sbl-ep16高低压开关柜培训中法文kyn6140.5安装使用说明书_第1页
sbl-ep16高低压开关柜培训中法文kyn6140.5安装使用说明书_第2页
sbl-ep16高低压开关柜培训中法文kyn6140.5安装使用说明书_第3页
sbl-ep16高低压开关柜培训中法文kyn6140.5安装使用说明书_第4页
sbl-ep16高低压开关柜培训中法文kyn6140.5安装使用说明书_第5页
已阅读5页,还剩80页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

--PAGE4 铠装式金属封闭开关设备安装使用OperatingManualforKYN61-40.5Metal-cladEnclosed青岛特锐德电QingdaoTGOODElectricSafetyReadthismanualcarefullybeforetheswitchgearisinstalledandusedTheswitchgearcanonlybeinstalledinthecesuitablefortheoperationofelectricequipment.Theswitchgearisonlyinstalled,operatedandservicedbythefull-timeelectricaltechnicians.Ensurethattheconnectionconditionsandworkingproceduresfortheelectricalequipmentaresuitableandsafe.Fortheoperationoftheswitchgear,followtherelevantprovisionsintheoperatingmanual.DangerItisimportanttopayspecialattentiontotheprecautionstheswitchgearwithDangerDon'texceedtheloadsprescribedinthetechnicalparametersundernormalworkingconditionsoftheswitchgear.Thefull-timeelectricaltechniciansshallberesponsibleforallthemattersthataffecttheoperationandproperlyservicetheIfyouhaveanyquestionabouttheoperatingmanual,wewillbegladtoprovideyouwithfurtherinformation.,将本说明书的全部或部分,以提供给第三者。公司保留对提供的数据和图解的更改权力,需更改时,不另行通知。Allrights .Itisforbiddentoprovidetheoperatingmanual,inwholeorinpart,inanyformtothethirdparty.Ifnecessary,wehavetherighttochangethedataanddiagramswithoutpriornotice.一、总则 (一)概述 (二)标准和规范Standardsand (三)工作条件Working 正常工作条件Normalworking特殊工作条件Specialworking注意事项 二、技术数据Technical 开关柜电气参数Electricalparametersof 耐内部故障电弧性能Anti- 外形尺寸和重量Dimensionsand 三、开关柜结构概述Overviewaboutswitchgear 基本结构Basic 外壳和隔板Enclosureand 开关柜内的小室Smallroominthe手车室Handcart 断路器手车Circuit-breaker 母线室Bus-bar 电缆室Cable 仪表室Control (四) 防止误操作的联锁保护Interlockingdevicestopreventthewrongoperation 四、和保管Transportand 交付条件Termsof 包装 Transport 交货和中间保管Deliveryand 五、开关柜的现场安装On-siteinstallationof (一安装现场的一般要求Generalrequirementsforon- (二)配电室平面布置基本方案Generalnning switchingroomlayout (三)基础 以配电室地板作为基础Taketheswitching-roomfloorasthefoundation 混凝土地坪上的基础框架(图3)的安装Installtheswitchgearonthefoundationframeworkontheconcretefloor(figure3) (四)现场安装On-site (五)母线的安装联接Bus-bar (六)电力电缆和控制电缆的联接Connectionofpowercableandcontrolcable (七接地铜排的联接Connectionofgroundingcopper-bar(八)安装工作的收尾Finalworkof 六、开关柜的运行Operationof 起动 准备工作 交接试验Commissioning 起动 开关柜的操作Operationof 断路器手车Circuit-breaker 接地开关Grounding 电缆室门Cable-room 七、 (一)概述 (二)检查和保养Inspectionand (三)修理 一般性修理General 更换元件Recethe (四)备件Spare -8--9一、总则KYN61-40.5是一种高品质的并已通过型式试验认证KYN61-40.5switchgearisakindofhighqualityairinsulatedswitchgear,whichhasbeencertified.KYN61-40.5铠装式金属封闭开关设备(KYN61-40.5metal-cladenclosedswitchgear(hereinafterreferredtoasKYN61-40.5switchgear)isusedin3-phaseAC,50Hzand35kVsinglebus-barandbus-barsectionpowersystemandithasthefunctionof“Five-prevention”.ThemovablepartsoftheswitchgearcanbeprovidedwiththevacuumcircuitbreakerandotherStandardsand--PAGE20KYN61-40.5switchgearmeetsIEC298,GB3906andDL404standards. 手车移开时,防护等级为IP2X。TheprotectiongradeofswitchgearenclosureisIP4X.Whenthedoorofthecircuit-breakerroomisopenedandhandcartismovedaway,theprotectiongradeisIP2X.Duringtheinstallationandoperationofthesystem,followalltherelevantIECstandardsandrelevantnationalorlocalsafetyguidelines.TherelevantinformationprovidedbyQingdaoTGOODElectricCO.,shouldalsobeconsideredfully.NormalworkingThenormalworkingconditionsforKYN61-40.5switchgearareasfollows:室内环境温度:Indoorenvironment +35° - -Indoorenvironment 95%orbelow 90%orbelow 1000m及以下 1000morbelow Nomorethan8Theinstallationsiteshallbewithoutfire,explosion,seriouspollutionandchemicalcorrosion.SpecialworkingForspecialworkingconditions,consultthemanufacturer.Themanufacturershouldreachanagreementonspecialworkingconditionswithuser.Whentheswitchgearisinstalledinthecewiththealtitudehigherthan1000m,thereductionofairdielectricstrengthmayaffecttheinsulationIftheambienttemperatureexceedsthelimit,thebus-barandbranchbus-barshallbedesignedtocompensateorlimitthecarryingcapacity.Theventilatingntshallbeinstalledintheswitchgearinorderfortheheatdissipation.的,因此开关柜在备用和运行状态下,用户应保Iftheswitchgearisinstalledinthecewithhighhumidityandbiggertemperaturefluctuations,thereistheriskofcondensationinsuchaclimateenvironment.Whentheswitchgearisinthestandbystatusoroperatinginsuchaclimateenvironment,theusershouldguaranteetheheateroperates24hours/aday!Whentheswitchgearoperatesinthelargecurrent,theheatercannotbe二、技术Technical开关柜电气参数ElectricalparametersoftheswitchgearRated额定1min绝缘(有效值雷电冲击耐压(峰值voltageRatedRatedbus-barA A short-current(effectivevalue)额定动稳定电流(RateddynamicAnti-internalfaultarcKYN61-40.5开关柜在设计上已考虑到开关柜内部故障电弧的问GB3906和IEC298进行了严格的WhenKYN61-40.5switchgearisdesigned,thefaultarcoftheswitchgearhasbeengivenafullconsideration.ThestricttesthasbeencarriedoutaccordingtoGB3906andIEC298andthusthesafetyofequipmentandoperatorscaneffectivelybeensured.Dimensionsand高度a宽度b高度a宽度b深度c高度a宽度b高度a宽度b ZN85ThefollowingswitchgearhasbeenprovidedwithZN85circuitbreaker.A:Relayroom B:Bus-barroom C:Circuitbreaker D:Cableroom40.5kVMetal-cladEnclosed图1:KYN61-40.5进线或出线柜基本Fig1:ThebasicstructureofKYN61-40.5 andoutgoing-lineswitchgear开关柜结构概述Overviewaboutswitchgear表室。图1展示了柜体的结构电器设备的安装。Themainstructureoftheswitchgeariscomposedofthehandcartroom,bus-barroom,cableroomandcontrolroom.Figure1showstheswitchgearstructureandtheelectricalequipmentinstallation.外壳和隔板Enclosureand2mm敷铝锌板组装而成。泻采用粉末喷涂以防腐蚀且可打开近180度Theenclosureoftheswitchgearismadeofthehigh-quality2mmcoatedaluminumzincte.Thepressurereducingteisinstalledatthetopofthehigh-voltageroom.Whenthehighpressureisproducedbytheinternalarc,thepressurereducingteisopened.Theadjacentswitchgearisseparatedbythesidepanel.Allthedoorsarecoatedwiththepowdersinordertopreventthecorrosionandallthedoorscanbeopenedtonearly开关柜内的小 Smallroominthe手车室Handcart电体。可移开单元在试验/位置时手车室门仍可完Thehandcartroomisprovidedwiththeguiderailinordertoensurethatthemovableunitcanmovebetweentheworkingpositionandtest/isolationpositionreliably.Whenthemovableunitreturnsfromtheworkpositiontotest/isolationposition,thevalveisautomaticallyshutdowntopreventtouchingthelivepart.Whenthemovableunitremainsinthetest/isolationposition,thehandcart-roomdoorisfullyclosed.Atthispoint,thecircuit- energy-storage/noneenergy-storageindicatorcanbeobservedbyuseoftheinspectionwindow.Whenthecircuitbreakerisoperated,thefrontdoorshouldbeclosed.Thehandcartcanbemovedmanually.Theframeworkisassembledtogetherbyuseofthealloysteeltesandisprovidedwiththecircuitbreakersandotherequipment.Thecontactarmwiththespringcontactismountedonthepolerodofthecircuitbreaker.Whenthehandcartisinsertedintotheoperatingposition,itactsasanelectricalconnection.Thesignal,protectionandcontrollinebetweenthehandcartandswitchgearisconnectedbyuseofone-lineplug.Oncethehandcartisinsertedintotheswitchgear,itisfixedtothetest/isolationpositionandalsoconnectedtotheswitchgeargrounding-system-21-21reliably.Thehandcartpositioncanbeobservedbyuseoftheinspectionwindoworthehandcartpositionindicatormountedonthecontrol-roompanel.Bus-bar缩套管覆盖。套管板和套管将柜与柜之间的母线Thebus-barisledfromtheswitchgeartootherswitchgearandisfixedbyuseofthebranchbus-barandbushing.Therectanglebranchbus-barisconnecteddirectlytothemainbus-barwiththebolts,withoutanyconnectingclamp.Allthebus-barsandbranchbus-barsarecoveredwiththeheatshrinkablebushings.Thebus-barsbetweentheswitchgearareisolatedandsupportedbyuseofthebushingtesandbushings.Fortheswitchgearwithbigelectro-dynamicstress,thissupportisneededgenerally.--PAGE39Cable工人员进入柜内安装电缆。盖在电缆处的底板可Thecurrenttransformerandgroundingswitchareinstalledatthebackofthecableroom.Thecableroomcanalsobeprovidedwiththelightningarrester.Whenthecable-roomdoorisopened,therewillbetheenoughspacefortheelectricaltechnicianstoentertheswitchgeartoinstallthecables.Thefloorsatthecableentrancecanbemadebyuseofthenonmagneticstainlesssteeltes,whichareslottedandremovablefortheelectricaltechnicianstoinstallthecables.Thereducingseal-ringopeningsthattheprimaryandsecondarycablespassthroughshouldbesuitableforthecablesizetopreventthesmallanimalstoenter.Forthecabletrenchwithlargerhumidity,itmendedtousethefireclayorepoxyresintosealthecabletrench.ControlThesecondarycomponentsaremountedinthecontrolroomorthedoor.Thesidepanelofthecontrolroomhasthecablepunched-holesinordertocontrolthepower(四)防止误操作的联锁保护Interlockingdevicestopreventthewrongoperation具备一系列的联锁装置,从根本上防止出现局面和可能引起严重的误操作,因此有效地保护了操Itisprovidedwithaseriesofinterlockingdevices,whichcanfundamentallypreventadangeroussituationaswellasthewrongoperationthatmaycausetheseriousconsequencesandeffectivelyprotecttheoperatorandswitchgear.Theinterlockingfunctionisasfollows:断路器和接地开关在分闸位置时,手车能从试验向移动也行(机械联锁Whenthecircuitbreakerandgroundingswitchareintheswitch-offposition,thehandcartcanmovefromthetest/isolationpositiontotheoperatingposition.Inthisstate,thehandcartcanalsomovereversely(mechanical闸(机械和电气联锁Whenthehandcartiscompleyinthetestingoroperatingposition,thecircuitbreakercanbeswitchedon(mechanicalandelectricinterlocking).(电气联锁Whenthehandcartisinthetestingoroperatingpositionwithoutcontrolofthevoltage,thecircuitbreakercannotbeswitchedonandcanonlybeswitchedoffmanually(electricinterlocking).Whenthehandcartisintheoperatingposition,thecontrollineplugislockedandcan'tbepulledout.Onlywhenthemovableunitisinthetest/isolationpositioncanthesecondaryplugbepluggedinand(机械联锁Whenthehandcartisintest/isolationpositionorisremoved,thegroundingswitchcanbeswitchedon(mechanicalinterlocking).行位置(机械联锁Whenthegroundingswitchisturnedoff,thehandcartcan'tmovefromthetest/isolationpositiontotheoperatingposition(mechanicalinterlocking).Whenthegroundingswitchisturnedon,thebackdoorcanbeopenedtopreventthe swronglyenterintothelivecompartmentOnlywhenthebackdoorisclosedcanthegroundingswitchbeturnedoff.可在手车和/Thehandcartand/orgroundingswitchoperatingmechanismcanbeprovidedwiththeadditionalinterlockingdevicessuchaslatchingelectromagnet.Itshouldbemadeclearwhenthecustomercesan2:KYN61-40.5 ing-lineoroutgoing-lineswitchgear四、和保管Transportand交付条TermsofIEC298GB3906有关规定进行出厂试验,校核Inadditiontoinspectionaccordingtotheorder,theassembledswitchgearshouldbeinspectedaccordingtotherelevantprovisionsofIEC298andGB3906standardstocheckthecorrectnessofthestructureandfunction.Thebus-bars,fastenersandaccessoriesareindividuallypackaged.包 海包装或不包装。特别是海上,即使是装在集装Thepackagingoftheswitchgearshallbeadjustedcorrespondinglyaccordingtotherequirementssuchassailingpackagingornon-packaging.Inparticular,whentheswitchgearisshippedontheseaandevenifitispackagedincontainer,thestic-filmbagshallalsobeusedtopackagetheswitchgear.Thedesiccantsshallbeputinthecontainertopreventtheswitchgearfrombeingaffectedwithdamp.Transport通常由单台开关柜组成单元,例外情况下,可由开关柜小组或背靠背安装的开关柜组成单元。每台开关柜都装有4个。NormallythetransportunitconsistsofsingleIntheexceptionalcase,thetransportunitcanbecomposedoftheswitchgeargroupinstalledback-to-back.Theswitchgearisprovidedwith4liftinglugs.TheswitchgearshouldbetransportedThemeasuresmustbetakentoprotectthesafetyofsandequipment.Whenloading,oneofthefollowingtoolsmustbeItisloadedbyuseofcrane,forkliftorartificialItisloadedbyuseof吊绳应有足够的承载能力,吊钩开启宽度应Theliftingropeshouldhavetheenoughcarryingcapacity,andtheopeningwidthofthehookshouldbe联接吊钩的绳子和水平线之间的角度应保持在Theanglebetweentheliftingropeandthelineshouldkeepabove60Whentheswitchgearislifted,itisallowedfortheliftinglugstohaveacorrespondingbending.Whentheswitchgeararrivedatthesite,theconsigneehastheresponsibilityto(butnotlimitedto)dothefollowing通知我公司现场服务售后工程师去参加开箱验收Informourafter-salesengineerstoattendtheCheckandseewhetherthearrivedgoodsarecompleteandarenotdamagedornot.Checkandseewhetherthesarecompleteandtheoperating existornot.Ifthereisanydoubt,unpackinspect.Iftheswitchgearneedstobestored,thedesiccantmustbeputinandtheswitchgearneedstobesealedagain.Ifthedetailedrecordsarefoundtorunshortorsomedefectsarefoundorsomedamagesarefound,informtherelevant atonce.Pleasenotethatwhenstored,theswitchgearshouldbecedinapositionwhichisnotharmfultotheswitchgearandinstallationmaterials.TheunpackingproceduresareasFirstofall,removetheroofingteofpackingcase,thenremovethesidetesandfinallyremovetheboltstoconnecttheswitchgearwithchassis.Pleasenotethattheremovedhexagonsocketscrewsshouldbereinstalledinthepreviouscesandtightened.Byuseof4liftinglugsonthetop,theswitchgearisverticallyliftedtomakeitoutofthechassis.Thenmoveawaythechassis,putintherollbarsunderneaththeswitchgear,usethesticktomaketheswitchgearmoveslowlytotheinstallationsite.Notethatintheprocessofmoving,thereshallbenoheavierimpactandvibration.Pre-packagedorunpackedThestoreroomshouldbedryandwell室内温度不低于-Theindoortemperatureisnotlowerthan-没有其他危害性的Theswitchgearshouldbestoredintheenvironmentwithoutotherharms.TheswitchgearshouldbestoredTheswitchgearcan’tbepiledononeThepackagingshouldnotbe未包装的开关柜,用塑料薄膜松散地遮盖以免弄Theunpackedswitchgearshouldbecoveredlooselywiththesticfilmtopreventtheswitchgearfrombeingpolluted.GoodventilationmustbekepttopreventtheswitchgearfrombeingcorrodedRegularlycheckthecondensationuntiltheinstallationworkbegins. Theswitchgearshouldbestoredinadryanddamp-proofce.CheckandseewhetherthereisanydamageontheThefunctionofpackagingoverthestorageperiodmaybelost.Iftheswitchgearstillneedstobestored,theappropriatemeasuresshouldbetaken.五、开关柜的现场安装On-siteinstallationofToensurethecorrectandhigh-qualityinstallation,theon-siteinstallationoftheswitchgearshallbeonlycarriedoutbyspecially-trainedelectricaltechniciansandalsoyoucaninformustosendtheafter-salesengineerstoguidetheon-siteinstallation.(一)安装现场的一般要求Generalrequirementsforon-siteinstallationAftertheswitchingroomisaccepted,theswitchingroommustbeprovidedwiththepowersupply,lampsandventilationdevices.Theswitchingroomshouldbedry,clean,goodventilationandthedoorcanbelocked.Thewallholesandcabletrenchesshouldbepreparedinadvance.Thecabletrenchesshouldbedugaccordingtotherequirements.Schematicdiagram3isonlyforyourreference.Theceilingheightoftheswitchingroomshouldnotbelessthan3000mm.EnsurethatitcanmeettheindoorswitchgearworkingconditionsprescribedbyIEC,includingindoortemperaturecondition.(二)配电室平面布置基本方案Generalnningofswitchingroomlayout设计配电室平面布置时,按双面考虑,使开关柜Whentheswitchingroomlayoutisdesigned,forthemaintenance,thereshallbethemaintenanceaccessbetweenthebackcover-teandthewallandbetweentheswitchgearboth-sidesandthewall.Thereshallbeawidemaintenanceaccessbetweentheswitchgearandthewallformaintenance.(三)基础Itismoreappropriatetoinstalltheswitchgearonthefoundationframeworkonthefloorintheswitchingroomortheelevatedauxiliaryfoundation.Whenthefoundationislaid,followGBstandard,especiallytheallowabletoleranceinthestraightlineandflatness,thisistheprerequisitestoinstalltheswitchgearperfectly.ThefoundationconstructionshouldcomplywiththerelevantprovisionsofTechnicalSpecificationsforConstructionandAcceptanceofElectricPowerConstruction.以配电室地板作为基础Taketheswitching-roomfloorasthefoundationWhenonlyfewofswitchgearareinstalled,theswitchgearcanbedirectlyinstalledonthefloorintheswitchingroom.Thefloortoinstalltheswitchgearshallbeveryflatandhavetheenoughcarryingcapacity.Ifnecessary,thesuitablegasketscanbeinsertedundertheswitchgearwhen混凝土地坪上的基础框架(3的安装Installtheswitchgearonthefoundationframeworkontheconcretefloor(figure3)5/5所示,开关柜的基础框架埋设一般要求采取Asshowninfigure5/5,thefoundationframeworkforswitchgearshallbegroutedtwotimesaccordingtothegeneralrequirements.Aftertheconstructioniscompleted,thefoundationframeworkshallbepre-embedded.Itismendedthatthefoundationframeworkshallbemadeandpre-embeddedbytheelectricalinstallationunit.Thespecificfoundationframeworkshouldbedrawnaccordingtotherequirementsofthedesigndepartmentandprocessedaccordingtotherequirementsofthe1Whenthefoundationframeworkisconstructed,theelevationofthefoundationframeworkshouldincludetheheightofthefoundationframeworkU-steel.Theanchoringsteelteshallbepre-embeddedattheintervalof1to1.5metersinthewidth.的基本尺寸要求见图3,对槽钢的高度无硬性要求,可以选用[5号或[8号槽钢。基础框架纵向槽钢的外延ThefoundationframeworkisaframestructurewithU-steelandanglesteel.Forthebasicsize,seeThereisnospecificrequirementsfortheheightofU-steel.Generally5#or8#canbeselected.ThelongitudinalU-steelextensionlengthofthefoundationframeworkshouldbeconsistentwiththesizeoftheswitchgear埋设。如图3。在安装阶段,基础框架不应受到撞击Aftertheconstructionofthefoundationframeworkiscompleted,theelectricalinstallationunitshallcetheprocessedfoundationframeworkontothebasicnetoinstall.Usethesteelcushionblockforadjustment.Usethesteeltapeandleveltocalibratethehorizontaland-40-40verticaldirectionofthefoundationframework.Itisallowedthatthelevelerrorislessthan1mmpermeterandtotalerrorisnotmorethan3mm.Itisrequestedthatthetopsurfaceofthefoundationframeworkshouldbehigherthanthefloorelevationoftheswitchingroomabout3to5mm.Itisnotallowedthattheelevationofthefoundationframeworkislowerthanthefloorelevationoftheswitchingroom.Aftercalibrating,thefoundationframeworkandadjustingsizing-blockaretogetherweldedontothepre-embeddedanchoringte.Finally,thefoundationframeworkisembeddedbyuseofthesecondarygrouting.Asshowninfigure3.Inthecourseofinstallation,thefoundationframeworkshouldnotbeimpactedorpressed.Beforethefoundationframeworkisanchoredandgroutedforthesecondtime,thenecessaryacceptanceproceduresshouldbeperformed.图 Fig3:Typicallayoutoftheswitching(四)现场安装On-site8.8的标准螺栓,对应的拧紧扭Usethestandardboltswiththestrengthgradeofnoless6812Tightening-4185--PAGE45Note:DonotaddanylubricatingTransporttheswitchgeartotheinstallationpositionaccordingtotheorderinggivenintheswitchgeararrangementn.Aftertheswitchgearisassembledtogether,fixitontothefoundationframeworkwithfoundationboltsorweldingmanner.Whenthenumberoftheswitchgearismorethan10sets,theinstallationshouldbestartedfromthemiddle.Firstofall,putthe2setsofmiddleswitchgearproperly,movetheswitchgearontothefoundationframeworkand foundationframework.Then2setsofswitchgearareassembledtogether.Theassemblingproceduresareas开关柜拼接前应卸下开关柜顶部的4只及其固定下右侧板后的10只拼柜用的拉铆螺母都在出厂前准Beforetheswitchgearisassembled,4liftinglugsandsetscrewsonthetopoftheswitchgearshouldberemoved.Beforetheswitchgearisassembled,checkandseewhetherthepartitionormoundlayerinthebus-barroomandthepartitionintheliftingswitchgearhavebeeninstalledcorrectly.Theassemblingworkistoconnectthe2setsofswitchgeartogetherwith10M10*35hexagonsocketscrews.10rivetnutstoconnectthe2setsofswitchgeartogetherarereadybeforetheswitchgearleavesthefactory.Theswitchgearonlyneedstobealignedwheninstallation.Fromtheleftoftheswitchgear,screwtheboltstoconnectthe2setsofswitchgeartogethertothecorrespondingrivetnuts.Firstofall,put10boltsince,screwthemwiththehands,andthentightenthemonebyonewithawrench.ThisoperationisveryRepeattheaboveprocedures.Assembletheswitchgearonebyonetogether.Finallyinstallthebackcover-teandcable-trenchcover-teproperly.(五)母线的安装联接Bus-barFortheswitchgearwiththebus-barpartition,thebushingshallbeinstalled.Thebus-barshallbecleanedwiththecleananddrysoftcloth.Checkandseewhetherthereisinsulationdamage.Removethegreaseandadhesivedirt. Beforethebus-barisinstalled,allkindsofaccessoriesrequiredtoinstallthebus-barshouldbechecked,includingtherectanglebus-bar,M10socketheadcapscrews,bellevillespringgaskets,nuts,endsupportframeandinsulatingcover.Pleasenotethatwhentheswitchgearwiththedifferentwidthisassembled,thelengthof3-phasebus-barisdifferent.Whenthebus-barischecked,takecareBeforethemainbus-barisinstalled,thepressurerelieftesatthetopoftheswitchgearshouldberemoved.Thesepressurerelieftesandscrewsshouldbekept分支母线与主母线的联接采用四只不低于8.8-46-46Connectthebranchbus-barwiththemainbus-barwith4M10hexagonhigh-strengthboltswithlevelofnolowerthan8.8.BothendsofM10hexagonhigh-strengthboltsmustbeputwiththebellevillespringgaskets.NotethattheopeningsofM10hexagonhigh-strengthboltsmustfacetheconductivebody.Connectthegroundingwireofthegroundingswitchwiththegroundingwireoftheswitchgear.--PAGE481.Mainbus-bar 2.Branchbus-bar3.Bolt 4.Cushion 5.L-typeheat-shrinkabletubing heat-shrinkabletubing 7.T-typeheat-shrinkableFigure3:Connectiontypebetweenthebus-barandbranchbus-bar;Usageofreducingheat-shrinkabletubing50.米。建议每只螺栓用扭力扳手检查后应作Generallytheswitchgearbeginstobeinstalledfromthemiddleandconnectedone-by-onetowardbothends.Firstofall,thelowest-phasebus-barisfittedone-by-oneaccordingtothebus-barorder.Thebolts,gasketsandnutsareallinstalledproperlyandtightenthembyhand.Afterthebus-barisinstalledince,tighteneachboltbyuseofsocketspannerandtorquewrenchinorder.Thetighteningtorqueofthemainbus-barboltis50N/meter.Itis mendedthateachboltshouldbetightenedafterbeingcheckedwiththetorquewrenchinordertoavoidtheomission.Itshouldbetightenedonthebus-barterminalortheboltingsupportte(supporttheinsulationcover).Aftertheboltforthebus-baristightened,installtheinsulationcover.Usethesamemethodtoinstalltheintermediatephasebus-barandthehighestphasebus-bar,andfinallyinstallthepressurereliefte. correspondingassemblydrawingsandpartslist.(六)电力电缆和控制电缆的联接Connectionofpowercableandcontrolcable of -49-49 Leadinthepowercableandstripoffthecableatthepredeterminedlength.按制造厂的说明书安装电缆终端,注意保护绝缘层,不得将其Installthecableterminalaccordingtomanufacturer'smanual.Notethattheinsulationlayermustbeprotectedandtheinsulationlayermustnotbedamaged.Thecorresponding-sizeholeonthedamringmustbepunchedaccordingtothecable-corediameter.Passthecablethroughthebase-teandthedamringandconnectthecabletotheterminals,puttheheatshrinkabletubingontothecableandconnectthecabletotheconnectingpoint.Thecableshouldbe--PAGE52fixedHeattheheatshrinkabletubingandmaketheheatshrinkabletubingentirelycovertheexposedpartoftheInstallthebase-te,covertightlythedamringandclampthecablewiththecableclamps.将控制电缆送进左侧控制线槽(Leadthecontrolcableintotheleft-sidecable-trench(Fig:5/2)架向上旋转,把控制电缆芯引入仪表室D内。Stripoffthecabletubingandfixthecableontothetopofthecable-trench.Rotateuptheterminalframeandleadthecontrol-cablecoreintothecontrolroomD.Connectthecontrolcablestothecorrespondingterminalsaccordingtothewiringdiagram. (七)接地铜排的联接Connection 接母线。开关柜出厂时已把用来互连的短的联接排卸下,穿越柜间预留的长,固定在相邻两柜的主接地铜排上。开关柜接母线与配电室接地网的 switchgeartogethertoformaunifiedgroundingbus-bar.Whentheswitchgearleavesthefactory,ashortconnectingcopper-barusedtointerconnecthasbeentemporarilyfixedontotherightsideofthemaingroundingcopper-bar.Wheninstalling,removetheinterconnectedcopper-bar,leadtheinterconnectedcopper-barthroughtherectangularholeontheswitchgearandfixitonthemaingroundingcopper-barof copper-baroftheswitchgearcanbeconnectedwiththesubstationgroundinggridbyuseoftheconnectingcable.Thegroundingcableisledinfromthe holeoftheswitchgear.Thegroundingcableisconnectedtothegroundingcopper-barbyuseoftheterminal.(八)安装工作的收尾FinalworkofCheckandseewhethertheswitchgearpaintisdamaged.Ifany,repair.Checkandseewhetherthebolts,especiallytheboltsforthenewly-installedbus-barandgroundingsystem,aretightenedornot.CleantheswitchgearReinstallthecoverteremovedduringthe将断路器手车插入开关柜。Insertthecircuit-breakerhandcartintotheswitchgear.检查触子和联锁机构是否灵活,在需要的地方重新上IsoflexTopesNB52润滑剂。-53-53Checkandseewhethertheisolatedcontactandinterlockingmechanismareflexible.RefillIsoflexTopesNB52lubricantifnecessary.六、开关柜的运行OperationofTherelatedworkandoperatingprocedurescanonlybecarriedoutbythewell-trainedelectricaltechnicians.Theyarefamiliarwiththeswitchgear,GB&IECstandardsandsafetyprocedures,workingregulationsandmanualspecifiedbythespecializedagenciesandlocalBeforethehighvoltagepowersupplyisturnedon,thefollowingworkshouldbecompleted:应认真核对开关柜铭牌所标技术数据与运行电力--PAGE55Checkcarefullyandseewhetherthetechnicaldataontheswitchgearnameteisconsistentwiththetechnicaldatarequiredbythepowerline;Checkthecomponentssuchascircuitbreaker,movableunitandinsulatingparts;检查主接地母线和柜外变电站接地导体的联接是Checkandseewhetherthemaingroundingbus-barandthesubstationgroundingconductorareconnected7.3节的指Checkandseewhetherthepaintsurfaceisdamaged.Ifany,repairaccordingtotheguidanceofsection7.3.Removealltheremainingmaterials,irrelevantobjectsandtoolsintheswitchgear.Withclean,dryandsoftclothtoCleantheinsulatingpartsandsealingstripsontheswitchgeardoorwiththeclean,dryandsoftclothes.Cleantheadhesivedustandgreaseaccordingtotheguidance.Reinstallthecoverteremovedduringinstallation,wiringandtest.Checkandseewhetherthepole-rodcoverofthecircuitbreaker(Forthelargecurrentcircuitbreaker,itisnotinstalled)isinstalledcorrectly.卸掉断路器极柱上的盖(当贴有此指示标志Removethepole-rodcoverofthecircuitbreaker(whenthisindicationsignispostedup).IEC298GB3906进行回路工频耐Ifnecessary,carryoutthecircuitpowerfrequencywithstandvoltagetestaccordingtoIEC298orGB3906.Payspecialattentiontothevoltagetransformerandcableinth

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论