版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1、operation & service manualportable dental unit du series jiangsu dynamic medical technology co.,ltd.note: before operating or maintenance the unit, please read the manual carefully. this manual is just for guidance, and our company has the right to improve the design.this manual will guide you t
2、o operate the light precisely. please read all accompanying documents before the first use!disclaimerthis manual doesn't refer to any description of dynamic products' specifications and accessories. if you have any questions about these two aspects, please read the according agreement and pa
3、cking list, or contact the agents directly.we have made great efforts to write this manual correctly and completely. but because of the continuous advance for technology and the amendments for relevant laws, we may make some changes to products and manuals. we reserve the right to change without any
4、 other previous declaration. we promise to improve our products and service continuously. if you find inconformity between manual and product, want to know latest information, or have any questions, please visit our website!limited warranty for the device with warranty document, we will provide afte
5、r-sale service referring to the warranty document only. for the device without warranty document, we will provide after-sale service referring to the agreement. it means this purchaser dont have the right to enjoy our after-sale service. so, if you want to buy such kind product, you should require t
6、he seller to promise you after-sale service.this product could be sold in the countries and regions where it meets laws only.in the maximum limit of law permitting, in the following conditions, we assume no responsibility:1. the third party requires you to compensation.2. incidental or indirect inju
7、ry and economic loss.3. any injury and economic loss because you add other equipments to this product personally.4. any injury and economic loss because you use the product in conditions not referred in manual, or you dont operate the product according to manual.5. any injury and economic loss becau
8、se of force majeure factors.you could call our after sale service number:ote: maybe this number will be changed due to communication network or some other objective factors, and we will give no further notice.copyrightjiangsu dynamic has the copyright of this manual, and holds all
9、the rights.the copyright of other accessories and documents equipped with our products belongs to the according organizations or persons.marksnotice: risk of losing accessories and documentscaution: risk of injury or malfunction figures iread carefully of the manual ono ground protective off serial
10、number manufacturer producing date eu representative information electron garbage bin6. version informationoperation manual no.dl-du-ce-1301-017. modeldu852、du893、du892、du895、du895a、du896、du810、du811du812、du800、du752content1. brief introduction 42. technical parameters 63. product structure and inst
11、allation 114. test and application 205. operation and maintenance 226. trouble-shooting 247. fundamental diagram 258. water and air diagrams of du portable dental units 269. circuit diagrams of du dental units 3010. attentions 3211. labels on outside packing 3212. packing list 331. brief introductio
12、nthank you for purchasing our du portable dental units. it is our companys well-developed multi-purpose mechanical and electrical integration of energy-saving product with small, mobile, good appearance, less power consumption, free maintenance, safe and durable etc. it is mainly used for clinics an
13、d hospitals in the treatment of oral health. in order to be convenient for you to operate the unit, please read the manual carefully.1.1 contents of the manual the operation manual includes brief introduction, installation and test, maintenance and so on. you can get help referring to the contents.1
14、.2 performance and structuredu portable dental units include 3-way syringe, handpiece, foot control, clean bottle, drain bottle, built-in oil-free air compressor, air tank, and drawbar.1.3 main applicationmainly applied in dental clinics and hospitals, as one of the main units for dental hygiene and
15、 treatment.1.4 safety information 1.4.1 electric safety to make sure that the plug of this product is three-phase with good grounding. before connect the power plug, please ensure the power voltage consistent with the named voltage which this product required. to avoid unsteady voltage, please do no
16、t use the power socket together with other electric equipment. before maintain or repair the product, please unplug that electric wire firstly. please check the electric wire and plug regularly to avoid the damage or extrusions. 1.4.2 cleaningplease keep the environment around the product clean. unp
17、lug that electric wire before cleaning the machine. the process of cleaning as follows: firstly wipe the outer surface with a soft cloth stained with neutral detergent, and then use a soft cloth to clean the machine again. warning: do not use liquid or detergent containing flammable substances. 1.4.
18、3 other safety informationwhen using the product, please strictly operate the machine in according to the following rules:1) disinfection and sterilization before use, disinfection and sterilization are necessary to avoid the infection caused by bacterium and virus.2) in treatment, it is necessary f
19、or the patient to breathe only by nose to avoid the risk of swallowing the cracked equipments.3) the handpieces should be operated with distilled water simultaneously. if operate the handpieces without distilled water, the handpiece will overheat and cause damage to the teeth.4) please note that the
20、 power plug is designed as the safety device, not power switch. it is necessary to ensure the power plug can be unplugged from the socket without extrusions.warning: correct grounding is necessary to avoid the risk of electric shock.5) only skilled staff through training can operate the equipment. u
21、ndue operation may cause severe injury.6) equipment cannot be used in flammable mixture environment.7) equipment cannot be used in anesthetic and air, oxygen, nitrogen mixture environment.8) don't put the equipment together with oxygen cylinder.9) please do not operate the equipment or replace t
22、he accessories when the following situations occur: damage of the power plug equipment cannot work normally breakdown of the equipment water inlet of the equipment loud or shrill noise, overheating outlet air or foul smells during operation.when above situations occur, please contact with the manufa
23、cturer or local agent. in order to be convenient for us to offer after sale service, please offer drawing of electrical circuit, air and water connection diagram, packing list and other useful information when necessary.10) please use original or qualified disinfector.11) turn off the power when the
24、 operator left.12) dispose of waste liquid and waste solid according to the local health regulations.13) do not use and store the equipment outside the specified environment.14) keep accessories from dropping to avoid damages.15) keep the electric wire from loosing in the process of treatment.16) pl
25、ease use accessories from original manufacturer.17) keep the equipment in a solid and horizontal level.1.5 periodic safety inspectionsthe following projects should be inspected at least once a year by the trained and skilled person:check the equipment and the functional status of the machinery in th
26、e attachment.check whether the mark of the related safety is clean or notcheck whether the blown fuse accords with the current rating fuse and the characteristiccheck whether the performance of the equipment accords with the description in the manual.testing whether the ground resistance is less tha
27、n the required resistance described in the iec60601-1: 0.1ohm.testing whether the earth leakage current is less than the required resistance described in the iec60601-1: normal condition: 500ua, single fault condition 1000ua.testing whether the shell leakage current is less than the required electri
28、c current described in the iec60601-1: normal condition: 100ua, single fault condition: 500 ua.testing whether the patient current leakage is less than the required electric current described in the iec60601-1: for the alternating current: 0.5ma, for the continuous current: 10 ua.testing whether the
29、 patient leakage current is less than the required current described in the iec60601-1 in the single fault condition: for the alternating current: 0.5ma, for the continuous current: 50ua.testing whether the auxiliary leakage current is less than required current described in the iec60601-1: the alte
30、rnating current in the normal condition: 0.1ma, for the continuous current 10ua;the alternating current in the single fault condition: 0.5ma, for the continuous current is 50 ua.write down all the test data on the operational diary, if the above test is failed or the equipments can not work normally
31、, then you should maintain the equipment.1.6 the requirements of external components1.6.1 all external parts must be certified by ce, and also you need to check technical parameters related to spare parts, sketch map, technical manuals and instructions, production qualification test report and other
32、 contents.1.6.2 check whether the parts will accord with the requirements of the company before installation the parts.1.6.3 the installation parts should be operated by the trained person.1.7 all modelsdu852, du893, du892, du895, du895a, du896, du810, du811, du812, du800, du7522. technical specific
33、ations2.1 power parameterfigure 1modelvoltage/frequency powerspecificationnet weightdu752230v 50 hz550va615×500×790 mm30kgdu852230v 50 hz550va450×310×680 mm26kgdu892230v 50 hz550va450×310×680 mm26kgdu893230v 50 hz550va450×310×680 mm28kgdu895230v 50 hz550va420&
34、#215;300×480mm26kgdu895a230v 50 hz550va420×340×570 mm31kgdu896230v 50 hz550va495×330×450 mm24kgdu810/970×390×290 mm18 kgdu811/610×580×850 mm26kgdu812/610×580×850 mm26kgdu800/450×310×680 mm12kg2.2 performance and accessoriesfigure 2no.m
35、odelperformance and accessoriestankmotorunith.s. handpiece tubel.s. handpiece tubeinstrument tray3-way syringesaliva ejectorled curinglightscaler1pc2pcs1.du 7522.du 8523.du 8924.du 8935.du 8956.du895a7.du 8968.du 8109.du 81110.du 81211.du 800note: “” basic accessory, “” optional accessorywarning: pl
36、ease operate the unit strictly under the named supply voltage, because the unsteady current can cause injuries to the unit. please install power voltage regulator when supply voltage is unsteady, and the rated power is no less than 1000va.2.2.1 air supply parameterthe air supplied by the built-in co
37、mpressor is clean and dry (air pressure: >0.55mpa, air flow: >50lmin ). if the compressed air is wet, press the drain valve to drain off the water in tank timely.2.2.2 water supply parameterthe water offered for the handpiece and other parts is directly from clean bottle; please refill the bot
38、tle with distilled water timely.2.3 product classification2.3.1 classification of electric shock protection: type i equipment.2.3.2 classification of electric shock guarding: type b equipment.2.3.3 classification of waterproof: normal equipment.2.4 conditions of transportation, storage and applicati
39、on2.4.1 transportation and storagethe machine should be transported and stored in following condition:temperature: -10+50range of relative humidity: 90 range of atmospheric pressure: 50kpa 106kpa2.4.2 working conditiontemperature: 540 relative humidity: 80 atmospheric pressure: 86kpa 106kpathe machi
40、ne should not be used in the environment with a mixture of flammable anesthetic, oxygen and nitrogen. 2.5 electromagnetic compatibilitythe machine pass the electromagnetic compatibility test of iec60601-1-2, should you have any questions, please contact our service department, thank you! electromagn
41、etic emission standards and our announcementdu series dental unit should be used in following electromagnetic environment, and the use of this product should ensure to use under suitable environment.electromagnetic emission teststandardselectromagnetic environment standardsradiation electromagnetic
42、disturbancecispr 11 i forma classelectromagnetic emission of du series dental unit can only satisfy its inherent functions, so its wireless radiation level is so low, that could not effect the contiguous electronic equipment. power disturbance voltagecispr 11 i forma classharmonic emissioniec 61000-
43、3-2du series dental unit can used by all companies and institutes, and could not connect with household or public low voltage power system.voltage fluctuation/flashiec 61000-3-3electromagnetic emission standards and our announcementdu series dental unit should be used in following electromagnetic en
44、vironment, and the use of this product should ensure to use under suitable environment.electromagnetic emission testiec 60601 test valuestandardselectromagnetic environment standardselectrostatic discharge (esd)iec 61000-4-2±6 kv touch±8 kv air±6 kv touch±8 kv airthe materials of
45、 floor should be wood, concrete and ceramic tile.if the floor is synthetic material, relative humidity no less than 30. eft iec 61000-4-4±2kv power supply line±2kv power supply linethe quality of power supply is used in special commerce or hospital. surge (impact) iec 61000-4-5±1 kv l
46、ine to line mode±2 kv line to earth mode±1 kv line to line mode±2 kv line to earth modethe quality of power supply is used in special commerce or hospital.voltage sag and short supply interruption voltage changeiec 61000-4-11<5% ut (>95% dip in ut)for 0.5 cycle40% ut(60% dip in
47、ut)for 5 cycles70% ut(30% dip in ut)for 25 cycles<5% ut (>95% dip in ut) for 5 sec<5% ut (>95% dip in ut)for 0.5 cycle40% ut(60% dip in ut)for 5 cycles70% ut(30% dip in ut)for 25 cycles<5% ut (>95% dip in ut)for 5 secthe quality of power supply is used in special commerce or hospit
48、al. when du series portable dental units need to continuous operation when grid interrupts, please use uninterruptable power output.power frequency magnetic fields iec 61000-4-83a/m3a/m/note: ut is alternating voltage before testing.electromagnetic emission standards and our announcementdu series de
49、ntal unit should be used in following electromagnetic environment, and the use of this product should ensure to use under suitable environment.protection testiec 60601 test valuestandardselectromagnetic environment standardsradio transmissioniec 61000-4-6radio radiationiec 61000-4-33 vrms150 khz to
50、80 mhz3 v/m80 mhz to 2.5 ghz3 vrms3 v/mportable or mobile radio communication equipment should stay away from du series portable dental unit, including cables, also should leave more than the recommended separation distance calculated.recommended separation distance80 mhz 800 mhz800 mhz 2.5 ghzp: is
51、 the fixed output power by radio equipment manufacturer, the unit is w. d: recommend separation distance. fixed radio transmitter, determined by electromagnetic measurements, a: each frequency band must be less than the standard requirements. b: the equipment maybe interfered nearby the device with
52、following symbols:note: 1between 80 mhz and 800 mhz, higher frequency range applies. 2this specification maybe do not suitable for all situations, because the propagation of electromagnetic waves can be effected by the absorption and reflection of buildings, objects and people.a: the electromagnetic
53、 strength of fixed radio transmitter, such as radar station, cordless telephone and mobile radios, amateur radio, fm and am radio and television, this can not be predicted in theory. the estimated of electromagnetic environment depends on the fixed radio transmitters, and electromagnetic measurement points should be considered. if the magnetic strength nearby the du series is more than the above allowed value, then du series portable dental unit should
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2024户外广告牌制作安装合同
- 2024年合作投资协议书模板
- 2024苗木购销合同范本简单版
- 2024股东合作经营合同协议书
- 城市街道广告位租赁合同
- 插画约稿合同样本
- 二房东租房合同租房合同协议范本
- 2024股份制工程合作协议书
- 货物运输合同签订技巧
- 4.1 夯实法治基础(导学案) 2024-2025学年统编版道德与法治九年级上册
- (培训体系)2020年普通话测试培训材料
- 3-4单元测试-2024-2025学年统编版语文六年级上册
- 北师版数学八年级上册 5.8三元一次方程组课件
- 2024混合动力汽车赛道专题报告-2024-10-市场解读
- DB34T 4338-2022 行政规范性文件合法性审核规范
- 企业单位消防安全规范化管理指导手册
- 废旧物资回收投标方案(技术方案)
- 宣传视频拍摄服务投标方案(技术方案)
- 森林防火课件下载
- 3《欢欢喜喜庆国庆》(教学设计)2024-2025学年统编版道德与法治二年级上册
- 2024粮改饲工作总结五篇
评论
0/150
提交评论