




版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
PAGEPAGE3PAGE1给排水GAC18-002首钢空港项目I44/03地块
主要规范、标准《建筑给水排水设计标准》GB50015-2019《建筑设计防火规范》GB50016-2014(2018年版)《民用建筑节水设计标准》GB5055-2010《消防给水及消火栓系统技术规范》GB50974-2014《自动喷水灭火系统设计规范》GB50084-2017《城镇给水排水技术规范》GB50788-2014《建筑灭火器配置设计规范》GB50140-2005《建筑机电工程抗震设计规范》GB50981-2014《上海住宅设计标准》DGJ08-20-2013(2016年局部修订)《汽车库、修车库、停车场设计防火规范》GB50067-2014《民用建筑水灭火系统设计规程》DGJ08-94-2007用水量计算1.消防用水量建筑类别室外消火栓系统用水量(L/s)室内消火栓系统用水量(L/s)消火栓系统作用时间(h)室外消火栓系统用水量(m3)室内消火栓系统用水量(m3)喷淋系统用水量(L/s)喷淋系统作用时间(h)喷淋系统用水量(m3)高层住宅1510210872000配套用房15152108108351126幼儿园25152180108351126地下车库20102144723511262.生活用水量:公厕内主要用水器具为大(小)便器、洗手盆,此外地面冲洗也需消耗一定水量。根据《给水排水工程快速设计手册—3建筑给排水工程》(中国建筑工业出版社1998年出版,刘文镔主编)中的数据,估算本项目拟建公厕用水情况,结果见下表。拟建公厕用水估算结果用水器具用水指标数量用水量(m3/d)大便器(冲洗)80L/h/蹲位12个7.68小便器(冲洗)70L/h/蹲位4个2.24洗手盆(洗涤)20L/h/个5个0.8拖把池(冲洗)30L/h/个1个0.24地面(冲洗)6L/m2/天60m20.36合计11.32m3/d地库给水泵房内设无负压给水设备:供水低区采用市政压强供给,市政供水服务标高390.00,中区无负压生活给水加压设备(两用一备):WII(I)-T2-CH3-WDL32-3-2,系统设计参数:Q=49.14m3/h,H=31.52m,N=5.5kW,高区无负压生活给水加压设备(两用一备):WII(I)-T2-CH3-WDL32-4,系统设计参数:Q=43.33m3/h,H=55.76m,N=7.5kW;满足住宅车库给水使用要求。生活给水系统给水系统简述:本项目由西侧市政给水管引两路DN200给水管至本地块内并成环(引入管处市政管网为环状管网,引入管间设置阀门,市政给水服务标高390.00),供生活给水,消防给水采用前期8号地块的消防泵供给。住宅生活给水系统采用重力给水及无负压变频给水组合供水。住宅部分供水低区采用市政压强供给,其余楼层采用无负压给水泵分区给水,高位消防水箱及消防增压稳压设备设置于3#楼单体屋面。配套用房采用市政给水,变频泵设置于地下车库生活泵房内,消防泵及喷淋泵设置于前期地下车库消防泵房之内。住宅低区市政直供:低区住户一层6户,共有156户。每户人数估算3.2人,用水标准200,设计秒流量qg=0.2·U·Ng=7.56L/S=27.21m3/h供水干管管径DN80,流速1.45m/S服务标高390.00(在390.00处压力约等于0.15MPa)采用DN80钢塑管,住宅中区:中区住户一层6户,共有420户。每户人数估算3.2人,用水标准200,设计秒流量qg=0.2·U·Ng=13.65L/S=49.14m3/h供水干管管径DN100,流速1.66m/S,水头损失2.1+4.4+0.6,立管水损0.5m,总沿程损失7.6m,局部水损1.52倒流防止器水损3m;供水高度相对地面标高26.4m,富裕水头15m,水泵房地面标高378.9m,3#楼负一层地面标高380.2,地面1.1m高差,水泵基础200,基础到管心距离600,一共800,车库层高3.8m,无负压利用市政压力考虑26.1m;水泵杨程7.6+1.52+3+26.4+15+1.1+3.8-0.8-26.1=31.52m;供水泵组:中区无负压生活给水加压设备(两用一备):WII(I)-T2-CH3-WDL32-3-2,系统设计参数:Q=49.14m3/h,H=31.52m,N=5.5kW住宅高区:高区住户一层6户,共有342户。每户人数估算3.2人,用水标准200,设计秒流量qg=0.2·U·Ng=12.04L/S=43.33m3/h供水干管管径DN100,流速1.46m/s,水头损失1.7+4.3+0.7+1.1m,立管水损1.1m,总沿程损失7.8m,局部水损1.56,倒流防止器水损3m;供水高度相对地面标高50.4m,富裕水头15m,水泵房地面标高378.9m,3#楼负一层地面标高380.2,地面1.1m高差,水泵基础200,基础到管心距离600,一共800,车库层高3.8m,无负压利用市政压力考虑26.1m;水泵杨程7.8+1.56+3+50.4+15+1.1+3.8-0.8-26.1=55.76m;供水泵组:高区无负压生活给水加压设备(两用一备):WII(I)-T2-CH3-WDL32-4,系统设计参数:Q=43.33m3/h,H=55.76m,N=7.5kW四.消火栓泵:本地块消火栓泵流量10L/s;最不利点位于3#楼右单元顶层消火栓;系统水压计算:消火栓干管DN100,流量10L/s,管道流速v=1.217m/s,单位水损i=0.014;消火栓干管长度500m,局部阻力系数0.2,安全系数0.2;水头损失500*0.014*1.2*1.2=10.08m;单体引入管DN100,流量10L/s,管道流速v=1.217m/s,单位水损i=0.014;消火栓最不利干管长度375m,局部阻力系数0.2,安全系数0.2;水头损失375*0.014*1.2*1.2=7.6m;最不利点(3#楼顶层实验消火栓)所需供水高度54.5m;消火栓栓口所需压力0.35MPa;泵组出水管倒流防止器水头水损4m;消防泵所需扬程:54.5+7.6+35+4+21=123.1m;消防泵参数:Q=15L/s,H=1.3MPa,N=37KW,一用一备;五.喷淋泵计算:计算原理参照《自动喷水灭火系统设计规范GB50084-2001》(2005年版)基本计算公式:1、喷头流量:式中:q--喷头处节点流量,L/minP--喷头处水压(喷头工作压力)MPaK--喷头流量系数2、流速V:式中:Q--管段流量L/sDj--管道的计算内径(m)3、水力坡降:式中:i--每米管道的水头损失(mH20/m)V--管道内水的平均流速(m/s)dj--管道的计算内径(m),取值应按管道的内径减1mm确定4、沿程水头损失:式中:L--管段长度m5、局部损失(采用当量长度法):(当量)式中:L(当量)--管段当量长度,单位m(《自动喷水灭火系统设计规范》附录C)6、总损失:7、终点压力:管段名称起点压力mH2O管道流量L/s管长m当量长度管径mmK水力坡降mH2O/m流速m/s损失mH2O终点压力mH2O1-215.001.630.300.6025800.8922.780.8015.802-315.801.632.451.0025800.8922.783.0818.883-418.883.450.554.6080800.0130.670.0718.9426-416.171.691.901.0025800.9612.892.7918.964-518.945.141.274.6080800.0281.000.1719.115-619.115.140.830.7580800.0281.000.0419.1527-616.411.701.901.0025800.9752.912.8319.2328-617.581.760.551.0025801.0453.011.6219.206-719.158.601.603.6050800.7643.943.9723.1229-3017.811.772.450.9025801.0593.033.5521.3630-721.363.710.553.0040800.5182.771.8423.2031-722.501.991.901.8040800.1491.490.5523.057-823.1214.310.464.3065800.5433.932.5825.7132-3321.281.942.451.2040800.1411.450.5121.8033-3421.803.900.552.7040800.5712.911.8623.6635-3423.202.021.901.5040800.1541.510.5223.7334-823.665.921.843.8550800.3622.712.0625.718-925.7120.235.754.6080800.4363.944.5130.229-1030.2220.231.770.0080800.4363.940.7730.9910-1130.9920.236.913.7080800.4363.944.6235.6136-3732.672.403.201.8040800.2161.791.0833.7537-3833.754.840.874.6080800.0250.940.1433.8938-3933.894.840.602.7080800.0250.940.0833.9743-4431.882.372.551.5040800.2111.770.8632.7344-3932.734.771.983.6050800.2352.191.3134.0439-4033.979.612.844.9065800.2452.641.9035.8745-4632.122.382.211.5040800.2131.780.7932.9148-4934.082.452.211.5050800.0621.120.2334.3150-5132.952.413.201.5040800.2181.801.0333.9851-4133.984.861.984.1050800.2442.231.4835.4652-5334.222.462.201.8040800.2271.830.9135.1353-4135.134.951.424.9065800.0651.360.4135.5454-4632.462.390.541.5040800.2151.790.4432.9046-4732.914.773.003.6050800.2352.191.5534.4655-4733.522.432.211.8040800.2221.820.8934.4156-4733.982.450.541.8040800.2251.830.5334.5147-4034.469.650.794.9065800.2472.651.4035.8757-4933.872.440.541.5040800.2241.820.4634.3249-4034.314.902.214.1050800.2472.241.5635.8740-4135.8724.164.619.20150800.0171.210.2436.1041-4235.4633.972.409.20150800.0341.700.3935.8542-1135.8533.971.770.00150800.0341.700.0635.9111-1235.6154.200.439.20150800.0862.720.8336.4412-1336.4454.2014.460.00150800.0862.721.2537.6813-1437.6854.200.429.20150800.0862.720.8338.5114-1538.5154.202.600.00150800.0862.720.2238.7415-1638.7454.202.800.00150800.0862.720.2438.9816-1738.9854.202.800.00150800.0862.720.2439.2217-1839.2254.202.800.00150800.0862.720.2439.4618-1939.4654.202.800.00150800.0862.720.2439.7019-2039.7054.203.200.00150800.0862.720.2839.9820-2139.9854.200.730.00150800.0862.720.0640.0421-2240.0454.2018.269.20150800.0862.722.3742.4122-2342.4154.206.390.00150800.0862.720.5542.9623-2442.9654.2017.939.20150800.0862.722.3445.2924-2545.2954.209.230.00150800.0862.720.8046.09计算结果:所选作用面积:159.4平方米总流量:54.20L/s平均喷水强度:20.40L/min.平方米入口压力:46.09米水柱喷淋干管管径DN150,管道流速v=1.74m/s,单位水损i=0.017;最不利干管长度285m;水头损失285*0.017*1.2*1.2(安全系数)=6.97m;最不利点所需供水高度21.00m;报警阀组等局部水头损失6m;泵组出水管倒流防止器水头水损4m;喷淋泵所需扬程:6.97+21+46.90+6+4=84.87m;喷淋泵参数:Q=35L/s,H=110m,P=90Kw,一用一备;六、污水排水系统本工程排水量按用水量90
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 游乐设施施工材料性能与应用考核试卷
- 组织领导力与决策过程优化考核试卷
- 互联网平台人工智能技术应用考核试卷
- 2025标准合同签订流程范本
- 2025商品房买卖合同纠纷与特征范本
- 2025年标准个人门面出租合同模板
- 第03讲 平方差与完全平方公式(原卷板)
- 二零二五违纪学生协议合同书范例
- 洗碗工的劳动合同书范例二零二五年
- 二零二五年薪制劳动合同范文
- 老年患者围手术期多模式镇痛低阿片方案中国专家共识(2021全文版)
- 2024年基金应知应会考试试题
- 2024-2025学年高二上学期期中家长会-家校同频共话成长 课件
- 混合痔的中医护理方案
- 托幼机构卫生评价报告
- 国开(内蒙古)2024年《经济学与生活》形考1-3答案
- 新疆维吾尔自治区2025届高考压轴卷生物试卷含解析
- DL∕T 592-2010 火力发电厂锅炉给水泵的检测与控制技术条件
- 2024届浙江省杭州市英特外国语学校八年级英语第二学期期末复习检测试题含答案
- 意识与计算的理论模型
- 工程伦理案例与分析
评论
0/150
提交评论