版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
ICS27.140
P59
ENERGYSECTORSTANDARD
OFTHEPEOPLE’SREPUBLICOFCHINA
中华人民共和国能源行业标准
PNB/T10144-2019
TechnicalSpecificationforFlowMonitoringandMeasuringof
Hydraulic-MechanicalAuxiliarySysteminHydroelectricPowerPlants
水力发电厂水力机械辅助系统流量监视测量技术规程
IssuedonJune4,2019ImplementedonOctober1,2019
IssuedbyNationalEnergyAdministrationofthePeople’sRepublicofChina
Introduction
ThisEnglishversionisoneofChina’senergysectorstandardseriesinEnglish.Itstranslation
wasorganizedbyChinaRenewableEnergyEngineeringInstituteauthorizedbyNational
EnergyAdministrationofthePeople’sRepublicofChinaincompliancewithrelevant
proceduresandstipulations.ThisEnglishversionwasissuedbyNationalEnergy
AdministrationofthePeople’sRepublicofChinainAnnouncement[202x]No.xdatedxxxx,
202x.
ThisversionwastranslatedfromtheChineseStandardNB/T10144-2019,Technical
SpecificationforFlowMonitoringandMeasuringofHydraulic-MechanicalAuxiliarySystem
inHydroelectricPowerPlants,publishedbyChinaWater&PowerPress.Thecopyrightis
reservedbyNationalEnergyAdministrationofthePeople’sRepublicofChina.Intheevent
ofanydiscrepancyintheimplementation,theChineseversionshallprevail.
Manythanksgotothestafffromtherelevantstandarddevelopmentorganizationsandthose
whohaveprovidedgenerousassistanceinthetranslationandreviewprocess.
ForfurtherimprovementoftheEnglishversion,anycommentsandsuggestionsarewelcome
andshouldbeaddressedto:
ChinaRenewableEnergyEngineeringInstitute
No.2Beixiaojie,Liupukang,XichengDistrict,Beijing100120,China
Website:
Translatingorganizations:
POWERCHINABeijingEngineeringCorporationLimited
ChinaRenewableEnergyEngineeringInstitute
Translatingstaff:
Reviewpanelmembers:
NationalEnergyAdministrationofthePeople’sRepublicofChina
I
翻译出版说明
本译本为国家能源局委托水电水利规划设计总院按照有关程序和规定,统一组织翻
译的能源行业标准英文版系列译本之一。202x年x月x日,国家能源局以202x年第x
号公告予以公布。
本译本是根据中国水利水电出版社出版的《水力发电厂水力机械辅助系统流量监视
测量技术规程》NB/T10144—2019翻译的,著作权归国家能源局所有。在使用过程中,
如出现异议,以中文版为准。
本译本在翻译和审核过程中,本标准编制单位及编制组有关成员给予了积极协助。
为不断提高本译本的质量,欢迎使用者提出意见和建议,并反馈给水电水利规划设
计总院。
地址:北京市西城区六铺炕北小街2号
邮编:100120
网址:
本译本翻译单位:中国电建集团北京勘测设计研究院有限公司
本译本翻译人员:
本译本审核人员:
国家能源局
II
AnnouncementofNationalEnergyAdministration
ofthePeople’sRepublicofChina
[2019]No.4
NationalEnergyAdministrationofthePeople’sRepublicofChinahasapprovedandissued
297sectorstandardssuchasCodeforElectricalDesignofPhotovoltaicPowerProjects,
including105energystandards(NB),168electricpowerstandards(DL),and24
petrochemicalstandards(NB/SH).
Attachment:DirectoryofSectorStandards
NationalEnergyAdministrationofthePeople’sRepublicofChina
June4,2019
Attachment:
DirectoryofSectorStandards
Adopted
SerialReplacedApproval
StandardNo.TitleinternationalImplementationdate
numberstandardNo.date
standardNo.
…
TechnicalSpecification
forFlowMonitoringand
Measuringof
NB/T
17Hydraulic-Mechanical2019-06-042019-10-01
10144-2019
AuxiliarySystemin
HydroelectricPower
Plants
…
III
Foreword
AccordingtotherequirementsofDocumentGNKJ[2015]No.12issuedbyNationalEnergy
AdministrationofthePeople’sRepublicofChina,“NoticeonReleasingtheDevelopmentand
RevisionPlanoftheSecondBatchofEnergySectorStandardsin2014”,andafterextensive
investigationandresearch,summarizationofpracticalexperience,consultationofrelevant
Chinesestandards,andwidesolicitationofopinions,thedraftinggrouphaspreparedthis
specification.
Themaintechnicalcontentsofthisspecificationinclude:generalrequirementsofflow
monitoringandmeasuring,selectionofmonitoringpoints,selectionofflowcomponents,and
layoutandinstallationrequirementsofpipes.
NationalEnergyAdministrationofthePeople’sRepublicofChinaisinchargeofthe
administrationofthisspecification.ChinaRenewableEnergyEngineeringInstitutehas
proposedthisspecificationandisresponsibleforitsroutinemanagement.EnergySector
StandardizationTechnicalCommitteeonHydropowerHydraulicMachineryisresponsiblefor
theexplanationofspecifictechnicalcontents.Commentsandsuggestionsinthe
implementationofthisspecificationshouldbeaddressedto:
ChinaRenewableEnergyEngineeringInstitute
No.2Beixiaojie,Liupukang,XichengDistrict,Beijing100120,China
Chiefdevelopmentorganization:
POWERCHINABeijingEngineeringCorporationLimited
Participatingdevelopmentorganizations:
BeijingWanruidaMonitoringTechnologyCo.
ChinaThreeGorgesCorporation
Chiefdraftingstaff:
GOUDongmingYIZhongyouZHOUZhenzhongZHENGDongfei
LIUWanjingLIWenxueLIShihongWANGYuhui
GUOXibingZHANGHaoshengZHURushaHUANGYu
LIUGongmeiYAOZengmin
Reviewpanelmembers:
DAIKangjunYOUChaoYUANLianjunFUGuofeng
ZHANGQiangJIANGDengyunLIYuebinWUSaibo
WANGJianhuaCHENDongYANGJiamingQINDaqing
SHAOBao’anPENGShuojunDUGang
IV
Contents
1GeneralProvisions.................................................................................................................................1
2Terms.......................................................................................................................................................2
3GeneralRequirementsofFlowMonitoringandMeasuring..............................................................3
4SelectionofMonitoringPoints..............................................................................................................5
5SelectionofFlowComponents..............................................................................................................7
6LayoutandInstallationRequirementsofPines..................................................................................9
ExplanationofWordinginThisSpecification........................................................................................10
ListofQuotedStandards...........................................................................................................................11
V
1GeneralProvisions
1.0.1Thisspecificationisformulatedwithaviewtostandardizingtheflowmonitoringand
measuringofhydraulic-mechanicalauxiliarysysteminhydroelectricpowerplants,toimprovethe
levelofsafeandeconomicoperation.
1.0.2Thisspecificationisapplicabletotheflowmonitoringandmeasuringof
hydraulic-mechanicalauxiliarysysteminhydroelectricpowerplants.
1.0.3Theflowmonitoringandmeasuringofhydraulic-mechanicalauxiliarysystemin
small-sizedhydroelectricpowerplantsmaybesimplifiedonthebasisofthisspecification.
1.0.4Thisspecificationspecifiesthegeneralrequirements,selectionofmonitoringpoints,
selectionofflowcomponents,andlayoutandinstallationrequirementsofpipesforflow
monitoringandmeasuringofhydraulic-mechanicalauxiliarysysteminhydroelectricpower
plants.
1.0.5Inadditiontothisspecification,theflowmonitoringandmeasuringof
hydraulic-mechanicalauxiliarysysteminhydroelectricpowerplantshallcomplywithother
currentrelevantstandardsofChina.
1
2Terms
2.0.1flowcomponents
flowmonitoringandmeasuringdevicesuchasflowmeterorflowswitch
2.0.2flowmeter
deviceformonitoringthefluidflowvaluewithinthepipe.Theflowmeterscanbeclassifiedinto
electromagneticflowmeter,ultrasonicflowmeter,mechanicalflowmeter,differentialpressure
flowmeter,etc.dependingonthemeasuringmode;andcanbeclassifiedintoplug-inflowmeter,
flange-connectedflowmeter,etc.dependingontheinstallationmode
2.0.3flowswitch
componentformonitoringtheflowvalueandcomparingwithsetvalue,whichcanoutputsignals
whentheflowishigherorlowerthanacertainsetvalue.Flowswitchcanbeclassifiedinto
thermalflowswitch,mechanicalflowswitch,etc.
2
3GeneralRequirementsofFlowMonitoringandMeasuring
3.0.1Thefunctionsofmonitoringandmeasuringofeachpartshallmeetthefollowing
requirements:
1Theflowcomponentsshallbemountedinthecoolingwatermainoutletpipesfor
turbine-generatorunitandmaintransformerrespectively,whichshallmonitortheflowof
thepointandoutputtheanalogsignalordigitalsignal.
2Theflowcomponentsshouldbemountedatpumpoutlet,whichoutputtheswitching
signal,switchingplusanalogsignals,orswitchingplusdigitalsignals.
3Theflowcomponentsshallbemountedincooleroutletpipeandmainfirefightingpipe,
whichoutputtheswitchingsignal,switchingplusanalogsignals,orswitchingplusdigital
signals.
4Theflowcomponentsshallbemountedinthewatersupplypipesformainshaftsealand
labyrinthring,whichoutputtheswitchingsignal,switchingplusanalogsignals,or
switchingplusdigitalsignals.
5Theflowcomponentsshallbemountedinthewatersupplypipeforequipmentlubrication,
whichoutputtheswitchingsignal,switchingplusanalogsignals,orswitchingplusdigital
signals.
6Theflowcomponentsshallbemountedintheoilpipeforexternalcirculationsystem,
whichoutputtheswitchingsignal,switchingplusanalogsignals,orswitchingplusdigital
signals.
3.0.2Thealarmvalueandshutdownvalueofflowmonitoringandmeasuringshouldmeetthe
followingrequirements:
1Thelowalarmvalueofwaterflowineachcooleroutletpipeshouldbedeterminedby
equipmentmanufacturer,andshouldnotbelessthan70%ofthedesignflowifnot
specifiedbythemanufacturer.
2Thelowalarmvalueofwaterflowatpumpoutletpipeshouldnotbelessthan70%ofthe
designflow.
3Thelowalarmvalueandshutdownvalueofoilpipeinbearinglubricationpipefor
tubularunitshouldbedeterminedbyequipmentmanufacturer,Ifnotspecifiedbythe
manufacturer,thelowalarmvalueshouldnotbelessthan70%ofthedesignvalueand
theshutdownvalueshouldnotbelessthan50%ofthedesignvalue.
4Thelowalarmvalueandshutdownvalueofwatersupplyflowformainshaftsealshould
bedeterminedbyequipmentmanufacturer.Ifnotspecifiedbythemanufacturer,thelow
alarmvalueshouldnotbelessthan70%ofthedesignvalue,andtheshutdownvalue
shouldnotbelessthan50%ofthedesignvalue.
3.0.3Theswitchingsignal,analogsignalordigitalsignaloutputtedbyflowcomponentsshall
3
meettherequirementsofdataacquisitionbymonitoringandcontrolsystem.
3.0.4Theenvironmentinwhichtheflowcomponentsrunforlong-termshallcomplywiththe
currentsectorstandardDL/T1107,BasicSpecificationsofAutomaticComponentsfor
HydropowerPlant.
4
4SelectionofMonitoringPoints
4.0.1Theconfigurationofflowmonitoringpointsforunitauxiliarysystemshouldbein
accordancewithTable4.0.1.
Table4.0.1Configurationofflowmonitoringpointsforunitauxiliarysystem
Numberof
No.PositionFlowcomponent
monitoringpoints
CoolingwatermainoutletpipeforunitcoolingElectromagnetic
11
watersystemflowmeter
2Coolingwatersupplypipeformainshaftseal1Flowmeter
3Coolingwatermainoutletpipeforaircoolers1Flowswitch
Coolingwateroutletpipeforthrust-bearing
41Flowswitch
coolers
Coolingwateroutletpipeforupper-guide
51Flowswitch
bearingcoolers
Coolingwateroutletpipeforlower-guide
61Flowswitch
bearingcoolers
Coolingwateroutletpipeforturbineguide-
71Flowswitch
bearingcoolers
Coolingwatersupplypipeforupperlabyrinth
81Flowswitch
ring
Coolingwatersupplypipeforlowerlabyrinth
91Flowswitch
ring
Lubricationoilinletpipeforgeneratorguide
101Mechanicalflowmeter
bearingoftubularunit
Lubricationoilinletpipeforturbineguide
111Mechanicalflowmeter
bearingoftubularunit
Lubricationoilinletpipefortwo-direction
121Mechanicalflowmeter
thrustbearingoftubularunit
Outletpipeofexternalcirculationcoolersuchas
13lubricationoilforthrust-bearingcooler,1foreachMechanicalflowmeter
guide-bearingcooler,etc.
4.0.2Theconfigurationofflowmonitoringpointsforcommonauxiliarysystemshouldbein
accordancewithTable4.0.2.
5
Table4.0.2Configurationofflowmonitoringpointsforcommonauxiliarysystem
Numberof
No.PositionmonitoringFlowcomponent
points
Outletpipeofcoolingwatersupplypump,
11foreachFlowswitch
firefightingpump,etc.
Lubricatingwatersupplypipeofdeep-well
21foreachFlowswitch
pumpfordewateringsystem
3Outletpipeofdewateringpump1foreachFlowswitch
Lubricatingwatersupplypipeofdeep-well
41foreachFlowswitch
pumpforleakagedrainagesystem
Outletpipeofleakagedrainagepumpin
51foreachFlowmeter
undergroundpowerhouse
Coolingwatermainoutletpipeformain
61Electromagneticflowmeter
transformercoolers
Coolingwaterbranchoutletpipeformain
71foreachFlowswitch
transformercoolers
Lubricationoilmainpipeformain
81Mechanicalflowmeter
transformercoolers
Freezingwateroutletpipeofcold-waterunit
91Flowswitch
forairconditioningsystem
Coolingwateroutletpipeofcold-waterunit
101Flowswitch
forairconditioningsystem
Coolingwateroutletpipeforstatic
111Flowswitch
frequencyconvertercooler
Coolingwateroutletpipeforaircompressor
121foreachFlowswitch
coolers
Coolingwateroutletpipeofoilsumptank
131Flowswitch
coolerforoilpressuresupplysystem
6
5SelectionofFlowComponents
5.0.1Themechanicalflowmetermountedinoilsystempipeshouldbeequippedwithglass.The
flowmetermountedinoilpipeofexternalcirculationsystemformaintransformershallbe
anti-explosiontype.
5.0.2Theflowcomponentsshallmeetthefollowingbasictechnicalrequirements:
1Theflowcomponentsshallworkreliablywithstableperformanceandsimplestructure,
andbeeasyforinstallation,commissioningandmaintenance.
2Alarmsignalshallbesentoutwhentherateofflowenclosedinthepipereachesthe
presetvalue,andthepermissibleerrorbandis±5%.
3Thealarmvalueofflowshouldbeadjustablefrom25%to100%ofthefullscope.
4Theanalogoutputshouldbe4mAto20mA,andthesignalshouldbecurrenttype.
5.0.3Theelectromagneticflowmetershallmeetthefollowingrequirements:
1Theflowmetershallbeequippedwithdevicetodisplayinstantaneousflowrateand
accumulativeflowvolumelocally.
2Theflowmetershouldbeabletooutput4mAto20mAanalogsignalandtwoswitching
signals.
3Themeasurementaccuracyshouldnotbelowerthan2.5%offullscope.
4Themeasurementflowvelocityshallbe0m/sto8m/s.
5TheapplicablepipediametershouldbeDN25toDN1000.
6Thepowersupplyshouldbe24VDCor220VAC.
5.0.4Themechanicalflowmetershallmeetthefollowingrequirements:
1Thepressurelossshallbelessthan0.1m.
2Theflowmetershouldbeflange-connectedandbeeasyfordisassemblyandclean,and
canbeequippedwithaglass.
3Theflowmetershouldbeabletooutput4mAto20mAanalogsignalandtwoswitching
signals.
4Theoutputswitchingsignalshallbezerocorrespondingtomotionlesspressuredfluidin
thepipe,ornofluidinthepipe.
5Themeasurementaccuracyshouldnotbelowerthan2.5%offullscope.
6Themeasurementflowvelocityshallbe0m/sto8m/s.
7Thepowersupplyshouldbe24VDCor220VAC.
5.0.5Thethermalflowswitchshallmeetthefollowingrequirements:
7
1Themeasuringscopeandalarmvalueshouldbeadjustable.
2Theanti-scalingfunctionshallbepossessed.
3Theswitchshallreturntozerowhenthereispressurebutnoflowinthepipeorwhen
thepipeisempty.
4Themeasurementflowvelocityshallbe0m/sto3m/s.
5Theresponsetimeshouldbewithin2sto10s.
6Thepowersupplyshouldbe24VDCor220VAC.
8
6LayoutandInstallationRequirementsofPipes
6.0.1Theflowcomponentsshouldbemountedinthepositionfacilitatingforobservationandoperation.
6.0.2Theinstallationpositionofflowcomponentsshouldavoidhigh-intensitymagneticfieldorstrong
vibration.
6.0.3Forthepipeswithaccurateflowmeasurementrequirements,straightinletandoutletsections
shouldbeplacedinfrontofandbehindflowcomponents.Thelengthofstraightsectionsshouldmeet
followingrequirements:
1Fortheelectromagneticflowmeter,thelengthofinletsectionshouldnotbelessthan5timesthe
pipediameter,andthelengthofoutletsectionnot
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025年-河南建筑安全员B证考试题库附答案
- 2025浙江省安全员A证考试题库附答案
- 江西省赣州市大余县部分学校2024-2025学年高二下学期3月月考语文试卷(含答案)
- 租赁合同纠纷答辩状模板
- 电能计量箱改建项目策划方案
- 电动按摩椅项目实施方案
- 政治社会学 07政治与社会组织学习资料
- 2025年天津建筑安全员《A证》考试题库及答案
- 2025湖南建筑安全员考试题库附答案
- 电力试题题库(1556道)
- 电影《白日梦想家》课件
- 新版中国食物成分表
- 新人教版七年级初一数学下册第一二单元测试卷
- 白内障手术操作规范及质量控制标准(2017版)
- 中国银行履约保函(中英文)
- 不锈钢储罐施工方案(2024043554)
- 自考00911互联网数据库 精华小抄笔记
- 《电子商务法律法规》课程标准
- 中国联通科技创新奖励办法
- 中药饮片储存与养护
- 【《项链》莫泊桑】《项链》课本剧剧本
评论
0/150
提交评论