付费阅读全文
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
专用
人人文库
NATIONALSTANDARD
OFTHEPEOPLESREPUBLICOFCHINA
TechnicalSpecificationforOperationandMaintenance
ofSmallHydropowerStations
GB/T50964-2014
ChiefDevelopmentDepartment:MinistryofWaterResourcesofthePeoplesRepublicofChina
ApprovalDepartment:MinistryofHousingandUrban-RuralDevelopment
ofthePeoplesRepublicofChina
ImplementationDate:October1,2014专用
人人文库
ChinaPlanningPress
Beijing2018
ChineseeditionfirstpublishedinthePeoplesRepublicofChinain2014
EnglisheditionfirstpublishedinthePeoplesRepublicofChinain2018
byChinaPlanningPress
rd
3Floor,CTower,GuohongBuilding专用
No.A11,Muxidi-Beili,XichengDistrict
Beijing,100038
www.jhpress.com
PrintedinChinabyFactoryattachedtoBeijingInstituteofGraphicCommunication
©2014byMinistryofHousingandUrban-RuralDevelopmentof
thePeoplesRepublicofChina
Allrightsreserved.Nopartofthispublicationmaybereproducedortransmittedinanyformor
byanymeans,graphic,electronic,ormechanical,includingphotocopying,recording,
oranyinform人人文库ationstorageandretrievalsystems,withoutwrittenpermissionofthepublisher.
Thisbookissoldsubjecttotheconditionthatitshallnot,bywayoftradeorotherwise,belent,
resold,hiredoutorotherwisecirculatedwithoutthepublisherspriorconsentinanyformof
blindingorcoverotherthanthatinwhichthisispublishedandwithoutasimilarcondition
includingthisconditionbeingimposedonthesubsequentpurchaser.
ISBN978-7-5182-0809-8
中华人民共和国住房和城乡建设部公告
第1128号
住房城乡建设部关于发布小型水力发电站
《
设计规范等两项国家标准英文版的公告
》
现批准小型水力发电站设计规范小型水电站运行维护技术规范
《》GB50071-2014、《》GB/T
两项工程建设国家标准英文版工程建设标准英文版与中文版出现异议时以中文版为
50964-2014。,
准
。
该两项工程建设标准英文版由中国工程建设标准化协会统一组织出版发行
。
中华人民共和国住房和城乡建设部
专用2016年6月6日
人人文库
IntroductiontoEnglishVersion
DepartmentofInternationalCooperation,ScienceandTechnologyofMinistryofWaterResources
(MWR),P.R.Chinahasthemandateofmanagingtheformulationandrevisionofwatertechnology
standardsinChina.
TranslationofthespecificationfromChineseintoEnglishisorganizedbyDepartmentofInternational
Cooperation,ScienceandTechnologyofMWRinaccordancewithdueproceduresandregulationsapplicable
inthecountry.
Technical
ThisEnglishversionofspecificationisidenticaltoitsChineseoriginalGB/T50964-2014
SpecificationforOperationandMaintenanceofSmallHydropowerStations
,whichwasformulatedunderthe
auspicesofMinistryofHousingandUrban-RuralDevelopment(MOHURD),P.R.China.
TranslationofthisspecificationisundertakenbyNationalResearchInstituteforRuralElectrificationof
MWR.
TranslationtaskforceincludesLiZhiwu,RaoDayiandZhangHua.
ThisspecificationisreviewedbySunFeng,ChengXialei,ZhengRugang,QiaoShishan,Meng
Zhimin,WangYicheng,andWuSuhua.专用
DepartmentofInternationalCooperation,ScienceandTechnology
MinistryofWaterResources,P.R.China
人人文库
Foreword
AccordingtotherequirementsofDocumentJianBiao[2008]No.105issuedbyMOHURD-“Noticeon
PrintingtheDevelopmentandRevisionPlan(SecondBatches)ofNationalEngineeringConstruction
TechnicalSpecificationforOperationandMaintenanceofSmall
Standardsin2008”,GB/T50964-2014
HydropowerStations
isformulated.
Thisspecificationcomprises6chapterswiththemainlycontentsasfollows:generalprovisions,basic
stipulations,hydraulicstructures,metalstructures,electro-mechanicalequipment,andoptimizedoperation.
MOHURDisresponsiblefortheadministrationofthisspecification,andMWRfordaily
administration.SpecifictechnicalcontentsinthisspecificationareinterpretedbyBureauofRural
HydropowerandElectrificationDevelopmentofMWR.Ifthereisanyadviceorsuggestioninapplicationof
thisspecification,pleasemailtoBureauofRuralHydropowerandElectrificationDevelopmentofMWR
(No.2,Lane2,BaiguangRoad,XichengDistrict,Beijing100053).
ThisspecificationischieflydraftedbyBureauofRuralHydropowerandElectrificationDevelopmentof
MWR,andNationalResearchInstituteforRuralElectrificationofMWR.
ThisspecificationisjointlydraftedbyGuangshaConstructionGroup专用Co.,Ltd.
ChiefdraftersofthisspecificationareChengXialei,TianZhongxing,LiuZhongmin,LiZhiwu,Xu
Wei,FanXinzhong,LinYanfei,ZhaoJianda,CaiFulin,SunYaqin,GeHandong,ChenYexing,Wang
JianpingandLiChao.
ChiefexaminersofthisspecificationareYangYingdan,SunCongyan,GuoTao,LiJianguo,Yang
Tierong,TangShansong,LuRonghua,QiuJianghai,PanHaijun,SunHongbinandJiangMeiwu.
人人文库
Contents
………………
1GeneralProvisions(1)
………………
2BasicStipulations(2)
………………………
2.1OperationandManagement(2)
…………………
2.2SafetyOperation(3)
………………………
2.3OverhaulandMaintenance(4)
……………
3HydraulicStructures(5)
…………………
3.1RetainingandDischargeStructures(5)
…………………
3.2IntakeStructures(6)
……………
3.3ConveyanceStructures(6)
………………………
3.4PowerhouseandSubstation(7)
…………………
4MetalStructures(9)
………………………
4.1Penstock(9)
………………………
4.2GateandItsLiftingDevice(9)
………………………
4.3Trashrack(10)
………专用…………
5Electro-mechanicalEquipment(11)
…………………………
5.1Turbine(11)
………………………
5.2Generator(14)
…………
5.3SpeedGoverningSystem(19)
………………
5.4ExcitationSystem(20)
…………………
5.5MainValveandOverheadCrane(21)
………………………
5.6Water,OilandAirSystems(23)
……………………
5.7Transformer(25)
……………
5.8SwitchgearInstallation(27)
…………………
5.9RelayProtectionandSupervisionandControlSystem(30)
……………
5.10DirectCurrentSystem(31)
………………
5.11LightningProtectionandGrounding(32)
…………………
5.12Communication(32)
……………
6OptimizedOperation(33)
人人文库………………
6.1GeneralStipulations(33)
………………………
6.2In-plantOptimizedOperation(34)
………
6.3OptimizedOperationforCascadePowerStation(34)
………………
ExplanationofWordinginThisCode(35)
……………
ListofQuotedStandards(36)
1GeneralProvisions
1.0.1
Thisspecificationisformulatedwithaviewtoenhancethemanagementforsmallhydropowerstations
(hereinafterreferredtoaspowerstations),improvethelevelofproductionandmanagementandfinally
achievepowerstationsafetyandoptimizedoperation.
1.0.2
Thisspecificationisapplicabletopowerstationswithatotalinstalledcapacityoforlessthan
50MW.
1.0.3
Provisionsstipulatednotonlyinthisspecificationbutalsointheprevailingnationalstandardsshall
becompliedwithfortheoperationandmaintenanceofpowerstations.
专用
人人文库
·1·
2BasicStipulations
2.1OperationandManagement
2.1.1
On-siteoperationcodeshallbeformulated,revisedandreviewedintimebypowerstationoperationand
managementorganizations,concerningwiththerealsituationofthepowerstationaswellastherequirements
ofthisspecification,inordertoensurethesuitabilityandguidanceoftheoperationcode.
2.1.2
Thepowerstationshallappointoperation,maintenanceandadministrativestaffforstationsafety,as
wellasestablishandimprovetheresponsibilitysystemforeachworkpost.
2.1.3
Administratorsofthepowerstationshallbefamiliarwiththeproductionprocessofthepower
station,andmastertechnicalparameters,operationalrequirementsandsafetyoperationcodesofthe
equipment.
2.1.4
Operationandmaintenancestaffshallreceiveinductiontrainingandgetcertificates.Atleastone
testperyearontheoperationsafetycodeorpracticaloperationshallbeconductedforoperatorsofthepower
station.
2.1.5
Operationandmaintenancestaffshallknowtheproductionproces专用softhepowerstation,masterthe
technicalrequirementsforoperationandmaintenanceaswellascomplywiththesafeoperationcode.
2.1.6
Operationandmaintenancestaffshallstrictlycomplywithworkandoperationsheetsaswellasduty
shifting,inspectiontour,andregularequipmenttestingandrotationsystems,inwhichthequalificationrate
andimplementationrateofworkandoperationsheetsshallbothreach100%.
2.1.7
Ifanyabnormalrunningofthepowerstationsequipmentisfound,operationandmaintenancestaff
shalldecreasetheloadofunitsorstoptheequipmentforinspectionpromptly,thenreporttothedispatching
center.Administratorsshalldulyanalyzethecauses,makereportandorganizerelevantpeopletosolvethe
problems.Anyimportantcasesconnectedwithsafetyshallbereportedtothesuperiorcompetentdepartment
intime.
2.1.8
Asoundfilemanagementsystemshallbesetupinthepowerstation.Alltechnicalmaterials
includingoperation,overhaulanddetectionrecordsaswellastestreportsshallbesortedout,analyzedand
archivedintime.
2.1.9
Theequipmentdefectsmanagementsystemshallbestrictlycompliedwithinthepowerstation.The
eliminationrateforannualequipmentdefectsshallreach100%.
2.1.10
Testingan人人文库dratingoftheequipmentinthepowerstationshallbeconductedaccordingtothe
provisions,andtheintactrateshallreach100%,ofwhichnolessthan80%shallreachClass1intactrate.
2.1.11
Grid-connectedpowerstationsshallcomplywiththedispatchingcodeandrelevantrulesofthe
localgrid,inordertoensurethepowerstationandgridrunsafelyandstably.Thepowerstationshallberun
accordingtotheplanofthegriddispatchingorganizationanditsstipulatedvoltagerange,andthepowerand
voltageadjustedonthebasisofdispatchingorders.Thepowerstationequipmentoverhaulshallcomplywith
unifiedarrangementsmadebythedispatchingorganization.
2.1.12
Anannualreservoircontrolandoperationplanshallbecompiledonthebasisofapproveddesign
floodcontrolstandardandreservoirdispatchingprinciplesofthepowerstation,andthensubmittedfor
approval.Thepowerstationshallalsocomplywithunifiedordersmadebythefloodcontrolorganization.
·2·
2.1.13
Watermanagementcode,hydraulicobservationcode,hydraulicmaintenancecode,hydraulic
machineryoperationandoverhaulcode,hydraulicoperationsafetycodeshallbecompiled,aswellasflood
controlpostresponsibilitysystem,inspectionsystemduring,beforeandafterthefloodseason,hydrological
reportingsystemandannualfloodcontrolsummarysystemformulatedaccordingtotheactualsituationofthe
powerstation.
2.2SafetyOperation
2.2.1
Asafetyproductionmanagementsystemshallbeformulated,andasafetyproductionresponsibility
systemestablishedandcarriedoutinthepowerstation.
2.2.2
Inthehandlingofaccidents,theprincipleofnotoleranceofaccidentswithoutclearidentificationof
causes,thepersonresponsiblefortheaccidentuntreated,unimplementationofrectifiedmeasuresorrelevant
peoplewithoutdrawinganylessonsshallbeadheredto.
2.2.3
Anemergencymechanismshallbesetup,andanemergencyplan,whichshallbesubmittedtothe
relevantdepartmentforapproval,shallbecompiledonaccountofmajorhazardsourcesinthepowerstation
andtherequirementsofcompetentauthorities.Trainingandemergencyresponsedrillsshallbecarriedout
regularly.
2.2.4
On-sitesafetyinspectionsshallbecarriedoutaccordingtotherequirementsofthesafetyinspection
systemofthepowerstation.Anysafetyproblemsdiscoveredshallbereso专用lvedduringtheinspections.Any
unsolvedproblemsshallbereportedtotherelevantresponsiblepersonpromptly,andpreventionandcontrol
measuresshallbeformulated.Inspectionandrectificationshallberecordedandarchived.
2.2.5
SafetyDayactivitiesofthepowerstationshallberegularlyorganizedandwellrecorded.
2.2.6
Safetyproductiontrendsofthepowerstationshallbeanalyzed,accidentlessonsandweaklinkof
productionmanagementsummarizedaswellaspreventivemeasuresformulated.
2.2.7
Trainingonsafetyshallbearrangedasapartoftheannualeducationandtrainingplanofthepower
stationandstrictlyimplementedaccordingtothisplan.
2.2.8
Theequipmentandfacilitiesinthepowerstationshallbenamed,numberedandidentifiedaccordingto
relevantstipulations.
2.2.9
Aworksheetortelephoneverbalordershallberequiredforworkingonhighvoltage(HV)
equipment.OnlytwoormorepeoplecanworkontheHVequipment,andorganizationalandtechnical
measuresforguaranteeingsafetyshallbedonewell.
2.2.10
Forswitchingoperation,switchopeningandclosingwithload,switchclosingwithgroundwire
(earthswitch),groundwirearticulation(earthswitchclosing)withpower,circuitbreakerclosinginerror
andwrongentryto人人文库HVcompartmentsshallbeprevented.Afterelectricalequipmenthastripped,itshallnot
beswitchedonforoperationbeforethecausehasbeenfound.
2.2.11
Powerstationsshallbepreparedforfireandexplosionwork,andequippedwithfireprotection
equipmentaccordingtorelevantstipulations,whichshallbeinspectedandchangedregularlyinorderto
ensuretheyareintactandqualified.
2.2.12
Safetyequipmentandtoolsshallbeequipped,keptandstoredandtestedregularlyaccordingtothe
stipulations.Protectiveclothingandrequisitesforworkersshallbeavailable,inspectedandusedin
accordancewithrelevantstipulations.
2.2.13
Asafetyagreementshallbesignedforthecontractedworksbetweenthepowerstationownerand
thecontractor.Beforethecontractorentersthesite,theoverhaulmanagementfilescompiledbythecontractor
·3·
shallbereviewedandsafetytrainingcarriedoutbythepowerstation.Onlystaffpassingexamsmayenterthe
overhaulsite.Thecontractor’sspecialon-siteoperationworkersshallhavevalidqualificationcertificates,
andtheequipmentandmeterstheyuseshallmeetrelevantsafetyandtechnicalstipulations.
2.2.14
Theoperationalwaterlevelofhydraulicstructures,risingandfallingspeedofthereservoirwater
levelandliveloadshallmeetthedesignrequirements,andbeoperatedandmanagedaccordingtothe
reservoiroperationdispatching.
2.3OverhaulandMaintenance
2.3.1
Overhaulofthepowerstationequipmentshallsatisfytherelevantprovisionsintheprevailing
GuideofMaintenanceManagementforHydropowerStationEquipments
ministerialstandardofDL/T1006.
2.3.2
ThepowerstationequipmentshallbeoverhauledregularlywithanintervalstipulatedinDL/T
1006.Equipmentoverhaulperiodshallbearrangedreasonablyaccordingtofactorssuchasthefeaturesofthe
riverrunoff,andshouldbepreferablycarriedoutinthedryseason.
2.3.3
Anequipmentoverhaulandmaintenancecodeoroverhaulworkguideshallbecompiledforthe
powerstation.Duringtheoverhaul,examinationandacceptanceforqualitycontrolpointsofkeyprocessshall
bedonewell.
2.3.4
Forenterprisesissuingcontractsforoverhaul,anoverhaulcontractshallbemadewiththe
contractor.
2.3.5
Thepreventivetestsaftertheoverhaulforelectricalequipmentsha专用llmeettherelevantprovisionsin
PreventiveTestCodeforElectricPowerEquipment
theprevailingministerialstandardofDL/T596.
2.3.6
Advancedtechnologyandoverhaultoolsshallbeusedfortheoverhaulofthepowerstation
equipmenttoshortentheoverhaulperiod,andoverhaulmanagementshallbeenhanced.
2.3.7
Toolsandlightingfacilitiesusedforpowergeneratingequipmentandemergencyrepairsshallbe
keptandmaintainedbyspecialstaffaswellasinspectedandtestedregularly.
2.3.8
Acceptanceandtrialoperationshallbecarriedoutafteroverhaulandanoverhaulreportshallbe
submitted.
2.3.9
Aninspectionandmaintenancesystemforhydraulicstructuresinthepowerstationshallbesetup.
Thehydraulicstructuresshallbemonitored,inspected,maintainedandrepairedtoeliminatedefectsor
hiddentroubles.
人人文库
·4·
3HydraulicStructures
3.1RetainingandDischargeStructures
3.1.1
Safetyassessmentorsafetytechnicalidentificationforstructuresinthepowerstationshallbecarried
outregularly.
3.1.2
Themonitoringitemsandtimesshallmeetthedesignrequirements.Themonitoringresultsshallbe
analyzedandarchivedintime.
3.1.3
Hydraulicstructuresshallbeinspectedandtouredbystafffrequentlyorregularly.Aninspection
toursystemshallbesetup,inordertodiscoverdefectsandhiddentroublesintime.Theinspectionshall
includethefollowingcontents.
1
Dambodycracks,slopeleakage,bypassseepage,andabnormalleakageorunusualdisplacementof
permeabledamfoundation.
2
Earthdamslopestability;damcrestflatnessandslopeleveling;nocracks,subsidence,bulges,ant
nestsoranimalcaveswithimpactsonstructuralstabilityorseepageflowsafety;completeslopeprotectionof
damsurfacewithnolocaldefectslikelooseness,subsidenceorslumpin专用g,cushionlossorhollowslope
protection;noleakagepools,subsidencearea,piping,abnormalgrowthofplantsandbackflowscouringin
downstreamsurfaceanddamtoe;noturbidseepagewater.
3
Denudation,abrasionorwaterseepageofconcretedambody;nodisplacementbetweenadjacentdam
monoliths;normalperformanceofexpansionjointsandwaterstop;nocracksthataffectthestructureor
seepagesafety;normalchangeofupliftpressure.
4
Intactstructureofdischargestructures;floodwaywithoutanydamage;noabnormalcracks,
settlementsorseepageinthesteepslopes,sidewallsandinnersurfacesoffloodspillwaysandflood
dischargingtunnels;energydissipationfacilitieswithoutanydamage.
5
Intactnessandnormaloperationofancillaryfacilitiesofretaininganddischargestructures.
3.1.4
Maintenanceandrepairofretaininganddischargestructuresshallbeimplementedaccordingtothe
relevantprovisions.Themaintenanceshallmeetthefollowingrequirements.
1
Damcrest,slope,parapetwallandobservationfacilitiesshallbeintact.Drainditchesshallbe
dredgedinordertokeepthemclear.
2
Materialsshallnotbestackedonthedamcrest,slopeorberm.Thedamsurfaceshallnotbeusedas
atransferdock,and人人文库thecrest,slopeanddamtoeshallnotbeusedaswaterconduits.
3
Onthedamandintheupstreamanddownstreamrangesthatmayaffecttheprojectsafety,activities
harmfultotheprojectincludingdiggingpits,buildingfishpondsanddrillingwellsshallallbeforbidden.
4
Erosionandscouringofthedamsurfacebyrainwatershallbeprevented.Thefilteringfacilitiesof
thedambodyandpressurereliefdevicesbehindthedamshallbemaintainedinordertoensurenormal
operation.
5
Inthesilt-ladenareas,reservoirsandflushingfacilitiesshallbeopenedregularly.Forcoldareas,ice
preventionmeasuresshallbeadoptedforbuildings.
6
Onthedamsurface,noplantsandcropsshallbecultivated,nograzingallowed,noturfspaded,and
noremovalofthesandsandgravelsusedforslopeprotectionandseepagediversionfacilities.
·5·
7
Theconcreteweirswithhydraulicautomaticbalancedgatesshallnotonlymeettherelevant
requirementsforconcretedams,butalsoensuretheopeningandclosingflexibilityoftheflapgates.
8
Thedeflatingdevicesofrubberdamsshallbesafeandreliable.Thedambagshallbeintactand
meettherequirementsofflooddischarging.Electromechanicaldevicesandwater(air)fillingpipesshall
workproperly.
9
Thestructureofthedischargestructuresshallbeintact.Ifthereareabnormalcracks,settlementand
waterseepageinthesteepslopes,sidewallsandinnersurfaces,andtheenergydissipationfacilitiesare
destroyed,dischargingshallbestoppedforemergencyrepair.Forthosethatcannotmeettheconditions
temporarily,analternativedischargingschemeshallbeusedinordertopreventworseningtheaccidentand
createconditionsforemergencyrepair.
10
Thesluicewayofthedischargestructuresshallbekeptclear.Duringdischargingperiods,upstream
driftmaterialsshallbesalvagedpromptly,andraftsandshippingshallbestrictlyforbiddentogetclosetothe
entranceofthestructures.
11
Theauxiliaryfacilitiesoftheretaininganddischargestructuresshallbeinnormaloperation.The
dischargingsluicesandvalvesshallbekeptintactwithnormalhoistingandreliableoperatingpower.
12
Ifthereareanydangerousdefectssuchasabnormalcracks,distortionorwaterseepageinthe
retainingstructures,theyshallbedealtwithpromptly.
3.2IntakeStructures专用
3.2.1
Thelowestoperationalwaterlevelofpressureintakesshallmeetthesubmergeddepthrequirements
oftheintake.
3.2.2
Themaintenanceandrepairofintakestructuresshallmeetthefollowingrequirements.
1
Thesideslopeoftheintake(outlet)shallbestable.
2
Theairholeoftheintakeshallbeunobstructed.
3
Thehoistingchambershallbefreeofdebris,anditswindowsanddoorsingoodcondition.
3.3ConveyanceStructures
3.3.1
Inspectionandpatrollingshallberegularlyconductedforconveyancestructures,especiallyforhigh
slopesthateasilycausegeologicalhazards,andshallbestrengthenedduringtherainyseason.Inspectionand
patrollingshallmeetthefollowingrequirements.
1
Thereshallbenocracks,distortion,leakage,erosion,abrasion,cavitation,carbonizationor
lossofwaterstopfi人人文库lling,etc.,intunnels.Themainstructureshallbestable.Thereshallbenoserious
rockfallorwaterseepageinunlinedtunnels,noseriousconcretespallingorwaterseepageinlined
tunnels.
2
Ifinstabilityorwaterseepageoccursinthehillsideofthetunnelintake(outlet),itshallbedealt
withpromptly.
3
Waterfillingordischarginginthetunnelorpenstockshallstrictlycomplywiththeoperation
specifications.Itisnotallowedtopileheavymaterialsortobuildstructuresonthetopoffree-flowculverts,
oronthetopoffree-flowtunnelswithanoverburdenrockthicknesslessthantripleoftunneldiameters.
4
Themainbodyandsideslopeofthechannelshallbestablewithoutsoil-rockcollapseorbank
failure.
·6·
5
Thereshallbenosiltationinsidethechannel.Thereshallbenoabrasion,liningdamageorserious
waterseepageinthechannelsurface.
6
Ifanopenchannelliesbehindthepressureintake,theopeningoftheintakegateshallbestrictly
controlled.Iftheinflowexceedsthedesignvalue,thesurplusflowshallbedischargedthroughthesideweir.
7
Thebodyandpiersoftheaqueductshallbestablewithoutinclination,cracks,damageorserious
waterseepage.
8
Thesurgechambershallbestableasawhole,withnounevensettlement,seepage,cracks,serious
weatheringdenudation,ordamagedlinings.Thestructureofthesurgechambershallbesafeandreliableto
meettherequirementsofflowstabilizationandsurgeincaseofsuddenloadchange.Ventilationinthesurge
shaft(tank)withheadcovershallbekeptsmooth.
9
Thereshallbenodistortion,damagedlining,waterseepageorsideslopecollapseinthebaseplate
ofthepressureforebay,overflowweirandretainingwall.Thefacilitiesofoverflowanddrainageandsand
flushopeningsshallbeintact.
3.3.2
Maintenanceandrepairofconveyancestructuresshallcomplywiththerelevantprovisions.They
shallmeetthefollowingrequirements.
1
Theancillaryfacilitiesofthesurgechambershallbeintactandtight.Thewaterlevelobservation
facilitiesshallbenormalandreliable.
2
Thetunnelshallbeemptiedforinspectionandoverhaulaswellasclearedregularly.
3专用
Theaverageflowvelocityofthechannelunderdesignflowshallbesmallerthanthepermissible
velocityforthefacingmaterials.Thevelocitiesinthechannelshallmeettherequirementsofnodepositionor
noscouringundersediment-ladenconditions.
4
Ifdamage,cracks,erosionorwaterstopageingoccurintheaqueduct,itshallberestoredor
refurbished.Iftherearecracksordistortionintheaqueductbase,itshallberepairedorreinforced.
5
Iftherearebreachesandwaterleakageintheconveyancestructures,whichaffectthemountain
stability,theyshallbedealtwithpromptly.
3.4PowerhouseandSubstation
3.4.1
Thepowerhouseandsubstationshallbeinspectedandpatrolledregularly.Theinspectionshall
complywiththefollowingrequirements.
1
Overallpowerhouseanditsancillaryfacilitiesshallbeintact.
2
Thereshallberegularinspectionstoseewhethertherearecracksandtheirdevelopmentinthe
concretebeams,platesandpillarsofthepowerhouse.Thereshallbenocracksordamageintheconcrete
piersforturbine-gen人人文库erators(T-G).
3
Themountainslopesbehindthepowerhouseandsubstationshallbestablewithoutanycollapse.
4
Thebaseandframeworkofthesubstationshallbestable.
3.4.2
Maintenanceandrepairofthepowerhouseandsubstationshallcomplywiththerelevantprovisions.
Theyshallmeetthefollowingrequirements.
1
Thestrengthanddurabilityofconcretestructuresincludingpowerhouse,substation,operating
bridgeandliftingdevicegirdershallmeetrelevantrequirements.If,thereisseriousdistortion,damage,
cracksorwaterseepagewhichthreatensthesafetyofstaffandequipmentinthecomponentsofthe
powerhouse,andlandsliderisksofthemountaininthepowerhousesite,theyshallbedealtwith
promptly.
·7·
2
Ifthefloodcontrolcriteriaofthepowerhousedonotmeettherequirements,engineeringmeasures
shallbeadoptedintime.
专用
人人文库
·8·
4MetalStructures
4.1Penstock
4.1.1
Thepenstockshallmeetthefollowingrequirements.
1
Anti-corrosivecoatingshallbeevenwithoutsloughing.
2
Thereshallbenoobviousdistortion,cracksorwaterseepageinthepenstock.
3
Itshallbeensuredthatthepenstockcanglidefreelyalongtheaxisofthebuttressslideway.
4
Thereshallbebalancedcompressionandnowaterleakageinthemanholeandleak-proofpackingof
thepenstockexpansionjoint.
5
Forthosepenstocksreachinga40yearsservicelife,safetyinspectionaftertheirdepreciationexpiry
shallbecarriedout.
6
Thebasesandstructuresoftheanchorageblocksandbuttressesforthepenstockshallbeintactand
stablewithoutcracks,damage,obviousdisplacementorsettlement.
4.1.2
Maintenanceofpenstocksshallsatisfythefollowingrequirements.
1
Thesurfaceofthepenstockshallreceiveanti-corrosivetreatmentregularly.
2专用
Ifthereisanycorrosion,crackingorinstability,itshallberepairedorreplacedintime.
3
Ifthegapbetweentheburiedpipeandconcreteaswellasrockwhichjointlybeartheload
increases,groutingofthejointsshallbecarriedout.
4
Dampingmeasuresshallbeadoptediftheexposedpipevibrates.
4.2GateandItsLiftingDevice
4.2.1
Normaloperationofthegateshallmeetthefollowingrequirements.
1
Thereshallbenodistortionorcorrosionwithintactsealingandflexiblepulleysinthegate.
2
Ifcorrosionoccursinthemaincomponentsofthegateincludingfaceplate,girderandedgebeam
andradialgatearms,structuralinspectionshallbecarriedoutintime,andthestrengthandrigidityshallalso
berechecked.
3
Thegateshallbesolidandreliableasawhole.Ifover30%ofthegatecomponentsneedtobe
replaced,thewholegateshallbescrappedandreplaced.
4
Theburiedcomponentsofthegateshallbeinspectedandmaintainedregularly.Thetrackswiththe
seriouserosionorw人人文库ithover2mmofunrepairablejointdislocation,aswellastheotherseriouslycorroded,
rustedorcavitatedburiedcomponents,shallbereplaced.
4.2.2
Normaloperationoftheliftingdeviceshallmeetthefollowingrequirements.
1
Reliablestandbypowershallbeprovidedfortheliftingdevice.
2
Theoperationalelectricaldevicesandancillaryfacilitiesoftheliftingdeviceshallbesafeand
reliable.
3
Protectionmeasuressuchasprotectioncoversshallbeadoptedforoutdoorliftingdevices,andthe
operationalelectricaldevicesshallbelocked.
4
Thereshallnotbetwisting,flattening,bending,cage-likedistortion,brokenstrandsandwaveshape
inthewirecableofthefixedwinchhoist.Thewire,strandandcoreofawirecableshallnotbesqueezedout
·9·
ordamaged.Thewirecableshallbekeptlubricated.
5
Theoperationofthehoistshallbesafeandreliable.
6
Thenoiselevelofthehydraulichoistshallnotbeover85dB(A).
7
Reliableelectricalandmechanicalover-loadsafetyprotectiondevicesshallbeprovidedfor
electricalscrewhoist.
8
Asafetyhandleshallbeinstalledinmanual/electricalormanualscrewhoists.Whenthemanual
deviceofthemanual/electricalhoistisconnectedtothemachine,safetymeasuresshallbeprovidedto
disconnectallcircuits.
4.2.3
Maintenanceofthegateshallsatisfythefollowingrequirements.
1
Aquaticlife,weedsandfilthattachedtothegateandgateslotshallbeclearedtimely.
2
Therotatingcomponentsofthegateshallbekeptlubricated.
3
Fastenersshallbeconnectedreliablywithoutshedding.
4
Duringthefrozenseasonincoldareas,measuresshallbeadoptedtoavoidordecreasetheiceload
onthegate.
5
Aged,worn-out,andrippedwaterstopsshallbereplacedintime.
4.2.4
Maintenanceoftheliftingdeviceshallmeetthefollowingrequirements.
1
Theelectricaldeviceoftheliftingdeviceshallbeintact.
2
Deceleratorandgearsshallberegularlycleared,andhydraulicoilregularlyfilteredandreplaced.
3
Brakingwheelsandbrakescotchsurfacesshallbekeptclean,专用andthebrakeshoegapnormal.
Seriouslywornbrake
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 数据库的开发过程中敏捷方法论应用试题及答案
- 工业互联网平台数据备份与恢复策略在2025年的物联网拓展报告
- 直播行业的社会责任与内容监管实践
- 玻璃可行性分析报告范文
- 广播媒体融合转型2025:新媒体环境下媒体融合的用户需求与行为报告
- 2025年康复医疗器械行业研究报告:市场需求增长创新产品为核心
- 农村一二三产业融合发展的农村水利设施建设与运营报告
- 城市轨道交通智慧运维系统建设与乘客服务体验提升报告
- 快消品包装行业环保创新2025年市场前景报告
- 一星级饭店住宿AI应用行业跨境出海项目商业计划书
- 安全风险四色分布图图例
- 物理才是最好的人生指南
- 来华留学生对中国文化认同感的探究
- 软件系统操作手册模板
- 物流专线合作协议书
- 华兴报告生物育种:前沿生物技术改造下的新农业
- 四川玖谊源粒子科技有限公司回旋加速器生产及同位素应用研发基地环境影响报告表
- 楼顶发光字制作安装合同
- 中德材料中英文对照
- 带电流互感器三相四线有功电表的接线演示文稿
- 市政道路工程重大危险源清单
评论
0/150
提交评论