1、 CONOCOPHILLIPS CHINA Bohai Peng Lai ENERGY ISOLATION PLAN Serial No.EQUIPMENT DESCRIPTION: ENERGY TYPE: Circle one or more of the following and list working pressure of the system.ELECTRICAL - YES/NO VOLTAGE - MECHANICAL - YES/NOPRESSURE - HYDRAULIC - YES/NO PRESSURE -PNUEMATIC - YES/NO PRESSURE -

2、ISOLATION TYPE: Circle all that are applicable.CLC = Chain Locked ClosedTC = Tagged ClosedDBB = Double Block & BleedBLO = Breaker Locked OutPB = Paddle BlindCLO = Chain Locked OpenTO = Tagged OpenDB = Double BlockSLO = Switch Locked OutPRB = Pressure Rated BlindCSO = Car Sealed OpenCSC = Car Sea

3、led ClosedSB = Single BlockASD = Air Supply DisconnectedCSEE = Critical Safety/ Emergency EquipmentPEOPLE TO PERFORM LOCKOUT/TAGOUT: Shall be Competent Persons EXAMPLE: HOW EQUIPMENT WILL BE ISOLATED, VERIFIED, DE-ISOLATED AND RELEASED. IsolatedDe-IsolatedLock I.DInitialDateVerified byInitialDateVer

4、ified by123456789101. Close inlet valve(s)· Supply gas valve (s)· Suction valve.· PSV · Attach lock and tag.· Impact on upstream equipment(e.g. wells, compressors, SWF etc.)2. Close outlet valve (s)· Discharge valve.· PSV· Attach lock and tag.· Impact on

5、downstream equipment(e.g. wells, compressors, SWF etc.)3. Relieve pressure from isolated area. (Lock valve open)· Verify fluid level in separator.· Verify gas volume in separator/system 4. Verify· Visually verify valves are in proper position. · Open independent valve to verify p

6、ressure is absent (e.g. sample point, needle valve on bull plugs etc.)5. Releases from LO/TO· Determine if purge is needed. (Refer to SOP)· Remove LO/TO· Replace CSO to PSVs6. Return to ServiceAppropriate Isolations have been completed and documentation has been referenced where appli

7、cable.Print and Sign Name For The Following Departments:Process Isolations _ Electrical Isolations _Mechanical Isolations _ Safety Isolations _Section 4 Equipment ReleaseI Authorize The Removal From Service And Isolation Of The Equipment Per The Isolation Plan In Section 3. Authorizer _Date_All Cross Referenced Permits Have Been Closed On This Certificate And I Authorize The De-Isolation Of The Equipment Identified In Section 3.Authorize _Date_Section 4 - CompletionT

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论