1、quarter 1part iii: quarterly check item/第三部分:季度检查表quarterly checklist for fire fighting system消防系统季度检查表noitem/检查项目inspection results 检查结果note/备注fire alarming system/火灾自动报警系统fire detectors/火灾探测器1if voltage is 24v工作电压是否正常(24v)2installation angle < 45° 安装角度小于45°3good contact with foundatio

2、n 和底座接触良好4surface clean and not obstructed 表面清洁,未被阻挡5no obstructions in 0.5m 在0.5m的范围内无障碍物6if power supply is ok 电源指示灯是否闪亮7alarm functional test 报警功能测试8signal transition and alarm function 信号传输及报警功能interaction control facilities/ 联动控制设备1heat and smoke release system functional test (auto end manual

3、mode)防排烟设备功能测试(手动及自动)semi-yearly/每半 年2fire rolling shutter functional test (auto and manual mode)防火卷帘门功能测试(手动及自动)3no obstructions under fire rolling shutter 防火卷帘门下无障碍物4fire alarming system and emergency lighting system functional test火灾事故广播及事故照明系统功能测试(手动及 自动)5no obstructions to fire emergency lighti

4、ng system 在事故照明系统周围没有障碍物阻碍视线6signal transition and alarm function 信号传输以及报警功能测试yearly/每年fire incident communication/消防通讯设备1communication with central fire control panel 消控中心与各点通讯正常fire alarm button/手动报警按钮1if fixed firmly/ 安装是否牢固2if there is enough clearance 周围绘否有足够操作空间3any damage or broken 是否有破损4if q

5、uantity enough 数量是否足够5alarm functional test 报警功能测试randomly pick 2 sets 任选两组power supply system/供电系统1auto switch function test主、备电源自动切换装置功能正常1 3 test 测试13次2backup power system recharging test 备用电源充放电试验12 test 测试12次3conjunction box/ 接线盒4no loose connection/ 接线端子连接牢固5clean surface/ 表面清洁6no damage/ 无破损a

6、uto-switch function/ 自动切换功能1non fire fighting power shut off test 强制切断非消防电源功能试验fire alarm control panel/火灾控制盘(柜)1no loose connection/ 接线端子连接牢固2clean surface/ 表面清洁3no damage/ 无破损4if there is enough clearance 周围是否有足够操作空间5if grounding well/ 是否有可靠接地6if fixed firmly/ 安装是否牢固alarm valve station functional

7、test/ 报警阀组功能测试1water pressure (bar)/ 水压(ba“meet design spec 符合设计要求2alarm functional test 水力警铃报警性能3water flow indicator functional test 水流指示器功能测试4 r presser switch functional test压力开关功能测试5fire pump start test/ 消防泵是否启动> 5min 运转大于5min6if pressure before and after valve balanced 阀站前后压差是否平衡outdoor con

8、trol valve/室外控制阀门1in the correct open-close status 开关状态止常2if valves were secured by chain or other devices 阀门是否被锁链或其他装置锁定3lubricant oil/ 是否已添加润滑油4housekeeping in valves wells 室外阀门井中是否有其他杂物5if valves were broken 阀门是否有破损indoor fire hydrant system/室内消防栓系统1no missing components消火栓、水枪、水带、消防水喉,垫圈是否齐全2no r

9、ust on surface/ 表面无锈蚀3no broken parts/ 外观无损坏,4no malfunction on alarm control 报警控制线路无故障5lubricant oil/ 润滑油已添加6pump could be start within 5min after fire alarm 5' 水泵在报警5分钟之内启动fire hydrant system/室外消防栓系统1no obstruction around fire hydrant 消防栓周围无杂物2no broken parts /消防栓外观无损坏3feed pressure is ok/ 水压符

10、合要求4no water leakage/ 消防栓不漏水malfunction elimination status/故障排除情况no.item description/悄况描述respon person 负责人completion date 完成日期inspected by/检查人 : date/日期: reviewed by/审核人 °: date/ r 期: note/说明1 25% spot checks should be conducted every quarter, all fire detectors should be covered in a yearly ba

11、se每季度抽检25%火灾探测器,每年对所安装的火灾探测器检杳一次2. visual inspection in case there is no safe access to fire detectors 在无安全通道的条件下,可采取目测检查3 should be conducted in precondition of no significant adverse impact to normal production and no damage to tested equipments 应在对生产没有不良影响和对设备没有损坏的条件进行测试。4. both alarm and signal transmission function should be checked 警报以及信号传输功能检查5. should be conducted in precondition of no damage to

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论