1第一章
人工心肺机
HEART-LUNGMACHINE
07X207J21第一章
人工心肺机
HEART-LUNGMAC2本章主要内容人工心肺机及发展情况体外循环工作原理血泵(滚柱泵、离心泵)氧合器(鼓泡式、膜式)热交换系统主要参数及监护装置2本章主要内容人工心肺机及发展情况3人工心肺机:实施体外循环灌注的机器心内直视手术OPEN-HEARTSURGERY时人工心肺机代替了人体心脏的泵血功能及人体肺脏的气体交换功能Definition:人工心肺机定义3人工心肺机:实施体外循环灌注的机器Definition:人4Surgicalproceduresinwhichcardiopulmonarybypassisused
CoronaryarterybypasssurgeryCardiacvalverepairand/orreplacement(aorticvalve,mitralvalve,tricuspidvalve,pulmonicvalve)Repairoflargeseptaldefects(atrialseptaldefect,ventricularseptaldefect,atrioventricularseptaldefect)Transplantation(hearttransplantation,lungtransplantation,heart-lungtransplantation)Repairofsomelargeaneurysms(aorticaneurysms)bulgeinartery动脉瘤Pulmonarythromboendarterectomy血栓去除:Inthoracicsurgery,apulmonarythromboendarterectomy,PTE,isanoperationthatremovesorganizedclottedblood(thrombus)fromthepulmonaryarteries.Pulmonarythrombectomy:Athrombectomy血栓去除istheexcisionofanabnormalordangerousthrombus(bloodclot).4Surgicalproceduresinwhich5第一节体外循环发展简史人工心肺机(Heartlungmachine):体外循环装置Extra-CorporealCirculationBypassCirculation5第一节体外循环发展简史人工心肺机(Heartlung6心脏内腔手术的手术环境心脏直视手术:即打开胸腔、切开心脏并暂时阻断上、下腔静脉血流向右心房的流动,使心脏内处于无血状态。通常对生命体而言,静脉血流停止时间不得超过3-4分钟,否则将因缺氧而造成死亡。6心脏内腔手术的手术环境心脏直视手术:即打开胸腔、切开心脏并7低温法应用于简单的心脏手术动物实验表明:将动物的体温降低,心脏的血流能暂时切断一个较长的时间而不致引起组织缺氧。低温法在临床上可应用于简单的心脏手术,获得成功。低温法缺点:1、产生心律紊乱,手术失败,造成死亡;2、血液阻断时间不能超过10分钟,短短的10分钟内不可能进行复杂的心脏手术。7低温法应用于简单的心脏手术动物实验表明:将动物的体温降低,8人工心肺机发展的各阶段Legallis
于1812年提出:体内或体外任何脏器,都可用体外循环来维持生存,明确提出了人工循环的概念18世纪末和19世纪初的一些生理学家进行的实验证实了此论点的正确性。1828年Key利用静脉灌注法,使处于死亡中的肌肉恢复了应激性1848年Loebell作了体外灌注肾脏的尝试1848-1858年Brown-Sequard认识到要用氧合血液灌注脏器,他们灌注的离体动物的头能保持某些神经反射。8人工心肺机发展的各阶段Legallis于1812年提出:9人工心肺机发展的各阶段1885年VonFrey及Gruder制成第一套人工心肺机,将血液以薄膜形式分布在旋转的圆筒上完成血液氧合(表面暴露式),并作了离体器官灌注
9人工心肺机发展的各阶段1885年VonFrey及Grud10人工心肺机发展的各阶段1890年Jacobe用手间歇地挤压放在动脉端的橡皮囊,使其产生波动血流灌注,并用动物肺进行氧合1910年Hooks研究了搏动性血液对肾脏的作用,强调了灌注中脉压的重要性10人工心肺机发展的各阶段1890年Jacobe用手间歇地挤11人工心肺机发展的各阶段1916-1918年先后从动物的心脏和肝脏提取肝素,1936年达到在人身上应用的程度。A、B、O血型的发现,推动了体外循环研究工作的进展,使之进入更高的实验阶段1930年Tepebukuu通过多次动物实验,认为有可能应用体外循环的方法,以维持心肺功能1933年Banerott采用人工血泵和同种肺脏来维持动物体内的血流循环11人工心肺机发展的各阶段1916-1918年先后从动物的心12人工心肺机发展的各阶段1937年Gibbon在短暂阻断犬的肺动脉期间,用人工心肺机进行体外循环维持生命,引起医学界的广泛重视1944年Ko1ff及Berk发现血在盘卷型人工肾中被氧合,因而,设计了聚乙烯毛细管盘卷型膜式氧合器12人工心肺机发展的各阶段1937年Gibbon在短暂阻断犬13人工心肺机发展的各阶段第一例真正的临床:1953年Gibbon利用垂屏式氧合器和滚压式泵进行体外循环,为1例房间隔缺损患者成功地进行了手术修补,从而使心脏外科进入了一个新的阶段1956年美国、瑞典、英国和日本等国家相继在临床开展了心内直视手术,至1957年体外循环便在世界各地广泛开展13人工心肺机发展的各阶段第一例真正的临床:1953年Gib14我国人工心肺机发展情况1956年上海胸科医院和上海医疗器械厂协作设计了滚压式血泵和鼓泡式氧合器1957年制成第一台国产人工心肺机、先后于西安和上海开展了体外循环的动物实验1958年6月西安第四军医大学苏鸿熙用人工心肺机成功为6岁男孩施行室间隔缺损直视修补术58年上海胸科医院应用国产人工心肺机,在体外循环下成功为1例先天性肺动脉瓣狭窄患者进行了矫治术14我国人工心肺机发展情况1956年上海胸科医院和上海医疗器15我国人工心肺机发展情况上械厂先后研制成Ⅰ型人工心肺机(垂屏式氧合器)和Ⅱ型人工心肺机(转碟式氧合器)80年代,上海、广州先后召开了两次全国体外循环设备技术交流会,对体外循环器械和灌注技术的发展起了积极的推动作用国外新型鼓泡氧合器的蓬勃发展,我国上海、天津、广州、西安和长春也先后试制成新型的鼓泡式氧合器,并成功地应用于临床15我国人工心肺机发展情况上械厂先后研制成Ⅰ型人工心肺机(垂16膜式氧合器1958年,面积为25m2的膜式氧合器在临床为成人进行气体交换1957年发现硅橡胶膜对氧和二氧化碳有特别高渗透性,其生物相容性好,促进了适用于临床常规使用的膜式氧合器的发展和商品化膜式氧合器已由25m2,减少到2.5m2。微孔Teflon膜(聚四氟乙烯)或空心聚丙烯微纤维,仅0.8m2的交换面积,气体交换效果远远超过了硅橡胶膜,能满足成人气体交换。16膜式氧合器1958年,面积为25m2的膜式氧合器在临床为17离心泵(灌注用)离心血泵:出现于60年代作用原理:利用离心力作为动力,驱使血液流动特点:创伤小、安全可靠、操作简便17离心泵(灌注用)离心血泵:出现于60年代18第二节体外循环原理18第二节体外循环原理19XF-4A型
人工心肺机19XF-4A型
人工心肺机20上械厂人工心肺机20上械厂人工心肺机21工作原理将上下腔静脉或右心房的静脉血通过管道引出,流入氧合器(即人工肺)进行氧合,再经过血泵(人工心脏),将氧合后的血液输入动脉系统,以维持机体在循环阻断时的生理功能。如此血液不经过自体的心肺进行氧合和组织灌注的过程,称为心肺转流(心肺旁路),亦称为体外循环。21工作原理将上下腔静脉或右心房的静脉血通过管道引出,22
泵血功能:用人工心肺机来维持心脏泵血功能
气体交换功能:用人工心肺机来维持肺脏的气体交换功能,给术者提供一个心脏停搏状态下安静无血的手术野,进行心脏及血管的手术治疗人工心肺机的作用22泵血功能:用人工心肺机来维持心脏泵血功能人工心肺机23人工心肺机基本设备血泵及其调控仪氧合器(人工肺)热交换系统动、静脉插管及管道血液回收及过滤装置监测装置等
23人工心肺机基本设备血泵及其调控仪24人体自身的血液循环24人体自身的血液循环25循环回路07j325循环回路07j326循环回路1O2-MINUSSIDEO2-POSITIVESIDE排空吸引26循环回路1O2-MINUSSIDEO2-POSITIV27动脉泵循环回路227动脉泵循环回路2282829血泵07X3血泵的主要作用是:代替心室的搏出功能、手术中失血的回吸、心脏停搏液的灌注一台完整的体外循环人工心肺机系统应由4~5个泵头(pumphead)以及其它装置设施共同组成29血泵07X3血泵的主要作用是:代替心室的搏出功能、30血泵及控制面板图血泵血泵控制部分30血泵及控制面板图血泵血泵控制部分31血泵分类按结构可分为:指压式泵、往复式泵、滚柱式泵和离心泵等。按其使用的目的分为:
动脉泵、静脉泵、吸引泵和灌注泵31血泵分类按结构可分为:32滚柱泵滚柱泵构成:泵头、泵控制面板、电气传动装置32滚柱泵滚柱泵构成:33泵头的功能传动装置:蜗杆蜗轮、皮带轮、低速电机传动方式:电机旋转运动通过(蜗杆蜗轮、皮带轮、或直接)传入泵中心轴,带动与中心泵轴相连接的两个自行运转的滚柱,在大于半圆形的泵槽内作旋转滚动,推动血液向前流动。33泵头的功能传动装置:蜗杆蜗轮、皮带轮、低速电机34血泵图34血泵图35主轴传动机构35主轴传动机构36泵头的相关问题流向、流量、流速、泵压、管夹、泵槽、泵盖、手动装置36泵头的相关问题流向、流量、流速、泵压、37流向滚柱与泵管的接触应为闭合式,以保证单向血流。较好的泵头不仅可使血流作正向流动,还可由操作控制进行反向流动。37流向滚柱与泵管的接触应为闭合式,以保证单向血流。38血液流向图血泵主轴38血液流向图血泵主轴39流量流量应有较大的范围,一般在0~6000ml/min,便可满足各种体重的灌注(co的概念)。泵要求在一定阻力范围内不改变流量,在低流量和高流量时均应稳定。
07J439流量流量应有较大的范围,一般在0~6000ml/min40流速泵管内径的粗细、泵管弹性、泵槽直径、泵的转速及泵管的出入口大小,均会影响血流通过的速度和血液破坏的程度。在高流量时,泵速和流量呈线性关系。40流速泵管内径的粗细、泵管弹性、泵槽直径、泵的转速及泵管41泵压要求:无过度挤压、无反流,取决于①滚柱和泵槽之间可调的精密度;②泵管壁厚薄均匀,误差小。41泵压要求:无过度挤压、无反流,取决于42调节滚柱张紧度42调节滚柱张紧度43管夹泵管夹固定泵管:既不改变泵管内径又能夹紧泵管,防止在滚柱的反复推动下产生滑移而影响血液灌注泵管固定夹:固定准确、操作简单、使用方便。43管夹泵管夹固定泵管:既不改变泵管内径又能夹紧泵管,防止44管夹图44管夹图45泵槽内壁一般为优弧半圆形或圆形要求内壁光滑无毛疵。无须密闭,易于清洗和擦拭开口角210度,为什么?45泵槽内壁一般为优弧半圆形或圆形46泵盖泵盖:泵运转中起保护作用,防止液体或异物溅入泵内损伤泵管。泵盖要求:透明、便于观察滚柱运转情况。有的泵盖有安全保护装置,在泵头启动运转时,揭盖则泵停止运转。46泵盖泵盖:泵运转中起保护作用,防止液体或异物溅入泵内损47血泵的结构分析47血泵的结构分析48手动装置手动装置作用:停电时继续运转维持循环。方向:滚柱泵的手摇柄一般仅能逆时针方向转动(为什么?同步齿形带又如何?)48手动装置手动装置作用:停电时继续运转维持循环。49控制面板一般的心肺机血泵上的控制装置为:电源开关、流量旋钮、流量显示、转速显示、管径选择、指示灯、反向转流开关、搏动控制开关49控制面板一般的心肺机血泵上的控制装置为:50按键式或触摸式开关。有的泵为保证安全防止错误操作,进行双指按压触摸启动。电源开关均配有保险装置,以防电压不稳时将泵烧坏电源开关50按键式或触摸式开关。有的泵为保证安全防止错误操作,进行双51一般顺时针方向为增大流量在同等流量时,各泵头流量旋钮旋转的弧度不同,灌注师应了解熟悉所使用的旋钮,以便灵活操作流量旋钮51一般顺时针方向为增大流量流量旋钮52一般机内电脑计算流量是以硅橡胶泵管或聚乙烯塑料管的内径为标准,每转搏出的量与转速的乘积即为每分钟的流量(相当于CO计算,补充计算公式)但两种相同内径的泵管,由于其弹性和管壁不同,实际流量可不同。流量显示/转速显示52一般机内电脑计算流量是以硅橡胶泵管或聚乙烯塑料管的内径为53转速显示转速显示可以间接地显示流量流量或转速:一般可由选择开关同时控制和显示53转速显示转速显示可以间接地显示流量54管径选择不同管径(内径)的泵管在同样转速下,其流量不同。因此,在使用时,应根据实际应用的泵管口径将选择旋钮指向所用的型号。管径有英制和公制两种。54管径选择不同管径(内径)的泵管在同样转速下,其流量不同。55指示灯
电源指示灯,有的机上还有转向或转速指示灯。指示灯往往与开关合并在一起。55指示灯电源指示灯,有的机上还有转向或转速指示灯。56反向转流开关一些心肺机具有反向旋转滚柱的功能为了防止误操作,在开关上增加了保护措施。注意:反向运转时,将流量旋钮调至零,关闭正向流量开关后再启动反向开关,同时调节流量旋钮56反向转流开关一些心肺机具有反向旋转滚柱的功能57搏动控制装置07j5带有搏动性能的泵具有搏动控制开关。在启动搏动开关之前,根据情况选择搏动延迟时间和搏动比率以及触发型式等。应注意:在非搏动与搏动之间的转换时流量的改变,尤其在由搏动改为非搏动时,流量增加,谨防泵空贮血室。57搏动控制装置07j5带有搏动性能的泵具有搏动控制开关。在58心肺机系统除基本组合外,还附加一系列的监测系统。泵头不仅可用于平流灌注,还可进行搏动灌注。监测系统可监测小气泡、血位、出现情况报警或停泵。有计时、测温、热交换水箱等附属设备58心肺机系统除基本组合外,还附加一系列的监测系统。泵头不仅59离心泵(灌注泵)工作原理离心泵泵头的磁性后室与带有磁性装置的驱动马达相互磁性连接;驱动马达高速旋转,带动泵内结构高速旋转,产生涡流和离心力,推动血液前进。59离心泵(灌注泵)工作原理离心泵泵头的磁性后室与带有磁性装60两种常用的离心泵:Bio-Medicus离心泵Delphin离心泵60两种常用的离心泵:Bio-Medicus离心泵61Bio-medical离心泵泵头61Bio-medical离心泵泵头62Isoflow离心泵泵头62Isoflow离心泵泵头63离心泵流量传感器的传感方式超声法:Delphin离心泵的传感器是通过换能器发射超声信号到达红细胞后,再折回到接收器,多普勒计通过对流速有关的超声信号反馈,确定其血流速度电磁法:Bio-Mid和Isoflow离心泵的传感器均为电磁性传感器。当血流通过时的磁场变化而测得血流量63离心泵流量传感器的传感方式超声法:Delphin离心泵的64离心泵滚柱泵血液破坏;压力形成;流量反应;气泡传输;灵活性;安全性;流量传感方式;操作;费用。特点比较64离心泵65血液破坏的比较离心泵和滚柱泵
对血液破坏程度不同,在转流超过6小时具有统计意义,16小时后离心泵的溶血显著小于滚柱泵转流40h,两种离心泵溶血性无显著差异Bio-Med和Delphin泵对血液损害方面差别:2、4、6L/min三种流量中,Bio-Med的血浆游离血红蛋白小于Delphin泵2、4L/min两种流量中,血小板计数Delphin泵略大于Bio-Med泵65血液破坏的比较离心泵和滚柱泵对血液破坏程度不同,在转流66压力形成的比较离心泵属非阻闭性,故其最大正压的产生受到限制。如Delphin泵,最大转速并钳闭其输出管时,所产生的最大压力仅为93kPa(700mmHg),该压力不足以使动脉泵管崩脱。66压力形成的比较离心泵属非阻闭性,故其最大正压的产生受到限67压力形成的比较对滚柱泵管:钳闭其输出端,则可能使泵管崩脱或破裂压力损伤:离心泵限制过高压力的特点,可避免损伤。如当动脉插管内血流撞击动脉壁时,滚柱泵则按其设置的流量持续灌注,过大的压力可能导致主动脉壁的损伤,而离心泵则不会产生损伤67压力形成的比较对滚柱泵管:钳闭其输出端,则可能使泵管崩脱68血流量比较离心泵为非阻闭性,流量随循环路径和人体循环阻力变化。同样转速下,体循环阻力的不同,流量可有200-400ml/min的变化;当阻力升高时,流量适当地降低;阻力降低时,流量又适当地升高。灌注师能较好地了解病人的情况,及时给予调整和处理;滚柱泵对阻力变化无任何反应。68血流量比较离心泵为非阻闭性,流量随循环路径和人体循环阻力69气泡传输比较07X4离心泵不会将大量气体泵入体内。泵头血流入口处为涡流中心,压力较低,进入的少量气体可储存在内滚柱泵一旦空气进入时,则不可避免地泵入循环路径,产生气栓的危险
69气泡传输比较07X4离心泵不会将大量气体泵入体内。泵头血70灵活性比较离心泵(包括马达)体积小,具有移动性,使用方便,可架置在病人身旁,充分缩短循环路径,既减少了异物界面,又可在较高流量下,不用或少用肝素滚柱泵泵头与控制部分连为一体,循环路径长,必须肝素化70灵活性比较离心泵(包括马达)体积小,具有移动性,使用方便71安全性比较离心泵内壁光滑,血液破坏小,不产生过高的压力和防止泵入大量气泡的特点,大大提高了灌注的安全性滚柱泵则有因泵管磨损或压力过高等因素产生泵管毛刺、颗粒脱落、破裂、崩脱和泵入空气的危险71安全性比较离心泵内壁光滑,血液破坏小,不产生过高的压力和72流量传感方式比较Delphin离心泵的流量传感器方式为超声多普勒、非侵入性重复使用的探头,准确度在10%以内。Bio-Med离心泵传感方式为侵入性一次性使用的电磁流量探头,需手工校正调零。滚柱泵则由机内电脑通过计算滚柱转速与泵管内容量的乘积而间接得到。
72流量传感方式比较Delphin离心泵的流量传感器方式为超73操作和费用比较操作:离心泵本身操作简单、安全。但因其非阻闭性的特点,在某些操作观念上与滚柱泵有很大的不同费用:离心泵头均为一次性使用,其消耗品费用远高于泵管。因此,在使用上,除考虑离心泵的优点,还应考虑经济因素73操作和费用比较操作:离心泵本身操作简单、安全。但因其非阻74第三节氧合器氧合器(Oxygenator):将进入其内的静脉血中的二氧化碳排除,使氧分压升高而成为动脉血的一种人工装置。74第三节氧合器氧合器(Oxygenator):75人体肺的基本情况人体肺:肺泡、毛细血管构成的高效气体交换器官。人体肺有3亿个肺泡。肺泡总面积60~80甚至200m2实际上,具有巨大表面积、又对气体高度通透性的肺泡、毛细血管是肺部气体完成交换的重要保证。75人体肺的基本情况人体肺:肺泡、毛细血管构成的高效气体交换76氧合器型式氧合器按设计原理可分为三种类型:血幕式、鼓泡式、膜式目前临床上常用鼓泡式和膜式氧合器76氧合器型式氧合器按设计原理可分为三种类型:血幕式77膜式氧合器77膜式氧合器78膜式氧合器78膜式氧合器79鼓泡式氧合器
通过发泡后再去泡而达到氧合目的。为了增加气体与血液的接触面,气体以气泡的形式直接注入血液中,气体的交换位于气泡的表面。如1ml气体变为12μl的气泡,109个气泡,表面积达4830cm2,增加了气体交换的面积氧合器气泡越多,气泡越小,氧合效果越好。79鼓泡式氧合器通过发泡后再去泡而达到氧合目的。80材料氧合器外壳:非一次性使用多为有机玻璃;一次性使用的多为聚乙稀、聚碳酸脂、聚苯乙稀等。氧合器内芯:目前最常用的为聚氨脂海棉、尼龙网或涤纶微孔滤网。发泡装置(气体分散器):钛、聚乙稀、有机玻璃或玻璃等。80材料氧合器外壳:非一次性使用多为有机玻璃;一81分类根据质地不同可分为袋式、桶式根据气泡分散性能分为:中泡、微泡。根据氧合能力分为:大、中、小号81分类根据质地不同可分为袋式、桶式82鼓泡式氧合器工作原理鼓泡式氧合器的功能可分为:
氧合、消泡、过滤、贮血和变温。82鼓泡式氧合器工作原理鼓泡式氧合器的功能可分为:83鼓泡式(BO)氧合器的原理气体分散器83鼓泡式(BO)氧合器的原理气体分散器84氧合氧合部分是气体交换的主要场所。氧合指氧气通过气体分散器(微孔结构),与回流到发泡室内的静脉血进行充分混合的过程。84氧合氧合部分是气体交换的主要场所。85气体分散器、氧合能力气体分散器:为钛粒高温热合而成,孔径大小不等,仅允许气体通过而液体和血不易通过。影响氧合效果的因素:①气泡形成的大小和数量;②氧合室的容积大小和长度;③应用的氧分压;④氧气在血液中搅拌的能力;⑤氧合器的扩散能力85气体分散器、氧合能力气体分散器:为钛粒高温热合而成,孔径86消泡消泡是静脉血与氧气混合形成气泡后再进行消除的过程,也是氧合器的关键部分之一。86消泡消泡是静脉血与氧气混合形成气泡后再进行消除的过程,也87消泡剂、材料材料消泡剂:常用硅油消泡剂。可将硅油与乙醚混匀后,均匀地喷洒在消泡物上。消泡材料:聚胺脂泡沫海绵、不锈钢丝或尼龙丝网等,最常用的为聚胺脂泡沫。87消泡剂、材料材料消泡剂:常用硅油消泡剂。可将硅油与乙醚混88与消泡有关的问题消泡场所消泡材料去沫剂涂抹消泡部分与贮血室连接消泡的性能88与消泡有关的问题消泡场所89消泡场所:要求应该允许具有一定流速(流量)的经过氧合的泡沫血通过的能力消泡材料应具有一定的面积,使泡沫血均匀通过89消泡场所:要求应该允许具有一定流速(流量)的经过氧合的泡90消泡材料消泡材料:尤其是聚胺脂泡沫海绵的孔径对血流阻力有一定影响,特别是当孔径过小且去沫剂涂层厚或不均匀时,易使血液贮留在氧合室内90消泡材料消泡材料:尤其是聚胺脂泡沫海绵的孔径对血流阻力有91去(泡)沫剂去沫剂涂抹过多,因血流冲击易脱落,形成微油滴,当无良好的过滤系统时,有产生栓塞的危险91去(泡)沫剂去沫剂涂抹过多,因血流冲击易脱落,形成微油滴92消泡部分与贮血室连接/消泡性能当消泡部分与贮血室连接不严密时,易使气泡进入贮血室,微气泡易随血液泵入到患者的体内,有形成气栓的危险消泡的性能随其流量增大和时间的延迟而降低92消泡部分与贮血室连接/消泡性能当消泡部分与贮血室连接不严93过滤对氧合器收集的血液再泵入体内时进行过滤,是防止机体微栓塞的重要环节之一。理想的过滤应当既能有效地滤过血液中的微气泡和其它颗粒物质,又对血液成分无损害。93过滤对氧合器收集的血液再泵入体内时进行过滤,是防止机体94过滤材料过滤网材料:国内常采用锦纶筛网,40-60µm。亦有用尼龙或涤纶织物等过滤网应包裹在去沫海绵之外并保证一定的过滤面积;低阻力,能使重力引流保持通畅,又能尽快地滤过以保证灌注流量94过滤材料过滤网材料:国内常采用锦纶筛网,40-60µm。95滤过作用减少脑和神经系统、肺等重要脏器栓塞的并发症;进一步增加消泡功能,延迟微气泡通过时间。95滤过作用减少脑和神经系统、肺等重要脏器栓塞的并发症;96贮血
鼓泡式氧合器的最后部分均为贮血室,用以储存去泡后的血液(即氧合过的动脉血)。在动脉贮血库内储存一定量的血液对体外循环灌注是一种安全保障。96贮血鼓泡式氧合器的最后部分均为贮血室,用以储存去泡后的97贮血器97贮血器98贮血器98贮血器99贮血室要求:
进入贮血室内较大的气泡能在输出前浮出。通过贮血室的血流应平稳,尽量减少湍流。灌注流量较高时,在贮血室内的血液亦应较多。99贮血室要求:进入贮血室内较大的气泡能在输出前浮出。100鼓泡式氧合器要求总结减少氧气与血液直接接触造成血红蛋白变性;血液接触面要十分光滑;材料应具有高度稳定性和良好的血液相容性;具有良好的氧气和二氧化碳的交换性能;合理的构型、尽可能一次性使用;安装、操作和控制简便,且易消毒灭菌100鼓泡式氧合器要求总结减少氧气与血液直接接触造成血红蛋白101膜式氧合器膜式氧合器(MO)是现今最接近人体生理状况的一种氧合器。其气体交换是通过一层可透气的高分子膜进行的。其特点是气血不直接接触仿生性较好,目前在临床得到越来越广泛的应用101膜式氧合器膜式氧合器(MO)是现今最接近人体生理状况的102膜式氧合器102膜式氧合器103膜式氧合器的材料
外壳:聚丙烯及聚碳酸脂等。膜:有聚丙烯、聚四氟乙烯、硅橡胶等。最常用的为聚丙烯。膜的材料条件:生理毒性小,血液相容性好;氧传送快,二氧化碳弥散好;抗张力,不易渗透或破裂。103膜式氧合器的材料外壳:聚丙烯及聚碳酸脂等。104膜式氧合器的类型根据基本结构分为:无孔膜型(非中空纤维式)微孔膜型(折叠膜式、中空纤维膜式)根据血流路径不同分为:血走中空纤维内和外两种104膜式氧合器的类型根据基本结构分为:105中空纤维膜式氧合器气体交换部分由许多根中空纤维组成,有1~7万根不等。纤维数量和长短则根据膜的透气率及所需的氧合面积来确定。血从纤维外通过的阻力和跨膜压差小,气体交换性能好。在减轻血液损伤和提高气体交换能力的同时,又降低了血与异物接触的表面积和预充量。105中空纤维膜式氧合器气体交换部分由许多根中空纤维组成,有106氧合原理
07X5气血不直接接触。气体通过很薄的膜向血中弥散,这层膜就象肺内的血气屏障,只能让气体自由通过而不允许液体(血液)渗透106氧合原理07X5气血不直接接触。气体通过很薄的膜107气体交换
07J6MO的氧气和二氧化碳输送率取决于:膜的表面积膜的性能、取决于材料的性能膜内两种气体的弥散性和溶解度107气体交换07J6MO的氧气和二氧化碳输送108热交换系统
体外循环热交换系统的二个部分:直接与血液接触而执行变温功能的变温器为变温器提供冷、热水源的驱动装置(变温水箱)。108热交换系统体外循环热交换系统的二个部分:109内部结构109内部结构110变温变温是对体外循环中血液降复温的部分。目前较先进的氧合器变温部分都与其它部分组合为一体,这样既可达到变温目的又不增加预充血量。变温材料:不锈钢或环氧树脂涂层的铝管变温装置多置于氧合器的静脉端或在氧合过程中110变温变温是对体外循环中血液降复温的部分。111变温器111变温器112变温器112变温器113变温器影响热交换器变温效能的因素有:①有效热交换面积;②原材料的导热性;③血和水的温差;④血和水流的方向及流速;⑤血流阻力。113变温器影响热交换器变温效能的因素有:114变温器种类体外循环所使用的血液变温器种类很多,依据其设计及应用的不同而分为:分离式血液变温器与其它部件相结合的变温器114变温器种类体外循环所使用的血液变温器种类很多,依据其设115变温水箱变温水箱:提供足够水流量。全自动变温水箱具有自动制冷、制冰、加温、温度监测及显示、温控报警等多项功能。115变温水箱变温水箱:提供足够水流量。116监测系统06X4心电图监测血压监测(动脉压、中心静脉压及左房压)血气及电解质监测体温监测血液平面监测气泡探测器应急电源(双重电源)116监测系统06X4心电图监测117产品介绍产品介绍117产品介绍产品介绍118XF—4A型人工心肺机XF—4A型人工心肺机是天津市医疗器械研究所研制的。其各项指标符合国家标准,在国内处于领先水平,部分指标达到国际水平。该机采用高级防锈材料,结构可分体、组合,一般配备有四个平卧式双滚柱滚压泵,体积小巧。主要用于各种手术及急救时体外循环和局部转流118XF—4A型人工心肺机XF—4A型人工心肺机是天津市医119血泵特点血泵结构设计合理,体积小,精度高,操作简便,兼容性好。运转平稳、可靠、噪音低、血液破坏小控制电路设有多重保护措施,独特的管道夹可固定任何管径的泵管,泵头设有安全锁装置。119血泵特点血泵结构设计合理,体积小,精度高,操作简便,兼120主要技术指标转速调节范围:0-250rpm,实际最低转速为0.3rpm流量显示范围:0-9.99升/分显示选择范围:φ8、φ10、φ12输入电压:DC24V功率:<200W120主要技术指标转速调节范围:0-250rpm,实际最低转121121122HeartLungMachineLungHeartMachine,ExtracorporealCirculationMachine,OxygenatorBypassMachine,HeartLungBypassMachine,PumpOxygenator122HeartLungMachineLungHear123HeartLungMachineDuringanopen-heartsurgery(suchasvalveorbypasssurgery
),theheart-lungmachineisusedtotakeoverthefunctionsoftheheartandlungs.Alsoknownasacardiopulmonarybypassmachine,itallowsthesurgeontocarefullystoptheheartwhilethevitalorganscontinuetoreceivebloodandoxygen.Whenpatientsareontheheart-lungmachine,verydelicateworkcanbeperformedbysurgeonswithoutinterferencefrombleedingortheheart’spumpingmotion.123HeartLungMachineDuringan124HeartLungMachineWhenfirstusedsuccessfully
inhumansin1955,themachinewasarevolutionarypieceofequipment.Today,theheart-lungmachineisusedinabout1millioncardiacsurgerieseveryyear,includingsurgeriestothecoronary
arteries
,heartvalvesandotherstructuresoftheheart.Theheart-lungmachinehasaverylowcomplicationrate,approaching1percentforcertainsurgeries.124HeartLungMachineWhenfirs125HeartLungMachineNewermedicaltechnologyisbeingdevelopedthatmaysomedayreplacetheheart-lungmachineinsomecircumstances.Thesetechnologiesincludesystemsthatallowsurgeonstooperateonabeatingheart,withoutuseoftheheart-lungmachine.Knownasoff-pumpsurgery,thisisusedwhensurgeonsareoperatingonthecoronaryarteries.125HeartLungMachineNewermed126Aboutheart-lungmachinesDuringanopen-heartsurgery(suchasvalveorbypasssurgery),theheart-lungmachinetakesoverthefunctionsoftheheartandlungs.Alsoknownasacardiopulmonarybypassmachine,itallowsthehearttocanbecarefullystoppedanddrainedofblood.Surgeonscanthenoperateinablood-free,quietsurgicalfield.Theheart-lungmachineallowssurgeonstoperformcomplicatedsurgerieswithouttheinterferenceofabeatingheart.126Aboutheart-lungmachinesDu127Aboutheart-lungmachinesTheheart-lungmachinebasicallyconsistsofapump(toreplacetheheart)andabubbleoxygenator(toreplacethelungs).Actingasamechanicalheartandlungs,itkeepsoxygen-richbloodflowingthroughoutthebodyafterthepatient’shearthasbeencarefullystopped.127Aboutheart-lungmachinesTh128Aboutheart-lungmachinesInaprocesscalledperfusion,themachinereceivesthepatient’sblood,removesthecarbondioxideandotherwasteproducts,addsoxygen,warms(orcools)thebloodandpumpsitbackthroughthebody.128Aboutheart-lungmachinesIn129Aboutheart-lungmachinesCoolingthebloodlowersbodytemperature.Thishelpsprotectthebody'sorganswhiletheheart-lungmachineisinuse.Afterthesurgeryiscompleted,theheartisrestarted,theheart-lungmachineisstoppedandthemachineisdisconnectedfromthepatient.129Aboutheart-lungmachinesCo130Aboutheart-lungmachinesTheheart-lungmachinecanperformothertasks.Forexample,itcandirectlydelivermedicationsintotherecirculatedblood.Itcanalsominimizebloodlossbyvacuumingupandrecirculatinganybloodthatmaygetintothesurgicalfield.130Aboutheart-lungmachinesTh131Aboutheart-lungmachinesThefirststepinusingaheart-lungmachineduringopen-heartsurgeryistogivethepatientadrugcalledheparin,whichisapowerfulanticoagulant.Heparinreducestheblood’sabilitytoclot,reducingtheriskofclotsformingintheheart-lungmachineandwithinthetubesplacedintheheart.131Aboutheart-lungmachinesTh132Aboutheart-lungmachinesOncethemedicationhastakeneffect,atube(cannula)fromtheheart-lungmachineisplacedintheupper-rightchamberoftheheart(therightatrium),whichreceivesoxygen-poorbloodfromthebody.132Aboutheart-lungmachinesOn133Aboutheart-lungmachinesAnothercannulaisplacedintheaorta,alargearterythatcarriesoxygen-richbloodfromthehearttotherestofthebody.Bysettingupthemachineinthisway,oxygen-poorblooddrainsintothemachine,receivesfreshoxygenandisreturnedtotheaortatobecarriedtotherestofthebody.133Aboutheart-lungmachinesAn134Aboutheart-lungmachinesOncethemachineisfunctioning,thesurgeoncancarefullystoptheheartwithmedicationsinordertoperformthenecessarysurgery.Apatientmayremainontheheart-lungmachineforseveralhours,thoughsurgeonstypicallytrytolimittheamountoftime(when)patientsareonbypass.134Aboutheart-lungmachinesOn135Aboutheart-lungmachinesWhenthesurgeryiscomplete,thesurgeonwillrestarttheheart.Oncethesurgicalteamissatisfiedthattheheartisbeatingstronglyagain,thetubesareremovedfromtherightatriumandtheaorta.Toreversetheeffectsoftheheparingivenatthebeginningoftheprocess,thepatientwillbeadministeredanothermedicationcalledprotamine.135Aboutheart-lungmachinesWh136Aboutheart-lungmachinesThroughoutthisprocess,theheart-lungmachineisoperatedbyaperfusionist,oneofseveralmedicalspecialistsonhandintheoperatingroomduringopen-heartsurgery.Whiletheheartisstoppedandthemachineisworking,theperfusionistcontinuallymonitorsbloodpressure
,bloodoxygenlevels,carbondioxidelevels,bloodtemperatureandbreathing136Aboutheart-lungmachinesTh13707j7THEEND13707j7THEEND138第一章
人工心肺机
HEART-LUNGMACHINE
07X207J21第一章
人工心肺机
HEART-LUNGMAC139本章主要内容人工心肺机及发展情况体外循环工作原理血泵(滚柱泵、离心泵)氧合器(鼓泡式、膜式)热交换系统主要参数及监护装置2本章主要内容人工心肺机及发展情况140人工心肺机:实施体外循环灌注的机器心内直视手术OPEN-HEARTSURGERY时人工心肺机代替了人体心脏的泵血功能及人体肺脏的气体交换功能Definition:人工心肺机定义3人工心肺机:实施体外循环灌注的机器Definition:人141Surgicalproceduresinwhichcardiopulmonarybypassisused
CoronaryarterybypasssurgeryCardiacvalverepairand/orreplacement(aorticvalve,mitralvalve,tricuspidvalve,pulmonicvalve)Repairoflargeseptaldefects(atrialseptaldefect,ventricularseptaldefect,atrioventricularseptaldefect)Transplantation(hearttransplantation,lungtransplantation,heart-lungtransplantation)Repairofsomelargeaneurysms(aorticaneurysms)bulgeinartery动脉瘤Pulmonarythromboendarterectomy血栓去除:Inthoracicsurgery,apulmonarythromboendarterectomy,PTE,isanoperationthatremovesorganizedclottedblood(thrombus)fromthepulmonaryarteries.Pulmonarythrombectomy:Athrombectomy血栓去除istheexcisionofanabnormalordangerousthrombus(bloodclot).4Surgicalproceduresinwhich142第一节体外循环发展简史人工心肺机(Heartlungmachine):体外循环装置Extra-CorporealCirculationBypassCirculation5第一节体外循环发展简史人工心肺机(Heartlung143心脏内腔手术的手术环境心脏直视手术:即打开胸腔、切开心脏并暂时阻断上、下腔静脉血流向右心房的流动,使心脏内处于无血状态。通常对生命体而言,静脉血流停止时间不得超过3-4分钟,否则将因缺氧而造成死亡。6心脏内腔手术的手术环境心脏直视手术:即打开胸腔、切开心脏并144低温法应用于简单的心脏手术动物实验表明:将动物的体温降低,心脏的血流能暂时切断一个较长的时间而不致引起组织缺氧。低温法在临床上可应用于简单的心脏手术,获得成功。低温法缺点:1、产生心律紊乱,手术失败,造成死亡;2、血液阻断时间不能超过10分钟,短短的10分钟内不可能进行复杂的心脏手术。7低温法应用于简单的心脏手术动物实验表明:将动物的体温降低,145人工心肺机发展的各阶段Legallis
于1812年提出:体内或体外任何脏器,都可用体外循环来维持生存,明确提出了人工循环的概念18世纪末和19世纪初的一些生理学家进行的实验证实了此论点的正确性。1828年Key利用静脉灌注法,使处于死亡中的肌肉恢复了应激性1848年Loebell作了体外灌注肾脏的尝试1848-1858年Brown-Sequard认识到要用氧合血液灌注脏器,他们灌注的离体动物的头能保持某些神经反射。8人工心肺机发展的各阶段Legallis于1812年提出:146人工心肺机发展的各阶段1885年VonFrey及Gruder制成第一套人工心肺机,将血液以薄膜形式分布在旋转的圆筒上完成血液氧合(表面暴露式),并作了离体器官灌注
9人工心肺机发展的各阶段1885年VonFrey及Grud147人工心肺机发展的各阶段1890年Jacobe用手间歇地挤压放在动脉端的橡皮囊,使其产生波动血流灌注,并用动物肺进行氧合1910年Hooks研究了搏动性血液对肾脏的作用,强调了灌注中脉压的重要性10人工心肺机发展的各阶段1890年Jacobe用手间歇地挤148人工心肺机发展的各阶段1916-1918年先后从动物的心脏和肝脏提取肝素,1936年达到在人身上应用的程度。A、B、O血型的发现,推动了体外循环研究工作的进展,使之进入更高的实验阶段1930年Tepebukuu通过多次动物实验,认为有可能应用体外循环的方法,以维持心肺功能1933年Banerott采用人工血泵和同种肺脏来维持动物体内的血流循环11人工心肺机发展的各阶段1916-1918年先后从动物的心149人工心肺机发展的各阶段1937年Gibbon在短暂阻断犬的肺动脉期间,用人工心肺机进行体外循环维持生命,引起医学界的广泛重视1944年Ko1ff及Berk发现血在盘卷型人工肾中被氧合,因而,设计了聚乙烯毛细管盘卷型膜式氧合器12人工心肺机发展的各阶段1937年Gibbon在短暂阻断犬150人工心肺机发展的各阶段第一例真正的临床:1953年Gibbon利用垂屏式氧合器和滚压式泵进行体外循环,为1例房间隔缺损患者成功地进行了手术修补,从而使心脏外科进入了一个新的阶段1956年美国、瑞典、英国和日本等国家相继在临床开展了心内直视手术,至1957年体外循环便在世界各地广泛开展13人工心肺机发展的各阶段第一例真正的临床:1953年Gib151我国人工心肺机发展情况1956年上海胸科医院和上海医疗器械厂协作设计了滚压式血泵和鼓泡式氧合器1957年制成第一台国产人工心肺机、先后于西安和上海开展了体外循环的动物实验1958年6月西安第四军医大学苏鸿熙用人工心肺机成功为6岁男孩施行室间隔缺损直视修补术58年上海胸科医院应用国产人工心肺机,在体外循环下成功为1例先天性肺动脉瓣狭窄患者进行了矫治术14我国人工心肺机发展情况1956年上海胸科医院和上海医疗器152我国人工心肺机发展情况上械厂先后研制成Ⅰ型人工心肺机(垂屏式氧合器)和Ⅱ型人工心肺机(转碟式氧合器)80年代,上海、广州先后召开了两次全国体外循环设备技术交流会,对体外循环器械和灌注技术的发展起了积极的推动作用国外新型鼓泡氧合器的蓬勃发展,我国上海、天津、广州、西安和长春也先后试制成新型的鼓泡式氧合器,并成功地应用于临床15我国人工心肺机发展情况上械厂先后研制成Ⅰ型人工心肺机(垂153膜式氧合器1958年,面积为25m2的膜式氧合器在临床为成人进行气体交换1957年发现硅橡胶膜对氧和二氧化碳有特别高渗透性,其生物相容性好,促进了适用于临床常规使用的膜式氧合器的发展和商品化膜式氧合器已由25m2,减少到2.5m2。微孔Teflon膜(聚四氟乙烯)或空心聚丙烯微纤维,仅0.8m2的交换面积,气体交换效果远远超过了硅橡胶膜,能满足成人气体交换。16膜式氧合器1958年,面积为25m2的膜式氧合器在临床为154离心泵(灌注用)离心血泵:出现于60年代作用原理:利用离心力作为动力,驱使血液流动特点:创伤小、安全可靠、操作简便17离心泵(灌注用)离心血泵:出现于60年代155第二节体外循环原理18第二节体外循环原理156XF-4A型
人工心肺机19XF-4A型
人工心肺机157上械厂人工心肺机20上械厂人工心肺机158工作原理将上下腔静脉或右心房的静脉血通过管道引出,流入氧合器(即人工肺)进行氧合,再经过血泵(人工心脏),将氧合后的血液输入动脉系统,以维持机体在循环阻断时的生理功能。如此血液不经过自体的心肺进行氧合和组织灌注的过程,称为心肺转流(心肺旁路),亦称为体外循环。21工作原理将上下腔静脉或右心房的静脉血通过管道引出,159
泵血功能:用人工心肺机来维持心脏泵血功能
气体交换功能:用人工心肺机来维持肺脏的气体交换功能,给术者提供一个心脏停搏状态下安静无血的手术野,进行心脏及血管的手术治疗人工心肺机的作用22泵血功能:用人工心肺机来维持心脏泵血功能人工心肺机160人工心肺机基本设备血泵及其调控仪氧合器(人工肺)热交换系统动、静脉插管及管道血液回收及过滤装置监测装置等
23人工心肺机基本设备血泵及其调控仪161人体自身的血液循环24人体自身的血液循环162循环回路07j325循环回路07j3163循环回路1O2-MINUSSIDEO2-POSITIVESIDE排空吸引26循环回路1O2-MINUSSIDEO2-POSITIV164动脉泵循环回路227动脉泵循环回路216528166血泵07X3血泵的主要作用是:代替心室的搏出功能、手术中失血的回吸、心脏停搏液的灌注一台完整的体外循环人工心肺机系统应由4~5个泵头(pumphead)以及其它装置设施共同组成29血泵07X3血泵的主要作用是:代替心室的搏出功能、167血泵及控制面板图血泵血泵控制部分30血泵及控制面板图血泵血泵控制部分168血泵分类按结构可分为:指压式泵、往复式泵、滚柱式泵和离心泵等。按其使用的目的分为:
动脉泵、静脉泵、吸引泵和灌注泵31血泵分类按结构可分为:169滚柱泵滚柱泵构成:泵头、泵控制面板、电气传动装置32滚柱泵滚柱泵构成:170泵头的功能传动装置:蜗杆蜗轮、皮带轮、低速电机传动方式:电机旋转运动通过(蜗杆蜗轮、皮带轮、或直接)传入泵中心轴,带动与中心泵轴相连接的两个自行运转的滚柱,在大于半圆形的泵槽内作旋转滚动,推动血液向前流动。33泵头的功能传动装置:蜗杆蜗轮、皮带轮、低速电机171血泵图34血泵图172主轴传动机构35主轴传动机构173泵头的相关问题流向、流量、流速、泵压、管夹、泵槽、泵盖、手动装置36泵头的相关问题流向、流量、流速、泵压、174流向滚柱与泵管的接触应为闭合式,以保证单向血流。较好的泵头不仅可使血流作正向流动,还可由操作控制进行反向流动。37流向滚柱与泵管的接触应为闭合式,以保证单向血流。175血液流向图血泵主轴38血液流向图血泵主轴176流量流量应有较大的范围,一般在0~6000ml/min,便可满足各种体重的灌注(co的概念)。泵要求在一定阻力范围内不改变流量,在低流量和高流量时均应稳定。
07J439流量流量应有较大的范围,一般在0~6000ml/min177流速泵管内径的粗细、泵管弹性、泵槽直径、泵的转速及泵管的出入口大小,均会影响血流通过的速度和血液破坏的程度。在高流量时,泵速和流量呈线性关系。40流速泵管内径的粗细、泵管弹性、泵槽直径、泵的转速及泵管178泵压要求:无过度挤压、无反流,取决于①滚柱和泵槽之间可调的精密度;②泵管壁厚薄均匀,误差小。41泵压要求:无过度挤压、无反流,取决于179调节滚柱张紧度42调节滚柱张紧度180管夹泵管夹固定泵管:既不改变泵管内径又能夹紧泵管,防止在滚柱的反复推动下产生滑移而影响血液灌注泵管固定夹:固定准确、操作简单、使用方便。43管夹泵管夹固定泵管:既不改变泵管内径又能夹紧泵管,防止181管夹图44管夹图182泵槽内壁一般为优弧半圆形或圆形要求内壁光滑无毛疵。无须密闭,易于清洗和擦拭开口角210度,为什么?45泵槽内壁一般为优弧半圆形或圆形183泵盖泵盖:泵运转中起保护作用,防止液体或异物溅入泵内损伤泵管。泵盖要求:透明、便于观察滚柱运转情况。有的泵盖有安全保护装置,在泵头启动运转时,揭盖则泵停止运转。46泵盖泵盖:泵运转中起保护作用,防止液体或异物溅入泵内损184血泵的结构分析47血泵的结构分析185手动装置手动装置作用:停电时继续运转维持循环。方向:滚柱泵的手摇柄一般仅能逆时针方向转动(为什么?同步齿形带又如何?)48手动装置手动装置作用:停电时继续运转维持循环。186控制面板一般的心肺机血泵上的控制装置为:电源开关、流量旋钮、流量显示、转速显示、管径选择、指示灯、反向转流开关、搏动控制开关49控制面板一般的心肺机血泵上的控制装置为:187按键式或触摸式开关。有的泵为保证安全防止错误操作,进行双指按压触摸启动。电源开关均配有保险装置,以防电压不稳时将泵烧坏电源开关50按键式或触摸式开关。有的泵为保证安全防止错误操作,进行双188一般顺时针方向为增大流量在同等流量时,各泵头流量旋钮旋转的弧度不同,灌注师应了解熟悉所使用的旋钮,以便灵活操作流量旋钮51一般顺时针方向为增大流量流量旋钮189一般机内电脑计算流量是以硅橡胶泵管或聚乙烯塑料管的内径为标准,每转搏出的量与转速的乘积即为每分钟的流量(相当于CO计算,补充计算公式)但两种相同内径的泵管,由于其弹性和管壁不同,实际流量可不同。流量显示/转速显示52一般机内电脑计算流量是以硅橡胶泵管或聚乙烯塑料管的内径为190转速显示转速显示可以间接地显示流量流量或转速:一般可由选择开关同时控制和显示53转速显示转速显示可以间接地显示流量191管径选择不同管径(内径)的泵管在同样转速下,其流量不同。因此,在使用时,应根据实际应用的泵管口径将选择旋钮指向所用的型号。管径有英制和公制两种。54管径选择不同管径(内径)的泵管在同样转速下,其流量不同。192指示灯
电源指示灯,有的机上还有转向或转速指示灯。指示灯往往与开关合并在一起。55指示灯电源指示灯,有的机上还有转向或转速指示灯。193反向转流开关一些心肺机具有反向旋转滚柱的功能为了防止误操作,在开关上增加了保护措施。注意:反向运转时,将流量旋钮调至零,关闭正向流量开关后再启动反向开关,同时调节流量旋钮56反向转流开关一些心肺机具有反向旋转滚柱的功能194搏动控制装置07j5带有搏动性能的泵具有搏动控制开关。在启动搏动开关之前,根据情况选择搏动延迟时间和搏动比率以及触发型式等。应注意:在非搏动与搏动之间的转换时流量的改变,尤其在由搏动改为非搏动时,流量增加,谨防泵空贮血室。57搏动控制装置07j5带有搏动性能的泵具有搏动控制开关。在195心肺机系统除基本组合外,还附加一系列的监测系统。泵头不仅可用于平流灌注,还可进行搏动灌注。监测系统可监测小气泡、血位、出现情况报警或停泵。有计时、测温、热交换水箱等附属设备58心肺机系统除基本组合外,还附加一系列的监测系统。泵头不仅196离心泵(灌注泵)工作原理离心泵泵头的磁性后室与带有磁性装置的驱动马达相互磁性连接;驱动马达高速旋转,带动泵内结构高速旋转,产生涡流和离心力,推动血液前进。59离心泵(灌注泵)工作原理离心泵泵头的磁性后室与带有磁性装197两种常用的离心泵:Bio-Medicus离心泵Delphin离心泵60两种常用的离心泵:Bio-Medicus离心泵198Bio-medical离心泵泵头61Bio-medical离心泵泵头199Isoflow离心泵泵头62Isoflow离心泵泵头200离心泵流量传感器的传感方式超声法:Delphin离心泵的传感器是通过换能器发射超声信号到达红细胞后,再折回到接收器,多普勒计通过对流速有关的超声信号反馈,确定其血流速度电磁法:Bio-Mid和Isoflow离心泵的传感器均为电磁性传感器。当血流通过时的磁场变化而测得血流量63离心泵流量传感器的传感方式超声法:Delphin离心泵的201离心泵滚柱泵血液破坏;压力形成;流量反应;气泡传输;灵活性;安全性;流量传感方式;操作;费用。特点比较64离心泵202血液破坏的比较离心泵和滚柱泵
对血液破坏程度不同,在转流超过6小时具有统计意义,16小时后离心泵的溶血显著小于滚柱泵转流40h,两种离心泵溶血性无显著差异Bio-Med和Delphin泵对血液损害方面差别:2、4、6L/min三种流量中,Bio-Med的血浆游离血红蛋白小于Delphin泵2、4L/min两种流量中,血小板计数Delphin泵略大于Bio-Med泵65血液破坏的比较离心泵和滚柱泵对血液破坏程度不同,在转流203压力形成的比较离心泵属非阻闭性,故其最大正压的产生受到限制。如Delphin泵,最大转速并钳闭其输出管时,所产生的最大压力仅为93kPa(700mmHg),该压力不足以使动脉泵管崩脱。66压力形成的比较离心泵属非阻闭性,故其最大正压的产生受到限204压力形成的比较对滚柱泵管:钳闭其输出端,则可能使泵管崩脱或破裂压力损伤:离心泵限制过高压力的特点,可避免损伤。如当动脉插管内血流撞击动脉壁时,滚柱泵则按其设置的流量持续灌注,过大的压力可能导致主动脉壁的损伤,而离心泵则不会产生损伤67压力形成的比较对滚柱泵管:钳闭其输出端,则可能使泵管崩脱205血流量比较离心泵为非阻闭性,流量随循环路径和人体循环阻力变化。同样转速下,体循环阻力的不同,流量可有200-400ml/min的变化;当阻力升高时,流量适当地降低;阻力降低时,流量又适当地升高。灌注师能较好地了解病人的情况,及时给予调整和处理;滚柱泵对阻力变化无任何反应。68血流量比较离心泵为非阻闭性,流量随循环路径和人体循环阻力206气泡传输比较07X4离心泵不会将大量气体泵入体内。泵头血流入
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 数据分析在招聘中的应用试题及答案
- 场景营销方法的试题及答案
- 软件资格初级2025年应试技巧试题及答案
- 计算机初级资格技能测评试题及答案
- 二零二五年度海洋资源开发合作保证金合同模板
- 二零二五年度城乡居民养老保险协议书
- 2025年度物流行业增资扩股及运输服务协议
- 2025年度汽车4S店车辆运输配送合同
- 二零二五年度物流线路承包与智能物流机器人研发合同
- 二零二五年度健康体检销售折扣及健康管理合同
- 食品行业安全监管与溯源方案
- 书籍设计出版合同范本
- 2025年法律文书考试试题及答案
- 2025年安庆医药高等专科学校单招职业适应性考试题库完美版
- 2024年东营市技师学院招聘工作人员考试真题
- 智能科学与技术专业建设思路
- 2023年全国高考体育单招考试英语卷试题真题(含答案详解)
- 2024 ESC慢性冠脉综合征指南解读(全)
- 2024年湖北省中考地理生物试卷(含答案)
- 第一次月考测试卷(试题)-2023-2024学年人教版六年级数学下册
- 2024年江苏旅游职业学院高职单招(英语/数学/语文)笔试历年参考题库含答案解析
评论
0/150
提交评论