HMC-更换电源P570.docx_第1页
HMC-更换电源P570.docx_第2页
HMC-更换电源P570.docx_第3页
HMC-更换电源P570.docx_第4页
HMC-更换电源P570.docx_第5页
已阅读5页,还剩5页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

换P570电源步骤 (2011-10-12 11:47) 1.确定在P1-C6/C7位置没有以下设备,否则只能关机换电源,在线换电源不得超过5分钟FC 1800 - HSL-2 Ports - 2 CopperFC 1801 - HSL-2 Ports - 2 OpticalFC 1810 - GX Dual-port 4x HCA注:Remote I/O expansion card (FC 1800)Dual-port 4X Host Channel Adapter Infiniband card (FC 1810) 2. 如果P570是由HMC管理的,通过HMC(version6以下版本)删除设备,方法如下:a 在导航区,展开系统环境b 展开需要更换部件的管理系统c 展开Service Applicationsd 选择Service Focal Pointe 在内容部分,选择(Repair Serviceable Event)Install/Add/Remove Hardwaref 在Install/Add/Remove Hardware窗口,点击System Processor.g 从选择的菜单上,选择Remove FRU.h 在Installed enclosure types部分,选择system or expansion unit来删除部件i 在可用的FRU类型来选择插槽来删除部件j 点击Next,电源灯开始闪烁k 根据指令更换部件 3. 如何在AIX系统或者逻辑分区上定位坏的部件a 以root用户登录AIX系统b 输入diagc 从Function Selection菜单,选择Task Selection回车d 选择Display Previous Diagnostic Results回车e 从Display Previous Diagnostic Results返回界面上选择Display Diagnostic Log Summary,出现Display Diagnostic Log,返回内容包含按时间排序的一些事件列表f 注意T列表的最近的事件,选择后按回车g 选择Commit,将会详细显示此事件的信息h 记下事件的位置信息以及相应的SRN号i 退出到命令行下 4. 如果570不是通过HMC管理,更换设备方法如下:a 以root用户登录AIX系统b 输入diagc 从Function Selection菜单,选择Task Selection回车d 从Task Selection菜单上选择Identify and Attention Indicators回车e 从列表上选择故障部件后回车f 选择Commit,系统故障灯会点亮同时故障部件灯也被点亮(左边P1-E1,右边P1-E2)g 开始更换电源h 更换完成后,根据系统提示,退出到命令行下The FRU listed below is the most probable cause of the failure. If you have a replacement FRU on site you will be guied through an exchange procedure.FRU InformationLocation:U7879.001.DQDZMFT-E2You must determine if the repair can continue concurrently.Open the back door of the unit containing the FRU that is being repaired. To continue the repair concurrently,the following conditions must be true Another power supply must already be installed at location E1.This power supply has three LEDS. The LEDs must be set as follows:AC Input-on, not blinkingDC Output-on, not blinkingFault/Identify-offIf any of these conditions are not true, the repair can continue only after powering off the unit containing the FRU that is being repaired. If the unit is already powered off, you may proceed with a non-concurrent repair.Select Next to continue.Remove the power supplyNote:Two power supplies must be present in the system in order to power on the system unit.If one power supply fails,or you have a system failure that does not stop the fans,the system will continue to operate.You can remove and replace the power supply with the system power on if it is done in LESS THAN FIVE MINUTES After five minutes,the system will power down to prevent the system from over heating.1.Open the back rack door or cover.2.Disconnect the power cable from the backup of the power supply you are servicing.3.Pull the locking handle to pull the power supply out of the power supply byCAUTION: This part or unit is heavy,but has a weight smaller than 18 kilograms (39.7 pounds).Use care when lifting.removing,or installing this part or unit(c008).When you have completed these steps,click Next to continue.You must determine if the new power supply is operational. The new power supply is operational if its LEDs are set as follows: AC Input -on, not blinkingDC Output-on, not blinkingFault/Identify-blinking or offIf the LEDs are set differently, you must determine why. Make

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论