




版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
100MW山地光伏(渔光互补)项目质量验收范围划分表编制单位:光伏发电监理项目部二〇二四年十二月
目录一、编制说明 -2-工程编号工程名称验收单位本部分编号单位工程子单位工程分部工程子分部工程分项工程检验批施工单位勘测单位设计单位总承包单位监理单位建设单位1土建工程√√√√√DL/T5210.1表3.0.12-4~-3.0.12.7、3.0.141光伏区土建工程√√√√√DL/T5210.1表3.0.12-4~-3.0.12.7、3.0.141光伏支架基础√√√√DL/T5210.1表3.0.12-31#1阵列(地块)光伏支架基础√√√√DL/T5210.1表3.0.12-31定位及高程控制√√√DL/T5210.1表3.0.12-21定位及高程控制√√√DL/T5210.1表5.2.12混凝土预制桩施工(锤击)√√√DL/T5210.1表3.0.12-21混凝土预制桩施工(锤击)√√√DL/T5210.1表5.7.42#2方阵光伏支架基础√√√√DL/T5210.1表3.0.12-31定位及高程控制√√√DL/T5210.1表3.0.12-21定位及高程控制√√√DL/T5210.1表5.2.12混凝土预制桩施工(锤击)√√√DL/T5210.1表3.0.12-21混凝土预制桩施工(锤击)√√√DL/T5210.1表5.7.43#3方阵光伏支架基础√√√√DL/T5210.1表3.0.12-31定位及高程控制√√√DL/T5210.1表3.0.12-21定位及高程控制√√√DL/T5210.1表5.2.12混凝土预制桩施工(锤击)√√√DL/T5210.1表3.0.12-21混凝土预制桩施工(锤击)√√√DL/T5210.1表5.7.44#4方阵光伏支架基础√√√√DL/T5210.1表3.0.12-31定位及高程控制√√√DL/T5210.1表3.0.12-21定位及高程控制√√√DL/T5210.1表5.2.12混凝土预制桩施工(锤击)√√√DL/T5210.1表3.0.12-21混凝土预制桩施工(锤击)√√√DL/T5210.1表5.7.45#5方阵光伏支架基础√√√√DL/T5210.1表3.0.12-31定位及高程控制√√√DL/T5210.1表3.0.12-21定位及高程控制√√√DL/T5210.1表5.2.12混凝土预制桩施工(锤击)√√√DL/T5210.1表3.0.12-21混凝土预制桩施工(锤击)√√√DL/T5210.1表5.7.42箱式变压器基础√√√√√DL/T5210.1表3.0.12-31#1方阵变压器基础√√√√√DL/T5210.1表3.0.12-31定位及高程控制√√√DL/T5210.1表3.0.12-21定位及高程控制√√√DL/T5210.1表5.2.12挖方√√√DL/T5210.1表3.0.12-21土(石)方开挖√√√DL/T5210.1表5.3.1、表5.3.23填方√√√DL/T5210.1表3.0.12-21土方回填√√√DL/T5210.1表5.3.31混凝土垫层√√√DL/T5210.1表5.17.2-65模板√√√DL/T5210.1表3.0.12-21模板安装√√√DL/T5210.1表5.12.16钢筋√√√DL/T5210.1表3.0.12-21钢筋加工√√√DL/T5210.1表5.12.62钢筋安装√√√DL/T5210.1表5.12.87混凝土√√√DL/T5210.1表3.0.12-21混凝土原材料及拌合物√√√DL/T5210.1表5.12.92混凝土施工√√√DL/T5210.1表5.12.103混凝土外观及尺寸偏差√√√DL/T5210.1表5.12.118排油管安装√√√DL/T5210.1表3.0.12-21排油管安装√√√DL/T5210.1表5.31.162排油管防腐√√√DL/T5210.1表5.30.1~5.30.42#2方阵变压器基础√√√√DL/T5210.1表3.0.12-31定位及高程控制√√√DL/T5210.1表3.0.12-21定位及高程控制√√√DL/T5210.1表5.2.12挖方√√√DL/T5210.1表3.0.12-21土(石)方开挖√√√DL/T5210.1表5.3.1、表5.3.23填方√√√DL/T5210.1表3.0.12-24垫层√√√DL/T5210.1表3.0.12-21混凝土垫层√√√DL/T5210.1表5.17.2-65模板√√√DL/T5210.1表3.0.12-21模板安装√√√DL/T5210.1表5.12.16钢筋√√√DL/T5210.1表3.0.12-21钢筋加工√√√DL/T5210.1表5.12.62钢筋安装√√√DL/T5210.1表5.12.87混凝土√√√DL/T5210.1表3.0.12-21混凝土原材料及拌合物√√√DL/T5210.1表5.12.92混凝土施工√√√DL/T5210.1表5.12.103混凝土外观及尺寸偏差√√√DL/T5210.1表5.12.118排油管安装√√√DL/T5210.1表3.0.12-21排油管安装√√√DL/T5210.1表5.31.162排油管防腐√√√DL/T5210.1表5.30.1~5.30.43#3方阵变压器基础√√√√DL/T5210.1表3.0.12-31定位及高程控制√√√DL/T5210.1表3.0.12-21定位及高程控制√√√DL/T5210.1表5.2.12挖方√√√DL/T5210.1表3.0.12-21土(石)方开挖√√√DL/T5210.1表5.3.1、表5.3.23填方√√√DL/T5210.1表3.0.12-21土方回填√√√DL/T5210.1表5.3.34垫层√√√DL/T5210.1表3.0.12-21混凝土垫层√√√DL/T5210.1表5.17.2-65模板√√√DL/T5210.1表3.0.12-21模板安装√√√DL/T5210.1表5.12.16钢筋√√√DL/T5210.1表3.0.12-21钢筋加工√√√DL/T5210.1表5.12.62钢筋安装√√√DL/T5210.1表5.12.87混凝土√√√DL/T5210.1表3.0.12-21混凝土原材料及拌合物√√√DL/T5210.1表5.12.92混凝土施工√√√DL/T5210.1表5.12.103混凝土外观及尺寸偏差√√√DL/T5210.1表5.12.118排油管安装√√√DL/T5210.1表3.0.12-21排油管安装√√√DL/T5210.1表5.31.162排油管防腐√√√DL/T5210.1表5.30.1~5.30.44#4方阵变压器基础√√√√DL/T5210.1表3.0.12-31定位及高程控制√√√DL/T5210.1表3.0.12-21定位及高程控制√√√DL/T5210.1表5.2.12挖方√√√DL/T5210.1表3.0.12-21土(石)方开挖√√√DL/T5210.1表5.3.1、表5.3.23填方√√√DL/T5210.1表3.0.12-21土方回填√√√DL/T5210.1表5.3.34垫层√√√DL/T5210.1表3.0.12-21混凝土垫层√√√DL/T5210.1表5.17.2-65模板√√√DL/T5210.1表3.0.12-21模板安装√√√DL/T5210.1表5.12.16钢筋√√√DL/T5210.1表3.0.12-21钢筋加工√√√DL/T5210.1表5.12.62钢筋安装√√√DL/T5210.1表5.12.87混凝土√√√DL/T5210.1表3.0.12-21混凝土原材料及拌合物√√√DL/T5210.1表5.12.92混凝土施工√√√DL/T5210.1表5.12.103混凝土外观及尺寸偏差√√√DL/T5210.1表5.12.118排油管安装√√√DL/T5210.1表3.0.12-21排油管安装√√√DL/T5210.1表5.31.162排油管防腐√√√DL/T5210.1表5.30.1~5.30.45#5方阵变压器基础√√√√DL/T5210.1表3.0.12-31定位及高程控制√√√DL/T5210.1表3.0.12-21定位及高程控制√√√DL/T5210.1表5.2.12挖方√√√DL/T5210.1表3.0.12-21土(石)方开挖√√√DL/T5210.1表5.3.1、表5.3.23填方√√√DL/T5210.1表3.0.12-21土方回填√√√DL/T5210.1表5.3.34垫层√√√DL/T5210.1表3.0.12-21混凝土垫层√√√DL/T5210.1表5.17.2-65模板√√√DL/T5210.1表3.0.12-21模板安装√√√DL/T5210.1表5.12.16钢筋√√√DL/T5210.1表3.0.12-21钢筋加工√√√DL/T5210.1表5.12.62钢筋安装√√√DL/T5210.1表5.12.87混凝土√√√DL/T5210.1表3.0.12-21混凝土原材料及拌合物√√√DL/T5210.1表5.12.92混凝土施工√√√DL/T5210.1表5.12.103混凝土外观及尺寸偏差√√√DL/T5210.1表5.12.118排油管安装√√√DL/T5210.1表3.0.12-21排油管安装√√√DL/T5210.1表5.31.162排油管防腐√√√DL/T5210.1表5.30.1~5.30.42场区及地下设施√√√√√DL/T5210.1表3.0.12-4~-3.0.12.7、3.0.141场区平整√√√√√DL/T5210.1表3.0.12-31地基工程√√√√√DL/T5210.1表3.0.12-31定位及高程控制√√√DL/T5210.1表3.0.12-21定位及高程控制√√√DL/T5210.1表5.2.12挖方√√√DL/T5210.1表3.0.12-21土(石)方开挖√√√DL/T5210.1表5.3.1、表5.3.23填方√√√DL/T5210.1表3.0.12-21土方回填√√√DL/T5210.1表5.3.32道路工程√√√√DL/T5210.1表3.0.12-31场区道路√√√√DL/T5210.1表3.0.12-31路基工程√√√DL/T5210.1表3.0.12-21土方路基(3km一个检验批)√√√JTGF80/1表4.2.22填石路基√√√JTGF80/1表4.3.22基层√√√DL/T5210.1表3.0.12-21填隙碎石(矿渣)基层√√√JTGF80/1表7.9.23面层√√√DL/T5210.1表3.0.12-21级配碎(砾)石面层√√√JTGF80/1表7.8.23光伏场区围栏√√√√DL/T5210.1表3.0.12-31#1方阵光伏区围栏√√√√DL/T5210.1表3.0.12-31基础混凝土√√√DL/T5210.1表3.0.12-21混凝土材料及拌合物√√√DL/T5210.1表5.12.92混凝土施工√√√DL/T5210.1表5.12.103混凝土结构外观尺寸偏差√√√DL/T5210.1表5.12.112围栏安装√√√DL/T5210.1表3.0.12-21围栏安装√√√DL/T5210.1表5.13.192#2方阵光伏区围栏√√√√DL/T5210.1表3.0.12-31基础混凝土√√√DL/T5210.1表3.0.12-21混凝土材料及拌合物√√√DL/T5210.1表5.12.92混凝土施工√√√DL/T5210.1表5.12.103混凝土结构外观尺寸偏差√√√DL/T5210.1表5.12.112围栏安装√√√DL/T5210.1表3.0.12-21围栏安装√√√DL/T5210.1表5.13.193#3方阵光伏区围栏√√√√DL/T5210.1表3.0.12-31基础混凝土√√√DL/T5210.1表3.0.12-21混凝土材料及拌合物√√√DL/T5210.1表5.12.92混凝土施工√√√DL/T5210.1表5.12.103混凝土结构外观尺寸偏差√√√DL/T5210.1表5.12.112围栏安装√√√DL/T5210.1表3.0.12-21围栏安装√√√DL/T5210.1表5.13.193#4方阵光伏区围栏√√√√DL/T5210.1表3.0.12-31基础混凝土√√√DL/T5210.1表3.0.12-21混凝土材料及拌合物√√√DL/T5210.1表5.12.92混凝土施工√√√DL/T5210.1表5.12.103混凝土结构外观尺寸偏差√√√DL/T5210.1表5.12.112围栏安装√√√DL/T5210.1表3.0.12-21围栏安装√√√DL/T5210.1表5.13.193#5方阵光伏区围栏√√√√DL/T5210.1表3.0.12-31基础混凝土√√√DL/T5210.1表3.0.12-21混凝土材料及拌合物√√√DL/T5210.1表5.12.92混凝土施工√√√DL/T5210.1表5.12.103混凝土结构外观尺寸偏差√√√DL/T5210.1表5.12.112围栏安装√√√DL/T5210.1表3.0.12-21围栏安装√√√DL/T5210.1表5.13.193混凝土结构外观尺寸偏差√√√DL/T5210.1表5.12.1103升压站土建工程√√√√√DL/T5210.1表3.0.12-4~-3.0.12.701升压站站区平整√√√√√DL/T5210.1表3.0.12-4~-3.0.12.701站区平整√√√√√DL/T5210.1表3.0.12-301定位及高程控制√√√DL/T5210.1表3.0.12-201定位及高程控制√√√DL/T5210.1表5.2.102挖方√√√DL/T5210.1表3.0.12-201土方开挖√√√DL/T5210.1表5.3.103填方√√√DL/T5210.1表3.0.12-201土方回填√√√DL/T5210.1表5.3.202综合楼√√√√√√DL/T5210.13.0.12-4~-3.0.12.7O1地基与基础工程√√√√√√DL/T5210.1表3.0.12-3O1定位及高程控制√√√DL/T5210.1表3.0.12-2O1定位及高程控制√√√DL/T5210.1表5.2.1O2挖方√√√DL/T5210.1表3.0.12-2O1土(石)方开挖√√√DL/T5210.1表5.3.1~2O3填方√√√DL/T5210.1表3.0.12-2O1土方回填√√√DL/T5210.1表5.3.304土石方堆放√√√√√DL/T5210.1表3.0.12-201土石方堆放√√√DL/T5210.1表5.3.4O5垫层√√√DL/T5210.1表3.0.12-2O1垫层√√√DL/T5210.1表5.17.2-1~6O6基础模板√√√DL/T5210.1表3.0.12-2O1模板安装√√√DL/T5210.1表5.12.1O7基础钢筋√√√DL/T5210.1表3.0.12-2O1钢筋加工√√√DL/T5210.1表5.12.6O2钢筋安装√√√DL/T5210.1表5.12.8O8基础混凝土√√√DL/T5210.1表3.0.12-2O1混凝土原材料及拌合物√√√DL/T5210.1表5.12.9O2混凝土施工√√√DL/T5210.1表5.12.10O3混凝土结构外观及尺寸偏差√√√DL/T5210.1表5.12.1102主体结构√√√√√DL/T5210.1表3.0.12-3O1模板√√√DL/T5210.1表3.0.12-2O1现浇混凝土结构模板安装√√√DL/T5210.1表5.12.1O2钢筋√√√DL/T5210.1表3.0.12-2O1钢筋加工√√√DL/T5210.1表5.12.6O2钢筋安装√√√DL/T5210.1表5.12.8O3混凝土√√√DL/T5210.1表3.0.12-2O1混凝土原材料及拌合物√√√DL/T5210.1表5.12.9O2混凝土施工√√√DL/T5210.1表5.12.10O3混凝土结构外观及尺寸偏差√√√DL/T5210.1表5.12.11O4砖砌体工程√√√DL/T5210.1表3.0.12-2O1填充墙砌体√√√DL/T5210.1表5.11.5O3建筑装饰装修√√√√√DL/T5210.1表3.0.12-301楼面与地面√√√DL/T5210.1表3.0.12-2O1基土质量√√√DL/T5210.1表5.17.1O2垫层√√√DL/T5210.1表5.17.2-2~6O3中间层处理√√√DL/T5210.1表5.17.3-1~4O4防水层√√√DL/T5210.1表5.17.1O5面层√√√DL/T5210.1表5.17.2-1~24O2抹灰√√√DL/T5210.1表3.0.12-2O1一般抹灰√√√DL/T5210.1表5.18.1O2保温层薄抹灰√√√DL/T5210.1表5.18.2O3门窗√√√DL/T5210.1表3.0.12-2O1木门窗安装√√√DL/T5210.1表5.20.1O2金属门窗安装√√√DL/T5210.1表5.20.2O3特种门安装√√√DL/T5210.1表5.20.4-1~3O4门窗玻璃安装√√√DL/T5210.1表5.20.6O4吊顶√√√DL/T5210.1表3.0.12-2O1板块面层吊顶√√√DL/T5210.1表5.15.21-2O5饰面板(砖)√√√DL/T5210.1表3.0.12-2O1内墙面砖粘贴√√√DL/T5210.1表5.24.1O6涂饰√√√DL/T5210.1表3.0.12-2O1水性涂料涂饰√√√DL/T5210.1表5.26.1O4建筑屋面√√√√√DL/T5210.1表3.0.12-3O1基层与保护√√√DL/T5210.1表3.0.12-2O1屋面找平层√√√DL/T5210.1表5.29.1O2保温与隔热√√√DL/T5210.1表3.0.12-2O1保温层√√√DL/T5210.1表5.29.5O3防水与密封√√√DL/T5210.1表3.0.12-2O3屋面卷材防水层√√√DL/T5210.1表5.29.9O5建筑给、排水及采暖√√√√√DL/T5210.1表3.0.12-3O1室内给水系统√√√√√DL/T5210.1表3.0.12-201室内给水管道及配件安装√√√DL/T5210.1表5.31.1O2室内排水系统√√√DL/T5210.1表3.0.12-201室内排水管道及配件安装√√√DL/T5210.1表5.31.3O3卫生器具安装√√√DL/T5210.1表3.0.12-201卫生器具安装√√√DL/T5210.1表5.31.7O2卫生器具给水配件安装√√√DL/T5210.1表5.31.8O2卫生器具排水管道安装√√√DL/T5210.1表5.31.9O6通风与空调√√√DL/T5210.1表3.0.12-3O1通风与空调设备安装√√√DL/T5210.1表3.0.12-2O1通风与空调设备安装√√√DL/T5210.1表5.32.12O2工程系统调试√√√DL/T5210.1表3.0.12-2O1工程系统调试√√√DL/T5210.1表5.32.1907建筑电气√√√√DL/T5210.1表3.0.12-301室内电气照明安装工程√√√DL/T5210.1表3.0.12-201成套配电柜、控制柜(屏、台)和动力、照明配电箱(盘)安装√√√DL/T5210.1表5.33.102电线导管、电缆导管和线槽敷设安装√√√DL/T5210.1表5.33.203电线、电缆穿管和线槽敷设√√√DL/T5210.1表5.33.304电缆头制作、接线和线路绝缘测试√√√DL/T5210.1表5.33.605普通灯具安装√√√DL/T5210.1表5.33.706专用灯具安装√√√DL/T5210.1表5.33.807开关、插座、风扇安装√√√DL/T5210.1表5.33.1008建筑物照明通电试运行√√√DL/T5210.1表5.33.1109接地装置安装√√√DL/T5210.1表5.33.1202防雷接地装置安装√√√DL/T5210.1表3.0.12-201接地装置安装√√√DL/T5210.1表5.33.1202避雷引下线安装及接闪器安装√√√DL/T5210.1表5.33.1303建筑物等电位连接及浪涌保护器安装√√√DL/T5210.1表5.33.1508智能建筑工程√√√DL/T5210.1表3.0.12-301建筑设备监控系统√√√DL/T5210.1表3.0.12-301线缆敷设√√√DL/T5210.1表5.34.102设备及软件安装√√√DL/T5210.1表5.34.603系统调试运行√√√DL/T5210.1表5.34.702火灾自动报警及消防联动系统工程√√√DL/T5210.1表3.0.12-301线缆敷设及附件安装√√√DL/T5210.1表5.34.802设备及附件安装√√√DL/T5210.1表5.34.903系统调试运行√√√DL/T5210.1表5.34.1003安全技术防范系统√√√DL/T5210.1表3.0.12-301线缆敷设√√√DL/T5210.1表5.34.102设备及软件安装√√√DL/T5210.1表5.34.1103系统调试运行√√√DL/T5210.1表5.34.1204防雷与接地√√√DL/T5210.1表3.0.12-301接地装置安装√√√DL/T5210.1表5.34.1302等电位连接及浪涌保护器安装√√√DL/T5210.1表5.34.1403接地系统测试工程√√√DL/T5210.1表5.34.1509建筑节能工程√√√DL/T5210.1表3.0.12-301围护系统节能√√√DL/T5210.1表3.0.12-201墙体节能工程√√√DL/T5210.1表5.35.102门窗节能工程 √√√DL/T5210.1表5.35.303屋面节能工程√√√DL/T5210.1表5.35.402电气动力节能√√√DL/T5210.1表3.0.12-201配电与照明节能工程√√√DL/T5210.1表5.35.90335kV配电室√√√√√DL/T5210.1表3.0.12-301地基与基础工程√√√√√DL/T5210.1表3.0.12-301定位及高程控制√√√DL/T5210.1表3.0.12-201定位及高程控制√√√DL/T5210.1表5.2.102挖方√√√DL/T5210.1表3.0.12-201土(石)方开挖√√√DL/T5210.1表5.3.1~5.3.203填方√√√DL/T5210.1表3.0.12-201土方回填√√√DL/T5210.1表5.3.304土石方堆放√√√√√DL/T5210.1表3.0.12-201土石方堆放√√√DL/T5210.1表5.3.405垫层√√√DL/T5210.1表3.0.12-201垫层√√√DL/T5210.1表5.17.2-1~5.17.2-606基础模板√√√DL/T5210.1表3.0.12-201模板安装√√√DL/T5210.1表5.12.107基础钢筋√√√DL/T5210.1表3.0.12-201钢筋加工√√√DL/T5210.1表5.12.602钢筋安装√√√DL/T5210.1表5.12.808基础混凝土√√√DL/T5210.1表3.0.12-201混凝土原材料及拌合物√√√DL/T5210.1表5.12.902混凝土施工√√√DL/T5210.1表5.12.1003混凝土结构外观尺寸偏差√√√DL/T5210.1表5.12.1104主变区域√√√√√√DL/T5210.1表3.0.12-301地基工程√√√√√DL/T5210.1表3.0.12-301定位及高程控制√√√DL/T5210.1表3.0.12-201定位及高程控制√√√DL/T5210.1表5.2.102挖方√√√DL/T5210.1表3.0.12-201土(石)方开挖√√√DL/T5210.1表5.3.1~5.3.203填方√√√DL/T5210.1表3.0.12-201土方回填√√√DL/T5210.1表5.3.302主变压器基础√√√√DL/T5210.1表3.0.12-301垫层√√√DL/T5210.1表3.0.12-201垫层√√√DL/T5210.1表5.17.202模板√√√DL/T5210.1表3.0.12-201模板安装√√√DL/T5210.1表5.12.103钢筋√√√DL/T5210.1表3.0.12-201钢筋加工√√√DL/T5210.1表5.12.602钢筋安装√√√DL/T5210.1表5.12.804混凝土√√√DL/T5210.1表3.0.12-201混凝土原材料及拌合物√√√DL/T5210.1表5.12.902混凝土施工√√√DL/T5210.1表5.12.1003混凝土外观及尺寸偏差√√√DL/T5210.1表5.12.1103厂用变压器基础√√√√DL/T5210.1表3.0.12-301垫层√√√DL/T5210.1表3.0.12-201垫层√√√DL/T5210.1表5.17.202模板√√√DL/T5210.1表3.0.12-201模板安装√√√DL/T5210.1表5.12.103钢筋√√√DL/T5210.1表3.0.12-201钢筋加工√√√DL/T5210.1表5.12.602钢筋安装√√√DL/T5210.1表5.12.804混凝土√√√DL/T5210.1表3.0.12-201混凝土原材料及拌合物√√√DL/T5210.1表5.12.902混凝土施工√√√DL/T5210.1表5.12.1003混凝土外观及尺寸偏差√√√DL/T5210.1表5.12.1104主变架构√√√√DL/T5210.1表3.0.12-301架构基础垫层√√√DL/T5210.1表3.0.12-201垫层√√√DL/T5210.1表5.17.202基础模板√√√DL/T5210.1表3.0.12-201模板安装√√√DL/T5210.1表5.12.103基础钢筋√√√DL/T5210.1表3.0.12-201钢筋加工√√√DL/T5210.1表5.12.602钢筋安装√√√DL/T5210.1表5.12.804架构基础混凝土√√√DL/T5210.1表3.0.12-201混凝土原材料及拌合物√√√DL/T5210.1表5.12.902混凝土施工√√√DL/T5210.1表5.12.1003混凝土外观及尺寸偏差√√√DL/T5210.1表5.12.1105架构安装√√√DL/T5210.1表3.0.12-201钢架构安装√√√DL/T5210.1表13.1905事故油坑、油池、排油管√√√√DL/T5210.1表3.0.12-301垫层√√√DL/T5210.1表3.0.12-201垫层√√√DL/T5210.1表5.17.202油池、油坑模板√√√DL/T5210.1表3.0.12-201模板安装√√√DL/T5210.1表5.12.103油池、油坑钢筋√√√DL/T5210.1表3.0.12-201钢筋加工√√√DL/T5210.1表5.12.602钢筋安装√√√DL/T5210.1表5.12.804油池、油坑混凝土√√√DL/T5210.1表3.0.12-201混凝土原材料及拌合物√√√DL/T5210.1表5.12.902混凝土施工√√√DL/T5210.1表5.12.1003混凝土外观及尺寸偏差√√√DL/T5210.1表5.12.1105排油管安装√√√DL/T5210.1表3.0.12-201排油管安装√√√DL/T5210.1表5.31.1605110kV屋外配电装置√√√√√√DL/T5210.1表3.0.12-301地基工程√√√√√DL/T5210.1表3.0.12-301定位及高程控制√√√DL/T5210.1表3.0.12-201定位及高程控制√√√DL/T5210.1表5.2.102挖方√√√DL/T5210.1表3.0.12-201土(石)方开挖√√√DL/T5210.1表5.3.1~5.3.203填方√√√DL/T5210.1表3.0.12-201土方回填√√√DL/T5210.1表5.3.302SVG基础√√√√DL/T5210.1表3.0.12-301垫层√√√DL/T5210.1表3.0.12-201垫层√√√DL/T5210.1表5.17.202模板√√√DL/T5210.1表3.0.12-201模板安装√√√DL/T5210.1表5.12.103钢筋√√√DL/T5210.1表3.0.12-201钢筋加工√√√DL/T5210.1表5.12.602钢筋安装√√√DL/T5210.1表5.12.804混凝土√√√DL/T5210.1表3.0.12-201混凝土原材料及拌合物√√√DL/T5210.1表5.12.902混凝土施工√√√DL/T5210.1表5.12.1003混凝土外观及尺寸偏差√√√DL/T5210.1表5.12.1103设备基础及支架√√√√DL/T5210.1表3.0.12-301基础垫层√√√DL/T5210.1表3.0.12-201垫层√√√DL/T5210.1表5.17.202基础模板√√√DL/T5210.1表3.0.12-201模板安装√√√DL/T5210.1表5.12.103基础混凝土√√√DL/T5210.1表3.0.12-201混凝土原材料及拌合物√√√DL/T5210.1表5.12.902混凝土施工√√√DL/T5210.1表5.12.1003混凝土外观及尺寸偏差√√√DL/T5210.1表5.12.1104支架安装√√√DL/T5210.1表3.0.12-201支架安装√√√DL/T5210.1表11.3.1004电缆沟√√√√DL/T5210.1表3.0.12-301砖砌沟道砌体工程√√√DL/T5210.1表3.0.12-201砖砌沟道砌体工程√√√DL/T5210.1表11.4.102砖砌沟道抹灰√√√DL/T5210.1表3.0.12-201砖砌沟道抹灰√√√DL/T5210.1表5.18.103沟道垫层√√√DL/T5210.1表3.0.12-201垫层√√√DL/T5210.1表5.17.204沟道模板√√√DL/T5210.1表3.0.12-201模板安装√√√DL/T5210.1表5.12.105沟道钢筋√√√DL/T5210.1表3.0.12-201钢筋加工√√√DL/T5210.1表5.12.602钢筋安装√√√DL/T5210.1表5.12.806沟道混凝土√√√DL/T5210.1表3.0.12-201混凝土原材料及拌合物√√√DL/T5210.1表5.12.902混凝土施工√√√DL/T5210.1表5.12.1003混凝土外观及尺寸偏差√√√DL/T5210.1表5.12.1107盖板安装√√√√DL/T5210.1表3.0.12-201盖板安装√√√√DL/T5210.1表11.4.1205110kV户外配电装置区域工程√√√√DL/T5210.1表3.0.12-301围栏安装√√√DL/T5210.1表3.0.12-201围栏安装√√√DL/T5210.1表5.13.1906综合水泵房√√√√√DL/T5210.1表3.0.12-301地基与基础工程√√√√√DL/T5210.1表3.0.12-301定位及高程控制√√√DL/T5210.1表3.0.12-201定位及高程控制√√√DL/T5210.1表5.2.102挖方√√√DL/T5210.1表3.0.12-201土(石)方开挖√√√DL/T5210.1表5.3.1~5.3.203填方√√√DL/T5210.1表3.0.12-201土方回填√√√DL/T5210.1表5.3.304土石方堆放√√√√√DL/T5210.1表3.0.12-201土石方堆放√√√DL/T5210.1表5.3.405垫层√√√DL/T5210.1表3.0.12-201垫层√√√DL/T5210.1表5.17.2-1~5.17.2-606基础模板√√√DL/T5210.1表3.0.12-201模板安装√√√DL/T5210.1表5.12.107基础钢筋√√√DL/T5210.1表3.0.12-201钢筋加工√√√DL/T5210.1表5.12.602钢筋安装√√√DL/T5210.1表5.12.808基础混凝土√√√DL/T5210.1表3.0.12-201混凝土原材料及拌合物√√√DL/T5210.1表5.12.902混凝土施工√√√DL/T5210.1表5.12.1003混凝土结构外观尺寸偏差√√√DL/T5210.1表5.12.1107站区附属工程√√√√√√DL/T5210.1表3.0.12-4~3.0.12-1001站区道路、地坪√√√√√DL/T5210.1表3.0.12-301定位及高程控制√√√DL/T5210.1表3.0.12-201定位及高程控制√√√DL/T5210.1表5.2.102挖方√√√DL/T5210.1表3.0.12-201土(石)方开挖√√√DL/T5210.15.3.1~5.3.203土石方堆放√√√DL/T5210.1表3.0.12-201土石方堆放√√√DL/T5210.1表5.3.404土方路基√√√DL/T5210.1表3.0.12-201土方路基√√√DL/T5210.1表5.37.105基层√√√DL/T5210.1表3.0.12-201级配碎石及级配碎砾石基层√√√DL/T5210.1表5.37.502水泥稳定类基层√√√DL/T5210.1表5.37.806路面√√√DL/T5210.1表3.0.12-201路面混凝土原材料及拌合物√√√DL/T5210.1表5.12.902路面混凝土施工√√√DL/T5210.1表5.12.1003水泥混凝土面层√√√DL/T5210.1表5.37.904路缘石√√√DL/T5210.1表5.37.1602站区围墙及大门√√√√DL/T5210.1表3.0.12-301定位及高程控制√√√DL/T5210.1表3.0.12-201定位及高程控制√√√DL/T5210.1表5.2.102挖方√√√DL/T5210.1表3.0.12-201土(石)方开挖√√√DL/T5210.1表5.3.1~5.3.203填方√√√DL/T5210.1表3.0.12-201土方回填√√√DL/T5210.1表5.3.304基础垫层√√√DL/T5210.1表3.0.12-201垫层√√√DL/T5210.1表5.17.2-1~5.17.2-605基础砌体√√√DL/T5210.1表3.0.12-201基础砌筑√√√DL/T5210.1表5.11.1、5.11.306主体砌体√√√DL/T5210.1表3.0.12-201主体砌筑√√√DL/T5210.1表5.11.1、5.11.307装饰装修工程√√√DL/T5210.1表3.0.12-201一般抹灰√√√DL/T5210.1表5.18.102外墙面砖粘贴√√√DL/T5210.1表5.24.208围栏及大门安装√√√√DL/T5210.1表3.0.12-201大门安装√√√DL/T5210.1表5.20.4-103站区给排水√√√DL/T5210.1表3.0.12-301室外给水管网√√√DL/T5210.1表3.0.12-201室外给水管道安装√√√DL/T5210.1表5.31.1402室外排水管网√√√DL/T5210.1表3.0.12-301室外排水管道安装√√√DL/T5210.1表5.31.1602室外排水管沟及井池√√√DL/T5210.1表5.31.1703常规水消防工程√√√DL/T5210.1表3.0.12-301室外给水管道安装√√√DL/T5210.1表5.31.1402消防水泵接合器及室外消火栓安装√√√DL/T5210.1表5.31.2504排水沟√√√DL/T5210.1表3.0.12-201砖砌沟道√√√DL/T5210.1表11.4.104站区照明√√√√DL/T5210.1表3.0.12-301成套配电柜、控制柜(屏、台)和动力、照明配电箱(盘)安装√√√DL/T5210.1表3.0.12-201成套配电柜、控制柜(屏、台)和动力、照明配电箱(盘)安装√√√DL/T5210.1表5.33.102电线、电缆导管和线槽敷设安装√√√DL/T5210.1表3.0.12-201电线、电缆导管和线槽敷设安装√√√DL/T5210.1表5.33.303电线、电缆穿管和线槽敷线√√√DL/T5210.1表3.0.12-201电线、电缆穿管和线槽敷线√√√DL/T5210.1表5.33.404电缆头制作、接线和线路绝缘测试√√√DL/T5210.1表3.0.12-201电缆头制作、接线和线路绝缘测试√√√DL/T5210.1表5.33.605建筑物景观照明灯、航空障碍标志灯和庭院灯安装√√√DL/T5210.1表3.0.12-201建筑物景观照明灯、航空障碍标志灯和庭院灯安装√√√DL/T5210.1表5.33.906照明通电试运行√√√DL/T5210.1表3.0.12-201照明通电试运行√√√DL/T5210.1表5.33.1107接地装置安装√√√DL/T5210.1表3.0.12-201接地装置安装√√√DL/T5210.1表5.33.1205水土保持工程√√√√DL/T5210.1表3.0.12-301土地整治工程√√√DL/T5210.1表3.0.12-201土地整治工程√√√DL/T5210.1表5.38.202站内绿化√√√DL/T5210.1表3.0.12-301草坪、花坛、地被栽植工程√√√DL/T5210.1表5.39.2010308附属用房√√√√√√O1地基与基础工程√√√√√√DL/T5210.1表3.0.12-3O1定位及高程控制√√√DL/T5210.1表3.0.12-2O1定位及高程控制√√√DL/T5210.1表5.2.1O2挖方√√√DL/T5210.1表3.0.12-2O1土(石)方开挖√√√DL/T5210.1表5.3.1~2O3填方√√√DL/T5210.1表3.0.12-2O1土方回填√√√DL/T5210.1表5.3.304土石方堆放√√√√√DL/T5210.1表3.0.12-201土石方堆放√√√DL/T5210.1表5.3.4O5垫层√√√DL/T5210.1表3.0.12-2O1垫层√√√DL/T5210.1表5.17.2-1~6O6基础模板√√√DL/T5210.1表3.0.12-2O1模板安装√√√DL/T5210.1表5.12.1O7基础钢筋√√√DL/T5210.1表3.0.12-2O1钢筋加工√√√DL/T5210.1表5.12.6O2钢筋安装√√√DL/T5210.1表5.12.8O8基础混凝土√√√DL/T5210.1表3.0.12-2O1混凝土原材料及拌合物√√√DL/T5210.1表5.12.9O2混凝土施工√√√DL/T5210.1表5.12.10O3混凝土结构外观及尺寸偏差√√√DL/T5210.1表5.12.1101030802主体结构√√√√√DL/T5210.1表3.0.12-3O1模板√√√DL/T5210.1表3.0.12-2O1现浇混凝土结构模板安装√√√DL/T5210.1表5.12.1O2钢筋√√√DL/T5210.1表3.0.12-2O1钢筋加工√√√DL/T5210.1表5.12.6O2钢筋安装√√√DL/T5210.1表5.12.8O3混凝土√√√DL/T5210.1表3.0.12-2O1混凝土原材料及拌合物√√√DL/T5210.1表5.12.9O2混凝土施工√√√DL/T5210.1表5.12.10O3混凝土结构外观及尺寸偏差√√√DL/T5210.1表5.12.11O4砖砌体工程√√√DL/T5210.1表3.0.12-2O1填充墙砌体√√√DL/T5210.1表5.11.5O3建筑装饰装修√√√√√DL/T5210.1表3.0.12-301楼面与地面√√√DL/T5210.1表3.0.12-2O1基土质量√√√DL/T5210.1表5.17.1O2垫层√√√DL/T5210.1表5.17.2-2~6O3中间层处理√√√DL/T5210.1表5.17.3-1~4O4面层√√√DL/T5210.1表5.17.2-1~24O2抹灰√√√DL/T5210.1表3.0.12-2O1一般抹灰√√√DL/T5210.1表5.18.1O2保温层薄抹灰√√√DL/T5210.1表5.18.2O3门窗√√√DL/T5210.1表3.0.12-2O1金属门窗安装√√√DL/T5210.1表5.20.2O2门窗玻璃安装√√√DL/T5210.1表5.20.6O4建筑屋面√√√√√DL/T5210.1表3.0.12-3O1基层与保护√√√DL/T5210.1表3.0.12-2O1屋面找平层√√√DL/T5210.1表5.29.1O2保温与隔热√√√DL/T5210.1表3.0.12-2O1保温层√√√DL/T5210.1表5.29.5O3防水与密封√√√DL/T5210.1表3.0.12-2O3屋面卷材防水层√√√DL/T5210.1表5.29.905建筑电气√√√√DL/T5210.1表3.0.12-301室内电气照明安装工程√√√DL/T5210.1表3.0.12-201成套配电柜、控制柜(屏、台)和动力、照明配电箱(盘)安装√√√DL/T5210.1表5.33.102电线导管、电缆导管和线槽敷设安装√√√DL/T5210.1表5.33.203电线、电缆穿管和线槽敷设√√√DL/T5210.1表5.33.304电缆头制作、接线和线路绝缘测试√√√DL/T5210.1表5.33.605普通灯具安装√√√DL/T5210.1表5.33.706专用灯具安装√√√DL/T5210.1表5.33.807开关、插座、风扇安装√√√DL/T5210.1表5.33.1008建筑物照明通电试运行√√√DL/T5210.1表5.33.1109接地装置安装√√√DL/T5210.1表5.33.1202防雷接地装置安装√√√DL/T5210.1表3.0.12-201接地装置安装√√√DL/T5210.1表5.33.1202避雷引下线安装及接闪器安装√√√DL/T5210.1表5.33.1306建筑节能工程√√√DL/T5210.1表3.0.12-301围护系统节能√√√DL/T5210.1表3.0.12-201墙体节能工程√√√DL/T5210.1表5.35.102门窗节能工程 √√√DL/T5210.1表5.35.303屋面节能工程√√√DL/T5210.1表5.35.402电气动力节能√√√DL/T5210.1表3.0.12-201配电与照明节能工程√√√DL/T5210.1表5.35.909储能区域01地基与基础工程√√√√√DL/T5210.1表3.0.12-301定位及高程控制√√√DL/T5210.1表3.0.12-201定位及高程控制√√√DL/T5210.1表5.2.102挖方√√√DL/T5210.1表3.0.12-201土(石)方开挖√√√DL/T5210.1表5.3.1~5.3.203填方√√√DL/T5210.1表3.0.12-201土方回填√√√DL/T5210.1表5.3.304土石方堆放√√√√√DL/T5210.1表3.0.12-201土石方堆放√√√DL/T5210.1表5.3.405垫层√√√DL/T5210.1表3.0.12-201垫层√√√DL/T5210.1表5.17.2-1~5.17.2-606基础模板√√√DL/T5210.1表3.0.12-201模板安装√√√DL/T5210.1表5.12.107基础钢筋√√√DL/T5210.1表3.0.12-201钢筋加工√√√DL/T5210.1表5.12.602钢筋安装√√√DL/T5210.1表5.12.808基础混凝土√√√DL/T5210.1表3.0.12-201混凝土原材料及拌合物√√√DL/T5210.1表5.12.902混凝土施工√√√DL/T5210.1表5.12.1003混凝土结构外观尺寸偏差√√√DL/T5210.1表5.12.112安装工程√√√√DL/T5161.1表5.0.31光伏区安装工程√√√√DL/T5161.1表5.0.31#1方阵光伏发电单元安装√√√√DL/T5161.1表5.0.21光伏支架安装√√√√DL/T5161.1表5.0.21光伏支架安装√√√GB50794表5.2.22电池组件安装√√√√DL/T5161.1表5.0.21电池组件安装√√√GB50794表5.3.23逆变器安装√√√√DL/T5161.1表5.0.21逆变器安装√√√GB50794表5.5.12逆变器带电试运行√√√√DL/T5161.13表3.0.34箱式变压器安装√√√√DL/T5161.1表5.0.21安装检查√√√√DL/T5161.3表1.0.2、表1.0.6、表1.0.7、表1.0.102带电试运√√√√DL/T5161.3表3.0.75电缆敷设工程√√√√DL/T5161.1表5.0.21电缆管配制与敷设√√√DL/T5161.5表1.0.22电缆敷设√√√DL/T5161.5表2.0.3DL/T5161.5表2.0.43电力电缆终端制作及安装√√√DL/T5161.5表3.0.24电力电缆接头制作及安装√√√DL/T5161.5表3.0.35电缆防火及阻燃√√√DL/T5161.5表4.0.26防雷及接地装置安装√√√√DL/T5161.1表5.0.21接地装置安装√√√DL/T5161.6表1.0.22#2方阵光伏发电单元安装√√√√DL/T5161.1表5.0.21光伏支架安装√√√√DL/T5161.1表5.0.21光伏支架安装√√√GB50794表5.2.22电池组件安装√√√√DL/T5161.1表5.0.21电池组件安装√√√GB50794表5.3.23逆变器安装√√√√DL/T5161.1表5.0.21逆变器安装√√√DL/T5161.13表2.0.22逆变器带电试运行√√√√DL/T5161.13表3.0.34箱式变压器安装√√√√DL/T5161.1表5.0.21安装检查√√√√DL/T5161.3表1.0.2、表1.0.6、表1.0.7、表1.0.102带电试运√√√√DL/T5161.3表3.0.75电缆敷设工程√√√√DL/T5161.1表5.0.21电缆管配制与敷设√√√DL/T5161.5表1.0.22电缆敷设√√√DL/T5161.5表2.0.3DL/T5161.5表2.0.43电力电缆终端制作及安装√√√DL/T5161.5表3.0.24电力电缆接头制作及安装√√√DL/T5161.5表3.0.35电缆防火及阻燃√√√DL/T5161.5表4.0.26防雷及接地装置安装√√√√DL/T5161.1表5.0.21接地装置安装√√√DL/T5161.6表1.0.23#3方阵光伏发电单元安装√√√√DL/T5161.1表5.0.21光伏支架安装√√√√DL/T5161.1表5.0.21光伏支架安装√√√GB50794表5.2.22电池组件安装√√√√DL/T5161.1表5.0.21电池组件安装√√√GB50794表5.3.23逆变器安装√√√√DL/T5161.1表5.0.21逆变器安装√√√DL/T5161.13表2.0.22逆变器带电试运行√√√√DL/T5161.13表3.0.34箱式变压器安装√√√√DL/T5161.1表5.0.21安装检查√√√√DL/T5161.3表1.0.2、表1.0.6、表1.0.7、表1.0.102带电试运√√√√DL/T5161.3表3.0.75电缆敷设工程√√√√DL/T5161.1表5.0.21电缆管配制与敷设√√√DL/T5161.5表1.0.22电缆敷设√√√DL/T5161.5表2.0.3DL/T5161.5表2.0.43电力电缆终端制作及安装√√√DL/T5161.5表3.0.24电力电缆接头制作及安装√√√DL/T5161.5表3.0.35电缆防火及阻燃√√√DL/T5161.5表4.0.26防雷及接地装置安装√√√√DL/T5161.1表5.0.21接地装置安装√√√DL/T5161.6表1.0.24#4方阵光伏发电单元安装√√√√DL/T5161.1表5.0.21光伏支架安装√√√√DL/T5161.1表5.0.21光伏支架安装√√√GB50794表5.2.22电池组件安装√√√√DL/T5161.1表5.0.21电池组件安装√√√GB50794表5.3.23逆变器安装√√√√DL/T5161.1表5.0.21逆变器安装√√√DL/T5161.13表2.0.22逆变器带电试运行√√√√DL/T5161.13表3.0.34箱式变压器安装√√√√DL/T5161.1表5.0.21安装检查√√√√DL/T5161.3表1.0.2、表1.0.6、表1.0.7、表1.0.102带电试运√√√√DL/T5161.3表3.0.75电缆敷设工程√√√√DL/T5161.1表5.0.21电缆管配制与敷设√√√DL/T5161.5表1.0.22电缆敷设√√√DL/T5161.5表2.0.3DL/T5161.5表2.0.43电力电缆终端制作及安装√√√DL/T5161.5表3.0.24电力电缆接头制作及安装√√√DL/T5161.5表3.0.35电缆防火及阻燃√√√DL/T5161.5表4.0.26防雷及接地装置安装√√√√DL/T5161.1表5.0.21接地装置安装√√√DL/T5161.6表1.0.25#5方阵光伏发电单元安装√√√√DL/T5161.1表5.0.21光伏支架安装√√√√DL/T5161.1表5.0.21光伏支架安装√√√GB50794表5.2.22电池组件安装√√√√DL/T5161.1表5.0.21电池组件安装√√√GB50794表5.3.23逆变器安装√√√√DL/T5161.1表5.0.21逆变器安装√√√DL/T5161.13表2.0.22逆变器带电试运行√√√√DL/T5161.13表3.0.34箱式变压器安装√√√√DL/T5161.1表5.0.21安装检查√√√√DL/T5161.3表1.0.2、表1.0.6、表1.0.7、表1.0.102带电试运√√√√DL/T5161.3表3.0.75电缆敷设工程√√√√DL/T5161.1表5.0.21电缆管配制与敷设√√√DL/T5161.5表1.0.22电缆敷设√√√DL/T5161.5表2.0.3DL/T5161.5表2.0.43电力电缆终端制作及安装√√√DL/T5161.5表3.0.24电力电缆接头制作及安装√√√DL/T5161.5表3.0.35电缆防火及阻燃√√√DL/T5161.5表4.0.26防雷及接地装置安装√√√√DL/T5161.1表5.0.21接地装置安装√√√DL/T5161.6表1.0.20202升压站设备安装调试√√√√DL/T5161.1表5.0.301主变压器系统设备安装√√√√DL/T5161.1表5.0.201主变压器安装√√√√DL/T5161.1表5.0.201主变压器本体安装√√√DL/T5161.3表1.0.602主变压器器身检查√√√√DL/T5161.3表1.0.703主变压器附件安装√√√DL/T5161.3表1.0.804主变压器注油、热油循环及密封试验√√√DL/T5161.3表1.0.905主变压器整体检查√√√DL/T5161.3表1.0.1002主变压器系统附属设备安装√√√√DL/T5161.1表5.0.201中性点隔离开关安装√√√DL/T5161.2表5.0.202中性点避雷器安装√√√DL/T5161.2表6.0.203中性点电流互感器安装√√√DL/T5161.3表2.0.204控制柜及端子箱检查安装√√√DL/T5161.8表3.0.205软母线安装√√√DL/T5161.4表7.0.206矩形母线安装√√√DL/T5161.4表3.0.203主变压器带电试运√√√√DL/T5161.3表3.0.702主控及直流设备安装√√√√DL/T5161.1表5.0.301主控室设备安装√√√√DL/T5161.1表5.0.201控制及保护和自动化屏安装√√√DL/T5161.8表4.0.202直流屏及不间断电源设备安装√√√DL/T5161.13表2.0.203二次回路检查及接线√√√DL/T5161.8表5.0.202蓄电池组安装√√√√DL/T5161.1表5.0.201蓄电池安装√√√DL/T5161.9表1.0.2DL/T5161.9表2.0.202充放电及容量测定√√√DL/T5161.9表3.0.20335kV配电装置安装√√√√DL/T5161.1表5.0.301主母线及旁路母线安装√√√√DL/T5161.1表5.0.201矩形母线安装√√√DL/T5161.4表3.0.202接地开关安装√√√DL/T5161.2表5.0.202电压互感器及避雷器安装√√√√DL/T5161.1表5.0.201避雷器安装√√√DL/T5161.2表6.0.202电压互感器安装√√√DL/T5161.3表2.0.303箱柜安装√√√DL/T5161.81.0.210.135kV配电装置带电试运√√√√DL/T5161.1表6.0.404110kV气体绝缘金属封闭开关设备安装√√√√DL/T5161.1表5.0.301气体绝缘金属封闭开关设备安装√√√√DL/T5161.1表5.0.201基础检查及设备支架安装√√√DL/T5161.2表1.0.202气体绝缘金属封闭开关设备本体安装√√√DL/T5161.2表1.0.302配套设备安装√√√√DL/T5161.1表5.0.201软母线安装√√√DL/T5161.4表7.0.203就地控制设备安装√√√√DL/T5161.1表5.0.201控制柜及就地箱安装√√√DL/T5161.8表3.0.202二次回路检查及接线√√√DL/T5161.8表5.0.204110kV气体绝缘金属封闭开关设备带电试运√√√√DL/T5161.2表9.0.60535kV及站用配电装置安装√√√√DL/T5161.1表5.0.301变压器安装√√√√DL/T5161.1表5.0.201变压器本体安装√√√DL/T5161.3表1.0.602变压器器身检查√√√DL/T5161.3表1.0.703变压器附件安装√√√DL/T5161.3表1.0.804变压器整体检查√√√DL/T5161.3表1.0.1002400V站用低压配电装置安装√√√√DL/T5161.1表5.0.201低压变压器安装√√√DL/T5161.3表1.0.203二次回路检查接线√√√DL/T5161.8表5.0.20335kV系统设备带电试运√√√√DL/T5161.1表6.0.504400V系统设备带电试运√√√√、DL/T5161.1表6.0.606无功补偿装置安装√√√√DL/T5161.1表5.0.301电抗器安装√√√√DL/T5161.1表5.0.201隔离开关安装√√√DL/T5161.2表5.0.202电抗器安装√√√DL/T5161.2表4.0.203母线安装√√√DL/T5161.4表7.0.210无功补偿装置带电试运√√√√DL/T5161.2表9.0.707全站电缆施工√√√√DL/T5161.1表5.0.301电缆管配制及敷设√√√√DL/T5161.1表5.0.201电缆管配制及敷设√√√DL/T5161.5表1.0.202电缆支架(桥架)配制及安装√√√√DL/T5161.1表5.0.201电缆支架(桥架)安装√√√DL/T5161.5表1.0.303电缆敷设√√√√DL/T5161.1表5.0.201屋内电缆敷设√√√DL/T5161.5表2.0.202屋外电缆敷设√√√DL/T5161.5表2.0.304电力电缆终端及中间接头制作√√√√DL/T5161.1表5.0.201电力电缆终端制作及安装√√√DL/T5161.5表3.0.205控制电缆终端制作及安装√√√√DL/T5161.1表5.0.201控制电缆终端制作及安装√√√DL/T5161.5表3.0.406电缆防火与阻燃√√√√DL/T5161.1表5.0.201电缆防火与阻燃√√√DL/T5161.5表4.0.208全站防雷及接地装置安装√√√√DL/T5161.1表5.0.301避雷针及引下线安装√√√√DL/T5161.1表5.0.201避雷针及引下线安装√√√DL/T5161.6表3.0.202接地装置安装√√√√DL/T5161.1表5.0.201屋外接地装置安装√√√DL/T5161.6表1.0.202屋内接地装置安装√√√DL/T5161.6表2.0.203电气二次系统等电位接地装置安装√√√DL/T5161.6表4.0.209通信工程安装√√√√DL/T5161.1表5.0.301光纤通信设备安装√√√√DL/T5161.1表5.0.201机架安装√√√DL/T5161.11表6.0.202通信设备安装√√√DL/T5161.11表4.0.203站内通信光缆安装√√√DL/T5161.11表7.0.202通信系统防雷接地安装√√√√DL/T5161.1表5.0.201通信站(系统)防雷接地安装√√√DL/T5161.11表8.0.210储能设备安装01储能蓄电池仓安装√√√√DL/T5161.1表5.0.201箱柜安装√√√DL/T5161.81.0.202二次回路检查及接线√√√DL/T5161.8表5.0.202变压器安装√√√√DL/T5161.1表5.0.201变压器本体安装√√√DL/T5161.3表1.0.602变压器器身检查√√√DL/T5161.3表1.0.703变压器附件安装√√√DL/T5161.3表1.0.804变压器整体检查√√√DL/T5161.3表1.0.1003400V站用低压配电装置安装√√√√DL/T5161.1表5.0.201低压变压器安装√√√DL/T5161.3表1.0.203二次回路检查接线√√√DL/T5161.8表5.0.20435kV系统设备带电试运√√√√DL/T5161.1表6.0.505400V系统设备带电试运√√√√DL/T5161.1表6.0.603场内电力线路工程√√√√GB50173-2014表D.0.25011路35kV场内电力线路工程√√√√GB50173-2014表D.0.2401土石方工程√√√√GB50173-2014表D.0.2401路径复测√√√GB50173-2014表D.0.102普通(掏挖)和拉线基础分坑√√√GB50173-2014表D.0.202基础工程√√√√GB50173-2014表D.0.2401钢管塔、铁塔基础(浇筑前)√√√GB50173-2014表D.0.5、表D.0.2002钢管塔、铁塔基础(浇筑后)√√√GB50173-2014表D.0.6、表D.0.2003杆塔工程√√√√GB50173-2014表D.0.2401自立式铁塔组立√√√GB50173-2014表D.0.8、表D.0.2104架线工程√√√√GB50173-2014表D.0.2401导地线(含光缆)展放√√√GB50173-2014表D.0.11、表D.0.2302导地线接续管√√√GB50173-2014表D.0.12、表D.0.2303导地线(含光缆)紧线√√√GB50173-2014表D.0.13、表D.0.2304附件安装(含光缆)√√√GB50173-2014表D.0.14、表D.0.2205接地工程√√√√GB50173-2014表D.0.2401接地装置施工√√√GB50173-2014表D.0.1706线路防护工程√√√√GB50173-2014表D.0.2401线路防护设施√√√GB50173-2014表D.0.1907电气工程√√√√GB50173-2014表D.0.2401光缆测试√√√GB50173-2014表D.0.1502对地、风偏与交叉跨越√√√GB50173-2014表D.0.1603杆上电气设备√√√GB50173-2014表D.0.1808电力电缆线路工程√√√√DL/T5161.1表5.0.301电缆管配制及敷设√√√DL/T5161.5表1.0.202电缆支架(桥架)安装√√√DL/T5161.5表1.0.303电缆敷设√√√DL/T5161.5表2.0.3DL/T5161.5表2.0.404电力电缆终端制作及安装√√√DL/T5161.5表3.0.205电力电缆接头制作及安装√√√DL/T5161.5表3.0.306电缆防火与阻燃√√√DL/T5161.5表4.0.207光缆安装√√√DL/T5161.11表7.0.208光缆测试√√√GB50173表D.0.15022路35kV场内电力线路工程√√√√GB50173-2014表D.0.24~NN回路35kV场内电力线路工程√√√√GB50173-2014表D.0.24注:2回路35kV场内电力线路工程~N回路35kV场内电力线路工程质量验收范围划分内容按照集电线路1回路35kV场内电力线路工程进行(共N个回路)。04110kV~750kV送出线路工程√√√√√DL/T5168表C.0.20100土石方工程√√√√√√DL/T51686表C.0.101路径复测√√√DL/T5168表4.2.2、表A.0.102普通基础分坑及开挖√√√DL/T51684.2.3A.0.203拉线基础分坑及开挖√√√DL/T51684.2.4A.0.204岩石、掏挖基础分坑及开挖√√√DL/T51684.2.5A.0.305施工基面及电气开方√√√DL/T51684.2.6A.0.40200基础工程√√√√√DL/T5168表C.0.101现浇铁塔基础施工√√√DL/T
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2024年足球裁判员考试重难点试题及答案
- 游泳救生员资格考试常见问题解析的试题及答案
- 2024游泳救生员独特视角试题及答案
- 2024年农业植保员考试沟通能力需求与试题
- 2024年篮球裁判员的持续学习试题及答案
- 风电开发工程可行性研究报告
- 农作物繁育项目管理试题及答案
- 优化2024年篮球裁判员考试复习的具体步骤 试题及答案
- 2024年游泳救生员新兴技能试题及答案
- 比赛中裁判员的角色与任务试题及答案
- 2024-2025年江苏专转本英语历年真题(含答案)
- 山东科技大学离散数学复习题
- 高压氧护理进修汇报
- 第二单元 第八课 巧用蓝牙做工具 说课稿2024-2025学年人教版(2024)初中信息科技八年级上册
- 《新时代提升基层治理能力的根本路径》课件
- 产品审核程序(含表格)
- 2024届清华大学强基计划数学学科笔试试题(附答案)
- 5、科技成果转化的组织实施与激励奖励制度
- 全国统一规范电子税务局概况介绍及操作辅导
- 工商企业管理毕业论文范文(4篇)
- 浙江省杭州市(2024年-2025年小学三年级语文)人教版开学考试(上学期)试卷(含答案)
评论
0/150
提交评论