已阅读5页,还剩11页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
BRITISH STANDARD BS EN 50266-2-2:2001 Incorporating Corrigendum No. 1 Common test methods for cables under fire conditions Test for vertical flame spread of vertically-mounted bunched wires or cables Part 2-2: Procedures Category A The European Standard EN 50266-2-2:2001 has the status of a British Standard ICS 13.220.40; 29.060.20 ? Copyright European Committee for Electrotechnical Standardization Provided by IHS under license with CENELEC Not for ResaleNo reproduction or networking permitted without license from IHS -,- BS EN 50266-2-2:2001 This British Standard, having been prepared under the direction of the Electrotechnical Sector Committee, was published under the authority of the Standards Committee and comes into effect on 15 August 2001 BSI 30 September 2002 ISBN 0 580 37924 8 National foreword This British Standard is the official English language version of EN 50266-2-2:2001, including Corrigendum March 2002. Together with BS EN 50266-1, BS EN 50266-2-1, BS EN 50266-2-3; BS EN 50266-2-4 and BS EN 50266-2-5, it supersedes BS 4066-3:1994 which is withdrawn. BS 4066-3: 1994 had a number of test categories. All these test categories are retained in BS EN 50266, and can be found in the respective parts of the new publication as follows: The UK participation in its preparation was entrusted by Technical Committee GEL/20, Electric cables, to Subcommittee GEL/20/3, Insulation and sheath, which has the responsibility to: A list of organizations represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Test category in BS 4066-3Equivalent part of BS EN 50266a A F/RBS EN 50266-2-1 ABS EN 50266-2-2 BBS EN 50266-2-3 CBS EN 50266-2-4 BS EN 50266-2-5b a In all cases, the particular part is to be used in conjunction with BS EN 50266-1, which describes the test apparatus. b This part describes Category D, which did not form part of BS 4066-3. aid enquirers to understand the text; present to the responsible European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 12, an inside back cover and a back cover. The BSI copyright date displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. DateComments 13849 Corrigendum No. 1 30 September 2002Change to date of withdrawal in EN foreword Copyright European Committee for Electrotechnical Standardization Provided by IHS under license with CENELEC Not for ResaleNo reproduction or networking permitted without license from IHS -,- EUROPEAN STANDARDEN 50266-2-2 NORME EUROPENNE EUROPISCHE NORMFebruary 2001 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2001 CENELEC -All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50266-2-2:2001 E ICS 13.220.40; 29.020; 29.060.20Supersedes HD 405.3 S1:1993 Incorporating corrigendum March 2002 English version Common test methods for cables under fire conditions - Test for vertical flame spread of vertically-mounted bunched wires or cables Part 2-2: Procedures - Category A Mthodes dessai communes aux cbles soumis au feu - Essai de propagation verticale de la flamme des fils ou cbles en nappes en position verticale Partie 2-2: Procdures - Catgorie A Allgemeine Prfverfahren fr Kabel und isolierten Leitungen im Brandfall - Prfung der senkrechten Flammenausbreitung von senkrecht angeordneten Bndeln von Kabeln und isolierte Leitungen Teil 2-2: Prfverfahren - Prfart A This European Standard was approved by CENELEC on 2000-08-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. Copyright European Committee for Electrotechnical Standardization Provided by IHS under license with CENELEC Not for ResaleNo reproduction or networking permitted without license from IHS -,- EN 50266-2-2:2001- 2 - Foreword This European Standard was prepared by Working Group 10 of the Technical Committee CENELEC TC 20, Electric cables. When used in conjunction with EN 50266-1 this European Standard supersedes HD 405.3 S1 in respect of test category A. All pre-existing categories of test from HD 405.3 S1 have been retained and updated in the different parts 2. A new category (category D) has been added to cater for testing at very low non-metallic volumes. The description of the apparatus given in EN 50266-1 updates that in HD 405.3 S1. The text of the draft was submitted to the Unique Acceptance procedure and was approved by CENELEC as EN 50266-2-2 on 2000-08-01. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement(dop)2001-08-01 latest date by which the national standards conflicting with the EN have to be withdrawn(dow)2002-08-01 Annexes designated normative are part of the body of the standard. Annexes designated informative are given for information only. In this standard, annex A is normative and annex B is informative. _ Copyright European Committee for Electrotechnical Standardization Provided by IHS under license with CENELEC Not for ResaleNo reproduction or networking permitted without license from IHS -,- - 3 -EN 50266-2-2:2001 Contents Page Introduction4 1 Scope5 2 Normative references.5 3 Definitions.5 3.1 Ignition source5 3.2 Char5 3.3 Flame spread .5 4 Test apparatus6 4.1 General.6 4.2 Ignition source6 5 Test procedure .6 5.1 Test sample6 5.2 Determination of number of test pieces .6 5.3 Mounting of the test sample .7 5.4 Flame application time .7 6 Evaluation of test results.8 7 Performance requirements.8 8 Retest procedure8 9 Test report 8 Annex A (normative) Guidance on cable selection for type approval testing 11 Annex B (informative) Recommended performance requirements.12 Copyright European Committee for Electrotechnical Standardization Provided by IHS under license with CENELEC Not for ResaleNo reproduction or networking permitted without license from IHS -,- EN 50266-2-2:2001- 4 - Introduction Methods of test for flame spread characteristics for a single vertical insulated wire or cable are given in EN 50265, but it cannot be assumed that, because a cable or wire meets the requirements of that standard, a vertical bunch of similar cables or wires will behave in a similar manner. This is because flame spread along a vertical bunch of cables depends on a number of features, such as: a) the volume of combustible material exposed to the fire and to any flame which may be produced by the combustion of the cables; b) the geometrical configuration of the cables and their relationship to an enclosure; c) the temperature at which it is possible to ignite the gases emitted from the cables; d) the quantity of combustible gas released from the cables for a given temperature rise; e) the volume of air passing through the cable installation; f) the construction of the cable, e.g. armoured or unarmoured, multi or single core. All of the foregoing assume that the cables are able to be ignited when involved in an external fire. EN 50266 gives details, in various parts, of a test where a number of cables are bunched together to form various test sample installations. For easier use and differentiation of the apparatus and the various test categories, the parts are designated as follows: Part 1Apparatus Part 2-1Category A F/R Part 2-2Category A Part 2-3Category B Part 2-4Category C Part 2-5Category D Parts from 2-1 onwards define the various categories and the relevant procedures. The categories are distinguished by test duration, the volume of non-metallic material of the test sample and the method of mounting the sample for the test. In all categories, cables having at least one conductor of cross-sectional area greater than 35 mm are tested in a spaced configuration, whereas cables of conductor cross-sectional area of 35 mm or smaller are tested in a touching configuration. The categories are not necessarily related to different safety levels in actual cable installations. The actual installed configuration of the cables may be a major determinant in the level of flame spread occurring in an actual fire. The method of mounting described as category A F/R (part 2-1) is intended for special cable designs used in particular installations. Categories A, B, C and D (parts 2-2 to 2-5 respectively) are for general use where different non-metallic volumes are applicable. Additional categories, especially to cover the use of small diameter communication cables in closely bunched configurations, will be further considered when more data is available. Copyright European Committee for Electrotechnical Standardization Provided by IHS under license with CENELEC Not for ResaleNo reproduction or networking permitted without license from IHS -,- - 5 -EN 50266-2-2:2001 1Scope EN 50266 specifies methods of test for the assessment of vertical flame spread of vertically-mounted bunched wires or cables, electric or optical, under defined conditions. NOTEFor the purpose of this standard the term electric wire or cable covers all insulated metallic conductor cables used for the conveyance of energy or signals. The test is intended for type approval testing. The requirements for the selection of cables for testing are given in annex A. The flame spread is measured as the extent of damage of the cable sample. This procedure may be used to demonstrate the cables ability to limit flame spread. This Part 2-2 covers category A and relates to cables installed on the test ladder to achieve a nominal total volume of non-metallic material of 7 litres per metre of test sample. The flame application time is 40 min. The method of mounting uses the front of the ladder, a standard or wide ladder being used for cables having a conductor cross-section greater than 35 mm according to the number of test pieces required, and a standard ladder for conductor cross-sections 35 mm and smaller. The category is intended for general use where high volumes of non-metallic material are required to be evaluated. A recommended performance requirement is given in annex B. 2Normative references This European Standard incorporates by dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision. For undated references the latest edition of the publication referred to applies. EN 50266-1Common test methods for cables under fire conditions - Test for vertical flame spread of vertically-mounted bunched wires or cables - Part 1 : Apparatus EN 60695-4Fire hazard testing - Part 4: Terminology concerning fire tests EN 60811-1-3Insulating and sheathing materials of electric cables - Common test methods Part 1- 3: General application - Methods for determining the density - Water absorption tests - Shrinkage test 3Definitions For the purpose of EN 50266-2-2 the following definitions apply. Definitions are taken from EN 60695-4. 3.1 ignition source a source of energy that initiates combustion 3.2 char carbonaceous residue resulting from pyrolysis or incomplete combustion 3.3 flame spread propagation of a flame front Copyright European Committee for Electrotechnical Standardization Provided by IHS under license with CENELEC Not for ResaleNo reproduction or networking permitted without license from IHS -,- EN 50266-2-2:2001- 6 - 4Test apparatus 4.1General The apparatus specified in EN 50266-1 shall be used. 4.2Ignition source The ignition source shall be one or two ribbon-type propane gas burners as specified in EN 50266-1. A single burner shall be used with the standard ladder and two burners with the wide ladder. 5Test procedure 5.1Test sample The test sample shall comprise a number of test pieces of cable from the same production length, each having a minimum length of 3,5 m. The total number of test pieces in the test sample shall be that number required to provide a nominal total volume of non-metallic material of 7 litres per metre of test sample. The test sample shall be chosen within the limitations given in annex A. The test pieces forming the test sample shall be conditioned at a temperature of (20 10)C for at least 16 h before commencing the test. The test pieces shall be dry. 5.2Determination of the number of test pieces In order to calculate the appropriate number of test pieces, it is necessary to determine the volume per metre of non-metallic material of one test piece. A length of cable which shall not be less than 0,3 m long is carefully cut to ensure that the surfaces are at right angles to the cable axis, thus enabling precise measurements of its length. The density of each non-metallic component (including cellular material) shall be measured in an appropriate way, e.g. clause 8 of EN 60811-1-3, in order to obtain values expressed to the second decimal place. Each non-metallic material Ci shall be removed from the test piece and weighed. Any non-metallic material making up less than 5 % of the total non-metallic mass of the test piece shall be assumed to have a density of 1,0 kg/dm. Where semi-conducting screens cannot be removed from the insulating material, the components may be considered as one for the purpose of measuring their mass and density. The volume Vi (litres per metre of cable) of each non-metallic material Ci is calculated as follows: Vi = l M ?i i where Miis the mass of the component Ci (kg) ?iis the density of the component Ci (kg/dm) lis the length of the test piece of cable (m) The total volume, V, of the non-metallic materials contained in one metre of cable is equal to the sum of the individual volumes V1, V2, etc. Copyright European Committee for Electrotechnical Standardization Provided by IHS under license with CENELEC Not for ResaleNo reproduction or networking permitted without license from IHS -,- - 7 -EN 50266-2-2:2001 The closest integer (0,5 and above corresponding to 1) of the number of test pieces to be mounted is obtained by dividing the volume per metre specified in 5.1 of this part by the total volume, V, of non-metallic material per metre of cable. 5.3Mounting of the test sample 5.3.1Cables having at least one conductor above 35 mm For cables having at least one conductor with a cross-section exceeding 35 mm, each test piece shall be attached individually to each rung of the ladder by means of metal wire (steel or copper). For cables up to and including 50 mm diameter use wire between 0,5 mm and 1,0 mm in diameter. For cables above 50 mm diameter use wire between 1,0 mm and 1,5 mm in diameter. Test pieces shall be attached to the front of the ladder in a single layer with a space between each test piece of 0,5 x the cable diameter but not exceeding 20 mm. The ladder may be either standard or wide depending on whichever is necessary to ensure that there shall be a minimum distance of 50 mm between the edge of the test sample and the inside of the ladder uprights. The maximum width of the test sample for the standard ladder shall be 300 mm and for the wide ladder 600 mm (see Figures 1 and 2). When mounting the test pieces, the first test piece shall be positioned approximately in the centre of the ladder and further test pieces added on either side so that the whole array of test pieces is approximately centred on the ladder. 5.3.2Cables having conductors of 35 mm and below For cables having all conductors with cross-sections of 35 mm or smaller, each test piece shall be attached, either individually or as part of an array, to each rung of the ladder by means of metal wire (steel or copper) between 0,5 mm and 1,0 mm in diameter. Test pieces shall be attached to the front of the standard ladder in touching formation in one or more layers up to a maximum total width of 300 mm. There shall be a
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 个人安全防护用品管理制度(二篇)
- 供应部业务主管安全生产岗位责任制范文(2篇)
- 2024年企业员工五一劳动节演讲稿例文(3篇)
- 2021年10月广西玉林市玉州区重点产业招商工作专班人员公开招聘模拟卷(一)
- 启动仪式活动方案样本(3篇)
- 2024年高考动员会校长发言稿(3篇)
- 2024年公司年会庆典致辞(6篇)
- 厂内机动车辆安全管理制度样本(4篇)
- 干吸岗位操作规程(3篇)
- 2024年幼儿园中班保育员工作计划样本(2篇)
- 松下电器(中国)焊接学校——焊接技术
- 《肺动脉高压护理》PPT课件.ppt
- 青少年特发性脊柱侧弯症中医诊疗方案4
- 研发系统积分考核管理办法
- 河堤工程岩土工程勘察报告
- 完整版水稳自评报告
- 《小儿推拿》PPT课件(完整版)
- 幼儿园区域材料投放明细(修改版)
- 人教版五年级上册《练习十七》数学教案_1
- 浅谈汽车智能化焊装生产线的安装与调试
- 顶管穿越铁路施工技术措施
评论
0/150
提交评论