1、Commander SK Options for Commander SK Michael Nakulski September 2004 Product Management Copyright 2004 © Control Techniques 1 Commander SK INDEX Page 3 - Options for Commander SK Page 4 - LED Remote Mounting Keypad Page 5 - LCD Remote Mounting Keypad Page 6 - Parameter Memory Stick Page 7 - Fi

2、eldbus Option Modules Page 8 - Extended I/O Page 9 - Extended I/O with Real-time-clock Page 10 - Commissioning Software Page 11 - PLC Function Programming Software Page 12 - PLC Function Stick Page 13 - Connecting Cable for PC Page 14 - Additional EMC Filters Page 15 - Top NEMA 1 Cover Page 16 - Bot

3、tom Glanding Metal Cover Product Management Copyright 2004 © Control Techniques 2 Commander SK Options for Commander SK Commander SK has many option possibilities which compliment the standard features and functions making it the most flexible general purpose AC drive. All the options described

4、 on the following pages are supported by all three frame sizes of Commander SK. The exception is the SM range of option modules which is only supported by sizes B & C. Size C Size B Size A Size 200 to 240V +/-10% 380 to 480 V +/-10% A 0.25 to 0.75 kW - B 1.1 to 1.5 kW 0.37 to 1.5 kW C 2.2 kW 2.2

5、 to 4.0 kW Product Management Copyright 2004 © Control Techniques 3 Commander SK LED Remote Mounting Keypad Ordering Code: SK-Keypad Remote Description: Remote panel mounting LED keypad display to IP54 (NEMA12 with additional function key. Selectable function key with LED to indicate function s

6、elected. Hand-Off-Auto, Jog, Reverse, etc. Connects to the RS485 Modbus RTU port on the drive via a standard RJ45 connector Connecting cable (up to 30m Simple panel cut-out - 21mm hole Fixed keypad on drive remains active. Compatibility: Commander SK only all sizes Product Management Copyright 2004

7、© Control Techniques 4 Commander SK LCD Remote Mounting Keypad Ordering Code: SM-Keypad Plus Description: Remote panel mounting LCD multilingual text keypad display to IP54 (NEMA12 with the additional “Help” key. For remote panel mounting only Multi-lingual 3 lines of text (English, French, Spa

8、nish, German & Italian Help function key Connects to the RS485 Modbus RTU port on the drive via standard RJ45 connector Simple panel cut-out - 21mm hole Fixed keypad on drive remains active A PC software tool enables you to set up your own text lines. Exactly the same LCD keypad as used by Unidr

9、ive SP Compatibility: Commander SK all sizes Unidrive SP Commander SX (IP66 Product Management Copyright 2004 © Control Techniques 5 Commander SK Parameter Memory Stick Ordering Code: SmartStick Description: Upload drive parameters to the SmartStick for storage or for easy setup of identical dr

10、ives or for downloading to replacement drives. SmartStick - 1 parameter configures as: Read - program the drive with contents Program - Drive parameter set loaded onto SmartStick Boot - Loads parameters at power up (and can then be removed - Read only and cant be changed! Compatibility: Commander SK

11、 all sizes Product Management Copyright 2004 © Control Techniques 6 Commander SK Fieldbus Option Modules Ordering Code: SM-PROFIBUS DP SM-DeviceNet SM-CANopen SM-INTERBUS SM-Ethernet (end 2004 Description: The most popular industrial fieldbus protocols are available in the SM range of option mo

12、dules. One option slot in sizes B & C allows an SM fieldbus option and other specified SM option modules to be fitted. Use fieldbus firmware version 3.0 or higher for complete compatibility for the entire range of AC drives. ETHERNET (TCP/IP Compatibility: Commander SK sizes B & C Unidrive S

13、P Commander SX (IP66 Product Management Copyright 2004 © Control Techniques 7 Commander SK Extended I/O Ordering Code: SM-I/O Lite Description: Additional I/O option with the following connections: 0V ±10V bi-polar or 4-20mA Analogue input 0-10V or 4-20mA Analogue output +24V Digital input

14、 Digital input This "Encoder Speed Reference" input is not a Encoder B or Digital input true quadrature counter - therefore applications Encoder B which require accuracy when operating close to Encoder A zero speed will not be possible. Therefore, Encoder A generally this option cannot be

15、used for position 0V Encoder +5V Relay Relay Relay applications but is more suited to applications that require accurate speed holding and speed following. Compatibility: Commander SK sizes B & C Unidrive SP Product Management Copyright 2004 © Control Techniques 8 Commander SK Extended I/O

16、with Real-time-clock Ordering Code: SM-I/O Timer Description: Real-time-clock for scheduling drive running as well as the following additional I/O connections: 0V ±10V bi-polar or 4-20mA Analogue input 0-10V or 4-20mA Analogue output +24V Digital input This "Encoder Speed Reference" i

17、nput is not a Digital input true quadrature counter - therefore applications Encoder B or Digital input which require accuracy when operating close to Encoder B zero speed will not be possible. Therefore, Encoder A Encoder A generally this option cannot be used for position 0V applications but is mo

18、re suited to applications that Encoder +5V require accurate speed holding and speed Relay Relay Relay following. Size B Real Time Clock (Year, Month, Date, Week day, Hour, Minute, Second Size C Compatibility: Commander SK sizes B & C Unidrive SP Product Management Copyright 2004 © Control T

19、echniques 9 Commander SK Commissioning Software Ordering Code: CTSoft (comes free-of-charge with product CD ROM Description: Software for your PC or laptop which allows you to commission and store parameter settings. Use with CT Comms Cable. Drive Set up & Monitoring Software Tool this one softw

20、are package handles all key CT drive products Upload / download / store parameter setups Easy set up Wizards Compatibility: Commander SK all sizes Unidrive SP Product Management Copyright 2004 © Control Techniques 10 Commander SK PLC Function Programming Software Ordering Code: SyPTLite (comes

21、free-of-charge with product CD ROM Description: Software for your PC or laptop which allows you to program PLC functions within the Drive. Use with LogicStick and CT Comms Cable. SyPTLite: A ladder diagram editor allowing the development of application programs (30-50 rungs typical IEC 61131-3 envir

22、onment - same as leading PLC programmers Library of Standard Function Blocks Self Documenting Fully Compatible with Unidrive SP Compatibility: Commander SK all sizes Unidrive SP Product Management Copyright 2004 © Control Techniques 11 Commander SK PLC Function Stick Ordering Code: LogicStick D

23、escription: The LogicStick plugs into the front of the drive and enables you to program PLC functions within the drive. Use with SyPTLite software and the CT Comms Cable. Nano and micro PLCs can be easily replaced by LogicStick Memory storage for application or customer specific functionality Applic

24、ation Programming using SyPT Lite IEC61131-3 (Industry Standard Ladder Compatibility: Commander SK all sizes Product Management Copyright 2004 © Control Techniques 12 Commander SK Connecting Cable for PC Ordering Code: CT Comms Cable Description: Cable with isolated RS232 to RS485 converter. Fo

25、r connecting your PC / laptop to the drive when using CTSoft or SyPTLite. Use with SyPTLite PLC Function software or CTSoft commissioning software. SELV isolation rated for safety and reliability. Compatibility: Commander SK all sizes Unidrive SP Commander SX (IP66 Product Management Copyright 2004

26、© Control Techniques 13 Commander SK Additional EMC Filters Ordering Code: EMC Footprint Filters: Size A - 1 Phase EMC Filter Size B - 1 Phase EMC Filter Size B - 3 Phase EMC Filter Size C - 1 Phase EMC Filter Size C - 3 Phase EMC Filter Low Earth Leakage EMC Filters: Size A - 1 Phase Low Earth

27、 Leakage EMC Filter Size B - 1 Phase Low Earth Leakage EMC Filter Description: The EMC footprint filters are designed to operate together with the drives own internal EMC filter in areas of sensitive equipment. In areas where EMC filtering is required and earth leakage current interferes with the protection equipment (i.e. RCD circuit breakers the range of low earth leakage EMC filters can be used. The drives integral EMC filter must be disconnected when using the low earth leakage EMC filters. Compatibility: Commander SK all sizes Produc

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论