BiopotentialElectrodes:生物电的电极31、园日涉以成趣,门虽设而常关。32、鼓腹无所思。朝起暮归眠。33、倾壶绝余沥,窥灶不见烟。34、春秋满四泽,夏云多奇峰,秋月扬明辉,冬岭秀孤松。35、丈夫志四海,我愿不知老。BiopotentialElectrodes:生物电的电极BiopotentialElectrodes:生物电的电极31、园日涉以成趣,门虽设而常关。32、鼓腹无所思。朝起暮归眠。33、倾壶绝余沥,窥灶不见烟。34、春秋满四泽,夏云多奇峰,秋月扬明辉,冬岭秀孤松。35、丈夫志四海,我愿不知老。BiopotentialElectrodes
Electrode–ElectrolyteInterfaceElectrode Electrolyte(neutralcharge)C+,A-insolutionCCCA-A-C+C+e-e-CurrentflowC+:Cation A-:Anion e-:electronFairlycommonelectrodematerials:Pt,Carbon,…,Au,Ag,…Electrodemetalisuseinconjunctionwithsalt,e.g.Ag-AgCl,Pt-Ptblack,orpolymercoats(e.g.Nafion,toimproveselectivity)BiopotentialElectrodes
Electrode–ElectrolyteInterface
Electrode
Electrolyte(neutralcharge)C+,A-insolutionCCCA-A-C+C+e-e-CurrentflowC+:Cation A-:Anion e-:electronFairlycommonelectrodematerials:Pt,Carbon,…,Au,Ag,…Electrodemetalisuseinconjunctionwithsalt,e.g.Ag-AgCl,Pt-Ptblack,orpolymercoats(e.g.Nafion,toimproveselectivity)Electrode–ElectrolyteInterfaceGeneralIonicEquationsa)Ifelectrodehassamematerialascation,thenthismaterialgetsoxidizedandenterstheelectrolyteasacationandelectronsremainattheelectrodeandflowintheexternalcircuit.b)Ifanioncanbeoxidizedattheelectrodetoformaneutralatom,oneortwoelectronsaregiventotheelectrode.a)b)Currentflowfromelectrodetoelectrolyte:Oxidation(Lossofe-)Currentflowfromelectrolytetoelectrode:Reduction(Gainofe-)Thedominatingreactioncanbeinferredfromthefollowing:HalfCellPotentialAcharacteristicpotentialdifferenceestablishedbytheelectrodeanditssurroundingelectrolytewhichdependsonthemetal,concentrationofionsinsolutionandtemperature(andsomesecondorderfactors).
Halfcellpotentialcannotbemeasuredwithoutasecondelectrode.Thehalfcellpotentialofthestandardhydrogenelectrodehasbeenarbitrarilysettozero.Otherhalfcellpotentialsareexpressedasapotentialdifferencewiththiselectrode.ReasonforHalfCellPotential:ChargeSeparationatInterfaceOxidationorreductionreactionsattheelectrode-electrolyteinterfaceleadtoadouble-chargelayer,similartothatwhichexistsalongelectricallyactivebiologicalcellmembranes.MeasuringHalfCellPotentialNote:Electrodematerialismetal+saltorpolymerselectivemembraneSomehalfcellpotentialsStandardHydrogenelectrodeNote:Ag-AgClhaslowjunctionpotential&itisalsoverystable->henceusedinECGelectrodes!PolarizationIfthereisacurrentbetweentheelectrodeandelectrolyte,theobservedhalfcellpotentialisoftenalteredduetopolarization.OverpotentialDifferencebetweenobservedandzero-currenthalfcellpotentialsResistanceCurrentchangesresistanceofelectrolyteandthus,avoltagedropresults.ConcentrationChangesindistributionofionsattheelectrode-electrolyteinterfaceActivationTheactivationenergybarrierdependsonthedirectionofcurrentanddetermineskineticsNote:Polarizationandimpedanceoftheelectrodearetwoofthemostimportantelectrodepropertiestoconsider.NernstEquationWhentwoaqueousionicsolutionsofdifferentconcentrationareseparatedbyanion-selectivesemi-permeablemembrane,anelectricpotentialexistsacrossthemembrane.Forthegeneraloxidation-reductionreactionTheNernstequationforhalfcellpotentialiswhereE0:StandardHalfCellPotential E:HalfCellPotentiala:IonicActivity(generallysameasconcentration)n:Numberofvalenceelectronsinvolved Note:interestedinionicactivityattheelectrode(butnotetempdependencePolarizableandNon-PolarizableElectrodesPerfectlyPolarizableElectrodesTheseareelectrodesinwhichnoactualchargecrossestheelectrode-electrolyteinterfacewhenacurrentisapplied.Thecurrentacrosstheinterfaceisadisplacementcurrentandtheelectrodebehaveslikeacapacitor.Example:Ag/AgClElectrodePerfectlyNon-PolarizableElectrodeTheseareelectrodeswherecurrentpassesfreelyacrosstheelectrode-electrolyteinterface,requiringnoenergytomakethetransition.Theseelectrodesseenooverpotentials.Example:PlatinumelectrodeExample:Ag-AgClisusedinrecordingwhilePtisuseinstimulationUseforrecordingUseforstimulationAg/AgClElectrodeAg+Cl-Cl2RelevantionicequationsGoverningNernstEquationSolubilityproductofAgClFabricationofAg/AgClelectrodesElectrolyticdepositionofAgClSinteringprocessformingpelletelectrodesEquivalentCircuitCd
:capacitanceofelectrode-eletrolyteinterfaceRd
:resistanceofelectrode-eletrolyteinterfaceRs:resistanceofelectrodeleadwireEcell:cellpotentialforelectrodeFrequencyResponseCornerfrequencyRd+RsRsElectrodeSkinInterfaceSweatglandsandductsElectrodeEpidermisDermisandsubcutaneouslayerRuEheRsRdCdGelReEseEPRPCPCeStratumCorneumSkinimpedancefor1cm2patch:200kΩ1Hz200Ω1MHzAlterskintransport(ordeliverdrugs)by:Poresproducedbylaser,ultrasoundorbyiontophoresis100m100mNerveendingsCapillaryMotionArtifactWhyWhentheelectrodemoveswithrespecttotheelectrolyte,thedistributionofthedoublelayerofchargeonpolarizableelectrodeinterfacechanges.Thischangesthehalfcellpotentialtemporarily.WhatIfapairofelectrodesisinanelectrolyteandonemoveswithrespecttotheother,apotentialdifferenceappearsacrosstheelectrodesknownasthemotionartifact.ThisisasourceofnoiseandinterferenceinbiopotentialmeasurementsMotionartifactisminimalfornon-polarizableelectrodesBodySurfaceRecordingElectrodesMetalPlateElectrodes(historic)SuctionElectrodes(historicinterest)FloatingElectrodesFlexibleElectrodesElectrodemetalElectrolyteThinkoftheconstructionofelectrosurgicalelectrodeAnd,howdoeselectro-surgerywork?CommonlyUsedBiopotentialElectrodesMetalplateelectrodesLargesurface:Ancient,thereforestillused,ECGMetaldiskwithstainlesssteel;platinumorgoldcoatedEMG,EEGsmallerdiametersmotionartifactsDisposablefoam-pad:Cheap!(a)Metal-plateelectrodeusedforapplicationtolimbs.
(b)Metal-diskelectrodeappliedwithsurgicaltape.
(c)Disposablefoam-padelectrodes,oftenusedwithECGCommonlyUsedBiopotentialElectrodesSuctionelectrodesNostrapsoradhesivesrequired
precordial(chest)ECGcanonlybeusedforshortperiodsFloatingelectrodesmetaldiskisrecessedswimmingintheelectrolytegelnotincontactwiththeskinreducesmotionartifactSuctionElectrodeDouble-sidedAdhesive-taperingInsulatingpackageMetaldiskElectrolytegelinrecess(a)(b)(c)SnapcoatedwithAg-AgClExternalsnapPlasticcupTackPlasticdiskFoampadCapillaryloopsDeadcellularmaterialGerminatinglayerGel-coatedspongeCommonlyUsedBiopotentialElectrodesFloatingElectrodesReusableDisposable(a)Carbon-filledsiliconerubberelectrode.
(b)Flexiblethin-filmneonatalelectrode.
(c)Cross-sectionalviewofthethin-filmelectrodein(b).
CommonlyUsedBiopotentialElectrodesFlexibleelectrodesBodycontoursareoftenirregularRegularlyshapedrigidelectrodesmaynotalwayswork.Specialcase:infantsMaterial:-Polymerornylonwithsilver-Carbonfilledsiliconrubber(Mylarfilm)InternalElectrodesNeedleandwireelectrodesforpercutaneousmeasurementofbiopotentials(a)Insulatedneedleelectrode.
(b)Coaxialneedleelectrode.
(c)Bipolarcoaxialelectrode.
(d)Fine-wireelectrodeconnected
tohypodermicneedle,before
beinginserted.
(e)Cross-sectionalviewofskin
andmuscle,showingcoiled
fine-wireelectrodeinplace.Thelatest:BION–implantedelectrodeformusclerecording/stimulationAlfredE.MannFoundationFetalECGElectrodesElectrodesfordetectingfetalelectrocardiogramduringlabor,bymeans
ofintracutaneousneedles(a)Suctionelectrode.(b)Cross-sectionalviewofsuctionelectrodeinplace,showingpenetrationofprobethroughepidermis.(c)Helicalelectrode,whichisattachedtofetalskinbycorkscrewtypeaction.ElectrodeArraysExamplesofmicrofabricatedelectrodearrays.
(a)One-dimensionalplungeelectrodearray,
(b)Two-dimensionalarray,and
(c)Three-dimensionalarrayContactsInsulatedleads(b)BaseAg/AgClelectrodesAg/AgClelectrodesBaseInsulatedleads(a)Contacts(c)TinesBaseExposedtipMicroelectrodesWhy
MeasurepotentialdifferenceacrosscellmembraneRequirementsSmallenoughtobeplacedintocellStrongenoughtopenetratecellmembraneTypicaltipdiameter:0.05–10micronsTypesSolidmetal->TungstenmicroelectrodesSupportedmetal(metalcontainedwithin/outsideglassneedle)Glassmicropipette->withAg-AgClelectrodemetalIntracellularExtracellularMetalMicroelectrodesExtracellularrecording–typicallyinbrainwhereyouareinterestedinrecordingthefiringofneurons(spikes).Usemetalelectrode+insulation->goestohighimpedanceamplifier…negativecapacitanceamplifier!Microns!RCMetalSupportedMicroelectrodes(a)Metalinsideglass (b)GlassinsidemetalGlassMicropipetteAglassmicropipetelectrodefilledwithanelectrolyticsolution
(a)Sectionoffine-boreglasscapillary.
(b)Capillarynarrowedthroughheatingandstretching.
(c)Finalstructureofglass-pipetmicroelectrode.
Intracellularrecording–typicallyforrecordingfromcells,suchascardiacmyocyteNeedhighimpedanceamplifier…negativecapacitanceamplifier!heatpullFillwithintracellularfluidor3MKClAg-AgClwire+3MKClhasverylowjunctionpotentialandhenceveryaccuratefordcmeasurements(e.g.actionpotential)ElectricalPropertiesofMicroelectrodesMetalmicroelectrodewithtipplacedwithincellEquivalentcircuitsMetalMicroelectrodeUsemetalelectrode+insulation->goestohighimpedanceamplifier…negativecapacitanceamplifier!ElectricalPropertiesofGlassIntracellularMicroelectrodesGlassMicropipetteMicroelectrodeStimulatingElectrodes–Cannotbemodeledasaseriesresistanceandcapacitance(thereisnosingleusefulmodel)–
Thebody/electrodehasahighlynonlinearresponsetostimulation–Largecurrentscancause –
Cavitation –
Celldamage –
HeatingTypesofstimulatingelectrodesPacingAblationDefibrillationFeaturesPlatinumelectrodes:Applications:neuralstimulationModerndayPt-Irandotherexoticmetalcombinationstoreducepolarization,improveconductanceandlonglife/biocompatibilitySteelelectrodesforpacemakersanddefibrillatorsIntraocularStimulationElectrodesReference:LutzHesse,ThomasSchanze,MarcusWilmsandMarcusEger,“Implantationofretinastimulationelectrodesandrecordingofelectricalstimulationresponsesinthevisualcortexofthecat”,Graefe’sArchClinExpOphthalmol(2000)238:840–845Invivoneuralmicrosystems(FIBE):challengeInvivoneuralmicrosystems(FIBE):biocompatibility-variantInvivoneuralmicrosystems(FIBE):stateoftheartNeuralmicroelectrodesMEMS-MicrosystemsInstrumentationforneurophysiologyNeuralMicrosystemsIntroduction:neuralmicrosystems–––––ExternalelectrodesSubduralelectrodesMicro-electrodesMicrosensorsHumanlevelAnimallevelTissueslicelevelCellularlevelIntroduction:typesofneuralmicrosystemsapplicationsInvivoapplicationsInvitroapplicationsMicroelectronictechnology
forMicroelectrodesBondingpadsSisubstrateExposedtipsLeadviaChannelsElectrodeSiliconprobeSiliconchipMiniatureinsulatingchamberContactmetalfilmHoleSiO2insulatedAuprobesSiliconprobeExposedelectrodesInsulatedleadvias(b)(d)(a)(c)Differenttypesofmicroelectrodesfabricatedusingmicrofabrication/MEMStechnologyBeam-leadmultipleelectrode.MultielectrodesiliconprobeMultiple-chamberelectrodePeripheral-nerveelectrodeMichiganProbesforNeuralRecordingsNeuralRecordingMicroelectrodesReference:acreo.se/acreo-rd/IMAGES/PUBLICATIONS/PROCEEDINGS/ABSTRACT-KINDLUNDH.PDFInvivoneuralmicrosystems:3examplesUniversityofMichiganSmartcomb-shapemicroelectrodearraysforbrainstimulationandrecordingUniversityofIllinoisatUrbana-ChampaignHigh-densitycomb-shapemetalmicroelectrodearraysforrecordingFraunhoferInstituteofBiomedical(FIBE)EngineeringRetina
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 网络安全投标售后保障
- 玩具店内部装修工装施工合同
- 矿石材料标签规范
- 车站监控系统施工合同
- 农业用肥料标签管理办法
- 铝厂混凝土施工合同
- 咨询公司财务规划策略
- 环保技术开发招标办法
- 酒类批发市场卫生条例
- 温泉公园施工合同
- 部编人教版《道德与法治》四年级上册第11课《变废为宝有妙招》说课课件(第1课时)
- 年产40万吨灰底涂布白板纸造纸车间备料及涂布工段初步设计
- “全民健身”体育与健康知识考试题库(供参考)
- 三年级语文学情全面分析
- 评审专家个人评审意见表
- 【语文】江苏省苏州市实验小学小学三年级上册期末试题(含答案)
- 过敏性休克抢救步骤流程图
- MOOC创新创业与管理基础(东南大学)
- 医疗器械经营质量管理制度汇编
- 中国八大植被区域划分
- 厂内机动叉车日常检查记录表
评论
0/150
提交评论