1、PROPOSAL FOR VERTICAL ADDITIONAL HANDLING2PVH guidelines on vertical additions - 1Additional floor, occupied substantial part of top floor (25%), usually used for production, warehouse, built with concrete or steel.ZT issueFactory needs to:Obtain building certificate, orGo through 3rd party loading

2、assessment and obtain the report shows its safe, orRemove the addition.MezzanineZT issue if there are workers working on or under the mezzanine floor on frequent basis.Non compliance CIA issue if there is no worker working on or under the mezzanine floor or a few workers working on in and out basis.

3、Factory needs to:Go through 3rd party loading assessment and obtain the report shows its safe, orRemove the addition12Administrator2018-06-25 08:06:08-屋顶加盖不能超过25%Administrator2018-06-25 08:07:48-解决方式:获取第三方房屋检测报 告/拆掉违建建筑Administrator2018-06-25 08:08:38-不能设置阁楼Administrator2018-06-25 08:09:12-解决方式:第三方房

4、屋检测报告 /拆掉Administrator2018-06-25 08:19:07-屋顶违建都不行,25%后来有修改。 只要是违建都不行3PVH guidelines on vertical additions - 2Shed but with space for storage and occupied more than 25% of top floorZT issueFactory needs to:Go through 3rd party loading assessment and obtain the report shows its safe, orRemove the addi

5、tionWater tankPartial CIA issue (ZT issue if proved to be unsafe)Factory needs to:Go through 3rd party loading assessment and obtain the report shows its safe, orRemove the addition34Administrator2018-06-25 08:10:08-屋顶安装雨篷、架空层Administrator2018-06-25 08:11:13-解决方法:第三方房屋检测 报告/拆掉Administrator2018-06-25

6、 08:11:52-设计之外加装的水箱Administrator2018-06-25 08:12:18-解决方法:第三方房屋安全 检测/拆掉4PVH guidelines on vertical additions - 3Facilities as garden, basket ball court, tennis court, pond, and etc.Partial CIA issue (ZT issue if proved to be unsafe)Factory needs to:Go through 3rd party loading assessment and obtain t

7、he report shows its safe, orRemove the additionSmall hut used for storing light sundries, AND occupied less than 25% of top floor space.Partial CIA issue (ZT issue if proved to be unsafe)Factory needs to:Go through 3rd party loading assessment and obtain the report shows its safe, orRemove the addition56Administrator2018-06-25 08:12:59-篮球场、花园、池塘等Administrator2018-06-25 08:14:28-解决方式:第三方房屋安全 检测/拆掉Administrator2018-06-25 08:16:41-临时搭建,不能超25%Administrator2018-06-25 08:17:14-解决方式:第三方房屋安全 检测报告/拆掉5PVH guidelines on vertical additions - 4Equipment as Solar Pe

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论