




版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
《暖通空调》课程设计说明书学院:专业:班级:学生姓名:指导教师:目录1工程概述-------------------------------------------------------------------------------12设计依据-------------------------------------------------------------------------------12.1设计任务书------------------------------------------------------------------------12.2设计规范及标准------------------------------------------------------------------13设计任务--------------------------------------------------------------------------------14设计参数--------------------------------------------------------------------------------14.1建筑平面附图-----------------------------------------------------------------------4.2空调设计室外空气计算参数-----------------------------------------------------24.3室内空气设计参数及有关--------------------------------------------------------24.4冷热源和动力供应-----------------------------------------------------------------24.5其他-----------------------------------------------------------------------------------25空调负荷计算--------------------------------------------------------------------------35.1空调冷负荷计算方法--------------------------------------------------------------35.2相关参数的选取--------------------------------------------------------------------35.3冷负荷的计算-----------------------------------------------------------------------45.3.1外墙和屋面瞬时传热引起的冷负荷------------------------------------------45.3.2内墙、地面引起的冷负荷------------------------------------------------------85.3.3外玻璃窗瞬时传热引起的冷负荷---------------------------------------------95.3.4透过玻璃窗日射的热引起的冷负荷------------------------------------------95.3.5人体散热形成的冷负荷--------------------------------------------------------125.3.6照明、设备散热形成的冷负荷-----------------------------------------------155.4湿负荷计算-------------------------------------------------------------------------155.5新风古河计算----------------------------------------------------------------------155.6夏季空调计算表及汇总----------------------------------------------------------166风机盘管加新风独立系统设计计算----------------------------------------------166.1夏季送风状态点和送风量--------------------------------------------------------166.2风机盘管的选择--------------------------------------------------------------------176.3新风机组的选型--------------------------------------------------------------------186.4风机盘管回风口栅格尺寸计算--------------------------------------------------196.5风管尺寸计算选型-----------------------------------------------------------------196.6冷冻水水管水力计算--------------------------------------------------------------206.6.1水系统水力计算基本公式------------------------------------------------------206.6.2管径的确定------------------------------------------------------------------------206.6.3冷冻水水力计算表---------------------------------------------------------------216.6.4系统水环路相关选择------------------------------------------------------------216.7冷凝水管路设计--------------------------------------------------------------------227散热器采暖系统(另外单独设计)-----------------------------------------------227.1冬季热负荷的计算-----------------------------------------------------------------227.2热负荷计算表-----------------------------------------------------------------------237.3散热器选型--------------------------------------------------------------------------307.4采暖系统水力计算-----------------------------------------------------------------301工程概述设计题目:九江市某别墅住宅的供热、空调工程设计本工程为江西九江某一别墅,砖混结构共两层,第一层层高为3m,二层3m,顶棚层高2.7m。总建筑面积约200m2(2×100m2)。底层为车库、工人房、餐厅、厨房、客厅、盥洗室、浴室。二层为西卧室、东卧室、北浴室、东浴室、主卧室、起居室。已给出建筑平面图,立面图和各个房间的功能,要求设计该别墅夏季和冬季风机盘管+独立新风系统和单独设计冬季散热器采暖系统。2设计依据2.1设计任务书《暖通空调》课程设计任务书2.2设计规范及标准(1)中华人民共和国国家标准(BJ50019-2003版)。采暖通风与空气调节设计规范〔S〕。北京:中国规划出版社,2003.(2)建筑制图标准汇编〔S〕。北京:中国计划出版社,1996.(3)陆耀庆。实用供热空调设计手册〔M〕。北京:中国建筑工业出版社。(4)机电部第十设计研究院。空气调节设计手册〔M〕。北京:中国建筑工业出版社,1986.3设计任务(一)供暖方案的选择和确定。(二)空调方案的选择和确定。(三)计算任务。1.围护结构的冷负荷、耗热量计算;2.室内设备、人员散热、散湿负荷计算;3.散热器及空调末端设备选择计算;4.供暖、空调系统水力计算。(四)绘图部分1.绘制采暖系统的平面图及系统图;2.绘制空调系统的平面图及系统图;3.必要的剖面图。(五)提交设计工作量图纸量:不少于A2图纸3张;设计计算书1份。4设计参数4.1建筑平面附图见设计任务书附图及表。4.2空调设计室外空气计算参数:⑴.地理位置:北纬—29°44’;经度:东经116°00’;海拨:32.2m;⑵.大气压力:冬季—102190Pa;夏季—100090Pa;⑶.室外空气参数,见下表室外空气参数表空气参数数值空气参数数值1夏季空调室外计计算干球温温度tw36.4℃夏季空调室外计计算湿球温温度ts28.3℃2夏季空调室外日日平均温度度twp32.4℃夏季通风室外计计算温度33℃3冬季空调室外计计算干球温温度0℃冬季通风室外计计算温度4℃4冬季室外计算相相对湿度75%夏季室外计算相相对湿度60%5夏季室外平均风风速2.4m/s冬季室外平均风风速3.0m/s6全年主导风向NE年平均温度17.6℃4.3室内空气设计参数及有关指标见表室内设计参数表夏季冬季新风量(m3/人.h)温度℃湿度%风速温度℃湿度%风速工人房26600.2510600.2030车库26600.255600.2030盥洗室26600.2518600.2030餐厅26600.2516600.2030厨房26600.2518600.2030一楼浴室26600.2525600.2030客厅26600.2516600.2030西卧室26600.2518600.2030东卧室26600.2518600.2030起居室26600.2518600.2030主卧室26600.2520600.2030北浴室26600.2525600.2030东浴室26600.2525600.20304.4冷热源和动力供应:(1)冷、热水管网在别墅西北,由西向东;(2)热水管网具有95/70℃、60/50℃(二者只能用一种)热水;(3)夏季冷水管网具有7/12℃冷水供应;(4)小区有足够的动力电源及天然气源保证供应。4.5其他(1)住宅平时6居住;(2)照明按一般住宅选取。照明负荷为20W/(m2*h)。其他设备负荷也为20W/(m2*h);(2)夏季室内空气压力稍高于室外大气压。5空调负荷计算5.1空调冷负荷计算方法在空调工程设计中,存在两中冷负荷计算的计算方法:一为谐波反应法(负荷温差法),一为冷负荷系数法。谐波反应法(负荷温差法)计算的冷负荷的形成包括两个过程:一是由于外扰(室外综合温度)形成室内得热量的过程(既内扰量)。此一过程考虑外扰的周期性以及围护结构对外扰量的衰减和延迟性。二是内扰量形成冷负荷的过程。此一过程是将该热扰量分成对流和辐射两种成分。前者是瞬时冷负荷的一部分,后者则要考虑房间总体蓄热作用后才化为瞬时冷负荷。两部分叠加即得各计算时刻的冷负荷。冷负荷系数法是在传递函数的基础上为便于在工程中进行手算而建立起来的一种简化计算法。通过冷负荷温度与冷负荷系数直接从各种扰量值求得各分项逐时冷负荷。本设计采用冷负荷系数法冷负荷的计算。5.2相关参数的选取围护结构参数见下围护结构参数表结构类型具体结构及参数数传热系数Kj/(m2**℃)外墙外水泥砂浆抹灰灰加浅色喷喷浆:20mmm砖墙:240mmm加气混凝土保温温层:1220mmm内粉刷加油漆::20mmm0.88内墙240mm普通通砖墙,两两侧有20mm水泥砂浆浆抹面,涂涂白色外墙墙涂料1屋面砖红色粘土装饰饰瓦屋面,瓦瓦材下面设设100mmm保温层二层顶棚水泥砂浆找平层层:20mmm泡沫混泥土保温温层:1000mm现浇钢筋混泥土土楼板:70mmm麻刀灰抹面:220mm0.97外门单层实木4.65外门双层实木2.33内门单层实木2.91一层顶棚1:2.5水泥砂浆浆抹面:20mmm现浇钢筋混泥土土楼板:70mmm麻刀灰抹面:220mm窗铝合金门窗,双双层玻璃3.01其它的冷负荷相关参数见表(四)其它冷负荷相关参数表房间名称人员照明设备散热W/m2劳动强度群集系数类型功率W/m2办公室轻0.93暗装荧光灯,灯灯罩有孔2020注:(1)网网络机房、数数据处理中中心,设备备按实际发发热量估算算。(2)室内保持正正压,不考考虑空气渗渗透引起的的冷负荷。(3)本设计计由于内部部房间的温温差较小,不不考虑内围围护结构的的传热。5.3冷负荷荷的计算5.3.1、外外墙和屋面面瞬时传热热引起的冷冷负荷Qc(τ)=AKK[(tcc+td)kαkρ-tR](5-11)式中:QQc(τ)---------外墙和屋屋面瞬变传传热引起的的逐时冷负负荷,W;A---------外墙和屋屋面的面积积,m2;K---------外墙和屋屋面的传热热系数,W/(mm2·℃);tR---------室内计算算温度,℃;tc---------外墙和屋屋面冷负荷荷计算温度度的逐时值值,℃;由《暖通空调》附附录2-4和附录2-5查取;td---------地点修正正值,由《暖暖通空调》附附录2-6查取;kα---------吸收系数数修正值;;kρ---------外表面换换热系数修修正值;西外墙时间0:001:002:003:004:005:006:007:00tc(τ)38.538.939.139.239.138.938.638.2Δtd2Kα1Kρ0.94tc(τ)'38.0738.4538.6338.7338.6338.4538.1637.79tR26Δt12.0712.4512.6312.7312.6312.4512.1611.79K0.88Qc(τ)单位面积10.6210.9511.1211.2011.1210.9510.7010.37时间8:009:0010:0011:0012:0013:0014:0015:00tc(τ)37.837.336.836.335.935.535.234.9Δtd2Kα1Kρ0.94tc(τ)'37.4136.9436.4736.0035.6335.2534.9734.69tR26Δt11.4110.9410.4710.009.639.258.978.69K0.88Qc(τ)单位面积10.049.639.228.808.478.147.897.64时间16:0017:0018:0019:0020:0021:0022:0023:00tc(τ)34.834.834.935.535.836.537.338Δtd2Kα1Kρ0.94tc(τ)'34.5934.5934.6935.2535.5336.1936.9437.60tR26Δt8.598.598.699.259.5310.1910.9411.60K0.88Qc(τ)单位面积7.567.567.648.148.398.979.6310.21东外墙时间0:001:002:003:004:005:006:007:00tc(τ)38.538.438.23837.637.336.936.4Δtd2Kα1Kρ0.94tc(τ)'38.0737.9837.7937.6037.2236.9436.5736.10tR26Δt12.0711.9811.7911.6011.2210.9410.5710.10K0.88Qc(τ)单位面积10.6210.5410.3710.219.889.639.308.88时间8:009:0010:0011:0012:0013:0014:0015:00tc(τ)3635.538.2353535.235.636.1Δtd2Kα1Kρ0.94tc(τ)'35.7235.2537.7934.7834.7834.9735.3435.81tR26Δt9.729.2511.798.788.788.979.349.81K0.88Qc(τ)单位面积8.558.1410.377.737.737.898.228.64时间16:0017:0018:0019:0020:0021:0022:0023:00tc(τ)36.637.137.537.938.238.438.538.6Δtd2Kα1Kρ0.94tc(τ)'36.2836.7537.1337.5137.7937.9838.0738.16tR26Δt10.2810.7511.1311.5111.7911.9812.0712.16K0.88Qc(τ)单位面积9.059.469.7910.1310.3710.5410.6210.70北外墙时间0:001:002:003:004:005:006:007:00tc(τ)33.133.233.233.233.13332.832.6Δtd2.8Kα1Kρ0.94tc(τ)'33.7533.8433.8433.8433.7533.6533.4633.28tR26Δt7.757.847.847.847.757.657.467.28K0.88Qc(τ)单位面积6.826.906.906.906.826.736.576.40时间8:009:0010:0011:0012:0013:0014:0015:00tc(τ)32.332.131.831.631.431.331.231.2Δtd2.8Kα1Kρ0.94tc(τ)'32.9932.8132.5232.3432.1532.0531.9631.96tR26Δt6.996.816.526.346.156.055.965.96K0.88Qc(τ)单位面积6.155.995.745.585.415.335.245.24时间16:0017:0018:0019:0020:0021:0022:0023:00tc(τ)31.331.431.631.832.132.432.632.9Δtd2.8Kα1Kρ0.94tc(τ)'32.0532.1532.3432.5232.8133.0933.2833.56tR26Δt6.056.156.346.526.817.097.287.56K0.88Qc(τ)单位面积5.335.415.585.745.996.246.406.65南外墙时间0:001:002:003:004:005:006:007:00tc(τ)36.136.236.236.135.935.635.335Δtd0.4Kα1Kρ0.94tc(τ)'34.3134.4034.4034.3134.1233.8433.5633.28tR26Δt8.318.408.408.318.127.847.567.28K0.88Qc(τ)单位面积7.317.407.407.317.156.906.656.40时间8:009:0010:0011:0012:0013:0014:0015:00tc(τ)34.634.233.933.533.232.932.832.9Δtd0.4Kα1Kρ0.94tc(τ)'32.9032.5232.2431.8731.5831.3031.2131.30tR26Δt6.906.526.245.875.585.305.215.30K0.88Qc(τ)单位面积6.075.745.495.164.914.674.584.67时间16:0017:0018:0019:0020:0021:0022:0023:00tc(τ)33.133.433.934.434.935.335.736Δtd0.4Kα1Kρ0.94tc(τ)'31.4931.7732.2432.3433.1833.5633.9334.22tR26Δt5.495.776.246.347.187.567.938.22K0.88Qc(τ)单位面积4.835.085.495.586.326.656.987.23屋面按稳态传热热计算屋顶冷负荷(按按稳定传热热计算)::Qc(τ)=KiAi(to,mm+Δta-tR)Ki1.15Ai116.46to,m32.4Δta1.7tR26Qc(τ)单位面积9.32门也也以稳态传传热计算南外门单层层实木Ki4.65Ai3.6to,m32.4Δta7tR26Qc(τ)224.3166北外门单层层实木Ki4.65Ai2.52to,m32.4Δta7tR26Qc(τ)157.0211内门单层实木木Ki2.91Ai1to,m32.4Δta7tR26Qc(τ)单位面积38.99M-2Qcc(τ)73.70M-3Qcc(τ)65.51M-4Qcc(τ)59.275.3.2、内内墙、地面面引起的冷冷负荷Qcc(τ)=AiKi(to.m+Δtα-tR)(5--2)式中中:ki--------内围护结结构传热系系数,W/(mm2·℃);地面:0.47,W/(mm2·℃);AAi---------内围护结结构的面积积,m2;to.m---------夏季空调调室外计算算日平均温温度,℃;Δtα--------附加温升升。注意:这里简化化成稳态传传热的计算算内墙3型(单位面面积冷负荷荷:Qc(τ)=KiAi(to,mm+Δta-ttR))Ki1.97Ai1to,m32.4Δta7tR26Qc(τ)单位面积26.405.3.3、外外玻璃窗瞬瞬时传热引引起的冷负负荷Qc(τ)=cwKwAw(tc(τ)+td-tR)(55-3)式中:Qc(τ)--------外玻璃窗窗瞬变传热热引起的冷冷负荷,W;Kw---------外玻璃窗窗传热系数数,W/(mm2·℃),Kw=55.9WW/(m22·℃)Aw---------窗口面积积,m2;tc(ττ)---------外玻璃窗窗的冷负荷荷温度的逐逐时值,℃,由《暖通空调》附附录2-10查得;cw---------玻璃窗传传热系数的的修正值;;由《暖通空调》附附录2-9查得,单单层金属窗窗框cw=1.00td---------地点修正正值;外窗瞬时传热冷冷负荷,αi=8..7w/((m2*kk),α0=188.62ww/(m22*k)Kw==3.011w/(mm2*k)修正系数Cw==1.2查书.重庆Δtd=33时间0:001:002:003:004:005:006:007:00tc(τ)27.226.726.225.825.525.325.426Δtd3tR26Δt4.203.703.202.802.502.302.403.00Kw3.612Qc(τ)单位面积15.1713.3611.5610.119.038.318.6710.845.3.4、透透过玻璃窗窗的日射得得热引起的的冷负荷Qc(τ)=CαAwCsCiDjmaxxCLQ((5-4))式中:Cα--------有效面积积系数,由由《暖通空空调》附录录2-15查得;Aw--------窗口面积积,m2;Cs--------窗玻璃的的遮阳系数数,由《暖暖通空调》附附录2-13查得;Ci--------窗内遮阳阳设施的遮遮阳系数,由由《暖通空空调》附录录2-14查得;Djmax---------日射得热热因数,由由《暖通空空调》附录录2-12查得30纬度带的日日射得热因因数;CLQ--------窗玻璃冷冷负荷系数数,无因次次透过玻璃日射得得热引起的的冷负荷有效面积积系数Ca=00.75遮档系数Cs==0.866遮阳系数Cii=0.55(白布帘)综合遮阳阳系数Cc,ss=0.886*0..5=0..43公式Qc(τ)=Ca**Aw*CCs*Cii*Djmmax*CClQ西窗时间0:001:002:003:004:005:006:007:00ClQ0.080.070.070.060.060.060.080.11Djmax539Cc,s0.43Qc(τ)单位有效面积18.5416.2216.2213.9113.9113.9118.5425.49东窗时间0:001:002:003:004:005:006:007:00ClQ0.060.050.050.050.040.040.470.68Djmax539Cc,s0.43Qc(τ)单位有效面积13.9111.5911.5911.599.279.27108.93157.60北窗时间0:001:002:003:004:005:006:007:00ClQ0.120.110.110.10.090.090.590.54Djmax115Cc,s0.43Qc(τ)单位有效面积5.935.445.444.954.454.4529.1826.70南窗时间0:001:002:003:004:005:006:007:00ClQ0.070.070.060.060.060.050.110.18Djmax174Cc,s0.43Qc(τ)单位有效面积5.245.244.494.494.493.748.2313.47西窗时间8:009:0010:0011:0012:0013:0014:0015:00ClQ0.140.170.180.190.20.340.560.72Djmax539Cc,s0.43Qc(τ)单位有效面积32.4539.4041.7244.0446.3578.80129.79166.87东窗时间8:009:0010:0011:0012:0013:0014:0015:00ClQ0.820.790.590.380.240.240.230.21Djmax539Cc,s0.43Qc(τ)单位有效面积190.05183.10136.7488.0755.6255.6253.3148.67北窗时间8:009:0010:0011:0012:0013:0014:0015:00ClQ0.540.650.750.810.830.830.790.71Djmax115Cc,s0.43Qc(τ)单位有效面积26.7032.1437.0940.0541.0441.0439.0735.11南窗时间8:009:0010:0011:0012:0013:0014:0015:00ClQ0.260.40.580.720.840.80.620.45Djmax174Cc,s0.43Qc(τ)单位有效面积19.4529.9343.4053.8762.8559.8646.3933.67西窗时间16:0017:0018:0019:0020:0021:0022:0023:00ClQ0.830.770.530.110.10.090.090.08Djmax539Cc,s0.43Qc(τ)单位有效面积192.37178.46122.8425.4923.1820.8620.8618.54东窗时间16:0017:0018:0019:0020:0021:0022:0023:00ClQ0.180.150.110.080.070.070.060.06Djmax539Cc,s0.43Qc(τ)单位有效面积41.7234.7725.4918.5416.2216.2213.9113.91北窗时间16:0017:0018:0019:0020:0021:0022:0023:00ClQ0.60.610.680.170.160.150.140.13Djmax115Cc,s0.43Qc(τ)单位有效面积29.6730.1633.638.417.917.426.926.43南窗时间16:0017:0018:0019:0020:0021:0022:0023:00ClQ0.320.240.160.10.090.090.080.08Djmax174Cc,s0.43Qc(τ)单位有效面积积23.9417.9611.977.486.736.735.995.995.3.5、人人体散热形形成的冷负负荷5.3.5.11、人体显显热散热形形成的冷负负荷Qc(τ)=qqsnφCLQ(5-6--1)式中:qs---------不同室温温和劳动性性质成年男男子显热散散热量;n--------室内全部部人数;φ--------群集系数数,由《暖暖通空调》表2-12查得;CLQ--------人体显热热散热冷负负荷系数,由由《暖通空空调》附录录2-233查得;5.3.5.22、人体潜潜热散热引引起的冷负负荷QQc(τ)=qqlnφ(5-6--2)式中:ql---------不同室温温和劳动性性质成年男男子潜热散散热量,W;n,φ--------同式5-6--1;人员散热引起的的冷负荷按宾馆标标准,属极极轻劳动,tR=226℃,一个成年男人的的散热冷负负荷Q=Qcc(τ)+Qcc=qs**n*ψ*CLQQ+q1**n*ψ主卧室主卧室人停留118个小时(16:000--110:000)2个人时间0:001:002:003:004:005:006:007:00ClQ0.920.930.940.940.950.960.960.97qs60.5n2ψ0.93Qc(τ)103.53104.65105.78105.78106.90108.03108.03109.15q173.30Qc136.34136.34136.34136.34136.34136.34136.34136.34Q239.87240.99242.12242.12243.24244.37244.37245.49时间8:009:0010:0011:0012:0013:0014:0015:00ClQ0.970.970.50.40.330.280.240.21qs60.5n2ψ0.93Qc(τ)109.15109.1556.2745.0137.1331.5127.0123.63q173.30Qc136.34136.3136.34136.34136.34136.3136.34136.3Q245.49245.5192.60181.35173.47167.9163.35160.0时间16:0017:0018:0019:0020:0021:0022:0023:00ClQ0.660.740.790.820.850.870.890.9qs60.5n2ψ0.93Qc(τ)74.2783.2788.9092.2795.6597.90100.15101.28q173.30Qc136.34136.3136.34136.34136.34136.3136.34136.3Q210.61219.6225.24228.61231.99234.2236.49237.6卧室人停留18个小小时(16:000--110:000)1个人时间0:001:002:003:004:005:006:007:00Q119.93120.50121.06121.06121.62122.2122.18122.75时间8:009:0010:0011:0012:0013:0014:0015:00Q122.75122.7596.3090.6886.7483.9281.6779.98时间16:0017:0018:0019:0020:0021:0022:0023:00Q105.30109.81112.62114.31115.99117.12118.25118.8客厅人活动14个小小时(10:000--00:00)3个人时间0:00:0001:002:00:0003:004:005:006:007:00ClQ0.940.470.380.310.260.230.20.17qs60.5n3ψ0.95Qc(τ)162.0881.0465.5253.4544.8339.6634.4929.31q173.30Qc208.91Q370.98289.94274.43262.36253.74248.56243.39238.22时间8:009:0010:0011:0012:0013:0014:0015:00ClQ0.150.130.110.580.660.720.770.8qs60.5n3ψ0.95Qc(τ)25.8622.4218.97100.01113.80124.15132.77137.94q173.30Qc208.91Q234.77231.32227.87308.91322.71333.05341.67346.85时间16:0017:0018:0019:0020:0021:0022:0023:00ClQ0.830.850.870.890.90.910.920.93qs60.5n3ψ0.95Qc(τ)143.11146.56150.01153.46155.18156.91158.63160.36q173.30Qc208.91Q352.02355.47358.91362.36364.09365.81367.54369.26工人房人活动8个小时时(0:000--8::00)2个人时间0:00:0001:002:00:0003:004:005:006:007:00ClQ0.040.510.610.670.720.760.80.82qs60.5n2ψ0.95Qc(τ)4.6058.6270.1277.0282.7687.3691.9694.26q173.30Qc139.27Q143.87197.89209.39216.29222.03226.63231.23233.53时间8:009:0010:0011:0012:0013:0014:0015:00ClQ0.840.380.30.250.210.180.150.13qs60.5n2ψ0.95Qc(τ)96.5643.6834.4928.7424.1420.6917.2414.94q173.30Qc139.27Q235.83182.95173.76168.01163.41159.96156.51154.21时间16:0017:0018:0019:0020:0021:0022:0023:00ClQ0.120.10.090.080.070.060.050.05qs60.5n2ψ0.95Qc(τ)13.7911.5010.359.208.056.905.755.75q173.30Qc139.27Q153.06150.77149.62148.47147.32146.17145.02145.025.3.6、照照明、设备备散热形成成的冷负荷荷全部统一计算::单位面积积照明、电电器设备负负荷为400W//(m^2)5.4、湿负负荷的计算算5.4.1、人人体散湿量量可按下式式计算:mw1=0.2778nψg×100-3g/s(5-7)式中:mw11---------人体散散湿量,g/s;;gg---------成年男子子的小时散散湿量,g/h;n--------室内全部部人数;ψ--------群集系数数5.5、新风负负荷计算5.5.1、夏夏季空调新新风冷负荷荷Qc.o=Mo(iw—in)(5-8)式中:Qc.oo--------夏季新风风冷负荷,KW;Mo--------新风量,kg/s;iw--------室外空气气的焓值,kJ/kkg;in--------室内空气气的焓值,kJ/kkg;5.6、夏季空空调计算表表(这里只只简单列出出0:000~11::00的计算结结果)及汇汇总各个房间的最大大负荷时负负荷(汇总总表)(冷冷负荷+新风负荷荷)散湿量(Mw==0.2778*n¢g单位10^((-3)gg/s)热湿比(﹩=QQ/M)<散湿量、热热湿比按房房间逐时最最大值计算算>一层按16:00:000计算按各房间逐时最最大计算散湿量热湿比工人房块2352235256.3641734餐厅7215987客厅块4939512784.5460648小计90829282253.63二层西北卧室1885188528.1866877东北卧室2010222428.1878927起居室1995199556.3635390主卧室3042312956.3655515楼梯692692走廊523523小计1014710448169.09总计1922919729422.71别墅负荷(冷负负荷+新风负荷荷)按最大值出现在在16:000:000时计算其最大值值为190112.833W按各房间逐时最最大负荷计计算其最大值值为197229.500w6风机盘管管加独立新新风系统设设计计算6.1、夏季季送风状态态点和送风风量考虑到卫生和能能效,选择择处理后的的新风和风风机盘管处处理过的空空气混合后后送入室内内的方案。采采用新风不不负担室内内负荷的方方式,即将将送入室内内的新风处处理到90%相对湿度度的室内等等焓点D(见焓湿图)。空调系系统送风状状态和送风风量的确定定可在i-d图上进行行,具体步步骤如下::⑴在i-d图上找出出室内状态态点N,室外状状态点W⑵根据计算出的室室内冷负荷荷Q和湿负荷W求出,取送送风温差为为8℃,送风状状态点通过过N点画出线与与φ=90℅线相交,即即得送风点点S⑶根据in等焓线线,由新风风处理后的的机器露点点相对湿度度定出D点⑷根据N、S两点确定房间总总风量⑸根据新风比确定定风机盘管管处理风量量及终状态态WNWN冷却干燥D冷却干燥F混合SNε6.2、风机盘盘管的选择择根据房间负荷,根根据Foridda(富力达)样本选用用型号,风风量有高,中中,低三档档,其它具具体参数请请参考样本本。表示为为:FOR-规格格WAHL//R两层各个房间的的送风状态态、送风量量、新风量量、新风比比、F状态点及及送风量和和风机盘管管选型列于于下表:室内设计状态点点t℃¢%ts℃dr(g/kgg)Ir(kj/kkg)2660%20.312.758.85送风状态点送风量G新风量GwEP风量(m^3//h)新风比Gw/GG(%)F点状态t℃¢%ts℃ds(g/kgg)IMs(kg/hh)m^3/hIf(kj/kkg)tf℃一层工人房1990%1812.52511187989609296.0749.5118.55餐厅18.790%17.612.3508066729058213.3948.8718.68客厅19.190%1812.651.3268922419021514.0249.5118.17二层西卧室19.190%1812.651.3989824307943.6449.5118.17东卧室19.190%1812.651.31167972309423.0949.5118.17起居室1990%1812.52511006839607797.1649.3518.55主卧室19.190%1812.651.3164113686013084.3949.5118.17风机盘管选型::夏季冬季风机盘管型号全热量W显热量W热量W一层工人房2587.4442448.1771069.5FOR-4000餐厅1982.2221982.2221720.1FOR-3000客厅5640.0885431.1881800.9两台FOR-4400二层西卧室2073.1222003.4991603.6FOR-3000东卧室2446.6552377.0221964.3FOR-4000起居室2194.1332194.1332194.133FOR-3000主卧室3441.8333302.5663302.566FOR-5000风机盘管相关参参数:风机盘管型号TH(W)SH(W)进水温度水量(L/s)水阻(kPa)进风温度冬季校核WBDB制热量W进水温度℃DB进风温度℃FOR-40003267261470.13818.72662756021FOR-30002765202770.16818.72648156021(两台)FORR-40003632274970.181518.726133016021FOR-30002765202770.16818.72648156021FOR-40003267261470.13818.72662756021FOR-30003238220270.261918.72651816021FOR-50004613340170.263118.726838560216.3、新风机机组的选型型总送风量为4550m3/h,新风冷冷负荷为4.477KW。选择Midea(美美的)新风风机组:KFR-75T1NN/XFSY其制冷量为9..1KW,制热量5.6KKW。其循环风量:11600m3/h其机外余压:660~1996Pa其室内机尺寸为为:860×6600×3806.4、风机盘盘管回风口口栅格尺寸寸计算:风机盘管回风口口栅格冷负荷(W)送风量G新风量Gw(mm^3/hh)回风量Gw(mm^3/hh)栅格面积(mmm^2)栅格尺寸(长X宽)Ms(kg//h)m^3/h一层工人房2587118798960929129028400X3500餐厅19828066729058280830400X2500客厅564026892241902151298763500X3000(两个)二层西卧室207398882430794110209400X3000东卧室2447116697230942130813400X3500起居室2194100683960779108127400X3000主卧室344116411368601308181613500X40006.5、风管尺尺寸计算选选型:风管管径D=GGW/(33600**v)((干管v=6~~8m/ss;支管v=3mm/s)新风量Gw/((m^3//h)面积/(mm^2))风管尺寸(高XX宽)总管42019444.444160x1600工人房605555.566120X1200餐厅908333.333120X1200客厅908333.333120X1200客厅+餐厅18012500.000120X1200层间立管18012500.000120X1200西卧+起居室906250.000120X1200西卧室302777.788120X1200东卧室302777.788120X1200起居室605555.566120X1200主卧室605555.566120X12006.6冷冻水水水管水力力计算方法法----假定流速速法以管道内水流速速作为控制制因素,先先按技术经经济要求选选定管道的的流速,再再根据管道道的流量确确定水管的的管径和查查设计手册册水力计算算表得到阻阻力,为选选择冷冻水水循环泵作作准备。6.6.1、水系统水水力计算基基本公式6.6.1.11、沿程阻阻力计算公公式Hf=R•LPaa(8-1)式中:Hf---------水管沿沿程阻力Pa;RR--------单单位长度沿沿程阻力,又又称比摩阻阻,PPa/m;LL--------管管长,m;6.6.1.22、局部阻阻力计算公公式Hd=Σξ•PdPa(8-2)式中:Hd--------水水管局部阻阻力系数,Pa;Σξ---------水管局部部阻力系数数;PPd--------水水管的动压压,Pa6.6.2、管管径的确定定按冷冻水供回水水7/12℃计算流量量,水泵压出出口流速取取2.4~~3.6mm/s,吸吸入口取1.2~~2.1mm/s,主主干管流速速取1.2~~4.5mm/s,一一般管道取取1.5~~3m/ss,闭式系系统选表面面当量绝对对粗糙度K=0.2mmm,确定主要要管段流量量、流速、管管径。相关关公式及依依据如下:冷量(W)=1.11*实际冷负负荷(W);1W=0.866kcall/h;流量(kg/s)==冷量(kcall/h)/36000(s//h)/55(℃);流速(m/s)=44*流量(kg//s)/00.0011/3.114/管径(mm)^2。注:1.风机盘管干管冷冷量按最大大负荷*1.1计算。2.风机盘管供供水环路管管径由大到到小渐缩,回回水环路由由小到大渐渐扩,流速速控制在2m/s以内内计算。6.6.3、冷冷冻水水管管水力计算算表:风机盘管水力计计算管段编号冷负荷¢/W流量qv/(m^^3/h))管段长度l/mm管径d/mm流速v/(m/s))比摩阻R/((Pa/mm)沿程损失Rl//Pa局部阻力系数动压△Pd/Pa局部阻力△Pjj/Pa管路损失△Pll/Pa123456789101112二层冷冻水水力力计算12036535020.50400.742231113.0272815926224474218.70150.3311710194.05421712363770913263.80250.6429811311.02072071338456369692.10200.7656011761.028828814645344259210.50150.841028107964.0356142612222∑(△Py+△Pj))1~99=44462.114Paa层间立管61020917568.50250.8550943225.036618306152一层冷冻水水力力计算725874452.00150.6459711942.020140315978762213113.00250.642918743.02026071481956409705.40200.7656230343.028986639001028204851.70150.6970311952.0239478167310'28204851.90150.6970313362.023947818141119823412.10150.493627592.0118237996其他管1220733561.50150.513935892.01292588481321943771.50150.544376562.01452909456.6.4、系系统水环路路相关选择择:(1)两管制两管制水系统是是采用同一一套供回水水管路,冬冬季供热水水、夏季供供冷水。两两管系统具具有管理方方便,一次次性投资较较小等优点点。本设计计对空调精精度要求不不是很高,故故采用两管管制。而三三管制是共共用一根回回水管,因因此冷热有有混合损失失,运行效效率不高,而而且系统水水力工况复复杂,难于于运行。四四管制初投投资较高且且多占空间间。(2)闭式1)水泵扬程仅需需克服循环环阻力,与与楼层数无无关仅取决决于管路长长度和阻力力。2)循环水不易受受污染,管管路腐蚀情情况比开式式系统好。3)不需要设回水水池,但要要设一个膨膨胀水箱。膨膨胀水箱尽尽量接至靠靠近水泵入入口的回水水干管。(3)同程系统6.7、冷凝凝水管路的的设计由于各种空调设设备如风机机盘管、新新风机组、空空调机组等等在运行的的过程中产产生的冷凝凝水,必须须及时予以以排走。排排放冷凝水水的管路设设计,应注注意以下各各要点:1.水流方向,水平平管道应保保持不小于于千分之一一的坡度;;且不允许许有积水部部位。2.为了防止冷凝水水管道表面面产生结露露,必须进进行防结露露验算。3.冷凝水立管的顶顶部应设计计通向大气气的透气管管。凝水管采用UPPVC管,冷凝水水管的公称称直径DN(mm),应根根据末端设设备的冷量量进行确定定。一般情情况下,每每1KW冷负荷每1h大约产生0.4kkg左右的冷冷凝水;在在潜热负荷荷较高的场场合,每1KW冷负荷每1h大约产生0.8kkg左右的冷冷凝水。根根据机组的的冷负荷Q(kW),按下下表(十六六)数据近近似选定冷冷凝水管的的公称直径径:凝水管管径选择择表冷量(W)≤7Kw7.1~17..6Kw17.7~1000Kw101~176Kw凝水管径DN20mm25mm32mm40mm7采暖系统统(另外单单独设计)7.1、冬冬季热负荷荷的计算空调热负荷是指指空调系统统在冬季里里,当室外外空气温度度在设计温温度条件时时,为保持持室内的设设计温度,系系统向房间间提供的热热量。对于于民用建筑筑来说空调调冬季的经经济性对空空调系统的的影响要比比夏季小。因因此,空调调热负荷一一般是按稳稳定传热理理论计算的的。7.1.1、围围护结构的的基本耗热热量Q1=aFK(tnn.-tw.)(5-9)式中:a-----------温差修正正能够系数数,W;F------------围护结构构传热面积积,m2;K------------围护结构构冬季传热热系,W/((m2.℃);tn----------冬季室内内计算温度度,℃;tw.-----------冬季室外外空气计算算温度,℃;包括基本耗热量量和附加耗耗热量,附附加耗热量量按基本耗耗热量的百百分率确定定。此建筑筑只考虑朝朝向修正率率。北:0;东西:-5%;南:-20%。注:由于空调建建筑室内通通常保持正正压,因而而在一般情情况下,不不计算门窗窗缝隙渗入入室内的冷冷空气和由由门,孔洞洞等侵入室室内的冷空空气引起的的耗热量。7.1.2、冬冬季空调新新风热负荷荷Qho=Mocpp(to—tR)(5-10)式中:Qh..o---------冬季新风风热负荷,W;Moo--------新风量,g/s;too--------冬季空调调室外空气气的计算温温度,℃;tRR--------冬季空调调室内空气气计算温度度,℃cpp--------空气的定定压比热,kJ/(kg.℃),取1.0005kJJ/(kg.℃);7.2、热热负荷计算算见下表::名称面积室内计算温度室外空气计算温温度围护结构传热系系数围护结构温差修修正系数基本耗热量朝向修正修正值外门开启附加负荷渗风量每立方米渗风耗耗热量渗风量修正系数数外窗长度渗风耗热量总耗热量一层工人房北外墙7.71000.88168.11168.1068.1西外墙11.31000.88199.79-50.9594.8094.8地面Ⅰ141000.47164.90164.9064.9地面Ⅱ3.21000.2317.55017.5507.55地面Ⅲ0.431000.1210.5010.500.5北外窗2.161003.01165.00165.00.855.50.76471536西外窗2.161003.01165.02-50.9561.770.855.50.356236297.4小计371362.77071070车库卷帘门9.9504.211208.4-200.8166.70.857.690.112.6198364.4西外墙15.84500.88169.7-50.9566.21066.21地面Ⅰ12.9500.47130.00130.0030.0地面Ⅱ4.43500.23315.161015.16105.161西外窗4.32503.01165.02-5165.020.853.650.3512313377.7小计378.3333.1510.4843.5餐厅北外墙7.741600.881109011090109东外墙9.91600.881139.4-50.95132.40132.4地面Ⅰ8.241600.465161.310161.31061.31地面Ⅱ1.11600.23314.101014.10104.101北外窗2.161603.011104011040.857.690.76659762.9北门2.61604.651193.4012386.90.857.690.72.4264650.4小计611.2797.79221720厨房东外墙4.141800.88165.58-5165.58065.58南外墙3.421800.88154.170154.17054.17地面Ⅰ3.231800.465127.040127.04027.04地面Ⅱ1.721800.23317.214017.21407.214东外窗2.161803.011117-50.95111.20.855.50.76471582.4小计271265.2471736.4浴室东外墙2.082500.88145.76-50.9543.47043.47地面Ⅰ2.042500.465123.720123.72023.72地面Ⅱ0.42500.23312.33012.3302.33东外窗1.622503.011121.9-50.95115.80.2410.980.75.4239354.9小计185.3239424.4客厅南外墙7.81600.881109.801109.80109.8东外墙10.81600.881152.1-50.95144.50144.5地面Ⅰ22.781600.4651169.501169.50169.5地面Ⅱ12.541600.233146.750146.75046.75地面Ⅲ12.161600.116122.570122.57022.57东南玻璃5.091603.011245.1-100.9220.60.857.690.11.2719.9240.5西南玻璃5.091603.011245.1-100.9220.60.857.690.251.2749.8270.4南面玻璃5.091603.011245.1-200.8196.10.857.690.12.742.4238.5南门4.51604.651334.8-200.81.8482.10.857.690.14.8676558.4小计16131881801盥洗室北外墙6.31800.88199.790199.79099.79地面Ⅰ3.721800.465131.140131.14031.14北外窗2.161803.011117011170.858.420.76721838.5小计248721969.4二层卧室西北外墙7.741800.881122.601122.60122.6西外墙11.341800.881179.6-50.95170.60170.6北外窗2.161803.011117011170.858.420.76721838.5西外窗2.161803.011117-50.95111.20.858.420.356361471.9二层顶棚层14.851800.971345.701345.70345.7小计867.210821949起居室西外墙16.381800.881259.5-50.95246.50246.5南外墙7.741800.881122.6-200.898.08098.08西外窗4.321803.011234.1-50.95222.40.858.420.3512721943.8南外窗2.161803.011117-200.893.620.858.420.16103196.7二层顶棚层19.81800.971460.901460.90460.9小计11218251946主卧室南外墙7.742000.881136.2-200.81090109东外墙12.62000.881221.8-50.95210.70210.7西外墙1.82000.88131.68-50.9530.1030.1东南玻璃3.392003.011204.1-100.9183.
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 直销团队月度工作策略计划
- 2024-2025学年高中生物 第三章 基因的本质 第3节 DNA的复制教学实录2 新人教版必修2
- 加强班级自我管理的路径计划
- 大班心理辅导活动的实施计划
- 工作中的多元化与包容计划
- 将企业愿景融入工作计划中
- 幼儿园小小志愿者活动计划
- 我说你搭(教案)2024-2025学年数学四年级下册
- 幼教工作总结汇报
- 江西省九江市少年宫科学能源世界课程(教学设计)-钻孔机
- GB/T 15622-2023液压缸试验方法
- 110kV升压站构支架组立施工方案
- CONSORT2010流程图(FlowDiagram)【模板】文档
- 2014年林产化工松香深加工行业分析报告
- 2023机场海关旅检岗位练兵练习试题及答案
- 沉淀滴定法-沉淀滴定法原理
- 游戏综合YY频道设计模板
- GB/T 43102-2023金属覆盖层孔隙率试验用亚硫酸/二氧化硫蒸气测定金或钯镀层孔隙率
- 糖尿病中医症状积分
- 灰姑娘童话故事英文版课件
- 儿科病房护理风险915课件
评论
0/150
提交评论