单双排ct竞争对手spirit0.8camera l_第1页
单双排ct竞争对手spirit0.8camera l_第2页
单双排ct竞争对手spirit0.8camera l_第3页
单双排ct竞争对手spirit0.8camera l_第4页
单双排ct竞争对手spirit0.8camera l_第5页
已阅读5页,还剩13页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

SOMATOMSpirit0.8CameraStandardQuotationTo:STANDARDCUSTOMERCTOfferNo.:9CT09-00178Date:01.02.2008To:STANDARDCUSTOMERCT标准报SOMATOMSD_000_C2-1SOMATOMSOMATOMMultislicecomputedtomographyscannerforefficientwholebodyexaminations.Thecontinuouslyrotatingtube-detectorsystemacquirestwoslicesperrotation.SOMATOMSpiritisaCTscannerfordailyroutine–itenablesstandardCTexaminationsand3Dpostprocessing.SOMATOMSpirithasbeendesignedforexcellentimagequalitywithlowradiationexposure.TheCTscannerexcelsthroughitsintuitiveoperation,userguidanceandexpedientautomatedworkflow.AcomputedtomographyscannerwithanappealingandtrendsettingSOMATOMSpiritsystemsurveyHighgantryrotationspeedwithpremiumdetectorsystemforfastimageacquisitionandreal-timedisy.Excellentvisualizationoffineboneandsofttissuestructures,withafinestructureresolutiondownto1.0mm.PatentedUFC-UltraFastCeramic-detectormaterialforfastacquisitionoflargevolumeswithoutstandingresolution.SureViewTM-multisliceimagereconstructionsystem.Consistentimagequalityatanyscanspeed,independentofselectedpitch(pitchselectablebetween0.5and2.0).CAREDoseReal-timedosemodulationallowsdoessavingsofupto56%withoutcompromisingimagequality.High-contrastresolution-0%MTF(±10%):15.5syngouserinterface-easyandintuitiveoperation,userguidanceandautomatedworkflow,whereexpedient.Uniformworkingenvironmentforanduniquenetworkingofimagingtechniques.Toolsforfast3Dpostprocessingforeffectivevisualization,ysis,ficationandationofclinicalstructures.(reconstructionspeed:3s/image).Imagedisyin1024x1024matrixonflicker-48cm(19")flatscreen(fordeliveriesbeforeNovember2005a17"monitorisdelivered)Slimgantry(68.5cm)withwideaperture(70cm)increasespatientcomfortandexaminationspeedandenablegoodpatientaccess.Smallfootprint(17m2)andfastinstallationduetocompactsystemHigh-efficiencyaircooledsystem-nowatercoolerAppealing,trendsetting2SpiritStandardSOMATOMSpiritRotationspeedoftheacquisitionsystem60rpmwitharotationspeedof1.0s(0.8sSystemconfigurationconsistsof:Scanningunit(gantry);2.0MHUDURAX-raytube;patientpositioningtable;controlandevaluationconsole;26kWX-raygenerator;computersystemandstorage;SureView™multisliceimagereconstructionsystem;CAREDose4D;syngousersoftwareandnetworkmodule.SOMATOMSpiritsystemconfigurationinGantryaperturediameter:70cm,tiltangle:±25degrees.Gantryrotationspeed:60rpm;rotationtime/revolution:1.0second.UFCdetector:dual-rowCTmeasurementsystemdesignedforoptimumimagequalitywithminimumpatientdose(specifiedlowcontrastat90mAs).1344measuringchannelsallowexcellenthigh-contrastandlow-contrastresolutioninconnectionwiththepatentedUFCdetector(UltraFastCeramics,patent).High-performancerotating-anodetubeDURA202-MV,max.tubepower:26kWatAnodeheatstoragecapacity:1.3MJ=2.0MHU;focalspotsizes:0.8x0.4mm,0.8x0.7mm(IEC336/93);High-voltagerange:80and130kV;tubecurrentrange:30-180PatientMotor-driventableheightadjustment:45-83cm(measuredatuppertablesurface);scannablerange(metal-):145cm.Positioningaccuracy:±0.25mm.Operationpossiblefrombothsidesofthegantry.Manualoperationpossibleincaseofemergencystoporpowerfailure.PositioningPositioningmatforcomfortableandconvenientpatientpositioning.ThematisattachedtothetabletopbymeansofVelcrotapes.headholderforpositioningthepatient'scushionsetforthecomfortableandsafepositioningofthepatient'sheadintheheadpositioningaidforcomfortableheadandarmpositioningduringexaminationsofthechest,abdomenandlumbarspineanatomicallyshapedcushionforreducingspinecurvatureduringlumbarspineexaminationsandforcomfortablepositioningofthelegsduringallexaminationsheadholderforstandardpositioningofthecoronalsupineheadsetofrestraintstrapsforthesafepositioningofthepatientonthepatientadditionalpositioningaccessoriesControlandevaluationControlelements,keyboard,CTcontrolboxandmouse. systemwithuser-progrblepatientinstructionsystem.Deskandcomputercabinetoptional.X-rayDURAMATICmicroprocessor-controlled,low-noise,high-frequencyX-raygeneratorwithintegrated,automaticself-testsystemforcontinuousmonitoring.Parameters:high-voltagerange:80and130kV;tubecurrentrange:30to180mA,max.power:26kW,fineadjustment.ComputersystemandIMS(ImageManagementSystem)consistingofIRS(ImageReconstructionSystem)andICS(ImageControlSystem).TheIRSpreprocessesandreconstructstheCTdataandstoresthecurrentrawdata.Reconstructiontime:upto5images/second.TheICSnsandexecutestheCTexaminationincludingevaluationandmanagementofCTimages.Magneticharddiskstorageunitwith146GBfordigitalstorageofimagesandrawdata.Storagecapacity:atleast240,000imagesof512x512matrixpressedandapprox.6,000scansecondsofrawdata.ThecomputersystemincludesaCDread/writedriveforofflinestorage.Storagecapacityper700MBCDmedium:atleast1,100imagesin512x512matrix SPIRALContinuousvolumescanningtechniquewithuninterruptedtablefeedinthemulti-rotationmode.Max.scantimeandscanrange:60secondsand145cmvolumelengthatfullimagequality-low-contrastresolution.Automaticpitchselectionbetween0.5and2.Rotationtimeperrevolution:1.0and1.5seconds,optional0.8s.Tablefeedspeed:1-100mm/sSureViewTM-MultisliceImageReconstructionSureViewisthespiralimagereconstructionsystemforallmultisliceCTEasy-to-usescanprotocols-userselectsscanvolume(range),mAs,scantimeandslicewidth.AllotherparametersareautomaticallycalculatedbytheCTscanner.Multiplytheclinicalperformanceofyourscanner-anypitchfactorbetween0.5and2canbeautomaticallyselectedbytheCTscanner-withconstantIQandnosliceExcellentimagequalitywithanypitchfactor-IQremainsconstantwithanyscanspeed,independentoftheselectedscanrangeandscantime.Upto20%dosesavingsinspiralCAREDoseThissoftwarefeatureprovidesautomatic,real-timeX-raydosemanagementforallscanmodes.TheminimumX-raydoselevelneededtoobtainoptimalimagequalityisdeterminedfromextensivecomputerysisofthetopogramimageandalsofromthedatacollectedduringeveryslicescanned,onareal-timebasis.ThisautomaticapproachensuresoptimalimagequalityatthelowestpossibleX-raydose.Withthismethodofdosecontrol,theinitialorstartingtubecurrentforeveryaxialslicepositionisdeterminedfromtheTopogramimage.Then,duringthedataacquisitionforeachaxialslice,theX-rayattenuationvaluesarecloselymonitoredandthetubecurrentisadjusted,onareal-timebasis,tooptimizetheX-raydoselevelforthespecificorgansandanatomyintheX-raypath.SeveralclinicalbenefitsareachievedwithCAREDoseSignificantx-raydosereduction(upto68%)possibleforallbodyregionsscannedcomparedwithstandardsequenceorspiralscanning;Consistent,optimalimagequalitywiththex-raydoseleveluniqueforeverypatientandforeveryanatomicalregion;Thinneraxialslicesand/orlongerscanrangespossiblebecauseofreducedtubeUltra-lowdoseexaminationsforpaediatric9.syngousersoftwaresyngofeaturesanintuitiveandthuseasy-to-learnuserinterfacedevelopedfromprototypestestedinclosecooperationwithcustomers.Theexaminationisperformedinindividualprocessstepsontheusertaskcards,suchaspatientregistrationorexamination.Anumberoffunctionsandinputparameters,aswellasthelanguageused,canbeselectedaccordingtoindividualrequirements.PatientThepatientacceptspatientdataindifferentways.Theseincludeenteringthedatafromthekeyboardortransferringaworklistviathenetwork.Worklist:SoftwaremoduleforacceptinglistsofpatientdataandexaminationrequirementsfromaRadiologyInformationSystem(RIS)via GetWorklistfunctionality.Theprogramenablesveryefficientworkflowandensuresconsistentpatientdata.Inemergencycases,fastregistrationispossible.Inthiscasethesystemautomaticallyassignsanemergencynumberwhichcanlaterberecedbythecorrectpatientdata.Theinputprofilecanbeindividuallydefined.ExaminationThescannerisprogrammedwithalargenumberofpredefinedexaminationprotocols,makingexaminationnningaveryfastandefficientprocedure.Example:The3-phaseliverscanprotocolispreprogrammedandonlyneedstobeadaptedtospecificpatientTheuserguidanceintegratedintheexaminationcardhelpstheuserperformtheexamination.Theuserisguidedthroughtheexaminationstepbystep.Onlytherelevantinformationisshownineachviewandtheselectionandentryfieldsarecustomizedtotheview,providingtheuserwithacleardisy.Examination-specificentriesandadjustmentscanbeperformedquicklyandeasilywiththemouse.ViewingOntheViewingcarditispossibletomoveinctivelywiththemousethroughtheimagevolumeoftheongoingexamination.Theimagesofd ationscanbe reavailableforevaluation,FilmingAvirtualfilmsheetshowsapreviewofthefilmsheetstobeprintedonalasercameraorprinter.Imagere-windowing,auto-filmingparalleltoimageacquisition/reconstructionandalargenumberofevaluationfunctionsarealsopossibleontheFilmingcard.3DThe3DtaskcardcomprisestheuserinterfaceforoperatingtheMIP(umIntensityProjection),SSD(SurfaceShadedDisy)andMPR(MultinarReconstruction)three-dimensionalpostprocessingtools.Upto3imagesetsfromdifferentpatients-preferablywithslicesthinnerthan3mm-canbeloadedsimultaneouslyintothe3DcardandpostprocessedwithMIP,SSDandMPR.OthertaskcardsandfunctionssuchassyngoVRT,syngoOsteoCT,syngoDentalCTandsyngoFlyThroughareavailableasoptionsiftheapplicationsareinstalled.ExaminationandevaluationScannings:anterior-posterior(ap),posterior-anterior(pa),lal(lat);scanfieldlengths:128to1024mm;scanfieldwidth:512mm;upto9differentexaminationSizeofscanfield:50Scantimes:1.0und1.5secondsaswellas2-foldmulti-rotationscans.Slicethicknesses:2x1;2x1.5;2x2.5;2x4;and2x5mm;High-voltagevalues:80kVand130kV;Tubecurrent:30to180mAin19Automatedscansequenceswithcycletimesof2.5seconds.Programforfunctionaldynamicstudies.Serialscanningtechniqueinasingleslicepositionwithvariablescancycletimestoexaminetime-relatedcontrastmediumdynamics.Thescanseriesistriggeredatthecontrolconsole.Cycletime:2.5secondswithupto99scansinuninterrupted,continuoussequence.Scantime:1.0and1.5seconds.Inter-scantime:1second.AsynchronousAsynchronousReconallowsformultipleimagereconstructionsandreformatsparalleltoscanning.Withthisfeature,upto3reconstructionjobrequestscanbeloadedintoascanprotocol.Immediayuponcompletionofthescanacquisition,thesereconstructionjobsareautomaticallyexecutedinthebackgroundwithoutdelayingthestartofthenextpatientImagereconstruction,512x512reconstructionmatrix,reconstructiontime:1second/image,reconstructionfieldsof5cmto50cmusingrawdatazoomwiththepossibilityoflyselectingtheimagecentereitherbeforescanning(prospectively)orretrospectively.Patient-relatedstorageofimageandrawdata.Imagedis1024x1024disymatrix;selectablescreensplittingofmonitordisyinto1,4,9or16imagesegments;1280x1024imagematrix;CTvaluescaleforwindowsetting-1024toHU.ForverydenseobjectstheCTvaluescalecanbeextendedfrom-10240toImageComplete,software-guidedimageevaluationprogramforalldiagnosticMultinarReal-timeMPRforreal-timereconstructionofsecondarySliceorientation:coronal,sagittal,irregularaswellasmultinarwithSIRandOblique.Cutlinescanbedeterminedusingthereferencetomogramorinsagittalreformattedimages(SRI).512x512reconstructionmatrix.CTSoftwareprogramforthereconstructionofobliqueprojectionsfromtheimagesofaspiraldatafile,forthedisyanddiagnosisofaneurysms,ques,stenoses,vascularanomaliesorvascularorigins.Theobliqueprojectionsarereconstructedaroundapre-definedaxis,wherebyforeachobliqueprojection umCTvalueinthisisselected.Theresultingseriescanbeviewedwitha3DimageeffectusingtheCinesyngo3DSoftwareprogramforthethree-dimensionaldisyofsurfacesfromaseriesofcontiguousslices.Usedtodis hips,forthepurposeof tiltedandrotatedonthemonitorand/ordisyedinnon-transaxialviewsinrealRealTimeDisSoftwareprogramthatprovidesinstantaneous512x512imagedisycoincidingwiththeactualtube/detectorposition.Thisfeatureisespeciallyusefulforsituationswhenreal-timeviewingofascanisdesired.CINEDisPresentationtechniquefortime-relatedprocessesand3Dsurveyofanentireanatomicregionachievedwithafastframerate.Aseriesofupto1,000imagescanbedisyedina512x512imagematrixatarateof10f/s.MultitaskingSimultaneousprocessingduringMETROForSEQUENCEandSPIRALscans:Imagereconstructioncanbeperformedparallelto minedpatientwhilecurrentpatientisbeingMETROAutomaticimagetransferto nodeintheMetroAutomaticarchivaltoanoptionallocalarchiveNetworkFortheconnectiontoalocalEthernetnetworkforcommunicationwithnetworkprinters,diagnosticandtherapyworkstations,RISsystemsanderadiologyrouters.ScopeofConfigurablenetworkUnlimitedselectionofSupportof 3.0standards(DigitalImagingandCommunicationsinMedicine)forthetransferofinformationbetween compatibleunitsfromdifferentmanufacturers.ThescopeoffunctionsisdescribedindetailintheConformanceStatementandcomprisesthefollowingstandardGetWorklistStorageMPPS(ModalityPerformedProcedureImagedataexchangewithMRandtherapyunitsaswellasworkstationsanderadiologyrouterswhichsupportthe 3.0standardExchangeofCTimageswithotherunitsoftheSOMATOMCTfamilyvia3.0Simultaneousationofimagesfromanypreviouslyexaminedpatientduringthecurrentexaminationonaselectablenetworkprinterwhichsupports" ConnectiontoRIS/HISsystems Worklist)forthetransferofpatient1-GigabitnetworkNoteonuseoftheUseoftheentireintegratedsoftwarepackageincludingoptionalsoftwareprogramsisrestrictedsolelytoapplicationswiththissystemunit.ThisproductisincompliancewithIEC60601-1-2andfulfillsCISPR11ClassA.Note:Inadomesticenvironmentthisproductmaycauseradiointerference.Inthiscasetheusermayberequiredtotakeadequatemeasures.SOMATOMSpirit是一台多层CT,进行高效的全身螺旋扫描。球管和探测器系统连续旋转,每圈两幅图像。为日常检查的需要,SOMATOMSpirit既可以进行常规CT检查,(26KW);计算机及系统;实时剂量调控技术(CAREDose);新沟通用户操作-专利的西门子UFC探测器——速稀土陶瓷探测器材料,以优异的图像分辨率快速获-自由螺距(SureviewTM)——多层CT图像重建系统。在任意扫描速度下,图像质量均无-实时剂量调控(CareDose)技术——实时调节剂量,在不影响图像质量的情况下,5幅/-薄型机架设计(68.5cm)(70cm)提高了患者舒适性和检查速度,可以进-紧凑合理设计,安装面积小(17m2),安装快本产品符合IEC60601-1-2和CISPR11ClassA的要求。注意:本产品在使用中可能产生无线SOMATOMSpirit系统配置扫描架速稀土陶瓷探测器UFC:双排CT系统,采用最低辐射剂量(达到低对比分辨率时为90mAs)即可获得最佳质量图像,1344个速稀土陶瓷探测器(UFC,西门检查床床垫、头托、头托垫、体部检查头托、膝关节托、托、头部标准固定托架、冠状控制和诊断台-用户自行编程控制的对讲指导系统;X线发生器计算机系统和系统压缩;并约6,000扫描秒的原始数据。系统可以配置标准CD刻盘机,容量每张700MB光盘,可幅 螺旋扫描自由螺距-多层CT影像重建软件自由螺距是用于西门子多层CT螺旋扫描图像重建的软件1-4之间,计算机自动选择任意螺距,保证影像质量一致优异,自动剂量调控X线透过患者身体不同位置和不描过程中,系统实时X线衰减并实时调节球管电流,对于扫描过程中的不同和组新沟通用户软件程按不同步骤分成几个任务卡,例如登记卡及扫描卡等。用户可以根据不同的需要选系统能够用不同的方法对进行登记。采用键盘输入或

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论