1、实用文档流氓ONIM理方法汇编一、华为厂家:故障现象: 某局点报障OLT 0/5/6 pon 口下绝大多数ONT5法上线,现场更 换分光器后,ont正常上线一会儿,约10分钟时间后故障再次出现,之后PONC 下大量ON柞部处于离线状态。处理过程:1 .查看POND下ont状态,绝多数光猫均处于离线状态,个别 ont在线。0/5/6 0 1047-80E3-0C58 active offline initial initial no0/5/6 1 AC4E-91EC-3217 active offline initial initial no0/5/6 2 AC4E-91EB-A553 acti
2、ve offline initial initial no0/5/6 3 4CB1-6C9A-8D34 activeonline normal mismatch no0/5/6 8 1047-80E1-646E activeonline normal mismatch no0/5/6 16 FCC8-9714-52EE active offline initial initial no0/5/6 17 344B-5080-BAF6 active offline initial initial no0/5/6 18 AC4E-91E9-3D2D active offline initial in
3、itial no0/5/6 24 04C1-B967-F0D8 active offline initial initial no0/5/6 32 04C1-B967-A452 active offline initial initial no0/5/6 40 04C1-B967-CB80 active offline initial initial no0/5/6 41 AC9C-E4BD-46BD active offline initial initial no0/5/6 42 04C1-B967-E052 active offline initial initial no2 .根据客户
4、反馈的故障现象,怀疑 PONH下存在流氓onto查看pon 状态, 系统检测显示pon 口下存在非法入侵的流氓ont,且查看到ont最后一次下线 原因为LOSi。如下:XJ-ALT-MA5680T-2(config-if-epon-0/5)#display port state 6实用文档F/S/P 0/5/6Optical Module status OnlinePort state OnlinexPON MAC chipset state NormalLow time lapse -Last down cause -Last up time 2014-04-17 18:01:32+08:0
5、0TX power(dBm) 4.81Illegal rogue ONT Existent / 显示存在流氓 ontMax rate(Kbps) 1300000Max Distance(Km) 20Wave length(nm) 1490Fiber type Single ModeSignal detect NormalTX fault NormalIdentifier SFP选取某个ONT查看它最后一次离线原因为 LOSi。XJ-ALT-FY-ZXJ-MA5680T-2(con巾g)# display ont info 0 5 6 8F/S/P : 0/5/6ONT-ID : 8Contro
6、l flag : activeRun state : onlineConfig state : normalMatch state : mismatch实用文档Last down cause : LOSiLast up time : 2014-04-17 18:52:29+08:00Last down time : 2014-04-17 18:51:31+08:00Last dying gasp time : 2014-04-15 01:48:00+08:00ONT online duration : 0 day(s), 0 hour(s), 2 minute(s), 38 second(s)
7、3 .进入单板模式,进入pon板,将该PON口 0/5/6下所有ont全部deactivate ,然后逐个逐个执行ont active 操作,故障依旧,所有ont均无法 激活。4 .全局模式下执行命令 anti-rogueont autodetect on打开系统自动隔离检测到的流氓ONT*能开关。几分钟后,设备显示 alarm相关告警信息如下:ALARM 919736故障告警 警告0x2e314022硬件设备类2014-04-1718:42:47+08:00告警名称:ONT1流氓ONT业务影响:影响业务参数信息:机框号:0, 槽位号:5, 端口号:6, ONT ID: 3告警描述:ONT6模
8、块常发光,ONT流氓ONT告警原因:ONTt模块常发光修复建议:(1)隔离ONT(2)替换ONT5 .派人前往现场手工清除更换该流氓 ont后,PONq下其他ont均陆续正常上 线,用户业务恢复正常。此时设备 alarm告警如下:实用文档ALARM 919766恢复告警 清除0x2e324021硬件设备类2014-04-17 18:57:31+08:00告警名称:端口下的非法入侵流氓ONTB经被清除业务影响:不影响业务参数信息:机框号:0,槽位号:5,端口号:6告警描述:端口下的非法入侵流氓ONTB经被清除告警原因:端口下非法入侵的流氓 ONTB被替换修复建议:无需处理关闭设备自动隔离检测到的
9、ont6 . 执行命令 anti-rogueont autodetect off功能开关。问题解决。对于流氓ONU勺判定,还可以通过U2000网管进行判断登录U2000网管客户端,进入设备面板查看 PONH状态,可以看到PONT时候 存在流氓ONU勺显示:运行状态"1在豌操作状窿蛆播分配带宽(KLiWs)=716300乘除保证带宽(KLit/s)-112136可用剜余帮宽(Kbitys)<=LZ3D59N组播使用带宽(Khit/a)=0非法入屋的辅tMNU工不存在j最后一 灾上线时间=05/25/20L5 11:46x27最后一次下线时值=08/29/2015 11:46:34
10、辰后一次下裁原因=L”解决方法:现场手工清除更换掉该ont后,pon 口所有ont全部正常上线,问题解决总结和建议:实用文档关于流氓ont问题,总结如下:1 .流氓ont定义:由于PONk行时分复用,每个ONT艮据OLT分配的时间戳向 上行方向发送数据包。当某个 ONT&没有分配时间戳的时候发光的话,就会与 其他ONT勺发光信号发生冲突。我们把这种不按照分配的时间戳向上发送光信号的ONT叫流氓ONT2 .流氓ONTi要分为以下两种:1) .长发光流氓ont: ont 一直在发光(任何时刻都在发光)。2) .乱发光流氓ont:在非OLT分配的时间戳内发光,可能是提前发光,或者 是延迟关断
11、等。3) 流氓ONT常见故障现象:1) .如果该ONT已上线,会导致同一 PONH下其他某个ONRE者所有ONTF线 (离线)或者大部分ONTS繁上下线。2) .如果该ON怵配置,会导致OLT设备下其他未配置的ONTS法正常自动发 现。4.流氓ont问题常见解决办法:当怀疑PONH下存在流氓ont时,一般在PON口下将所有ont全部deactivat 然后逐个逐个active的方法往往并不能解决问题,现网常见的解决问题办法如 下:1)对于长发光流氓ont,处理起来比较简单,如上案例。一般采取在 OLT设备 上自动隔离检测流氓ont的方法。命令为:anti-rogueont autodetect
12、 on(OLT配置该命令后,系统检测到流氓ONT寸,上报告警信息并将该流氓 ONTS置为隔离状态。处于隔离状态的流氓 ONT只能接收信息,不能发送数据。(命令使用限制条件:1、系统只能检测长发光的流氓ONT2)对应PON口下的ONT、须全部要支持华为扩展 PLOAM1息、(GPON ;或扩展 OAM肖息、(EPON )。另外注意:1. GPBC单板仅支持长发光流氓 ONT佥测,不支持排查和隔离。2. EPBA单板不 支持长发光ont检测。实用文档2),对于乱发光流氓ont,需要通过现场手工逐个排查的方法来解决。a.现场在分光器处将分支光纤全部拔掉,然后一根光纤一根光纤的插。插入 第一根分支光纤
13、,ont正常上线后,再插入第二根分支光纤。依次进行,当插 入某根分支光纤后,PO以下其他ont出现离线故障,证明该分支光纤有问题或 者下挂ont是流氓ont ob.现场在分光器侧使用光功率计来测量 ont的发送光功率,以此来判断流氓 ont的存在。光功率计波长选择1310nm逐个测量ont上行发送给OLT设备的 光功率值。在1分钟之内观察光功率计读数情况变化。如果光功率计一直没有 读数,说明不存在流氓ont;如果光功率计一直有读数,证明存在长发光的流 氓 ont;如果光功率计时而有读数,时而没有读数,则该测量处存在乱发光的流氓ONT流亡K ON3义:正常情况下ONUg光时隙是由OLT控制的,但
14、是当ON3 光时隙不再受OLT控制并且其光模块处于长发光或乱发光状态。这样的 ONIM 叫流氓ONU如何检测流氓ONU长发光ONU问题解决方案1、在断开OLT的情况测试上行光功率,看是否上行长发光, 如果和OLT 断开,上行还有光功率的,有可能光网络中不小心接入了光猫等长发光的 设备或者下面有ONUfe发光。如果版本支持检测的情况下打开流氓ONU佥测开关: ZXAN(config-pon)#rogue-onu-detect 2 enable locateenable auto-shutdown enable2、在C300上打开流氓ONU佥测开关实用文档(config-pon)#rogue-on
15、u-detect 5 enable locate enable auto-shutdownenable /此处的数字5代表槽位号,locate enable 表示打开流氓ONUt位 开关,auto-shutdown enable 表示自动关闭流氓 ONU 3、在C300上查看流氓ONU&警(由于C300对ONIU勺检测是采用逐个ONU顺序Rogue检查的方法,需要等一段时间后再查看告警ZXAN#show logging alarm | includeONUAn alarm 35279 level 0 occurred at 18:47:49 08/10/2012 UTCsentby M
16、CP GPON alarm Rogue ONU detected: shelf 1 slot 5 olt 1 onu 1 level 0on当C300检查到该流氓ONUf,会自动关闭该ONU长发光ONIM关闭之后,其 他正常ONU&自动上线,后续需要将检测到的流氓ONUS行更换,排除隐患。4、在OLT上启用检测流氓onu的功能(该功能需要onu支持)rogue-onu-detect 2 enable locate enable auto-shutdown disable第一个参数2是槽位号,locate是长发光onu位置使能,也就是长发光告警的 位置(定位为哪个onu长发光),auto
17、-shutdown是自动关闭长发光的onu, enable 是关闭,disable 是不关闭。三、贝尔厂家:故障现象:OLTT带的PONffl户(对应 OLT PON端口 1/1/2/2 ,该PON?大约25个ONT8户)不定时出现闪断,故障表现为 ONTB户不停上线下线,闪断频率时快 时慢,没有规律,且误码率增长非常迅速,具体 10g信息如下:实用文档15/02/09 01:29:11 major alarm occurred for ont 1/1/2/2/36 (serviceaffecting) : ONT is inactive15/02/09 01:29:11 major alar
18、m occurred for ont 1/1/2/2/27 (serviceaffecting) : ONT is inactive15/02/09 01:29:14 major alarm occurred for ont 1/1/2/2/25 (serviceaffecting) : ONT is inactive15/02/09 01:29:16 major alarm occurred for ont 1/1/2/2/23 (serviceaffecting) : ONT is inactive15/02/09 01:29:16 major alarm occurred for ont
19、 1/1/2/2/18 (serviceaffecting) : ONT is inactive15/02/09 01:29:16 major alarm occurred for ont 1/1/2/2/16 (serviceaffecting) : ONT is inactive15/02/09 01:29:16 major alarm occurred for ont 1/1/2/2/15 (serviceaffecting) : ONT is inactive15/02/09 01:29:16 major alarm occurred for ont 1/1/2/2/13 (servi
20、ceaffecting) : ONT is inactive15/02/09 01:29:16 major alarm occurred for ont 1/1/2/2/5 (service affecting): ONT is inactive15/02/09 01:29:16 major alarm occurred for ont 1/1/2/2/3 (service affecting): ONT is inactive15/02/09 01:29:16 major alarm occurred for ont 1/1/2/2/2 (service affecting): ONT is
21、 inactive15/02/09 01:29:16 major alarm cleared for ont 1/1/2/1/21 (service affecting): 1490 Optical signal level too low15/02/09 01:29:16 major alarm cleared for ont 1/1/2/2/25 (service affecting): Signal Degraded from ONT15/02/09 01:29:16 major alarm cleared for ont 1/1/2/2/18 (service affecting):
22、Signal Degraded from ONTZZLY-NKeSuo-7360-33.227>#show pon ber-stats 1/1/2/2ber-stats tablepon-idx |ont-num|bit-err-down|bit-err-up|ranged-ind实用文档+1/1/2/2120420771ranged1/1/2/224171552461ranged1/1/2/23229183526ranged1/1/2/2421283611ranged1/1/2/254053645598ranged1/1/2/26109918100not-ranged1/1/2/271
23、855089591ranged1/1/2/282785352530not-ranged1/1/2/29572787475ranged1/1/2/2101893068826ranged1/1/2/2112173962846not-ranged1/1/2/2122292728350not-ranged1/1/2/2133604562798ranged1/1/2/2142434956220not-ranged1/1/2/2152691176529ranged1/1/2/2162285148not-ranged1/1/2/2172625392128ranged1/1/2/218415137896ran
24、ged1/1/2/2192382276648not-ranged1/1/2/2202595904572not-ranged1/1/2/2212105086538ranged1/1/2/2222434734875not-ranged1/1/2/2231823672936ranged故障分析PONfc术是一种点对多点的光纤传输和接入技术,下行OLT将全部信号广播出去,通过ODW配到各ONU每个ON顷受到所有信号,但只取出属于自己 的信号。上行则采用TDMA勺传输方式,每个ONUS各自预定的时隙内发送光信 号。所有ONU勺突发光彳S号通过ODN匚合后形成包括所有ONUB息的突发光信 号。OLT接收所
25、有信号后再根据协议处理。结合PONT作原理及本次故障现象,分析故障原因为:1 .所有故障只集中在1/1/2/2这一个PONH上,当ONTW户发生I闪断时,OLTM实用文档应的POND 1/1/2/2能看到大量的误码存在(其他PON匀没有误码),且一直快 速增长,累计可达几十万。而在正常情况下,该部分数值应该为0或偶尔增长最 多累计到几十几百的数量级。因此可以确定是因为误码快速变化导致了整个PON口下的ON磔中发生闪断。2 .分析产生误码的原因:在 PON网络中,导致误码快速增长的可能原因有:流氓ONT(某台ONT长发光或乱发光),或中间光路问题,或 PON光模块问题。而故障发生后该PON 口的
26、主干光路及分光器等均做过替换,因此光路应该没问题,但故障依旧反复,因此基本判断是流氓 ONT!致了故障。处理过程流氓ONTa理过程相对较复杂,并且可能需要用户方面的配合,下面简述此故障 的现场排查过程:1 .通过流氓 ONTHE查命令 admin pon diagnostic 1/1/2/2 modeinit-onofftest 诊断流氓 ONT(中断命令为 admin pon diagnostic 1/1/2/2 mode stop ),但没 能成功定位故障ONT2 .长时间跟踪告警打印log,没能发现某台ONT!致其他ONT艮随中断和误码 迅速增长的规律。3 .人工对整个故障PONH进行排
27、查(PON1/1/2/2 光路情况为:PON出来经1:2 分光器分两路到不同的主箱):1)在主分光器位置,把其中一个主箱(假设 A路)下的所有ONT光路拔掉,观 察发现另外一主箱(假设B路)下部分ON琢口的误码仍然快速在增长;2)恢复A路,拔掉B路,发现A路下面的用户误码没有增长,初步判断是B路引起;3)对B路ONT1户分段排查后发现,ONT1/1/2/2/16 异常。隔离该ONTf 1/1/2/2 PONI码不再增长;把1/1/2/2其他用户恢复后,观察误码没有再快速增长。而 把ONT 1/1/2/2/16接上后误码又迅速增长。4)在该用户家测量OLT发过来光功率大约在-20dbm,判断光路没有问题。更换 该ONTt观察,该PONT带ONT匀正常运行,没有再出现闪断。而该PONT误码 迅速大量增长的情况也未再出现。流氓ONT非查思路实用文档针对现场流氓ONT勺排查思路如下:1 .判断此类故障的主要手段是检查故障PONT的误码率是否快速大量的增长(几秒钟内成千成万数量级的增长)。2 .用命令 admin pon diagnos
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2024年BRC食品企业内部控制培训课件
- 2025届河北省保定市高三上学期10月期中地理含答案
- 2024琥珀教学课件:解读树脂中的历史信息
- 2024届新高考生物必刷题12 基因工程(共50题)(原卷版)
- 疑难病例讨论记录范文上睑下垂
- 四年级语文楚才杯小青蛙上网记1
- 2024-2025学年新教材高中政治第三单元文化传承与文化创新第8课第2框文化交流与文化交融学案部编版必修4
- 八年级数学下册单元清一新版华东师大版
- 2024-2025学年新教材高中化学第4章化学反应与电能第3节金属的腐蚀与防护课堂达标含解析新人教版选择性必修第一册
- 2025届高考生物一轮复习课后限时集训25人体的内环境与稳态含解析新人教版
- 消防安全培训内容
- 2024-2030年辣椒种植行业市场深度分析及发展策略研究报告
- 变电站绿化维护施工方案
- 校园展美 课件 2024-2025学年人美版(2024)初中美术七年级上册
- 2024版《糖尿病健康宣教》课件
- ktv保安管理制度及岗位职责(共5篇)
- 脑出血试题完整版本
- 义务教育信息科技课程标准(2022年版)考试题库及答案
- 建筑施工安全生产责任书
- 新员工三级安全教育考试试题参考答案
- 公司年会策划及执行服务合同
评论
0/150
提交评论