美国SOR压力开关

productguide

RegisteredQualitySystemtoISO9001

GeneralApplications

OilGas

EngineeredtoOrderwithOff-the-ShelfSpeedTheexactinstrumentyou

needdeliveredwhenyouneedit.It'swhatSOR?hasbuiltitsreputationon

since1946.SORhasenjoyedthedistinctionofmeetingthechallengesofthe

measurementandcontrolindustryformanyyears.Weprovidethemost

reliableelectronicandelectromechanicalpressure,level,temperatureand

flowinstrumentsavailable.WeListentoOurCustomers

Webuildeachinstrumenttomeetourcustomers'requirementsand

specificneedsfortheOilandGas,PowerGenerationandNuclearindustries.

Thehighestqualityengineeringandconstructionmaterialsandattentionto

thesmallestofdetailsgointoeveryproductwemanufacture-oneatatime.

NeedanApplicationSolution?AskSORNotwoapplicationsareexactly

thesame.Theperformanceanddurabilityofanyinstrumentisinthedetails

andallyouhavetodoistelluswhattheyare.Weworkone-on-onewith

customersallovertheworldtomeettheirindividualapplicationchallenges

andobstacles.WhilethisProductGuideprovidesthespecificationsand

optionsavailableforSORproducts,ourglobalRepresentativesorganization

andfactorySalesengineersalsostandreadytohelpyougettherightdevice

forthejob.Justgiveusacall.

?Wellheadpressure?Flowlinemonitoring?Separatorlevels

?Compressorpressuremonitoring?Sumpcontrol

Petrochemical

?Catalyticcracker?Distillation?Fractionation

?Hydrotreater/Reformer?Coker

?Flareknockouttank?Sumpcontrol

Power

?Fuelstorageandhandling?Steamturbinedriplegs?Hotwellcondenser?

Feedwaterheaters?Demineralization

?Ashprecipitator/scrubber?Steamdrumlevel?Sumpcontrol

ChemicalOther

?Storageandbatchtanklevel?Highlevelalarmsafetyshutdown?

Solventextraction?Rupturediscintegrity?Filterintegrity

?Water/wastewatertreatment?Pulpprocessing

?Rotatingequipmentlubesystems?Sumpcontrol

ContactUs-WeListen913-888-2630800-676-6794913-888-0767Fax

NuclearQualified

Designandspecificationsaresubjecttochangewithoutnotice.

Forthelatestrevisions,visit.

Form901(02.13)?SORInc.

|800-676-6794|913-888-2630

TableofContents

Pressure

Switches

DifferentialSwitches

2467810111212121

3

transmitters

TemperatureSwitches

Level

Switches

transmittersFlow

Switches

EngineeredtoOrderProductsOtherCapabilitiesandServicesNuclear

QualifiedProducts

ClassificationsandAgencyApprovals

Thisbrochureisintendedtoprovidesuggestionsforthe

generalapplicationofcertaintypesofinstruments.Sinceeachapplication

hasuniquecharacteristics,itisrecommendedthat

youconsultSORtodiscussthespecificdetailsofyourapplicationto

ensurethecorrectinstrumentisselected.

913-888-2630|800-676-6794|

Form901(02.13)?SORInc.

1

Weatherproof(Pressure/Vacuum/

compound)

CRN

NN

Weatherproof,TerminalBlockConnections(Pressure/Vacuum/

compound)

CRN

RN

ExplosionProof(Pressure/Vacuum/

compound)

CRN

L

ExplosionProof,UL/CSA/ATEX(Pressure/Vacuum

compound)

CRN

B3

ExplosionProof,

HermeticallySealed

(Pressure/Vacuum/

compound)

CRN

Blg-HERmET

30inHgvacto7000psilbarvacto480bar3YEARWARRANTY?Lowcost

?Setpointadjustmentwithcalibratedscale?pivotsealversion

available

?Formoreinformation,30inHgvacto7000psi

1barvacto480bar3YEARWARRANTY

?Lowcost

?Setpointadjustmentwithcalibratedscale?Formoreinformation,

30inHgvacto7000psi

1barvacto480bar3YEARWARRANTY

?Lowcost

?Setpointadjustmentwithcalibratedscale?Formoreinformation,

30inHgvacto7000psi

1barvacto480bar3YEARWARRANTY

?Terminalblockconnections

?Setpointadjustmentwithcalibratedscale?Setpointadjustment

withoutdeclassificationofhazardousarea

?Formoreinformation,

30inHgvacto7000psi

1barvacto480bar3YEARWARRANTY?Hermeticallysealedsnap

switch(es)

?Setpointadjustmentwithoutdeclassificationofhazardousarea?

Formoreinformation,PRESSURE

SWITCHES

2

Form901(02.13)?SORInc.

Today'sSORPressureSwitchesarethedescendantsoftheoriginalStatic

"O"Ring?mechanicalpressureswitchesthatsetindustrystandardsmorethan

50yearsago.Theyarefield-proven,lowcostprocessinstrumentsforuseas

eitherprimaryorredundantpressureorflowmonitoringapplicationsina

widevarietyofindustries.

|800-676-6794|913-888-2630

Weatherproof(Singlediaphragm)

NN

Weatherproof,TerminalBlockConnections(Singlediaphragm)

CRN

RN

ExplosionProof(Singlediaphragm)

L

ExplosionProof,UL/CSA/ATEX(Singlediaphragm)

CRN

B3

ExplosionProof,

HermeticallySealed(Singlediaphragm)

CRN

Blg-HERmET

CRNCRN

3to500psid0.2to35bar3YEARWARRANTY?Lowcost

?Setpointadjustmentwithcalibratedscale?Formoreinformation,

3to500psid

0.2to35bar3YEARWARRANTY?Terminalblockconnections

?Setpointadjustmentwithcalibratedscale?

Formoreinformation,

3to500psid

0.2to35bar3YEARWARRANTY?Lowcost

?Setpointadjustmentwithcalibratedscale?Formoreinformation,

3to500psid

0.2to35bar3YEARWARRANTY?Terminalblockconnections

?Setpointadjustmentwithcalibratedscale?Setpointadjustment

withoutdeclassification

ofhazardousarea

?

Formoreinformation,

3to500psid3YEARWARRANTY?Hermeticallysealed

snapswitch(es)

?Setpointadjustmentwithoutdeclassificationofhazardousarea

?Formoreinformation,dlffERENTIaL

PRESSURESWITCHES

4

Form901(02.13)?SORInc.

Accuracy,multi-useflexibilityandtheabilitytomatchtheinstrumentto

theapplicationdistinguishSORdifferentialpressureswitchesfrom

off-the-shelfproducts.Standardmodelsareavailableinweatherproofand

explosionproofconfigurationsandcanincludeanexternalsetpoint

adjustmentmechanismforsimplifiedcalibration.

|800-676-6794|913-888-2630

ExplosionProof,HermeticallySealed

(Singlediaphragm)

CRN

mlNI-HERmET

Weatherproof(dual,opposed

piston)

CRN

RB

ExplosionProof(dual,opposed

piston)

CRN

s

ExplosionProof,HermeticallySealed(High-staticoperation)

CRN

102103

ExplosionProof,HermeticallySealed

(Lowrange)

CRN

107

3to500psidOto172bar3YEARWARRANTY?Hermeticallysealed

snapswitch(es)

?Setpointadjustmentwithoutdeclassificationofhazardousarea?

Formoreinformation,0.5to1000psid3YEARWARRANTY?Terminalblock

connections

?Set-pointadjustmentwithcalibratedscale?Formoreinformation,

0.5to1000psid3YEARWARRANTY?Set-pointadjustment

withcalibratedscale?Formoreinformation,7inwcto2500psid

18mbarto175bar3YEARWARRANTY

?Negligibletemperatureand/orstaticinfluence?Hermeticallysealed

snapswitch(es)

?Weatherproofversionavailable

?Setpointadjustmentwithoutdeclassificationofhazardousarea?

Formoreinformation,

0to40inwc

0to1000mmwc3YEARWARRANTY?Setpointadjustmentwith

calibratedscale?Hermeticallysealedsnapswitch(es)

?Weatherproofversionavailable

?Setpointadjustmentwithoutdeclassificationofhazardousarea?

Formoreinformation,913-888-2630|800-676-6794|

Form901(02.13)?SORInc.

5

ExplosionProof805PTWeatherproof,FixedRange503fRlmmersible,Fixed

Range510lm

CRN

100to10,000psi

3YEARWARRANTY

?Compact,hermetically

sealedenclosure

?Stainlesssteelsensor

?0.25%accuracy

?4-20mAor1-5VDC

output

?

Upto5:1turndown?Formoreinformation,

5to2000psi0.34to140barlYEARWARRANTY?Lowcost?

environmentallysealed

electricalconnection

?

Formoreinformation,5to2000psi0.34to140barlYEARWARRANTY?

Suitableforcontinuousliquidimmersion?Compact,stainlesssteel

housing

?

Formoreinformation,PRESSURE

TRaNSmlTTERS6Form901(02.13)?SORInc/Setitandforgetit"reliability

makesSORpressuretransmittersperfectforapplicationswhenspaceistight.

Ourstainlesssteelconstructionstandsuptotherigorsofhostileenvironments

andhazardouslocations.Availablewitheither4-20mAor1-5VDCoutputsand

withadjustablerangesforpressure|

800-676-6794|913-888-2630

Weatherproof

(Directorremotemount)

NN

Weatherproof,ExplosionProof,ExplosionProofExplosionProofTerminal

BlockUL/CSA/ATEXHermeticallySealedHermeticallySealed

Connections(Directorremotemount)(Directorremotemount)(Director

remotemount)(Directorremotemount)

CRN

CRN

CRN

CRN

RN

B3BlgHERmETmlNI-HERmET

CRN

-50°to1000°F-45°to540℃3YEARWARRANTY?Lowcost

?Setpointadjustmentwithcalibratedscale?Formoreinformation,

-50°to1000°F

-45°to540℃3YEARWARRANTY?Terminalblockconnections

?Setpointadjustmentwithcalibratedscale?Formoreinformation,

-50°to1000°F

-45°to540℃3YEARWARRANTY?Terminalblockconnections

?Setpointadjustmentwithcalibratedscale?Setpointadjustment

withoutdeclassificationofhazardousarea?Formoreinformation,-50°to

1000°F

-45°to540℃3YEARWARRANTY?

Hermeticallysealed

snapswitch(es)

?

Setpointadjustment

withcalibratedscale

?Setpointadjustmentwithoutdeclassificationofhazardousarea?

Formoreinformation,

-50°to1000°F

-45°to540℃3YEARWARRANTY?Hermeticallysealedsnapswitch(es)

?Setpointadjustmentwithoutdeclassification

ofhazardousarea

?

Formoreinformation,

Whenyouneedaquickresponse,chooseSOR

temperatureswitches.Theyconsistentlyleadtheindustryinsalesyear

afteryearbecauseoftheirsmalldeadbandrangesandlegendaryreliability.

TEmPERaTURE

SWITCHES

Form901(02.13)?SORInc.

913-888-2630|800-676-6794|7

100SERIES,741-743,801-802

FlangedChamber

CRN

200SERIES,740,803-804

SealedChamber

CRN

700SERIES,730750SERIES

TopMountedDisplacer

CRN

TopMountedFloat

300SERIES

SideMountedFloat

400SERIES

CRNCRN

vacto3500psi

vacto241bar

-65°to1200°F

-54°to649℃5YEARWARRANTY

?Serviceableflangedchamber

?Stainlesssteelswitchingmechanismforharsh

atmospheres

?Formoreinformation,vacto3000psi

vacto207bar-65°to1200°F-54°to649℃5YEARWARRANTY

?Lowcostsealedchamber

?Stainlesssteelswitchingmechanismforharshatmospheres

?Formoreinformation,vacto1000psi

vacto69bar-65°to450°F-54°to232℃5YEARWARRANTY

?Availablein1,2or3-stageswitching?Narrowandwide

differential

?Stainlesssteelswitchingmechanismforharshatmospheres

?Formoreinformation,

vacto750psi

vacto51bar-40°to1000°F-40°to427℃5YEARWARRANTY

vacto1250psivacto95bar-65°to800°F-54°to427℃5YEARWARRANTY

?Availablein1-or2-stage?Horizontalsidemountedswitching

float

?Stainlesssteelswitching?Stainlesssteelswitchingmechanismforharsh

mechanismforharshatmospheres

atmospheres?Formoreinformation,?Formoreinformation,

LEVEL

SWITCHES

8

Form901(02.13)?SORInc.

SORlevelswitcheshaveearnedalong-timereputationfortheirhigh

quality,ruggedconstructionandreliableperformanceunderthemost

demandingapplications.Alllevelswitchesareindividuallybuiltwithstrict

attentiontodetailtomeettheexactspecificationsofyourprocess.

|800-676-6794|913-888-2630

SteamTrapChamberl082081500SERIES,1710CompactLevel701,

711,721722SinglePointUltrasonic

CRNSinglePointRF651681660SERIESMultipoint

RFCRNCRNCRNCRN

vacto5000psivacto345bar

-65°to1200°F-54°to649℃

5YEARWARRANTY?Serviceableflangedorsealedchamber

?Stainlesssteelswitchingmechanismforharshatmospheres

?Formoreinformation,

vacto5000psivacto345bar-40°to400°F

-40°to204℃5YEARWARRANTY?Economicalsideandtopmounted

versionsavailable?Stainlesssteelswitchingmechanismforharsh

atmospheres?Lowcostsealedchamber

available

?Formoreinformation,

0to2000psiOto135bar-40°to250°F-40°to121℃3YEARWARRANTY?

Lowcost?Nocalibrationrequired?Relayandcurrentshift(8/16mA)

outputavailable?316SSsensor?Dualsetpointavailable?Formore

information,

0to4000psiOto275bar-40°to400°F-40°to204℃3YEARWARRANTY

0to4000psiOto275bar-40°to400°F-40°to204℃3YEARWARRANTY?

Lowcost?Uptofourpoints?Singlepointswitchforlevelindicationfor

alarmapplicationspumpcontrol?Relayandcurrentshift?Adjustable

differential(8/16mA)outputfeatureprovidesforavailablepump

control?Avarietyofprobe?Avarietyofprobeconfigurationsmeetmost

configurationsmeetmostapplicationconditionsapplicationconditions?

Formoreinformation,?Formoreinformation,

913-888-2630|800-676-6794|

Form901(02.13)?SORlnc.9

U71,U73,Uli

echOsonix?Non-contactUltrasonicSubmersibleHydrostaticPressure510LE

510Sf670SERIESRF

CRN

18in.(0.45m)

to260化(80m)

2YEARWARRANTY10to463ftwc(3to140m)lYEARWARRANTYUpto

150ft.(45m)3YEARWARRANTY

?continuouslevel

measurementtransmitter

?Measurementrangeup

to150ft.

?Loop-powered,

intrinsicallysafe4-20mA

output

?Avarietyofprobe

configurationsmeet

mostapplication

conditions

?Formoreinformation,

?Powerfultransmitted?NoseconewithNPT(M)pulseforgreater

connectionorflushpenetrationandflexibilitysensordesign?Automatically

adjusted?Unsplicedcablelengthsgaincontinuallyadaptstoupto

3,000ft.processconditions?Rangesfrom10to?Echorecognitionallows

453ftwcautomatedfalse-echo?Compact316SS

handlinghousing?Superiorapplication?

Formoreinformation,flexibility-dust,foam,condensation,angle

ofreposeareautomatically

compensated

?

Formoreinformation,

LEVELTRaNSmITTERSlOForm901(02.13)?SORInc.SORleveltransmitters

continuouslysensetheliquidlevelintanksanddelivera4-20mAcurrent

proportionaltothelevel.Thecurrentoutputcanbeconnectedtoa

programmablelogic

controller,computer,remotedisplayorrelaymoduletodisplay

and/orcontroltheliquidlevelinthetank.Dependingonthe

modelyouchoosemonitoringmaybeaccomplishedwithoutcontacting

theprocess.Ourleveltransmittersmaybeusedasapointorcontinuouslevel

measurement|800-676-6794|913-888-2630

ThermalDifferential

CRNT21900SERIESVaneOperatedl5200EMCRN-100°to392°F

-70°to200℃

Gasesupto500ft/second

Liquidsupto5ft/second

1YEARWARRANTY

?Wideoperatingprocess

temperaturerange

?Designedforliquidand

gasflowapplications

?Removable,plug-in

electronicsboard

?Self-heating

sensordesign

?Formoreinformation,

vacto1480psivacto102bar-65°to800°F-54°to427℃5YEAR

WARRANTY

?Stainlesssteelswitchingmechanismforharshatmospheres?All

ASTMmaterialsconstruction?Flowmonitoringforawiderangeofpipe

sizesandspecificgravities?Formoreinformation,

vacto5000psivacto345bar-40to400°F-40to204℃5YEARWARRANTY?

Allstainlesssteelconstruction?Standardproductratingof1500psi@

(-40°Fto400°F),100bar@-40℃to204℃?Formoreinformation,

SORflowswitcheshaveproventobeworkhorsesintheprocess

instrumentationindustry.Theyareruggedlybuilttoexacting

standardsandprovidelong-lastingservice.fLOW

SWITCHES

Form901(02.13)?SORlnc.913-888-2630|800-676-6794|

ll

ChemicalSeals

SORChemicalSealsarecustom-manufacturedbyReoTempInstruments,

aleadingsupplierofdiaphragmsealswithmanyyearsofexperiencein

specialtyseals.

SORisreadytoworkwithcustomersonanyhigh-performancechemical

sealapplicationsuchashighvacuum,hightemperature,highsterility,custom

design,highstaticpressure/lowdiffer-entialspanorhighvacuum/high

temperature.

Regularorlarge(moresensitive)diaphragm.

Withorwithoutflushingport

THREadEdSEaLS

Regularorlarge(moresensitive)diaphragm.

Forpipesizes:1,1?,2,3,or4”.Withorwithoutflushingport30inHgvac

to2500psi?isolatessensor?All316SS

?Weldedconstruction?Customassembliesmaterialsavailable

fLaNgEdSEaLS

Tri-Clampdesignfor:?,1,1?,2,2?,or3"pipe

SaNITaRySEaLS

30inHgvacto2500psi?isolatessensor?All316SS

?Weldedconstruction?Customassembliesmaterialsavailable

30inHgvacto600psi?Sanitaryisolationofsensor?Quickconnecting

tri-clamp?Meets3Asanitarystandards

Wireless

SORpressure,levelandtemperatureswitchescaneasilybeconvertedto

operateinawirelessmodewiththecustomer'schoiceoftransmitter.

EngineeredtoOrder

NearlyeverySORproductcanbedesignedtomeetthedemandsofyour

processand

custombuilttoyourexactspecifications.Ourmixed-modecapabilities

enableustooperateinajobshopenvironmentwithanOEMmentality.We

specializeinshort-run/quick-turnprojects,butcanalsohandlehigh-volume

work.Allofthisandquickdeliverythatmatchesoff-the-shelfsuppliers.

NuclearQualifiedProducts

SORcustomengineersnuclear-qualifiedpressure,temperature,

differentialandvacuumswitches.Ourengineeringexpertiseisspecifically

targetedtomeettheuniquedemandsofthenuclearpowergeneration

industryandprovidesolutions.Compliant

QualifiedAudited

10CFR50,AppendixBANSIN45.2

NQA-1(includingreporting)

ASMESectionIII,subsectionNCandNDbyacombinationoftestingand

analysisIEEE-323-19741983IEEE-344-19751987

NuclearProcurementIssuesCommittee(NUPIC)NuclearIndustry

AssessmentCommittee(NIAC)

CanadianTechnicalStandardsSafetyAuthority(TSSA)N285.0

12Form901(02.13)?SOR|800-676-6794|

913-888-2630

HazardousAreaClassification

HazardousAreasarelocationswherethepotentialforfireorexplosion

existsbecauseofgases,dustoreasilyignitablefibersorflyingsinthe

atmosphere.

inNorthAmerica,hazardousareasareseparatedbyclasses,divisions,

andgroupstodefinethelevelofsafetyrequiredforequipmentinstalledin

theselocations.Classesdefinethegeneralformoftheflammablematerialsin

theatmosphere.Divisionsdefinetheprobabilityofthep

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论