1、常见型号氧化锌避雷器0.220.38kV低压避雷器类别避雷器型号避雷器额定电压kV(有效值)系统标称电压kV(有效值)持续运行电压kV(有效值)直流U1mA参考电压kV陡波冲击电流残压kV(峰值)雷电冲击电流残压kV(峰值)操作冲击电流残压kV(峰值)2mS方波电流A(峰值)4/10s冲击电流kA(峰值)低压(H)Y1.5WS-0.28/1.30.280.220.240.60-1.30-5010(H)Y1.5WS-0.50/2.60.500.380.421.20-2.60-50103kV配电型/电站型 类别避雷器型号避雷器额定电压kV(有效值)系统标称电压kV(有效值)持续运行电压kV(有效值
2、)直流U1mA参考电压kV陡波冲击电流残压kV(峰值)雷电冲击电流残压kV(峰值)操作冲击电流残压kV(峰值)2mS方波电流A(峰值)4/10s冲击电流kA(峰值)配电(H)Y5WS-3.8/153.833.07.517.315.012.87540(H)Y5WS-5/15534.07.517.315.012.87540电站(H)Y5WZ-3.8/13.53.833.07.215.513.511.520065(H)Y5WZ-5/13.5534.07.215.513.511.5200653kV配电型/电站型(带脱离装置)配电(H)Y5WS-3.8/15L 3.833.07.517.315.012.
3、87540(H)Y5WS-5/15L534.07.517.315.012.87540电站(H)Y5WZ-3.8/13.5L3.833.07.215.513.511.520065(H)Y5WZ-5/13.5L534.07.215.513.511.5200656kV配电型/电站型类别避雷器型号避雷器额定电压kV(有效值)系统标称电压kV(有效值)持续运行电压kV(有效值)直流U1mA参考电压kV陡波冲击电流残压kV(峰值)雷电冲击电流残压kV(峰值)操作冲击电流残压kV(峰值)2mS方波电流A(峰值)4/10s冲击电流kA(峰值)配电(H)Y5WS-7.6/307.666.015.034.630.
4、025.67540(H)Y5WS-10/301068.015.034.630.025.67540电站(H)Y5WZ-7.6/277.666.014.431.027.023.020065(H)Y5WZ-10/271068.014.431.027.023.0200656kV配电型/电站型(带脱离装置)配电(H)Y5WS-7.6/30L7.666.015.034.630.025.67540(H)Y5WS-10/30L1068.015.034.630.025.67540电站(H)Y5WZ-7.6/27L7.666.014.431.027.023.020065(H)Y5WZ-10/27L1068.014
5、.431.027.023.02006510kV配电型/电站型类别避雷器型号避雷器额定电压kV(有效值)系统标称电压kV(有效值)持续运行电压kV(有效值)直流U1mA参考电压kV陡波冲击电流残压kV(峰值)雷电冲击电流残压kV(峰值)操作冲击电流残压kV(峰值)2mS方波电流A(峰值)4/10s冲击电流kA(峰值)配电(H)Y5WS-12/35.8 (1)12109.618.041.235.830.67540(H)Y5WS-15/45.6 (2)151012.023.052.545.639.07540(H)Y5WS-12.7/5012.71010.225.057.550.042.57540(H
6、)Y5WS-16.5/5016.51013.225.057.550.042.57540(H)Y5WS-17/50171013.625.057.550.042.57540电站(H)Y5WZ-12/32.4 (1)12109.617.437.232.427.620065(H)Y5WS-15/40.5 (2)151012.021.846.540.534.520065(H)Y5WZ-12.7/4512.71010.224.051.845.038.320065(H)Y5WZ-16.5/4516.51013.224.051.845.038.320065(H)Y5WZ-17/45171013.624.051
7、.845.038.32006510kV配电型/电站型(带脱离装置)配电(H)Y5WS-12/35.8L(1)12109.618.041.235.830.67540(H)Y5WS-15/45.6L(2)151012.023.052.545.639.07540(H)Y5WS-12.7/50L12.71010.225.057.550.042.57540(H)Y5WS-16.5/50L16.51013.225.057.550.042.57540(H)Y5WS-17/50L171013.625.057.550.042.57540电站(H)Y5WZ-12/32.4L(1)12109.617.437.232
8、.427.620065(H)Y5WS-15/40.5L(2)151012.021.846.540.534.520065(H)Y5WZ-12.7/45L12.71010.224.051.845.038.320065(H)Y5WZ-16.5/45L16.51013.224.051.845.038.320065(H)Y5WZ-17/45L171013.624.051.845.038.320065注:(1)此型避雷器用于中性点经低电阻接地的电网;(2)此型避雷器用于中性点经消弧线圈接地的电网。310kV并联补偿电容器型类别避雷器型号避雷器额定电压kV(有效值)系统标称电压kV(有效值)持续运行电压kV
9、(有效值)直流U1mA参考电压kV陡波冲击电流残压kV(峰值)雷电冲击电流残压kV(峰值)操作冲击电流残压kV(峰值)2mS方波电流A(峰值)4/10s冲击电流kA(峰值)并联补偿电容器型(H)Y5WR-5/13.55 3 4.0 7.2 -13.5 10.5 400 65 (H)Y5WR-10/271068.014.4-27.021.040065(H)Y5WR-12/32.41269.617.4-32.425.240065(H)Y5WR-15/40.5151012.021.8-40.531.540065(H)Y5WR-17/46171013.624.0-46.035.040065 20kV配
10、电型/电站型类别避雷器型号避雷器额定电压kV(有效值)系统标称电压kV(有效值)持续运行电压kV(有效值)直流U1mA参考电压kV陡波冲击电流残压kV(峰值)雷电冲击电流残压kV(峰值)操作冲击电流残压kV(峰值)2mS方波电流A(峰值)4/10s冲击电流kA(峰值)配电(H)Y5WS-26/68262020.834.078.268.057.87540(H)Y5WS-26/72262020.836.082.872.061.27540电站(H)Y5WZ-30/80302024.043.092.080.068.020065(H)Y5WZ-32/84322027.245.096.784.071.52
11、006520kV配电型/电站型(带脱离装置)配电(H)Y5WS-26/68L262020.834.078.268.057.87540(H)Y5WS-26/72L262020.836.082.872.061.27540电站(H)Y5WZ-30/80L302024.043.092.080.068.020065(H)Y5WZ-32/84L322027.245.096.784.071.52006535kV电站型 / 35kV并联补偿电容器型 类别避雷器型号避雷器额定电压kV(有效值)系统标称电压kV(有效值)持续运行电压kV(有效值)直流U1mA参考电压kV陡波冲击电流残压kV(峰值)雷电冲击电流残压
12、kV(峰值)操作冲击电流残压kV(峰值)2mS方波电流A(峰值)4/10s冲击电流kA(峰值)电站(H)Y5WZ-42/134423533.673.015413411440065(H)Y5WZ-51/134513540.873.015413411440065(H)Y5WZ-52.7/13452.73542.273.015413411440065(H)Y5WZ-54/134543543.273.015413411440065并联补偿电容器用(H)Y5WR-42/134423533.673.0H)Y5WR-51/134513540.873.0H)
13、Y5WR-52.7/13452.73542.273.0H)Y5WR-54/134543543.273.0-134</, DIV>105<, /DIV>40065注:以上型号避雷器上端均可采用硅橡胶高压软电缆引出(默认长度0.6M)。发电机型/电动机型类别避雷器型号避雷器额定电压kV(有效值)系统标称电压kV(有效值)持续运行电压kV(有效值)直流U1mA参考电压kV陡波冲击电流残压kV(峰值)雷电冲击电流残压kV(峰值)操作冲击电流残压kV(峰值)2mS方波电流A(峰值)4/10s冲击电流kA(峰值)外形尺寸发电机用(H)Y5WD-4/9.54
14、3.153.25.710.79.57.640065同10kV电容器型(H)Y5WD-8/18.786.36.311.221.018.715.040065(H)Y5WD-13.5/3113.510.510.518.634.731.025.040065(H)Y5WD-17.5/4017.513.813.824.444.840.032.040065同10kV电容器型(H)Y5WD-20/452015.815.828.050.445.036.040065(H)Y5WD-23/512318.218.031.957.251.040.840065(H)Y5WD-25/56.22520.220.035.462
15、.956.245.040065电动机用(H)Y2.5WD-4/9.5433.25.710.79.57.620065同3kV电站型(H)Y2.5WD-8/18.7866.311.221.018.715.020065同6kV电站型(H)Y2.5WD-13.5/3113.51010.518.634.731.025.020065同10kV电站型 电机中性点型类别避雷器型号避雷器额定电压kV(有效值)系统标称电压kV(有效值)持续运行电压kV(有效值)直流U1mA参考电压kV陡波冲击电流残压kV(峰值)雷电冲击电流残压kV(峰值)操作冲击电流残压kV(峰值)2mS方波电流A(峰值)4/10s冲击电流kA
16、(峰值)外形尺寸 电机中性点用(H)Y1.5WD-2.4/62.43.151.93.4-6.05.020065同10kV电容器型(H)Y1.5WD-4.8/124.86.33.86.8-12.010.020065(H)Y1.5WD-8/19810.56.411.4-19.015.920065同10kV电容器型(H)Y1.5WD-10.5/2310.513.88.414.9-23.019.220065(H)Y1.5WD-12/261215.89.617.0-26.021.640065同10kV电容器型(H)Y1.5WD-13.7/29.213.71811.019.5-29.224.340065(
17、H)Y1.5WD-15.2/31.715.22012.221.6-31.726.440065 变压器、电抗器中性点型类别避雷器型号避雷器额定电压kV(有效值)系统标称电压kV(有效值)持续运行电压kV(有效值)直流U1mA参考电压kV陡波冲击电流残压kV(峰值)雷电冲击电流残压kV(峰值)操作冲击电流残压kV(峰值)2mS方波电流A(峰值)4/10s冲击电流kA(峰值)外形尺寸变压器电抗器中性点(H)Y1.5W-55/13255110447935kV电站型(H)Y1.5W-60/144601104885H)Y1.5W-72/1867211058103H)Y1.5W-73/2007311058.4105-20016540065 电气化铁道型类别避雷器型号避雷器额定电压kV(有效值)系统标称电压kV(有效值)持续运行电压kV(有效值)直流
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 学生评教与反馈实施方案计划
- 静脉治疗报告
- 统编版小学语文二年级下册《语文园地三》精美课件
- 第四单元 《平行四边形的认识》教学设计-2024-2025学年四年级数学上册青岛版(五四学制)
- 养老床位建设服务方案(技术方案)
- 老年骨折手术护理
- 放射科护理相关知识课件
- 培训课件知识产权保护
- 2025年湛江道路客货运输从业资格证模拟考试下载
- 2025年上海货运从业资格证模拟试题答案大全
- 课题申报书:湖北教育援疆在文化润疆中的作用发挥研究
- 巨量千川营销师(初级)认证考试复习题及答案
- 《佛跳墙英文介绍》课件
- 《特斯拉报告分析》课件
- 2025年小学五年级数学(北京版)-家庭生活中的碳排放-1教案
- 2024年12月管理体系认证基础考试真题及答案
- 抖音直播手册【新人必看】
- 延安大学《算法设计与分析》2022-2023学年期末试卷
- 电力系统信号分析与处理课程教学大纲 (一)
- 产品质量知识培训课件
- 医疗安全升级:2024年安全输液管理
评论
0/150
提交评论