版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
精选优质文档-----倾情为你奉上/r/n精选优质文档-----倾情为你奉上/r/n专心---专注---专业/r/n专心---专注---专业/r/n精选优质文档-----倾情为你奉上/r/n专心---专注---专业/r/nICS/r/n /r/nFORMTEXT/r/n点击此处添加ICS号/r/nFORMTEXT/r/n点击此处添加中国标准文献分类号/r/nFORMTEXT/r/nDB/r/nFORMTEXT/r/n1/r/n1/r/nDB/r/nFORMTEXT/r/n11/r/n//r/nFORMTEXT/r/nT/r/nXXXX/r/n—/r/nFORMTEXT/r/nXXXX/r/nFORMTEXT/r/nFORMTEXT/r/n数据中心节能监测/r/nFORMTEXT/r/nMonitoringandtestingforenergysavingofdatacenter/r/nFORMTEXT/r/n点击此处添加与国际标准一致性程度的标识/r/nFORMDROPDOWN/r/nFORMTEXT/r/nFORMTEXT/r/n /r/n/r/n-/r/n/r/nFORMTEXT/r/nXX/r/n/r/n-/r/n/r/nFORMTEXT/r/nXX/r/n发布/r/nFORMTEXT/r/nXXXX/r/n/r/n-/r/n/r/nFORMTEXT/r/nXX/r/n/r/n-/r/n/r/nFORMTEXT/r/nXX/r/n实施/r/nFORMTEXT/r/n北京市质量技术监督局/r/n /r/n发布/r/n目次/r/n/r/n前/r/n /r/n言/r/n本标准按照GB/T1.1-2009中给出的规则起草。/r/n本标准由北京市发展和改革委员会提出并归口。/r/n本标准由北京市发展和改革委员会组织实施。/r/n本标准起草单位:中国建筑科学研究院、北京科技大学、中国建筑技术集团有限公司、中国移动北京公司、中能深思(北京)节能技术有限公司。/r/n本标准主要起草人:于震、吴延鹏、李怀、崔向红。/r/n数/r/n据中心节能监测/r/n范围/r/n本标准规定了北京市行政辖区内数据中心节能监测项目、监测方法、计算方法、评价指标和监测结果评价。/r/n本标准适用于北京市用能单位所属数据中心的节能监测。/r/n规范性引用文件/r/n下列文件对于本文件的应用是必不可少的。凡是注日期的引用文件,仅注日期的版本适用于本文件。凡是不注日期的引用文件,其最新版本(包括所有的修改单)适用于本文件。/r/nGB/T2589综合能耗计算通则/r/nGB15316节能监测技术通则/r/nGB17167用能单位能源计量器具配备和管理通则/r/nGB50174数据中心设计规范/r/n术语和定义/r/n下列术语和定义适用于本文件。/r/n数据中心datacenter/r/n拥有宽带出口,为用户的服务器、网络设备等互联网相关设备提供放置、代理维护、系统配置及管理服务,或提供计算、存储、软件等资源的服务和其他应用服务的电子信息系统机房。/r/n信息设备informationequipment/r/n指部署在数据中心内用于数据信息计算、处理、存储、传输、交换的计算机设备、网络设备、服务器设备、存储设备等。/r/n信息设备负荷使用率informationequipmentloadrate/r/n数据中心信息设备实际用电负荷与数据中心信息设备设计用电负荷之比。/r/n电能使用效率powerusageeffectiveness(PUE)/r/n同一时间周期内,数据中心总电能消耗量与信息设备电能消耗量之比。/r/n能源使用效率energyusageeffectiveness(EUE)/r/n同一时间周期内,数据中心总能源消耗量与信息设备能源消耗量之比。/r/n监测项目/r/n检查项目/r/n检查项目包括:/r/n是否建立完善的能源管理规章制度(如岗位责任、部门职责分工、人员培训、能耗定额管理、奖惩制度等);/r/n能源计量器具配备率和准确度等级是否符合/r/nGB17167/r/n的相关规定;/r/n能源记录台账,统计报表是否真实、完整、规范;/r/n能源技术档案(配电及计量系统图纸、计量器具台账、计量系统软件使用说明书等);/r/n能耗数据定期统计分析结果。/r/n测试项目/r/n测试项目包括:/r/n环境参数(室内空气温度、相对湿度);/r/n测量点电能;/r/n测量点其他用能量。/r/n监测方法/r/n基本要求/r/n节能监测应在数据中心运行工况稳定条件下进行。/r/n数据中心机房专用空调设备连续运行24小时以上。/r/n使用固定计量仪表,对数据中心能耗进行持续的测量和记录。/r/n计量仪表/r/n所用仪表应满足测试项目的要求,并在检定/校准合格周期内。/r/n测量温度、相对湿度的仪表准确度等级不应低于0.5级。/r/n节能监测过程中采用准确度等级为1.0级的电能计量仪表,并应具数据输出接口,不应与供电部门计量仪表共用互感器,不应与计费电能表串接。/r/n计量天然气的仪表准确度等级不应低于2.0级,计量冷量的仪表准确度等级不应低于2.0级。/r/n测试方法/r/n环境参数/r/n测点布置/r/n主机房面积不大于100m/r/n2/r/n时,平均分布6个测点,每增加10m/r/n2/r/n应增加1个测点,总测量点不超过50个。测点距地面选取0.8m和2.2m两个高度,距墙不应小于0.6m,并应避开送风口。/r/n测量方法/r/n环境参数测量步骤如下:/r/n根据数据中心的实际情况,按5.3.1.1的要求选定测量点。/r/n在选定的测量点安装符合5.2要求的计量仪表。/r/n使用计量仪表在节能监测时进行现场测试,测试时间不少于30min,每15min记录一次。/r/n运行能效/r/n监测范围/r/n按照GB50174规定的主机房、支持区和辅助区,不包括行政管理区。/r/n测量点位置/r/n数据中心应至少在以下位置安装设置计量仪表或选为测量点。/r/n数据中心总市电消耗的测量位置应为变压器低压侧(见图1中的A点)。/r/n数据中心信息设备电能消耗的测量位置应为UPS输出端供电回路(见图1中的B点)。/r/n数据中心设有柴油发电机、可再生能源,或采用集中供冷时,所有柴油发电机馈电回路的电能(见图1中A1点的测量值)、可再生能源供电的电能(见图1中A2点的测量值)、集中供冷能源消耗量(见图1中A3点的测量值)应计入总能源消耗量中,对于采用冷热电联产的数据中心,应计量天然气的消耗量以及产热量和产冷量。/r/n对能耗监测要求较高的数据中心,宜采用对各主要系统的能耗分别计量的方法(见图1中的E1点、E2点、E3点、E4点的测量值)。图1中的/r/n“/r/n其他系统/r/n”/r/n能耗主要指的是室外照明、办公区能耗等非数据中心能耗。/r/n数据中心能耗测量点位置图/r/n测量方法/r/n运行能效测量步骤如下:/r/n以北京市年平均室外温度12.5/r/n℃/r/n为基准,上下3.5/r/n℃/r/n的范围即室外温度介于/r/n9-16/r/n℃/r/n时进行运行能效监测。/r/n根据数据中心的实际情况,按5.3.2.2的要求选定测量点。/r/n在选定的测量点安装符合5.2要求的计量仪表。/r/n对数据中心的各系统能耗进行周期为24小时的不间断测量,并记录能耗数据。/r/n计算方法/r/n环境参数/r/n数据中心平均温度、平均相对湿度按公式(1)、(2)计算:/r/n /r/n (/r/nSEQ标准自动公式\*ARABIC/r/n1/r/n)/r/n /r/n (/r/nSEQ标准自动公式\*ARABIC/r/n2/r/n)/r/n式中:/r/n—/r/n室内空气平均温度(/r/n℃/r/n);/r/n—/r/n各测量点室内空气温度(/r/n℃/r/n);/r/n—/r/n平均相对湿度(%);/r/n—/r/n各测量点相对湿度(%);/r/n—/r/n测量点数。/r/n电能使用效率(PUE)/r/n电能使用效率实测值的计算/r/n电能使用效率实测值按公式(3)计算:/r/n /r/n (/r/nSEQ标准自动公式\*ARABIC/r/n3/r/n)/r/n式中:/r/n—/r/n数据中心电能使用效率实测值;/r/n—/r/n数据中心监测时间段内电能消耗,即图1中A点计量数据,kWh;/r/n—/r/n数据中心监测时间段内信息设备电能消耗,即图1中B点计量数据,kWh。/r/n电能使用效率调整值的计算/r/nPUE的调整值是根据影响数据中心的PUE的因素(包括数据中心分级、空调制冷形式和信息设备负荷使用率)的不同而制定的用于平衡上述因素差异的调整值,差异因素及其对应调整值见表1。/r/nPUE调整值/r/n调整因素/r/n压缩机/r/n调整值/r/n加湿/r/n调整值/r/n新风/r/n调整值/r/nUPS/r/n调整值/r/n供电/r/n调整值/r/n照明/r/n调整值/r/n其他/r/n调整值/r/n单一条件变化的PUE调整值/r/n数据中心分级/r/nA级/r/n0/r/n0/r/n0.02/r/n0.06/r/n0/r/n0/r/n0.02/r/n0.1/r/nB级/r/n0/r/n0/r/n0/r/n0/r/n0/r/n0/r/n0/r/n0/r/nC级/r/n0/r/n-0.04/r/n-0.08/r/n-0.016/r/n-0.004/r/n0/r/n-0.01/r/n-0.15/r/n制冷形式/r/n水冷/r/n-0.11/r/n0/r/n0/r/n0/r/n0/r/n-0.11/r/n风冷/r/n0/r/n0/r/n0/r/n0/r/n0/r/n0/r/n其他/r/n0/r/n0/r/n0/r/n0/r/n0/r/n0/r/n信息/r/n设备负荷使用率/r/n25%/r/n0/r/n0.18/r/n0.38/r/n0.7/r/n0.06/r/n0.06/r/n0.06/r/n1.44/r/n50%/r/n0/r/n0.06/r/n0.1/r/n0.22/r/n0.02/r/n0.02/r/n0.02/r/n0.44/r/n75%/r/n0/r/n0.02/r/n0.03/r/n0.09/r/n0.007/r/n0.007/r/n0.007/r/n0.161/r/n100%/r/n0/r/n0/r/n0/r/n0/r/n0/r/n0/r/n0/r/n0/r/n注:按照GB50174划分数据中心A、B、C级。/r/n根据数据中心分级、空调制冷形式、信息设备负荷使用率等分类类型在表1中查找对应的单一条件变化的PUE调整值。调整值可以选择性使用,在计算时根据实际情况进行选择,如对其中的一项不予以考虑等。对于信息设备负荷使用率大于或等于25%的数据中心,其调整值根据表1中对应的单一条件变化的PUE调整值进行等比例差值计算而得。对于信息设备负荷使用率小于25%的数据中心,其调整值直接使用表1中25%对应的单一条件变化的PUE调整值。/r/n示例:某北京市数据中心等级为A级,采用水冷制冷形式,信息设备负荷使用率为50%,则其单一条件变化的PUE调整值分别为:0.1,-0.11,0.44。/r/n电能使用效率修正值的计算/r/n电能使用效率修正值按公式(4)计算:/r/n /r/n (/r/nSEQ标准自动公式\*ARABIC/r/n4/r/n)/r/n式中:/r/n—/r/n数据中心电能使用效率修正值;/r/n—/r/n数据中心电能使用效率调整值。/r/n在后文中,如无特别说明,PUE/r/ncor/r/n用PUE来代替。/r/n能源使用效率(EUE)/r/n能源使用效率实测值的计算/r/n能源使用效率实测值按公式(5)计算:/r/n /r/n (/r/nSEQ标准自动公式\*ARABIC/r/n5/r/n)/r/n式中:/r/n—/r/n数据中心监测时间段内总能源消耗,即图1中A+A1+A3点计量数据,kgce/kg;/r/n—/r/n数据中心/r/n监测时间段内信息/r/n设备能源消耗,/r/n即/r/n图/r/n1中B点/r/n计量数据,kgce/kg。/r/n数据中心各种能源转换成标煤,其转换参考本标准附录B规定执行;/r/n数据中心非电力能源消耗量按照GB/T2589计算,电力能源消耗量按照等价值计算;/r/n若采用天然气驱动的冷热电联产系统,用于向数据中心供冷、供热和供电的天然气消耗应计入/r/nP/r/nTotal/r/n。/r/n能源使用效率调整值的计算/r/n能源使用效率调整的计算与电能使用效率调整值的计算相同,按6.2.2方法计算。/r/n能源使用效率修正值的计算/r/n能源使用效率修正值按公式(6)计算:/r/n /r/n (/r/nSEQ标准自动公式\*ARABIC/r/n6/r/n)/r/n在后文中,如无特别说明,/r/nEUE/r/ncor/r/n用EUE来代替/r/n。/r/n评价指标/r/n环境参数指标/r/n数据中心环境参数评价指标见表2。/r/n数据中心环境参数评价指标/r/n数据中心环境参数允许值/r/n主机房环境温度/r/n18/r/n—/r/n27/r/n℃/r/n主机房相对湿度/r/n40/r/n—/r/n60%/r/n将平均温度与平均相对湿度与上述机房环境温度、相对湿度检测指标进行比对,不满足指标要求的判定为不合格。/r/nPUE指标/r/n数据中心PUE评价指标见表3。/r/n数据中心PUE指标/r/n类型/r/n大型数据中心/r/n中、小型数据中心/r/n数据中心PUE指标/r/n≤/r/n1.8/r/n≤/r/n2/r/n./r/n0/r/n机房建筑面积(IDC数据机房面积,不包含供电系统、空调系统等配套用房面积)一般在5000m/r/n2/r/n以上(含)或信息设备总功率在6000kW以上(含)的数据中心为大型数据中心,其余数据中心为中小型数据中心。/r/n信息/r/n设备/r/n总功率/r/n指其/r/n实际运行/r/n功率。/r/nEUE指标/r/nEUE是评价数据中心能源效率的指标,与数据中心PUE的评价指标相同。/r/n监测结果评价/r/n本标准规定的数据中心节能监测考核指标是监测合格的最低标准。/r/n监测单位应出具《数据中心节能监测报告》,见附录A中的表A.1,并依据本标准作出合格或不合格的评价。/r/n/r/n对于监测不合格的数据中心,监测单位应提出改进建议,使用单位应采取相应措施对数据中心进行整改。/r/n
/r/n(规范性附录)
数据中心节能监测报告/r/n表A.1/r/n数据中心节能监测报告/r/n报告编号:/r/n/r/n/r/n委托单位/r/n监测日期/r/n被监测单位/r/n监测依据/r/n监测地点/r/n数据中心基本信息/r/n数据中心规模/r/n□/r/n大型/r/n/r/n/r/n□/r/n中小型/r/n数据中心等级/r/n□/r/nA级/r/n□/r/nB级/r/n□/r/nC级/r/n信息设备负荷使用率/r/n%/r/n制冷形式/r/n□/r/n风冷/r/n□/r/n水冷/r/n□/r/n其他/r/nPUE调整值/r/n检查项目/r/n序号/r/n检查项目/r/n检查结果/r/n1/r/n数据中心是否建立完善的能源规章制度/r/n2/r/n能源计量器具配备率和准确度等级是否符合GB17167的相关规定/r/n3/r/n能源记录台账、统计报表是否真实、完整、规范/r/n4/r/n能源技术档案是否完整、规范/r/n7/r/n是否对能耗数据进行定期的统计分析/r/n测试项目/r/n序号/r/n监测测试项目/r/n单位/r/n测试结果/r/n评价指标/r/n结果评价/r/n1/r/n数据中心环境温度/r/n℃/r/n2/r/n数据中心相对湿度/r/n%/r/n3/r/n数据中心电能使用效率PUE值/r/n1/r/n4/r/n数据中心能源使用效率EUE值/r/n1/r/n监测结果评价及改进建议:/r/n监测单位:(盖章)/r/n年月日/r/n编制:审核:
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 电力设备供应招标合同三篇
- 珠江花园房屋买卖合同三篇
- 人力资源招聘计划
- 《黄金与美元的对决》课件
- 《鱼苗繁育技术》课件
- 《酒店销售技巧培训》课件
- 医院消毒灭菌课件
- 《使用框架设计网》课件
- 组织胚胎学课件结缔组织
- 新能源建模报告范文
- 2021年商丘市第一人民医院医护人员招聘笔试试题及答案解析
- 中职餐饮服务与管理-完整版PPT课件中职全套教程
- 小学信息技术 甘教版 四年级上册 认识计算机 课件
- 泼水节卡通儿童教学课件PPT模板
- MBA数据模型与决策考卷及答案
- 智能控制技术专业申报材料
- 大气污染控制工程课程设计说明书(附图纸)
- 正丁烷的理化性质及危险特性表
- DB36T 1477-2021碳普惠平台运营管理规范
- 日光温室的设计与建造
- 心衰病住院临床路径
评论
0/150
提交评论