1、Determining the value to be set for $CURR_MON with external axesBackground:If the value of $CURR_MON is set too low, acknowledgement message 1241 is generated:ixt monitoring, current limit of the motor cable E1 after 60 s exceeded 100%In such a case, the current r.m.s. value must be calculated from

2、the complete program cycle time (incl. wait times). The oscilloscope trace function is used for this. Holding currentREAL $CURR_MON12;PERMISSIBLE HOLDING CURRENT DEFINES THE LIMIT FOR THE I2t MONITORING AT 55 C (CABLE WARMING!)$CURR_MON1=7.3$CURR_MON2=7.3$CURR_MON3=2.7$CURR_MON4=2.0$CURR_MON5=2.0$CU

3、RR_MON6=2.0$CURR_MON7=9.3$CURR_MON8=12.8$CURR_MON9=6.7$CURR_MON10=0.0$CURR_MON11=0.0$CURR_MON12=0.0Permissible limits:Peak current: 2 sHolding current:60 sMotor I0 (r.m.s.)KK67Y26.9 AKK65Y19.7 A1FK610012.8 A1FK6081 6.7 AKK53Y 6.7 AKK55Y12.8 AKK4EY 2.7 AMotor typeA0ABCCC0D1FK7060 2.7 AD01FK7032 1.7 A

4、1FK7034 2.0 A1FK7081 9.3 AEE0HProcedureMethod:The system executes complete production cycles (incl. wait times) until a minimum time of 60 seconds has elapsed. During this time, the current of the axis concerned is recorded in the trace.The value of $CURR_MON for the relevant axis is to be set to a

5、higher value, than the determined r.m.s. value.Test programData list for test programAutomatic start of the oscilloscope function by means of program commandsStart of the recordingAutomatic adaptation of the nameAutomatic end of the recordingEnd of the trace recordingSettings for the oscilloscope tr

6、ace function (1)Settings for the oscilloscope trace function (2)Trace recording the current over 6 cycles in 90 sSelection of the area for calculation of the r.m.s. valueDisplay of the r.m.s. valuer.m.s. value: 4.78 from 11.70 to 89.99 sRMS (effective value: 4.78 von 11.7 bis 89.99)Trace settings fo

7、r axis E1 (1)Monitor Diagnosis Oscilloscope ConfigureAssign name to traceEnterTrace length min. 60 sEnterEnterUse the UP and DOWN arrow keys to select the trigger condition Trigger on motion startDeactivate the NUM functionPress TAB to access the DSE cardUse the UP and DOWN arrow keys to select DSE

8、2Press TAB to access the I/O groupUse the UP and DOWN arrow keys to select No I/O dataSoftkey DSE Tab.Trace settings for axis E1 (2)Use the UP and DOWN arrow keys to position the cursor on the actual current of axis E1Mark this by pressing the space barSoftkey MainSoftkey SavePress softkey Start unt

9、il the trace status #T_WAIT is displayedRun programWait until trace status #T_END is displayedSoftkey ShowSoftkey InfoCurves that are not required can be removed from the display by pressing the Enter keySoftkey Info only the current curve is visibleRepeatedly press the softkey until the softkey RMS appearsPress the softkey RMSTrace settings for axis E1 (3)Use the left arrow key to mark the start of the area for which evaluation is to be carried outEnterUse the right arrow key to mark the end of the area for which evaluation is to be carried outEnterThe r.m.s.

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论