已阅读5页,还剩6页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
JINGGANGSHAN UNIVERSITY 外文翻译 题 目 调整送料量输送装置设计 学 院 机电工程学院 专 业 机械制造及其自动化 班 级 机制 11 本( 1)班 学 号 110611014 姓 名 蓝善龙 指导教师 康志成教授 起讫时间 2014.12.1 2015.4 教 务 处 印 制 井冈山大学外文翻译 1 Abstract Bulk material transportation requirements have continued to press the belt conveyor industry to carry higher tonnages over longer distances and more diverse routes. In order keep up, significant technology advances have been required in the field of system design, analysis and numerical simulation. The application of traditional components in non-traditional applications requiring horizontal curves and intermediate drives have changed and expanded belt conveyor possibilities. Examples of complex conveying applications along with the numerical tools required to insure reliability and availability will be reviewed. Belt Conveying Systems Development of driving system Among the methods of material conveying emploved, belt conveyors play a very imporient part in the reliable carrying of material over long distances at competitive cost. Conveyor systems have become larger and more complex and drive systems have a l so been going through a process of evolution and will continue to do so. Nowadays, bigger belts require more power and have brought the need for larger individual drives as well as multiple drives such as 3 drives of 750 kW for one belt(this is the case for the conveyor drives in Chengzhuang Mine). The ability to control drive acceleration torque is critical to belt conveyors performance. A efficient drive system should be able to provide smooth, soft starts while maintaining belt tensions within the specified safe limits. For load sharing on multiple drives. torque and speed control are also considerations in the drive systems design. Due to the advances in conveyor drive control technology, at present many more reliable. Cost-effective and performance- driven conveyor drive systems covering a wide range of power are available for customers choices1. 1 Analysis on conveyor drive technologies 1. 1 Direct drives Full-voltage starters. With a full-voltage starter design, the conveyor head shaft is direct-coupled to the motor through the gear drive. Direct 8 full-voltage starters are adequate for relatively low-power, simple- Profile conveyors. With direct full-voltage starters. no control is provided for various conveyor loads and. depending on the ratio between full- and no-load power requirements, empty starting times can be three or our times faster than full load. The maintenance-free starting system is simple, low-cost and very reliable. However, they cannot control starting torque and maximum stall torque; therefore. they are limited to the low-power, simple-profile conveyor belt drives. Reduced-voltage starters. As conveyor power requirements increase,controlling theapplied motor torque during the acceleration period becomes increasingly important. Because motor torque is a function of voltage, motor voltage must be controlled. This can be achieved through 井冈山大学外文翻译 2 reduced-voltage starters by employing a silicon controlled rectifier (SCR). A common starting method with SCR reduced-voltage starters is to apply low voltage initially to take up conveyor belt slack. and then to apply a timed linear ramp up to full voltage and belt speed. However, this starting method will not produce constant conveyor belt acceleration. When acceleration is complete. the SCRs, which control the applied voltage to the electric motor. are locked in full conduction, providing full-line voltage to the motor. Motors with higher torque and pull -vp torque, can providebetterstarting torque when combined with the SCR starters, which are available in sizesup to 750 KW. Wound rotor induction motors. Wound rotor induction motors are 9 connected directly to the drive system reducer and are a modified onfiguration of a standard AC induction motor. By inserting resistance in series with the motors rotor windings. the modified motor control System controls motor torque. For conveyor starting, resistance is placed in series with the rotor for low initial torque. As the conveyor accelerates,the resistance is reduced slowly to maintain a constant acceleration torque. On multiple-drive systems. an external slip resistor may be left in series with the rotor windings to aid in load sharing .the motor systems have a relatively simple a design.However,the control systems for these can be highly complex, because they are based on computer control of the resistance switching. Today, the majority of control systems are custom designed to meet a conveyor systems particular specifications. Wound rotor motors are appropriate for systems requiring more than 400KW. DC motor. DC motors. available from a fraction of thousands of KW, are designed to deliver constant torque below base speed and constant KW above base speed to themaximum allowable revolutions per minute (r/min). with the majority of conveyor drives, a .DC shunt wound motor is used. Wherein the motors rotating armature is connected externally. The most common technology for controlling DC drives is a SCR device. which allows for continual variable-speed operation. The DC drive system is mechanically simple, but can include complex custom-designed electronics to monitor and control the complete system. this system option is expensive in comparison to othersoft-start systems. but it is a reliable, cost-effective drive in applications in which torque,load sharing and variable speed are primary considerations. DC motors generally are used with higher-power conveyors, 10 including complex profile conveyors with multiple-drive systems, booster tripper systems needing belt tension control and conveyors requiring a wide variable-speed range. 1. 2 Hydrokinetic coupling 2. Hydrokinetic couplings, commonly referred to as fluid couplings. are composed of three basic elements; the driven impeller, which acts as a centrifugal pump; the driving hydraulic turbine known as the runner and a casing that encloses the two power components. Hydraulic fluid is pumped from the driven impeller to the driving runner, producing torque 井冈山大学外文翻译 3 at the driven shaft. Because circulating hydraulic fluid produces the torque and speed, no mechanical connection is required between the driving and driver shafts.The power produced by this coupling is based on the circulated fluids amount and density and the torque in proportion to input speed. Because the pumping action within the fluid coupling depends on centrifugal forces. the output speed is less than the input speed. Referred to as slip. this normally is between 1% and 3%. Basic hydrokinetic couplings are available in configurations from fractional to several thousand KW. Fixed-fill fluid couplings. Fixed-fill fluid couplings are the most commonly usedsoft-start devices for conveyors with simpler belt profiles and limited convex/concave sections. They are relatively simple,low-cost,reliable,maintenance free devices that provide excellent soft starting results to the majority of belt conveyors in use today. Variable-fill drain couplings. Drainable-fluid couplings work on the same principle as fixed-fill couplings. The couplings 11 impellersare mounted on the AC motor and therunners on the driven reducer high-speed shaft. Housing mounted to the drive base encloses the working circuit. The couplings rotating casing contains bleed-off orifices that continually allow fluid to exit the working circuit into a separate hydraulic reservoir. Oil from the reservoir is pumped through a heat exchanger to a solenoid-operated hydraulic valve that controls the filling of the fluid coupling. To control the starting torque of a single-drive conveyor system, the AC motor current must be monitored to provide feedback to the solenoid control valve. Variable fill drain couplings are used in medium to high-kw conveyor systems and are available in sizes up to thousands of kw.The drives can be mechanically complex and depending on the control parameters. the system can be electronically intricate. The drive system cost is medium to high,depending upon size specified. Hydrokinetic scoop control drive. The scoop control fluid coupling consists of the three standard fluid coupling cmponents: a driven impeller, a driving runner and a casing that encloses the working circuit. The casing is fitted with fixed orifices that bleed a predetermined amount of fluid into a reservoir. When the scoop tube is fully extended into the reservoir, the coupling is 100 percent filled. The scoop tube, extending outside the fluid coupling, is positioned using an electric actuator to engage the tube from the fully retracted to the fully engaged position. This control provides reasonably smooth acceleration rates. to but the computer-based control system is very complex. Scoop control couplings are Variable-frequency control(VFC) Variable frequency control is also one of the direct drive methods. the emphasizing discussion about it here is because that it has so unique characteristic and so good performance compared with other driving methods for belt conveyor. VFC devices Provide variable frequency and voltage to the induction motor, resulting in an 井冈山大学外文翻译 4 excellent starting torque and acceleration rate for belt conveyor drives. VFC drives. available from fractional to several thousand (kW), are electronic controllers that rectify AC line power to DC and, through an inverter, convert DC back to AC with frequency and voltage control. VFC drives adopt vector control or direct torquecontrol(DTC)technology, and can adopt different operating speeds according to different loads. VFC drives can make starting or stalling according to any given S-curves realizing the automatic track for starting or stalling curves. VFC drives provide excellent speed and torque control for starting conveyor belts. and can also be designed to provide load sharing for multiple drives. easily VFC controllers are frequently installed on lower-powered convey- or drives, but when used at the range of medium-high voltage in the past. the structure of VFC controllers becomes very complicated due to the limitation of voltage rating of power semiconductor devices, the combination of medium-high voltage drives and variable speed is often solved with low-voltage inverters using step-up transformer at the output, or with multiple low-voltage inverters connected in series. Three-level voltage-fed PWM converter systems are recently showing increasing popularity for multi-megawatt industrial drive applications because of easy voltage sharing between the series devices and iroved 13 harmonic quality at the outputcompared to two-level converter systems With simple series connection of devices. This kind of VFC system with three 750 kW /2. AV inverters has been successfully installed in ChengZhuang Mine for one 2. 7-km long belt conveyor driving system in following the principle of three-level inverter will be discussed in detail. 2 Neutral point clamped(NPC)three-level inverter using IGBTs Three-level voltage-fed inverters have recently become more and more popular for higher power drive applications because of their easy voltage sharing features. lower dv/dt per switching for each of the devices, and superiorharmonic quality at the output. The availability of NV-IGBTs has led to the design of a new range of medium-high voltage inverter using three-level NPC topology. This kind of inverter can realize a whole range with a voltage rating from 2. 3 kV to 4. 16kV Series connection of IIV-IGBT modules is used in the 3. 3 kV and 4. 1 6kV devices. The 2. 3 kV inverters need only one HV-IGBT per switch2,3. 2. 1 Power section To meet the demands for medium voltage applications. a three-level neutral point clamped inverter realizes the power section. In comparison to a two-level inverter. the NPC inverter offers the benefit that three voltage levels can be supplied to the output terminals, so for the same output current quality, only 1/4 of the switching frequency is necessary. Moreover the voltage ratings of the switches in NPC inverter topology will be reduced to 1/2. and the additional transient voltage stress on themotor 14 can also be reduced to 1/2 compared to that of a two-level inverter.The switching states of a three-level inverter are summarized in Table 1. U. V and W denote each of the three phases respectively; P N and 0 are the do bus points. The phase U, for example, is in state P (positive bus voltage)when the 井冈山大学外文翻译 5 switches S1uand S2u are closed, whereas it is in state N (negative bus voltage) when the switches S3u and S4u, are closed. At neutral point clamping, the phase is in 0 state when either S2u.or S3u, conducts depending on positive or negative phase current polarity, respectively. For neutral point voltage balancing, the average current injected at 0 should be zero. 2. 2 Line side converter For standard applications. a 12-pulse diode rectifier feeds the divided DC-link capacitor. This topology introduces low harmonics on. the line side. For even higher requirements a 24-pulse diode rectifier can be used as an input converter. For more advanced applications where regeneration. capability is necessary, an active front. end converter can replace the diode rectifier, using the same structure as the inverter. 2. 3 Inverter control Motor Control. Motor control of induction machinesis realized by using a rotor flux. oriented vector controller. Fig. 2 shows the block diagram of indirect vector controlled drive that incorporates both constant torque and high speed field-weakening regions where the PW M modulator was used. In this figure, the command flux.is generated as function of speed. The feedback speed is added with the feed 15 forward slip command signal,the resulting frequency signal is integrated and then the unit vector signals(cose and sin e)are generated. The vector rotator generates the voltage Vs and Angle e commands for the PW M as shown. PWM Modulator. The demanded voltage vector is generated using an elaborate PWM modulator. The modulator extends the concepts of space-vector modulation to the three-level inverter. The operation can be explained by starting from a regularly sampled sine-triangle comparison from two-level inverter. Instead of using one set of reference waveforms and one triangle defining the switching frequency, three-level Modulator uses two sets of reference waveforms Uand U and just one triangle. Thus, each switching transition is used in an optimal way so that several objectives are reached at the same time. Very low harmonics are generated. The switching frequency is low and thusswitching losses are minimized. A in a two-level inverter, a zero-sequencecomponent can be added to each set of reference waveform s in order to maximize the fundamental voltage component. As an additional degree of freedom, the position of the reference waveform s within the triangle can be changed. This can be used for current balance in the two halves of the DC-link. 3 Testing results After Successful installation of three 750 kW /2. 3 kV three-level inverters for one 2. 7 km long belt conveyor driving system in Cheng zhuang Mine. The performance of the whole VFC system was tested. Fig. 3 is 16 taken from the test, which shows the excellent characteristic of the belt conveyor driving system with VFC controller. Fig. 3 includes four curves. The curve 1 shows the belt tension . From the curve it can be find that the fluctuation range of the belt tension is very small. Curve 2 and curve 3 indicate current and torque separately. Curve 4 shows the velocity of the controlled belt. The belt velocity have the s shape characteristic. All the results of the test show a very satisfied characteristic for belt driving system. 4 Conclusions Advances in conveyor drive control technology in recent years have resulted in many more 井冈山大学外文翻译 6 reliable. Cost-effective and performance-driven conveyor drive system choices for users.Among these choices,theVariable frequency control (VFC) method shows promising use in the future for long distance belt conveyor drives due to its excellent performances. The NPC three-level inverter using high voltage TGBTs make the Variable frequency control in medium voltage applications become much more simple because the inverter itself can provide the medium voltage needed at the motor terminals, thus eliminating the step-up transformer in most applications in the past. The testing results taken from the VFC control system with NTC three. level inverters used in a 2. 7 km long belt conveyor drives in Chengzhuang Mine indicates that the performance of NPC three-level inverter using HV-TGBTs together with the control strategy of rotor field-oriented vector control for induction motor drive is excellent for belt conveyor driving system. References: 1Kung, Walter, “The Henderson Coarse Ore Conveying System-A Review of Commissioning, Start-up, and Operation”, Bulk Material Handling by Belt Conveyor 5, Society for Mining, Metallurgy and Exploration, Inc., 2004 ; 2Alspaugh, Mark, “The Evolution of Intermediate Driven Belt Conveyor Technology”, Bulk Solids Handling”, Vol. 23 (2003) No.3; 3Goodnough, Ryne, “In-Pit Conveying at the Wyodak Mine- Gillette, Wyoming” , Bulk Material Handling by Belt Conveyor 5, Society for Mining, Metallurgy and Exploration, Inc., 2004 ; 4Dewicki, Grzegorz, “Bulk Material Handling and Processing- Numerical Techniques and Simulation of Granular Material”, Bulk Solids Handling”, Vol. 23 (2003) No.2. 井冈山大学外文翻译 7 摘要 粒状 材料运输要求带式输送机具有更远的输送距离、更复杂的输送路线和更大的输送量。为了适应社会的发展,输送机需要在系统设计、系统分析、数值仿真领域更高层次发展。传统水平曲线和现代中间驱动的应用改变和扩大了带式输送机发展的可能性。本文回顾了为保证输送机的可靠性和可用性而运用数字工具的一些复杂带式输送机。 带式输送机及其牵引系统 在运送大量的物料时,带式输送机在
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 《人工智能导论》课程教学大纲
- 《西方政治制度史》课程教学大纲
- 2024年出售山地泥土合同范本
- 2024年代理记账合作协议书模板范本二人
- 2024年承接索道工程合同范本
- 保险代理公司反洗钱培训
- 喉癌解剖及手术配合
- 2024年谷物生产项目评价分析报告
- 2024至2030年中国牛油水果条数据监测研究报告
- 2024至2030年中国鳍片式省煤器数据监测研究报告
- DB50-T 771-2017 地下管线探测技术规范
- 2024年全国普法知识考试题库与答案
- 教学计划(教案)-2024-2025学年人教版(2024)美术一年级上册
- 2024年全国职业院校技能大赛中职组(婴幼儿保育赛项)考试题库-下(多选、判断题)
- 机械工程导论-基于智能制造(第2版)第3章 机械设计与现代设计方法
- 2024年新高考Ⅰ卷、Ⅱ卷、甲卷诗歌鉴赏试题讲评课件
- 任务二:诗歌朗诵教案 人教版
- 2024年福建省福州三牧中学中考三模英语试题(原卷版)
- DLT 572-2021 电力变压器运行规程
- DL∕T 1764-2017 电力用户有序用电价值评估技术导则
- 四年级上册英语教案-UNIT FOUR REVISION lesson 14 北京版
评论
0/150
提交评论