护士人员基本操作流程样本_第1页
护士人员基本操作流程样本_第2页
护士人员基本操作流程样本_第3页
护士人员基本操作流程样本_第4页
护士人员基本操作流程样本_第5页
已阅读5页,还剩23页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

目前文文件修改密码:8362839更多数据请访问精品数据网(.....)实施标准及国家注册证号:1、中国医疗器械注册证号:京药监械(准)字第2260379号2、中国医疗器械生产企业许可证号:京药监械生产许0098号3、医疗器械注册产品标准号:YZB/京0485-HY-D02●HY-D02●序号序号DD型“华医“华医”拼音缩写目录112699101113141515192124一、概述············································································二、仪器介绍·····································································三、仪器正面、后面及关键配件示意图·····························四、技术参数·····································································五、内存程序处方表··························································六、基础操作步骤图··························································七、操作方法详解······························································八、自动安全保护系统(详解)············································九、注意事项·····································································十、禁忌症·········································································十一、各类疾病临床症状介绍············································十二、吸水电极板放置穴位图············································十三、人体穴位参考图·······················································十四、故障和维修·······························································实施标准及注册证号·····················································见封面仪器装箱单、保修卡·····················································见封底请认真阅读本说明书后再操作仪器)一、概述:人体患了疾病,需要用打针、吃药等方法去诊疗。常言道“是药三分毒”,虽有夸张,却也一针见血地指出了“药品毒副作用对人体危害之大”是个不容忽略客观事实。认真分析,究其根本,不难发觉药品对人体毒副作用首先是由药品成份本身结构决定,其次来自我们给药方法,即人为造成。比如:利用口服给药,首先经过口腔胃肠壁吸收全身血液循环最终抵达患部。在这一药品漫长旅行路途中,经历了那么多不相干健康脏器,造成了一路“污染”和“浪费”,这种绝正确平均分配使真正需要对症药品患部得到却是微乎其微,真有点“少、慢、差、费”味道!尤其是对于长久困扰众多患者颈椎病、关节炎、骨质增生等骨关节病类疾病,其病因、病况虽各不相同,但正常活动范围受限、肢体麻木、肿胀,疼痛难忍,是这类疾病共有临床症状。中医理论讲“痛则不通,通则不痛”,而骨关节病引发疼痛、肿胀正是这一机理具体表现。它说明了血液循环是否通畅和疼痛是辩证因果关系。所以单纯地用激素类止疼药品舍本治标方法肯定是不可取。但那种较为普遍宣传用所谓良药或祖传秘方等药品去“化瘀”,其诊疗效果往往又不甚理想,这到底是为何呢?经广泛临床实践、辩证分析,其根本原因是:既然患部(比如膝关节骨质增生)已被确诊为“血瘀”(即患部及周围范围血液循环不通畅),那么用口服良药又怎样在患部血液循环不通畅(血瘀所致)前提下经过血液循环路径将药品直接送达患部去发挥治瘀功效呢?所以诊疗效果不甚理想是肯定结果。其实,骨关节病类患者患部实乃最需营养之处,也正是血液循环不通畅之处。能够说正是“血瘀”造成有效药品不能立即送至病灶,或说患部药品浓度较低是致使药力作用不能充足发挥其效力关键。总而言之:不难看出,诊疗骨关节类疾病,首先应为患部发明一个良好授药环境,使之通畅。并应和此同时,将足够浓度、剂量对症药品应用靶向给药导入法直接将药品送至患部,使病灶区在多方综合诊疗(即物理诊疗、药品诊疗、电流按摩、反射诊疗法等)攻击之下,促进其炎症消失、吸收水肿、减轻压力,致痛物质移除,从而消除致病原因,结束患部恶性循环状态,使患者疼痛症状显著减轻、活动受限范围缩小,在此基础上,发挥患者本身运动能力,调整身体免疫功效等方面主动原因,群起而攻之,进而使患部进入良性循环状态,真正取得事半功倍、立竿见影诊疗效果。二、HY-D02A型计算机中频药品导入诊疗仪(智慧移动单路)介绍1、疗效好是02A智能移动单路仪器特色之一:疗效好=动态诊疗+静态诊疗+三块温热移动吸水电极板本仪器含有了动态诊疗和静态诊疗相结合独特优点。所谓动态诊疗就是在诊疗过程中三块温热吸水电极板可左右随意移动,而且移动速度快慢可调;所谓静态诊疗就是一旦找到了致痛点或舒适点便可将诊疗点锁定,进行针对性定点诊疗,这种独特设计既可对病灶区进行局部诊疗,也可对病灶周围区域进行动态诊疗,真正做到捕捉病灶、靶向导药、靶向按摩,逐点逐面地消除炎症,活血化瘀,疏通经络,提升疗效。患者在使用中频类仪器诊疗时,常常埋怨地说:“这两块电极板怎么一块劲头大,另一块一点劲全部没有呀!”。更有患者会直截了当地说:“您这仪器怎么就只能诊疗一个点啊?我左肩、右肩及中间大椎一趟线全部疼,您能不能想措施给处理呢?”现在广大患者使用中频类仪器输出是由两块电极板组成一组电路输出,从设计上讲,这两块电极其中一块是主作用极(劲头大),而另一块是辅助极(劲头小),这么就只能照料一边病灶区(穴位点),顾此失彼。所以不管怎样不厌其烦地耐心地调整调换,其结果全部会无功而返。经调查,众多医生和患者全部迫切地期望中频类仪器厂家能设计生产出那种真正能满足患者诊疗需要,安全可靠,诊疗效果好且使用方便好仪器来。具体地说:期望这种新仪器设置含有多个诊疗点(不要只一个,最少2~3个)且每个诊疗点全部能够按诊疗要求进行单点诊疗或多点诊疗。假如再要求高一点,在诊疗要实现以上这些功效最关键一点,比如:自动寻点、吸水电极极板左右自由程序化移动等,均不需要患者手里拿着吸水电极板在患部一点一点地去寻求,去移动,而只是需要操作者轻按一下仪器上功效键便可全部自动完成,这么设计使逐点、逐线、逐面三维立体诊疗变成了现实,从而使疏通经络(经络通畅)、活血化瘀(瘀滞疏散)有放矢你使用了HY-D02A型计算机中频药品导入诊疗仪(智慧移动单路)就会真正体会到。2、确保安全是02A智能移动单路仪器特色之二:应用这类诊疗仪诊疗疾病,确保患者使用安全和确有疗效,是医生和患者首先关心,也是生产厂商必需做到。现在社会上流通本类诊疗仪,品种繁多,但均未设置输出断路自动安全保护系统。致使电击患者现象常常发生。比如:在诊疗时,让患者适应诊疗剂量必需是一点一点缓慢增加上去,而不是忽然跳到所需值。不过,在诊疗过程中正是因为患者挪动一下诊疗体位就有可能造成接处不良或诊疗线断线、电极板脱落等等,这全部能使输出断路即患者感觉不到诊疗动作。一旦忽然接上,会在瞬间剂量由零突增到最大,这突如其来大剂量,轻者使患者吓一跳(电击所致),重者会造成医疗事故。针对这种不安全现实状况,为了确保患者使用绝对安全。本仪器为此设置了独一无二自动安全保护系统。其设计原理是:应用计算机每时每刻地自动监测输出回路电流,一旦输出回路电流为零(输出断路),计算机会立即中止输出。待故障消除后仪器会自动缓慢恢复输出到设定安全剂量,然后依据病况需要再手动一点一点地增加到所需值。这么设计就有效地预防了输出剂量在瞬间内由最小突增到最大值,以致电击患者现象发生,从而确保患者使用仪器绝对安全。3、仪器机理在电场力作用下,把药品电解成离子状态,利用同性相斥,异性相吸特征,将药品离子引入人体内给药方法叫做药品离子导入法。这种方法自20世纪六十年代传入中国,因为受当初科技还不发达条件所限制,无法克服在药品导入过程中出现极化电场,致使药品导入极难进行。多年来,仍有些厂家采取这种过时、极不完善设备在给患者诊疗,但当中不乏有些厂家千方百计对此有所改善,但还存有很多缺点和弊端。就说现在市场上流通直流药品导入诊疗仪、低频诊疗仪、中频诊疗仪等各类仪器全部有各自独特诊疗功效,不过受其本身条件局限,又全部各自存在着很多缺点和弊端。简单地概括:中频双向电流含有显著降低人体阻抗并可进入人体较深病变部位,不易发生电解,还含有提升生物膜通透性、镇痛止疼及消炎作用。但不含有药品离子导入功效;低频电流含有显著兴奋刺激神经组织引发肌肉强烈收缩作用,还能够刺激内脏平滑肌并调整其张力,恢复内脏正常功效。但低频电流作用于人体时有疼痛感,人体不易接收,且不能进行药品离子导入;直流电流含有显著扩张血管、促进血液循环及有条件进行药品离子导入功效。但其易产生电解、作用于人体深度较浅等不足之处。真是尺有所短,寸有所长啊!鉴于上述各物理频段电流客观存在诊疗作用和弊端,所以说试图利用某单一频段就能治愈临床上复杂疾病是不现实。北京华医新技术研究所本着“临床实践是检验医疗仪器功效之唯一标准”标准,利用现代计算机技术,将中频仪、低频仪及药品导入仪三类仪器功效之精华巧妙地浓缩于一身,研制成功了新一代HY-D02A型计算机中频药品导入诊疗仪(智慧移动单路)。该仪器是把中国外医疗教授多年临床实践经验及一生心得提炼、组合成多种物理诊疗程序(即处方),使一系列不一样诊疗参数及物理波形在微电脑控制下组合输出。患者只需对症选择对应诊疗处方,患者便可取得教授等级诊疗。在诊疗过程中,患部同时接收了中频、低频、直流等仪器及对症药品综合诊疗功效。且上述多种功效不是简单迭加关系,而是相互协同、相互促进,起到推波助澜作用,患者可享受到针灸和人工手法按摩所不及多种揉捏、推拿、敲击、按压、拍打、震颤等无法言表电流按摩动作。最大程度地发挥其独特综合诊疗功效。本仪器综上述多种功效之大成集中作用于病灶,其功效是引发机体所需要回复性反应,消除病因及病理过程,恢复被破坏了生理平衡,唤起和增强机体防御系统,并发明良好授药环境,从而借助药品药理功效而达成治病和防病目标。经临床实践证实:本仪器诊疗效果显著、见效快,尤其是消炎、止疼可谓立竿见影。含有应用范围广、操作简单方便、安全可靠、无针、无痛、无毒副作用,经济实用。深受医院及广大患者好评,值得更深入推广使用。三、仪器正面、后面及关键配件示意图仪器正面示意图HY-D02A型计算机中频药品导入诊疗仪(智慧移动单路)一、颈椎病1、HY-D02A型计算机中频药品导入诊疗仪(智慧移动单路)一、颈椎病1、颈椎骨质增生2、颈椎椎间盘突出3、颈部僵硬手指麻木4、韧带粘连、肿痛腰椎间盘突出11、膝关节骨性关节炎12、13、关节腔积液、肿胀14、15、16、软组织损伤5、6、腰椎骨质增生7、腰疼、腰肌劳损8、腰椎椎管狭窄9、10、坐骨神经痛处方表1三、二、膝关节骨1三、二、膝关节骨性关节炎62435华医诊疗仪62435华医诊疗仪MK北京华医新技术研究所MK北京华医新技术研究所1415QSSN1415QSSN开/关切换降低增加选择开/关切换降低增加选择97812131110978121311109.处方、时间、剂量降低键9.处方、时间、剂量降低键10.“手动”、“自动”切换键11.开/关键向A1方向移动键A1、A0、A2三点之间运动速度加紧键向A2方向移动键A1、A0、A2三点之间运动速度减缓键14.“手动”指示灯15.“自动”指示灯注释说明:1.诊疗处方表2.液晶显示器3.“中频”方法指示灯4.“导入”方法指示灯5.“诊疗”状态指示灯6.“保护”状态指示灯7.处方、时间选择键8.处方、时间、剂量增加键1212、1313、仪器后面示意图A1A1A0A2遥控1A开关加热导入1234567注释说明:1.诊疗线黑色六芯插头插孔2.诊疗线红色六芯插头插孔3.诊疗线白色六芯插头插孔4.遥控器灰色五芯插头插孔5.加热/常温功效开关6.导入/中频功效开关7.1A保险座8.电源开关中频常温中频常温关键配件示意图A2A0AA2A0A1A1A0A2遥控器增加降低吸水电极板吸水电极板897654321诊疗线三端诊疗线897654321诊疗线三端诊疗线注释说明:1.诊疗线黑色六芯插头注释说明:1.诊疗线黑色六芯插头2.诊疗线红色六芯插头3.诊疗线白色六芯插头4.诊疗线黑色三端插头5.诊疗线红色三端插头5.诊疗线红色三端插头6.诊疗线白色三端插头7.检机负载黑色六芯插头10.遥控器灰色五芯插头11.遥控器操作面板检机负载遥控器四、技术参数:1、电源电压:220V50HZ功率:15W2、内存处方:16个调幅度:100%3、输出方法:①计算机中频(双向)②药品导入(单向)③加热(温热输出)④常温(不加热)⑤手动方法⑥自动方法4、输出波形:矩形波、三角波、指数波、棱形波、阶梯波、正弦波、锯齿波、积分波、微分波等。5、仪器外型尺寸:300×245×70mm净重:Kg6、外包装尺寸:350×290×110mm毛重:Kg五、内存程序处方表:123456789101112131415、风湿、类风湿性关节炎16、软组织损伤液晶显示处方北京华医新技术研究所0120:液晶显示处方北京华医新技术研究所0120:00调整三块电极板作用人体作用点A0、A1、A2之间相互转换速度,即减缓三点之间运动速度。►键◄K键锁定A0-A2和A0-A1两点之间诊疗,真正达成病痛部位对症诊疗效果。1.打开电源开关1.打开电源开关拨动后背板上中频拨动后背板上中频/导入开关,向下至“中频”方法,“中频”绿色灯点亮,向上至“导入”方法,“导入”绿色灯点亮。2.按动按动N键诊疗处方“01”闪动,等候选择,本机设置16个诊疗处方。3.按动△按动△键或▽键选择“01处方~16处方”之间对应诊疗处方。4.再次按动N再次按动N键诊疗时间“20”闪动,等候调整。“20”为机内预置优选时间。5.调整改疗时间。本机设置诊疗时间范围为1~40min。6.处方和时间选择完成,将输出诊疗线三色六芯插头分别插入仪器后背输出插孔上,即黑色插头插入处方和时间选择完成,将输出诊疗线三色六芯插头分别插入仪器后背输出插孔上,即黑色插头插入A1插孔,红色插头插入A0插孔,白色插头插入A2插孔。(注意插头上分别印有“”字样,插入时面向仪器后背板,将此箭头对准插孔插槽并插入,且插实插牢。同时将诊疗线另外三色三端金属插头分别插入吸水电极板对应插孔内。若选择“中频”方法,将吸水电极板吸水面用温水浸湿浸透,挤去多出水分,再用绑带将其固定在诊疗部位;若选择“导入”方法,将吸水电极板吸水面用温用浸湿浸透,挤去多出水分,并在吸水电极板吸水面上或诊疗部位皮肤上涂上将被导入药液,吸水面紧贴在需要诊疗部位,再用绑带将其固定。注意:做导入诊疗时,切勿将吸水电极板吸水面摘下。7.7.拨动后背板上常温/加热开关,向下至拨动后背板上常温/加热开关,向下至“常温”状态,即吸水电极板无热输出,向上至“加热”状态,即吸水电极板有热输出。状态,即有8.“诊疗“诊疗”绿色灯点亮,同时“手动”绿色灯点亮,对应诊疗处方改为剂量“00”并闪动,等候调整。9.10.11.11.12.12.13.14.14.调整三块吸水电极板作用人体作用点A0、A1、A2之间相互转换速度,即加紧三点之间运动速度。调整三块吸水电极板作用人体作用点A0、调整三块吸水电极板作用人体作用点A0、A1、A2之间相互转换速度,即减缓三点之间运动速度。15.16.七、操作方法详述:2、处方选择:按动选择(N)键,处方“01”闪动,表示诊疗处方等候调整。此时按动增加()键或降低()键,可在01处方~16处方之间任意选择。3、时间选择:再次按动选择(N)键,处方闪动停止。时间“20”开始闪动,表示诊疗时间等候调整。此时按动增加()键或降低()键,调整改疗时间,本机设置诊疗时间范围为:1~40分钟。4、5、67、上述准备工作检验无误后,按动开/关(S)键,诊疗绿色指示灯点亮,“手动”绿色指示灯点亮,处方停止显示,剂量“00”闪动,秒点开始倒计时,表示此次诊疗开始,按动增加()键,剂量“00”停止闪动,剂量数值(表示作用力大小)依次增加,患者可依据病况需要按动增加()键或降低()键,直至所需剂量。本仪器设置剂量范围00~85。8、本机在“手动”诊疗中设计了定点转移功效,按动开/关(S)键后,A0号极板(红色插头)和A1号极板(黑色插头)形成诊疗回路,若您需要转移诊疗点,则按动◄K(A2/快)键,诊疗点会由A0-A1向A0-A2方向进行转移,在转移过程中“手动”绿色灯处于闪动状态,当闪动停止,表示作用点根本转移。若您需要再次转移诊疗点,则按动M►(A1/慢)键,则由A0-A2向A0-A1方向进行转移。9、按动切换(Q)键,“手动”诊疗方法立即转为“自动”诊疗方法,“手动”绿色灯灭,“自动”黄色灯点亮,三块吸水电极板作用人体作用点A1、A0、A2之间自动程序移动,由点到面形成立体围绕诊疗。若您需要加紧三点之间运动速度,按动◄K(A2/快)键,“自动”黄色灯处于闪动状态,当闪动停止,表示三点之间运动速度加紧至极点;若您需要减缓三点之间运动速度,按动M►(A1/慢)键,“自动”黄色灯处于闪动状态,当闪动停止,表示三点之间运动速度减缓至极点。在三块吸水电极板作用人体作用点自动程序移动过程中,若您需要锁定两点之间定点诊疗,则再次按动切换(Q)键,“自动”黄色灯灭,“手动”绿色灯点亮,“自动”程序移动转为“手动”定点诊疗,此时患者能够真正体会到病痛部位对症诊疗效果。10、在诊疗过程中,处方立即间均不得修改,其增加()键和降低()键只起剂量加减修改作用,切换(Q)键切换“手动”和“自动”功效。12、诊疗完成,仪器自动报警停机,显示系统恢复诊疗前状态。患者松开绑带,取下电极板后关闭电源开关并拔掉插头即可。八、自动安全保护系统:(详解)九、注意事项:1、开启电源开关后再在诊疗部位上放吸水电极板,取下吸水电极板后再关电源开关。2、使用导入方法诊疗时,切勿将吸水电极板吸水面摘下。6、吸水电极板放置位置通常在病变部位穴位点、阿是穴(疼痛点)、肌肉两端(尤其是小腿肌肉)或遵医嘱放置。8、液晶显示混乱,关机后重新开启即可消除。9、诊疗输出剂量大小以适中为好,不要一味追求过大。10、高频仪器(如:微波、超短波)对本仪器含有干扰影响。不要和本仪器放在同一房间内使用。11、夏季使用本仪器通常连续工作时间不超出4小时。不诊疗时关掉电源开关,拔掉电源插头。十、禁忌症出血倾向、活动性肺结核、破伤风、肿瘤、妊娠、精神病及心力衰竭、装有心脏起博器及不适应电刺激诊疗患者均严禁使用本仪器诊疗。心脏及心脏投影区,太阳穴及孕妇下腹部均不得作为诊疗部位。十一、各类疾病临床症状介绍:1、颈椎病颈椎病又称颈椎综合症,是中老年人常见多发病,亦为临床疑难病。其发病原因是在颈椎间盘退行改变(即:骨质增生)基础上,受应力(包含急性损伤、慢性劳损压力和张力)作用,发生椎体及其附件骨质增生和肌肉、肌腱、韧带、关节囊等软组织病理改变,引发颈神经根、颈段脊髓、椎动脉、颈交感神经等受刺激和压迫,以至发生损伤及继发性改变,出现一系列复杂临床症状。颈椎病病理过程是因颈椎间盘退行性改变(骨质增生),而致后关节囊及钩椎关节松弛,其通透性逐步降低,造成髓核逐步脱水,以致纤维化,椎间盘厚度减小、变窄,关节腔减小,造成水肿、无菌性炎变。其临床表现差异较大,常见有头、颈、肩、背及上肢顽固性定位疼痛和麻木,睡眠、低头劳动或颈部活动时症状加重;绝大部分患者椎旁有压痛并可摸到硬结;头颈上肢活动受限;咽喉有异物感、胸膈闷痛等症状。有部分患者以连续性颈臂痛呈阵发性加剧为主。患侧上肢可出现显著根性症状,如手指疼痛、麻木、无力、肌肉萎缩等症状。当咳嗽、深呼吸时,均可诱发患肢症状阵发性加剧。应用本仪器处方“一”诊疗可减轻神经根刺激和压迫,消除神经根炎性水肿,改善脊髓血供营养。延缓或减轻椎体及关节囊、韧带钙化、骨化过程,减轻根部粘连,加强对症镇痛止疼、消除关节炎症、软化斑痕、松懈粘连,使患者疼痛、麻木等症状减轻。诊疗方法:可选择中频或导入法中小剂量诊疗。药品可选择奴佛卡因、碘化钾、陈醋、冰醋酸、威灵仙、草乌等。每日一次,每次20分钟,一疗程为20次。2、腰椎间盘突出人腰椎有五节,节和节之间全部有个类似软垫样圆盘状结构称为椎间盘。椎间盘基础无血液供给,腰椎间盘通常在20岁就开始发生退行性改变,椎间盘退变及腰部劳损,可造成椎体骨质增生改变,甚至形成骨刺,发生椎体不稳。伴随年纪增加,当增生骨刺妨碍了关节功效或刺激周围软组织时,则产生局部疼痛、麻木、发凉、运动不灵活或僵硬感,而疼痛有时可呈放射性。腰椎增生时,腰痛显著。腰椎间盘突出症发生原因是在椎间盘退行性改变基础上伴有外伤,周围韧带松弛是椎间盘突出内因。而外伤、劳损引发纤维环破裂,髓核突出,压迫脊髓神经根,产生充血、水肿、粘连等形成无菌性炎症,从而引发腰腿痛。其临床关键表现多为一侧腰痛,一侧腿后外侧串痛或麻木感(沿坐骨神经行径)。而中央型则为双下肢麻痛,咳嗽、喷嚏、大便用力时腿痛加重。腰椎有轻重不一样侧弯,下腰部正常生理凹陷消失,患侧下腰部棘突旁1~2厘米处有压痛,并向患肢放射,直腿抬高试验阳性。应用本仪器处方“二”诊疗,可显著促进局部血液循环、疏通瘀滞、打通痹阻血脉,可开启退变细胞,使其恢复正常功效,可改善纤维环周围血液循环,缓解肌肉痉挛和疼痛,消除炎症、吸收水肿,降低增生骨质周围软组织慢性渗出。消除因腰间盘突出、骨质增生引发根性坐骨神经痛。增强腰部肌肉、韧带支持能力,减轻疼痛。促进突出椎间盘组织还纳及突出髓核复位,促进椎间盘纤维环破裂处形成“纤维包裹”加强对“损伤微弱处”固定,从而发挥诊疗作用。辅以中、西药内服,使药效殊途同归,其效更佳。诊疗方法:使用“中频”方法,诊疗点采取痛点或神经干部位,两吸水电极板可并置于腰部疼痛部位。(腰椎间盘突出者诊疗剂量偏小为佳,腰肌劳损及腰疼等患者诊疗剂量适中。)若选择“导入”方法,药品可用碘化钾(负极)或陈醋(负极)。如有神经根粘连者,可选择碘化钾(负极)或在腰部用10%硫酸镁(正极)进行“导入”诊疗。每日1~2次,每次20分钟,20次为一疗程。3、膝关节骨性关节炎膝关节是骨性关节炎好发部位。和髋关节等其它部位骨关节炎一样,膝关节骨关节炎也分原发性和继发性两种。原发性骨关节炎也就是老年性骨关节炎,多见于老年,尤其是老年妇女。继发性骨关节炎则往往是因为全身性疾病和膝关节急性创伤、慢性劳损所致。慢性劳损原因中以肥胖较为常见。肥胖者因躯体重量较大,使膝关节应力超荷,加速了膝关节软骨磨损破坏,从而造成膝关节骨关节炎。膝关节骨关节炎病理改变关键表现在软骨软化,弹性消失,软骨基质丧失硫酸软骨素,胶原纤维暴露,软骨面变得粗糙、碎裂,软骨下新骨形成。在骨端边缘,尤其是在不负重区有骨赘形成,滑液也可被挤入骨内形成囊肿。滑膜摄取变性软骨碎片造成绒毛肥大,关节囊纤维化并挛缩,在早期和急性炎症期可相关节腔积液。因为膝关节骨关节炎上述病理改变,尤其是关节磨损,滑膜炎症及关节周围韧带变性,炎症等病理改变造成临床上出现疼痛,关节僵硬,肿胀,活动受限,肌肉萎缩和关节畸形等一系列症状和体征。比如:疼痛症状往往是炎性改变,关节囊挛缩,骨充血等改变所致;肿胀则是滑膜炎症渗液反应;僵硬和活动受限和关节囊纤维化骨赘,关节面碎片或游离体嵌入相关。常因老年组织变性及长久劳损引发骨质增生;暴力或强大肌肉忽然收缩引发骨折;关节滑膜受化脓性细菌感染引发化脓性关节炎;外伤、风湿、痛风、感染引发滑囊炎;因跖腱膜及足短肌在其附着处产生新骨引发跟刺等。膝关节骨关节炎诊疗除了疼痛症状十分严重,非手术诊疗无效,关节畸形影响功效,关节内游离体有交锁等需要手术诊疗外,通常以非手术诊疗为主。应用本仪器处方“三”中频法诊疗,可控制感染发展、消除炎症、肿胀、解除肌肉痉挛,而达成镇痛止疼作用。对膝、踝关节,扭伤、挫伤等造成软组织损伤及周围神经损伤有良好诊疗作用。对风湿、类风湿患者膝关节炎有消炎消肿、镇痛止疼作用,可降低关节活动受限范围,提升骨关节病患者生活质量。对这类患

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论