版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
/
ConstructionSchemeofReflectiveThermalInsulationCoatingforExteriorWallofThreeResidentialBuildings,TwoCommercialBuildingsandOneUndergroundGarageinSFGarden
catalogue
ChapterIProjectOverview1
ChapterIIiscompiledonthebasisof4
ChapterIVConstructionandDeploymentof5
ChapterVConstructionTechnologyofCeramicTileFacingReflectiveThermalInsulationCoating6
ChapterVIConstructionProgressPlan9
ChapterVIIResourceDemandPlan10
ChapterVIIIConstructionPreparationWorkPlan11
ChapterIXConstructionMeasuresPlan15
ChapterXSafetyGuaranteeMeasures19
Chapter11ConstructionCoordinationMeasures22
ChapterXIIMeasurestoEliminateCommonQualityFaults23
ChapterXIIIWarrantyMeasures24
ConstructionSchemeofReflectiveThermalInsulationCoatingforExteriorWallofThreeResidentialBuildings,TwoCommercialBuildingsandOneUndergroundGarageinSFGarden
ChapterIOverviewoftheProject
I.Generalsituationofbuildings
Engineeringdescription
Projectnamesof3residentialbuildings(self-numberedG-12,J-13,J-14)and2commercialbuildingsinSFGarden
Building(numberedGJ-4,GJ-5)and1basementproject
Constructionsite:ShiFengRoad,ShijingTown,BaiyunDistrict,XXCity
ConstructionunitXXCityJifengRealEstateDevelopmentXX
SupervisionunitXXYunxingconstructionprojectsupervisionXX
InvestigationunitXXCityUrbanPlanningSurveyandDesignInstitute
DesignunitXXXXBaiyunBuildingXXXX
ConstructionunitXXSouthConstructionGroupXX
3residentialbuildingsinSFGarden(self-numberedG-12(F-12),J-13(F-13),J-14(F-14)),commercial
Twobuildings(numberedGJ-4andGJ-5)andonebasementprojectarelocatedinShiFengRoad,ShijingTown,BaiyunDistrict,XXCity.
Itconsistsofanundergroundparkinggarage,twocommercialbuildingsandthreehigh-riseresidentialbuildings,withanareaof16,473㎡forconstructionbystages,withatotal
Thebuildingareais43,386㎡,ofwhichtheundergroundbuildingareais99,001㎡andtheabove-groundbuildingareais33,485.9㎡.
1floorunderground,15floorsaboveground,thebuildingcorniceelevationis47.1m,thebuildingcategoryisClassI,andthebuildingfireresistanceratingis
ClassI,thecivilairdefenseengineeringgradeisClass5,thestructuretypeisframeshearwallstructure,theseismicfortificationintensityis7degrees,andthedesignstandard.
Theheightof0.000isequivalenttotheabsoluteelevationof8.450,andthedesignedservicelifeis50years.
II.Generalsituationofstructure
ThedesigngradeofthefoundationofthisprojectisGradeA,thefoundationisCMcompositefoundation,thefoundationispileraft,andthestructuretypeisframeshear.
Thewallstructurehasaseismicfortificationintensityof7degrees,andthesafetylevelofthebuildingstructureisGradeII.
III.Overviewofwallenergy-savingdesign
Theinnerandouterwallsofthisprojecttoweraremadeofconcreteaeratedblocks,thethicknessoftheouterwallsis200mm,andthethicknessoftheinnerpartitionwallis100mm.
200MM,and150mmthickaeratedblockisusedforthepartitionwallofstairwell.Amongthem,theexteriorwallofthetowerisdecoratedasfollows:
1,brickexteriorwallpractice
1)whiteexteriorwallthermalinsulationreflectivecoating;
XXX1ofJuntaiConstructionProject
ConstructionSchemeofReflectiveThermalInsulationCoatingforExteriorWallofThreeResidentialBuildings,TwoCommercialBuildingsandOneUndergroundGarageinSFGarden
2)Externalwalltiles,gluedwithadhesive;
3)5thickanti-crackingmortarcompositehot-dipgalvanizedsteelwiremesh(wirediameter0.9mm),aperture12.7*12.7mm),plasticanchor
Two-wayboltspacing500mmanchorage;
4)brushtheinterfaceagenttogether;
5)5mmthickpolymerwaterproofmortar;
6)10mmthick1:3cementmortarlevelinglayer;
7)Treatingtheinterfaceofthewallsurfaceatthegrass-rootslevel,brushingtheinterfacemortartogether;
2.Thermaldesignparametersofbuildingenergy-savingmaterialsinthisprojectareasfollows:
Averagesolarradiationabsorptioncoefficientofexteriorwall:ρ≤0.75,averageheattransfercoefficientofexteriorwallKm:
1.48W/(㎡k)AveragethermalinertiaindexDM:3.19.
IV.Overviewofreflectivethermalinsulationcoatingsforexteriorwalls
Reflectivethermalinsulationcoatingforexteriorwallistoreflect(radiate)theheatgeneratedbyinfraredraysinthesunlight,thusachievingthermalinsulation,
Afunctionalcoatingforthermalinsulation.Thecoatingiscomposedoffilm-formingmaterials,pigmentsandfillers,specialfunctionalmaterialsandadditives.every
Allkindsofmaterialshavedifferentinfraredabsorptionandreflectivity,soweshouldpayattentiontotheperformanceofeachmaterialwhenselectingmaterials.
1.Film-formingmaterials(resins):Mostorganicresinsasfilm-formingmaterialsaretransparentinthenear-redregion,
Whilevisiblelightabsorbssomeenergywiththedifferentcolorofresin.Generally,colorlesstransparentresinhardlyabsorbs.
Theenergyofsunlight.Therefore,resinscommonlyusedingeneralcoatingscanbeusedforsolarphotothermalreflectivecoatings.
XX2ofJuntaiConstructionProject
ConstructionSchemeofReflectiveThermalInsulationCoatingforExteriorWallofThreeResidentialBuildings,TwoCommercialBuildingsandOneUndergroundGarageinSFGarden
Theresinusedforexteriorwallreflectivethermalinsulationcoatingrequiresthatthelowertheabsorptionrateofvisiblelightandnearinfraredlight,thebetter.Most
Resincanmeet;Thehigherthetransparencyofresinisrequired,thelowerthesolarabsorptionrateis.Solarheatabsorptionofseveralcoatings
Theyieldisshowninthetable:
Solarthermalabsorptivityofseveralcoatings
Coatingpigmentabsorptionrate
OrganicresinTiO20.10epoxyresinTiO20.25
Silicone-acrylicresinTiO20.19polyurethaneresinTiO20.26
Silicone-alkydresinTiO20.22acrylicresinTiO20.24
2.Pigmentsandfillers:Exteriorwallreflectivethermalinsulationcoatingachievesthepurposeofthermalinsulationandcoolingbyreflectinginfraredraysinsunlight.
Yes,pigmentsandfillers,likeresins,requirethatthegreaterthereflectivityofvisiblelightandnearinfraredrays,thebetter,andthesmallertheabsorptivity,thebetter.
Atthesametime,inordertoreducethetransmissionofsunlight,pigmentsandfillersshouldalsohavethegreatestscatteringeffectonsunlight.
Factorsaffectingsunlightscatteringbypigmentsandfillers;
①CoveringpowerofpigmentsandfillersThegreaterthecoveringpowerofpigmentsandfillers,thegreaterthescatteringeffectonsunlight.Pigmentfiller
Titaniumdioxide(rutiletype)hasthelargesthidingpower,anditalsohasagreatscatteringeffectonsunlight.
②Refractiveindexofpigmentsandfillers.Therefractiveindicesofvariouspigmentsandfillersarealldifferent,andthedifferencesareveryhighandlow,asshowninTable3.
Refractiveindexofpigmentsandfillers
Namerefractiveindexnamerefractiveindex
Titaniumdioxide(rutiletype)2.80bariumsulfate1.64
Titaniumdioxide(anatase)2.50magnesiumsulfate1.58
2.2zincoxideand1.54silicondioxide
Lithopone1.84ironoxidered2.80
Talcpowder1.59ironoxideyellow2.30
Alumina1.7
3.Specialfunctionalityofpigmentsandfillers:Specialfunctionalitymeansthatitcanplayahigherroleinexteriorwallreflectivethermalinsulationcoatingsatthesametime.
Synergisticpropertiesofanti-radiationanddiffusescattering,suchasnano-titaniumdioxide,antimonytrioxide,oxidation
Zirconiumandsomeothernanomaterials,phasechangematerials(vanadiumdioxideanditsdopants)andhollowglass(ceramic)microbeads.
Wait.
XXX3ofJuntaiConstructionProject
ConstructionSchemeofReflectiveThermalInsulationCoatingforExteriorWallofThreeResidentialBuildings,TwoCommercialBuildingsandOneUndergroundGarageinSFGarden
Hollowglass(ceramic)microbeadsaregenerallyaddedtotheintermediatecoating.Afterthecoatingiscuredtoformafilm,afilmisformedinthecoating
Thebarrierofhollowsphericalglassbeadsblockstheintroductionofheat.
4.Additives
Itsadditivesaresimilartopigmentsandfillersofgeneralcoatings:
(1)becausetheexteriorwallreflectivethermalinsulationcoatingshouldhavethespecialfunctionofthermalinsulation,somanufacturersmakeitwhite,which
Samplescankeepgoodreflection,whichisconducivetotheheatinsulationfunction.Onthecontrary,nomatterwhatcolor,theheatinsulationeffectwillbereduced.
②Thethermalinsulationperformanceofexteriorwallreflectivethermalinsulationcoatingisalsocloselyrelatedtothesurfacecleanlinessofthecoating.Addspecial
AdurablesurfactantisusedtoadjustthesurfaceXforce,sothatthecoatingishydrophilic,antifoulinganddurable.Whenbeingwashedbyrain,
Thedustonthesurfaceofthecoatingiswashedawaybyrain,leavingnoraindropimprintafterdrying,andkeepingtheappearanceofthecoatingwithoutanyinfluence.
Clean.
ChapterIICompilationBasis
1.UnifiedStandardforAcceptanceofConstructionQualityofBuildingEngineering(GB50300-2013)
2.CodeforQualityAcceptanceofBuildingDecorationEngineeringX(X》(GB50210-2018)
3.CodeforAcceptanceofConstructionQualityofBuildingEnergy-savingProjectsX(SZJG31—2014)
4.Energy-savingTestingStandardforArchitecturalReflectiveThermalInsulationCoatings(JGJ/T287-2014)
5,theXXprovincebuildingenergy-savingengineeringconstructionqualityacceptancespecificationX(DBJ15-65-2009)
6.TechnicalSpecificationforApplicationofReflectiveThermalInsulationCoatingsforBuildingsinXXProvince(DBJ15-75-2010);
7.ReflectiveThermalInsulationCoatingsforBuildings(JG/T235-2014);
8.ReflectiveThermalInsulationCoatingsforBuildings(GBT25261-2010););
XXX4ofJuntaiConstructionProject
ConstructionSchemeofReflectiveThermalInsulationCoatingforExteriorWallofThreeResidentialBuildings,TwoCommercialBuildingsandOneUndergroundGarageinSFGarden
9.TechnicalSpecificationforApplicationofReflectiveThermalInsulationCoatingsforBuildings(JGJ/T359-2015)
10.CodeforAcceptanceofConstructionQualityofResidentialBuildingEnergy-savingProject(DB11/1340-2016)
11,thebuildingconstructionsafetyinspectionstandard(JGJ59-2011)
12.TechnicalSpecificationforSafetyofAerialWorkinConstructionX(JGJ80-2016)
13.HangingBasketforAerialWork(GB19155-2003)
14,theconstructionsitetemporaryelectricitysafetytechnicalregulationsx(jgj46-2012)
15.thearchitecturalandstructuraldesigndrawingsofXXxxBaiyunbuildinginxxcityprovidedbytheowner,thearchitecturalfestival
DesignSpecialArticles"andrelatedreviewopinions;
ChapterIVConstructionDeployment
I.Organization
Second,thequalityobjectives
AccordingtotheengineeringstandardofXXprovince,codeforacceptanceofconstructionqualityofbuildingenergy-savingengineeringinXXprovince,dbj15-65-2009,
Theengineeringqualityofreflectivethermalinsulationcoatingforexteriorwallhasreachedthequalifiedstandard.
III.Energy-savingtargets
StrictlyimplementtheprovisionsoftheCodeforAcceptanceofConstructionQualityofBuildingEnergy-savingProjectsX(SZJG31-2010)toensurethisproject
XXX5ofJuntaiConstructionProject
ConstructionSchemeofReflectiveThermalInsulationCoatingforExteriorWallofThreeResidentialBuildings,TwoCommercialBuildingsandOneUndergroundGarageinSFGarden
Meettheenergy-savingstandardsrequiredbydesignandregulationX..
IV.Constructionpreparationwork
1,shouldbeengagedinbuildingenergy-savingengineeringconstructionrelatedemployeesforbuildingenergy-savingstandardsandtechnologiesandotherprofessionalknowledge.
Knowledgetraining.Constructionmanagersshouldparticipateincontinuingeducationofbuildingenergyconservationpractice.
2,theconstructionsite,shouldbeequippedwiththerelevantnationalandmunicipallawsandregulationsonbuildingenergyconservationandtheproject-relatedbuildingenergyconservation.
Sexstandard.
3.Beforetheconstructionofbuildingenergy-savingproject,theprojectchiefengineershouldorganizetheconstructionpersonneltobefamiliarwiththedesigndocumentsandparticipateinthejointreviewofconstructiondrawings.
Anddesigndisclosure.
4,thejointreviewofconstructiondrawings,shouldreviewwhetherthebuildingenergy-savingdesigndrawingshavepassedtheexaminationoftheconstructiondrawingdesignreviewunit.
Constructiondrawingsthathavenotbeenexaminedorreviewedanddonotmeetthemandatorybuildingenergyefficiencystandardsshallnotbeused.
5.Disclosureofbuildingenergy-savingdesign.
V.Workintheconstructionphase
Beforeconstruction,theapplicationformofmaterials/components/equipmentofbuildingenergy-savingengineeringtobebroughtintoplayshallbesubmittedasrequired(includingwall
Materials,thermalinsulationmaterials,doorandwindowparts,lightingequipment,etc.)andtheirqualitycertificationmaterials,asfollows:
1)Qualitycertificationmaterials(warrantyletter,specification,typeinspectionreportandreinspectionreportofinsulationsystemandcomponentmaterials)
Whetheritisqualifiedandcomplete,andwhetheritmeetstherequirementsofdesignandproductstandards.Asindicatedintheproductspecificationandproductidentification.
Whethertheperformanceindexmeetsthebuildingenergyefficiencystandard.
2)Whethertousematerials,componentsandequipmentthatarebannedoreliminatedbythestate.
3)Whetherthereisarecordcertificateofbuildingmaterialsandcorrespondingverificationrequirements.
4)Follow-upinspectionorwitnesstakingaccordingtotheproportionoftheentrustedconstructioncontractandtherelevantprovisionsofbuildingenergyefficiencystandards.
Sample,sendsamplesfortesting.
5)Thebuildingenergy-savingengineeringmaterials,componentsandequipmentthathavenotbeenacceptedorfailedtobeacceptedshallnotbeusedinengineering.
Orinstall;Thematerials,componentsandequipmentthatarebannedoreliminatedbythestateshallnotbesignedandrecognized,andtheywillfailtopassthedeadline.
Buildingenergy-savingengineeringmaterials,componentsandequipmentshallbewithdrawnfromthesite.
6)Patrolandinspectthebuildingenergy-savingconstructionprocess.Theunqualifiedprocessshallnotbefollowedbythenextprocess.
Construction.
ChapterVConstructionTechnologyofCeramicTileFacingReflectiveHeatInsulationCoating
XXX6ofJuntaiConstructionProject
ConstructionSchemeofReflectiveThermalInsulationCoatingforExteriorWallofThreeResidentialBuildings,TwoCommercialBuildingsandOneUndergroundGarageinSFGarden
I.Basictechnologicalprocess
Thefollowingconstructiontechnologyisadoptedforcoatingceramictilereflectivethermalinsulationcoating:
Treatmentandcleaningofouterwalltilebaselayer→sprayingsealingprimerfor1time→sprayingreflectivethermalinsulationcoatingprimerfor1time→spraying.
Applyintermediatepaintofreflectivethermalinsulationcoatingonce→sprayfinishpaintofreflectivethermalinsulationcoatingonce→sprayfinishpaintonce→details.
Management→cleaningandmaintenance.
Second,themainmaterialselection
1.Cleaningmaterials:dilutehydrochloricacidoroxalicacidornaturalwater,etc.
2.Sealingprimer:"YingsuGranule"brandisadopted.Thisprimerhasgoodpermeability,excellentalkalisealingresistanceofpaintfilm,andgoodalkaliresistance.
Stronglayeradhesion;
3.Sprayreflectivethermalinsulationprimer:adoptthebrandof"YingsuGranule",andsprayreflectivethermalinsulationprimertoimprovethebase.
Adhesionoflayer;
4.Sprayreflectiveheat-insulatingintermediatepaintandfinishpaint:adopt"YingsuGranule"brand,reflectiveheat-insulatingpaintandmaincoating.
Remarkableradiationheatinsulationeffect,excellentwashingresistance,stainresistance,weatherresistance,algaeresistanceandmildewresistance,andgoodvisualeffect;
5.Overcoat:Itadopts"YingsuGranule"brand,whichhashighglossandglossretention,andplaysadecorativeandprotectiverole.
III.ConstructionTechnologyandRequirements
1,grassrootsrequirements
(1)Afterthecompletedexteriorwalltilesarequalified,theywillbehandedovertotheexteriorwallreflectivethermalinsulationcoatingprofessionalconstruction.
Unitconstruction.
(2)Thesurfacetreatmentoftheexternalwalltilesmustbesmoothandconsistentincolor,andthetilesshouldnotbepeeled,powdered,orchipped.
Andotherphenomena;Thesurfaceofbrickmortarjointshallbesmooth,withoutlooseness,sanding,pulverization,cracks,damages,honeycombsandholes.
Andhassufficientstrengthandrigidity.
(3)Theprofessionalconstructionunitofexteriorwallreflectivethermalinsulationcoatingusesdilutehydrochloricacidoroxalicacidornaturalwaterfortheconstructionface.
Suchascleaningmaterialsforcomprehensivecleaning.Accordingtothetop-downeverythreelayerstocleanagain,cycle,verticalconstructionface.
Staggeredwitheachothertopreventandavoidsecondarypollutioncausedbytoolongcleaningintervalandconstructionprocess.
(4)Themoisturecontentofthebaseshouldbe<8%,andthePHvalueshouldbebelow10.Iftheaboverequirementsarenotmet,theconstructionperiodshouldbeappropriatelyextended.
2.Constructionofsealingprimer
(1)onthebasethatmeetstheconstructionconditions,paintbrushshallbeusedtobrushtheinternalcornersfirst,andthentheexteriorwallbeddingfaceshallbesprayed.Requirements
Nosagging,nobrushleakage,thedosageis0.17~0.20㎏/㎡(once),anditcanbedilutedaccordingtotheneed,butthewaterisadded.
XXX7ofJuntaiConstructionProject
ConstructionSchemeofReflectiveThermalInsulationCoatingforExteriorWallofThreeResidentialBuildings,TwoCommercialBuildingsandOneUndergroundGarageinSFGarden
Nomorethan15%.Afterpriming,thesurfaceshouldbeuniformincolor,andtherearenoproblemssuchascoatingleakageandprimerpenetration.
(2)Afterthebasecoatiscompletelydry(about24h),thereflectiveheatinsulationcoatingforexteriorwallshallbeconstructed.
3.Constructionofreflectivethermalinsulationcoating
(1)sprayingreflectiveheat-insulatingpaintprimer,reflectiveheat-insulatingpaintintermediatepaintandreflectiveheat-insulatingpainttopcoat
Construction,shouldbefromtoptobottomaccordingtoeverythreelayersofaconstructionperiod,afterthecompletionofeachlayerofpaintconstruction,eachtimefinishingmaterials.
Materialconstructionmustbecarriedoutafterthesurfaceofthepreviouscoatingmaterialisdried(about4hours),andeachcoatingmaterialshouldbecoated.
Uniformdecoration,eachlayeroffinishingmaterialsmustbecombinedfirmly,andthenumberoftopcoatingscanbeincreasedforprojectswithspecialrequirements;
A,ingredients:Lipudowithhigh-efficiencyhemisphericalreflectionabilityismixedwithfinishaccordingtotheratioof1:12.
Sprayevenlyonthetilesurfaceoftheexteriorwallwithaspraygun,withthedosageof0.20~0.25㎏/㎡(once),andthesprayingtimesarehorizontal,
Sprayitverticallyandvertically.
B.Sprayingconstruction:thedistancebetweenthemuzzleandthewallisabout25cm,andthehand-heldspraygunisusedtosprayevenlyhorizontally,verticallyandvertically.
Sprayonceineachdirection.Sprayisnotallowedinstrongwind(windspeedismorethan5m/min)andrainydays.
C.Coatingthicknessrequirements:thethicknessofeachcoatingisbetween0.18mm-0.23mm,andthesurfaceisuniform.
(2)Ontheclosedprimerlayerthatmeetstheconstructionconditions,selectapaintbrushtobrushtheinternalcornersfirst,andthenspraytheexteriorwallbeddingface.
Itisrequiredthatthereshouldbenosaggingandbrushleakage,andthesurfaceafterprimingshouldbeuniform,freefromcoatingleakage,virtualshadow,needleholesandairholes.
Question.
(3)Duringthewholeconstructionprocess,theconstructionviscosityoffinishingmaterialsshouldbebasedonthemethod,temperatureandhumidityintheconstructionseason,etc.
Theconditionsarestrictlycontrolled,andaspecialpersonshallberesponsiblefortheallocationaccordingtotheinstructions.Diluentorwatershallnotbeaddedatwill;
(4)Thecoatingmaterialsofthesamebatchnumbershallbeappliedtothesamewallsurfaceinthesamecolor.Whenthebatchnumberofthesamecolorisdifferent,thecoatingmaterialsshallbepreparedinadvance.
Evenlymix,toensurethatthesamewalldoesnotproducecolordifference;
(5)Whencoatingbyspraying,thecoatingfilmshouldnotbetoothickortoothin,anditshouldbefullycoveredandnottransparent.
Shadow,uniformsurface.
(6)Whenspraying,theviscosityofthecoatingandthepressureofthespraygunshouldbecontrolled,andthethicknessofthecoatingshouldbeuniform,withnoexposureandnoflow.
Drop,uniformcolor;
(7)Inthefastdryingseason,whenfinishinginalargearea,manypeopleshouldcooperatewiththeoperation,flowoperation,andapplyinthesamedirection.
Decoration,shoulddealwithsummer-plantingparts.
(8)Exteriorwallfinishingconstructionshouldbecarriedoutfromtoptobottom;Materialcoatingconstructionsectionshouldbeinmetopeframeseam,
YinandYangcornerofwallordownspoutisthedividingline.
XXX8ofJuntaiConstructionProject
ConstructionSchemeofReflectiveThermalInsulationCoatingforExteriorWallofThreeResidentialBuildings,TwoCommercialBuildingsandOneUndergroundGarageinSFGarden
4.Constructionoffinishcoat
Aftertheconstructionofreflectivethermalinsulationcoatingforexteriorwalliscompleted,finishcoatshallbeconstructed.Finishcoatmustbeusedbefore.
Mixwell,selectthemostsuitableconstructionratioandadjusttheappropriateadhesiveaccordingtothetemperature,humidityanddifferentcoatingmethodsonthespot.
Water-basedfinishpaintisakindofwater-basedpaint,soorganicsolventpollutionshouldbeavoided.
5.Detailtreatment
Mainlyfortheconstructionelevator,towercraneembeddedparts,balconylines,rainwaterpipesandotherpartsforsecondarytreatment.
6.Cleaningandmaintenance
Afterthecompletionofthedetailtreatment,clearupthewindowframe,glassandbalcony,whicharemainlycausedbytheconstruction.
Andair-conditioningrailings;Afterthecompletionofcleaning,conductacomprehensiveinspection,andcarryoutre-inspectiononthepartswheretheconstructionisnotinplace.
Secondarytreatment.
IV.ConstructionMeasures
1,ceramictilefacingexteriorwallreflectivethermalinsulationcoatingadoptsautomaticelectrichangingbasketforconstruction,electrichangingbaskettype.
No.ZLP630,whichisarrangedalongtheperipheryoftheexternalwall.First,theeast-westfacadeisconstructed,andthenthenorth-southfacadeisconstructed.
Thenumberis20,whichhasmettheconstructionneeds.
2.Theinstalleddoorsandwindows,decorativelayers,etc.arecoatedwithreflectivethermalinsulationcoatingforceramictilefacingexteriorwallwithwoodenboards,
Plasticplate,etc.Flowersandtreesinthegardenshouldbecoveredwithstripedclothbeforespraying.Hangingbasketdownto
Whentherearetreesandflowersplanted,stayabovethem.Peopleusethedoorframetogoupanddown,andthehangingbasketfallsonthetreesandflowers.
Outsidethegrassclearing;
V.PrecautionsforConstruction
1,payattentiontothesafetyofcrossconstructionandmutualprotectionoffinishedproducts.Ifpollutionoccurs,itshouldbecleanedupimmediately.
2.Whencarryingoutthenextworkingprocedure,besuretowaituntilthepreviousworkingprocedureiscompletelydry.
3.Constructioninrainyandwindyweathershouldbeavoided,andtheconstructionshouldbestoppedwhentherelativehumidityisgreaterthan80%.
4.Theunusedtopcoatshouldbecoveredtopreventashfallingandcrusting.
5.Materialsmustbekeptindoorstopreventfreezinginwinterandnotexposedtothehotsuninsummer.
6.Forthepaintingoftowercranes,scaffoldingholes,roofsnearthegroundandotherspecialparts,thespecificschemeisrelatedto
Implementationafterconsultation.
ChapterVIConstructionProgressPlan
XXX9ofJuntaiConstructionProject
ConstructionSchemeofReflectiveThermalInsulationCoatingforExteriorWallofThreeResidentialBuildings,TwoCommercialBuildingsandOneUndergroundGarageinSFGarden
Accordingtoourcompany'spreviousconstructionexperienceandconstructiontechnicalforce,thebidperiodofthisprojectiscompletelyguaranteed,andthespecificwork
Theplanschedulewillbeformulatedaccordingtotheactualsituation.
ThisprojectisplannedtostartconstructiononMarch1,2020,andtheplannedcompletiontimeisApril30,2020.Theproject
Thetotalconstructionperiodis60days.
ChapterVIIResourceDemandPlan
1.LaborDemandPlan
Mainlabordemandscale
Noteofserialnumberofworkunitquantity
1generalworker15
2Painters40
3Electrician2
4Mechanic6Hangingbasketassembly
Note:Accordingtotheactualconstructionsituation,necessaryadjustmentscanbemadetoensurethattheconstructionpersonnelcanmeettheconstructionrequirements.
2.DemandPlanforMainMaterialsandTurnoverMaterials:
Everytimethemainmaterialcomesintoplay,20tonsofwaterisneeded.
3,mechanicalequipmentdemandplan:
Listofmainconstructionmachinery
Serialnumbermachinename,specification,model,unitquantity
1materialhoistJJM-3sets1
2AutomaticelectrichangingbasketZLP630hangingbasketplatform20
3.Rope120m.Strip10
4stirringrod/root5
5airlessspraygunGRACO395TTaiwan6
6Powercable3×6+1×4m600
Note:Accordingtotheactualconstructionsituation,necessaryadjustmentscanbemadetoensurethattheequipmentmeetstheconstructionrequirements.
4.Demandplanforlargetoolsandappliances:
1.Brushandmeasuringtoolssuchaslineruler,brush,combinationbrushpen,bucket,balanceandscale.
XX10ofJuntaiConstructionProject
ConstructionSchemeofReflectiveThermalInsulationCoatingforExteriorWallofThreeResidentialBuildings,TwoCommercialBuildingsandOneUndergroundGarageinSFGarden
2,supportingspecialrolleranduniformplateandotherrollercoati
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- AI与职业发展如何抓住机遇
- 企业信息安全管理与风险控制
- 大数据时代的财务管理挑战与机遇
- 二零二五55、WTO的重要协议
- 法律案例解读短视频行业跨境出海战略研究报告
- 家教合同模板二零二五年
- 仓储安全管理系统升级行业跨境出海战略研究报告
- 耐光性有机颜料行业跨境出海战略研究报告
- 学校物业协议合同
- 电子书与有声书制作与发行行业跨境出海战略研究报告
- 社会组织年检培训课件
- (正式版)实习岗位-OFFER通知书
- 人事行政管理培训课程
- 《营养与肥胖》课件
- 绿色生态中小学生校服
- 全宋词目录完整版本
- 支付宝解除账户支付申请书
- 桂林电子科技大学国防科技泄密事件报告表
- 单原子催化剂
- 特许经营管理手册范本(餐饮)
- 手术室护理实践指南之术中保温(手术科培训课件)术中低体温的预防
评论