宝洁日化培训课件3-8-015 Valves Do-Don't rv 9-16-2011_第1页
宝洁日化培训课件3-8-015 Valves Do-Don't rv 9-16-2011_第2页
宝洁日化培训课件3-8-015 Valves Do-Don't rv 9-16-2011_第3页
宝洁日化培训课件3-8-015 Valves Do-Don't rv 9-16-2011_第4页
宝洁日化培训课件3-8-015 Valves Do-Don't rv 9-16-2011_第5页
已阅读5页,还剩31页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

Author:DennisMcCulloughCleanDesignPrinciples‘Do/Don’ts’forValveDesignMicro/CleanDesignDo-Don’tsareprimarilyreferencetrainingmaterials;forP&Gprojectexecution,alwaysrefertotheCleanDesignStandards.CleanDesignforValvesValveDesignRequirementsValveTypesBallValvesActuatorButterflyControlDiverterDoubleBlockandBleedFloatDiaphragmGateGlobeManifoldMicro/CleanDesignPrinciplesMicro/CleanDesignPrinciplesCleanDesignforValves(cont.)ValveDesignRequirementsValveTypesNeedlePinchPlugCheckLiftCheckValveMultiportChangeoverMixproofMultiportSampleValvesPipeConnectionsCIP/SIPMINIMALRISK(=standardfornewequipment)MODERATERISKHIGHRISK316LorbetterSS*SS316Not316SSMinimumRa0.8μm(32μinch)Ra0.8-1.0μm(32-42μinch)MuchhigherRaInternalsurfaceshavenopitting,roughness,orcorrosionInternalsurfaceshaveroughnessbutnopittingorcorrosionInternalsurfaceshavepitting,roughness,andcorrosionCheckyourMOCcompatibilitywithyourproduct&sanitizingagentwithCETL!

*Incaseofnewrawmaterialsorcorrosivematerials,refertoCETLMaterialEngineeringexpertMicro/CleanDesignPrinciplesValvesMaterialsofConstructionMoredetails:SeeP&GCleanDesignStandardsoncGMPsiteCleanDesignSpecsforValvesValvesshould:ProvidecompletedrainabilityCIP/SIPcapableAllpartsofthevalvemustcomeintocontactwithCleaningSolutionPolishedsurfacesZerodeadlegsCompatibility–product,ozone,sanitizersMicro/CleanDesignPrinciplesWithregardtoclean/sanitarydesignrequirementsthereisanorderofpreferencewhenselectingvalvesasindicatedabove.Whenselectingvalvesforspecificapplicatione.g.,control;on/off,stop/backflowprevention;refertotheValverisktableforpreferredvalveselection.“Do”“Don’t”ValveDesign*MayrequireadditionalCIP/SIPstepstoachievefullsanitarycomplianceMicro/CleanDesignPrinciplesSanitaryNon-SanitaryButterflyValvesBallValves(otherthanPBM)DiaphragmValvesGate/Plug/Globe/NeedleValvesPiston/Mixproof/RisingStemValvesPBMBallValves(Self-flushingtype)SanitaryCheckValves*SanitaryControlValves*“Do”“Don’t”Micro/CleanDesignPrinciplesValveDesignExample:BallValve:Notrecommendedforuse.Doesnotmeetmicro-cleandesignrequirements.Requiresfulldisassemblyandcleaning.ThePBMself-flushingvalveistheONLYmicroapprovedforsanitarydesign.Example:PBMValve(Left)andBallValve(Right)AccumulationofmaterialsMicro/CleanDesignPrinciplesExampleshownillustratesleftoverproductcanaccumulatewithinvalveinternalsresultinginMICROriskValveDesign“Don’t”Example:BallValvewithinternalthreaddesignMicro/CleanDesignPrinciplesValveDesignAutomatedactuationvalvesareacceptableassumingweareusingacleandesignvalve.ExamplesincludePBMself-flushingballvalves,butterfly,sanitarycontrolvalves,piston/mixproof/risingstemvalves(Mfgs.:AlfaLaval,Definox,orTuchenhagen)areacceptablecleandesignvalvebodieswhichcanacceptanairactuator.“Don’t”Example:AirActuatedBallValve(NotPBMSelf-flushingtype)Micro/CleanDesignPrinciplesValveDesign*SanitarydesignbutterflyvalvesarerecommendedforPurifiedwatersystems.ButterflyValvesareinherentlydrainable,buthaveasmallcreviceatthelocationofthediscandvalveseat,wherethevalvestempassesthroughtothevalvebody.Thiscrevicecreatesariskforpotentialmicrobiologicalgrowth.Thisvalvemayrequireremovaltoinspectand/orcleanthevalveseat/stemarea.ProperdrainagefromButterflyvalvescanbeachievedbyinstallingthevalveataslightanglesuchthatthevalvestemisnotatthebottomofthepipe.Duetotheinherentdesignofthebutterflyvalvethiswouldbeacriticalpointinacleaningandsanitizationvalidation.Example:ButterflyValve“Do”*ThebodyofthecontrolvalveandassociatedpipingarethecriticalcomponentsindeliveringsanitarydesignMicro/CleanDesignPrinciplesValveDesignExample:ControlValve*Generally,thesetypesofcontrolvalvesdonotmeettherequirementsofcleandesignduetotheirlackofdrainabilityanddisassemblyrequirementstodelivercleaningandsanitization;however,properspecificationandselectionofsanitarycontrolvalvemodelsandattentiontoinstallationandpipingdetailscanalleviatetheseissues.TypicalsanitarycontrolvalvesusedinP&GapplicationsareavailablefromFisher-Baumann;Sampson,andSteriflow“Do”*Typicalcontrolvalvebodytypesinclude:-Globeorslidingstem(mostcommon),-Butterfly,-Vee-ball,etc)Micro/CleanDesignPrinciplesValveDesign“Do”*Example:SanitaryControlValve*Generally,thesetypesofcontrolvalvesdonotmeettherequirementsofcleandesignduetotheirlackofdrainabilityanddisassemblyrequirementstodelivercleaningandsanitization;however,properspecificationandselectionofsanitarycontrolvalvemodelsandattentiontoinstallationandpipingdetailscanalleviatetheseissues.SanitaryControlValvesshown.Micro/CleanDesignPrinciplesValveDesignExample:DiverterValveNotrecommended.Doesnotmeetmicro-cleandesignrequirements.Requiresfulldisassemblyandcleaning.“Don’t”Example:DoubleBlockandBleedValveMicro/CleanDesignPrinciplesValveDesignDoesnotmeetmicro-cleandesignrequirements.Requiresfulldisassemblyandcleaning.Doubleblockandbleedusedinasanitarysystemwithnon-sanitaryvalves.Okforuseinnon-susceptiblesystems.UsecleandesignMixproofValveforsanitaryapplications“Don’t”Note:ReferenceSection19.7OfCleanDesignStandardsforproperuseandapplicationOfblockandbleedvalvesinSanitaryapplicationsMicro/CleanDesignPrinciplesValveDesign“Don’t”Doesnotmeetmicro-cleandesignrequirements.Designconcernforopenatmosphericapplicationsmeetingmicrobial/cleandesign.Example:FloatValveMicro/CleanDesignPrinciplesValveDesignExample:DiaphragmValve“Do”DiaphragmValvesaredrainableandareessentiallyfreeofcrevicestocollectwaterorproduct.Thesevalvesareanexcellentchoiceforsanitarydesign.Preferredsanitaryvalveforfluidscontainingasuspendedsolid.Thediaphragminthevalvemustbeinspectedandreplacedonaregularbasistoensurediaphragmintegrity.DiaphragmValvesareavailablewithsanitaryclamporbutt-weldconnectionstomeetsanitarysystemrequirements.Micro/CleanDesignPrinciplesValveDesignExample:GateValve“Don’t”Notrecommendedforuse.Needle,Gate,andPlugValvesareimpossibletosanitizeproperlyandshouldbeavoided.Likeballvalves,thesevalvescanaccumulatewaterindeadareasthatcanleadtomicroorganismproliferation.Micro/CleanDesignPrinciplesValveDesignExample:GlobeValve“Don’t”Notrecommendedforuse.Doesnotmeetmicro-cleandesignrequirements.Requiresfulldisassemblyandcleaning.Shouldonlybeusedinsteamapplications.Micro/CleanDesignPrinciplesValveDesignExample:NeedleValveusedonManifold“Don’t”Notrecommendedforuse.Needle,Gate,andPlugValvesincludingthoseusedonmanifoldsareimpossibletosanitizeproperlyandshouldbeavoided.Likeballvalves,thesevalvescanaccumulatewaterindeadareasthatcanleadtomicroorganismproliferation.A“better”choicewouldbeadiaphragmorself-flushingPBMballvalve.Micro/CleanDesignPrinciplesValveDesignExample:NeedleValve“Don’t”Notrecommendedforuse.Needle,Gate,andPlugValvesareimpossibletosanitizeproperlyandshouldbeavoided.Likeballvalves,thesevalvescanaccumulatewaterindeadareasthatcanleadtomicroorganismproliferation.Micro/CleanDesignPrinciplesValveDesignExample:PinchValveNotrecommendedforuse.Doesnotmeetmicro-cleandesignrequirementsforliquidapplications.Requiresfulldisassemblyandcleaning.“Don’t”Micro/CleanDesignPrinciplesValveDesignExample:PlugValveNotrecommendedforuse.Needle,Gate,andPlugValvesareimpossibletosanitizeproperlyandshouldbeavoided.Likeballvalves,thesevalvescanaccumulatewaterindeadareasthatcanleadtomicroorganismproliferation.“Don’t”Micro/CleanDesignPrinciplesValveDesignExample:LiftType(Flap)CheckValve“Don’t”Lifttypecheckvalvesshouldnotbeusedunlessabsolutenecessary.Theyneedtobespecifiedforsanitarydesign.Thesystemcanbedrainedbyphysicallyremovingthecheckvalveduringsanitizing,orbyinstallingadrainsetupabovethecheckvalveforin-placesanitizing.Ifthisisnotpossible,theymustberemovedandsanitizedonaregularbasis.Note:Onlyusecheckvalveswhereyouhaveto--nevercombinecheckvalvesinlinewithstrainers/filtersthatrequirebackflush.ValveDesignMicro/CleanDesignPrinciples“Do”*Example:CheckValve(Do-All*)Acceptableforuse.Doesmeetmicro-cleandesignrequirements(Moderaterisk)*.CanbedisassembledforcleaningMicro/CleanDesignPrinciplesValveDesignMixproofValve:Recommendforuse.Meetssanitarycleandesignstandards“Do”Example:MixproofValveNote:CanalsobereferredasPiston/Mixproof/RisingStem(Multi-Port)ValvesNote:IfpurchasingtheGEATuchenhagenvalvetheDorBvalveswilldischargeasmallamountoffluideverytimethevalvecyclesandthisdischargeisunavoidable.Ifthisoccurs,theleakagechambermustbepartoftheC&Sprocess.ThereisanothertypeofTuchenhagenMix-proofvalvecalledtheRtype.ThisR-Valveisprovidedspecificallyforthepurposeofpreventingthatdischargeoffluidduringvalvecycling.AlternateselectionistheAlfaLavaldouble-seatdesignMxproofvalve.Micro/CleanDesignPrinciplesChangeoverValve:Recommendforuse.MeetssanitarycleandesignstandardsValveDesignExample:ChangeoverValve“Do”Note:CanalsobereferredasPiston/Mixproof/RisingStem(Multi-Port)ValvesNote:IfpurchasingtheGEATuchenhagenvalvetheDorBvalveswilldischargeasmallamountoffluideverytimethevalvecyclesandthisdischargeisunavoidable.Ifthisoccurs,theleakagechambermustbepartoftheC&Sprocess.ThereisanothertypeofTuchenhagenChangeovervalvecalledtheRtype.ThisR-Valveisprovidedspecificallyforthepurposeofpreventingthatdischargeoffluidduringvalvecycling.AlternateselectionistheAlfaLavaldouble-seatdesignChangeovervalve.Micro/CleanDesignPrinciplesAnyvalvethatrequiresdisassemblyforpropercleaning&sanitizationisnotacceptableandbringsaHIGHMICROrisk.PBMistheonlyvalidated(multi-port)ballvalveallowedperP&Gcleandesignvalvestandards.UseofthePBMballinP&Gsanitaryserviceisrecommendedformicrocleandeignandreliability.Ifautomationrequiredforapplication,reviewuseofcleandesignchangeover/multi-port/piston/risingstemvalve.ValveDesignExample:ManualMulti-PortValve“Don’t”Micro/CleanDesignPrinciplesSampleValve:Example(left)isAlfaLaval.Examplerightisnotsanitarydesign(internalthreads)ValveDesign“Do”“Don’t”Micro/CleanDesignPrinciples“Do”“Don’t”ValveDesignSampleValveApplicationMicro/CleanDesignPrinciples“Do”“Don’t”ValveDesignEnsurevalvematerialselection(316LSS)iscorrecttoavoidproductMicro/QAriskandtomeetcleaningandsanitizingtemperatures(820C(1800F)Micro/CleanDesignPrinciplesValveDesign“Don’t”Avoidboltedflangedand/orinternalthreadedconnectionsMisalignedPipesectionsprovideareasforproductaccumulationProductcanaccumulateinthreadsandatjunctionMicro/CleanDesignPrinciplesValveDesignAvoidboltedflangedand/orinternalthreadedconnections“Do”“Don’t”LowpressuresanitaryclampHighpressuresanitaryclampMicro/CleanDesignPrinciplesValveDesign“Do”“Don’t”SanitaryFlangeconnectiononButterflyValveItisimportanttominimizetheuseofboltedflanges,usedprimarilyatequipmentandinstrumentconnections.Pipemustbeweldedatasmanyjointsaspossible.Byitsverynature,agasketedflangeconnectionisnotasanitarydesign.Theflangesareusuallymachinedorcasttoveryloosetolerances,relativetosanitarydesigntolerances.Thegasketiscutfromalargesheetofmaterial,ofteninthefield.Themate-upofpipesectionsisoftennotstraight,allowingforsmallcrevicesandgasketoverlapthattrapproduct.Goodinteriorcleaning,totheextentrequiredforsanitaryoperation,willusuallyrequiredisassemblyMicro/CleanDesignPrinciplesValveDesignForlargebore

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论