LXXXVI楼盖结构设计设计依据楼面板厚为h=100mm,根据不同的支承情况,梁把楼盖分为B1~B8八种区格板。如下图:楼面板区格划分图荷载设计值计算永久荷载分项系数取1.3;可变荷载分项系数取1.5(1)楼面:(2)走廊:(3)卫生间:弯矩计算1、B1区格板:混凝土泊松比取0.2,l01/l02=3.60/7.20=0.5,两边固定两边简支,查表得,m1=0.0559,m2=0.0079,m1'=-0.1179,m2'=-0.0786;周边简支时,查表得,m1=0.0965,m2=0.0174。m1=(0.0559+0.2×0.0079)×6.203×3.62+(0.0965+0.2×0.0174)×1.50×3.62=6.56kN·mm2=(0.0079×0.2+0.0559)×6.203×3.62+(0.0174+0.2×0.0965)×1.50×3.62=2.25kN·mm1'=-0.1179×7.703×3.62=-11.77kN·mm2'=-0.0786×7.703×3.62=-7.85kN·m2、B2区格板:混凝土泊松比取0.2,l01/l02=3.60/7.20=0.5,三边固定一边简支,查表得,m1=0.0408,m2=0.0028,m1'=-0.0836,m2'=-0.0569;周边简支时,查表得,m1=0.0965,m2=0.0174。m1=(0.0408+0.2×0.0028)×6.203×3.62+(0.0965+0.2×0.0174)×1.50×3.62=5.27kN·mm2=(0.0028×0.2+0.0408)×6.203×3.62+(0.0174+0.2×0.0965)×1.50×3.62=1.59kN·mm1'=-0.0836×7.703×3.62=-8.35kN·mm2'=-0.0569×7.703×3.62=-5.68kN·m3、B3区格板:混凝土泊松比取0.2,l01/l02=3.00/3.60=0.8333,三边固定一边简支,查表得,m1=0.0296,m2=0.0133,m1'=-0.0703,m2'=-0.0568;周边简支时,查表得,m1=0.0524,m2=0.0343。m1=(0.0296+0.2×0.0133)×6.578×3.62+(0.0524+0.2×0.0343)×1.875×3.62=2.91kN·mm2=(0.0133×0.2+0.0296)×6.578×3.62+(0.0343+0.2×0.0524)×1.875×3.62=1.90kN·mm1'=-0.0703×8.453×3.62=-5.35kN·mm2'=-0.0568×8.453×3.62=-4.32kN·m4、B4区格板:混凝土泊松比取0.2,l01/l02=3.00/3.60=0.8333,四边固定,查表得,m1=0.0254,m2=0.0152,m1'=-0.0639,m2'=-0.0554;周边简支时,查表得,m1=0.0524,m2=0.0343。m1=(0.0254+0.2×0.0152)×6.578×3.62+(0.0524+0.2×0.0343)×1.875×3.62=2.69kN·mm2=(0.0152×0.2+0.0254)×6.578×3.62+(0.0343+0.2×0.0524)×1.875×3.62=1.96kN·mm1'=-0.0639×8.453×3.62=-4.86kN·mm2'=-0.0554×8.453×3.62=-4.21kN·m5、B5区格板:混凝土泊松比取0.2,l01/l02=3.00/3.60=0.8333,三边固定一边简支,查表得,m1=0.0223,m2=0.0267,m1'=-0.0691,m2'=-0.0731;周边简支时,查表得,m1=0.0524,m2=0.0343。m1=(0.0223+0.2×0.0267)×6.578×3.62+(0.0524+0.2×0.0343)×1.875×3.62=2.34kN·mm2=(0.0267×0.2+0.0223)×6.578×3.62+(0.0343+0.2×0.0524)×1.875×3.62=2.34kN·mm1'=-0.0691×8.453×3.62=-4.79kN·mm2'=-0.0731×8.453×3.62=-5.07kN·m6、B6区格板:混凝土泊松比取0.2,l01/l02=3.6/4.8=0.75,两边固定两边简支,查表得,m1=0.039,m2=0.189,m1'=-0.0938,m2'=-0.076;周边简支时,查表得,m1=0.062,m2=0.0317。m1=(0.039+0.2×0.189)×8.17×3.62+(0.062+0.2×0.0317)×1.875×3.62=6.19kN·mm2=(0.189×0.2+0.039)×8.17×3.62+(0.0317+0.2×0.062)×1.875×3.62=3.90kN·mm1'=-0.0938×10.04×3.62=-12.21kN·mm2'=-0.076×10.04×3.62=-9.89kN·m7、B7区格板:混凝土泊松比取0.2,l01/l02=2.4/3.6=0.6667,三边固定一边简支,查表得,m1=0.362,m2=0.082,m1'=-0.0789,m2'=-0.0572;周边简支时,查表得,m1=0.0728,m2=0.0279。m1=(0.362+0.2×0.082)×8.17×2.42+(0.0728+0.2×0.0279)×1.875×2.42=2.63kN·mm2=(0.082×0.2+0.362)×8.17×2.42+(0.0279+0.2×0.0728)×1.875×2.42=1.18kN·mm1'=-0.0789×10.04×2.42=-4.56kN·mm2'=-0.0572×10.04×2.42=-3.31kN·m8、B8区格板:混凝土泊松比取0.2,l01/l02=4.80/7.20=0.6667,三边固定一边简支,查表得,m1=0.362,m2=0.082,m1'=-0.0789,m2'=-0.0572;周边简支时,查表得,m1=0.0728,m2=0.0279。m1=(0.362+0.2×0.082)×6.203×4.82+(0.0728+0.2×0.0279)×1.50×4.82=7.98kN·mm2=(0.082×0.2+0.362)×6.203×4.82+(0.0279+0.2×0.0728)×1.50×4.82=3.92kN·mm1'=-0.0789×7.703×4.82=-14.71kN·mm2'=-0.0572×7.703×4.82=-10.12kN·m截面设计1、有效高度一类环境类别板的最小混凝土保护层厚度为15mm,假定选用8钢筋,则l01方向跨中截面:h01=100-15-8/2=81mml02方向跨中截面:h02=81-8=73mm支座截面h0=81mm2、配筋计算根据下列公式进行截面设计:,,,配筋表如下:楼面板配筋计算截面板号(mm)(kN·m)(mm2)配筋面积跨中B1l01816.560.07000.9637237.08@200251l02732.250.02950.985090.08@200251B2l01815.270.05620.9711186.18@200251l02731.590.02090.989461.38@200251B3l01812.910.03100.9842101.48@200251l02731.900.02490.987473.18@200251B4l01812.690.02860.985593.58@200251l02731.960.02570.987075.58@200251B5l01812.340.02500.987481.48@200251l02732.340.03070.984490.68@200251B6l01816.190.06600.9659219.78@200251l02733.900.05110.9737152.38@200251B7l01812.630.02800.985891.48@200251l02731.180.01550.992245.48@200251B8l01818.120.08650.9547291.58@150335l02733.670.04820.9753143.28@200251支座B1l0181-11.770.12550.9327424.98@110457l0281-7.850.08360.9563283.38@170296B2l0181-8.350.08900.9533290.28@170296l0281-5.680.06050.9687201.18@200251B3l0181-5.350.05700.9706188.98@200251l0281-4.320.04610.9764151.88@200251B4l0181-4.860.05180.9734171.28@200251l0281-4.210.04490.9770147.98@200251B5l0181-4.790.05110.9738168.78@200251l0281-5.070.05400.9722178.98@200251B6l0181-12.210.13010.9301450.18@100503l0281-9.890.10540.9442359.38@120419B7l0181-4.560.04860.9751160.48@200251l0281-3.310.03530.9820115.58@200251B8l0181-14.000.14920.9188522.48@90559l0281-10.150.10820.9426369.48@1204193、最小配筋率验算配筋率>>=0.2%满足要求。
楼梯设计设计资料采用钢筋混凝土现浇板式楼梯,层高为3.60m,两跑楼梯,梯段高度为180m。每个梯段12级踏步,踏步尺寸为150mm×300mm。采用C30混凝土,受力钢筋采用HRB400,均布活荷载标准值qk=3.50kN/m2。楼梯标准层平面图楼梯标准层梯段图梯段板设计1、板厚确定梯段板的水平投影净长:=3300mm梯段板厚度:=110mm~132mm,取=120mm设计2、荷载计算(对梯段板取1m宽计算)(1)恒荷载磨光花岗岩面层(0.15+0.30)×0.65/0.30=0.975kN/m三角形踏步0.5×0.15×0.30×25/0.30=1.875kN/m混凝土斜板0.12×25×0.8944=2.683kN/m板底抹灰0.02×17×0.8944=0.304kN/m合计:5.837kN/m(2)活荷载3.50kN/m3、荷载组合取γG=1.3,γQ=1.5P=1.3×5.837+1.5×3.50=12.839kN/m4、内力计算跨中最大弯矩可取:5、配筋计算选用钢筋10@200(As=393mm²),分布筋选用8@200。平台板设计1、尺寸取值平台板厚度取100mm,取1m宽板带计算。2、荷载计算(1)恒荷载磨光花岗岩面层0.65kN/m100mm厚混凝土斜板0.10×25=2.50kN/m板底抹灰0.02×17=0.34kN/m合计:3.49kN/m(2)活荷载3.50kN/m3、内力组合取γG=1.3,γQ=1.54、内力计算计算跨度:=1.375+0.1/2+0.2/2=1.525m。弯矩设计值:。5、配筋计算。选配8@200,6、最小配筋率验算,同时大于0.2%,满足要求。平台梁设计1、计算简图平台梁的计算跨度取:l=3600mm,平台梁的截面尺寸为b×h=200mm×400mm。2、荷载计算(1)恒荷载梁自重0.2×(0.4-0.1)×25=1.50kN/m梁侧粉刷0.02×(0.4-0.10)×2×17=0.204kN/m平台板传来3.49×1.75/2=3.05kN/m梯段板传来5.837×3.3/2=9.63kN/m合计:14.38kN/m(2)活荷载kN/m3、荷载组合取γG=1.3,γQ=1.5P=1.3×14.38+1.5×8.84=31.95kN/m4、内力计算计算跨度:l0=1.05ln=1.05×(3.6-0.2)=3.57m<ln+a=3.60m,所以取l0=3.57m最大弯矩:最大剪力:5、配筋计算(1)正截面受弯承载力计算按倒L形截面计算:bf/=1/6lo=1/6×3570=595mm<b+sn/2=200+1500/2=950mm故取受压翼缘计算宽度bf/=595mm平台梁有效高度ho=400-35=365mm=244.73kN·m>42.39kN·m所以属于第一类T形截面。纵向受力钢筋选用316,As=603mm²>329.48mm²(2)斜截面受剪承载能力计算=365mm-100mm=265mm:因为=265/200=1.325<4,截面尺寸按下式验算:=0.25×1×14.30×200×365=260.98kN>=52.01kN截面尺寸满足需求。0.7ftbh0=0.7×1.43×200×365=73.07kN<=52.01kN按构造配箍筋即可。配置φ8@200箍筋,则斜截面受剪承载力=0.7×1.43×200×365+270×50.3/100×365=122.64kN>52.01kN,满足要求。
基础设计基础设计资料(1)钢筋混凝土承台采用C30混凝土,HRB400钢筋,承台下做100厚素混凝土垫层,其混凝土强度等级为C15,每侧比基础承台外边缘各加宽100mm。(2)根据构造要求,在基础下设置100mm厚的C15素混凝土垫层,室内外高差0.45m,基础顶面标高-1.00m,基础埋深1.15m,采用C30混凝土,HRB400级钢筋。(3)地基承载力特征值ƒak=230kPa。(4)基础内力:根据《建筑抗震设计规范》(GB50011-2010)4.2.1规定,不超过8层且高度在25米以下的一般民用框架房屋可不进行基础抗震承载力计算。所以由柱的内力由组合表得到:A柱:荷载效应标准组合值:FK=1585.85kN,MK=227.04kN·m,VK=73.26kN荷载效应基本组合值:F=1953.14kN,M=289.94kN·m,V=92.23kNB柱:荷载效应标准组合值:FK=1777.27kN,MK=268.74kN·m,VK=84.20kN荷载效应基本组合值:F=2569.24kN,M=345.40kN·m,V=107.18kN边柱独立基础设计基础底面尺寸确定假定基础高度h=0.6m,基础埋深为:0.6+0.55=1.15m基础剖面示意图由于基础埋深d=1.15m>0.5m,故需对地基承载力标准进行修正,其承载力修正系数,根据地基承载力特征值公式:假设基础宽度,得到修正后的地基承载力特征值:230+0.3×19×(3-3)+1.6×18.0×(1.15-0.5)=248.72kPa=1.1×1585.85/(248.72-20×1.15)=8.91m初步选定,符合要求。验算持力层地基承载力基础和回填土重为:Gk=γGdA=20×1.15×8.91=204.93kN偏心距为:符合要求。<1.2=1.2×248.72=269.46kpa,故持力层强度满足要求。计算基底反力荷载效应基本组合值:F=1953.14kN,M=289.94kN·m,V=92.23kN静偏心距为:基础边缘处的最大和最小净反力为:柱边基础截面抗冲切验算假设基础高度为:h=600mm,h0=600-50=550mm,基础为锥形基
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 沥青路面白改黑施工方案
- 日海智能:拟质押日海通服服务有限公司股权涉及其股东全部权益价值项目资产评估报告
- 电动门干挂石材施工方案
- 巴中地下室防潮层施工方案
- 宁乡钢筋套筒施工方案
- 2025年安徽省阜阳市阜阳市重点中学中考一模历史试题(原卷版+解析版)
- 【专精特新】激光雷达企业专精特新“小巨人”成长之路(智研咨询)
- 高中语文学术性论著阅读“四维三层”教学设计体系探究
- 中外美术32讲知到课后答案智慧树章节测试答案2025年春西安工业大学
- 三级人力资源管理师-《企业人力资源管理师(理论知识)》考前强化模拟卷8
- 《空气动力学基础》绪论课件
- 卡通插画幼儿园国防教育主题班会课程PPT实施课件
- 红楼梦人物关系图谱可A4打印版
- 第一届全国中学生地球科学竞赛初赛试题试题含答案
- 石化公司建设项目竣工文件整理归档规范
- A4线缆标签数据模板
- 加油站电器火灾应急预案演练记录
- 冲压件,汽车表面零件缺陷及原因分析
- 电熔旁通鞍型
- 2022八年级下册道德与法治全册知识点梳理
- 工程数学线性代数第一章同济第五版ppt课件
评论
0/150
提交评论