某小区排水管网设计设计_第1页
某小区排水管网设计设计_第2页
某小区排水管网设计设计_第3页
某小区排水管网设计设计_第4页
某小区排水管网设计设计_第5页
已阅读5页,还剩73页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

aa某小区排水管网设计 污水部分设计 1设计概要 1.1设计原始资料·······························································1.2排水系统概论··················································1.2.1排水系统的功能·······················································aa1.2.2排水管道工程····························································1.2.3排水系统规划设计原则···················································1.2.4排水体制及选择···························································1.3排水管网系统规划布置························································1.3.1排水管网布置原则··························································1.3.2排水管网布置形式······················································1.3.3排水管道的衔接方式··················································1.4污水管道定线························································aa2污水设计流量计算·······················································2.1街坊编号并计算其面积及流量计算······································2.2居住区生活污水计算·······················································2.3企业污水流量计算························································2.4污水管道设计参数······················································2.4.1设计充满度······························································aa2.4.2设计流速·······························································2.4.3最小设计坡度···························································2.4.4最小管径······························································2.4.5不计算管段··························································2.4.6最小坡度························································2.4.7污水管道的衔接······················································2.5管段水力计算·····························································2.6污水管道平面图和干管纵剖面图绘制·······································aa3雨水部分设计································································3.1雨水设计原则··························································3.2雨水布管原则····················································3.3设计管段与沿线汇水面积的划分··············································3.3.1设计管段···························································3.3.2沿线汇水面积························································3.4雨水设计流量计算························································3.4.1雨水流量计算及径流系数值····································aa3.4.2暴雨强度公式及各参数的取值·······································3.5雨水管道水力计算····················································3.5.1雨水管道设计参数················································3.5.2雨水管道的衔接···············································3.5.3管道水力计算····················································3.6雨水管道平面图和干管纵剖面·······································aa某城市居住区排水管道设计作者迪丽莎指导教师阿曼达摘要:这次的排水管网的课程设计采用的是分流制的排水体系,是对某城市居住区进行的污水管网与雨水管网的设计,这次设计充分考虑到了地形天气等课程设计任务书上所提供的各种数据及材料,并结合了书本里面所给出的数据与公式进行设计与计算,其中包括污水和雨水干管及主干管的排水管网布置,首先在所提供的城市平面图上进行排水管网的初步设计,通过自己的校核与老师的检查后,选择最长的一条管段进行水力计算,其中包括各设计管段的管长、设计流量、管道数据的选取(流量、流速、管径、充满度)、修改(比如流速不符合的可以增加管径或坡度,对埋深过大的地方采用加泵)。最后绘制污水管网和雨水管网的干管纵剖面图aaCityresidentialareadrainagepipelinedesignAbstractAbstract:thecurriculumdesignofdrainagepipenetworkthisistheseparatedischargesystem,isthedesignofsewagepipenetworkandrainwaterpipenetworkofaresidentialareainourcountry,thedesignfullyintoaccountallkindsofdataandmaterialsprovidedbytheweatherandterraincurriculumdesigntaskbook,andacombinationofdataandthebookisgivenbytheformulafordesignandcalculation,includingthesewageandrainwaterdrainagepipenetworklayoutofpipeandmainpipe,preliminarydesignfirstdrainagepipenetworkincityplanprovidedbytheschool,andtheteacher'sownnucleartests,apipesection,selectthelongestforhydrauliccalculation,includingtheselectionofpipelength,designflow,designofpipelinedataofeachpipesectionofthe(flow,velocity,diameter,fullness),pipelinecapacity,elevation(groundwaterpipe,tube,bottom),andtheburieddepthofpipeline,andthencheckthedataontheunreasonableplacechanges(suchasvelocitydoesnotconformtothecanincreasethediameterortheslope,thedepthofthepumpistoolarge.).Finallydrawthesewageandrainwaterpipenetworkpipeprofile.Keywords:Sewagepipenetwork;rainwaterpipenetwork;hydrauliccalculationaa近年来,随着人们生活质量的不断提高,环保意识的不断加强,对生活用水的水质要求也越统等原因,会给当地的环境造成很大污染,所以排水系统的设计格外重要。课程设计是学习计划的一个重要的实践性学习环节,是对前论、基本技能及专业知识的综合应用。通过课程设计调动了我们学习的积极性和主动性,培养我们分析和解决实际问题的能力,为我们走向实际工作岗位,走向社会打下良好的基础。通过毕业设计使我们具备调查研究、文献检索、综合分析及总体规划设计和细部深入设计的能力,对学科发展新动向有本次课程设计的内容是为某城市居住区设计一套完整的市政排水设施,在国家有关室外排水设计规范的指导下,以及在指导老师的帮助下对该市进行了排水管网系统的设计。设计内容包括排水管网的布设以及各设计管段的水力计算。因此本设计书包括该地区实际情况与要成果包括污水管网平面布置图,设计管段的设计流量计算表,污水主干管的水力计算表,污aa分设计 (2)人口密度及居民生活用水、污水定额表1.1该城区设计参数基本情况人口密度(人/104m2)100350230最高日生活用水定额(L/cap.350230及率及率表1.2居住区日用水量在各时段的变化情况用水量(%)用水量(%)用水量(%)1.706.005.751.675.845.831.635.075.621.635.155.00aa2.563.195.15a4.355.152.695.145.272.585.645.5223~241.87 (3)企业生活、生产的用水、污水情况①企业生活用水情况表1.3企业职工生活及淋浴用水情况使用淋浴职工人企业班每班时数名称数数(h)日(人)最大班最大班日(人) (人)(人)企业一般车间26811414288381高温车间142744629企业一般车间34616819096382高温车间24610810648企业一般车间194849048383高温车间24210213265企业一般车间148699846384高温车间168788640②企业生产用水与废水(生产用水重复利用率为60%)表1.4企业生产废水情况企企业名称平均用水量(L/S)总变化系数aa企业46.4532.159.7539.2532.32.7注:各企业总排水口管底埋深均不小于1.5m. (4)气象、水文、地质资料该地区年平均温度13.6℃,极端最高温度38.6℃,极端最低温度-17℃该地区土壤属黄土类,最大冻土深度68cm.夏季平均气压932毫巴;全年日照60%,冬季63%;夏季室外平均风速2.6m/s,冬季室外平均风速1.7m/s;q=291.2(1+0.75lgP)(L/(s.ha)(t+7)0.65该小区相临河流常年洪水位143.0m,常水位141.0m。1.2排水系统概论1.2.1排水系统的功能1.2.2排水管道工程设计污水、废水的汇集、输送、贮存、调节、提升和排放;要求污水有组织及时的进入1.2.3排水系统规划设计原则 (1)排水系统规划应符合城市和工业企业的总体规划,并应与城市工业企业中期单项工程aaaa(2)排水系统设计要与邻近区域的污水和污泥处理和处置协调; (3)考虑污水的集中处理与分散处理; (4)设计排水区域内需考虑污水排水问题与给水工程的协调,以节省总投资; (5)排水工程的设计应全面规划,按近期设计考虑远期发展; (6)排水工程设计师考虑原有管道系统的使用可能; 须认真观测执行国家和地方有关部门制定的现行有关标准、规1.2.4排水体制及选择排水体制是指排水系统对生活污水、生产废水和降水所采取的不同收集和排除方式,一的合与分而言的。(1)合流制排水系统合流制排水系统是指将生活污水、工业废水和雨水混合在同一套排水管道(渠)内排除直排式合流制排水系统是最早出现的合流制排水系统,是将欲排除的混合污水不经处理侧建造一条沿河岸的截流总干管,所有主干排水管的混合污水都将接入截流总干管中,合流污水由截流总干管输送至下游的排水口集中排出或进入污水处理厂。aaaa为此,在合流干管与截流总干管相交前或相交处需设置溢流井。溢流井的作用是,当进通常是于雨天初降雨的汇集量较小,一般都在截流总干管的设计雨水截流能力范围内,故晴天的城市污水和雨天的初降雨都会排送至污水厂,经处理后排入水体。当降雨过程延续,进入管道的混合污水流量超过截流总干管的设计输水能力后,就有部分混合污水经溢流井溢出直式合流制排水系统是国内外改造旧城区合流制排水系统常用的方式。有部分混合污水未经处理直接排放,(2)分流制排水系统分流制排水系统是指将生活污水、工业废水和雨水分别在两个或两个以上各自独立的管工业废水或城市污水的系统称为污水排水系统,水沿天然地面、街道边沟、水渠等渠道系统排泄,或者为了补充原有渠道系统输水能力的不不完全分流制是指只有污水排水系统,而未建雨水排水系统,雨水沿街道边沟、水渠、天然地面等原有雨水渠道系统排泄,或者在原有渠道系统输水能力不足之处修建部分雨水管aa在工业企业中,一般采用分流制排水系统。由于工业废水的成分和性质很复杂,不但与以及给废水重复利用和回收有用物质造成很大困难。所以,在多数情况下,采用分质分流管道系统分别排除。如果生产废水的成分和性质同生活污水类似时,可将生活污水和生产污水用同一管道系统来排放。水质较清洁的生产废水可直接排入雨水道,或循环重复利用。生活生产污水、雨水分别设置独立的管道系统。初期雨水通过截留管道进入污水处理厂。含有特殊污染物质的有害生产污水,不容许与生活或生产污水直接混合排放,应在车间附近设置局部处理设施。冷却废水经冷却后在生产中循环使用。在条件许可的情况下,工业企业市污水管道。在一座城市中,由于各区域的自然条件存在差异,同时排水系统的建设是逐步进行和完水管道的造价比完全分流制一般要低20%~40%,但是合流制的泵站和污水处理厂却比分流aa在维护管理方面,晴天时污水在合流制管道中只占一小部分过水断面,雨天时才接近满管流,因而晴天时合流制管内流速较低,易于产生沉淀。但据经验,管中的沉淀物易被暴雨水流冲走,这样,合流管道的维护管理费用可以降低。但是,晴天和雨天时流入污水厂的水量变化很大,增加了合流制排水系统中的污水厂运行管理的复杂性。而分流制系统可以保持管内的流速,不致发生沉淀,同时,流入污水厂的水量和水质比合流制稳定很多,污水厂的我国《室外排水设计规范》(GB50014—2006)规定,排水制度(分流制或合流制)的选择,应根据城镇的总体规划,结合当地的地形特点、水文条件、水体状况、气候特征、原有排水设施、污水处理程度和处理后出水利用等综合考虑后确定。同一城镇的不同地区可采。 (1)从环境保护方面来看aa (2)从造价方面来看 (3)从维护管理方面来看晴天和雨天时流入污水厂的水量变化很大,增加了合流制排水系统污水厂运行管理的复杂采用分流制排水系统,即采用两个(雨水、污水)管道系统。1.3排水管网系统规划布置1.3.1排水管网布置原则 (1)按照城市总体规划,结合当地实际情况布置排水管网,要进行多方案的技术经济比较; ; (5)规划时要考虑到使管渠的施工、运行和维护方便; 观测执行国家和地方有关部门制定的现行有关标准、规范和规定。1.3.2排水管网布置形式aa (1)平形式大时,可以减小管道的埋深,避免设置过多的跌水井,改善干管的水力条件; (2)正交式1.3.3排水管道的衔接方式行排水,管道的连接方式是保证管网中的管径变化、方向的改变以及管道高程变化,均需要设置合理的连接方式。排水管道的连接主要采用检查井和跌水井等连接井方式,通常亦统称为窨井。检查井的主要功能是在管道交汇、直线管道中的管径变化、方向的改变处设置,保证衔接通畅,方便清通和维护。跌水井的主要功能是管道表1.5检查井最大间距污水污水管道最大间距200~400aa500~700500~70060aa800~1000800~10008011002000120注:接入检查井的支管(接户管或连接管)管径大于300mm时,支管数不宜超对于跌水井,我国《室外排水设计规范》(GB50014——2006)中规定管道跌水水头为1.0~2.0m时,宜设跌水井;跌水水头大于2.0m时,应设跌水井。管道转弯处不宜设跌水井。跌水井的进水管管径不大于200mm时,一次跌水水头高度不得大于6m;管径为300~600mm时,一次跌水水头高度不宜大于4m。跌水方式可采用竖管或矩形竖槽。管径大于600mm时,其一次跌水水头高度及跌水方式应按水力1.4污水管道定线(1)污水管道定线的基本原则充分利用城市地形、地质、地貌特点,尽可能在管线较短和埋深较小的情况下,让最布置管线是确定污水管道系统总体布置的重要步骤。在定线时应考虑地形等因素的影并考虑设置泵站的合理位置。一般应将主干管和流域干管放在较平坦的集水线上,让污水特殊措施(如跨越河道的倒虹管等),在图上标明。(2)污水管道定线考虑的因素污水管道定线考虑的因素有:地形和用地布局;排水体制和线路数目;污水厂和出水aaaa①在一定条件下,地形一般是影响管道定线的主要因素。定线时应充分利用地形,利用排水系统的布置形式,使管道的走向符合地形趋势,尽量做到顺坡排水,尽可能不设泵站②污水支管的平面布置取决于地形及街区建筑特征,并应便于用户接管排水。③污水主干管的走向取决于污水厂和出水口的位置。④采用的排水体制也影响管道定线。⑤考虑到地质条件,地下构筑物以及其它障碍物对管道定线的影响。尽可能回避不良地质条件的地带和障碍。处理好与现状建筑物,构筑物和规划道路的关系,实在不能避开时⑥管道定线时还需考虑街道宽度及交通情况。⑦管道定线,不论在整个城市或局部地区都可能形成几个不同的布置方案。应进行方案技术经济比较。⑧结合江河走向和规划中道路的实施,合理布置管线,以利于减小施工难度。 (3)污水主干管定线由于排水管道采用分流式的排水体制,污水经收集后由主干管输送到污水处理厂后集中排(4)污水干管定线aa由于北岸具有明显的地势走向,故该区污水干管的布置能够充分利用这种地形顺坡铺面图。2污水设计流量计算2.1街坊编号并计算其面积及流量计算各个街区的面积以及街区的流量见附表一2.2居住区生活污水计算 (1)生活污水比流量计算q=n•p式中n_______居住区生活污水定额(L/(cap﹒d)p_______人口密度(cap﹒ha) (2)各街区生活污水设计流量q=F•q•Kz式中q_______居住区生活污水设计流量(L/s);1q_______比流量(L/(s﹒ha);0F_______设计管段服务的街区面积(ha);K_______生活污水量总变化系数z (3)居民生活污水量变化系数aa根据《室外排水设计规范》(GB50014-2006)相关部分内容,采用的居住区生活污水量变化系数值见表2.1。表2.1生活污水量总变化系数污污水平均日流量(L/s)系数(K)020050052.32.070zzz当5L/s<Q<1000L/s时,K=式中Q――平均日平均时污水量(L/s)。z当Q>1000L/s,K=1.3。z2.3企业污水流量计算 (1)企业生活污水及淋浴污水的设计流量按下式计算:Q+C1D1+C2D2式中Q――工业企业生活污水及淋浴污水设计流量(L/s);A1――一般车间最大班职工人数(cap);A2――热车间最大班职工人数(cap);B1――一般车间职工生活污水定额,以25(L/(cap.班))计;B2――热车间职工生活污水定额,以35(L/(cap.班))计;K1――一般车间生活污水量的时变化系数,以3.0计;aaK2――热车间生活污水量的时变化系数,以2.5计;C1――一般车间最大班使用淋浴的职工人数(cap);C2――热车间最大班使用淋浴的职工人数(cap);D1――一般车间的淋浴污水定额,以40(L/(cap.班))计;D2――热车间的淋浴污水定额,以60(L/(cap.班))计;T――每班工作时数(h)。淋浴时间按60min计。经计算得:企业1Q=1.98L/S2企业2Q=2.63L/S2企业3Q=2.15L/S2企业4Q=1.59L/S2所企业生活污水和淋浴污水设计总流量为Q=8.35L/S2 (2)企业污水设计流量33利率为60%;q――各企业平均用水量(L/S)企业13企业2a企业企业459.7539.252.740.6342.39D或渠道高度H(mm)200-300350-450500-900≧1000最大设计充满度h/D或h/H0.550.650.70.75a所以总污水设计总流量Q=120.29+8.35=128.64(L/S)32.4污水管道设计参数2.4.1设计充满度D图1表2.3最大设计充满度2.4.2设计流速动缓慢,其中的悬浮物容易沉淀淤积;反之,设计流速过高,产生对管壁的冲刷,使得管材aa最小设计流速:污水0.6m/s、明渠0.4m/s。最大设计流速:金属管10m/s、非金属5m/s、明渠查表。压力管流速:建议0.7-1.5m/s。本设计的设计流速全部都控制在0.6m/s左右。2.4.3最小设计坡度在污水管道系统设计时,通常使管道敷设坡度与地面坡度一致,这对降低管道系统的造价非常有利。但相应于管道敷设坡度的污水流速应该等于或大于最小设计流速,这在地势平坦地区或管道逆坡敷设是尤为重要。为了防止其管道的沉淀淤积,所以行业中有规定最小的在设计充满度为0.5时,管径为200mm时,最小设计坡度为0.004;管径为300mm时,最小设计坡度为0.003。街坊厂区内为0.004;街道为0.003。2.4.4最小管径一般在污水管道系统的上游部分,污水设计流量很小,若根据设计流量计算,则设计管污水管道到在街坊和厂区内的最小设计管应为200mm,在街道下的最小设计管径为建议最小设计坡度见表2.4表2.4常用管径的最小设计坡度(钢筋混凝土管非满流)最小设计坡度最小设计坡度0.00150.00120.00100.0008最小设计坡度0.00060.00060.00060.0005管径(mm)000200400500管径(mm)4005006008002.4.5不计算管段最小设计充满度条件下管道通过的流量,则这样的管段称为不计算管段。设计时不再进行水aa2.4.6最小埋设深度衔接—建筑物出户管0.5-0.6m。所以就需要考虑管段控制点(大流量用户和管道的起点)的最小埋深,以确定整个管道的埋深,同时还要考虑地下埋深,考虑地下地质和地下水以及工程造价情况,一般规定,在2.4.7污水管道的衔接方向发生变化及支管接入的地方设置检查井。在检查井中必须考虑上下游管道衔接时的高程关系。管道衔接时应遵循一下两个原则:⑵避免在上游管段中形成回水而造成淤积。常见的衔接方式有:管顶平接、水面平接、设跌水井的方式。2.5管段水力计算⑵将各设计管段的设计流量列入表中。设计管段起讫点检查井处的地面标高列入表中。aa⑶计算每一设计管段的地面坡度,作为确定管道坡度时参考。⑷确定起始管段设计参数确定起始管段的管径以及设计流速v,设计坡度I,设计充满度h/D。首先拟采用最小⑸确定其他管段设计参数确定其它管段的管径D、设计流速v、设计充满度h/D和管道坡度I。通常随着设计流量的增加,下一个管段的管径一般会增大一级或两级(50mm为一级),或者保持不变,这样便可根据流量的变化情况确定管径。然后可根据设计流速随着设计流量的增大而逐段增大合理,将计算结果填入表中相应的项中。在水力计算中,由于Q、v、h/D、I、D各水力因素之间存在相互制约的关系,因此在查水力计算图时实际存在一个试算过程。121v=R3I2n流量公式Q=AV式中Q――流量(m3/s);A――过水断面面积(m2);V――流速(m/s)aa速满足大于或等于aa0.6m/s和充满度满足下表的最大设计充满度,说明坡度I满足情况,然后接着计算下管和主干管的坡度全部确定。表2.5圆形管渠非满流水力计算表AA/A00.0190.0520.0940.1420.1960.252R/R0.1300.2540.3720.4820.5870.684q/q0.0050.0210.0490.0880.1370.196v/v0.2570.4010.5170.6150.7010.776y/D0.050.100.150.200.250.30000aa0.30.350.3120.7740.2630.8430.400.3740.8570.3370.9020.450.4360.9320.4170.6540.500.5001.0000.5001.0000.550.5641.0600.5861.0390.600.6261.1110.6721.0720.650.6881.1530.7561.0990.700.7481.1850.8371.1200.750.8041.2070.9121.1330.800.8581.2170.9771.1400.850.9061.2131.0301.1370.900.9481.1921.0661.1240.950.9811.1461.0751.0951.001.0001.0001.0001.000D——管道直径(m);A——满流过水断面面积(㎡);0R——水力半径(m);R——满流水力半径(m);0q——污水流量(m3/s);q——满流污水流量(m3/s);0v——污水流速(m/s);aav——污水满流流速(m/s)。02.6污水管道平面图和干管纵剖面图绘制风玫瑰或指南针等。已有和设计的污水管道用粗线条表示,在管线上画出设计管段起末点的检查井并边上号码,标出各设计管段的服务面积,可能设置的中途泵站,倒虹管及其他的特殊构筑物,污水厂。初步设计的管道平面图中还应将主干管各设计管段的长度、管径和坡度的主要工程项目表和说明。一般横向1:500~1:2000,纵向1:50~1:200,对工程量较小,地形、地物较简单的污水详aa3.1雨水设计原则城市雨水管渠系统是由雨水口、雨水管渠、检查井、出水口等构筑物组成的整套工程设水管渠系统设计的基本要求是:能通畅、及时地排走城镇或工厂汇水面积内的暴雨径流量;尽量利用池塘、河浜受纳地面径流,最大限度地减少雨水管道的设置;利用地形就近排避免设置雨水泵。充分利用地形,就近排入水体。包括几方面:地形坡度较大时,雨水干管宜布置在地面水体较远,采用集中出水口式的管道布置;地形起伏较大时,雨水干管宜布置在地形低处或水位较远,或雨水排水需泵站提升时,雨水出水口宜相对集中;雨水泵站前的适当位置宜设aa或草地带下,而不宜布置在快车道下。道路宽度大于aa合理设置雨水口,使地面雨水排除通畅。雨水口应根据地形以及汇水面积确定。一般来说,在道路交叉口的汇水点、低洼地段、道路直线段一定距离处(25~50m)均应设置雨水雨水管渠应采用明渠或暗管,应结合具体条件确定。在城市市区或工厂内,雨水管道采用暗管;在城郊,可考虑采用明渠;在每条雨水干管的起端,应尽可能采用道路边沟排除路面雨水;建筑密度较高,交通量较大,雨水管道一般应采用暗管;地形平坦地区,埋设深度或出水口深度受限制地区,可采用盖板渠排除雨水;建筑密度较低,交通量较小的地方,可在每条雨水干管的起端,应尽可能采用道路边沟排除路面雨水;雨水暗管和明渠衔接处需采保证连接触良好的水力条件。3.2雨水布管原则会汇水区域。一般不设泵站。(2)根据街区及道路规划布置雨水管道。通常应根据建筑物的分布、道路的布置以及街坊或小区内部的地形、出水口的位置等布水区域进行划分,使其汇水更加的方便和直接。雨水口的布置应根据地形和汇水面积确定,以使雨水不至漫过路口。一般在道路交叉口(4)采用明渠与暗管相结合的方式。aa卫生情况好,养护方便,不影响交通;在城市郊区或建筑密度低、交通量小的地方可采用明当汇水水体离流域很近,水体的水位变化不大,洪水位低于流域地面标高,出水口的建排放,反之,则应该采用集中出口排放方式,6)调蓄水体的布置。充分利用地形,选择适当的河湖水面作为调蓄池,以调节洪峰流量,减低沟道设计流量7)排洪沟的设置。城市中靠近山麓建设的中心区、居住区、工业区,除了应设雨水管道外,还应考虑在规3.3设计管段与沿线汇水面积的划分3.3.1设计管段雨水管渠的设计管段的划分应使设计管段范围内地形变化不大,管段上下端流量变化查计管段上下游端点的检查井设为节点。3.3.2沿线汇水面积把汇水面积按照周围管渠的布置用等分角线划分;当有适宜的地形坡度时,则按照雨水汇aa图。aa3.4雨水设计流量计算3.4.1雨水流量计算及径流系数的取值式中Q——雨水设计流量(L/s);ψ——径流系数,其值小于1;形地貌、植被分布、建筑密度、在雨水管渠的设计中,通常按地面材料性质确定径流系数的经验数值。我国排水设计规范中的有关径流系数ψ的取值见表3.1。表3.1径流系数ψ值种类各种屋面,混凝土和沥青路面0.85-0.95大块石铺砌路面和沥青表面处理的碎石路面0.55-0.650.40-0.50路面0.35-0.400.25-0.35aa.10-0.20和绿地然而汇水面积是由各种性质的地面覆盖所组成,在整个汇水面积上它们各自占有一定的比例,随它们占有的面积比例的变化,ψ值也不同。所以,如果汇水面积由径流系数不同的地面组合而成。整个汇水面积上的平均径流系数aFa面积用加权平均法计算得出。=iiavFF——汇水面积上各类地面的面积(ha);iiF——全部汇水面积(ha)。实践中,计算平均径流系数时要分别确定总汇水面积上的地面种类及其相应面积,计算表3.20.4-0.60.5-0.8本设计取综合径流系数值为0.63.4.2暴雨强度公式及各参数的取值式中q

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论