1.Consideralargemodern(15000-kpa)steamgeneratorfiringpulverizedcoal.Explainin

detailhowthehotgasesgiveuptheirheatinpassingfromthefireballinthefurnacetothe

stackexit.Indicateinyourexplanation,thevariouspartsoftheunitcontactedbythegases

intheircorrectsequence.(15marks)

ANSWER:

2.List5characteristicsoffueloilthatmustbeconsideredwhenselectingapowerplantfuel.

Explainhowtheseimpactontheoperationoftheplant.(15marks)

ANSWER

A.THESPECIFICGRAVITY

-enablestheengineertodetermineiftheoilislightorheavy

-generallythehigherthespecificgravity,thelowerthehydrogencontentandtheharderit

istoignitethefuel

-lightfueloilavoidsthecostofkeepinganoiltankwarmed

-heavyfueloilsarethecheapesttopurchasebutitbecomescriticaltoknowthewater

contentoftheheavyfueloil.Someheavyfueloilsrequiretobeheatedtoashighas135

degreesCattheburnersupplybeforetheywillbumcompletely

B.THEHEATINGVALUE

-isrequiredtobeknown

-enablestheengineertocalculateboilerefficiencywhentheboilerisrunningsteadywith

aminimumofinterference

-boilerefficiencyistheheatsuppliedtothesteamperhourdividedbytheheatavailable

fromthefuelperhour

C.THEFLASHPOINT

-enablesengineertojudgeiffuelissafetostorenearabuilding

-thehighertheflashpoint,thesafertheproductwilltendtobetohandleandstore

-normallyfueloilswithaflashpointoflessthan66degreesCwouldnotbestored

-allfueloilsnormallyhaveaflashpointofaround90-95degreesC

-fueloilsaresafertohandlethankeroseneorgasolinewhichhaveamuchlowerflash

point

Flashpoint:thetemperaturewhereaproductgivesoffenoughvaportobeignitedbutnotsustain

aflame

D.CONGEALINGORPOURPOINT

-enablestheengineertoknowatwhattemperaturetheoilwillrefusetoflow

-tracersteamlineswouldneedtobeinstalledonallfuellinesinareasthatexperience

sub-zerotemperatures

-toknowthepourpointwouldindicatewhenthetracersteamlinesshouldbebrought

backintoserviceinthefall

E.VISCOSITY

-isameasureoftheresistancetoflow

-itisexpressedintimeinsecondsthattheoilatacertaintemperaturewilltaketoflow

throughastandardsizedholebygravity

-thehighertheviscositythemoretroubleonecanexpectwhenburningthefuel

-iftheviscosityistoohigh,atomizationispoorandexcessivecarbondepositswillresult

onthefurnacefloorandintheboilerheatingareas

theflamepatternwillbepoorwithincompletecombustionandalowerheatrelease.Operatingcostsasa

resultwillbehigher

3.Asashiftengineerinchargeofalargehighpressure(15000kpa)multiburnergasfired

boilerequippedwithasuperheater,economizer,forceddraftfans,andautomatic

combustioncontrols.Describethepossiblecausesofandtheactionsthatyouwouldtakein

thefollowingcircumstances.Theboilerisonsteadyload.

a.Alowdrumwaterlevelcondition.(8marks)

ANSWER

A.BOILERFEEDWATERLEVELCONTROLVALVE

-cause:isolationvalveclosedoninletoroutlet

-remedy:openvalve

-cause:failed

-remedy:openby-passaroundcontroller

B.BOILERFEEDWATERPUMP

-cause:failed

-remedy:startbackuppump

-cause:isolationvalveclosed

-remedy:openvalve

-cause:cavitation

-remedy:drainandbleedpumptoriditoftheairlock;thenrestartpump

C.INSTRUMENTATION/EQUIPMENTFAILURE

-cause:failureofswitch

-remedy:replaceswitch

-cause:electricalwire

-remedy:checkforlooseconnectionsandtighten

-remedy:ifshortcircuitingduetobarewiresorbrittleinsulation:replace

wire

-cause:mercuryswitchglassiscracked

-remedy:replacemercuryswitch

-cause:sedimentinfloatchamber

-remedy:blowoutthechamberbymeansofdrainvalveprovided

-cause:lowwaterfuelcutoffswitch

-remedy:testregularlytoensureitisworkingproperly.

Immediatelyreplaceifnotworking.Thisisacritical

pieceofequipmentinstrumentation.

b.Aflamefailure.(7marks)”

ANSWER

-cause:fuelsupplypressuredrops

-remedy:shutdownmainburners.Allalarmsmustberesetandall

parametersmetbeforereignitingburners.

-cause:lowwaterfuelcutoffhasactuated

-remedy:findcauseoflowwaterlevelandaddressthatissuebefore

attemptingtore-establishflame

-cause:ifboilerisnormallyrunatslightlynegativepressureanditgoestopositive

pressure一boilerwillshutdown

-remedy:louversoninducedfanshaveopenedtoorapidlycausing

suddenpressurechangefromnegativetopositive.

Operator:resetalarm,thenclosethelouversslightlytore­

establishnegativepressurewithinthefurnace.

-cause:burnermalfunction

-remedy:isolatethatburnerandreplaceitwhentheunitisshutdownfor

maintainancetoallowcontinuedoperation

-cause:tubefailure

-remedy:catastrophictubefailure:waterhasextinguishedflamesatthe

burners.Operator:shutdownentireunitimmediately.Ensure

inducedfansarerunningtopurgethefurnaceofcombustiblegases

orpocketsofgases.Watertubeswillneedtobereplacedandunit

willneedtobeinspectedbyaqualifiedboilerinspectorbeforeunit

isbroughtbackintoservice.

-cause:fireeyesnotfunctioningproperly

-remedy:cleanfireeyesaccordingtoprocedure

4.Awatertubeboilerhasjustbeentakenofflineandisintheprocessofcoolingdown.

Describetheproperprocedureforpreparingtheboilerforinspectionandthesafety

precautionstobetakenduringtheinspection.(10marks)

ANSWER4

1.Reduceloadonboiler.

2.Atabout50%load,operatethesootblowerstocleanthefiresidesurfacesasmuchaspossible.

3.Whenthefiresareout,allowtheboilertocooltoapressureof35-70Kpaandthenopenthe

drumvents.

4.Isolatetheboilerbyclosingthesteamstopvalves;feedwaterstopvalves;fuelvalves;air

dampersonFDfans;steamtosootblowervalves;chemicalfeedvalves;steamtofanorfeed

pumpturbines;atomizingsteamvalves;continuousblowdownvalvesandbyopeningcircuit

breakersoffeedpumpmotors,fanmotors,chemicalfeedpumpmotors,retractablesootblower

motors,rotaryairheaterdrivesoranyvalveorcircuitbreakerwhichmayallowanygas,liquid

orsolidtoentertheboilerorcouldcausemotionofequipmentwithintheboiler.Tagallvalves

withbrightlycolored"DONOTOPERATE,,tagsandrecordallthesesotheycanbeaccounted

forwhentheyareremovedinpreparationforstartinguptheboileragain.Thesetagsarenotto

removedortamperedwithuntilallworkissignedoffandaretoberemovedonlybytheoperator.

5.Whenboilerwaterhascooledtoabout90degreesC,opentheblowdownvalvesanddrainboiler.

6.Ifitwasformaintenance,theboilerwouldnowbeflushedoutwithahighpressurewaterhose.

Theinspectorwillwanttoinspectsludge;scale;buildup;etcsoavoidthisstepuntilapprovalby

theinspectorisreceived.

7.Whentheboilerhasdrained,closeandtagtheblowdownvalve.

8.Openfiresideaccessdoor.

9.Ifextensionlightsaretobeused,atransformermustbeprovidedwhichchangespowerto12Vto

eliminatethedangerofelectrocutiontopersonnelintheboiler.

10.Provideprotectiveclothing,goggles,faceshieldandgloveswherenecessary.

SAFETYPRECAUTIONS:

1.Properpersonalprotectiveequipment:coveralls,glasses/goggles,gloves,steeltoedworkboots,

faceshield,radio,flashlight,personalairmonitor.

2.Trainedpersonnelaretheonlypersonsallowedtoentervessel:CONFINEDSPACE.

3.Preplanningmeetingtoplanallaspectsoftheconfinedspaceentry:allinvolveddepartmentsor

personnelshouldbeinattendanceatallrelatedmeetings.Thisincludestheemergencypersonnel

aswell.

4.Safeworkplansorproceduresmustbeauthorizedpriortoanyentryorworkbeingdone.

5.Meetingjustpriortoentrytogooverallaspectsofentry.

6.Allpermitsareinorderandapproved.

7.Ongoingairqualitytesting.Dependingonvesselmaybeeverysixhoursorcontinual.If

continualallpersonnelenteringvesselmustwearSCBAgear.Itisrecommendedthatall

personnelwearsomekindofpersonalairmonitorsuchasthe“RATTLER“tomonitorany

changesinairquality.

8.SCBAequipmentifnecessary.

9.Qualifiedstand-bypersonattheentryofthevessel.Thispersoncanatnotimeleavethevessel

unattended-mustberelievedbyanotherqualifiedpersonbeforeleavingtheareaforanyreason.

10.Recordofallpersonnelwhoenterthevessel.Sign-insheetaswellasidentificationtagslefton

boardatentrytovessel.

11.Confinedspaceentrytagshungatentrytovessel.

12.Radiocontactbetweenpersonnelenteringvessel,stand-bypersonandemergencypersonnelat

alltimes.

13.Updatingpennitsandairsamplingasnecessary.

14.Iftheentryisleftopenatanytimewithnopersonnelaround,a"DONOTENTER“signshould

behungdirectlyovertheopeningoftheentry.

IfdangerousgassuchasH2Sispresentintheareaorhasthepotentialofbeinginthearea:signsshould

behungindicatingthesame.

5.a.Whatisthepurposeofawatercolumnonaboiler.(3marks)

ANSWER

Actsasareservoirtodampenagitationofthewater.

-makesthelevelinthegageglasseasiertoread

Trapanysludgeorsedimentandpreventitfromcollectingintheglassconnections

Providesaplacefortheinstallationofalarmfloats

Providesvisibleindicationofwaterlevelinboiler.

Allowsoperatortocheckorverifywaterlevelinboilershouldthegageglassbebroken.

-usingtri-cocksattachedtowatercolumn.

b.Describethebestprocedureforverifyingtheproperoperationofawatercolumnandgauge

glassonanoperatingboiler.(6marks)

ANSWER

1.Closethegagesteamvalveandthegagewatervalveinordertoisolatethegagebeforechecking

thecolumnconnections

2.Closecolumnwatervalveandopencolumndrainvalvethusblowingthroughthesteam

connectionandthecolumnandprovingthemclear

3.Closecolumnsteamvalveandopencolumnwatervalvethusblowingthroughthewater

connectionandprovingitclear

4.Closecolumndrainvalveandopencolumnsteamvalveputtingcolumnbackinoperating

condition

5.Opengagedrainvalveandgagesteamvalvethusblowingthroughthesteamconnectionandthe

gageglassandprovingthemclear

6.Closegagesteamvalveandopengagewatervalvethusblowingthroughthewaterconnection

andprovingitclear

7.Opengagesteamvalveandclosegagedrainvalveputtinggagebackinoperatingcondition

NOTE:allconnectionstobothcolumnandgagehavenowbeenblownthroughseparatelytoprove

themclear.

c.Describethecorrectprocedureforreplacingabrokentubulargaugeglassonanoperating

boiler.(6marks)

ANSWER

1.Shutoffthesteamandwatervalvesonthegage

2.Openthegagedrainvalve

3.Removebrokengageglass.Eachendoftheglassisheldinplaceinthegagefittingbymeansof

anutandawasher.Byunscrewingthenuts,thewashersandglassmayberemoved

4.Opengagevalvestoblowoutsmallfragmentsofglassandthencloseagain

5.Cutnewglasstocorrectlengthusingaglasstubecutter

6.Placenutsandnewwashersontheglassandinstallinthegagefittings.Somepowderedgraphite

maybeusedasalubricantbetweenwashersandnuts.Nutsshouldbehandtightenedonly

7.Heatuptheglassslowlybycrackingopengagesteamvalve.Thenclosegagedrainvalveand

crackopengagewatervalve.Whenwaterlevelinglassstabilizes,openthegagesteamandwater

valvesfully

NOTE:operatorsshouldwearproperPPEtoprotecteyes,face,handsetcincasenewglassburstswhen

putintoservice.Useextremecautionwhenpressurizingthegageglass

6.Describetheprincipleofoperationandthemethodoftestingofeachofthefollowingsafety

devicesfoundonapackagedboiler.

a.Highlimitpressurecontrol.(5marks)

ANSWER

HighLimitControl(HighSteamPressureFuelCut-Off)

TheBoilerCoderequiresthatautomaticallyfiredsteamheatingboilersnotunderconstantsupervision

mustbeequippedwithahighlimitpressurecontrolthatshutsoffthefuelsupplyataboilerpressurenot

toexceed103kPa(15psi).

Thiscontrolmustbeconnectedtotheboilerwithoutanyshut-offvalvesanditshallbeprotectedbya

syphonorasimilarmeansofmaintainingawatersealtopreventsteamfromenteringthecontrol.

Thepurposeofthehighlimitcontrolistoshutoffthefiringequipmentshouldtheoperatinglimit

pressurecontrolfailtoshutofftheburnerwhenitreachesitscut-outpointandpressurecontinuestorise.

Thehighlimitcontrolthusactsasasafeguardtopreventexcessiveboilerpressureandwillpreventthe

pressurefromrisingtothepointatwhichthesafetyvalveswouldopenupandreleasethesteamto

atmosphere.

Indesignandoperationthehighlimitcontrolisquitesimilartotheon-offpressurecontrolbutitisnot

equippedwithadifferentialspringsothatthecut-outandcut-inpointsofthecontrolareveryclose

together.Also,thecontrolafterhavingshutofftheburneronreachingitscut-outpoint,locksoutand

doesnotautomaticallystarttheburnerupagainwhenthepressuredrops.Instead,ithastobemanually

resetbyaresetleverorbuttonontheoutsideofthecontrolbeforetheboilercanbestartedagain.The

reasonforthisarrangementistoindicatetotheboileroperatorthattheoperatingcontrolis

malfunctioning.Theoperatingcontrolmustberepairedorreplacedimmediately.

Itisgenerallyrecommendedtosetthecut-outpressureofthehighlimitcontrolsufficientlyabovethe

cut-outpressureoftheoperatinglimitcontroltoavoidunnecessarylock-outsshouldtheoperating

controlbeslightlyoutofcalibration.Ideallythecut-outpressureofthehighlimitcontrolshouldnot

exceedninetypercentofthesafetyvalvesetting.

4thcllOPressureControl

TEST

Thepressureandtemperaturehighlimitcontrolscannotbetested

duringnormalboileroperationsincetheyonlyoperateabovethe

cut-outpointoftheoperatingcontrol.Totestthehighlimitcontrol,

disconnectthepowertotheboilercontrolsandplaceatestlead

acrosstheterminalsoftheoperatingcontrol.Checkthesettingofthe

highlimitcontrol.Restorepowertothecontrolsandstarttheboiler.

Allowtheboilertofireuntilthesteampressureorwatertemperature

reachesthesettingofthehighlimitcontrol.Thecontrolshould

operateatthispointandshutdownthefiringequipment.Ifthetestis

O.K.,disconnectthepowerandremovethetestlead.Resetthehigh

limitcontrolandputtheboilerbackintooperation.

Thehighlimitcontrolofalow-pressuresteamheatingboilershouldopenatapressurehigherthanthe

cut-outpressureoftheoperatingcontrol,butlowerthan103kPa(15psi),thepoppingpressureofthe

safetyvalve.Onlow-pressurehotwaterboilersthecut-outtemperatureofthehighlimitcontrolshould

besetabovethecut-outsettingoftheoperatingcontrolbutneverhigherthat121℃(250°F),the

maximumallowablewatertemperaturefortheboiler.

Generally,themaintenanceonoperatingandlimitingcontrolsonlyrequiresvisualinspectionofthe

deviceforevidenceofwear,corrosion,etc.Iftheswitchisamercurybulbtype,itshouldalsobe

checked.

LowAirPressureFuelCut-OffSwitch

Thisdeviceisusedtopreventburneroperationwhentheamountofcombustionairsuppliedtothe

furnaceisinsufficienttoprovidesafecombustionofthefuel.Abasicsketchofthisdeviceisshownin

Fig.6.Thedeviceconsistsofasealedhousingdividedintwobyaflexiblediaphragmwhichis

connectedtoaswitchcontrollingthepowersupplytothefuelvalve.One

sideofthehousingisopentoatmosphere,theothersideisconnectedto

thedischargesideoftheforceddraftfan.Whenthefanisnotinoperation

orwhenitdevelopsinsufficientairpressure,thespringactingonthe

diaphragmwillkeeptheswitchopenandpowersupplytothefuelvalveis

notpossible.

Whenthefanisstartedandcomesuptospeed,sufficientairshouldbe

forcedintothefurnacetobuildupenoughpressurefortheairenteringthe

controltomovethediaphragmagainsttheforceofthespringandtoclose

theswitch.Thiswillallowthefuelvalvetobeenergizedandtheburnerto

belit.Ifduringoperationtheamountofcombustionairsuppliedwould

dropoffbelowthesafeminimumrequiredduetoamalfunctionofthefan,

thepressureoftheairwilldropaswell.Thecut-offswitchwillopen,de­

energizingthefuelvalve,andtheburnerwillceasefiring.

TESTThetestingofthelowairpressurecut-offismorecomplicated.Itisnecessarytotakemanual

controloftheprogrammer,ifpossible.Atestlightwithpowersourceshouldbeattachedtotheterminals

ofthecontrol.Withthefaninoperationandthe

burnerdamperinwideopenpositionformaximum

airflowandminimumpressure,thecontactsofthe

cut-offshouldbeclosedandthelightburning.By

restrictingtheairintaketothefan,thecut-offpoint

ofthecontrolcanbefound.

LowGasPressureFuelCut-OffSwitch

Thissafetycontroldeviceworksonthesame

principleasthelowairpressurecut-off.If,forany

reason,thepressureofthegassuppliedtotheburner

dropsbelowaminimumvalue,whichindicates

insufficientgasfbrsafecombustion,theswitchopens

up,andthefuelsupplyiscutoff.TheswitchinFig.

7consistsofadiaphragmorbellowswithpressurefromthefuelactingonitslowersideandthe

opposingforceofthespringactingonitsupperside.Ifthepressureofthefueldropsbelowasafelevel,

theleafspringwilldrop,openingtheswitchtothesolenoidoperatingthegasvalve.Thevalvethen

closes,shuttingdowntheburner,preventinganexplosiveconditionintheboilerduetoanunstable

flame.

TESTThelowgaspressurecut-offcanbetestedduringtheoperationoftheboilerbyslowlyclosing

themaingascock.Observethepressuregageonthegasline.Whenthepressureinthelinedropstothe

cut-offpoint,theburnervalveshouldshutautomatically

PRINCIPLE:cutsofffuelsupplywhenthepressureisatorabovethesetpressure.Iftheoperating

rangewasbetween5.5and8andthepressureofthefuelwasrising:analarmwouldbesentwhengas

pressurereached8.25.Ifthepressurecontinuedtorise,thefuelwouldbeshutoffwhenpressurereached

8.75.Allthesemeasurementsareinpsig.

TEST:

b.Lowgaspressurecutoff.(5marks)

PRINCIPLE:apressureoperatedswitchwhichpreventstheburnerfromoperatingwhenthegas

pressureinthesupplylinedropsbelowthepressurenecessarytomaintainastableflameattheburner.

Worksthesameasthehighpressurecontrolbutsendsfirstanalarmandthenshutsfueloffaspressure

isdropping.Aswiththeabovenumbers:analarmwouldbesentwhenpressuredropsto5.25andfuelis

shutoffat5.0.Again,themeasurementsareinpsig.

TEST:

c.Lowairpressurecutoff.(5marks)

ANSWER

PRINCIPLE:-worksinsameprincipleasthelowgaspressurefuelcutoff.Iftheamountofair

suppliedtotheburnerdropsbelowtheminimumrequiredforsafecombustion,thesupplypressurein

theducttotheburnerdropsoffaccordingly,thentheswitchopensupandthefuelsupplyiscutoff.

TEST:

7.Listthenecessarycontrolsforanautomaticallycontrolledlowpressuresteamheating

boileranddescribethepurposeandmethodofoperationofeachcontrol.(10marks)

ANSWER:4thclassc74

SAFETYDEVICESANDINTERLOCKS

Interlocksmaybedefinedasanumberofelectricalswitchesconnectedinseries,whosepurposeisto

protectapieceofequipment,orsystem,frombeingoperatedinanunsafecondition.Ifallconditionsor

measurementsrelevanttosafeoperationoftheequipment,suchasaboiler,aresatisfied,itwillkeep

operating.Ifoneormoreunsafeconditions,suchaslowdrumlevel,etc.,shouldoccur,therespective

relayorelectricalswitchwillopen,andtheprocessorequipmentwillshutdown.Someoftheelectrical

relaysorautomaticallyoperatedswitchesusedonboilersaredescribedbelow.Ineachcase,theswitchis

locatedintheelectricalcircuitsupplyingpowertoanelectricallyoperatedvalveinthemain(orpilot)

fuelgasline.Ifanyoftheseswitchesopensthevalvewillclose,thusputtingtheboilerintoasafe,non­

operatingcondition.

LowAirPressureFuelCutoffSwitch

Thelowairpressureswitchisasafetydevicemountedonboilerswithforceddraftfansorblowers.Itis

usedtoshutdowntheboilerfuelsupplywhenthesupplyofcombustionairisinsufficienttoprovidea

stableflame.Fig.1isabasicillustrationofthedevice.

Theswitchconsistsofasealedhousingdividedintotwosectionsbyadiaphragmwhichisconnectedto

aswitchcontrollingthepowersupplytothefuelvalve.Onesideofthehousing,containingthespring,is

opentotheatmosphere.Theothersideisconnectedtothedischargeoftheforceddraftfan.Ifthefanis

notinoperation,orwhenitdevelopsinsufficientdischargepressure,thespringactingontheleftsideof

thediaphragmwillkeeptheswitchopentothefuelvalvepowersupply.

Whenthefanisstarted,andtheforceduetotheairpressureexceedsthespringforce,thediaphragm

willmovetotheleftandclosetheswitch.Thiswillpermitthefuelvalvetobeenergizedandtheburner

tobelitiftheotherinterlocksareclosed.Shouldtheairsupplydropbelowasafeminimumdueto

malfunctionofafanduringboileroperation,thepressureoftheairwilldropandthespringwillopen

theelectricalcircuittothefuelvalvecausingtheburnertobeshutdown.

LowGasPressureFuelCutoffSwitch

Thissafetycontroldeviceoperatesonthesameprincipleasthelowairpressurefuelcutoffswitch.Ifthe

fuelgaspressuredropsbelowthevaluerequiredtomaintainastableflame,theswitchwillopenthe

electricalcircuittothefuelgasvalve.Asimilarlowoilpressureswitchcanbeusedonoil-firedboilers.

FlameFailureDetector

If,foranyreason,theburnerflameshouldgooutduringtheoperationofanoil-orgas-firedboiler,itis

necessarytoshutoffthefuelvalveimmediately.Thiswillpreventunbumedfuelfromcollectinginthe

furnaceandcausinganexplosion.Aflamefailuredetectorservesthepurpose.

Onetypeofflamefailuredevice,illustratedinFig.2usesaleadsulphidecellwhichissensitivetothe

infraredraysradiatingfromtheflame.Itsresistancetocurrentflowdecreasesastheintensityofinfrared

radiationincreases.Iftheflameshouldgooutthenthecellwillnolongersensetheradiationcausingits

resistancetocurrentflowtoincreaseandthefuelvalvetoclose.Theleadsulphidecell,commonly

calleda"scanner”mustbemountedonthefurnacefrontinsuchawaythatithasaclearviewofthe

flamethrougharestrictedorifice.Thetubeorrestrictionwillreducetheeffectsofradiationfromthehot

refractorytowhichthisdetectorisalsosensitive.

Theultravioletsensororscannerissensitivetoultravioletradiationfromtheflame'sprimary

combustionzone.Iftheflamegoesoutthepowersupplytothefuelvalvewillbeopenedandthevalve

willclose.

Mostpackagedboilersuseascanner

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论