




版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1、Good is good, but better carries it.精益求精,善益求善。ng丁山宾馆商务会所施工方案ng丁山宾馆商务会所施工方案ng丁山宾馆商务会所施工方案 PAGE institutes, lawyers and practitioners or institutions. Second, business loan customers: with a focus on marketing performance good, higher market share and business in line with the national policy support,
2、 better prospects and the operating time in a year (or more) business owners. 3. definitions, abbreviations and classifications 3.1 definitionPAGE PAGE 119institutes, lawyers and practitioners or institutions. Second, business loan customers: with a focus on marketing performance good, higher market
3、 share and business in line with the national policy support, better prospects and the operating time in a year (or more) business owners. 3. definitions, abbreviations and classifications 3.1 definitionPAGE 119ng丁山宾馆商务会所施工方案 PAGE institutes, lawyers and practitioners or institutions. Second, busine
4、ss loan customers: with a focus on marketing performance good, higher market share and business in line with the national policy support, better prospects and the operating time in a year (or more) business owners. 3. definitions, abbreviations and classifications 3.1 definition一、编制依据1、丁山宾馆商务会馆工程施工图
5、。2、国家现行的建筑工程施工规范、施工图集、施工操作规程和建筑工程施工质量验收统一标准。3、国务院建设部和江苏省有关建设工程质量、安全、文明施工的法律、法规、条例、规定和相关文件,以及地方相应的规定。4、本项目施工所在地的气象、地形及周边外部条件调查情况。5、公司内部质量、安全、健康、环保体系文件和有关管理文件。二、工程概况丁山宾馆商务会馆工程,位于南京市察哈尔路与戴家巷交汇处,位置处于山坡上在丁山花园大酒店的东北方位,具体见建筑施工总平面布置图,东侧山坡下为6层住宅小区;建筑面积为1650平方米;地下一层,地上二层,地下一层层高4.20米,地上一层层高5.00米, 地上二层层高3.60米,建
6、筑总高度为8.60米;0.000相当于绝对标高38.60米。该工程为框架结构;工程耐火等级为二级,地下部分为一级;抗震设防烈度为7度,建筑的抗震设防类别为丙类;结构设计使用年限为50年;地下一层为休闲娱乐和服务用房,地上一层为接见厅和宴会厅,地上二层为客房;屋面两道防水设防;抗震设防等级为六度。地下室筏板基础底板厚为300,钢筋混凝土剪力墙外墙厚300;底板、剪力墙及顶板均采用C30S6抗渗混凝土浇筑;0.000以上的结构砼标号均为C30。三、工程实施目标1、质量承诺各分部分项工程一次性交验合格率达到100%,争创南京市优质工程。2、工期承诺计划开工日期为2009年4月1日,确保2009年9月
7、30日竣工交付。3、安全生产目标本工程在整个施工过程中将轻伤事故控制在1.5以内,重伤事故及重大亡人事故控制为零。4、现场文明管理目标力争达到江苏省安全文明工地。5、新技术、新工艺应用目标为了实现上述的质量、工期施工目标,根据本工程的具体特点,在施工过程中尽可能的采用新技术、新工艺,力争取得最大的综合效益。6、服务目标信守合同,协调好各方面关系,接受建设单位、政府部门、监理公司等单位对本工程的质量、工程进度、计划协调、现场管理、安全文明施工、成本管理等的控制和监督。工程竣工验收后,及时给建设单位签发建设工程质量保修书,并写清联系人和电话号码,竣工后36个月内现场设专人值班24小时保修服务,保修
8、期内随叫随到。四、施工部署施工部署是指导工程全过程施工的纲领性文件,明确了指导整个施工的原则性条款。在综合分析了工程特点、设计意图、建设地区实际情况、业主意向及我公司实力等因素后,对本工程进行了科学合理的安排,寻求技术、资金和社会信誉的最佳结合点,以下对施工组织、施工准备、施工工艺流程等进行了明确,使今后施工处于全面受控状态,以便更好地完成本工程的施工任务。1、施工组织安排本工程实行项目经理负责制,项目经理对工程统筹决策,全面负责,确保工程质量、安全和文明施工。努力缩短工期,强化成本核算。项目经理部设专人负责生产、技术、质量、材料供应、安全文明、环保的现场管理、质量监督以及安全保卫等工作。配备
9、足够的各专业工种的施工熟练工和管理骨干,精心组织施工。2、管理协调组织项目部将指定专人负责施工过程管理部门中的对外协调工作,并作为项目的重点工作来抓,落实责任到部门、人员。主动与地方政府行政管理部门,基础设施(道路交通、水、电等)配置管理部门,以及质量监督管理,安全生产监督管理,工程试验检测中心,建设银行等部门联系,在业主和监理的指导帮助下,建立“政府、建设单位,设计单位,监理单位,施工单位”五方正常的,健康的,良性的工作渠道,以确保本项目能按照业主意思,顺利地施工、竣工并投入使用,达到我公司对业主承诺的各项施工合同指标。3、项目部组织机构技术负责人项 目 经 理项目副经理施工员预算员质检员
10、材料员资料员试验员计量员设备员保管员安全员4、项目部主要管理人员岗位职责项目经理岗位职责认真贯彻执行公司的质量、安全、环保工作方针、目标及公司的有关规定。参与合同评审,执行合同条款,确保项目达到合同的工期、质量要求。建立和完善项目部组织机构,明确各类人员职责并对其进行考核。主持项目部工作,对项目施工全面负责。负责质量、安全、环保策划活动的具体实施。参与工程专业分包方、劳务分包方的评价和管理。参与分部、单位工程质量检验评定工作,参与竣工验收和服务。项目技术负责人及项目副经理岗位职责1)项目技术负责人岗位职责认真贯彻执行公司的质量方针、目标。负责本项目施工技术、质量、安全和环保管理工作。严格执行国
11、家颁发的有关规范、标准规程及地方规定、标准,按图施工,加强施工图、标准及有关技术资料的管理。熟悉设计意图,参加图纸会审、设计交底和安全生产技术交底,做好图纸会审记录汇总,负责设计变更的施工资料签发。深入调查研究,一般工程技术问题在自己职责范围内,自行解决;对重大技术问题及时汇报公司和监理公司;参加中间及竣工验收。组织学习各项技术标准、技术规范、规程和技术管理制度,积极推广“三新”应用。负责纠正和预防措施的实施。组织收集质量信息,按不合格品的严重程度分别向有关部门传递。制定与编制项目部需要收集的本工程质量记录清单。负责质量控制点,特殊过程以及分部工程的技术交底和安全交底。组织定期检查工程质量,落
12、实“三检”制度的实施与检查其记录。2)项目副经理岗位职责认真贯彻执行公司的质量方针、目标及分公司的有关规定。执行合同条款,确保项目达到合同的工期、质量要求。参与建立和完善项目部组织机构,明确各类人员职责并参与对其进行考核。主持项目部施工生产及安全工作,对项目施工日常工作负责。负责质量策划活动的实施。参与工程专业分包方、劳务分包方的评价和管理。参与分部、单位工程质量检验评定工作,参与竣工验收和服务。项目施工员岗位职责认真贯彻执行本公司质量方针、目标和质量体系文件。认真审阅图纸,弄清设计意图,参加图纸会审。依据图纸尺寸做好测量、定位、放线工作。做好分项工程及关键部位的技术交底,督促施工班组贯彻执行
13、。组织隐蔽工程验收,做好施工日记和隐蔽工程验收记录。协助项目质检员、资料员、安全员等做好相关技术管理工作,对施工中发现的问题及时上报。及时收集、传递施工信息,及时解决施工中存在的问题。及时落实监理的指令,及时填写申报单和监理验收的签证。项目质检员岗位职责贯彻执行公司的质量方针、目标和质量体系文件。负责工程项目的施工质量监督管理,严格按照现行国家质量标准对工程施工质量的评定。参加工程的图纸会审、技术交底,熟知施工过程和施工技术措施。参加进货检验、过程检验和材料的二次复检,并对过程检验作出标识。参加隐蔽工程验收、中间验收和单位工程的竣工交付。对返工、返修的产品进行复检。及时反馈施工信息。项目统计资
14、料员岗位职责贯彻执行本公司的质量方针、目标和质量体系文件。按当地要求收集、整理好工程技术档案资料,做到准确、完整、字迹工整。负责收集原材料、砂浆、混凝土及焊接件构件的试验、抽验记录和检验评定记录。参加工程图纸会审,做好设计变更登记、传递工作,全面地收集分部、分项工程隐蔽验收记录。协助项目技术负责人做好质量信息的收集整理工作。工程开工前到竣工后,及时收集整理好工程竣工资料及竣工图,确保资料、图纸齐全、准确,并按规定保存、送档。及时报送各类统计报表。项目预核算员岗位职责贯彻执行公司质量方针、目标及质量体系文件。贯彻执行国家或地方预算定额、施工定额的有关现行规定。参加图纸会审,及时收集设计变更文件和
15、业主监理指令的变更手续。了解工程的施工条件、方法及前后工序情况,以施工图和施工组织设计为依据编制施工预算和决算。编制工程物资需求计划。项目材料员岗位职责贯彻执行公司质量方针、目标及质量体系文件。根据项目需要及时编制项目物资采购计划。根据工程进度按期组织材料进场,并协助项目保管员对顾客提供的物资进行验收。 材料员对所供物资要督促货主或厂家提供样品及合格证等,并负责按样品提货。不合格品负责退货。每月月底前上报材料采购供需情况报表给总采购员,按照公司物资管理工作程序,对物资采购工作组织实施,确保进场物资合格。对进场的物资验收、保管,及时作出标识,收集标牌与合格证,并作规格、进货量、批次、日期等记录。
16、项目安全员岗位职责贯彻执行公司质量方针、目标及质量体系文件。负责本项目施工安全生产,落实安全责任的教育、考试、考核与责任书签定。严格按国家现行安全规范及有关操作规程对工程项目进行安全检查。参加编制安全技术措施与安全交底,并认真督促实施,经常对职工进行现场安全教育。定期组织各专业工种负责人进行安全大检查,落实整改措施与复查。项目设备管理员岗位职责贯彻执行公司质量方针、目标及质量体系文件。组织专业人员安装机械设备,配合有关部门对机械设备进行验收、挂牌,并对项目上的施工机械设备进行全面管理。对机械设备的运行、使用、维护、保养进行监督,并做好记录。参加项目部机械设备事故的调查与处理,在24小时内写出有
17、关书面调查报告。对设备作出标识,并协助当地安全部门对设备的检查及管理。项目试验员岗位职责贯彻执行公司质量方针、目标及质量体系文件。严格按国家现行关于材料检(试)验标准、方法和技术规定要求,负责项目原材料、砂浆、砼及构件抽验、复检工作,并将检验信息向有关部门传递,有质量问题,及时向项目施工员及技术负责人汇报。收集整理检验和试验报告单,并保存好。对各种原材料、检验试件,按检验、试验结果作出标识,会同保管员作标识的复核与管理。项目计量员岗位职责贯彻执行公司的质量方针、目标及质量体系程序文件。建立本项目部的检验、试验和测量设备台帐。负责本项目部检验、试验和测量设备的使用、维修、检定、保养等工作。对项目
18、工程使用的检验、检测、试验、计量、测量设备的状态作出标识,定期复核标识。对计量设备与仪表作使用期的动态检查与监督。项目保管员岗位职责熟悉各类物资的名称、规格、用途、性能和保养知识。严格把好材料、设备进库验收关,建立物资台帐。严格按物资管理工作程序操作,按采购计划及产品标准验收入库,做到手续齐全。认真做好防火、防窃、防潮、防损、防霉变等工作。物资进货检验状态的标识。收集整理质保书、合格证等交项目资料员归档。5、施工流程1、本工程施工流程安排如下:测量放线地基开挖、基槽验收桩机施工基础施工上部框架结构施工填充墙体砌筑内外装饰水暖、电安装穿插进行室外工程验收及交付使用。2基础施工流程放线土方开挖人工
19、清土验槽护坡施工人工挖孔垫层砖胎模砌筑基础绑扎钢筋钢筋隐蔽验收浇注基础混凝土绑扎墙、柱钢筋墙、柱及顶梁板模支设绑扎顶梁、板钢筋隐蔽验收浇注墙、柱及顶梁板混凝土养护进入上部结构施工。3砼结构施工流程放线柱钢筋绑扎柱钢筋隐蔽验收柱模板安装、梁板模板安装梁、板钢筋绑扎梁、板钢筋隐蔽验收柱、梁、板砼浇筑砼养护。4安装工程施工流程各专业工种施工准备预留预埋水、电配管配线管道打压厕所内洁具及其他部位灯具、电控制面板安装管道系统试压冲洗系统调整测试竣工验收。5内装修结构处理放线安装门窗框内墙抹灰水电、设备管线安装安装外墙门窗扇内墙乳胶漆、吊顶地面面层门窗五金油漆涂料灯具、开关清理交工。6外装修屋面工程结构处
20、理外墙打底、保温外墙花岗岩、弹性涂料 清理验收五、施工准备1、技术准备组织有关技术人员对图纸进行学习,了解设计意图,结合现行的施工规范,研究商讨正确的施工方案,编制各分部分项工程的施工方法,绘制施工现场平面布置图。编制施工预算,进行工料分析,编制施工进度控制计划和材料订货计划以及大型机械设备的进场计划。组织有关人员对模板和脚手架的设计和制作,并进行必要的结构验算。对工程进行定位并将绝对高程引测到施工现场,设置坐标和标高控制点,埋设永久性控制点。与气象部门取得联系,掌握历年的气象资料编制各阶段的施工技术措施。与工程质量检测部门取得联系,提前进行配合比试验以及各种进场的二次化验。制定工程技术、质量
21、、安全、消防、保卫、计划经营、财务、设备材料和机具等系列管理制度,完善管理体系。2、施工机械、设备组织及计划根据本工程特点,经我公司充分考虑,同时对现有设备进行调整后,按下列思路配制设备如下:1、场内垂直运输机械:本工程为全现浇钢筋混凝土框架结构,地面积为650平方米,屋脊高度为12.5米,位置处于山坡上,施工场地紧等特点,我公司拟在本工程上投入一台井架作为主体结构的垂直运输和各楼层上的水平运输的机械,一台ZL30F装载机和一台HBT60C混凝土输送泵和一台配料机。2、挖土设备:土方用反铲挖掘机开挖,现场配备斗容量1m3的反铲挖掘机2台,进行基础土方的开挖。3、搅拌设备:砌筑及装修等工程采用二
22、台JZ350搅拌机。主体结构施工用混凝土均采用商品砼。(4)钢筋机械:现场设钢筋加工棚,在钢筋棚内各设钢筋弯曲机、切断机和卷扬机各1台。本工程的钢筋焊接主要采用电弧焊、闪光对焊等,现场设2台交流电焊机、一台钢筋对焊机。(5)木工机械本工程的钢筋砼楼板主要采用木模板,现场设一个木工棚,配圆锯2台,可满足施工要求。另设1台刨床、1台钻床。(6)其它机械:其它机械根据施工机具需要量情况及现场施工进度要求分批组织进场,并做好保养和试运等项工作,一些常用的机械及设备配件要有一定数量的储备以便及时替换,保证各种机械正常运转。另外现场配备0.5吨的客货车一辆(自备),负责现场值班和材料的采购,其它机具设备见
23、附件主要施工机械设备表3、施工周转物资准备施工前的物资准备主要是周转材料的加工准备和大宗材料的订货准备,应以总进度计划为依据,逐步安排物资进场,既保证施工顺利进行,又不积压材料,过分占用资金。周转材料的投入、安排序号名 称规 格数 量备 注1普通钢管4880T分批进场2扣 件10000只扣件按三种类型备齐3高强覆膜竹胶合板15mm厚122024402000 m2分批进场4高强覆膜竹胶合板12mm厚122024403000m2模板分批进场6木 方50100、2505090m3分批进场7安 全 网底网1.0m6m80张侧网1.8m6m300张4、人员准备1、组织成立项目经理部,配备各级各部门的管理
24、人员,完善现场管理体制,落实具体人员。2、根据工程特点和施工计划,编制人员进场计划,并根据现场的施工进度调配劳动力,组织各工种人员分批进场。5、材料供货组织本工程主要施工原材料包括:水泥,钢筋,砂子,石子,砌块,木材,复合木模板等,这些材料由地方建筑材料加工厂、建筑市场采购。水泥、钢材等重要材料,按照建设单位的意见,必须采用省级及省级以上的知名品牌产品。大宗材料由项目工程部、物资部在开工前向项目经理部提供总体需用计划,由分公司选择经ISO9002体系认可的合格物资供应商,进行货比三家后,与供货商签订采购定货合同,并通过业主及有关部门审批。6、现场准备1、进入现场后,应及时与建设单位取得联系,在
25、现场达到“三通一平”的基础上将施工用电、用水引到各个使用点,布置现场的施工道路,施工前必须做到路通、水通、电通、场地平整。2、按照施工现场平面布置图在施工现场布置仓库、水泥库、钢筋棚、木工棚、配电室等;(办公室、会议室、食堂、宿舍、厕所、浴室等甲方提供)。3、施工用水:安装布设现场施工用水管线,现场内施工用水采用DN50焊接钢管,由甲方指定用水点接至施工现场;在0.00门厅处设置一台高压水泵,加压后送至各楼层再用DN25的钢管引至各用水点,以满足施工的需要。现场排水沟应根据现场的地势在建筑物四周布置排水沟,将场地铲成坡度,坡向排水沟,做到集中排水。4、施工用电:施工现场的用电由于工期较紧,考虑
26、到主体结构施工时机械全部使用,其现场用电量估算如下: P计=1.1(+K1Pa+K2Pb)其中:Pa为现场全部施工用电设备额定电量之和,取75KWPb为照明用电设备额定用量之和,取15KWK1、K2分别为机械设备,照明设备全部使用的系数,根据本工程的特点和主要施工机械设备表,K1取0.7,K2取1,经计算:则P计=1.1*(90*0.7+15*1)=67.5KW由此可求得现场所需变压器容量P变=1.05P计/cos,cos为用电设备因素,一般施工现场取0.75,则P变=94.5KVA,因此本工程现场需配备100KVA容量以上的变压器。5、树木保护:一层门厅处原有的几棵树木,进场后利用竹篙延树木
27、四周搭设立杆间距不大于1m、步距不大于1.8m的防护架,底曾做一道彩刚板的封闭防护。西侧树木距基坑很近,在土方开挖时尽量保留树木,然后采取竹篙架方式进行防护。六、主要分部分项工程施工方法及技术措施1、工程测量与施工放线1.轴线测量根据规划测绘部门出据的轴线定位点,用J2经纬仪将主轴线引测到建筑物以外。并设置永久性控制点,形成十字轴线控制网,然后按图纸尺寸和轴线关系用J2经纬仪和50米的钢尺引测其余轴线以供基础部分使用。0.000以上施工测量,轴线引测采用内控激光铅锤法,在基础部分施工完毕后,根据轴线控制网将主轴线引测地下室顶板上,并设3个永久性控制点,现浇上两层楼板时将此3个控制点的垂直上方位
28、置预留150*150的方洞,形成上下垂直通视以便引测轴线控制线。每层的轴线定位,均以一层处的3个控制点为基准点,采用垂准仪引测到各楼层上,然后根据轴线,用经纬仪和50m钢尺进行各楼层的轴线定位。框架柱的定位放线按各楼层的轴线控制线和图纸尺寸弹出柱的边框线,外侧300mm处弹出控制线,以便校正模板和检查验收。框架梁的定位:将轴线从柱根部引测到其顶部,然后根据梁与轴线的关系进行定位。2.高程测量高程测量:采用S3水准仪和5m标尺以规划测绘部门出具的绝对高程控制点为基准点,将其标高引测到施工现场并设置永久性基准点,且计算出永久性基准点的标高,然后根据这些基准点的标高确定0.000的位置并设置在龙门桩
29、上,基础施工时,采用S3水准仪和5m标尺,从龙门桩或永久控制点将标高引测到基坑内。0.000以上各楼层标高引测,采用S3水准仪和50m钢尺以0.000为基准点从电梯井内将标高引测到各楼层的柱上,各楼层再用S3水准仪在柱子上抄出500mm高的水平线,以便梁板支模和控制楼层标高。3.测量放线的基本要求1)施工放线(1)、落实专人负责制,设一名工程师专职施工放线,配备施测工2人。(2)执行现场定位、放线均经自检、专职质检员验收后,并请监理工程师或业主代表复查验收的原则。(3)轴线和标高的验收与支模的验收并重,特别是保证轴线和标高准确的重要环节。2)验线(1)专职质检员验线要从审核测量放线方案开始,在
30、各主要阶段施工前,工程项目技术负责人均要对测量放线工作提出预防性要求,真正做到防患于未然。(2)验线的依据要原始、正确、有效。(3)验线的主要部位引测桩点,与周围定位条件。主轴线与其控制桩。原始水准点、引测标高点和0.000标高线。3)测量记录和计算工作(1)、测量做到原始、真实、正确、清晰,并现场及时复核记录。(2)、计算做到:依据正确、方法科学、严谨有序、步步校核、结果无误。4)仪器、工具用具的使用和保养(1)测量仪器使用和保养专人使用、专人保管、专人防护。使用前有合格准用标识,并采用水三角网试测闭合检查无误,方可使用。仪器安置后不得离开,并注意防止外来物体打击和碰撞。水准仪、经纬仪平时加
31、强保养,正常情况下按检定周期(一年)进行校验一次,若出现故障及时送法定专业检修部门修理、检定。(2)、钢尺、水准尺、标杆使用正确使用钢尺、严禁踩压,用后及时清理擦油。水准尺、标杆在施测时,应认真扶正,严禁侧立和靠立。采用线坠吊线时,大风天禁止使用。4.施工测量前的准备工作熟悉图纸,全面了解建筑物的平、立、剖面的形状和尺寸、构造,并复核图纸各部位尺寸,它是整过施工放线过程的依据。认真学习,领会施工组织设计,全盘掌握施工段的划分,施工先后次序、进度安排和施工现场的临时设施位置。5.精度要求施工放线必须先进行测角,量边或方向控制点检核,符合要求后方可大面放样。基础轴线允许偏差:L30m 5mm30m
32、L60m 10mm60m90m 20mm本工程允许误差:L30m 5mm30mL90m 8mm各层柱身的竖向允许偏差不大于5mm,总高度累计竖向允许差250用18厚竹胶板作底模,梁底250mm采用50mm厚硬松板平台板模用50100木垫楞楞距为350.b.安装安装顺序为:梁底模梁侧模板底模。支撑搭设:采用钢管48厚3.5作支撑系统。立管间距视层高、梁宽高及板厚定,压杆计算高度取.5.8m。梁下竖支撑间6001000,保证支撑体系具有较好的稳定性。安装要求:当梁截面高度等于500800mm时,在截面二分之一处,每隔600设一根12接紧螺栓.当梁高9001500mm设两根对拉螺杆。梁高1500mm
33、时,采用墙板式支撑,但梁底支撑间距应500。跨度大于4m的梁板均考虑起拱, 起拱高度为净跨长度1/450。梁侧模、梁底模、板底模,柱、梁、板相接处采用18mm厚双面覆膜竹胶板作模板。 楼梯模板楼梯模板均采用木模及扣件式钢管脚手架,墙体砼先浇。楼梯板筋先埋入墙内,墙模拆除后剔出扳直与梯板筋焊接,楼梯砼与上层梁板一同浇筑。楼梯底模板采用18厚双面覆膜竹胶板,底模超出侧模23cm。侧模、踢步模板和踏步模板按图加工成型,现场组装。为保证踏步板一次成型,踢步模板下口背枋倒45度角,便于铁抹子收光。 特殊部位施工a.墙、柱根部处理为确保墙、柱根部不烂根,在安装模板前,所有墙柱模板根部均抹好砂浆找平层,但找
34、平层不能深入墙柱内,抹砂浆找平层用尺子控制找平层的厚度、平整度,作到均匀一致,然后加垫10mm厚海绵条以防止砼浇筑时因漏浆而导致烂根。b.墙板接头处处理要求模板接缝平整且缝隙小。所有模板体系在预制拼装时,将模板刨边,使边线平直,四角归方,接缝平整;梁底边、二次模板接头处和转角处均加垫10mm厚海绵条以防止漏浆。模板安装质量的要求a.现浇结构模板安装和安装在结构上的预埋件和预留孔洞等按图纸和图纸会审不得遗漏,且安装必须牢固,埋件位置必须准确。b.现浇钢筋砼梁、板,当跨度等于或大于4m时,模板须按现行规范要求起拱高度起拱。c.阴阳角必须方正(用工程检测仪上角尺检验)。模板的拆除a.现浇结构的模板及
35、其支架拆除时,均应与监理单位共同采用回弹仪测定砼强度后,并经计算后方进行拆除。b.侧模,在砼强度能保证其表面及棱角不因拆除模板而变形后,方可拆除。c.楼梯模板:铺设楼梯模板从一侧向另一侧密铺,在两端及接头处用钉钉牢,其它部位少用钉,以便拆模。d.雨蓬模板:支模时,先安过梁模板,支好顶撑,再按设计标高铺钉过梁底板,装钉板钉夹木,斜撑、搭头木固定侧板,在雨蓬一面侧板外侧钉托木,一端支撑牵杠撑,上铺雨蓬搁栅和底板,再钉雨蓬侧板即成,拆模方法与楼梯相同。 e.底模,在砼强度符合有关规定后,方拆除。砌筑工程地下部分:a.外墙:均为钢筋砼结构墙体. b.内墙:除钢筋砼结构墙外,砌筑隔墙为100,200厚水
36、泥砌块。地上部分:a.外墙:砌筑墙体采用190厚(图注200)页岩模数砖, b.内墙:砌筑墙体采用90、190厚(图注100、200)加气混凝土。加气混凝土砌块a.材料要求蒸压加气混凝土砌块,一般规格为600200、600250、600300(mm)厚度模数制为25和60(mm)两种进位的加气混凝土砌块。 其强度:当干密度为500kgm3 时,等级为MU3,当干密度为700kg m3时,等级为MU5。设计规定的其它干密度和强度等级的蒸压加气混凝土块,质量应符合部颁标准及蒸压加气混凝土砌块(JC31582)的各项指标要求。水泥:325及其以上的普通硅酸盐或矿渣硅酸盐水泥。砂子:中砂,含泥量不超过
37、5,过5mm孔径筛。b. 主要机具搅拌机,后台计量设备,5mm筛子、手推车、大铲、铁锹、刀锯、镂漕工具带齿刃、手摇钻、线锤、托线板、小白线、灰桶、铺灰铲、小锤、小水桶、水平尺、砂浆吊斗及垂直运输工具等。c.作业条件现场存放场地应夯实,平整,不积水,码放应整齐。装运过程轻拿轻放,避免损坏。并尽量减少二次倒运。根据墙体尺寸和砌块规格,妥善安排砌筑平面排块设计,尽可能地减少现场切割量。根据砌块厚度与结构净空高度及门窗洞口尺寸切实安排好立面、剖面的排块设计,避免浪费。砌加气混凝土块的部位在结构墙体上按500mm标高线分层划出砌块的层数,安排好灰缝的厚度。在相应的部位弹好墙身门洞口尺寸线,在结构墙柱上弹
38、好加气混凝土墙的立面边线。标柱窗口位置。砌筑前应做完地面垫层,加气墙根部先砌好两层实心砖(踢脚高度),或做成混凝土带。门洞两侧可浇注成钢筋混凝土小立柱,作为边框,也可以在砌筑同时按规定间距摆放混凝土预制块(内埋木砖),用来固定门框。砌墙的前一天,应将加气混凝土墙与结构相接的部位洒水湿润,保证砌体粘结牢固。遇有穿墙管线,应预先核实其位置、尺寸。以预留为主,减少事后剔凿,损害墙体。按照设计要求预先在结构墙柱上每1m左右焊好预留拉结钢筋。d. 操作工艺工艺流程:基层处理 砌加气混凝土块 砌块与门窗口联接 砌块与楼板联接基层处理:将砌筑加气混凝土墙根部的砖或混凝土带上表面清扫干净,用砂浆找平,拉线,用
39、水平尺检查其平整度。砌加气混凝土块:砌筑时按墙宽尺寸和砌块的规格尺寸,按排块设计,进行排列摆块,不够整块时可以锯割成需要的尺寸,但不得小于砌块长度的13(60013mm)。竖缝宽20mm,水平灰缝15mm为宜。当最下一皮的水平灰缝厚度大于20mm时,应用豆石混凝土找平层铺砌。砌筑时,满铺满挤,上下丁字错缝,搭接长度不宜小于砌块长度的13,转角处相互咬砌搭接。双层隔墙,每隔两皮砌块钉扒钉加强,扒钉位置应梅花形错开。砂浆标号按设计规定。加气墙与结构墙柱联接处,必须按设计要求设置拉结筋。设计无要求时,竖向间距为500mm左右,埋压26钢筋。埋直平铺在水平灰缝内,两端伸入墙内不小于70mm。未预留拉结
40、筋部位,需要用粘结砂浆粘结,粘结砂浆的重量配合比为:水泥:901胶:中砂(用窗纱过筛)1:0.2:2。砌块端头与墙柱接缝处各涂刮厚度为5mm的粘结砂浆,挤紧塞实,将挤出的砂浆刮平。墙体应有可靠的拉结。一般每1.5m的高度预留26钢筋伸入墙内,平铺在灰缝内作为拉结。当墙的高度大于3m时,应按设计规定做钢筋混凝土拉带。如设计无规定时,一般每隔1.5m加设26或56钢筋带,确保墙体的整体稳定性。砌块与门窗口联结:如采用后塞口时,将预制好埋有木砖或铁件的混凝土块,按洞口高度在2m以内每侧砌置三块,洞口高度大于2m时砌置四块,混凝土块四周的砂浆要饱满密实(如门框的用料为黄花松,每侧应砌置四块混凝土块)。
41、安装门框时用手钻在边框上预先钻好钉眼,然后用钉子将门框与混凝土内的木砖钉牢。也可以将门窗洞口周边做成钢筋混凝土边框,边框与门窗木框边缝的余量每边为15mm,混凝土边框内再留木砖或铁埋件。门窗上口及窗洞口一般可做成钢筋混凝土拉结带,且全长贯通,以增强加气混凝土墙体在门窗洞口等薄弱部位的整体性。如采用先立口时,砌块和门框外侧,均涂抹粘结砂浆5mm,挤压密实,同时校正墙面的垂直、平整和门框的位置。随即每侧在木框上均匀地钉三个将钉帽砸扁的钉子与加气混凝土块钉牢。方法是钉子预先钉在门框上,且钉帽外露,待砌筑高度超过钉子时,再往砌块里钉。门洞上角过梁端部或其它可能出现裂缝的薄弱部位,应钉涂有防锈漆的铅丝网
42、,减少抹灰层裂缝。门窗口过梁部位,当洞口宽度小于500mm时,又无钢筋混凝土带,可采用三个砌块先加工成楔形,用粘结砂浆事先粘结成过梁形状,经自然养护23d之后使用。砌筑时先在门窗口上槛及压脊部位铺粘结砂浆后安装就位。当洞口宽度大于500mm时,上口可按上述做成钢筋混凝土拉带梁。砌块与楼板(或梁底)的联结:楼板的底部(或梁底),应预留拉结筋 ,便于与加气混凝土墙体拉结。当楼板或梁底未事先留置拉结筋时,先在砌块与楼板接触处涂抹粘结砂浆,用力挤严实,每砌完一块用小木楔(间距约600mm)在砌块上皮紧贴楼板底(或梁底)背紧,用粘结砂浆填实,灰缝刮平。或在楼板底(梁底)斜砌一排砖,以保证加气混凝土墙体顶
43、部稳定、牢固。e.质量标准保证项目:使用的原材料和加气混凝土块品种,强度必须符合设计要求,质量应符合现行蒸压加气混凝土砌块标准的各项技术性能指标,并有出厂合格证。砂浆的品种标号必须符合设计要求。砌块接缝砂浆必须饱满,按规定制作砂浆试块,试块的平均抗压强度不得低于设计强度,其中任意一组的最小抗压强度不得小于设计强度的75。转角处必须同时砌筑,严禁留直槎,交接处应留斜槎。基本项目通缝:每道墙3皮砌块的通缝不得超过3处,不得出现四皮砌块及四皮砌块高度以上的通缝。灰缝均匀一致。接槎:砂浆要密实,砌块要平顺,不得出现破槎、松动,做到接槎部位严实。拉结筋(或钢筋混凝土拉结带):间距、位置、长度及配筋的规格
44、、根数符合设计要求。位置、间距的偏差不得超过一皮砌块,在灰缝中设置,视砌块的厚度而调整。f.成品保护门框安装后施工时应将门框两侧300600高度范围钉铁皮保护,防止施工中撞坏。砌块在装运过程中,轻装轻放,计算好各房间的用量,分别码放整齐。搭拆脚手架时不要碰坏已砌墙体和门窗口角。落地砂浆及时清除,收集再用。以免与地面粘结,影响下道工序施工。设备槽孔以预留为主,尽量减少剔凿,必要时剔凿设备孔槽不得乱剔硬凿损坏,可划准尺寸用刀刃镂划。如造成墙体砌块松动,必须进行补强处理。g. 应注意的质量问题碎块上墙。原因是施工搬运中损坏较多,事前又不进行粘结,随意将破碎块砌墙,影响墙体的强度。应在砌筑前先将断裂块
45、加工粘制成规格尺寸,然后再用。碎小块未经加工不得使用。墙体与板梁底部的连接不符合要求,出现较大空隙。原因是结构施工时板、梁底部未事先留置拉结筋,砌筑时又不采取拉结措施,影响墙体的稳定性。在结构施工时按要求在板、梁底部留好拉结筋,按要求做到墙顶连接牢固。粘结不牢。原因是用混合砂浆加901胶代替粘结砂浆使用,导致粘结不牢。应按操作工艺要求的配合比调制粘结砂浆,砌筑时用力挤压密实。拉结钢筋不符合规定。原因是拉结筋、拉结带不按规定预留、设置,造成砌体不稳定。拉结筋、拉结带应按设计要求留置,具体间距可视砌块灰缝而定,但不大于100mm。门窗洞口构造做法不符合规定。原因是未事先加工混凝土块,不符合设计构造
46、大样图的规定,造成门窗洞口不牢。应先预制加工好足够的混凝土垫块,注意过梁梁端压接部位按规定放好四皮机砖,或放混凝土垫块。宜在门窗洞上口设钢筋混凝土带并整道墙贯通。灰缝不匀。原因是砌筑前对灰缝大小不进行计算,不作分层标记,不拉通线,使灰缝大小不一致,应先对墙体尺寸及砌块规格进行安排,适当调配皮数,将灰缝作出标记,拉通线砌筑,做到灰缝基本一致,墙面平整,灰缝饱满。排块及局部做法不合理。原因是砌筑前对整体立面、剖面及水平砌筑时不按规定排块,造成构造不合理,影响砌体质量。砌筑时排块及构造做法,应依照建筑构造通用图集88J2(二)的有关规定执行。水泥砌块a.材料要求水泥:325及其以上的普通硅酸盐或矿渣
47、硅酸盐水泥。砂子:中砂,含泥量不超过5,过5mm孔径筛。b.主要机具搅拌机,后台计量设备,5mm筛子、手推车、大铲、铁锹、刀锯、镂漕工具带齿刃、手摇钻、线锤、托线板、小白线、灰桶、铺灰铲、小锤、小水桶、水平尺、砂浆吊斗及垂直运输工具等。c.作业条件现场存放场地应夯实,平整,不积水,码放应整齐。装运过程轻拿轻放,避免损坏。并尽量减少二次倒运。根据墙体尺寸和砌块规格,妥善安排砌筑平面排块设计,尽可能地减少现场切割量。根据砌块厚度与结构净空高度及门窗洞口尺寸切实安排好立面、剖面的排块设计,避免浪费。在基础柱上按标高分层划出砌块的层数,安排好灰缝的厚度。砌墙的前一天,应将砖与结构相接的部位洒水湿润,保
48、证砌体粘结牢固。遇有穿墙管线,应预先核实其位置、尺寸。以预留为主,减少事后剔凿,损害墙体。按照设计要求预先在结构墙柱上每1m左右焊好预留拉结钢筋。d.操作工艺工艺流程:基层处理:将墙根部位置或混凝土带上表面清扫干净,用砂浆找平,拉线,用水平尺检查其平整度。砌砖:砌筑时按墙宽尺寸和砌块的规格尺寸,按排块设计,进行排列摆块,不够整块时可以锯割成需要的尺寸,但不得小于砌块长度的13(60013mm)。竖缝宽20mm,水平灰缝15mm为宜。当最下一皮的水平灰缝厚度大于20mm时,应用豆石混凝土找平层铺砌。砌筑时,满铺满挤,上下丁字错缝,搭接长度不宜小于砌块长度的13,转角处相互咬砌搭接。双层隔墙,每隔
49、两皮砌块钉扒钉加强,扒钉位置应梅花形错开。砂浆标号按设计规定。砌块与结构柱联接处,必须按设计要求设置拉结筋。设计无要求时,竖向间距为500mm左右,埋压26钢筋。埋直平铺在水平灰缝内,两端伸入墙内不小于70mm。未预留拉结筋部位,需要用粘结砂浆粘结,粘结砂浆的重量配合比为:水泥:901胶:中砂(用窗纱过筛)1:0.2:2。砌块端头与墙柱接缝处各涂刮厚度为5mm的粘结砂浆,挤紧塞实,将挤出的砂浆刮平。墙体应有可靠的拉结。一般每1.5m的高度预留26钢筋伸入墙内,平铺在灰缝内作为拉结。当墙的高度大于3m时,应按设计规定做钢筋混凝土拉带。如设计无规定时,一般每隔1.5m加设26或56钢筋带,确保墙体
50、的整体稳定性。砌块与梁底的连结:梁底应预留拉结筋,便于与粉煤灰砖墙体拉结。当梁底未事先留置拉结筋时,先在砌块与梁底接触处涂抹粘结砂浆,用力挤严实,每砌完一块用小木楔(间距约600mm)在砌块上皮紧贴梁底背紧,用粘结砂浆填实,灰缝刮平。或在梁底斜砌一排砖,以保证粉煤灰砖墙体顶部稳定、牢固。e.质量标准保证项目:使用的原材料和砌块品种,强度必须符合设计要求,质量应符合有关标准的各项技术性能指标,并有出厂合格证。砂浆的品种标号必须符合设计要求。砌块接缝砂浆必须饱满,按规定制作砂浆试块,试块的平均抗压强度不得低于设计强度,其中任意一组的最小抗压强度不得小于设计强度的75。转角处必须同时砌筑,严禁留直槎
51、,交接处应留斜槎。基本项目通缝:每道墙3皮砌块的通缝不得超过3处,不得出现四皮砌块及四皮砌块高度以上的通缝。灰缝均匀一致。接槎:砂浆要密实,砌块要平顺,不得出现破槎、松动,做到接槎部位严实。拉结筋(或钢筋混凝土拉结带):间距、位置、长度及配筋的规格、根数符合设计要求。位置、间距的偏差不得超过一皮砌块,在灰缝中设置,视砌块的厚度而调整。f.成品保护砌块在装运过程中,轻装轻放,计算好用量,分别码放整齐。搭拆脚手架时不要碰坏已砌墙体。设备槽孔以预留为主,尽量减少剔凿,必要时剔凿设备孔槽不得乱剔硬凿损坏,可划准尺寸用刀刃镂划。如造成墙体砌块松动,必须进行补强处理。g.应注意的质量问题碎块上墙。原因是施
52、工搬运中损坏较多,事前又不进行粘结,随意将破碎块砌墙,影响墙体的强度。应在砌筑前先将断裂块加工粘制成规格尺寸,然后再用。碎小块未经加工不得使用。墙体与板梁底部的连接不符合要求,出现较大空隙。原因是结构施工时板、梁底部未事先留置拉结筋,砌筑时又不采取拉结措施,影响墙体的稳定性。在结构施工时按要求在板、梁底部留好拉结筋,按要求做到墙顶连接牢固。粘结不牢。原因是用混合砂浆加901胶代替粘结砂浆使用,导致粘结不牢。应按操作工艺要求的配合比调制粘结砂浆,砌筑时用力挤压密实。拉结钢筋不符合规定。原因是拉结筋、拉结带不按规定预留、设置,造成砌体不稳定。拉结筋、拉结带应按设计要求留置,具体间距可视砌块灰缝而定
53、,但不大于100mm。灰缝不匀。原因是砌筑前对灰缝大小不进行计算,不作分层标记,不拉通线,使灰缝大小不一致,应先对墙体尺寸及砌块规格进行安排,适当调配皮数,将灰缝作出标记,拉通线砌筑,做到灰缝基本一致,墙面平整,灰缝饱满。排块及局部做法不合理。原因是砌筑前对整体立面、剖面及水平砌筑时不按规定排块,造成构造不合理,影响砌体质量。砌筑时排块及构造做法,应依照建筑构造通用图集88J2(二)的有关规定执行。页岩模数砖a.施工准备砖:品种、规格、强度等级必须符合设计要求,规格应一致。有出厂证明、试验报告单。 水泥:一般用325号矿渣硅酸盐水泥或普通硅酸盐水泥,有出厂证明、复试报告。 砂:宜用中砂,过5m
54、m孔径筛子,配制M5以下砂浆,砂含泥量不超过10%,M5及其以上砂浆,砂的含泥量不超过5%,并不含草根等杂物。掺合料:选用石灰膏、粉煤灰、磨细生石灰粉等。生石灰熟化时不得少于7d。 水:用自来水或不含有害物质的洁净水。 其它材料:拉结钢筋、预埋件、木砖等,提前做好防腐处理。 b.主要机具:备有搅拌机、翻斗车、磅秤、吊斗、砖笼、手推车、胶皮管、筛子、铁锹、半截灰桶、喷水壶、托线板、线坠、水平尺、小白线、砖夹子、大铲、瓦刀、刨锛、工具袋等。c.作业条件:主体分部中承重结构已施工完毕,已经有关部门验收。 弹出轴线、墙边线、门窗洞口线,经复核,办理预检手续。 立皮数杆:宜用30mm40mm木料制作,皮
55、数杆上注明门窗洞口、木砖、拉结筋、圈梁、过梁的尺寸标高。皮数杆间距1520mm,转角处均应设立,一般距墙皮或墙角50mm为宜。皮数杆应垂直、牢固、标高一致,经复核,办理预检手续。 根据最下面第一皮砖的标高,拉通线检查,如水平灰缝厚度超过20mm,用细石混凝土找平,不得用砂浆找平或砍砖包合子找干。 常温天气在砌筑前一天将砖浇水湿润,冬期施工应清除表面冰霜。 砂浆配合比经试验室确定,准备好砂浆试模。d. 操作工艺 工艺流程: 拌制砂浆 施工准备排砖撂底砌空心砖墙验评砌筑前,基础墙或楼面清扫干净,洒水湿润。根据设计图纸各部位尺寸,排砖撂底,使组砌方法合理,便于操作。e.拌制砂浆: 砂浆配合比应用重量
56、比,计量精度为,水泥2%,砂及掺合料5%。 宜用机械搅拌,投料顺序为砂水泥掺合料水,搅拌时间不少于l.5min。 砂浆应随拌随用,水泥或水泥混合砂浆一般在拌合后34h内用完,严禁用过夜砂浆。 每一楼层或250m3砌体的各种强度等级的砂浆,每台搅拌机至少应作一组试块(每组6块),砂浆材料、配合比变动时,还应制作试块。f.砖墙体: 组砌方法应正确,上下错缝,交接处咬槎搭砌,掉角严重的空心砖不宜使用。 水平灰缝不宜大于15mm,应砂浆饱满,平直道顺,立缝用砂浆填实。 空心砖墙在地面或楼面上先砌三皮实心砖,空心砖墙砌至梁或楼板下,用实心砖斜砌挤紧,并用砂浆填实。 空心砖墙按设计要求设置构造柱、圈梁、过
57、梁或现浇混凝土带。 各种预留洞、预埋件等,应按设计要求设置,避免后剔凿。空心砖墙门窗框两侧用实心砖砌筑,每边不少于24cm 。 转角及交接处同时砌筑,不得留直槎,斜槎高不大于1.2m。 拉通线砌筑时,随砌、随吊、随靠,保证墙体垂直、平整,不允许砸砖修墙。g.冬雨期施工: 期砂浆宜用普通硅酸盐水泥拌制,砂子不得含冻块。 空心砖表面粉尘、霜雪应清除干净,砖不宜浇水,适当增大砂浆稠度。 采用掺盐砂浆,其掺盐量、材料加热温度应按冬施工方案规定执行,砂浆使用温度不应低于+5。拉结筋、预埋件要做好防腐处理。h. 质量标准空心砖的品种、规格、强度必须符合设计要求,有出厂合格证、试验报告。砂浆品种必须符合设计
58、要求,强度必须符合下列规定:同品种、同强度等级砂浆各组试块平均强度不小于fm,k。任意一组试块强度不小于0.75fm,k。空心砖砌体水平灰缝砂浆饱满,立缝填塞密实。 转角处严禁留直槎,其它部位应留斜槎。小型构件安装工程 小型构件安装要搭设便于操作的平台。小型构件安装前,先在墙体上弹好水平线,以此为依据,用1:25的水泥砂浆找平,厚度不超过20mm。安装时用1:3水泥砂浆座浆,厚度不超过20mm要求座平座实,不允许用砌筑混合砂浆座浆。4、 屋面工程1、屋面工程施工时应严格按图纸和施工规范及标准图集进行施工。隔汽层、柔性防水层的在泛水处及凸出屋面的部分应高出屋面 250mm。2、保温层施工前应检查
59、屋面上管道及电气的预埋是否施工完毕,并进行验收,合格后方可施工保温层,找坡层的坡度应准确。3、刚性防水层施工时应严格控制水灰比和砂石的含泥量,以及砼的坍落度,砼表面应括平压光。刚性防水层表面分格缝,通缝纵横向每6M设置一道,半缝纵横向每1M设置一道,均采用A型密封胶填满。柔性防水层施工后必须进行24小时蓄水试验。4、屋面施工时应对每道工序严格把关,必须经验收合格后方可进行下道工序的施工。具体施工时将根据施工图要求另行编制详细施工方案和技术措施。5、建筑装饰装修工程主体结构完成以后立即进行室内装修,其原则为由上而下,先室外、后室内依次进行,切不可颠倒工序,根据本工程的特点和工期要求,室内外装修可
60、同时穿插进行,并与主体砌筑利用时间差和空间位置形成立体交叉作业。1、抹灰工程工艺流程:门窗框四周堵缝1:1.2水泥砂浆养护不少于10天墙面清理浇水润湿墙面吊垂直套方、抹灰饼、冲筋弹灰层控制线基层处理抹底层砂浆抹罩面灰养护。施工准备抹灰前,必须对上道工序进行检查,并作隐蔽验收及主体结构验收。同时检查门窗框安装、穿过墙壁的各种管道套管、设在墙壁内配电箱、插座盒等是否安装完毕。各种原材料技术要求水泥:有化验报告单及合格证,不得受潮变质,安定性必须合格,品种为普通32.5硅酸盐水泥。砂子:干净无杂质,含泥量不大于3%的中砂,使用前过筛,以确保砂的含泥量达标。防水粉:必须持质保书及合格证,且不变质。抹灰
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 广告安装承包合同
- 旅游产品规划与开发作业指导书
- 企业年度工作总结与报告手册
- 亿峰地坪施工方案
- 野外钢架平台施工方案
- 多层水泥路面铺贴施工方案
- 园林圆石铺路施工方案
- 铝合金围墙施工方案
- 小学一年级家长会发言稿
- 幼儿园环境升级施工方案
- 2022年安徽医科大学第一附属医院临床医技、护理、管理岗位招聘187人笔试备考题库及答案解析
- 弟子规42+用人物须明求+教案
- 微电网-储能电池catl pet80ah电芯规格书
- GB/T 4209-2022工业硅酸钠
- 2023年江苏农林职业技术学院高职单招(数学)试题库含答案解析
- GB/T 39242-2020无损检测超声检测灵敏度和范围设定
- GB/T 32271-2015电梯能量回馈装置
- GB/T 18775-2009电梯、自动扶梯和自动人行道维修规范
- GB/T 1.2-2020标准化工作导则第2部分:以ISO/IEC标准化文件为基础的标准化文件起草规则
- 《社会历史的决定性基础》课件2 【知识建构+备课精研】统编版高中语文选择性必修中册
- 消毒供应中心火灾应急预案演练记录
评论
0/150
提交评论