版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
摘要该旅馆为五层框架结构,设计包括建筑造型和结构计算。本工程抗震烈度为七度,场地为上海场地土,基本风压为0.55,地面粗糙度属于C类。框架结构主要承重构件为梁、柱,通常计算时把梁和柱的节点的连接方式看为刚接。为计算分析方便起见,可把实际框架结构看成纵横两个方向的平面框架。本设计的计算主要包括恒荷载计算、活荷载计算、风荷载计算,水平地震荷载计算及其作用下的侧移验算,楼板的配筋计算,楼梯设计及配筋计算,二次分配法计算恒荷载和活荷载作用下框架的弯矩、剪力、轴力计算,D值法计算风荷载作用下框架的内力。框架结构设计时,荷载效应组合采用简化的方法处理,即对所有可变荷载乘以荷载组合系数。本建筑物的基础为条形基础,选择了A、B两个轴线方向进行计算。这本计算书包括了板,梁,柱,楼梯,框架的所有计算内容。关键词:混凝土,框架,荷载,配筋,条形基础AbstractMygraduationprojectistodesignafive-layerframestructure,includingarchitecturaldesignandstructuralcalculation.Classificationforearthquake—resistanceofthisbuildingissevendegree.ThesiteisinShanghaiThemajorbearingmembersoftheframestructurearebeamsandcolumns.Usuallyweregardthejunctionsbetweenpostandbeamasrigidconnection.Tosimplifythecalculation,thepracticalframestructureisconsideredastwoflatframeswithverticalandhorizontaldirections.Themaintaskofthisprojectincludescalculationofconstantloadandliveload,sidewaycalculationunderwindloadandhorizontaleffectfromearthquake,floorandroofslabsreinforcement,stairsdesignandreinforcement,awningboardreinforcement.Theframebendingmoment,shearforceandnormalforcearecalculatedbysecondarydistributemethod.TheinternalforcesunderwindloadarecalculatedbyvalueDmethod.Whendecidingthedistributionofliveloads,Iconsidertheliveloadsspreadonallthebeams.Loadeffectcombinationisworkedoutinasimpleway,whichmeansthevariableloadsshouldmultiplythecoefficientforcombinationvalueofloads.Thefoundationisastripfoundation,IchooseframeAandBtocalculate.Thisbookincludestheconcretecalculationsofboards,beams,columns,stairsandfoundation.Keywords:concrete,frame,load,reinforcement,combinationofinternalforce,pilefoundation目录上海师范大学本科毕业论文(设计)诚信声明……………=1\*ROMANI上海师范大学本科毕业论文(设计)选题登记表…………=2\*ROMANII上海师范大学本科毕业论文(设计)指导记录表…………Ⅳ中文摘要及关键词………Ⅴ英文摘要及关键词………Ⅵ正文…………1第一章设计任务及要求…………………1一、设计原始资料…………1(一)工程概况…………1(二)设计条件…………1二、建筑设计任务及要求…………………1三、结构设计任务及要求…………………1第二章建筑设计总说明…………………2一、平面设计………………2(一)平面布置…………2(二)建筑结构方案……………………2(三)柱网布置…………2(四)平面组合…………2(五)交通组织及防火疏散设计………2二、剖面设计………………2(一)房间各部分高度……………2(二)各用途房间的楼地面做法及说明…………2(三)屋面构造做法及说明………3(四)墙体细部构造及说明………3三、立面设计………………3第三章结构方案设计总说明……………3一、结构方案的选择及结构布置…………3(一)结构方案的确定…………………3(二)基础类型的确定…………………3第四章结构内力计算……………………3一、构件尺寸确定………3二、荷载统计………………4(一)竖向荷载计算……………………4(二)四周维护墙体及相应构件荷载统计……………5(三)梁柱自重…………5三、板的计算………………5(一)屋面板的计算……………………5(二)楼面板的计算……………………6四、水平荷载作用下内力作用……………8(一)风荷载作用………8(二)水平地震作用下框架内力计算………………14(三)框架的侧移验算………………19五、竖向荷载作用下内力计算…………20(一)恒荷载作用下的内力计算……20(二)活荷载作用下的内力计算……28六、内力组合……………33(一)框架梁的内力组合……………33(二)框架柱的内力组合……………33第五章框架结构的配筋设计……………44一、框架梁配筋………44(一)纵向受力钢筋计算……………44(二)斜截面受剪承载力计算………45二、框架柱配筋…………48(一)纵向受力钢筋计算……………48(二)斜截面配筋……………………57第六章框架结构柱下基础设计…………61一、基础截面尺寸选择…………………61二、条基内力计算………62三、条形基础配筋计算…………………63第七章楼梯的设计………64一、设计资料……………64二、楼梯板计算…………65(一)基本尺寸………65(二)荷载计算………65(三)内力计算………65(四)截面承载能力计算……………65三、平台板计算…………66(一)荷载计算………66(二)内力计算………66(三)截面承载能力计算……………66四、平台梁计算…………67(一)基本尺寸………67(二)荷载计算………67(三)内力计算………67(四)正截面承载力计算……………67(五)斜截面承载能力计算…………68参考文献……………………69正文设计任务及要求一、设计原始资料(一)工程概况:该建筑为上海市某区某旅馆,总建筑平面面积约6000平方米。设计年限为50年。结构类型:框架结构,由A、B两部分组成,均为5层。层高除底层均为3.0M,底层为3.6M。基础选用条形基础。旅馆为经济便捷型旅馆,主要有客房,超市,餐厅等。该旅馆设有两个主楼梯(3.1M),一个次要楼梯(宽为2.5M)。楼梯的布置均已符合消防、抗震的要求。(二)设计条件:1、气象条件:常年东南风,基本风压W0=0.35KN/m2基本雪压S0=0.55KN/m22、水文、地质情况:土质为粘土,fk=160KN/M²,最高地下水位为地下2.5M,最低地下水位为5M。3、防火等级:二级4、抗震烈度为7度5、屋面活荷载0.5KN/m2楼面活荷取2KN/m26、施工及设备条件:根据现有的先进施工方案进行施工,设备明细表等具体见施工组织和附件。二、建筑设计任务及要求主要完成建筑总说明、平面、立面、剖面、构造详图、门窗详图、楼梯详图及结构施工图。建筑总面积约于6000m三、结构设计任务及要求1、楼面、屋面板的配筋计算2、梁、柱配筋计算及楼梯设计计算3、基础计算及配筋第二章建筑设计总说明一、平面设计(一)平面布置根据所需要建设的旅馆所处的位置,将对所要建设的旅馆进行施工平面布置。1.建筑结构方案对于建筑物的土质和所在地区的抗震等要求,选择框架结构,条形基础,具体见结构施工图。2.柱网布置柱间距分别为6.6m、2.7m,具体可见结构平面图。3.平面组合该旅馆由两部分组成,之间留有伸缩缝,中间走廊部分相通,用软组织材料进行填充,形成一个密封空间。两部分组成一L型建筑。4.交通组织及防火疏散设计在接待台旁边设有电梯,方便快捷。另外还三个楼梯,满足放火疏散要求。二、剖面设计(一)房间各部分高度净高和层高:净高为2.8M,层高为3M;室内外高差:0.45M;(二)各用途房间的楼地面做法及说明详见剖面图;(三)屋面构造做法及说明详见剖面图和详图;(四)墙体细部构造及说明外墙:200mm厚粘土空心砖,墙面为20mm内墙:200mm厚粘土空心砖,两侧均为三、立面设计(一)立面构造意图详见立面图(二)墙面做法普通的抹灰,涂刷涂料。第三章结构方案设计说明一、结构方案的选择及结构布置二、结构方案的确定:框架结构;三、基础类型的确定:交叉条形基础; 第四章结构内力计算一、构件尺寸确定1、楼板厚度确定2、按单向板来设计:L1=3300,h≥/40=3300/40=82.5mm,取h=100mm3、框架梁截面尺寸确定:主梁:取h=700mm,b=300mm,h/b=2次梁:取h=450mm,b=250mm,4、框架柱截面尺寸确定:N=L1×L2×层数×1.3=6.6×6×5×1.3=257.4KNN==0.9×14.3×A=257.4,则A=200000假设用方形柱,则,取a=500mm,验算:5、材料选择混凝土强度等级:除基础垫层混凝土选用C10外,基础及以上混凝土均选用C30钢筋级别:板内钢筋采用HPB235级钢筋,其余钢筋选用HRB335和HRB400级.二、荷载统计(一)竖向荷载计算:板面荷载屋面荷载恒荷载标准值面层水泥沙浆找平20×0.02=0.4SBS刚性防水层0.4保温层:80mm厚矿渣水泥0.08×14.5=1.16找坡层0.4屋面板0.14×25=3.5抹灰层0.02×17=0.346.2b.活荷载标准值按以上人屋面,取2.0②楼面荷载恒荷载标准值水磨石面层0.65楼面板0.14×25=2.5板底抹灰0.02×17=0.344.49活荷载标准值按“商场”一栏,取3.5(二)四周维护墙体及相应构件荷载统计:1.玻璃幕墙:5×1.5=7.5(三)梁柱自重:框架梁:0.3×(0.7-0.1)×25=4.510厚抹灰砂浆0.01×(2×0.3+2×0.7)×17=0.34合计4.84次梁:0.2×(0.45-0.1)×25=1.7510厚抹灰砂浆0.01×(2×0.2+2×0.45)×17=0.22合计23.柱:0.5×0.5×5×25+0.5×4×5×0。3=34.25三、单向板的计算1.梁板截面尺寸计算板厚h=140次梁h=450mmb=200mm框架梁h=700mmb=300mm2.配筋计算板荷载设计值板的计算跨度第一跨l。=2200-100-150+140/2=2020mm第二跨l。=ln=2200-250=1950mm单向板配筋计算(屋面)位置边支座边跨跨中第一内支座第一跨跨中内支座弯矩系数-1/161/14-1/111/16-1/14弯矩设计值M()-2.082.39-3.041.952.220.0120.0140.0180.0110.013()81.695.2122.474.888.4实配钢筋@200@200@200@200@2003.纵向次梁配筋计算荷载设计值计算边跨度l。=ln+a/2=6000-120-150+240/2=5850mm中间跨l。=ln=6000-200=5800mm支座处按巨星截面,跨中按T形截面取b=l。/3=19501)正截面受弯承载力h=h-a=450-35=415mm第一内支座h=390mm位置边支座边跨跨中第一内支座第一跨跨中内支座弯矩系数-1/241/14-1/111/16-1/14弯矩设计值29.5450.65-64.4643.5649.78()0.0740.1320.1980.1120.149()203.2362.17510.51307.2408.7实配钢筋2B202B202B202B202B20次梁纵向受力钢筋2)斜截面受剪承载力计算位置边支座第一内支座中间支座剪力系数0.500.550.55V(KN)60.0966.6666.090.25246.93232.05246.930.773.7869.3473.78实配钢筋@200@200@200单向板屋盖计算板荷载设计值板的计算跨度第一跨l。=2050mm第二跨l。=ln=1950单向板配筋计算(屋面)位置边支座边跨跨中第一内支座第一跨跨中内支座弯矩系数-1/161/14-1/111/16-1/14弯矩设计值M()-2.112.483.161.97-2.240.0130.0150.0190.0120.013()88.4102129.281.688.4实配钢筋@200@200@200@200@2003.纵向次梁配筋计算荷载设计值计算边跨度l。=5850mm中间跨l。=ln=6000-200=5800mm支座处按巨星截面,跨中按T形截面取b=l。/3=19501)正截面受弯承载力次梁纵向受力钢筋位置边支座边跨跨中第一内支座第一跨跨中内支座弯矩系数-1/241/14-1/111/16-1/14弯矩设计值-35.9861.67-78.4953.0460.62()0.090.1640.210.160.18()243.93438.98541.45412.53464.1实配钢筋2B202B202B202B202B20四、水平荷载作用下内力作用(一)风荷载作用由于是现浇框架,而且每榀横向框架的侧移刚度相同,故意各榀框架所承受同样的风力,也即每榀框架承受风力范围在水平方向是:54/9=6m1.基本参数由设计条件,,按C类粗糙度,可查得风压高度系数在25、20、15、10和5m处分别为0.92、0.84、0.74、0.74、0.74;风压体型系数迎风面为+0.8,背风面为-0.5。2.荷载标准值计算(左风)由确定,A为相应高度范围的受荷面积。其中,,,,。图4.4.13.框架柱内力计算(采用D值法计算)⑴梁柱线刚度计算:各构件截面惯性矩:柱:主梁:,按T形梁计算,I=2=1.715其中取线刚度最大的构件作为参考,取其为1.0,其余与其相比所得即为相对线刚度。各构件截面惯性矩和相对线刚度表4.4构件截面惯性矩I()线刚度相对线刚度i1-5层梁1.02-5层柱0.4底层柱0.34图4.4.⑵求各柱剪力值:采用D值法计算,根据各柱的D值将剪力进行分配。计算过程详见下表。框架柱剪力计算表4.4第五层柱柱柱同柱V=1.38KN柱,,同柱V=1.75KN第四层柱柱柱同柱V=3.88KN柱,,同柱V=5.05KN第三层柱柱柱同柱V=5.97KN柱,,同柱V=7.93KN第二层柱柱柱同柱V=8.3KN柱,,同柱V=10.8KN第一层柱柱柱同柱V=7.94KN柱,,同柱V=6.74KN⑶各项反弯点高度yh框架柱反弯点高度计算表4.4.第五层柱柱柱同柱=0.43柱,,同柱=0.45y=0.43y=0.45第四层柱DE柱JK柱同柱=0.45柱,,同柱=0.5y=0.45y=0.5第三层柱CD柱IJ柱同柱=0.5柱,,同柱=0.5y=0.5y=0.5第二层柱BC柱HI柱同柱=0.5柱,,同柱=0.5y=0.5y=0.5第一层柱AB柱GH柱同柱=0.55柱,,同柱=0.55y=0.55y=0.55⑷求弯矩由下面公式求出柱上下两端弯矩:上柱:下柱:再由节点平衡条件和梁的线刚度比,求出梁端弯矩,即可绘出框架M图。图4.4.3水平风荷载作用下M图(K图4.4.图4.4.(二)水平地震作用下框架内力计算:1.水平地震作用标准值的计算:⑴框架的抗震等级由设计要求,抗震设防烈度为7度,房屋高度未超过30m,属于丙类建筑,则该框架的抗震等级为三级。⑵场地和特征周期值根据工程地质报告和土的类型划分,可判定为Ⅲ类场地。由设计地震分组为第一组,可查得特征周期值。⑶各层重力荷载代表值计算(取计单元6m宽度范围内的重力荷载代表值)①顶层:G=屋面荷载+0.5雪载+纵横梁自重+0.5柱自重+0.5墙自重屋面荷载=6×6.6×5×=1227.6KN0.5雪载=0.5×0.2×6×33=19.8KN纵横梁自重:纵梁=4.875×6.6×6=160.88KN,横梁=4.875×6×6=175.5KN次梁=2.25×6×10=135KN0.5柱重=0.5×6×34.25=102.75KN0.5墙重=0.5×7.5×6×2=45KNG=1227.6+160.8+19.8+175.5+5.1+135+102.75+45=1886.53KN②2-4层:G=楼面恒载+0.5楼面活载+纵横框架梁自重+0.5上柱自重+0.5上墙自重+0.5下柱自重+0.5下墙自重楼面恒载=4.49×6×33=889KN0.5楼面活载=0.5×3.5×33×6=346.5KN纵横梁自重=160.88+175.5+135=471.38KN柱重=0.5上柱自重+0.5下柱自重=34.25×6=205.5KN墙重=0.5上墙重+0.5下墙重=7.5×2×6=90KNG=889+346.5+471.38+205.5+90=2002.38KN③底层:G=楼面恒载+0.5楼面活载+纵横框架梁自重+0.5上柱自重+0.5上墙自重+0.5下柱自重+0.5下墙自重楼面恒载=4.49×6×33=889KN0.5楼面活载=0.5×3.5×33×6=346.5KN纵横梁自重=160.88+175.5+135=471.38KN0.5上柱自重=0.5×34.25×6=102.75KN0.5柱自重=0.5×34.25×6×(5.95/5)=122.27KN0.5上墙自重=45KN0.5下墙自重=45×5.95/5=53.55KNG=889+346.5+471.38+102.75+122.27+45+53.55=2030.45KN⑷结构自振周期T1 位置层间剪力Xi5层1886.531886.53591210.031960.181.924层2002.383888.91591210.0658131.758.673层2002.385891.29591210.0996199.4319.862层2002.387893.67591210.1335267.3135.681层2030.459924.41422770.1679336.2057.24T=0.704<5=1.75s⑸求地震影响系数,==0.043⑹计算水平地震作用标准值:因T1<Tg,则不需要考虑顶点附加作用。水平地震作用标准值计算位置5层1886.5325.9548955.450.31112.444层2002.3820.9541949.860.2797.933层2002.3815.9531937.960.2072.542层2002.3810.9521926.060.1450.781层1886.532.9512081.180.0829.022.水平地震作用产生的框架内力图4.4.⑴水平地震作用下的框架剪力值各层框架柱剪力表4.4.位置5层4层3层2层1层112.44200.37282.91333.69362.71A柱15.729.339.446.554.4B柱20.438.151.260.463.5⑵各项反弯点高度yh(与风荷载相同)框架柱反弯点高度计算表4.4位置5层4层3层2层1层ABABABABAB2.552.552.552.552.945.880.430.450.450.50.50.50.50.50.550.55(其中C、D分别与B、A相同)⑶求弯矩由下面公式求出柱上下两端弯矩:上柱:下柱:再由节点平衡条件和梁的线刚度比,求出梁端弯矩,即可绘出框架M图。图4.4.7水平地震荷载作用下M图(KN·图4.4.8图4.4.9(三)框架的侧移验算:⑴风荷载作用下的侧移验算(对于C30混凝土,)风荷载作用下的框架侧移验算表4.4位置限值5层9.959.10.171/294111/4004层27.959.10.471/106383层43.859.10.741/67562层59.759.11.041/49501层77.159.11.31/3846顶点位移1/70321/500⑵水平地震作用下的侧移验算地震荷载作用下的框架侧移验算表4.4位置5层112.459.12.241/22331/5504层210.3759.14.181/11933层282.9159.15.631/8872层333.6959.16.641/7531层362.7142.38.571/589五、竖向荷载作用下内力计算(一)恒荷载作用下的内力计算1.计算单元选取图4.5.2.荷载计算⑴构件自重(均为均布荷载形式):为墙重,;梁重,次梁⑵楼板重=4.49×6×2.2=59.27KN/m,屋面板重=6.2×6×2.2=81.84KN/m;⑷M1、M2分别为偏心力矩顶层:M1=7.02KN·m,1-4层:M1=10.39KN·m3.恒载作用下框架计算简图:4.5.24.计算各梁柱内力(采用弯矩二次分配法)⑴顶层:图4.5.3顶层示意图,=-146.58结点:,结点:结点:,⑵中间层:图4.5.4中间层示意图结点:结点:结点:,⑶底层:结点:结点:结点:,⑷弯矩的传递与分配图4.5.5弯矩二次分配(KN⑸绘M、V、N图图4.5.6图4.5.N图(KN)(二)活荷载作用下的内力计算图4.5.104.计算各梁柱内力(采用弯矩二次分配法)⑴顶层:,⑵中间层:⑷弯矩的传递与分配图4.5.11弯矩二次分配(KN⑸绘M、V、N图图4.5.12图4.5.13图4.5.14六、内力组合:考虑5种荷载组合:①②③(小于组合2故表格中不做计算)④⑤(一)框架梁的内力组合(二)框架柱的内力组合五层梁ABBC截面位置A跨中B左B右跨中内力种类MVMMVMVM恒载-54.0178.6370.5374.79-84.92-34.5614.31-24.9活载-13.5218.9216.9216.65-19.87-4.44.56-1.32风载(左)4.08-1.123.3-1.121.47-1.09风载(右)-4.081.12-3.31.12-1.471.09地震荷载(左)40.68-11.133.9432.78-11.1314.75-10.93地震荷载(右)-40.6811.13-3.94-32.7811.13-14.7510.931.2恒+1.4活-83.74120.844108.324113.058-129.722-47.63223.556-31.7281.35恒+0.98活-86.1631124.6921111.7971117.284-134.115-50.96823.7873-34.90861.2恒+1.26(活+风左)-76.7064116.784114.885-128.351-45.163821.54421.2恒+1.26(活+风右)-86.988119.6064106.569-125.529-48.868224.2911.2恒+1.26(活+风)-86.988119.6064114.885-128.351-48.868224.2911.2(恒+0.5活)+1.3地左-20.0491.23999.91142.352-128.295-24.9375.699-30.6721.2(恒+0.5活)+1.3地右-125.808120.17789.66657.124-99.357-63.28734.117-30.6721.2(恒+0.5活)+1.3地-125.808120.17799.91142.352-128.295-63.28734.117-30.6720.75<1.2(恒+0.5活)+1.3地>-94.35690.1327574.9325106.764-96.2213-47.465325.58775-23.004M设计值-94.36124.69111.80117.28-134.11-50.9725.59-34.91框架梁的内力组合(五层)表4.6框架梁的内力组合(四层)表4.6四层梁ABBC截面位置A跨中B左B右跨中内力种类MVMMVMVM恒载-57.5271.2857.9865.99-73.85-24.612.22-16.35活载-18.418.9212.9719.68-19.6-3.324.56-0.24风载(左)13.29-3.3210.95-3.324.92-3.64风载(右)-13.293.32-10.953.32-4.923.64地震荷载(左)90.54-26.941.7487.27-26.9439.27-29.09地震荷载(右)-90.5426.94-1.74-87.2726.94-39.2729.091.2恒+1.4活-94.784112.02487.734106.74-116.06-34.16821.048-19.9561.35恒+0.98活-95.684114.769690.9836108.3729-118.906-36.463620.9658-22.30771.2恒+1.26(活+风左)-75.4626105.192117.7818-117.499-27.50415.82321.2恒+1.26(活+风右)-108.953113.558490.1878-109.133-39.902424.9961.2恒+1.26(活+风)-108.953113.5584117.7818-117.499-39.902424.9961.2(恒+0.5活)+1.3地左37.63861.86679.62204.447-135.40219.539-20.417-19.7641.2(恒+0.5活)+1.3地右-197.766131.9175.096-22.455-65.358-82.56355.217-19.7641.2(恒+0.5活)+1.3地-197.766185.88679.62204.447-189.378-82.56374.795-19.7640.75<1.2(恒+0.5活)+1.3地>-148.325139.414559.715153.3353-142.034-61.922356.09625-14.823M-148.32139.4190.98153.34-142.03-61.9256.10-22.31框架梁的内力组合(三层)表4.6三层梁ABBC截面位置A跨中B左B右跨中内力种类MVMMVMVM恒载-54.271.160.8963.67-74-25.1212.22-16.87活载-17.8819.1813.419.33-19.61-3.414.56-0.33风载(左)24.33-5.5920.22-5.599.12-6.74风载(右)-24.335.59-20.225.59-9.126.74地震荷载(左)140.09-40.37.7125.88-40.356.68-41.99地震荷载(右)-140.0940.3-7.7-125.8840.3-56.6841.991.2恒+1.4活-90.072112.17291.828103.466-116.254-34.91821.048-20.7061.35恒+0.98活-90.6924114.781495.3335104.8979-119.118-37.253820.9658-23.09791.2恒+1.26(活+风左)-56.913102.4434126.237-120.552-22.949411.91721.2恒+1.26(活+风右)-118.2246116.530275.2826-106.465-45.931828.9021.2恒+1.26(活+风)-118.2246116.5302126.237-120.552-45.931828.9021.2(恒+0.5活)+1.3地左106.34944.43891.118251.646-152.95641.494-37.187-20.4421.2(恒+0.5活)+1.3地右-257.885149.21871.098-75.642-48.176-105.87471.987-20.4421.2(恒+0.5活)+1.3地-257.885166.18391.118251.646-169.921-105.87462.12-20.4420.75<1.2(恒+0.5活)+1.3地>-193.41375124.637368.3385188.7345-127.441-79.405546.59-15.3315M-193.41124.6495.33188.73-127.44-79.4146.59-23.10框架梁的内力组合(二层)表4.6二层梁ABBC截面位置A跨中B左B右跨中内力种类MVMMVMVM恒载-54.3671.1260.6163.89-74.01-25.0812.22-16.83活载-18.0119.1813.2919.42-19.61-3.364.56-0.28风载(左)35.76-10.1130.99-10.1113.95-10.33风载(右)-35.7610.11-30.9910.11-13.9510.33地震荷载(左)186.04-52.0214.19157.28-52.0270.77-52.42地震荷载(右)-186.0452.02-14.19-157.2852.02-70.7752.421.2恒+1.4活-90.446112.19691.338103.856-116.266-34.821.048-20.5881.35恒+0.98活-91.0358114.808494.8477105.2831-119.131-37.150820.9658-22.99491.2恒+1.26(活+风左)-42.86796.7722140.1846-126.259-16.75267.39381.2恒+1.26(活+风右)-132.9822122.249462.0898-100.782-51.906633.42541.2恒+1.26(活+风)-132.9822122.2494140.1846-126.259-51.906633.42541.2(恒+0.5活)+1.3地左165.81429.22699.153292.784-168.20459.889-50.746-20.3641.2(恒+0.5活)+1.3地右-317.89164.47862.259-116.144-32.952-124.11385.546-20.3641.2(恒+0.5活)+1.3地-317.89146.53899.153292.784-150.264-124.11349.328-20.3640.75<1.2(恒+0.5活)+1.3地>-238.4175109.903574.36475219.588-112.698-93.084836.996-15.273M-238.42122.2594.85219.59-126.26-93.0837.00-22.99框架梁的内力组合(一层)表4.6一层梁ABBC截面位置A跨中B左B右跨中内力种类MVMMVMVM恒载-47.8670.5765.2861.05-74.56-26.1112.22-17.86活载-15.8519.0715.0917.98-19.72-3.824.56-0.74风载(左)62.49-17.3852.23-17.3823.52-17.42风载(右)-62.4917.38-52.2317.38-23.5217.42地震荷载(左)241.17-68.4314.8210.45-68.4394.7-70.15地震荷载(右)-241.1768.43-14.8-210.4568.43-94.770.151.2恒+1.4活-79.622111.38299.46298.432-117.08-36.6821.048-22.4681.35恒+0.98活-80.144113.9581102.9162100.0379-119.982-38.992120.9658-24.83621.2恒+1.26(活+风左)1.334486.8134161.7246-136.218-6.51-1.53961.2恒+1.26(活+风右)-156.1404130.61130.105-92.4204-65.780442.35881.2恒+1.26(活+风)-156.1404130.611161.7246-136.218-65.780442.35881.2(恒+0.5活)+1.3地左246.5797.167106.63357.633-190.26389.486-73.795-21.8761.2(恒+0.5活)+1.3地右-380.463185.08568.15-189.537-12.345-156.734108.595-21.8761.2(恒+0.5活)+1.3地-380.463135.256106.63357.633-140.434-156.73436.965-21.8760.75<1.2(恒+0.5活)+1.3地>-285.35101.4479.97268.22-105.33-117.5527.72-16.41M设计值-285.35130.61102.92268.22-136.22-117.5542.36-24.84框架柱的内力组合(五层)表4.6五层柱A柱B柱截面位置上端下端层间上端下端层间内力种类MNMNVMNMNV恒载49.57-114.1431.25-135.98-26.94-36.71-127.4-21.2-149.1519.3活载12.84-24.379.53-24.37-19.2-10.91-35.14-8.02-35.1419.87风载(左)-4.081.12-2.311.120.71-4.77-0.03-3.06-0.030.87风载(右)4.08-1.122.31-1.12-0.714.770.033.060.03-0.87地震荷载(左)-40.6811.13-22.8611.1321.18-47.53-0.2-30.38-0.225.97地震荷载(右)40.68-11.1322.86-11.13-21.1847.530.230.380.2-25.971.2恒+1.4活︳Mmax︳77.46-171.09-59.21-59.33-202.0850.98Nmax50.84-197.29-59.21-36.67-228.18Nmin-59.21-59.33-202.081.35恒+0.98︳Mmax︳79.5027-177.97-207.46-60.25-206.4345.53Nmax51.53-207.46-55.19-36.48-235.79Nmin-207.46-55.19-60.25-206.431.2恒+1.26(活+风)80.8032-169.0952.42-195.29-57.41-51.79-197.12-31.69-223.2249.29NmaxNmin1.2(恒+0.5活)+1.3地120.072-166.0672.94-192.27-71.38-112.4-174.2-69.7-200.368.8Nmax11.2-173.79.2-199.81.3Nmin14.30-137.1213.50-163.33框架柱的内力组合(四层)表4.6四层柱A柱B柱截面位置上端下端层间上端下端层间内力种类MNMNVMNMNV恒载22.01-241.2824.88-263.03-15.63-14.66-279.46-16.51-301.2110.39活载8.18-49.018.6-49.01-5.59-7.01-70.01-7.95-70.014.99风载(左)-10.984.44-7.654.442.07-12.810.29-10.050.292.54风载(右)10.98-4.447.65-4.44-2.0712.81-0.2910.05-0.29-2.54地震荷载(左)-67.6838.07-55.3838.0741.02-96.161.95-78.681.9558.28地震荷载(右)67.68-38.0755.38-38.07-41.0296.16-1.9578.68-1.95-58.281.2恒+1.4活︳Mmax37.86-358.1541.90-384.25-26.58-27.41-433.37-30.94-459.4719.45NmaxNmin1.35恒+0.98活︳Mmax︳37.73-373.7642.02-403.12-26.58-26.66-445.88-30.08-475.2418.92NmaxNmin1.2恒+1.26(活+风)50.55-356.8850.33-382.98-28.41-10.28-423.93-17.17-450.0321.96NmaxNmin22.88-345.6931.05-371.79-23.19-42.57-423.20-42.49-449.3015.561.2(恒+0.5活)+1.3地119.30-368.43107.01-394.53-75.44103.21-379.8977.70-405.9991.23NmaxNmin-56.66-269.45-36.98-295.5531.22-146.81-374.82-126.87-400.92-60.30框架柱的内力组合(三层)表4.6三层柱A柱B柱截面位置上端下端层间上端下端层间内力种类MNMNVMNMNV恒载24.88-368.2425.51-389.99-16.49-16.51-301.21-16.34-431.670.95活载8.6-73.648.51-73.64-5.7-7.29-104.86-7.22-104.864.84风载(左)-16.6810.03-14.1910.033.43-19.291.44-18.511.444.2风载(右)16.68-10.0314.19-10.03-3.4319.29-1.4418.51-1.44-4.2地震荷载(左)-84.7178.37-84.7178.3756.47-103.853.64-103.853.6469.23地震荷载(右)84.71-78.3784.71-78.37-56.47103.85-3.64103.85-3.64-69.231.2恒+1.4活︳Mmax︳41.90-544.9842.53-571.08-27.77-30.02-508.26-29.72-664.817.92NmaxNmin1.35恒+0.98活︳Mmax︳42.02-569.2942.78-598.65-27.85-29.43-509.40-29.13-685.526.03NmaxNmin1.2恒+1.26(活+风)61.71-547.3159.21-573.41-31.29-4.69-495.39-5.38-651.9412.53NmaxNmin19.68-522.0423.46-548.14-22.65-53.30-491.76-52.03-648.311.951.2(恒+0.5活)+1.3地145.14-587.95145.84-614.05-96.62110.82-429.10111.07-585.6594.04NmaxNmin-75.11-384.19-74.41-410.2950.20-159.19-419.64-158.95-576.1994.04框架柱的内力组合(二层)表4.6二层柱A柱B柱截面位置上端下端层间上端下端层间内力种类MNMNVMNMNV恒载24.59-495.2229.87-516.97-18.15-16.94-540.39-19.97-562.1412.3活载8.82-98.2610.33-98.26-6.38-7.5-139.74-8.78-139.745.43风载(左)-21.5720.14-21.5720.144.79-26.431.66-26.431.665.87风载(右)21.57-20.1421.57-20.14-4.7926.43-1.6626.43-1.66-5.87地震荷载(左)-101.33130.39-101.33130.3967.55-124.24.04-124.24.0482.8地震荷载(右)101.33-130.39101.33-130.39-67.55124.2-4.04124.2-4.04-82.81.2恒+1.4活︳Mmax︳41.86-731.8350.31-757.93-30.71-30.83-844.10-36.26-870.2022.36NmaxNmin1.35恒+0.98活︳Mmax︳41.84-764.8450.45-794.20-30.75-30.22-866.47-35.56-895.8321.93NmaxNmin1.2恒+1.26(活+风)67.80-743.4576.04-769.55-35.853.52-826.63-1.72-852.7314.21NmaxNmin13.44-692.7021.68-718.80-23.78-63.08-822.45-68.33-848.5529.001.2(恒+0.5活)+1.3地166.53-822.73173.77-848.83-113.42136.63-737.56132.23-763.66-89.62NmaxNmin-96.93-483.71-89.69-509.8162.21-186.29-727.06-190.69-753.16125.66框架柱的内力组合(一层)表4.6一层柱A柱B柱截面位置上端下端层间上端下端层间内力种类MNMNVMNMNV恒载13.73-621.656.87-643.4-4.48-9.44-671.41-4.72-693.163.08活载4.83-122.782.42-122.78-1.58-4.05-174.73-2.03-174.731.32风载(左)-40.9237.52-52.0837.526.74-49.321.7-60.31.77.44风载(右)40.92-37.5252.08-37.52-6.7449.32-1.760.3-1.7-7.44地震荷载(左)-139.84198.82-209.76198.8276-180.955.76-230.295.7689.4地震荷载(右)139.84-198.82209.76-198.82-76180.95-5.76230.29-5.76-89.41.2恒+1.4活23.238-917.87211.632-943.972-7.588-16.998-1050.314-8.506-1076.4145.544NmaxNmin1.35恒+0.98活23.2689-959.55211.6461-988.914-7.5964-16.713-1077.639-8.3614-1107.0015.4516NmaxNmin1.2恒+1.26(活+风)74.121-947.95876.914-974.058-15.859245.71-1027.9967.76-1054.0914.7336Nmax1.13-78.57-1023.71-84.20-1049.81-4.0152Nmin1.2(恒+0.5活)+1.3地201.166-1078.11282.384-1104.21-105.124221.48-918.02292.50-944.12120.71Nmax-162.42-561.18-262.99-587.2892.48-248.99-903.04-306.26-929.14120.71Nmin第五章框架结构的配筋设计一、框架梁配筋(一)纵向受力钢筋计算1.各层框架梁控制截面的弯矩设计值框架梁弯矩设计值(KN·m)表5截面位置AB跨BC跨A跨中B左B右跨中5层-86.99111.8117.28-50.97-34.9-94.3674.93106.76-47.47-234层-108.9590.98117.78-39.9-22.313层-118.2295.33126.24-45.93-23.12层-132.9894.85140.18-51.91-22.991层156.14102.92161.72-65.7824.84-285.3579.97268.22-117.55-16.41由于2、3、4层M比较接近且与1层相差不大,则2、3、4层按1层配筋计算。2.配筋计算顶层框架梁配筋计算表5.1控制截面A左AB跨中B左B右BC跨中M设计值-94.36111.8117.28-50.97-34.9250×6202200×665250×620250×320900×3650.07120.00810.08930.15060.0084526563660574320实配钢筋763(318)318318318318注:(C30混凝土),(HRB335级)底层框架梁配筋计算表5.1控制截面A左AB跨中B左B右BC跨中M设计值-285.35102.92268.22-117.55-24.84250×6202200×665250×620250×320900×3650.23530.00740.21920.40180.0059173951816201532228实配钢筋1847(328)763(318)328328318(二)斜截面受剪承载力计算(考虑地震作用组合)①剪力设计值:a.底层梁:AB:BC:b.二层梁:AB:BC:c.三层梁:AB:BC:d.四层梁:AB:BC:e.五层梁:AB:BC:框架梁剪力设计值(考虑地震作用)表5.1截面位置ABBCAB左屋面梁124.69-134.1124.29130.15535.53四层梁114.77-118.9125139.0758.99三层梁116.53-120.5528.9158.3977.43二层梁122.25-126.2633.4175.1592.35底层梁130.61-136.2242.36199.42117.7由上表可得,各截面剪力设计值为(KN)表5.1截面位置屋面梁四层梁三层梁二层梁底层梁AB134.11139.07158.39175.15199.42BC35.5358.9977.4392.35117.7②截面尺寸验算:,由,故满足要求。③抗剪计算:采用公式:(,)a.屋面梁配筋:AB:,无需配箍筋.BC:,无需配箍筋.b.四层梁配筋:AB:,可按照构造配筋,选取28@200,BC:,按照构造配筋.c.三层梁配筋:AB:,可按照构造配筋,选取28@200,BC:,可按照构造配筋.d.二层梁配筋:AB:,取s=200,则,选用28,,BC:,,可按照构造配筋.e.底层梁配筋:AB:,取s=200mm,,选用28@200箍筋,BC:取s=200mm,,选用28@200箍筋,二、框架柱配筋(一)纵向受力钢筋计算:截面尺寸:b×h=500mm×500mm,选用HRB335级钢筋,,,混凝土,对称配筋。则有,以此区分大小偏心受压。①五层:A柱a.非抗震设计时的内力组合,由组合表格可知都为大偏心受压,按M、N的相关关系,选出合适的组合:;.b.抗震设计内力组合。柱上端:柱下端:按抗震等级为三级要求,,则对这层框架柱抗震设计组合的有:柱上端:柱下端:c.配筋计算:控制配筋的内力组合值是:①105.66KN·m,146.13KN②80.8KN·m,169.09KN③51.53KN·m,207.456KN④64.18KN·m,169.2KN五层A柱配筋计算表5.2内力组合①②③④723478248379743498268391.0251.0371.0681.04612169717428730.0450.0520.0640.062661428138292钢筋选择318(763)_______________,,,.五层:B柱a.非抗震设计时的内力组合,由组合表格可知都为大偏心受压,按M、N的相关关系,选出合适的组合:;.b.抗震设计内力组合柱上端:柱下端:对这层框架柱抗震设计组合的有:柱上端:柱下端:c.配筋计算:控制配筋的内力组合值是:①98.9KN·m,153.32KN②61.38KN·m,176.29KN③60.25KN·m,206.43KN④36.48KN·m,235.8KN五层B柱配筋计算表5.2内力组合①②③④6453472921556653673121751.0271.051.0591.1058885905353980.0470.0540.0630.072596259210<0钢筋选择318(763)②四层:A柱a.非抗震设计时的内力组合:;.b.抗震设计内力组合:按抗震等级为三级要求,,则这层框架柱抗震设计组合的:c.配筋计算:控制配筋的内力组合值是:①50.55KN·m,356.88KN②42.02KN·m,403.12KN③104.99KN·m,324.22KN④94.17KN·m,347.19KN四层A柱配筋计算表5.2内力组合①②③④1421043242711621243442911.1131.1471.0531.0633835988177650.110.1240.10.107<0<0414295钢筋选择218(509)四层:B柱a.非抗震设计时的内力组合:;.b.抗震设计内力组合:对这层框架柱抗震设计组合的有:c.配筋计算:控制配筋的内力组合值是:①42.57KN·m,423.2KN②30.08KN·m,475.24KN③68.38KN·m,357.27KN④129.19KN·m,329.84KN四层B柱配筋计算表5.2内力组合①②③④10163191392121832114121.1521.2191.0861.0443443074356350.130.1460.110.101<0<072603钢筋选择318(763)③三层:A柱a.非抗震设计时的内力组合:;.b.抗震设计内力组合:按抗震等级为三级要求,,则对这层框架柱抗震设计组合的有:c.配筋计算:控制配筋的内力组合值是:①61.71KN·m,547.31KN②42.78KN·m,598.65KN③128.34KN·m,540.37KN④66.1KN·m,338.1KN三层A柱配筋计算表5.2内力组合①②③④11371238196133912582161.1381.21.0711.0853563154814390.1680.1840.1660.104<0<031179钢筋选择218(509)三层:B柱a.非抗震设计时的内力组合:;.b.抗震设计内力组合:对这层框架柱抗震设计组合的有:c.配筋计算:控制配筋的内力组合值是:①53.3KN·m,491.76KN②29.13KN·m,685.52KN③140.1KN·m,369.28KN④97.74KN·m,515.37KN三层B柱配筋计算表5.2内力组合①②③④10842379190128623992101.1421.2931.0461.0873522866234330.1510.2110.1140.158<0<063896钢筋选择318(763)④二层:A柱a.非抗震设计时的内力组合:;.b.抗震设计内力组合:按抗震等级为三级要求,,则对这层框架柱抗震设计组合的有:c.控制配筋的内力组合值是:①76.04KN·m,769.55KN②50.45KN·m,794.2KN③152.92KN·m,746.97KN④85.3KN·m,425.67KN二层A柱配筋计算表5.2内力组合①②③④9964205200119842252201.1541.2191.0811.0833423074484440.2370.2440.230.131<0<0275117钢筋选择218(509)二层:B柱a.非抗震设计时的内力组合:;.b.抗震设计内力组合:对这层框架柱抗震设计组合的有:c.配筋计算:控制配筋的内力组合值是:①68.33KN·m,848.55KN②35.56KN·m,895.83KN③167.81KN·m,662.78KN④116.36KN·m,672.02KN二层B柱配筋计算表5.2内力组合①②③④8140253173101602731931.1821.3061.0671.0953242834964160.2610.2750.2040.207<0<063896钢筋选择218(509)⑤底层:A柱a.非抗震设计时的内力组合:;.b.抗震设计内力组合:按抗震等级为三级要求,,则对这层框架柱抗震设计组合的有:c.配筋计算:控制配筋的内力组合值是:①11.65KN·m,988.9KN②76.91KN·m,974.06KN③259.8KN·m,1015.87KN④142.93KN·m,493.84KN底层A柱配筋计算表5.2内力组合①②③④127925628932992763091.8661.2781.11.0892643315085420.3040.2990.3120.152<0<01027488钢筋选择420(1256)底层:B柱a.非抗震设计时的内力组合:;.b.抗震设计内力组合:对这层框架柱抗震设计组合的有:c.配筋计算:控制配筋的内力组合值是:①8.36KN·m,1107KN②84.2KN·m,1049.81KN③269.1KN·m,868.59KN④81.76KN·m,854.81KN底层B柱配筋计算表5.2内力组合①②③④880310330281003303501.9981.2751.0831.0792603335625820.340.3230.2670.263<0<011871299钢筋选择422(1520)(二)斜截面配筋:①五层:a.非抗震剪力设计值:抗震剪力设计值:b.受剪斜截面要求:,均满足要求。c.箍筋计算:ⅰ.A柱:由,得,按构造配筋。ⅱ.B柱:由,得,按构造配筋。②四层:a.非抗震剪力设计值:抗震剪力设计值:b.受剪斜截面要求:,均满足要求。c.箍筋计算:ⅰ.A柱:由,得,按构造配筋。ⅱ.B柱:由,得,按构造配筋。③三层:a.非抗震剪力设计值:抗震剪力设计值:b.受剪斜截面要求:,均满足要求。c.箍筋计算:ⅰ.A柱:由,得,按构造配筋。ⅱ.B柱:由,得,按构造配筋。④二层:a.非抗震剪力设计值:抗震剪力设计值:b.受剪斜截面要求:,均满足要求。c.箍筋计算:ⅰ.A柱:由,得,按构造配筋。ⅱ.B柱:由,得,按构造配筋。⑤一层:a.非抗震剪力设计值:抗震剪力设计值:b.受剪斜截面要求:,均满足要求。c.箍筋计算:,取ⅰ.A柱:由,得,取28(101),按构造配。ⅱ.B柱:由,得,取,取2𮀁8(101),按构造配。3.配箍构造要求箍筋加密区:①加密区长度:≥500mm,≥,取800mm.②直径mm,取d=8mm.③间距:100mm④肢距:不大于250mm和20d=160mm.第六章框架结构柱下基础设计一、基础截面尺寸选择1.土质为粘土,,最高地下水位距地面2.5m,最低地下
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 汽车用包装箱项目可行性研究报告申请建议书
- 2025年中国阿维菌素市场深度调查及发展前景研究预测报告
- 2025-2030年中国网孔塔板项目投资可行性研究分析报告
- 复膜镜面卡纸行业市场发展及发展趋势与投资战略研究报告
- 中国起重机械行业市场发展现状及前景趋势与投资分析研究报告
- 使用LabVIEW进行电气工程项目管理与协作
- 2025年鲜菇项目可行性研究报告
- 划船衣行业行业发展趋势及投资战略研究分析报告
- 2025年特种塑料管道行业深度研究分析报告
- 2025年中国改装泡沫消防车行业投资分析及发展战略咨询报告
- 《康复评定技术》课件-第五章 运动控制
- 议论文8(试题+审题+范文+点评+素材)-2025年高考语文写作复习
- 【理特咨询】2024生成式人工智能GenAI在生物医药大健康行业应用进展报告
- 2025新人教版英语七年级下单词默写表(小学部分)
- 2025年春新外研版(三起)英语三年级下册课件 Unit6第1课时Startup
- 2025江苏苏州高新区狮山商务创新区下属国企业招聘9人高频重点提升(共500题)附带答案详解
- 平抛运动的经典例题
- 录井作业现场风险评估及控制措施
- 2025年度商会工作计划
- 社区管理与服务专业实习总结范文
- 施工现场5S管理规范
评论
0/150
提交评论