版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1、Lenovo Storwize系列存储Scope of OEM Storage Agreement Lenovo will use HVEC for all products; IBM will use AAS for all products Relationship is non-exclusive for both Lenovo and IBMAvailable on Day 1* Availability of V5000 / V7000 is TBD in Nov/Dec 2014DiskIBM Entry Storage ProductsEXP2500Storwize V3700
2、/ V3500LTO tape drives and 1U enclosureStorwize V3500(China only)Storwize V7000Storwize V7000 UnifiedStorwize V3700Storwize V5000TS2900TS3100TS3200TS2250TS2260LTO TapeIBM Midrange Storage ProductsStorwize V5000 / V7000 *IBM TS2900 tape autoloader and TS3100/TS3200 tape librariesKey Items Regarding O
3、EM StorageThe OEM Storage product we sell and ship as Lenovo will be the same as what IBM sellsOnly the packaging and part numbers will be differentLenovo Logo readiness will be in late 3Q or 4Q ProductV3500 : Synnex, all RRV3700 : HCF, all RRV5000: DCT, case by case SBOV7000: Open, case by case SBO
4、Route to MarketOEM Storage pricing process will be similar to how we price storage todayEntry StorageUp front pricing from IBM should allow Lenovo to cover delegated bids and most special bidsOn an exception basis, Lenovo may need to request special bid pricing from IBMPricingPricing from IBM on V50
5、00/V7000 will likely require Lenovo to request special bid pricing on most sales opportunitiesMidrange StorageStorwize系列存储技术概览Storwize 存储家族微码一致、功能一致、界面一致Storwize V7000 Unified(MT2076+2073)Flex V7KSVCMT 2076全新 V7000 1:2 4C512GB/1056disks全新 V7000 1:2 1C 128GB/480disksMT 2076全新 V7000 1:2 2C256GB/960dis
6、ksMT 2076Storwize V7000 4C64GB/960disksMT 2076Storwize V7000 1C16GB/240disksStorwize V500016/32GB 960disksV3500/V3700 (MT 2071/2072)8GB/24disks ; 8-16GB/240disksNEWNEWNEW2013年7月(大中华区)提高中型企业灵活性Storwize V5000制订了中端存储新标准:Storwize V70002010年10月Unified StorageActive Cloud EngineStorwize V7000 Unified2011年
7、10月Storwize V3500(仅大中华区)2012年8月Storwize V3700Flex System V70002012年11月Storwize V3700增强特性SVC压缩性能Easy Tier与压缩容量与VM可扩展性Global Active Cloud Engine2012年6月62015 LENOVO INTERNAL. All rights reservedStorwize准确交付功能与价值V3500: 2U, 24个驱动器(2.5” SAS)V3500 : 2U, 12个驱动器(3.5” SAS)2U高机柜式机箱Storwize V3500概述 基于Storwize的创
8、新架构设计,提供简便性和易用性 极为紧凑的封装:区区2U空间最多可容纳12个3.5”或24个2.5” 驱动器 每个控制器对通过2个主机接口卡提供8个8Gbps FC端口(可选) 每个控制器对支持4个1Gbps iSCSI端口 8 GB缓存(双控制器):镜像、后备电池软件功能:精简配置、单向数据迁移、Flashcopy(最大64个目标)最多可容纳24个驱动器,支持混合使用不同类型的驱动器(不支持SSD):3.5英寸SAS NL:2 TB 和 3 TB 7.2K rpm2.5英寸SAS:146 GB, 300 GB 15K rpm300 GB, 600 GB 和 900 GB 10K rpm 50
9、0 GB, 1 TB 7.2K rpm SAS NL 72.5-in3.5-in2U机柜中最多包含12个LFF(3.5英寸)或24个SFF(2.5英寸)驱动器控制机柜:双活控制器(Active/Active)标配8 GB缓存(每控制器4 GB),可选择升级到16 GB标配1Gb/s iSCSI主机端口,可选择升级到8Gb/s FC或10Gb/s iSCSI/FCoE扩展机柜:多达9个扩展机柜连接到一个控制机柜(7.3微码开始),最大240块硬盘在同一机柜中混合不同尺寸的驱动器和HDD/SSD支持RAID 0、1、5、6和10(可以通过Capacity Magic来换算可用容量和裸容量)冗余、可
10、热插拔组件(例如电源和风扇等)包含FlashCopy许可(默认最多64个FlashCopy目标)82015 LENOVO INTERNAL. All rights reservedStorwize V3700概述V3700支持FC/iSCSI/FCoE/SAS多种连接方式iSCSI口SAS口连主机SAS口连扩展柜Optional cardStorwize V5000概述产品机箱可在仅仅2U空间中容纳最多12个LFF(3.5”)或24个SFF(2.5”)硬盘控制机箱双主-主控制器与硬盘16GB标配缓存(8GB/控制器)标配支持4*1Gb iSCSI、8*8Gb FC和4*SAS主机端口扩展机箱最
11、多9个扩展机箱(11月发布新版本支持19个扩展机箱)最多480个SFF或240个LFF硬盘,提供最大可达960TB的存储容量群集系统最多能够提供2PB存储容量RAID级别0、1、5、6、10冗余的热插拔组件(如电源和风扇)可选软件Easy Tier、外部虚拟化、远程镜像及闪速拷贝Storwize V7000 1:2概述基础架构至关重要:全新IBM Storwize V7000 1:2硬件加速式IBM实时压缩TM技术可将成本降低近一半4显著提高已压缩数据的处理性能IBM压缩技术及性能保证允许您充满信心地部署系统功能强大且高可扩展2倍可扩展性最高可达4PB性能最多支持64个内核基础架构速度12Gb
12、ps SAS连接性最多支持64个FC端口8倍缓存最高可达512GB第一代V7000新二代V7000增加的倍数FC主机端口数8*8 Gb 16*8 Gb增加一倍万兆以太网端口数4*10 Gb 8*10 Gb增加一倍磁盘柜扩展口速率4*6 Gb SAS4*12 Gb SAS增加一倍缓存16GB64GB 或 128G最多增加八倍中央处理器4 核Intel Xeon6核或8 核 Intel Xeon最多增加一倍每个控制器柜支持的扩展柜数最多9个最多19个增加一倍V7000 1:2 性能、容量、效率提升2倍1:235项创新专利RACE压缩引擎LZH标准算法、随机访问技术 创新的基于实时的压缩独特的 “文
13、件感知”实时在线压缩,实现存储效率最大化透明的集成性能5倍的存储空间压缩率可高达 80%可对更多的数据进行分析大幅减少每TB容量总体成本无需对现有架构进行改变对应用系统透明无性能损失最大化缓存利用率线性增长存储效率性能架构创新无性能降低RtC如何做到RTC Engine存储CacheCacheIP 网络客户端应用服务器减少磁头移动、更好的缓存利用、更少的I/O实时压缩写入时执行压缩更少的数据写入主存储 (可减少 80%的数据) 更少的I/O减少磁盘负载实时压缩存储处理的只是压缩后的数据最大化存储缓存利用率 (近似增加5倍的缓存容量) 可以从缓存处理更多的服务器读写请求存储CPU的负荷更低 实时
14、压缩不会导致性能降低由于通过缓存、而不是磁盘提供数据,读写请求处理更快磁盘上存取的数据更少,因此磁盘的IO次数、磁头的移动次数都大大减少V7000 1:2 关键卖点实时数据压缩数据库数据个人文档数据CAD/CAM图纸虚拟机数据油气勘探类数据2倍以上的容量节省72.0%50.0%20% to60%70.0%20%40%60%80%0%压缩后容量压缩比率100%85.0%V7000 1:2实时在线压缩实际测评报告ISV NameIndustry Focus Compression Ratio Performance Improve DHCHealthcare&Medical71%10%MS SQL
15、 2014General 70%58%TJHQ-GFMIS Finance90%Keep SameHundsunSecurity86%86%JYD(嘉运达)Enterprise-ERP85%Keep SameNeusoftHealthcare-PACS42.40%Keep SameZDnetTPCC60%(est.)50%Build up V7000 1:2Partner Eco-systemV7000 1:2中端存储之王V7000 1:2(4 cluster)EMC VNX 5800EMC VNX 7600EMC VNX 8000EMC VMAX 10KBlock控制器数量82228CPU核
16、数868166最大CPU核数6412163248专用在线压缩引擎YesNoNoNoNo最大缓存数量(Block)512GB64GB128GB256GB512GB最大内置磁盘数量1056750100015001560瘦供给功能YesYesYesYesYes自动分层功能YesYesYesYesYes外部虚拟化功能Yes (90%+)NoNoNoYes本地数据克隆/快照YesYesYesYesYes在线无损压缩YesNo(后处理方式)No(后处理方式)No(后处理方式)No(后处理方式)重复数据删除NoYesYesYesNoVmware VAAIYesYesYesYesYesStorwize系列产品
17、技术规格一览表V3500V3700(New)V5000(New)V7000(New)容量12个3.5”或24个2.5”硬盘(不支持扩展柜和集群)每个控制机箱最多支持240个硬盘(最多9个扩展单元),不支持集群)每个控制机箱最多支持240个硬盘(最多9个扩展单元);每个群集系统最多支持480个硬盘(2路群集)每个控制机箱最多支持504个硬盘;每个群集系统最多支持1056个硬盘(4个群集)标准主机端口4个1Gbps iSCSI端口,6个6Gb SAS端口1Gb iSCSI, 6Gb SAS1Gb iSCSI, 6Gb SAS1Gb iSCSI, FC可选主机端口8个8Gb FC端口iSCSI 10
18、Gbps, FC, FCoEiSCSI 10Gbps, FC, iSCSI 10Gbps, FCoE缓存(双控制器)仅8GB8GB ,可升级至16GB16GB/双控制器,每个群集系统最多支持 32GB64/128GB/双控制器,每个群集系统最多支持 512GB集成的特性精简配置、Flashcopy(最大64个目标),单向数据迁移闪速拷贝(每个系统64个映像),内部虚拟化,精简调配,单向数据迁移内部虚拟化,精简调配,数据迁移,系统群集闪速拷贝(4,096个映像),内部虚拟化,精简调配,数据迁移,Easy Tier,系统群集可选特性无闪速拷贝(2040个映像),Easy Tier,远程镜像,Tur
19、bo PerformanceEasy Tier,远程镜像,外部虚拟化远程镜像,外部虚拟化,实时压缩外部虚拟化否否是,可选是,可选统一存储支持否否否Storwize V7000 Unified支持NAS连接;集成了IBM Active Cloud Engine软件收费方式无按控制器按机箱按机箱支持SSD不支持支持支持支持多路径软件免费免费免费免费软件计费政策919Storwize系列存储软件功能介绍Storwize在同步/异步复制方面的兼容性从6.3版本开始,storwize系列不同产品之间支持复制功能,提供最佳投资保护V3700的第一个版本为7.1, 支持与SVC/V5000/V7000的复制
20、,功能也与其它产品相同(支持同步/异步,FC/IP等多种复制方式)如果同SVC做复制,需要将V3700的layer属性改成replicationStorwize同步复制功能(MetroMirror)基于存储的复制,可实现RPO=0(相比数据库复制,vSphere replication等方案的优势)MetroMirror理论上支持300KM,需考虑延迟带来的影响需考虑距离增加到一定程度可能需要LW SFP, DWDM, Extended Fabric许可等因素Storwize异步复制功能(Global Mirror with change volume)ChangeVolume2Primary
21、VolumeFCMapping1Reverse FCMapping1(1) For internal use cannot be manipulated like any other FC mapping (2) may not be used for host I/O & may not be used for any other Copy ServicesSecondaryVolumeChangeVolume2FCMapping1Reverse FCMapping1Primary change volume storeschanges to be sent to secondarySeco
22、ndary change volume used toprotect consistent image at secondary定期将主中心的快照变化数据传输到灾备中心循环周期:默认300秒,最小60秒新的循环周期在上一个周期完成后或数据完全复制后自动开始始终保持灾备中心有一份可用的数据(Flashcopy卷)不必按照波峰sizing链路,更节约带宽结合SANSlide技术可以更有效使用IP链路带宽HDD Arrays最新Easy Tier 3在线分层唯一全自动数据分层结合数据在线压缩80%以上的同时性能提升3倍这两个功能可以同时使用在同一个volume上,效率更高Better than on
23、e-third response timeActive Data Migrates UpLess Active DataMigrates DownFlash Arrays单向迁移功能减少数据迁移对业务的影响在线迁移可按照Migration Wizard提示的步骤完成将V3700接入SAN停止旧存储上的I/O,将旧存储上的LUN映射给V3700在V3700上为每一个旧存储映射过来的LUN创建image mode volume(对原有存储数据不做任何改变)主机上安装V3700对应的多路径软件,将V3700 image volume映射到主机为Image volume创建位于V3700内部的镜像卷,
24、数据同步期间应用可以在线迁移过程结束,旧存储可以下线存储整合V5K和V7K从中心点管理存储资源池虚拟磁盘虚拟磁盘虚拟磁盘虚拟磁盘HDSEMCNetAppIBMHPTMSOracle内置磁盘存储虚拟化通过存储资源池申请服务资源“ .现在我们可以在业务运行时进行在线变更.”英国银行支持管理所有市场主流的异构存储厂商,业界最开放将外部多个存储单元合并至单一的存储资源池不中断应用的在线改变存储资源在线压缩V7K数据库office件CAD/CAM地理信息虚拟化服务器已压缩文件,如:JPEG/ZIP30%50%72%70%80%5%压缩率平均压缩率在55%Storwize 总体高于一半的压缩结果适用场景:
25、RTC(REAL Time Compression,实时压缩)针对动态和静态的数据for Active & Inactive Data性能和压缩率经过测试,有保证基于Web的向导式GUI,支持中文易于使用的用户界面28集成的视频指导系统建议可按需链接到更多信息系统状态始终提供直观的任务流指导Storwize系列存储典型应用场景光纤交换机磁带库V3000SAN数据库服务器VMware ESX应用服务器前置系统其它功能服务器(开发测试、备份)流量均衡HALAN302015 LENOVO INTERNAL. All rights reserved构建共享存储架构VMware虚拟机架构支持NAS/NF
26、SFibreChanneliSCSIV3700DS8000V7000SVCSONASIBM具有简单易用的存储解决方案用于整合并扩展VMWare的高级软件功能 (VMotion, VM HA, DRS, Storage VMotion, & SRM).IBM在VMWare虚拟环境下的存储解决方案包括 iSCSI, FC, and NFS等所有VMWare支持的存储接口.经过验证的包括并行扩展、高可用、容灾复制等多种存储解决方案.VMWare虚拟环境下独特的IBM存储解决方案创新动力来源于 协作研发 新颖服务 端到端的IBM解决方案基于V3700复制+SRM的容灾解决方案ESX w/VMsVMwa
27、reViewESX w/VMsFC or iSCSISANFC or iSCSISANFibre Channelor IP NetworkProduction DataReplicated DataESX Server Farm3. In event of disaster, production data goes downVMwarevCenter ServerSite RecoveryManagerVMwarevCenter ServerSite RecoveryManager4. and pressing the Failover button brings up data on se
28、condary side, performing these tasks for user:VMware Site Recovery ManagerFlashCopy+FCM: 帮助客户减小备份窗口TSM ServerProductionDB2FCMFC TargetFC SourceV3700Backup nodeDB2FCM对生产环境影响最小HPC共享存储超算中心渲染农场/动漫渲染数字化油田商业智能覆盖行业GFLOPS(gigaFLOPS):每秒拾亿(=109)次的浮点运算TFLOPS(teraFLOPS):每秒一兆(=1012)次的浮点运算PFLOPS(petaFLOPS):每秒一千兆(
29、=1015)次的浮点运算EFLOPS(exaFLOPS):每秒一佰京(=1018)次的浮点运算高性能计算(HPC)理论浮点计算能力主频每CPU周期执行浮点指令次数单位物理处理器的核心数单台刀片节点的物理处理器数服务器节点数10(单位:亿次)X240 2*E5-2665 8C 2.4Ghz CPU,理论浮点计算能力=2.4*8*8*2*1*10=768(亿次)P460 2* 4.1Ghz Power7+ CPU,理论浮点计算能力=4.1*16*16*2*1*10=2099.2(亿次)管理节点Internet登陆节点登陆节点计算节点计算节点计算节点计算节点计算节点计算节点IO节点IO节点内部高速互
30、联网络存储设别异地容灾(Figure from REDP5023)并行的建立多条虚拟链路( virtual connections ),共享IP链路和地址:当等待一条虚拟链路的ACK时,另外的虚拟链路能够正常发送更多的数据包数据包丢失时,数据将会被重传根据传输的数据包数量,大小,智能的调节虚拟链路(VC)的数目,保证网络传输的最佳性能建设远程容灾系统,保证业务连续性V3700在中小制造业ERP环境的应用ERP生产系统方案描述对I/O响应要求极高的业务用SSD POOL来承载对I/O响应要求较高的业务用混合池承载对I/O响应要求不高的业务放在低速盘上利用精简配置功能应对业务部门不断增长的空间需求
31、利用TPC来监控性能、容量的使用状态SSD EnclosureHDD Enclosure V3700ERPSCMCRM其它业务报表分析BWETLBPM etcSSD only poolEasy Tier poolHDD only poolV7000实现大型企业ERP核心应用整合客户反馈系统架构高可用,无单点故障性能答复提升系统迁移快速、无风险运维简单基于Storwize的SmartCloud解决方案Lenovo方案建议小型云支持150个虚拟机4*X240+FSM+Flex V7000中型云支持500个虚拟机13*X240+FSM+V7000大型云支持1000个虚拟机27*X240+FSM+V7
32、000客户需求成熟参考架构快速部署易于扩展方案价值丰富实施案例FSM+Flex V7000+SCE,快速安装和部署cloud按需扩展基于Storwize的虚拟桌面解决方案基于SAN存储V7000/V5000/V3000+NFS服务器优点:全PureFlex解决方案,内置V7000,system data放块存储,每个用户user data映射一个NAS目录;成本适中缺点:可以扩展到一定用户规模客户需求:初期用户规模不大,后期需扩展500快速部署可管理性基于SAN存储V7000/V5000/V3000优点:全PureFlex解决方案,内置V7000,成本低缺点:不能扩展到很大用户规模客户需求:用
33、户规模100快速部署基于Storwize的大数据解决方案ConfigurationRack of 28 x240 + 2 V7000Cores (processor)336 Cores (E5-2630)Available Storage (HDD size)240TB (1TB)Drive (data / total )240 / 296Network Switches1 G8264 + 1 G8052 + 4 Pass-ThruRack of X240+Side-Car28 (x240+Side-Car), each withTwo E5-2630 2.3GHz 6-core CPU64G
34、B RAM Two 1TB 3.5” HDD (OS/app)Twelve 1TB 3.5” HDD (data)Dual-port 10GbE (data)Dual-port 1GbE (mgmt)Flex ChassisFlex ChassisFlex ChassisFlex ChassisFlex ChassisFlex ChassisV7000 EnclV7000 EnclRack of X240+V700028 x240, each withTwo E5-2630 2.3GHz 6-core CPU64GB RAM Two 1TB 3.5” HDD (OS/app)Dual-port
35、 10GbE (data)Dual-port 1GbE (mgmt)2 V7000 (1 control + 4 expansion) 240 x 1TB 2.5” HDD ConfigurationRack of 28 (x240+Side-Car) Cores (processor)336 Cores (E5-2630)Available Storage (HDD size)336TB (1TB)Drive (data / total )336 / 392Network Switches1 G8264 + 1 G8052 + 8 Pass-Thru 基于本地扩展盘的参考配置基于V7000 SAN的参考配置性能要求不高性能要求高V3000成功案例客户名称配置概述应用环境广东国税局V3500OA系统集中存储广州海监局V3700海监数据集中存储南方医科大学V3700HPC共享存储暨南大学V3500HPC共享存储梅州地税V3700备份存储福建消防V5000*2 + V3700本地存储高可用+容灾福建高速V3700路段交费集中存储V5K/V7K制造业成功案例V5K/V7K中小银行解
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 二零二四年度物业管理公司地铁保安安检服务合同2篇
- 解除股权转让协议范本
- 2024年度超市商品标签印刷合同
- 二零二四年度物流仓储服务承包合同
- 个人房屋租赁合同模板
- 二零二四年度国际贸易与合作协议
- 2024版存量房交易合同2篇
- 04版直播带货艺人合同2篇
- 2024版二建建筑项目工程验收合同
- 二零二四年度技术服务合同服务内容描述及服务期限
- 建设新型能源体系提高能源资源安全保障能力
- GB/T 22082-2024预制混凝土衬砌管片
- 2025年蛇年年度营销日历营销建议【2025营销日历】
- 盛世华诞庆祝祖国成立75周年共筑中国梦同庆国庆节课件
- 2024年二级建造师继续教育题库及答案(500题)
- 企业所得税汇算清缴申报表电子表格版(带公式-自动计算)
- 2024年“正大杯”市场调查与分析竞赛考试题库及答案
- MOOC 制造技术基础训练-北京理工大学 中国大学慕课答案
- 人教版九年级英语上册阅读理解10篇(含答案)
- 冬季作业安全技术交底
- 10KV配电室倒闸操作票
评论
0/150
提交评论