版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1、刘忠正:安庆市枞阳县横埠中学食堂结构设计安庆市枞阳县横埠中学食堂结构设计摘 要本课题是一中学食堂的框架结构的设计,结构设计主要是取一榀框架,为三层、三跨,进行梁柱截面尺寸的估算,竖向荷载作用下(不考虑水平风荷载及地震作用下)的框架内力计算,楼板设计及配筋;梁柱的内力组合,配筋计算。框架内力计算方法为:恒载计算时采用弯矩二次分配法,活载计算时采用分层法逐层求得。而后,根据规范进行内力组合,然后进行梁柱的截面校核及配筋计算。最后,楼板按塑性计算双向板配筋。关键词: 框架;结构设计;内力计算;内力组合 abstract this topic is a offrce frame structure d
2、esign, structure design is mainly take a hinged frame, for four, two cross, the estimation of column section size, vertical load (don't consider level wind load and under seismic action) framework of internal force calculation, floor design and reinforcement; the combination of internal force of
3、 the beams, reinforcement calculation.internal force calculation for framework: constant load calculation by bending moment when secondary distribution method, live load calculation method obtained by stratified step by step. then, according to the standard "force combination, then check the be
4、ams cross section and reinforcement calculation. finally, according to the plastic floor slab reinforcement calculation two-way board.keywords: frames;structural design;calculating internal forces;the internal force combination.目录摘 要- 1 -abstract- 2 -目录- 3 -第一章:设计概述- 4 -1.1 工程概况:- 4 -1.2 建筑设计参考文献:-
5、4 -1.3 结构设计参考文献:- 4 -第二章 结构设计- 6 -2.1 结构选型- 6 -2.2 结构布置- 6 -2.3 基础选型- 7 -因用地无限制,未提供地质勘探报告,建议采用桩基础。桩基础具有承载力高、稳定性好、沉降量小而均匀、便于机械化施工、适应性强等特点。- 7 -第三章 板设计- 8 -3.1 楼面板的计算- 8 -第四章 一榀框架设计- 13 -4.1 框架梁柱、板、柱截面尺寸- 13 -4.2 荷载的计算- 14 -4.3. 梁、柱、墙重力荷载计算- 15 -4.4竖向荷载下框架荷载图- 16 -4.5 内力计算- 19 -4.6内力组合- 24 -第五章 截面设计与配
6、筋计算- 27 -5.1设计资料说明- 27 -5.2框架梁截面设计- 27 -5.2.1梁跨中截面设计- 27 -5.2.2梁支座截面设计- 28 -5.2.3斜截面受剪承载力计算- 29 -5.3框架柱截面设计- 30 -第一章:设计概述1.1 工程概况: 本食堂位于安庆市枞阳县横埠镇,用地等级未限制。结构形式:框架结构。设防烈度:不设抗震等级。建筑功能:能同时容纳700800人就餐;其它功能房间:设仓库、洗涤消毒间、熟食库及加工、生食库及加工、仓库、冷藏室、主食库、副食库、包点制作间及备餐区;楼梯间:2个、卫生间:2个、更衣室:1个;层数:3层;总建筑面积3697。1.2 建筑设计参考文
7、献: 1.2.1 设计原则:根据设计任务书要求,遵守设计规范,满足功能要求,力求设计的合理、美观、实用。 1.2.2 场地总平面见总图。 1.2.3 参考资料: 建筑设计部分:1中南建筑标准图集、中南结构标准图集2建筑设计资料集3建筑防火规范4其它建筑类规范5建筑工程制图、房屋建筑学。1.3 结构设计参考文献: 1.3.1 设计条件 (1)自然条件:基本风压值、基本雪压值按建筑结构荷载规范取用; (2)楼面和屋面活荷载按建筑结构荷载规范取用; (3)区域地震基本烈度7度; (4)工程地质资料另详。 1.3.2 设计任务要求 (1)确定结构和基础方案 (2)完成结构计算书一份 (3)完成施工图
8、1.3.3 参考资料 结构设计部分:1土木工程专业毕业设计指南2建筑结构设计手册3结构类教材4结构类规范 (1)建筑结构荷载规范gb50009-2001 (2)混凝土结构设计规范gb50010-2010 (3)建筑抗震设计规范gb50011-2010 5. 结构力学、混凝土结构设计、结构抗震设计等教材和参考书。第二章 结构设计2.1 结构选型钢筋混凝土结构是我国目前最常见的结构形式,它广泛地应用在建筑结构、桥梁结构、地下工程结构、水木结构和各式各样的特种结构中。有如下优点:l 强度高。有砖木结构相比,强度较高。在某些情况下,可代替钢结构,因而能节约钢材。l 耐久性好。混凝土包裹着钢筋,钢筋不易
9、锈蚀,与钢结构相比,钢筋混凝土结构几乎不用保养和维修。l 耐火性好。混凝土是不良导体,传热慢,只要混凝土有足够的厚度,遭受火灾时,钢筋在12h内不会达到软化的温度而导致结构破坏。l 可模性好。可根据设计需要浇成各种形状的构件和结构,适合作复杂的结构,如空心楼板、空间薄壳等。l 整体性好。现浇、钢筋混凝土结构具有较好的抗震、抗爆性能。l 易于就地取材。混凝土中的砂、石等材料分布广泛,能就地取材,不需要长途运输,因而造价低。 由于本工程为三层大跨度结构,出于功能、使用条件等方面考虑,因此采用框架混凝土结构2.2 结构布置 见下图2.3 基础选型 因用地无限制,未提供地质勘探报告,建议采用桩基础。桩
10、基础具有承载力高、稳定性好、沉降量小而均匀、便于机械化施工、适应性强等特点。 第三章 板设计3.1 楼面板的计算 楼面活荷载qk=2.5 kn/m2,板的自重加上面层、粉刷等,恒载gk=4.5 kn/m2,采用c20混凝土,板中钢筋采用hpb235钢。假设次梁截面宽200.边跨板端潜入柱120,板厚130。l2/l1=7500/3000=2.5<3,宜按双向板计算。 3.1.1 荷载设计值g=1.2×4.5=5.4 kn/m2q=1.4×2.5=3.5 kn/m2g+q/2=5.4+3.5/2=7.15 kn/m2q/2=3.5/2=1.75 kn/m2g+q=3.5
11、+5.4=8.9 kn/m2 3.1.2 计算跨度内跨:l0=4.5-0.2=4.3m边跨:l0=4.5-0.12-0.2/2+0.12/2=4.34m 3.1.3 弯距计算及截面设计由双向板塑性理论,根据不同支承情况,分为a b c d4种区格板, 假定选用8钢筋,则l01方向跨中截面h01=130-20=110mm,l02方向h02=130-30=100mm。混凝土等级: c20 fc=9.6n/mm2 ft=1.10n/mm2 ftk=1.54n/mm2 ec=3.0×104n/mm2 钢筋种类: hrb235 fy = 210 n/mm2 es = 2.0×105
12、n/mm2 最小配筋率: = 0.200% 纵向受拉钢筋合力点至近边距离: as = 20mm 保护层厚度: c = 10mms近似取0.95,则as=m/0.95h0fy a区格板l0y =4.5-0.2=4.3m,l0x=3.75-0.2=3.73 n= l0y /l0x =4.5/3.73=1.21,=1/n²=1/1.27²=0.69,取2采用弯起式配筋,跨中钢筋在距支座l0x /4处弯起一半,故得跨内及支座塑性绞线上的总弯矩为mx=( l0y- l0x /4)mx=3.3675mx my=3/4l0x mx=1.93mx mx=mx=l0ymx=8.6mx my=
13、my=l0xmx=5.1474mx带入基本公式,由于区格板a四周与梁相连,内力折减系数为0.8,由2mx+2my+mx+mx+my+my=p l0x²/12(3 l0y- l0x )2*3.3675mx+2*1.93mx+2*8.6m+2*5.1474mx=0.8*8.9*3.73²*(3*4.3-3.73)/12mx=1.987kn.m/mmy=mx=0.69*1.987=1.371 kn.m/mmx=mx=2*1.987=3.974 kn.m/mmy=my=2*1.371=2.742 kn.m/m b区格板l0y =4.5-0.2=4.3m,l0x=3.75-0.2-0
14、.12+0.12/2=3.49m ,由于b区格板为三边连续一边简支,无边梁,内力不作折减,又由于长边支座弯矩为已知,mx=3.974 kn.m/m mx=( l0y- l0x /4)mx=3.4275mx my=3/4l0x mx=1.8061mx mx=3.974*3.49=13.8693kn.m,mx=0 my=my=l0xmx=4.8162mx带入基本公式,由2mx+2my+mx+mx+my+my=p l0x²/12(3 l0y- l0x )2*3.4275mx+2*1.8061mx+13.8693+2*4.8162mx=8.9*3.49²*(3*4.3-3.49)/
15、12mx=3.5392kn.m/mmy=mx=0.69*3.5392=2.4421 kn.m/mmx=mx=2*3.5392=7.0784 kn.m/mmy=my=2*1.55=4.8842 kn.m/m c区格板l0y =4.5-0.2-0.12+0.12/2=4.24m,l0x=3.75-0.2=3.55m 由于b区格板为三边连续一边简支,无边梁,内力不作折减,又由于长边支座弯矩为已知, my=2.742kn.m/m mx=( l0y- l0x /4)mx=3.3525mx my=3/4l0x mx=1.8371mx mx=l0ymx=8.48mx my=my*4.24=11.6261 k
16、n.m my=0带入基本公式,由2mx+2my+mx+mx+my+my=p l0x²/12(3 l0y- l0x )2*3.3525mx+2*1.8371mx+2*8.48mx+11.6261=8.9*3.55²*(3*4.24-3.55)/12mx=2.7098kn.m/mmy=mx=0.69*2.7098=1.8698 kn.m/mmx=mx=2*2.7098=5.4197 kn.m/mmy=my=2*1.8698=3.7396 kn.m/m d区格板(计算过程略)mx=4.1384 kn.m/mmy=2.1416 kn.m/m配筋计算:各区格板跨内及支座弯矩已求得,取
17、截面有效高度h0x=110mm.h02=100mm.即可按近似as=m/0.95fyh0计算钢筋截面面积,计算结果,配筋图下详。双向板配筋计算截面m/(kn*m)h0/mmas/mm²选配钢筋适配面积/mm²跨中a区格lox方向l0y方向1.9871.37111010090.5468.728200252b区格lox方向l0y方向3.53922.4421110100161.28122.418200252c区格lox方向l0y方向2.70981.8698110100123.4893.728200252d区格lox方向l0y方向4.13842.1416110100188.4210
18、7.358200252支座a-b3.974110181.098200252a-c2.742110124.958200252b-d4.8842110222.578200252c-d5.4197110246.9782002523.1.4楼板布筋图楼板负筋长度?第四章 一榀框架设计4.1 框架梁柱、板、柱截面尺寸计算一榀框架,以号轴线为例,计算框架在内力的作用下,弯矩、轴力、剪力。 4.1.1 框架梁: 主粱:h0=(1/81/18)l0=(1/81/18)×9000=1125500mm 取h0=700mm b0=(1/21/4)h0=(1/21/4)×700=350175mm
19、取b0=300mm 次粱:h0=(1/121/18)l0=(1/121/18)×9000=750500mm 取h0=500mm b0=(1/21/4)h0=(1/21/4)×500=250125mm 取b0=250mm11粱截面初步设计:主粱均为300×700mm,次粱均为:250×500mm 4.1.2 楼(屋)面板: 板厚:h=(1/301/40)l0=(1/301/40)*500=167125mm 取h=130mm 4.1.3 框架柱: 柱子的截面尺寸:按层高确定: 底层层高h =4500 mmb c=(1/12-1/18)×h =375
20、250 mm按轴压比确定:可根据式估算。各层的平均荷载设计值近似取14 kn/m2,柱的负载面积(从属面积)为7.5×9m2。由公式可得第一层柱截面面积为:acn/fc1.2*×14×7.5×9*3×103/11.9=285882.3529mm2 所以b=h535mm,柱截面取b=h=600mm 4.1.4框架梁柱的线刚度确定 对于与中框梁取i=2i0 梁: ei/l=3.0*107*2*1/12*0.3*0.64/9=3.6*104kn.m 柱: i底柱= ei/l=3.0*107*2*1/12*0.64/5.6=5.8*104kn.m i余
21、柱=3.0*107*2*1/12*0.64/4.5=7.2*104kn.m 令i余柱=1.0,则其余各杆的相对线刚度为 i梁=0.5; i底柱=0.84.2 荷载的计算 4.2.1 屋面恒载20厚水泥砂浆找平层 150厚水泥蛭石保温层 130厚钢筋混凝土板 20厚石灰砂浆 合计 4.2.2 楼面恒载:瓷砖地面(包括水泥粗砂打底) 130厚钢筋混凝土板 20厚水泥砂浆 合计 4.2.3 屋面活载: 屋面为上人屋面,查建筑结构荷载规范得均布荷载标准值为2.0kn/m2 4.2.4楼面活载:查建筑结构荷载规范楼面均布活载中:餐厅为2.5kn/m2,走廊、门庭、楼梯为2.5kn/m2。4.3. 梁、柱
22、、墙重力荷载计算梁、柱可根据截面尺寸、材料容重及粉刷等计算出单位长度上的重力荷载。具体计算过程从略,计算结果见表3所示:表4 梁、柱恒荷载标准值构件b(m)h(m)(kn.m-3)(kn.m-1)g(kn/m)主梁0.30.7-0.12250.3404.69次梁0.250.5-0.12250.2553.10513层柱0.60.6250.349.34注:1)表中为10mm厚水泥砂浆抹灰的线密度; 2)梁长度取计算长度;柱高取层高。内外墙都采用砼空心砌块,外墙厚均240mm,无内墙。墙体抹灰近似按加厚墙体考虑其重量。单位面积墙体自重: 外墙: 0.29×18*2.1=10.962kn/m
23、 女儿墙:0.24*1.1*18+25*0.1*0.24+(1.2*2+0.24)*0.5=6.67 kn/m4.4竖向荷载下框架荷载图(1)ab轴间框架梁屋面板荷载传递:恒载:4.74*4.5*5/8*2=4.74*=26.6625kn/m活载:2.0*4.5*5/8*2=11.25kn/m楼面板荷载传递:恒载:4.2*4.5*5/8*2=23.625kn/m活载:2.5*4.5*5/8*2=14.0625kn/m梁自重:4.69kn/mab轴间框架梁均布荷载为:屋面梁:恒载=梁自重+板传荷载 =4.69+26.6625=31.3525kn/m 活载=板传荷载=11.25kn/m楼面梁:恒载
24、=梁自重+板传荷载 =4.69+23.625=28.315kn/m 活载=板传荷载=14.0625kn/m(2)bc轴间框架梁屋面板荷载传递:恒载:4.74*4.5*5/8*2=4.74*=26.6625kn/m活载:2.0*4.5*5/8*2=11.25kn/m楼面板荷载传递:恒载:4.2*4.5*5/8*2=23.625kn/m活载:2.5*4.5*5/8*2=14.0625kn/m梁自重:4.69kn/mbc轴间框架梁均布荷载为:屋面梁:恒载=梁自重+板传荷载 =4.69+26.6625=31.3525kn/m 活载=板传荷载=11.25kn/m楼面梁:恒载=梁自重+板传荷载 =4.69
25、+23.625=28.315kn/m 活载=板传荷载=14.0625kn/m(3)cd轴间框架梁屋面板荷载传递:恒载:4.74*4.5*5/8*2=4.74*=26.6625kn/m活载:2.0*4.5*5/8*2=11.25kn/m楼面板荷载传递:恒载:4.2*4.5*5/8*2=23.625kn/m活载:2.5*4.5*5/8*2=14.0625kn/m梁自重:4.69kn/mcd轴间框架梁均布荷载为:屋面梁:恒载=梁自重+板传荷载 =4.69+26.6625=31.3525kn/m 活载=板传荷载=11.25kn/m楼面梁:恒载=梁自重+板传荷载 =4.69+23.625=28.315k
26、n/m 活载=板传荷载=14.0625kn/m(4)a、d轴柱纵向集中荷载的计算顶柱恒荷载=女儿墙+梁自重+板传荷载=4.69*(7.5-0.6)+6.67*7.5+7.5*26.6625/2=182.37kn顶柱活荷载=11.25/2*7.5=42.1875kn标准层恒荷载=墙自重+梁自重+板传荷载=10.962*(7.5-0.6)+4.69*(7.5-0.6)+23.625/2*7.5=196.56255kn标准层活荷载=板传荷载=14.0625*7.5=105.46875kn基础顶面恒载=底层外墙自重+基础梁自重=10.962*(7.5-0.6)+4.69*(7.5-0.6)=107.9
27、988kn(5)b、c轴柱纵向集中荷载的计算顶层柱恒荷载=梁自重+板传荷载=4.69*(7.5-0.6)+7.5*31.3525/2=149.9329kn顶层柱活荷载=板传荷载=11.25/2*7.5=42.1875kn标准层恒荷载=梁自重+板传荷载=4.69*(7.5-0.6)+28.315/2*7.5=138.5235kn标准层活荷载=板传荷载=28.315/2*7.5=106.1625kn基础顶面恒载=基础梁自重=4.69*(7.5-0.6)=32.361kn框架在竖向荷载受力总图如下4.5 内力计算 4.5.1梁端固定弯矩计算: 恒载:屋面:ma3=mb3=-1*/12gl2=-1/1
28、2*31.35*92=-211.6kn.m md3=mc3=211.6 kn.m 楼面:ma2=ma1=mb2=mb1=-1*/12gl2=-1/12*28.315*92=-191.1 kn.m mc1=mc2=md1=md2=191.1kn.m活载:屋面: ma3=mb3=-1/12*ql2=-1/12*11.25*92=-75.9kn.m mc3=md3=75.9kn.m 楼面: ma2=mb2=ma1=mb1=-1/12*14.06*92=-94.9kn.m mc2=md2=mc1=md1=94.9kn.m 竖向均布恒载作用下的框架弯矩图竖向均布活荷载作用下的框架内力计算方法同上,结果见
29、图。活载作用下弯矩图活荷载作用下的弯矩图 4.5.2 梁端剪力和轴力计算 梁端剪力 柱轴力 具体计算结果见表。 恒载作用下a梁端剪力计算 层号331.359141.18.5132.6149.6228.329127.45.0122.4132.4128.329127.45.0122.4132.4 恒载作用下b梁端剪力计算层号331.359141.10141.1141.1228.329127.40127.4127.4128.329127.40127.4127.4 活载作用下a梁端剪力计算层号311.25950.63.754.346.9214.06963.32.960.466.2114.06963.3
30、2.960.466.2 活载作用下b梁端剪力计算层号311.25950.6050.650.6214.06963.3063.363.3114.06963.3063.363.3恒载作用下的剪力和轴力层次总剪力柱轴力ab跨bc跨a柱b柱3132.6149.6141.8328370290.7332.82122.4132.4127.4693.9735.9656.8698.81122.4132.4127.41429.81482.11355.61407.9 活载作用下的剪力和轴力层次总剪力柱轴力ab跨bc跨a柱b柱346.954.350.689.189.1260.466.263.3165.9165.9160
31、.466.263.3165.9165.94.6内力组合荷载组合时考虑2种荷载组合形式:(1)恒荷载+活荷载、(2)恒荷载+活荷载。具体组合见表:横梁内力组合表层次位置内力内力组合恒载活载1.2+1.41.35+1.03am-144.1-51.7-245.3-246.235v132.654.3235.14233.31abm125.9745.36214.668215.4195b左m-220.6-85.4-384.28-383.21v149.646.9245.18248.86b右m-238.8-79.1-397.3-401.48v141.150.6240.16241.085bem96.828.515
32、6.06159.182am-74.6-76.7-196.9-177.41v122.460.4231.44225.64abm113.652.4209.68205.76b左m-197.5-103.2-381.48-369.825v132.466.2251.56244.94b右m-207-96.6-383.64-376.05v127.463.3241.5235.29bem91.339.2164.44162.4551am-149.6-75.7-285.5-277.66v122.460.4231.44225.64abm120.352.8218.28215.205b左m-174-103.4-353.56-
33、338.3v132.466.2251.56244.94b右m-187.4-96.7-360.26-349.69v127.463.3241.5235.29bem101.440177.68176.89框架柱内力计算层次位置内力荷载类型内力组合恒载活载1.2+1.41.35+1.03a上m144.151.7245.3246.235n32889.1518.34531.9a下m-76.4-38.4-145.44-141.54n37089.1568.74588.6b上m-18.1-6.3-30.54-30.735n290.789.1473.58481.545b下m6.43.312.311.94n332.8
34、89.1524.1538.382a上m76.438.4145.44141.54n693.9165.91064.941102.665a下m-83.1-41.7-158.1-153.885n735.9165.91115.341159.365b上m-8-1.02n656.8165.91020.421052.58b下m7.43.814.213.79n698.8165.91070.821109.281a上m66.533.3126.42123.075n1429.8165.91948.022096.13a下m-33.1-16.7-63.1-61.385n1482.1165.92010.78
35、2166.735b上m-5.9-2.9-11.14-10.865n1355.6165.91858.981995.96b下m5n1407.9165.91921.742066.565注:表中m以左侧受拉为正,单位为kn.m,n以受压为正,单位为kn。第五章 截面设计与配筋计算5.1设计资料说明 框架梁的正截面及斜截面的配筋计算可按混凝土结构设计规范(gb 50010-2010)中钢筋混凝土受弯构件的配筋计算方法计算。混凝土强度 c25 钢筋强度 hpb235 hrb335 5.2框架梁截面设计楼板与框架整体浇灌,梁的跨中应按t形截面计算,支座处按矩形截面计算。以a3梁为例计算其
36、跨中及支座处的配筋计算,为便于比较和阅读,可将配筋计算过程列成表格。下表分别为框架梁的正截面配筋计算表和斜截面配筋计算表。 5.2.1梁跨中截面设计翼缘计算跨度当按跨度考虑时,bf=l0/3=(9000-600)/3=2800mm按梁间距考虑时,bf=b+sn=300+9000-2*600=8100mm按翼缘厚度考虑时,hf/h0=130/635=0.2>0.1,h0=700-35=665mm此种情况不起控制作用,故取bf=2800mm。梁内纵向钢筋选用hrb335级钢筋(),。下部跨间截面按单筋t形截面计算。因为1*fc*bf*hf(h0-hf/2)=1.0*11.9*2800*130
37、*(665-130/2)=2512.33kn.m>215.42kn.m属于第一类t形截面。截面抵抗矩系数 s=m/(1*fc*bf*h02)=215.42*106/(1.0*11.9*2800*665)=0.0156 相对界限受压区高度 =1-sqrt(1-0.0156*2)=0.0157最小配筋率 as=1*fc*bf*h0/fy=1.0*11.9*2800*0.0157*665/300=1159.6mm2>minbh=420mm2实配钢筋 4b20(as=1256mm2),配筋率为=1256/(300*700)=0.60% 5.2.2梁支座截面设计以3层梁支座截面设计为例。 s
38、=m/(1*fc*b*h02)=246.2/(1.0*11.9*300*6652)=0.156=1-sqrt(1-0.0156*2)=0.170as=1*fc*b*h0/fy=1.0*11.9*300*0.156*665/300=1234.5>minbh=420mm2实配钢筋 4b20(as=1256mm2),配筋率为=1256/(300*700)=0.60%其余梁的正截面配筋计算见表框架梁的正截面配筋计算表正截面配筋计算层次位置m(kn.m)sas实配钢筋实配面积配筋率%3a246.240.1560 0.1705 1349.3213 4b2215200.7238 ab215.420.1
39、365 0.1473 1165.6488 4b2215200.7238 b左384.280.2434 0.2836 2244.5258 6b2222811.0862 b右401.480.2543 0.2990 2366.1821 6b2222811.0862 bc159.180.1008 0.1065 842.7714 3b2211400.5429 2a196.90.1247 0.1337 1057.6449 4b2215200.7238 ab209.680.1328 0.1430 1131.9907 4b2215200.7238 b左369.830.2343 0.2710 2144.3029
40、 6b2222811.0862 b右383.640.2430 0.2831 2240.0494 6b2222811.0862 bc164.440.1042 0.1102 872.3418 3b2211400.5429 1a285.50.1808 0.2011 1591.0151 4b2215200.7238 ab218.280.1383 0.1494 1182.4821 4b2215200.7238 b左353.560.2240 0.2570 2033.5009 6b2222811.0862 b右360.260.2282 0.2627 2078.8744 6b2222811.0862 bc17
41、7.680.1125 0.1197 947.3292 3b2211400.5429 5.2.3斜截面受剪承载力计算(1)复核截面尺寸 vmax=235.14kn hw/b=665/300=2.2<4.00.25c*fc*b*h0=0.25*1.0*11.9*300*665=593.5kn>vmax 截面尺寸满足要求。(2)确定是否按计算配置箍筋0.7ft*b*h0=0.7*1.27*300*665=177.36kn<vmax 需按计算配置箍筋。(3) 只配箍筋的计算nasv1/s=(vmax-0.7ft*b*h0)/1.25fyv*h0=(235.4-0.7*1.27*300
42、*665)/1.25*210*665=0.332(mm2/mm)选用双肢箍筋2,箍筋直径,代入上式得:s= nasv1/s=2*50.3/0.332=304.8选取 验算最小配箍率:sv=nasv1/bs=2*50.3/300/200=16.7%>0.24*ft/fyv0.24*1.27/210=1.45%,满足要求。其余梁斜截面的配筋计算过程见表。表6.2 框架梁的斜截面配筋计算表层次位置v0.25c*fc*b*h00.7ft*b*h0asv/s双肢箍8间距适配间距3a235.14593.5177.40.33 304.14 200b左248.86593.5177.40.41 245.7
43、5 200b右241.08593.5177.40.36 275.77 2002a231.44593.5177.40.31 324.96 200b左251.56593.5177.40.42 236.80 200b右241.5593.5177.40.37 273.96 2001a231.44593.5177.40.31 324.96 200b左251.56593.5177.40.42 236.80 200b右241.5593.5177.40.37 273.96 2005.3框架柱截面设计以b轴顶层柱为例进行柱的配筋计算,为便于比较和阅读,可将配筋计算过程列成表格。 5.3.1轴压比验算顶层柱 2166.7 kn轴压比 n=nmax/(fc*ac)=2166.7/(14.3*600*560)=0.45<1.0,满足要求则a轴柱的轴压比满足要求。 5.3.2 正截面受弯承载力计算 柱的同一截面分别承受正反弯矩,故采用对称配筋 b轴柱: nb=1*fc*b*h0*b=14.3*600*560*0.550=2642.6kn一层:从柱的内力组合表可见,n<nb,为小偏心;选用n大m小的组合,最不利组合为n=2166.7kn,m=61.4kn柱计算长度 l0=1.0h=1.0*4.5=4.5ml0/h=4500/600=9e0=m/n=61.
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。