版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
摘要本建筑为拟建于大庆市开发区的夏宫休闲娱乐休闲中心,总建筑面积为5184m2。主体高度12.6m,由游泳池及洗浴办公区构成。场地类型为Ⅱ类场地,地震分组为第二组,抗震烈度为7度。设计内容主要包括:建筑设计和结构设计。建筑设计部分包括总体布局、平面与竖向交通、建筑朝向与选型以及防火和疏散要求。主要进行了建筑设计构思,平面布局、立面设计、剖面设计以及防火和疏散设计。平面布局合理、立面简洁大方,满足功能要求。结构设计部分包括:结构布置、荷载计算、内力组合、钢框架设计、网架设计以及基础设计。完成了该建筑的结构设计说明书及部分施工图。本建筑上部结构采用钢结构体系,下部采用独立基础。关键词:钢结构;建筑设计;内力组合;钢框架;独立基础AbstractThisbuildingisatiersteelframestructuralrecreationground,whichistobebuiltintheSummerpalaceofDaqingCity.Itstotalareais5184squaremeters.Itsoverallheightis12.4metersandconstructedwiththeswimmingpoolandofficearea.Theareaisthesecondtypearea,andthesecondgroupinearthquakeresistanceintensity.Thisarticleincludestwopartsthatarearchitecturedesignandstructuraldesign.Architecturedesignincludesthetotallayout,planeandtheperpendiculartransportation,theorientationofthebuildingandchoosesthesize,andthedesignoffireproofanddispersion.theplane’sarrangementisreasonable,anditssemblanceissuccinctandgenerous,whichsatisfiesthefunction’srequirement.Thestructuredesignincludeswhatisfollowingasthestructurearrangement,thecalculationofloads,thecombinationoftheinternalforces,thecalculationoftheframe;thecalculationofthecrane’sbeamandthecalculationofcolumnandfoundation.Themethodofbottomshearingforceisusedtocalculatethelateralseismicaction.Inaccordingtothegeologiccondition,spreadfoundationisadopted.Throughthecalculatinganddesigning,theinstructionofstructuredesignofthebuildingandsomeconstructionplansarefinished.Thestructuresystemofallsteelframesisadoptedinthebuilding’stopstructureandthespreadfoundationisadoptsinitsfoundationstructure.Keywords:Steelstructures;architecturedesign;thecombinationoftheinternalforces;structuresteelframe;spreadfoundation目录TOC\o"1-2"\h\z\uHYPERLINK\l"_Toc108247065"第1章建筑设计1HYPERLINK\l"_Toc108247066"1.1夏宫休闲娱乐中心组成1HYPERLINK\l"_Toc108247067"1.2平面设计1HYPERLINK\l"_Toc108247068"1.3剖面设计2HYPERLINK\l"_Toc108247069"1.4立面设计及内部空间处理3HYPERLINK\l"_Toc108247070"第2章结构设计4HYPERLINK\l"_Toc108247071"2.1荷载计算4HYPERLINK\l"_Toc108247072"2.2钢框架设计7HYPERLINK\l"_Toc108247073"2.3组合楼板设计51HYPERLINK\l"_Toc108247074"2.4网架设计55HYPERLINK\l"_Toc108247075"2.5檩条设计63HYPERLINK\l"_Toc108247076"2.6基础设计65HYPERLINK\l"_Toc108247080"结论69HYPERLINK\l"_Toc108247081"参考文献70HYPERLINK\l"_Toc108247082"致谢71第1章建筑设计1.1夏宫休闲娱乐中心的组成1.1.1夏宫休闲娱乐中心简介夏宫休闲娱乐中心的组成体系由游泳区及洗浴办公区组成。游泳区是休闲娱乐中心的基本休闲单位,洗浴办公区是其附属单位,洗浴办公区组成部分包括浴池,休息区(包括休息大厅,游艺室,健身区等内容),休闲中心职工办公区,职工休息区。1.1.2构件的组成1.1.2.1承重结构本承重结构主要采用局部钢框架结构,这主要是因为泳池及办公区使用空间不同、高度较低,这种结构受力合理,建筑设计灵活,施工方便,工业化程度较高。它包括下列几部分承重构件:(1)横向框架:由基础、框架梁、柱组成。(2)纵向框架:由基础、框架梁、柱组成。(3)游泳池区:有柱,网架组成。1.1.2.2围护结构本建筑物的外围护结构包括外墙、屋顶、地面、门窗等。1.2平面设计本建筑物的平面设计主要研究以下几方面的问题:(1)总平面对平面设计的影响;(2)平面设计与不同功能分区的关系;(3)平面设计与人流的关系;(4)柱网选择;(5)生活间设计;1.2.1总平面对平面设计的影响平面设计根据全建筑物的人流流程、交通运输、卫生、防火、气象、地形、地质以及建筑群体艺术等条件,确定这些建筑物与构筑物之间的位置关系;合理的组织人流、货流,避免交叉和迂回;布置各种工程管线;进行竖向设计及绿化、美化布置等。1.2.2平面设计与不同功能分区的关系民用建筑的平面及空间组合设计,主要是根据建筑物使用功能的要求进行的;而休闲娱乐中心平面及空间组合设计,则是在泳池及其附属结构布置的基础上进行的。本设计,主要包括下面五个内容:(1)根据任务书要求的规模、性质等确定的总建筑面积;(2)选择和布置泳池及其附属结构;(3)划分泳池及其附属结构面积;(4)初步拟定柱网跨度和长度;(5)使用功能对建筑设计的要求,如采光、通风、保温、防潮等。1.2.3平面设计与人流的关系为了方便娱乐人员,客户,职工出入,并且不出现人流交叉而布置。总之,平面设计时,必须考虑周围建筑物的影响及要求。1.2.4柱网布置本设计柱距采用6m×6m。1.2.5休息空间布置为保证游泳及洗浴人员休息而设置休息大厅、餐厅、健身区等。1.3剖面设计剖面设计的具体任务是:确定建筑高度;选择承重结构及围护结构方案;游泳池上空的采光、通风及屋面排水等问题。在本设计中,建筑高度为12.6m,承重结构为钢框架,维护结构为砌体结构,游泳池上空为大空间网架。1.3.1高度的确定确定建筑的高度必须根据使用要求以及建筑统一化的要求,同时,还应考虑到空间的合理利用及功能的需求。建筑高度直接影响建筑的造价,在确定建筑高度时,应不影响生产使用的前提下,充分发掘空间的潜力,节约建筑空间,降低造价。在本设计中,层高为4.2m,游泳池层高为12.8m,1.3.2天然采光白天,室内利用天然光线进行照明的叫做天然采光。由于天然光线质量好,又能节约能源,只有天然采光不能满足要求时才辅以人工照明。在本设计中,办公区采用人工采光,游泳馆上空采用天然采光。1.4立面设计及内部空间处理建筑物的体型与使用功能、平面形状、剖面形式和结构类型都有着密切的关系,而立面处理又是在建筑体型的基础上进行的。建筑平面、立面、剖面三者是一个有机体,设计虽然是首先从平面着手,但自始至终应将三者结合考虑和处理。立面应根据使用功能要求、技术条件、经济等因素,运用建筑构图原理进行设计,使建筑物具有更加简洁、大方、新颖的外观形象。1.4.1立面设计由于泳池的大空间及洗浴办公区的小空间,因此在立面设计中墙面划分很关键,墙面的大小、色彩与门窗的大小、位置、比例、组合形式等,直接关系到立面效果。在工程实践中,墙面划分常采用三种方法:(1)垂直划分;(2)水平划分;(3)混合划分。本设计中,正立面采用玻璃幕墙,上空采用大空间网架造型优美,活泼。1.4.2内部空间处理影响内部空间处理的因素有以下几个方面:(1)使用功能内部空间应满足功能要求,同时也应考虑空间的艺术处理。(2)空间利用设置在内部的职工生活空间使用方便,可用死角作为仓库,同时利用的空间来布置生活设施,这样可充分利用空间,降低造价。利用距离泳池最近房间作为急救室,方便区域作为广播室,大厅入口处设置前台,侧面设置存鞋处等。(3)设备管道有条不絮地组织排列设备管道,不但方便使用,而且便于管理和维修,其布置和色彩处理得当,会增加室内艺术效果尤其是泳池处玻璃幕墙后面的柱及柱间支撑。(4)建筑色彩在内部的应用建筑色彩受世界流行色的影响,虽然目前世界上趋向清淡或中和色,但鲜艳夺目的色彩仍广泛使用。建筑中墙面、地面、天棚的色彩应根据性质、用途、气候条件等因素确定。第2章结构设计2.1荷载计算2.1.1设计资料大庆市开发区夏宫休闲娱乐中心,该厂房建筑物为局部三层,三层部分采用钢框架结构,单层部分采用大空间网架结构;长60m,宽度48m;共有4榀钢框架,柱距6.0m,屋面彩板坡度2%,网架部分屋面坡度为2%;地震设防烈度为7级,设计地震分组为第二组,设计地震基本加速度值0.05g。另附平面布置图,见图2-1;框架形式及框架尺寸见图2-2。钢框架屋顶为彩色钢板夹聚苯乙烯保温板,空间网架上空为有机玻璃。图2-1刚架平面布置图2.1.2荷载计算2.1.2.1荷载取值计算1、楼面、屋面永久荷载标准值(对水平投影面)压型钢板及保温层:0.12kN/m2檩条:0.10kN/m2屋架及支撑自重:0.384kN/m2水磨石地面:0.65kN/m274+46厚现浇混凝土板:2.5kN/m220厚板底抹灰:0.02×17=0.34kN/m2YX-70-200-600压型钢板:0.221kN/m2外墙空心小砌块:11.8kN/m3内墙陶粒空心砌块:5kN/m3塑钢门:0.4kN/m2塑钢窗:0.4kN/m2外墙面荷载:11.8×0.4+17×0.02+0.5=5.56kN/M2内墙面荷载:5×0.4+17×0.02+0.5=2.84kN/M2轻质墙面及柱自重标准值(包括柱、墙骨架等)0.50kN/m2。图2-2钢框架形式及尺寸2、初选截面选定梁柱截面尺寸及截面几何特性钢材均为Q235柱:H300X305X15X15:A=135.4cm2;Ix=21600cm4;W1x=1440cm3;ix=12.6cm;Iy=7100cm4;iy=7.24cm;q=106kg/m。一二层梁:H300X300X10X15:A=120.4cm2;Ix=20500cm4;W1x=1370cm3;ix=13.1cm;Iy=6760cm4;Wy=450cm3;iy=7.49cm;q=94.5kg/m。顶层梁:H125X125X6.5X9:A=30.31cm2;Ix=837cm4;W1x=44.01cm3;ix=5.29cm;iy=3.11cm;q=23.8kg/m。3、地震作用具体计算见横向地震荷载计算。图2-3梁柱截面尺寸示意图2.1.2.2作用在屋面及楼面的荷载标准值屋面可变荷载标准值屋面活荷载:按不上人屋面考虑,取为0.50kN/m2雪荷载:基本雪压S0=0.35kN/m2。按雪荷载均匀分布,ur=1.0,雪荷=1.0×0.35=0.35kN/m2。风荷载标准值基本风压w0=0.55kN/m2,地面粗糙度类别为B类,风荷载高度变化系数按《建筑结构荷载规范》(GB50009——2001)的规定采用,柱顶:H=12.6m,uz=1.07楼面:办公区活荷载取值2.0kN/M2宿舍区活荷载取值2.0kN/M2餐厅区活荷载取值2.5kN/M2休息大厅活荷载取值3.0kN/M2健身区活荷载取值3.5kN/M2走廊、楼梯活荷载取值3.5kN/M22.2钢框架设计设计资料钢框架柱距为6.0mX6.0m,层高为H=4.2m,,无挡风板,间距6.0m,屋面材料为压型钢板,屋面坡度为2%,钢材选用为Q235型,焊条采用E43型,天窗架几何尺寸、结构形式及杆件编号如图2-6所示。图2-4钢框架左一半荷载标准值汇集2.2.2.1永久荷载2.2.2.1.1屋面恒载屋面板(压型钢板)0.12kN/m2檩条0.10kN/m2屋架及支撑自重0.384kN/m2小计0.604kN/m2边跨框架梁自重0.945kN/m小计0.945kN/m中跨(BC跨)框架梁自重:0.945kN/m小计:0.9455kN/mm边柱连系梁自重::0.5×00.945××6=5.67kNN连系梁传来屋架自自重:0.5×00.604××6=3.6244kN顶层边节点集中荷荷载标准值::9.29kNN顶层中节点集中荷荷载标准值::18.588kN2.2.2.1..1标准层框架架恒荷载水磨石面层:0.65kN//m274+46mm厚厚现浇钢筋混混凝土楼板::==2.5kNN/m220厚板底抹灰::0.022×17=0..34kNN/m2YX-70-2000-6000压型钢板:0..221kkN/m2屋面吊顶0.2kN/m22楼面恒荷载:3.888kN//m2边跨框架梁:0..945kNN/m中跨框架梁:0..945kNN/m楼面板传给中跨(35)框架梁荷荷载:3.88××2=6.98kkN/m中跨(35)框架架梁线荷载标标准值:6.98++0.9455=7.9225kN//m楼面板传给边跨(13)框架梁荷荷载:3×0.111×25==8.3899kN/m中跨(35)框架架梁线荷载标标准值:111.25++2.5+00.945==14.6995kN/mm边跨框架联系梁::0.9455kN/m钢窗自重:1.88×2.1××0.4=1.51kNN窗下墙体自重:55.56×00.9×1..8=9.01kNN窗边墙体自重:55.560..64.2=14kN框架柱自自重:1.06××4.2=4.45kNN连系梁传来楼面自自重:11.255×3+3..49×3××1=44.222kN标准层边柱中荷载载标准值:78.86kNN中柱连系梁自重::0.9455kN联系梁传来的集中中荷载:3.49××3×2=220.94kkN小计26..61kN扣除门窗洞加上门门窗重:5××4.2×66-5×2..4×2.44+0.4××2.4×22.4=999.5kN标准层中结点集中中荷载标准值值:99.5++26.611=126..11kN2.2.2.1..1底层框架相相关荷载计算算水磨石面层:0.65kN//m274+46mm厚厚现浇钢筋混混凝土楼板::==2.5kNN/m220厚板底抹灰::0.022×17=0..34kNN/m2YX-70-2000-6000压型钢板:0..221kkN/m2屋面吊顶0.2kN/m22楼面恒荷载:3.888kN//m2边跨框架梁:0..945kNN/m中跨框架梁:0..945kNN/m楼面板传给中跨(35)框架梁荷荷载:3.88××2=6.98kkN/m中跨(35)框架架梁线荷载标标准值:6.98++0.9455=7.9225kN//m楼面板传给边跨(13)框架梁荷荷载:3×0.111×25==8.3899kN/m中跨(35)框架架梁线荷载标标准值:111.25++2.5+00.945==14.6995kN/mm边跨框架联系梁::0.9455kN/m钢窗自重:1.88×2.1××0.4=1.51kNN窗下墙体自重:55.56×00.9×1..8=9.01kNN窗边墙体自重:5..560.664.2=14kN框架柱自自重:1.064..2=4.45kNN连系梁传来楼面自自重:11.2553+3.44931=44.222kN底层边柱中荷载标标准值:778.86kNN中柱连系梁自重::0.9455kN联系梁传来的集中中荷载:3.49332=20..94kN小计26..61kN扣除门窗洞加上门门窗重:54..26-52.442.4+00.42.442.4=999.5kNN底层中结点集中荷荷载标准值::99.5++26.611=126..11kN2.2.2.2活荷载计算算2.2.2.2..1屋面框架活活荷载计算中跨主梁由屋面传传递的均布活活荷载:60..5=3kNN/m屋面传递给边跨连连系梁活荷载载:6330.5=99kN屋面传递给中跨连连系梁活荷载载:6660.5=118kN2.2.2.2..2标准层活荷荷载计算中跨主梁均布活载载:33+3.552.4+00.62=118.6kNN/m楼面传递给次梁的的活荷载:2.523+223=27kkN楼面传递给给边跨系梁活活荷载:2.532=15kkN屋面传递给中跨连连系梁活荷载载:2.5516+216=27kkN2.2.2.2..3底层活荷载载计算中跨主梁均布活载载:33+3.552.4+00.62=118.6kNN/m楼面传递给次梁的的活荷载:2.523+223=27kkN楼面传递给给边跨系梁活活荷载:2.532=15kkN屋面传递给中跨连连系梁活荷载载:2.5516+216=27kkN2.2.3屋盖盖、楼盖重力力荷载代表值值Gi的计算2.2.3.1屋盖重力荷荷载代表值Gn的计算。1)屋架架自重:g1=0.60042448+00.30.5548=11156.6kkN2)横纵梁恒载:g2=0.2338637+0..23898=69..97kN3)半层高外墙恒载::g33=5.5662.1(448+48))=11200.89kNN4)半层高内墙荷载::g4=[(3..6+9)44+3.622+612]]2.82.11=772..93kN5)半层柱高荷载:g5=1.0662.153==117.996kN=11120.889kNG3=∑g=3623.661kN2.2.3.2二层楼盖重重力荷载代表表值Gi的计算1)楼面荷载:g11=(3.49++2.50..5)4824=55460.448kN2)横纵梁荷载:g2=0.9445637+0..94598=2777.83kNN3)上下层半高外墙荷荷载:g33=11200.892==2241..78kN4)上下层半高内墙荷荷载:g44=772..932=11545.886kN5)上下层半高柱自重重荷载:g55=117..982=2235.966kNG2=∑g=9761.991kN2.2.3.3底层楼盖重重力荷载代表表值Gi的计算1)楼面荷载:gg1=(3.49++2.50..5)X48X224=54660.48kkN2)横纵梁荷载:g2=0.9445637+0..94598=2777.83kNN3)上下层半高外墙荷荷载:g33=11200.892==2241..78kN4)上下层半高内墙荷荷载:gg4=772..932=11545.886kN5)上下层半高柱自重重荷载:g55=117..982=2235.966kNG1=∑g=9761.991kN合计Gi=∑G=2347..43kN表2-1重力荷载载代表值计算算表层数321Gn、kN3924.619761.919761.912.2.4水平平地震作用下下框架的侧移移计算2.2.4.1梁线刚度钢框架结构中,考考虑现浇钢筋筋混凝土楼板板与钢梁的共共同作用,在在计算梁线刚刚度时,对中中框架梁取Kb=2.0EEIb/l;对边框架取Kb=1.5EIb/l。底层框架为例:EXIb/l=22.061005205000/60000=1.377109(kN·m))表2-2梁线刚度度表梁号惯性矩I0X1004/cm4EXIb/lkN·mKbX104/(kkN·m)中框架梁2.0KKb边框架梁1.5KKb顶层框架梁8372.75X10775.5X1074.2X107一、二层框架梁205000.865X10091.37X10991.03X10992.2.4.2柱线刚度一、二、三三层柱线刚度度Kc=EXIc/h==2.061105216000/42000=1.0333109(kN·m))2.2.4.3横向框架柱柱侧翼刚度D值D即是使两端固定的的柱上、下端端产生相对水水平位移时需需要在柱顶施施加的水平力力。以底层框架3柱为为例==(1.37+1.003)/1.0333=2.332(kN··m)αc=(0.5+)/(++2)=(0.5+22.32)/(2.332+2)==0.6512/h2=0..68D=12α/hh2=1.02254kN//mΣD=0.3383342+1..025488+1.18812=366.57kkN/m2.2.4.4横向框架自自振周期按顶点位移法计算算框架基本自自振周期T1=1.7ξT以顶层为例:层间相对位移δ33==7.144/39233.61=00.05499(m)μn=Σδi=0.16676(m))T1=1.7ξT=11.70.99=0.6226(S)表2-3横向框架架1柱抗侧移刚刚度D值计算楼层层高m线刚度Kc=EIIc/h(kN·m)=(底层)=(一般层)αc=(0.5+)/(++2)(底层)αc=/(+2)(一般层)D=12αc/h234.21.033X10090.5180.2060.072624.21.033X10090.9970.3330.225814.21.033X10090.9970.4990.3383表2-4横向框架架3柱抗侧移刚刚度D值计算楼层层高m线刚度Kc=EIIc/h(kN·m)=(底层)=(一般层)αc=(0.5+)/(++2)(底层)αc=/(+2)(一般层)D=12αc/h234.21.033X10091.210.380.312724.21.033X10092.320.540.851914.21.033X10092.320.651.0254表2-5横向框架架5柱抗侧移刚刚度D值计算楼层层高m线刚度Kc=EIIc/h(kN·m)=(底层)=(一般层)αc=(0.5+)/(++2)(底层)αc=/(+2)(一般层)D=12αc/h234.21.033X10091.380.410.384724.21.033X10092.590.560.986214.21.033X10092.590.671.1800表2-6横向框架架6柱抗侧移刚刚度D值计算楼层层高m线刚度Kc=EIIc/h(kN·m)=(底层)=(一般层)αc=(0.5+)/(++2)(底层)αc=/(+2)(一般层)D=12αc/h234.21.033X10091.380.410.384724.21.033X10092.590.560.986214.21.033X10092.590.671.1800表2-7横向框架架8柱抗侧移刚刚度D值计算楼层层高m线刚度Kc=EIIc/h(kN·m)=(底层)=(一般层)αc=(0.5+)/(++2)(底层)αc=/(+2)(一般层)D=12αc/h234.21.033X10091.380.410.384724.21.033X10092.590.560.986214.21.033X10092.590.671.1800表2-8横向框架架定点位移计计算楼层Gi/kN∑Gi/kNDi/(X104kNN)层间相对位移δi=Δi/m33623.613623.617.410.05490.167629761.9113685.52228.130.04860.112719761.9123447.43336.570.06410.06412.2.4.5横向框架水水平地震作用用计算此建筑物高度不超超过40m,且平面和和竖向较规则则和以剪切变变形为主的建建筑,故地震震作用计算采采用底部剪力力法。阻尼比比为GEq=0.85GGE=0.855234477.43=119930..32kN=(0.35/00.626))0.91.00X0.088=0.0447结构总水平地震作作用等效的底底部剪力标准准值FEK=GEq==0.0477199300.32=9936.722kN定点附加水平地震震作用系数Tg=0.35s,TT1=0.6226s>1.40.335=0.449s查表得δn=0.08T11+0.077=0.0880.6266+0.077=0.122顶点附加水水平地震作用用ΔFn=δnXFEK=00.129336.72==112.44kN各层水平地地震作用标准准值计算:以顶层为例例=494379336.72(1-0..12)/223447..43=2336.58kkN加入ΔFnn后F3=112..4+2366.58=3348.988kN2.2.44.5.1各层地震作作用及楼层剪剪力表2-9横向框架架各层地震作作用及楼层地地震剪力层数hi/mHi/mGi/kNGiHi/kNN·mFi/kNVi/kN34.212.63923.61494370.287348.98348.9824.28.49761.91820000.476445.88794.8614.24.29761.91410000.238222.941017.8F3加入ΔFn图2-5地震作用用示意图2.2.4.5..2各楼层地震震剪力最小取取值验算各楼层地震剪力最最小取值验算算,满足Vi<。表2-10楼层地地震剪力最小小取值验算层数Vi/kNGi/kN3348.983923.6162.782794.869761.96218.9711017.89761.96375.16*表中λ=0.0162.2.4.6横向框架侧侧移计算框架水平位移可分分为两部分::由框架梁弯弯曲变形产生生的位移uM和由柱子轴轴向变形产生生的位移uN,框架顶端端位移为:u=uM+uN。表2-11层间位位移验算层数层间剪力层间刚度层间位移Vi/DDi/m层高hi/mum3348.98714000.004894.20.010492794.862812000.002824.20.0056011017.83657000.002784.20.00278以三层为例:层间位移:Ui=348.98//714000=0.000489(mm)高层钢框架中柱轴轴力较大,由由柱子的轴向向变形产生的的框架顶点水水平位移也比比较大,不能能忽略。框架受到倒三角形形水平分布荷荷载(将集中中水平地震作作用折算成倒倒三角形分布布的水平荷载载),顶端荷荷载强度为q时n=A1/Am==1(柱截面沿高高度不变)所以Fn=1/3q==3(3448.98112.6+4445.8888.4+2222.9444.2)//12.622=171..56kN//MuN==171.56112.841/3/222.0610080.01335448==0.004479u=um+uN==0.010049+0..004799=0.011969m图2-6层间位移移示意图2.2.5框架架在水平地震震作用下的内内力计算2.2.5.1反弯点高度度比根据该框架总层数数及该层所在在层数梁柱线线刚度比k值,且荷载载近似倒三角角形,差的反反弯点高度比比yn。表2-12水平地地震作用下每每柱剪力计算算层数层剪力/kN1柱D值3柱D值5柱D值6柱D值8柱D值ΣD3388.980.07260.31270.38470.38470.38479.732794.860.22580.85190.98620.98620.986228.1311017.80.33831.02541.181.181.1836.57层数1柱剪力3柱剪力5柱剪力6柱剪力8柱剪力39.7311.2213.7913.7913.7926.3824.0727.8727.8727.8719.4128.5432.8432.8432.842.2.5.2框架柱剪力力及弯矩计算算在水平荷载作用下下,框架内力力及位移可采采用D值法进行简简化计算。以顶层边柱为例每柱剪力Vi=VVDi/ΣD=3488.980..0726//9.73==2.6kNN反弯点y=0.551m柱顶截面处弯矩为为M上=2.64..2)=1..274kkN·m柱顶截面处弯矩为为M下=2.60..514.22=1.3226kN··m表2-13水平地地震作用下内内力计算N=348.988KnN=3,j=3ΣP=348.988kNΣD=9.73α=0.206yy0=0.311K=0.518α1=0.388D=0.07266y1=0.2V=2.6kNy=0.551M上=1.2774kN··mM下=1.3226kN··mα=0.38y00=0.411K=1.21αα1=0.388D=0.31277y1=0.2V=11.22kkNyy=0.611MM上=4.3776kN··mM下=6.8444kN··mα=0.41y0=0.422K=1.38α1=0.388D=0.38477y1=0.2V=13.79kkNy=00.62M上=5.077kN·mmM下=8.5449kN··mα=0.41y0=0.422K=1.38α1=0.388D=0.38477y1=0.2V=13.79kkNy=00.62M上=5.077kN·mmM下=8.5449kN··mN=445.888KnN=3,j=2ΣP=794.866kNΣD=28.13α=0.333yy0=0.455K=0.997α3=1D=0.22588y3=0V=6.38kNNy=0..45M上=3.5009kN··mM下=2.8771kN··mα=0.54y00=0.5K=2.32αα3=1D=0.85199y3=0V=24.07kkNy=0.55MM上=12.0035kNN·mM下=12.0035kNN·mα=0.56y00=0.5K=2.59αα3=1D=0.98622y3=0V=27.87kkNy=0.55M上=13.9935kNN·mMM下=13.9935kNN·mα=0.56y00=0.5K=2.59αα3=1D=0.98622y3=0V=27.87kkNy=0.55M上=13.9935kNN·mMM下=13.9935kNN·mN=222.944KnN=3,j=1ΣP=1017.88kNΣD=36.57α=0.499yy0=0.655K=0.997α2=1D=0338y2=0V=9.41kNNy=0..65M上=3.2993kN··mM下=6.1117kN··mα=0.65y00=0.5885K=2.32αα2=1D=1.02544y2=0V=28.54kkNyy=0.5885M上=11.884kN··mM下=16.6696kNN·mα=0.67y0=0.577K=2.59α2=1D=1.18y2=0V=32.84kkNy=00.57M上=14.1121kN··mMM下=18.7719kNN·mα=0.67y0=0.577K=2.59α2=1D=1.18y2=0V=32.84kkNy=00.57M上=14.1121kN··mM下=18.7719kNN·m2.2.5.3框架梁端弯弯矩、剪力及及柱轴力计算算以顶层1-3跨梁梁为例M左=1.274kkN·mM右=4.3776/2=22.188kN·mVb=(M左+M右)/L=(1.2744+2.1888)/6=0..577kNN顶层边柱轴力V11=-Vb=-0.5577kN表2-14横向框框架梁端弯矩矩、剪力、及及柱轴力位置l/m1-3跨3-5跨5-6跨6-8跨柱轴力M左M右VbM左M右VbM左M右VbM左M右VbN1N3N5N6N83层61.2742.1880.5772.1882.5350.7872.5352.5350.8452.5352.5350.845-0.577-0.21-0.08502层64.7839.4392.379.43911.2423.44711.24211.2423.74711.24211.2423.747-2.947-1.287-0.38501层66.16411.9383.01711.93814.0284.32814.02814.0284.67614.02814.0284.676-5.964-2.598-0.7330图2-7水平地地震作用下框框架弯矩图图2-8水平地地震作用下框框架剪力及轴轴力图2.2.6竖向向荷载作用下下横向框架的的内力计算2.2.6.1荷载计算框架梁在三分点处处受到的恒荷荷载标准值、活活荷载标准值值图2-9竖向荷荷载分布图2.2.6.2用弯矩分配配法计算框架架弯矩2.2.6.2..1固端弯矩计计算以一层1-3跨恒恒载为例计算算框架梁固端端弯矩为:MA=MB=2PPl/9=22126.11086/99=168..14kNN·m表2-14梁固端端弯矩计算位置恒载集中值/kNN活载集中值/kNN恒载MA=MB(kN·mm)活载MA=MB(kN·mm)边跨中跨边跨中跨3层0.6040.51.671.671.623.242层126.10827168.14168.1436361层126.10827168.14168.1436362.2.6.2..2分配系数计计算考虑对称框架在对对称荷载作用用下,取半框框架进行计算算。图2-10梁柱线刚刚度分配系数数以1柱底层框架为例μ下柱=1.0333/(1.0333+1.033+1.0333)=0.3445μ右梁=1.03//(1.0333+1.033+1.0333)=0.34442.2.6.2..3传递系数远端固定,传递系系数为0.5,远端滑动动铰支,传递递系数为-12.2.6.2..4弯矩分配表2-15恒载作作用下弯矩分分配三层上柱下柱右梁左梁上柱下柱右梁左梁上柱下柱右梁左梁上柱下柱右梁左梁上柱下柱00.9570.0430.04100.9060.0540.05300.8940.0530.05300.8940.0530.05300.944-1.671.67-1.671.67-1.671.67-1.671.671.590.08001.510.091.490.091.490.09-1.580.040.0450.0450.045-1.49-0.002-0.002-0.002-0.0021.59-1.591.691.51-1.581.711.49-1.581.711.49-1.581.71-2.530.530.50.490.49-0.84二层上柱下柱右梁左梁上柱下柱右梁左梁上柱下柱右梁左梁上柱下柱右梁左梁上柱下柱0.3220.3220.3560.2630.2370.2370.2630.2630.2370.2370.2630.2630.2370.2370.2630.3860.3070.307-168.14168.14-168.14168.14-168.14168.14-168.14168.1454.1454.1459.8639.8544.2239.8544.2239.8544.22-64.9-51.6229.9322.1122.1122.117.87-7.09-5.81-5.24-5.81-5.24-5.81-5.24-3.94-2.9-2.9-2.91.271.271.40.690.760.690.760.690.760.70.380.390.39-0.18-0.17-0.09-0.09-0.09-0.09-0.09-0.09-0.0955.4155.41-110.82190.72-7.2640.54-126.06184.73-5.3340.54-126.06184.73-5.3340.54-126.06184.73-5.3351.5318.4727.2-2.4215.51-1.7815.51-1.7815.51-17.1817.18一层上柱下柱右梁左梁上柱下柱右梁左梁上柱下柱右梁左梁上柱下柱右梁左梁上柱下柱0.3110.3450.3440.2560.2310.2570.2560.2560.2310.2570.2560.2560.2310.2570.2560.3860.3070.307-168.14168.14-168.14168.14-168.14168.14-168.14168.1452.295857.8443.214343.214343.2143-51.6228.9221.521.521.5-7.4-6.68-5.5-4.97-5.5-4.97-5.5-4.97-4.97-3.7-2.75-2.75-2.751.151.281.270.70.70.70.70.70.70.640.350.350.35-0.16-0.15-0.09-0.09-0.09-0.09-0.09-0.09-0.0953.4459.28-112.73190.14-6.8343.91-127.19184.4-5.0643.91-127.19184.4-5.0643.91-127.19184.4-51.53-51.5326.7229.64-3.421.96-2.5321.96-2.5321.96-17.18-17.18表2-16活载作用用下弯矩分配配三层上柱下柱右梁左梁上柱下柱右梁左梁上柱下柱右梁左梁上柱下柱右梁左梁上柱下柱00.9570.0430.04100.9060.0540.05300.8940.0530.05300.8940.0530.05300.944-1.621.62-3.243.24-3.243.24-3.243.241.550.07002.940.32.890.352.890.35-0.18-3.060.0350.150.180.045-1.49-0.0021.55-1.551.662.942.943.392.89-2.893.422.89-2.983.06-3.060.520.980.960.96-1.02二层上柱下柱右梁左梁上柱下柱右梁左梁上柱下柱右梁左梁上柱下柱右梁左梁上柱下柱0.3220.3220.3560.2630.2370.2370.2630.2630.2370.2370.2630.2630.2370.2370.2630.3860.3070.307-3636-3636-3636-363611.5611.5912.828.539.478.539.478.536.9513.86-11.0511.056.414.744.746.95-1.87-1.28-1.25-1.12-1.25-1.12-1.65-1.83-0.94-0.63-0.63-0.90.30.30.330.150.170.150.170.350.280.280.170.090.090.18-0.04-0.04-0.02-0.02-0.02-0.02-0.04-0.0411.8911.89-26.7940.67-1.688.68-26.9939.59-1.148.68-26.9939.56-1.146.84-30.7449.34-10.7711.333.963.96-0.562.93-0.382.93-0.382.28-3.593.78一层上柱下柱右梁左梁上柱下柱右梁左梁上柱下柱右梁左梁上柱下柱右梁左梁上柱下柱0.3110.3450.3440.2560.2310.2570.2560.2560.2310.2570.2560.2560.2310.2570.2560.3860.3070.307-3636-3636-3636-363611.1912.4212.389.259.219.259.219.2513.89-11.0511.056.194.614.616.98-1.58-1.43-1.18-1.06-1.18-1.06-1.77-1.76-0.79-0.59-0.59-0.580.260.270.270.150.150.150.150.70.70.140.080.080.17-0.04-0.06-0.02-0.02-0.02-0.02-0.04-0.0411.4512.71-24.1440.71-1.499.4-27.2340.61-1.089.4-27.2340.61-1.087.44-30.7449.35-10.7811.325.736.36-0.754.7-0.544.7-0.543.72-5.39-5.66图2-11恒载作用用下的框架弯弯矩图图2-12活载作用用下的框架弯弯矩图2.2.6.2..4梁端剪力及及柱轴力计算算梁端剪力V=Vqq+VmVm=(M左-MM右)/l柱轴力:N=V++P二层1-3跨为例VP1=VP3=1168.144kNVM1=VM3=(M左-M右)=(110.882-1900.72)/6=-113.31kkNV1=168.1-113.31==154.883kNV2=168.1+113.31==181.554kNN顶=V+P=1544.83+55.67+446.56==215.773kNN底=V+P=1544.83+55.67+44.43+446.56==220.116kN表2-17恒载作用用下梁端剪力力位置荷载引起剪力弯矩引起剪力总剪力1-33-55-66-81-33-55-66-81-33-55-66-8Vq1Vq3Vq3Vq5Vq5Vq6Vq6Vq8Vm1Vm3Vm3Vm5Vm5Vm6Vm6Vm8V1V3V3V5V5V6V6V8三层0000-0.02-0.02-0.02-0.02-0.020.02-0.020.02-0.050.02-0.020.02二层168.14168.14168.14168.14-13.31-9.78-9.78-9.78154.83181.45158.36177.92158.36177.92158.36177.92一层168.14168.14168.14168.14-12.9-9.54-9.54-9.54155.24181.04158.6177.68158.6177.68158.6177.68表2-18活载作用用下梁端剪力力位置荷载引起剪力弯矩引起剪力总剪力1-33-55-66-81-33-55-66-81-33-55-66-8Vq1Vq3Vq3Vq5Vq5Vq6Vq6Vq8Vm1Vm3Vm3Vm5Vm5Vm6Vm6Vm8V1V3V3V5V5V6V6V8三层0000-0.05-0.18-0.09-0.09-0.050.05-0.180.18-0.090.09-0.090.09二层27272727-2.31-2.09-2.09-3.124.6929.3124.9129.0624.9129.0923.930.1一层27272727-2.76-2.23-2.23-3.124.2429.7624.7729.2324.7729.2323.930.1表2-19恒载作用用下1柱轴力位置截面位置纵梁自重柱自重板自重柱轴力三层柱顶-0.021.4283.625.03柱底-0.021.4284.433.628.67二层柱顶154.835.6746.56215.73柱底154.835.674.4346.56220.16一层柱顶155.245.6746.56427.63柱底155.245.674.4346.56432.06表2-20恒载作用用下3柱轴力位置截面位置纵梁自重柱自重板自重柱轴力三层柱顶0.02-0.021.4283.625.03柱底0.02-0.021.4284.433.629.48二层柱顶181.54158.365.6746.56401.61柱底181.54158.365.674.4346.56406.04一层柱顶181.04158.65.6746.56797.91柱底181.04158.65.674.4346.56802.34表2-21恒载作用用下5柱轴力位置截面位置纵梁自重柱自重板自重柱轴力三层柱顶0.02-0.021.4283.625.03柱底0.02-0.021.4284.433.629.48二层柱顶177.92158.365.6746.56397.92柱底177.92158.365.674.4346.56402.42一层柱顶177.68158.65.6746.56790.93柱底177.68158.65.674.4346.56795.36表2-22恒载作用用下6柱轴力位置截面位置纵梁自重柱自重板自重柱轴力三层柱顶0.02-0.021.4283.625.03柱底0.02-0.021.4284.433.629.48二层柱顶177.92158.365.6746.56397.92柱底177.92158.365.674.4346.56402.42一层柱顶177.68158.65.6746.56790.93柱底177.68158.65.674.4346.56795.36表2-23恒载作用用下8柱轴力位置截面位置纵梁自重柱自重板自重柱轴力三层柱顶-0.021.4283.625.03柱底-0.021.4284.433.629.48二层柱顶177.925.6746.56239.65柱底177.925.674.4346.56244.03一层柱顶177.685.6746.56473.99柱底177.685.674.4346.56478.42表2-24活载作用用下1,3柱轴力位置1柱(边柱)/kNN3柱(中柱)/kNN板重柱轴力板重柱轴力三层-0.05-0.050.05-0.18-0.13二层24.6913.538.1429.3124.9113.567.59一层24.2413.575.8829.7624.7713.5135.62表2-25活载作用用下5,6柱轴力位置5柱(中柱)/kNN6柱(中柱)/kNN板重柱轴力板重柱轴力三层0.18-0.090.090.09-0.09-0.130二层29.0924.9113.567.5929.0923.913.566.49一层29.2324.7713.5135.0929.2323.913.5133.12表2-26活载作用用下8柱轴力位置1柱(边柱)/kNN板重柱轴力三层0.090.09二层30.113.543.69一层30.113.587.292.2.7内力力组合2.2.7.1框架梁内力力组合对于本设计,取梁梁端和跨中三三分点作为梁梁承载力设计计的控制截面面。因此,梁梁的最不利内内力组合为::梁端截面:-Mmmax、Vmax梁跨中截面:Mmmax图2-13地震左来来,右来时的的内力组合简简图有震组合时M左=MGE±ME,,M右=MGE±mMEM1/3=pl-22/3M左左-1/3M右,M2/3=pll-2/3M右-1/3M左活载按楼层的折减减系数为2-3层取0.85以二层梁1,3为为例M13=1.2266.79)++1.34..78=-1155.288kN·mmM31=1.2400.67)++1.39..45=-2265.544kN·mm表2-27梁内力组组合楼层位置荷载类型无震组合有震组合内力恒载eq\o\\ac(○,1)活载eq\o\\ac(○,2)地震荷载eq\\o\ac((○,3)1.2eq\oo\ac(○,1)+1.4eqq\o\aac(○,2)1.35eq\\o\ac((○,1)+1.199eq\oo\ac(○,2)1.2(eq\\o\ac((○,1)+0.5eqq\o\aac(○,2))±1.33eq\oo\ac(○,3)3层1右M-1.59-1.551.27-4.08-3.67-1.18-4.49V-0.02-0.050.58-0.09-0.080.703左M-1.69-1.662.19-4.35-3.91-0.18-5.87V0.020.050.580.090.080.803右M-1.58-2.342.54-5.17-4.430.00-6.60V-0.02-0.050.79-0.09-0.080.975左M-1.71-3.392.54-6.80-5.63-0.79-7.38V0.020.050.790.090.081.085右M-1.58-2.892.54-5.94-4.97-0.33-6.93V-0.02-0.050.85-0.09-0.08-1.156左M-1.71-3.422.54-6.84-5.66-0.81-7.40V0.020.050.850.090.081.156右M-1.58-2.892.54-5.94-4.97-0.33-6.93V-0.02-0.050.85-0.09-0.081.048左M-1.71-3.422.54-6.84-5.66-0.81-7.40V0.020.050.850.090.081.152层1右M-110.82-26.79-4.78-170.49-175.86-155.28-142.84V154.8324.692.37220.36233.22203.693左M-190.72-40.67-9.44-285.80-297.33-265.54-241.00V181.4529.312.37258.77273.68238.413右M-126.06-26.99-9.44-189.06-196.63-179.74-155.20V158.3624.913.45224.91238.20209.465左M-184.73-39.56-11.24-277.06-288.15-260.03-230.80V177.9229.093.45254.23268.70235.445右M-126.06-26.99-11.24-189.06-196.63-182.08-152.85V158.3624.913.75224.91238.20209.856左M-184.73-39.56-11.24-277.06-288.15-260.03-230.80V177.9229.093.75254.23268.70235.836右M-126.06-30.74-11.24-194.31-200.31-184.33-155.10V158.3623.903.75223.49237.21209.248左M-184.73-49.34-11.24-290.75-297.74-265.89-236.67V177.9230.103.75255.64269.69236.441层1右M-112.73-24.14-6.16-169.07-175.84-157.77-141.75V155.2424.243.02220.22233.33204.753左M-190.14-40.71-11.94-285.16-296.58-268.11-237.07V181.0429.763.02258.91273.57239.033右M-127.19-27.23-11.94-190.75-198.39-184.49-153.45V158.6024.774.33225.00238.38210.815左M-184.40-40.61-14.03-278.13-288.74-263.88-227.41V177.6829.234.33254.14268.51236.385右M-127.19-27.23-14.03-190.75-198.39-187.20-150.73V158.6024.774.68225.00238.38211.266左M-184.40-40.61-14.03-278.13-288.74-263.88-227.41V177.6829.234.68254.14268.51236.836右M-127.19-30.74-14.03-195.66-201.83-189.31-152.84V158.6023.904.68223.78237.53210.748左M-184.40-49.34-14.03-290.36-297.29-269.12-232.65V177.6830.104.68255.36269.37237.35*注:表中弯矩单位位为kN·m,剪力单位位为kN2.2.7.1框架柱内力力组合框架柱取每层柱顶顶和柱底两个个控制截面表2-281柱柱内力组合1柱内力组合表楼层位置内力荷载类别无震组合有震组合恒载eq\o\\ac(○,1)活载eq\o\\ac(○,2)地震荷载eq\\o\ac((○,3)1.2eq\oo\ac(○,1)+1.4eqq\o\aac(○,2)1.35eq\\o\ac((○,1)+1.199eq\oo\ac(○,2)1.2(eq\\o\ac((○,1)+0.5eqq\o\aac(○,2))±1.33eq\oo\ac(○,3)3层柱顶M1.671.55-1.274.343.771.284.59N5.03-0.05-0.586.476.745.266.76柱底M-20.06-5.511.33-33.79-32.48-25.65-29.10N8.67-0.05-0.5811.2011.669.6211.122层柱顶M55.9412.41-3.5190.1087.6870.0179.14N215.7338.14-2.95333.85328.61277.93285.59柱底M-82.13-17.622.87-131.44-128.14-105.40-112.86N220.1638.14
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 通辽 耕地合同
- 天车工续签合同述职报告
- 2025年山东货运从业资格考试技巧和方法
- 2025年东营货运上岗证考试题库
- 《欣赏高山流水》课件
- 《高血压的诊治进展》课件
- 商业中心泳池翻新协议
- 合同执行监控工具
- 信息安全协议样本
- 污水处理厂扩建临时围墙施工协议
- 2023年注册城乡规划师考试:城乡规划相关知识历年真题汇编(共388题)
- 2024年小区居民活动中心建设实施方案
- 工地柴油供油三方合同范本
- (工作计划)非物质文化遗产保护方案
- 艺术概论智慧树知到答案2024年海南师范大学
- 中国蚕丝绸文化智慧树知到答案2024年浙江大学
- 2024年贵州事业单位真题
- 困难或解决坚持不懈的作文800字
- 人教版《劳动教育》五上 劳动项目五《设计制作海报》教学设计
- 七年级道法上册第一学期期末综合测试卷(人教版 2024年秋)
- 预应力混凝土管桩(L21G404)
评论
0/150
提交评论