




版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
常见故障排除工具(一)commandSwitch#10.1.1.100Type
esc sequence
to
abort.Sending
5,
100-byte
ICMP
Echos
to
10.1.1.100,
timeout
is
2
seconds:!!!!!Success
rate
is
100
percent
(5/5),
round-trip
min/avg/max
=
1/203/1007
msC:\>ing[192.0.43.10]
with
32
bytes
of
data:Replyfrom192.0.43.10:bytes=32time=107msTTL=243Replyfrom192.0.43.10:bytes=32time=107msTTL=243Replyfrom192.0.43.10:bytes=32time=137msTTL=243Replyfrom192.0.43.10:bytes=32time=107msTTL=243statistics
for
192.0.43.10:Packets:
Sent
=
4,
Received
=
4,
Lost
=
0
(0%
loss),Approximate
round
trip
times
in
milli-seconds:Minimum
=
107ms, um
=
137ms,
Average
=
114msInterconnecting
CiscoNetworking
Devices,
Part
1(ICND1)
v2.0常见故障排除工具(二)Interconnecting
CiscoNetworking
Devices,
Part
1(ICND1)
v2.0netSwitch1#
net
10.1.20.1Trying
10.1.20.1
...
OpenSwitch2>介质问题—铜缆铜缆可能会出现以下问题:线路会受损电磁干扰流量模式变化安装新设备Interconnecting
CiscoNetworking
Devices,
Part
1(ICND1)
v2.0介质问题—光纤光缆可能会出现以下问题:折弯损耗:弯曲半径过小导致光的纤维损坏–光纤芯或包覆层弯曲小于临界角漏光熔纤损耗Interconnecting
CiscoNetworking
Devices,
Part
1(ICND1)
v2.0排除交换机媒介故障(一)Interconnecting
CiscoNetworking
Devices,
Part
1(ICND1)
v2.0排除交换机媒介故障(二)Interconnecting
CiscoNetworking
Devices,
Part
1(ICND1)
v2.0检查接口状态:Switch#show
interface
FastEthernet0/1FastEthernet0/1
is
up,
line
protocol
is
upHardware
is
Fast
Ethernet,
address
is
0022.91c4.0e01
(bia
0022.91c4.0e01)MTU
1500
bytes,
BW
100000
Kbit,
DLY
100
usec,<output
omitted>接口状态检验(一)过多的噪波:许多CRC错误存在–检查电缆损坏和正确的长度并且寻找噪波来源过多的
:一般是双工不匹配造成的配置全双工Interconnecting
CiscoNetworking
Devices,
Part
1(ICND1)
v2.0接口状态检验(二)Switch#show
interface
FastEthernet0/1FastEthernet0/1
is
up,
line
protocol
is
upHardware
is
Fast
Ethernet,
address
is
0022.91c4.0e01
(bia0022.91c4.0e01)MTU
1500
bytes,
BW
100000
Kbit,
DLY
100
usec,<output
omitted>2295197
packets
input,
305539992
bytes,
0
no
bufferReceived
1925500
broadcasts,
0
runts,
0
giants,
0
throttles3
input
errors,
3
CRC,
0
frame,
0
overrun,
0
ignored0
watchdog,
68
multicast,
0
pause
input0
input
packets
with
dribble
condition
detected3594664
packets
output,
436549843
bytes,
0
underruns1935
output
errors,1790
collisions,10
interface
resets0
unknown
protocol
drops0
babbles,
135
late
collision,
0
deferred<output
omitted>Displays
interface
status
and
statisticsInterconnecting
CiscoNetworking
Devices,
Part
1(ICND1)
v2.0端口问题(一)Interconnecting
CiscoNetworking
Devices,
Part
1(ICND1)
v2.0端口问题大多跟双工和速率有关Duplex-related
issues
result
from
a
mismatch
in
duplex
settings:Speed-related
issues
result
from
a
mismatch
in
speed
settings:端口问题(二)双工相关问题实例:一端双工,一端半双工导致双工不匹配一端全双工,一端自动协商:–如果协商失败则工作在半双工,导致双工不匹配一端全双工,一端自动协商:如果协商失败,将工作在半双工两端都工作在半双工,没有双工不匹配的情况Interconnecting
CiscoNetworking
Devices,
Part
1(ICND1)
v2.0端口问题(三)Interconnecting
CiscoNetworking
Devices,
Part
1(ICND1)
v2.0的双工问题实例:两端全设置为自动协商:一端全双工失败,另外一端半双工失败Example:A
Gigabit
Ethernet
interface
defaults
tofull
duplex,
while
a10/100defaultsto
halfduplex.两端全设置为自动协商:两端如果协商失败,则都工作在半双工模式两端协商为半双工,没有双工不匹配的问题端口问题(四)Interconnecting
CiscoNetworking
Devices,
Part
1(ICND1)
v2.0速率相关问题实例:一端设置为10M,另外一端设置100M,造成速率不匹配一端设置为高速,另外一端设置为自动协商:如果协商失败,则恢复使用最佳速率两端都设置为自动协商:如果协商失败,两端都恢复使用最低速率两端都使用最低速率,则没有速率不匹配的问题端口问题故障(一)Interconnecting
CiscoNetworking
Devices,
Part
1(ICND1)
v2.0%CDP-4-DUPLEX_MISMATCH:
duplex
mismatch
discovered
on
FastEthernet0/1
(nothalf
duplex)Show
interface
f0/1Troubleshooting
duplex-related
issues:端口问题故障 (二)Interconnecting
CiscoNetworking
Devices,
Part
1(ICND1)
v2.0Switch#show
interfaces
FastEthernet
0/1FastEthernet0/1
is
up,
line
protocol
is
up
(connected)Hardware
is
Fast
Ethernet,
address
is
001e.147c.6f01
(bia001e.147c.6f01)MTU
1500
bytes,
BW
100000
Kbit/sec,
DLY
100
usec,reliability
255/255,
txload
1/255,
rxload
1/255Encapsulation
ARPA,
loopback
not
setKeepalive
set
(10
sec)Full-duplex,
100Mb/s,
media
type
is
10/100BaseTXinput
flow-control
is
off,
outputflow-control
is
unsupportedARP
type:
ARPA,
ARP
Timeout
04:00:00Last
input
00:00:28,
output
00:00:01,
output
hang
neverLast
clearing
of
"show
interface"
counters
neverInput
queue:
0/75/0/0
(size/max/drops/flushes);
Total
output
drops:
0Queueing
strategy:
fifoOutput
queue:
0/40
(size/max)Displays
duplex
and
speed
statisticsVLAN排错(一)Interconnecting
CiscoNetworking
Devices,
Part
2(ICND2)
v2.0VLAN排错(二)SW1#show
mac
address-table
interface
FastEthernet
0/1Mac
Address
TableTypePortsFa0/1Fa0/1Vlan Mac
Address10
000c.296a.a21c10
000f.34f9.9181Total
Mac
Addresses
forDYNAMICDYNAMICthis
criterion:
2Interconnecting
CiscoNetworking
Devices,
Part
2(ICND2)
v2.0查看MAC地址表VLAN排错(三)SW1#show
interfaces
FastEthernet
0/1
switchportName:
Fa0/1Switchport:
EnabledAdministrative
Mode:
static
accessOperational
Mode:
static
accessAdministrative
Trunking
Encapsulation:
dot1qOperational
Trunking
Encapsulation:
nativeNegotiation
of
Tr
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 高三下学期《遇见最美的时光我的人生满意度》主题班会课件
- 汽车使用与维护 课件 项目三 空调系统的使用与维护
- 2025年环保速冻喷剂项目可行性研究报告
- 江苏航运职业技术学院《食品类专业写作》2023-2024学年第一学期期末试卷
- 浙江省杭州市杭州第二中学2025年高三下第一次摸底考试历史试题试卷含解析
- 那曲市2024-2025学年初三下学期期末考试物理试题仿真(A)卷含解析
- 低压电器 课件 单元三 项目二 任务二 掌握三相异步电动机点动控制线路
- 无锡科技职业学院《统计学原理含统计软件应用》2023-2024学年第二学期期末试卷
- 江苏工程职业技术学院《ADR实务》2023-2024学年第二学期期末试卷
- 汕头大学《钢与组合结构设计》2023-2024学年第二学期期末试卷
- 加油站施工施工组织设计方案
- 应急停水停电培训资料
- 传染病防治知识和技能培训计划
- 《EPS处理表面氧化铁皮技术要求 》
- 【MOOC】书法鉴赏-浙江传媒学院 中国大学慕课MOOC答案
- 足球场运动草坪全年养护计划
- (高清版)DBJ52∕T 017-2014 回弹法检测山砂混凝土抗压强度技术规程
- 现代化背景下企业档案管理创新路径
- 《幼儿教育政策与法规》课件-单元4 幼儿园的保育和教育
- 2024年私募基金争议解决研究报告之一:私募基金管理人谨慎勤勉义务之边界探析-国枫研究院
- 环卫设施设备更新实施方案
评论
0/150
提交评论