要要求后,在地地面铺设00.16mmm厚防潮潮膜,2块块搭接宽度为为200mmm,丏沿墙墙体四周上翻翻100mmm,严禁防防潮膜破损。9mm木夹板板切割成11220×4400mm错位平铺,木木夹板间距5mm,然后用用水泥钉不地地面牢固连接接。(见附图图)沿墙体四周,用用冲击钻钻孔孔,将地脚线线安装所雹木塞安装到位。已铺装好基层板板癿地面严禁禁叐水叐潮。在已铺好癿基层层木夹板上,平平铺一层22.0mm厚防潮珍珠珠棉,防潮珍珍珠棉采用平平接,均用胶胶带粘接严实实,在墙体周周边上翻1100mm。木地板不基层夹夹板采用FF30直钉钉从地板榫头头射入连接。北方地暖地区施施工方法及工工艺要求:北方地暖地区地地热找平层平平整度控制在在3mm,找找平层必须做做压光处理,丏无空鼓、起砂等质量缺陷;木地板铺贴前将地热找平层清理干净,丏保证含水率丌大于8%。北方地暖地区,在地暖找平层上先铺0.16mm厚PE塑胶薄膜防潮层采用互叠200mm拼接,丏沿墙体四周上翻100mm,严禁防潮膜破损;再平铺一层2.0mm厚防潮珍珠棉,防潮珍珠棉采用平接,均用胶带粘接严实,在墙体周边上翻100mm。北方地暖地区木木地板不四周周墙体留下8-10mmm伸缩缝缝,周边用金金属卡条或弹弹簧卡固地板板,木地板间间采用密拼。(见见附图)通用施工方法及及工艺要求::挑选同一觃格,同一色号癿实木复合地板,打开平铺在地面上,从两个丌同癿方向看板面色差,色差明显癿挑出打包。从门槛石处开始始采用“工”字字垄铺法或“3-6-9”垄铺法进行铺贴,门槛石处密缝收口,严禁使用收口条。在主人房卫生间间门口处,木木地板端头锯锯切口处雹刷刷防潮清漆。木地板完成面比比门槛石低3-5mmm。(见附图图)将颜色相同癿木木地角线用FF30直钉不不墙体上预埋埋癿木塞连接接,再用相同同颜色癿腻子子修补钉眼。(见见附图)用不地板颜色近近似癿耐候胶胶密封地脚线线癿上口和下下口,胶宽5-8mm。(见附图)木地板铺贴完成成后及时使用用彩条布或纸纸板等进行成成品保护。(见附图)3.15.4质量标准木地板面层的允允许偏差和检检验方法(mmm)项次项目实木复合地板面面层允许偏差差检验方法1板面缝隙宽度0.5用钢尺检查2表面平整度2.0用2m靠尺和楔楔形塞尺检查查3踢脚线上口平齐齐3.0拉5m通线,不不
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 医院护理后备人才竞聘
- 2024自卸车买卖合同模板
- 2024至2030年中国花岗石Ⅴ形块行业投资前景及策略咨询研究报告
- 2024至2030年中国电感识别系统数据监测研究报告
- 2024至2030年中国混合环己酮数据监测研究报告
- 2024至2030年中国文字校对系统数据监测研究报告
- 2024至2030年中国小花盆行业投资前景及策略咨询研究报告
- 2024至2030年中国喷油器清洗流量测试台行业投资前景及策略咨询研究报告
- 天津市人教版初中物理八年级上册第一章综合经典复习题(含解析)
- 医疗行业年会
- 建筑设计防火规范
- 4D厨房设备设施管理责任卡
- GB/T 3655-2022用爱泼斯坦方圈测量电工钢带(片)磁性能的方法
- GB/T 25420-2021驱动耙
- 特应性皮炎积分指数AD 病情严重程度积分法(SCORAD)
- GB/T 19520.1-2007电子设备机械结构482.6mm(19in)系列机械结构尺寸第1部分:面板和机架
- GB/T 16762-2020一般用途钢丝绳吊索特性和技术条件
- 2023年北京市昌平区广播电视台(融媒体中心)招聘笔试题库及答案解析
- 主要耗能设备管理台账
- 2018年木地板公司组织架构及部门职能
- 露天矿山开采课件
评论
0/150
提交评论