版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1、Tatiana KuznetsovaUniversity of Leuven, Belgium The InGenious HyperCare European Network Excellence in phenotyping: Assessment of left ventricular functionOutlineSystolic functionDiastolic function Echocardiographic protocol (JRP A3)LVFSystolic functionConventional echocardiography enables the asses
2、sment of LV dimensions, volumes, sphericity index, and severity of mitral regurgitation; HF due to systolic dysfunction is relatively easy to diagnose by echocardiography. (dilated left ventricle with a reduced ejection fraction)LVF Radial function Longitudinal CircumferentialComponents of regional
3、functionLVFWithout the longitudinal component, sarcomere shortening would lead to an EF 30%. Tissue Doppler imagingTissue Doppler Imaging (TDI) makes it possible to specifically evaluate the longitudinal and radial components of regional LV systolic function.Measurements of myocardial deformation wi
4、th the Doppler technique have been validated using microcrystals and MRI (Urheim S, Circulation 2000; Edvardsen T, Circulation 2002). LVFBasal segments of inferior and infero-lateral wallsAVCMVOTimeintegrationPeak systolic SREnd-systolic SStrainStrain rateAVCMVOLVFOff-line analysisSPEQLE: Software P
5、ackage for Echocardiographic Quantification, Leuven; version 4.06Inter-observer differences in percent versus average of two readingsLVFBland and Altman, 1986 Mean of 2 readingsLongitudinal S and SR by RWT LVFMean values are adjusted; * P 0.05 *P0.001 Regional LV geometry LVFWall stress related to:P
6、ressure Shape, cavity size Wall thickness = P x R / 2WTSince R curvature is larger in longitudinal direction, the stress on longitudinal fibres is higher, they show decreased deformation first. Systolic functionTDI, compared with conventional echocardiography, is a more sensitive method for the dete
7、ction of LV systolic dysfunction, particularly in subjects with LV remodelling and normal EF.Our observations underscore the importance of normal long axis function in maintaining a coordinated ventricular contraction. The clinical utility of strain and strain rate in risk stratification or as thera
8、peutic target remains to be established.LVFDiastolic functionAbout 50% of patients with new onset of HF do have a normal EF (HF with preserved EF). HF with preserved EF is associated with a high mortality rate, comparable to that of patients with reduced EF. (Bhatia R.S., N Engl J Med 2006; Bursi F.
9、, JAMA 2006)Assessment of diastolic function requires conventional and Tissue Doppler Imaging LVFTransmitral blood flow vs pulsed Tissue Doppler Imaging EAEaAaLVFLVFMean of 2 readingsInter-observer differences in percent versus average of two readingsBland and Altman, 1986 Determinants of TDI veloci
10、tiesStepwise analysis: Ea: age, BMI, DBP, LVMI; LV length, EF; Aa: age, HR, DBP, LV length, EF;Ea/Aa: age, BMI, HR, DBP. Intrafamilial correlation coefficients (P0.0001 for all) were: Ea: 0.43; Aa: 0.41; Ea/Aa: 0.46.LVFEchocardiographic performance protocolEchoA single observer performs all echocard
11、iographic examinations by means of Vivid 7 ultrasound scanner (GE Vingmed, Horten, Norway)Standardized echocardiography scanning sequence (about 40 min, 77 MOP JRP A3)Correct orientation of the ultrasound beam and imaging planes to LV structure and blood flow is essentialAll echocardiographic examin
12、ations in a digital format are stored on a local network for off-line reading by two independent observers (EchoPack, GE and SPEQLE, University of Leuven) Methods to limit echocardiographic measurement variabilityUse echocardiography central reading laboratory: a. Minimize number of readers,b. Monit
13、or reader variability,c. Rapid communication with study sites on study quality.Standardized “hands-on training of sonographers onsite.Monitoring of sonographers for technical quality; encode study quality in database.American Society of Echocardiography Recommendations for Use of Echocardiography in
14、 Clinical Trials. J Am Soc Echocardiogr 2004;17:1086-1119EchoMethods to limit echocardiographic measurement variabilityReading off-line strategies: Batch read when possible to minimize systematic temporal drifts;Average multiple beats (minimum of 3);Single reader preferable. Establish acquisition an
15、d reader variability:Test-retest of small sample of participants, ie, same participant repeated over small interval, same machine, same sonographer, same reader; Blind duplicates for inter-reader and intra-reader variability assessment.EchoKatholieke Universiteit Leuven, B JA Staessen, T Kuznetsova, T RichartJagiellonian University Cracow, PL K Kawecka-Jaszcz, K Stolarz, M LosterMedical University of Gdansk
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025年中国推送式烧结炉市场调查研究报告
- 2025年中国手开二节伞市场调查研究报告
- 2025年中国快速气候牢度测试仪市场调查研究报告
- 2025年中国弹性阀座闸阀市场调查研究报告
- 2025年中国带法兰头自攻螺钉市场调查研究报告
- 嘉兴市2025浙江嘉兴市南湖区教育体育局所属事业单位招聘1人笔试历年参考题库典型考点附带答案详解
- 2026学年浙江省江山市四年级语文期末高分名校真题(详细参考解析)详细答案和解析
- 呼伦贝尔市2025伦贝尔市委政法委员会所属事业单位人才引进人岗相适评估工作笔试历年参考题库典型考点附带答案详解
- 厦门市2025福建厦门港口管理局所属事业单位编内工作人员笔试历年参考题库典型考点附带答案详解
- 南京市2025江苏省社会科学院招聘工作人员17人笔试历年参考题库典型考点附带答案详解
- 2026年宁波慈溪供销集团公司下属单位公开招聘工作人员8人笔试备考题库及答案详解
- 水利工程建设项目生产安全重大事故隐患直接判定清单(指南)
- 2026年成都中考语文测试题及答案
- 2025年北京第二次高中学业水平合格考地理试卷真题(含答案详解)
- 2026译林英语三年级下册期末试卷含听力材料和答案
- 2026年多重耐药菌医院感染预防与控制培训课件
- 动火施工方案样本(3篇)
- 教学方法培训课件
- 12345市民热线培训
- GB 4053.3-2025固定式金属梯及平台安全要求第3部分:工业防护栏杆及平台
- 人工智能导论 课件 第8章 大模型与具身智能
评论
0/150
提交评论