文档简介

精品文档 I欢迎下载I欢迎下载 MARITIMEMARITIME TERMINALTERMINAL OFOF PETROCHEMICALPETROCHEMICAL COMPLEXCOMPLEX TechnicalTechnical SpecificationSpecification ofof LoadingLoading ArmsArms C C NO NO 13303 13303 CLIENT CLIENT NO NO 11 11 ChinaChina H H September September 20152015 IssueIssue status status 0C Sep 2015 2014 FOR APPROVAL Rev DateDescriptionPrep dChk dRev dApp d 精品文档 II欢迎下载II欢迎下载 CONTENTSCONTENTS 1 1GENERALGENERAL 1 1 1 1FIELD OF APPLICATION 1 1 2DEFINITION OF ITEMS 1 2 2REFERENCEREFERENCE DOCUMENTSDOCUMENTS 3 3 2 1APPLICABLE CODES AND STANDARDS 3 2 2APPLICABLE PROJECT DOCUMENTS 3 2 3EXCEPTIONS TO REFERENCE DOCUMENTS 4 2 4DOCUMENTS ORDER OF PRECEDENCE 4 3 3SCOPESCOPE OFOF SUPPLYSUPPLY 5 5 3 1EQUIPMENT SUPPLY 5 3 2EXCLUSIONS 7 3 3BOUNDARY LIMITS 8 3 4ERECTION WORKS 9 4 4INSTALLATIONINSTALLATION DATADATA 9 9 4 1SITE LOCATION AND ENVIRONMENTAL CONDITIONS 9 4 2AREA CLASSIFICATION 9 5 5GENERALGENERAL SERVICESERVICE CONDITIONSCONDITIONS 9 9 5 1PROCESS 9 5 2OPERATING AND DESIGN CONDITIONS 9 6 6DESIGNDESIGN ANDAND CONSTRUCTIONCONSTRUCTION 1010 6 1MATERIALS 10 6 2DESIGN REQUIREMENTS 10 精品文档 III欢迎下载III欢迎下载 6 3SWIVEL JOINTS AND STRUCTURAL BEARINGS 12 6 4QUICK CONNECT DISCONNECT CARGO COUPLERS QCDC 13 6 5SPOOL PIECES 13 6 6POWERED EMERGENCY RELEASE COUPLINGS PERC 14 6 7ACCESSORIES 15 6 8OPERATING AND CONTROL SYSTEM DESIGN 17 6 9PAINTING MARKING PACKING AND PREPARATION FOR SHIPMENT 21 7 7INSPECTIONINSPECTION ANDAND TESTSTESTS 2121 7 1MATERIALS 21 7 2FABRICATION CONTROLS 21 7 3SHOP TESTS 23 7 4SITE TESTS 25 7 5CERTIFICATION TESTS 26 8 8CRITERIACRITERIA 2626 8 1LEAKAGE 26 8 2PRESSURE DROP 26 8 3CONSUMPTIONS OF STEAM 26 8 4LOADS ON SHIP CROSSOVER FLANGES 26 9 9GUARANTEEGUARANTEE 2727 精品文档 1欢迎下载1欢迎下载 1 1GENERALGENERAL This specification covers the minimum requirements for Marine Loading Arms for use in liquid ammonia and molten sulfur service including design manufacture assembly control shop tests site tests and performances to be installed in the MARITIME TERMINAL OF MORON PETROCHEMICAL COMPLEX The requirements for quick connect disconnect couplers QCDC powered emergency release coupling PERC and loading arm control power systems are also covered In addition to the description in this specification relating data sheets drawings specifications codes and standards shall be referred to conduct the design It should be noted that this specification is not intended to preclude the use of new materials designs or techniques which can be demonstrated to be suitable for the intended service This specification is a contractual document between PURCHASER and SELLER It defines the equipment and services included in the SELLER scope of supply This specification is derived from OCIMF Oil Companies International Marine Forum Design however no dye penetrant inspection is required for root pass of circular welds of pipes on finished welds tightness welds and all pressure containing welds subject to low temperature in order to check the absence of linear indications in compliance with ASME VIII 7 2 4Magnetic particle inspection of carbon steel welds On all lifting component attachments casting welds 7 2 5Visual inspection Longitudinal welds of pipe elements assemblies shall be at a distance of at least 150 mm from each other each pipe element shall have a minimum length of 3 m 精品文档 24欢迎下载24欢迎下载 Superficial defects which are not prejudicial to the use and which affect metal homogeneity or thickness shall be sounded to detect their importance Any superficial defect which after sounding would be proven to have a depth of more than 8 of the thickness shall be repaired Defects of lower importance may be repaired by grinding 7 37 3 SHOPSHOP TESTSTESTS 7 3 1Pressure testing All Marine Arms shall be completely assembled and hydrostatically tested to at least 1 5 x design pressure The pressure test shall be maintained for a sufficient time to determine if there are any leaks but not less than 30 minutes Testing shall take place with the Marine Arm fully assembled and placed in the hydrostatic test position During hydrostatic testing the Marine Arm shall be restrained to reduce any stress from external sources The hydrostatic test will be performed in order to confirm that there is no deformation and no damage or leakage from welded area and flange connections Above test shall be carried out in SELLER s workshop prior to painting Marine Arms shall be dismantled and thoroughly dried after hydrostatic testing Marine Arms to be drained filled with nitrogen and sealed ready for shipment Pneumatic testing shall not be used without the consent of PURCHASER 7 3 2Working range and clearance check When specified in the data sheets one or more Marine Arms shall be erected at the SELLER s workshop in order to verify the parameters and operations according to the design data 7 3 3Swivel testing If required in the data sheets swivel s sheet shall be proof tested at the SELLER s workshop by subjecting the swivel to a swivel test load PCT defined by OCIMF paragraph 12 5 5 without causing permanent deformation to any part of the swivel 精品文档 25欢迎下载25欢迎下载 The swivel shall meet the requirements laid down in section 6 3 and the requirements of OCIMF The maximum acceptable leakage rate for each stage shall be specified 7 3 4Quick connect disconnect cargo coupler testing As required quick connect disconnect cargo couplers QCDC shall be tested for leakage and load capacity When testing is required the test shall demonstrate the QCDC s ability to disengage from the Ships manifold when unbalanced loads are present When testing is required the QCDC shall be tested for accidental release of its grippers due to hydraulic leakage and loss of hydraulic and or electrical power The QCDC shall be strength tested under following conditions a combination of axial load bending moment and shear as per paragraph 12 7 3 and 12 7 4 of OCIMF Design and Construction Specification for Marine Loading Arms internal pressure of 19 kg cm2 or the specified design pressure whichever is higher test loads will be increased stepwise as specified by PURCHASER Above conditions shall be maintained for a sufficient time to determine if there are any leaks but not less than 5 minutes Neither liquid leakage nor permanent deformation in any part shall occur PURCHASER may specify particular requirements concerning test spool material and dimensional requirements 7 3 5Emergency release coupling testing The powered emergency release coupling s PERC shall be proof tested at SELLER works for leakage permanent deformation and release performance 精品文档 26欢迎下载26欢迎下载 The PERC shall meet the requirements laid down in Para 6 6 and shall meet the requirement of OCIMF specification Design Construction Specification for Marine Loading Arms The PERC shall be strength tested under the following conditions an internal pressure of 19 kg cm2 or the specified design pressure see the data sheet whichever is higher when testing of PERC in cryogenic application is specified in the data sheet the coupling shall be tested for leakage and load capacity under ambient and minimum cargo temperature The emergency release coupling shall be tested for accidental release due to hydraulic leakage and loss of hydraulic and or electric power Above tests shall be witnessed by PURCHASER or his representative 7 47 4 SITESITE TESTSTESTS 7 4 1Pressure testing Prior to initial operation the fully assembled Marine Arm shall be pneumatically leak soap tested Either nitrogen or dry air shall be used The test pressure shall be 6 kg cm2 and shall be maintained for a sufficient time to determine if there are any leaks but not less than 30 minutes The pneumatic test shall be carried out to prove tightness of bolted connections gaskets and couplings only 7 4 2Working range and clearance check The SELLER shall after installation of the Marine Arms perform a check on all Marine Arms and on all combinations of loading Marine Arms specified to insure that they will reach all positions of the applicable Ship manifold envelope s at all specified Ship manifold spacing 7 57 5 CERTIFICATIONCERTIFICATION TESTSTESTS Equipment such as pressure vessels or lifting devices shall be submitted to certification test by an authority having jurisdiction 精品文档 27欢迎下载27欢迎下载 Electrical and instrumentation devices installed in a hazardous area shall be provided with certificates of compliance 8 8CRITERIACRITERIA 8 18 1 LEAKAGELEAKAGE Full tightness of Marine Arms at their operating temperature must be satisfied 8 28 2 PRESSUREPRESSURE DRODROP P The pressure drop in liquid ammonia arm and molten sulfur shall not exceed the value defined in the data sheet at the nominal flow rate specified at the lowest highest temperature specified 8 38 3 CONSUMPTIONSCONSUMPTIONS OFOF STEAMSTEAM SELLER shall propose a value for the consumption of steam for jacket tracing of molten sulphur arm 8 48 4 LOADSLOADS ONON SHIPSHIP CROSSOVERCROSSOVER FLANGESFLANGES Loads tensile compressive bending and torsion on Ship crossovers indicated by SELLER are maximum acceptable values 9 9GuaranteeGuarantee Compliance with this specification does not relievethe Seller from their responsibilities for the design construction workmanship and quality of the materials used which shall be fully suitable for the operating conditions specified by OWNER and reliable with regard to its mechanical and operating performance The specified requirements are the minimum ones of the PURCHASER but the SELLER shall be the ultimately responsible for all aspects of the supplied equipment regardless of source and shall be responsible for ensuring compliance with all relevant local and national codes and regulations etc current at the date of tender 精品文档 28欢迎下载28欢迎下载 SELLER shall guarantee that

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论