版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
房间风机盘管空调器安全要求(Safetyrequirementsforroomfancoilunits)RoomfancoilairconditioningsafetyrequirementsJB9063-1999Bureauofnationalmachineryindustry1999-05-14-07-01theimplementationofapproved1999PrefaceThisstandardisarevisionoftheZBJ72018-88"theroomfancoilairconditioningsafetyrequirements".ThisstandardandZBJ72018-88comparedtomaincontentchangeasfollows:Standardnamewaschangedto"theroomfancoilairconditionersafetyrequirements";Cancel:mechanicalstrengthsection.ThisstandardfromthedateofimplementationofZBinsteadofJ72018-88.ThisstandardbythenationalRefrigerationEquipmentStandardizationTechnicalCommitteeandfocalpoints.ThisstandardwasdraftedbytheShanghaiTonghuiCarrierairconditioningequipmentCo.ltd..Themaindraftersofthisstandard:YangWeirong.Therangeof1Thisstandardspecifiestheroomfancoilairconditioner(hereinafterreferredtoastheunit)thesafetyrequirementsanddeterminationmethod.Thisstandardisapplicabletogeneralconditions,withthecold(hot)waterascold(hot)media,tocreateacomfortableindoorenvironmentforthepurposeoftheunit.Thisstandardisnotsuitableforuseundertheconditionofcorrosiveandexplosiveandtheship'screw.2referencestandardThefollowingstandardscontainprovisionswhich,throughreferenceinthistext,constituteprovisionsofthisstandard.Atthetimeofpublication,theeditionsareeffective.Allstandardswillberevised,thepartiesusingthisstandardshoulddiscussthepossibilityofusingthelatestversionofthefollowingstandards.GB4706.1-1992safetyofhouseholdandsimilarelectricalappliancesgeneralJB/T4283-1991fancoilunitDeterminationof3Safetyrequirementsand/ormeasures3.1GeneralrequirementsUndernormalconditionsofuseshallensurethesafeandreliableoperationoftheunit,evenifthewrongoperationdoesnotgivepeopleandthesurroundingenvironmentcausedbydanger,todealwithallthetestitemstest.Testitemsspecifiedinthisstandardaretypeofpilotprojects.3.2protectionagainstelectricshockThestructureandtheshellunitshouldhavegoodprotectionagainstelectricshock,toensurethattheuserisnotaccidentalcontactwithliveparts,evenwithouttoolscandisassemblepartsshouldalsobethecase.Inthenormalinstallationcondition,inspectionaccordingtotheprovisionsinthe8.1GB4706.1-1992.Theterminalwiththeclosedshell,andshouldhelptoremovethetool.Normaluseofknobsorswitchesintheshaftorrodshouldnotbecharged.Thewiremustbeusedtoprotectthecoat.Connectthepowerplugoftheunit,shouldensurethatundernormalusewillnottouchthepinsbecausethecapacitordischargecausedbytheriskofelectricshockinthedesign,inspectionaccordingtotheprovisionsinthe8.9GB4706.1-1992.3.3startThefuseshouldbespecifiedusingproductdesignmodelsandtheratedcurrentofthestartingtest,overloadprotectiondeviceoperatingmanualresetshouldnotbeintheprocessoftest.In85%oftheratedvoltage,thestart-upoftheunit3times,eachtimeyoustartthemotorshouldbecarriedoutinfullstopafter;Ifthereareseveraladjustablespeed,youshoulddotheabovetestineverygearspeed.Inthiscase,thefancoilshouldbeabletoworksafelyandreliably.Three4feverThe3.4.1unitshouldbeinstalledinthelaboratoryaccordingtothemanufacturerrequirements,measuredatthemaximumheatingandcoolingconditions.The3.4.2unitshouldworkinanyvoltagebetween1.06timesto0.94timesthelowestratedvoltageandratedvoltage,themaximumheating.3.4.3testunitsshouldbeintheintakeairtemperatureis23DEGC-2DEGC,thewatertemperatureisthehighestunitinlettemperatureis80DEGCundertheconditionofcontinuousworkuntilthetemperaturereachesstable.ThetestmethodandthemaximumallowabletemperatureriseshouldcomplywiththerelevantprovisionsofGB4706.1-1992intheEleventhchapter.3.5attheoperatingtemperatureoftheleakagecurrentTheunitshouldhavegoodelectricalproperties,leakagecurrentvalueshouldnotexceed1.5mA,thecorrespondingtestmethodinaccordancewiththeprovisionsofGB4706.1-1992inthethirteenthchapter.3.6insulationresistanceandelectricstrengthTheunitshouldhavegoodinsulatingproperties,anddeterminedbythefollowingtests:A)measuringinsulationresistanceinDC500V1min,inbetweenlivepartsandshellanditsvaluenotlessthan2M.B)electricstrengthtestfor1min,ACvoltagewithstandfrequencyasbasicsinewave50Hz,thetestvoltageandtestpartsasspecifiedinTable1.Thefirstapplicationofvoltageshouldnotexceedhalfthespecifiedvalue,andthenquicklyrisetothespecifiedvalue,flashoverandbreakdownduringthetestshouldnot.Table1PartofthetestvoltageisappliedtestvoltageVBetweenlivepartsandallaccessiblemetalparts;Insulatingmaterialsforliningmetalshellandametalcoverandametalfoilcladonthesurfaceoflininginbetween(ifbetweenlivepartsandthemetalshellandthemetalcoverdistanceislessthanGB4706.1-1992inthe29.1properclearancerequired);Betweenlivepartsofdifferentpolarity;Betweenthemetalpartscanbetouchedandwrappedinmetalfoilorpowerlineandthepowerlinebetweenthemetalrodsofthesamediameter(themetalrodhangingonthepowerlineposition,fixedinthepopulationofinsulationmaterials,wirecasingsheath,powerlinefixingdeviceandsoon)1250Themetalfoilincontactwiththeknob,switchandshaftorrod(incaseoffailureofinsulationbetweentheaxisofcharged)25003.7moistureTheelectricalcomponentsoftheunitshouldbetopreventtheintrusionofwater(dew).Theunitshouldmakethecondensedwaterdrainage,drainageshouldnotaffectthenormalunitofelectricalinsulation.3.8nonnormalworkThedesignof3.8.1unitshouldbeavoidedduetoabnormalandmisuseofthefire,mechanicalinjuryorelectricshock.3.8.2fanmotorshouldbelockedrotortest.Themotorrotorshaft,withratedvoltageofelectricityfor15days(360h),oruntilthepermanentopencircuitprotectiondevicesofar.Thepolarityofthepowersupplyshouldbereversingonceevery24h.Testtheambienttemperatureat23DEGC+C5,ifthetemperatureofthemotorwindingwhenthesteadystateoperationdoesnotexceed90degrees,youcansuspendthetest.Otherwiseitshouldbemeasuredislessthan150DEGCshelltemperatureduringthewholeexperiment,andthetemperatureofthewindingsshallnotexceedtheprovisionsofTable2andtable3.Table2CThetypeofprotectionshell(sealed)150Nothavinga150windingprotectiondeviceE165B175F190H210WiththeLHwindingprotectiondevice200Attheendoftheexperiment175Duringthetesttheaveragevalueof150Table3CTypeofprotection(motor)insulationmaterialclassificationandtemperaturelimitsAElevelBlevelFlevelHImpedanceprotectionTheprotectiondeviceinfirstduringHtoprotectitsmaximumvalueToprotecttheprotectiondeviceinfirsthafteroperation,themaximumvalueToprotecttheprotectiondeviceinfirsthafteroperation,themeanvalueof150TwohundredOnehundredandseventy-five150165TwohundredandfifteenOnehundredandninety165175Twohundredandtwenty-fiveTwohundred175190TwohundredandfortyTwohundredandfifteen190210TwohundredandsixtyTwohundredandthirty-fiveTwohundredandten3.9mechanicalsafetyprotectionTheactivitycomponentsapplicationunithousingprotection,toensurethesafetyofthepeople.Protectivecasingandsheathshouldhavesufficientmechanicalstrengthandonlybymeansoftoolstodisassemble.3.10structure3.10.1ensurethatallpartsofwaterproofandantishockrequirementsonlywithtoolstoremove.3.10.2inthedesignoftheunitstructure,shouldbeconsideredduetocondensationofwater(DEW),fromthepipeconnectorandthevalveattheleakingwaterofelectricalinsulation.Directcontactwith3.10.3corrosionresistance,waterabsorption,flammabilityandinsulationmaterialcannotbareliveparts.3.11internalwiring3.11.1troughshouldbesmooth,notsharp.Thewireshouldbeprotected,noburr,contactheatexchangeraluminumsheet,soastoavoiddamagetothewiringinsulation.Throughthemetalholesurfaceofinsulatedconductorsshallbesmooth,andtheinsulatingsleeve.Byinspectiontodeterminewhetherornotqualified.3.11.2internalwiringmustbefixed,thecreepagedistanceandclearanceconformtotherelevantprovisionsofGB4706.1-1992inthetwenty-ninthchapter.3.11.3shallnotbeusedasaluminumwireinternalwiring.Green/yellowwire3.11.4,receivedonlythegroundterminalcannotconnecttotheotherterminal.The3.12elementAllthecomponentsusedin3.12.1unitsshouldmeetthesafetyrequirementsofthecomponentsofthecorrespondingstandards,andasapartoftheinspectionunittowithstandthisstandard.Capacitor3.12.2onmotorwindingpermanentseries,shouldchecktheunitin110%oftheratedvoltageandtheminimumloadoperationwhentheterminalvoltageofthecapacitor,thecapacitorvalueshouldnotexceedtheratedvoltageof110%.3.12.3unitshouldnotbeequippedwith:A)connectedtotheswitchinthecord;B)iftheunitfails,thedevicepowersupplyinterruptionbyshortcircuit.3.13groundingdevice3.13.1earthingdeviceshallcomplywiththerelevantprovisionsofGB4706.1-1992inthetwenty-seventhchapter.3.13.2intheoperationoftheunitduringthepersonnelcontactmayberelatedtotheuseofnoninsulatedmetalpartsfullyconnectedwiththeearthingdevice.3.13.3throughthetesttodeterminewhetheritmeetstherequirementsofgroundingdevice:Withno-loadvoltagenotexceeding12VACpowersupply,the25Acurrentinturnbetweengroundingterminalsorgroundingandallaccessiblemetalpartsthrough.Voltagemeasurementofgroundingterminalsorbetweenthegroundcontactandaccessiblemetalpartsdrop,Accordingtothecurrentandvoltagedropcalculatedresistancevalue.Thevalueshouldnotexceed0.1Ntheresistanceunderanycircumstances.3.14heatinsulation,soundinsulationmaterialThe3.14.1unitusedforheatins
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 湖北第二师范学院《体育管理学》2022-2023学年第一学期期末试卷
- 2024百香果买卖合同书
- 2024简易工程机械租赁合同范本
- 2024天猫旗舰店转让合作合同(律师拟定版本)
- 湖北大学知行学院《食品包装学》2023-2024学年第一学期期末试卷
- 2024股权抵押借款合同模板
- 《多元相关与回归》课件
- 2024小额贷款公司抵押合同范本
- 2024成套设备进口合同书模板(合同版本)
- 李一环连锁总部门店标准化建立:店长标准化复制与督导标准化手册
- 物流专业个人能力展示
- 五年级上册小数除法竖式计算练习300题及答案
- 大学生职业规划数据分析师
- 技改方案范文
- 县人民医院关于职工工资与绩效等待遇的规定
- 农村自建房施工安全措施方案
- 护理产业与行业分析
- 征地拆迁安置区市政配套设施工程测绘服务公开选取测绘招投标书范本
- 《我的祖国》课件
- 小学一年级上学期思维训练数学试题(答案)
- 听风八百遍才知是人间
评论
0/150
提交评论