BJMC

BeijingAustarPharmaPackagingMaterial

DocumentNumberandRevision:

BJMC-02-01-AHU11-FS-1.0

FunctionalDescriptionforAHU11 Page

#

of11

FunctionalSpecificationforAHU11

ProjectName

ExtensionofFilmFacilityHuaiRou

ProjectNo.

BJMCFP201003

Plant/Building

HuaiRou/PCM2

Unit

HVAC

Equipment

AHU11

DocumentCode

BJMC_02_01_AHU11_FS_1.0

Revision

1.0

Name

SignatureReason

Function/Department

Date

Signature

MarkHu

Author

ProjectManager

Tableofcontents

TOC\o"1-5"\h\z

\o"CurrentDocument"

Base 3

\o"CurrentDocument"

Introduction 3

InterfacestootherSystems 3

Timeswitchingfunctions 3

Dependencies 3

Energymanagement 4

Emergencypowerassignments 4

Topologyofautomations, operatingsystem 4

\o"CurrentDocument"

Useraccess 4

Controlfunctions 5

Safetyfunctions 5

\o"CurrentDocument"

Temperature 5

Pressure 5

Humidity 6

\o"CurrentDocument"

Fire 6

Gas 7

\o"CurrentDocument"

Specialfunction 7

Standardfunctions 8

Start-up 8

Shut-down 8

ManualoperationofElectricpanel 9

ThedetailedfunctionspecificationwillbedescribedinFSPLCandelectriccontrolsystem.9

Specialfunctions 9

Regulating 9

Controlloops 9

Temperature 9

\o"CurrentDocument"

Pressure 10

\o"CurrentDocument"

Humidity 10

Specialfunctions 10

RevisionHistory

Reasonsforchangescomparedtopreviousversion

RevisionNo.

Date

Author

DescriptionofChanges

1.0

MarkHu

New

Base

ThisFunctionalDescriptionisbasedupontheUserRequirementSpecification(BJMC_MRS_HVAC_AHU11/12_URS_1.0)forHVACSystemsandP&IDdrawing(BJMC_02_01_AHU11_PID)initcurrentversionanddescribesallautomationfunctionsbelongingtothePLCforthisinstallation.FurthermoretheOQfunctionaltestsoftheinstallationwillbebaseduponthisdocument.

Introduction

Thisdescriptiondefinestherequiredmeasurement,controlandregulatingfunctionsoftheAirHandlingUnit,AHU11.

InterfacestootherSystems

Timeswitchingfunctions

ID

Description

FS3.1-1

TheventilationsystemAHU11istimedforcontinuousoperationandiscontrolledbyPLC.Thesystemcanbedisabledformaintenancepurposesbymeansofhandystoppingoncontrolpanel.

3.2.Dependencies

ID

Description

FS3.2-1

AstheCHWsystemsaretimedforcontinuousoperation,thetemperatureofCHWSis7℃,thetemperatureofCHWRis12°C

FS3.2-2

Freshairissupplieddirectlyfromoutdoor.Andanelectricpower-drivingdamperisinstalledinthefreshairduct;itshouldbeautomaticallyclosedwhentheAHUshutdown.

3.3.Energymanagement

ID

Description

FS3.3-1

Specialenergymanagementsystemisspecifiedduringtheconstructiondrawingbythedesigner.Thereturnairwillberoutedseparatelythroughthefirstreturnairsectionorthesecondreturnairsection.

3.4.Emergencypowerassignments

ID

Description

FS3.4-1

Thereisnospecialemergencypowersystem.

3.5.Topologyofautomations,operatingsystem

Useraccess

Everylogin,logoutandallchangesareloggedinalogfile;alldedicatedpeoplearementionedintheauthorizationlist.Allaccesswillbeautomaticallyreported,exceptthe“everybody”accessforinformationwithoutaction(resetting,parameterandsoftwarechanges).Thefollowinglevelsofuseraccesstothesystemwillbeprovided:

ID

Description

FS3.6-1

Administratorlevel:

FullaccesstotheconfigurationandparametersofthecontrollersbylaptopcomputerorPLCpanel:

OnlythededicatedmaintenancepeopleofAustarorofthemaintenancecontractor.Accessthroughdedicatedpassword.Theseusersareallowedtoaccessandchangeallparameters.

FS3.6-2

Userlevel:

FullaccesstotheconfigurationandparametersfromthelocalPLCpanel:

Accessthroughdedicatedpasswordallowedtoaccessandchangeparameters.

FS3.6-3

Everybodylevel:

AccesstoallofparametersdisplayedonthePLCpanelsforreviewonly.

4.

Controlfunctions

4.1.

Safetyfunctions

4.1.1.

Temperature

ID

Description

FS4.1.1-1

Nosafetytemperaturecontrolisrequiredforthissystem.Buttemperaturealarmfunctionisequipped.Thedetailedfunctiondescriptionseethedocument:BJMC_02_01_AHU11_ALM

Pressure

Supplyductpressure

ID

Description

FS4.1.2.1-1

Asafetypressurevalveswillbeinstalledinthesystem.

4.1.2.2.Differentialpressureofpre-filterG4

ID

Description

FS4.1.2.2

TheFilterDifferentialPressureGaugeofpre-filterG4shallbemonitoredaspartofroutinemaintenance.Ifthedifferentialpressureisabovethemarkedmaximumlimitmaintenanceactionwillbeneeded.Theventilationsystemremainsinoperation.Analarmsignalwillbesenttocontrolpanel,alightandsoundalertwillberaisedbyalamp.

4.1.2.3.Differentialpressureoffine-filterF7

ID

Description

FS4.1.2.3

TheFilterDifferentialPressureGaugeoffine-filterF7shallbemonitoredaspartofroutinemaintenance.Ifthedifferentialpressureisabovethemarkedmaximumlimitmaintenanceactionwillbeneeded.Theventilationsystemremainsinoperation.Analarmsignalwillbesenttocontrolpanel,alightandsoundalertwillberaisedbyalamp.

4.1.2.4.Differentialpressureoffinal-filterH13

ID

Description

FS4.1.2.4

ThereisnoDifferentialPressureGaugeforfinal-filterH13.Specialpressuredifferentialtestdeviceshouldbeequippedinthefilterhouse.Pressuredifferentialtestshallbemonitoredaspartofroutinemaintenance.

4.1.3.Humidity

ID

Description

FS4.1.3-1

Dehumidification

FreshAirisdehumidifiedbycoolerandelectricpowerheaterinsummer.

ID

Description

FS4.1.3-2

humidification

Airishumidifiedbyelectricpowerhumidifierinwinter.

ID

Description

FS4.1.3-3

Humidityalarmfunctionisequipped.Thedetailedfunctiondescriptionseesthedocument:BJMC_02_01_AHU11_ALM.

Fire

ID

Description

FS4.1.4-1

Afiredamperwillbeinstalledinthemainreturnairduct.Thefiredamperswillbeclosedindependentlyiftheanytemperatureisabove70℃.Theclosingtimeofthe“normallyopen”firedampersshouldbe30sec.

Thedamperishardwirelinkedtothecontrolsystem.Ifthefiredamperisclosed,controlsystemwillgiveafiresignaltoPLCsystem,asoftwarealarmmessagewillbesetup.Wholeventilationsystemwillbedisabledasdescribed.

TheventilationsystemwillremaindisableduntilthededicatedfiredamperhasbeenrearmedandtheresetpushbuttononthePLCpanelhasbeenreset.Afterresetting,theinstallationre-startsasdescribedin4.2.1.

FS4.1.4-2

Thefiredamperisallthetimeinopenposition.Otherwisethededicatedinstallationcannotstart(openpositiondetected).

4.1.5.Gas

ID

Description

FS4.1.5-1

Nosafetygascontrolsarerequiredforthissystem.

Specialfunction

Frequencyconverterforsupplyfan(withintegratedoverheatingsensor)

ID

Description

FS4.1.6.1-1

ThefanmotorM101,isprotectedbyfrequencyconvertersVSD101.

Thereisaselectionswitchonthecontrolpanel,thethreefunctionsshouldbeachievedaslistedbelow

TheVSDwillbeautomaticallycontrolledbytheV-sensorinstalledinmainsupplyairduct.

TheVSDcanbecontrolledbyhandyfrequencyadjustment.

ThefanmotorcanbeinoperationbyhandwhentheVSDisdisabled.

4.1.6.2.Frequencyconverterforreturnfan(withintegratedoverheatingsensor)

ID

Description

ID

Description

FS4.1.6.2-1

ThefanmotorM201isprotectedbyfrequencyconvertersVSD201.

Thereisaselectionswitchonthecontrolpanel,thetwofunctionsshouldbeachievedaslistedbelow

TheVSDcanbecontrolledbyhandyfrequencyadjustment.

ThefanmotorcanbeinoperationbyhandwhentheVSDisdisabled.

4.1.6.3.PowerFailure

ID

Description

FS4.1.6.4-1

Anypowerfailurewilldisablethewholeventilationsystem.

4.1.6.4.BuildingShutDown

ID

Description

FS4.1.6.5-1

Nobuildingshutdownisrequiredforthissystem.

4.2.Standardfunctions

Start-up

Supply,returnandexhaustfans

ID

Description

FS4.2.1.1-1

TheAHUstart-upmanually.Andallsystemairdampersarecontrolledbyhand.

FS4.2.1.1-2

Theexhaustfanstart-upmanually.Anditonlycansstart-upatrest.ThesupplyfanshouldbestartedfirstlywhentheAHUsystemstart.

4.2.2.Shut-down

ID

Description

FS4.2.2-1

TheAHUshut-downmanually.

FS4.2.2-2

Theexhaustfanshut-downmanually.Thesupplyfanshouldbeinter-lockedwithexhaustfan,thesupplyfanshouldautomaticallystopwhentheexhaustfanunexpectedstopping,theexhaustfanshouldautomaticallystopwhenthesupplyfanunexpectedstopping

4.2.3.ManualoperationofElectricpanel

Switch

Location

Function

Description

ThedetailedfunctionspecificationwillbedescribedinFSPLCandelectriccontrolsystem.

Specialfunctions

ID

Description

FS4.2.5-1

Nospecialfunctionsrequired.

5. Regulating

Controlloops

Temperature

Roomtemperature

ID

Description

FS5.1.1.1-1

Temperatureandrelativehumidityinroomwillbemonitoringseparatelybylocationgauge.Thedatawillberecordedmanually

5.1.1.2.Returntemperature

ID

Description

FS5.1.1.2-1

ThereturntemperatureTT201ismeasuredinthecommonreturnduct.

Thisreadingaveragesthereturnairtemperaturefromalloftheconnectedrooms.Thissignalcontrolsthesetpointofthesupplytemperatureloop.

5.1.1.3.Supplytemperature

ID

Description

FS5.1.1.3-1

ThesupplytemperatureTT101is

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论