VascularProtectionTrainingAdvancedClinicalTraining波科介入FilterWire中文保护伞第1页TheProductFeaturesandIntendedBenefits波科介入FilterWire中文保护伞第2页3of128FilterWireEZ™

EmbolicProtectionSystemTheFilterWireEZSystemisBSC’ssecondgenerationembolicprotectionfilter.ItincorporatesanumberofdesignchangesfromtheFilterWireEX™System(FirstGenerationSystem)intendedtoimprovetheeffectivenessandeaseofuse.EuropeSeptembercommercializationforSVG,nativecoronary,peripheralandcarotidinterventionDominantmarketshare(PVandCV)despitemanyotherembolicprotectionfiltercompetitorsUSAugustcommercializationforSVGinterventionIncreasedmarketshareandmarketpenetrationDecember510(k)approvedforcarotidindication波科介入FilterWire中文保护伞第3页4of128FilterWireEZ™

SystemComponentsFilterWireEZ5.5mmSystemProtectionWireEZDeliverySheathEZRetrievalSheathAccessories

(peel-awayintroducer,guidewiretorquer,valvedilatortool)FilterWireEZBentTipRetrievalSheath

(availableseparately)波科介入FilterWire中文保护伞第4页5of128FilterWireEZ™System

AccessoriesPeel-awayIntroducerSheathUsedtopreventdamagetothespringtipoftheprotectionwireduringsysteminsertionintoarotatingorfixedhemostasisvalve.GuideWireTorquerIntendedtoenhancetheoperator’sgripontheprotectionwireforsteerabilityduringdeliveryandtoprovideleverageduringfilterdeploymentandcapture.ValveDilatorToolUsedwithafixedhemostasisvalvetominimizedamagetothefilterbaguponremovalthroughthevalve.波科介入FilterWire中文保护伞第5页6of128FilterWireEZ™SystemPEBAXisaregisteredtrademarkofAtofinaCorporationAtraumatic3cm,platinum,springcoiltipwithfloppyflexibilityRadiopaquetoenhancevisualizationShapeabletoenhancesteerability6.0mmPEBAX®NoseconeFlexibletransitionfromthespringtiptothedeliverysheathforexcellentoveralldeliverabilityProvidesaprofiletransitionthatisdesignedtoreducetheriskofdebrisembolizationduringsystemdelivery波科介入FilterWire中文保护伞第6页7of128FilterWireEZ™SystemPolyurethanefiltermembranewith110micronporesDesignedtocapturesdebrisandreducetheriskofembolicrelatedeventsIntendedtopermitcontinuousbloodflowforpatientsafetyandcomfortIntendedtopermitcontinuousbloodflowthatallowscontrastinjectionsforvisualizationduringtheintervention波科介入FilterWire中文保护伞第7页8of1285.5mm4.5mm3.5mmFilterWireEZ™SystemConforming,nitinolfilterloopwithplatinumcoilHighlyvisibletoguidefilterplacementandtoensuregoodvesselwallappositionOnedevicethataccommodatesvesselswithlandingzonediametersrangingfrom3.5mmto5.5mmminimizessizingguessworkandinventoryneedsDesignedtoprovidecontinuouswallappositionaroundthecircumferenceofthevessellumentominimizetheopportunityfordebristocollectontheoutsideofthefilterAutomaticallyadjuststochangesinthevesselaperture波科介入FilterWire中文保护伞第8页9of128FilterWireEZ™SystemFilterloopsuspensionarmallowsthefilterlooptomoveindependentlyfromthewireforgoodvesselwallappositioninbothstraightandcurvedanatomySimplifiesthelandingzonerequirementsbyallowinguseinbothstraightandcurvedvesselsNoneedtotake2angioviewstoassessfilterapposition波科介入FilterWire中文保护伞第9页10of128FilterWireEZ™SystemSpinnertubeunderlyingfilterassemblyAllowsthewiretorotateindependentlyfromthedeliverysheathforexcellentsystemsteerability.032”ODCatheterstopProvidesabarrierdesignedtopreventtherapeuticdevicesfromcollapsingthefilterframeLightlyvisibletocontributetovisualizationfordevicepositioning**Note:A0.013”ODpart5mmproximaltothecatheterstopmayalsobevisiblewithsomeequipment.Thispartkeepsthespinnertubeinplace,butletscathetertipspassover.波科介入FilterWire中文保护伞第10页11of128FilterWireEZ™System0.014”StainlesssteelwirebodywithPTFEcoatingAvailablein190cmand300cmwirelengths190cmwirelengthiscompatiblewithBSC’sAddWire®GuideWireSiliconecoatedondistal15cmofdevice,delivery,andretrievalsheath.Designedtoreducetheamountofforcerequiredtoloadthefilterintothedeliverysheathanddeployinthevessel波科介入FilterWire中文保护伞第11页12of128EZ

DeliverySheath150cmPEBAX®Resinsheathwith100cm,peel-awayexchangelengthThedistalsheathchangescolorfrombluetocleartoserveasawarningthatthenonpeel-awaysectionattheendofthesheathisapproaching1.1mm(0.042”or3.2F)LesioncrossingprofileDistalendhasaPTFEinnerlinerInternalstoploadingfeature–alertstheoperatorthatthefilterisfullysheathed波科介入FilterWire中文保护伞第12页13of128EZRetrievalSheath150cmPEBAX®Resinsheathwitha20cmlongexchangelengthSoftdistaltipDesignedtofacilitatethecapabilitytocrossdeployedstents1.4mm(0.056”or4.3F)lesioncrossingprofileInternalstopcapturefeatureAlertstheoperatorthatthefilterisfullycaptured波科介入FilterWire中文保护伞第13页14of128EZBentTipRetrievalSheath

(soldseparately)150cmPEBAX®Resinsheathwitha20cmexchangelengthBendatdistaltipThebendisdesignedtoaidincrossingstentstrutsthatcancomplicatefilterretrieval1.3mm(0.052”or4.0F)lesioncrossingprofileInternalstopcapturefeatureAlertstheoperatorthatthefilterisfullycaptured波科介入FilterWire中文保护伞第14页FilterWireEZ™

EmbolicProtectionSystemStep-by-StepInstructionsProductDemonstrationPleaserefertothe

FilterWireEZ™EmbolicProtectionSystemDFUforcompleteinstructionsforuse.波科介入FilterWire中文保护伞第15页FilterWireEZ™EmbolicProtectionSystemDFU

availableat/filterwire

FilterWireEZ™System

DFUCard波科介入FilterWire中文保护伞第16页17of128FilterWireEZ™EmbolicProtectionSystem

Pre-ProcedureReviewthepatient’sangiogramanddetermineifthevesselmeetstherequirementsforsafeandeffectiveuseoftheFilterWireEZSystem:Theapexoftheloopcanbedeployedaminimumof3.0cmfromthedistaledgeofthelesion.

Thevesseldiameteratthedesiredlocationofthedeployedfilterloopis3.5mmto5.5mm.(2.25mmto3.5mmforEZSmall)3.5mm–5.5mmvesseldiameter波科介入FilterWire中文保护伞第17页18of128FilterWireEZ™EmbolicProtectionSystem

Pre-Procedure(continued)PriortousingtheFilterWireEZSystem,anticoagulatethepatienttoachieveanACTof≥275secondsforcarotidapplicationsand300secondsforSVGapplications(>200secondsifGPIIb/IIIainhibitorsareused).IntheabsenceofACTmeasurement,administeranappropriateweightbasedbolusofheparin(approximately125units/kg).波科介入FilterWire中文保护伞第18页19of128FilterWireEZ™EmbolicProtectionSystem

Pre-Procedure(continued)RCAgraft-mostcommonlyusedguideisthemultipurpose.Marginalgraft-HockeystickguideisfirstchoicefollowedbyleftAmplatzLADorDiagonalgraft-mostcommonlyusedguidesaretheleftAmplatzandHockeystick.TakenfromMarcoet.al.“StentingofDegeneratedSaphenousVeinGrafts”MayEuroPCRBasedonvesseltake-off,physicianshouldconsiderwhichguidecathetershapewillprovidethebestaccessandsupport.波科介入FilterWire中文保护伞第19页20of128FilterWireEZ™EmbolicProtectionSystem

PREP:DeliverySystem1.Openthepouchusingsterilehandlingprocedureandplacethepackagingcoilsandaccessorykitintothesterilefield.2.Unclipandremovetheyellowhousingthatprotectsthefilter.

Note:Theprotectionwireispre-loadedintothedeliverysheath.

3.Detachthepre-loaded

protectionwirefromtheretainingclip,advancethedeliverysheath,thengraspthe

clearsectionofthesheath

andremove

sheathedwirefromthecoil.FilterWireEZ™SystemProductPackaging波科介入FilterWire中文保护伞第20页21of1284.SheaththeprotectionwireandfilterbyretractingthedeviceintotheEZDeliverySheathwhilethefilterisimmersedinheparinizedsaline.

NOTE:HoldtheDeliverysheathabout1cmproximaltothedarksection.NOTE:Keepthefilterunsheatheduntilimmediatelypriortouse.FilterWireEZ™EmbolicProtectionSystem

PREP:DeliverySystem(continued)3.Attachthewiretorquerontotheproximalendoftheprotectionwire.GuideWireTorquer波科介入FilterWire中文保护伞第21页22of128FilterWireEZ™EmbolicProtectionSystem

Delivery2.InserttheFilterWireEZSystemandpeel-awayintroducerassemblyintoaguidecatheter/sheath.OncetheFilterWireEZSystemisinsertedintotheguidingcatheterorguidingsheath,removethepeel-awayintroducer.

NOTE:Useofaguidingcatheteroraguidingsheathwitha1.91mm(0.075”)orlargerrotatinghemostasisvalveisrecommendedwhenperformingaprocedurewiththeFilterWireEZSystem.Theuseofasheath/guidecatheterwithafixedhemostasisvalvemaycausethefiltermembranetotearatthehemostasisvalveuponremoval.1.Placethepeel-awayguidewireintroduceroverthetipofthedeliverysystem(thespringtipofthesystemcanbeshapedasneeded).Peel-awayIntroducerSheath波科介入FilterWire中文保护伞第22页23of128FilterWireEZ™EmbolicProtectionSystem

Delivery(continued)3.ToadvancetheFilterWireEZSystemthroughtheguidingcatheterorguidingsheath,useaone-handedtechniqueadvancingboththedeliverysheathandprotectionwiretogether;thiswillpreventaccidentaldeploymentofthefilter.4.TosteertheFilterWireEZSystemtothetargetlandingzone,useatwo-handedtechnique,torquingtheprotectionwirewithonehandandadvancingthedeliverysheathwiththeotherhand.NOTE:Forcarotidinterventions,havingthepatientturntheirheadtotheleftorrightwillchangetheorientationofthevesselandmayfacilitatedevicepassage.

NOTE:Considerusingthebuddywiretechniqueifthelesionisdifficulttopass.RetractthebuddywireafterthelesionhasbeencrossedbytheFilterWireEZSystem(Ifothereffortsareunsuccessful,pre-dilatationcanbeused.)波科介入FilterWire中文保护伞第23页24of128FilterWireEZ™EmbolicProtectionSystem

Delivery(continued)5. AdvancetheFilterWireEZSystemacrossthelesionuntiltheapexofthefilterloopcanbedeployedaminimumof3.0cmdistaltothelesion.NOTE:Ifaninterventionaldevicewithatip-to-shoulderlengthofgreaterthan10.0mmistobeused,alongervessellengthmayberequiredtoplacetheFilterWireEZSysteminordertoavoidcontactbetweenthefilter’scatheterstopandthetipoftheinterventionaldevice.波科介入FilterWire中文保护伞第24页25of128Oncetheprotectionwireisinplacepastthelesion,slidethetorquertipuptothehemostaticvalveandtightenfirmly.Deploythefilterbyholdingtheprotectionwirewiththetorquer,thenretractingandcompletelyremovingthedeliverysheath.Besuretokeepthetorquerinplaceasyoupeel-awaythedeliverysheathinastraightmotionuntilthe3cmover-the-wiresectionisreached(seephotobelow).FilterWireEZ™EmbolicProtectionSystem

FilterDeploymentincorrectCORRECTPhotographtakenbyBostonScientificCorporation波科介入FilterWire中文保护伞第25页26of1284. Oncethedeliverysheathiscompletelyremoved,injectcontrastandverifythedeviceisintheproperpositionandthereisadequateflow.

NOTE:Ifrepositioningisrequired,theEZRetrievalSheathshouldbeused.Retracttheprotectionwireandfilterloopintothesheath,repositionthefilterandredeploy.5. Usetheprotectionwirelikeatraditionalguidewiretotrackcathetersandstentdeliverysystemstothetargettreatmentarea.FilterWireEZ™EmbolicProtectionSystem

FilterDeployment(continued)波科介入FilterWire中文保护伞第26页27of1281.Injectcontrastfrequentlyandalwaysafteranyinterventionorexchange,tovisuallyverifythatbloodflowisnotobstructedandthatfilterloop/vesselappositiontothevesselwallismaintained.

CAUTION:Ifafilterbecomesoccludedduringtheprocedure,removeitanddeployasecondfilteriffurtherinterventionisrequired.2.Completetheproceduremakingsuretheprotectionwireremainsintheproperpositiondistaltothelesion(monitorfluoroscopy).

Note:Failuretostabilizetheprotectionwirecouldleadtoinadvertentmovementofthefilter,resultinginprotectionwireentanglementand/ordelayintheprocedure.FilterWireEZ™EmbolicProtectionSystem

DuringtheProcedure波科介入FilterWire中文保护伞第27页28of128FilterWireEZ™EmbolicProtectionSystem

FilterCaptureandRetrieval1.RemovetheEZRetrievalSheathfromitspackagingcoilandflushwithheparinizedsaline.2.Advancetheretrievalsheathovertheprotectionwirepastanydeployedstentsuptotheproximalendofthefilterloop.Note:IftheEZRetrievalSheathisnotabletopassthedeployedstent,besurethestentiswellapposedandconsiderpost-dilitation.IftheRetrievalSheathisstillunabletocross,trytheEZBentTipRetrievalSheath(availableseparately).EZBentTipRetrievalSheathPackaging波科介入FilterWire中文保护伞第28页29of128FilterWireEZ™EmbolicProtectionSystem

FilterCaptureandRetrieval(continued)3.Gentlyandslowlyretracttheprotectionwireandfilterloopbackintotheretrievalsheathuntilresistanceisfelt.4.Observetheretrievalprocedureunderfluoroscopicimaging.Note:Thedistaledgeofthecollapsedfilterloopshouldalignwith(seefigureB),orbeproximalto(figureA),theretrievalsheathmarkerband.

RetrievalSheathMarkerBandAB波科介入FilterWire中文保护伞第29页30of128FilterWireEZ™EmbolicProtectionSystem

FilterCaptureandRetrieval(continued)

NOTE:Ifresistanceisfeltbeforethedistaledgeofthecollapsedfilterloopisalignedwiththemarkerband,itispossiblethatthereisalargeamountofembolicdebrisinthefilter.CarefullyretracttheprotectionwireandEZRetrievalSheathasasystem.Thedistalpartofthefilterbagwillbeoutsideofthesheathduringretrievalinthiscase;however,thefilterloopmustbepulledfullyintothesheath.FullyRetractedFilterLargeDebrisLoadinFilter波科介入FilterWire中文保护伞第30页31of128FilterWireEZ™EmbolicProtectionSystem

FilterCaptureandRetrieval(continued)5.IfanyresistanceismetduringretractionofthesheathedFilterWireEZSystem,slightlyadvancethesheathedFilterWireEZSystemandrotatethesheathbeforecontinuingtoretract.6.Slowlyandcarefullyretracttheentiresystemuntilthetipoftheretrievalsheathisadjacenttothetipoftheguidingcatheterorguidingsheath.7. Ifthereisanyresistance,retracttheguidingcatheterandFilterWireEZSystemtogether.Thisisdoneincasethereisalargeamountofembolicmaterialcapturedinthefilterthatmaynotfitinsidetheguidingcatheter.波科介入FilterWire中文保护伞第31页32of128FilterWireEZ™EmbolicProtectionSystem

FilterCaptureandRetrieval(continued)8.RemovetheFilterWireEZSystemfromthepatient. NOTE:Whenusinga

rotatinghemostasisvalve,ensurethatthehemostasisvalveisfullyopenedpriortoFilterWireEZSystemremoval.

CAUTION:Ifaguidesheathwithafixedhemostasisvalveisused,thevalvedilatortoolisrequiredforFilterWireEZSystemremoval.RemovingtheFilterWireEZSystemthroughafixedhemostasisvalvewithouttheuseofavalvedilatormaycausethefiltermembranetotear.9.Ifafixedhemostasisvalveisused,placethevalvedilator(ifprovidedintheaccessorykit)ontheshaftoftheretrievalsheathandslidethetoolintothevalve.ThenremovetheFilterWireEZSystemfromthepatientthroughthevalvedilatortoolandremovethedilator.波科介入FilterWire中文保护伞第32页33of128StentEntanglementPotentialforadistalembolicprotectionfiltertoentanglewithastentisinherenttointerventionalproceduresusingthesedevices.SAFEPRACTICEFORDISTALPROTECTIONFILTERS:AchievegoodguidecatheterorguidesheathsupportEnsuresufficientlandingzoneKeepthefilterinplaceduringdeploymentMinimizewiremovementduringtheprocedureAchievefullstentapposition波科介入FilterWire中文保护伞第33页34of128FilterWireEZ™EmbolicProtectionSystem

TipsforUseKeySuccessFactorsforUsingtheFilterWireEZSystemKeepACTlevels275secondsforcarotidproceduresand300secondsforSVGprocedures.Ifthereisdifficultycrossingthelesion,tryabuddywireand/or,forcarotidprocedures,havethepatientturntheirheadtotheleftorright.Forcarotidprocedures,placethefilterasdistalaspossiblewhileremainingwithintheextracranialportionoftheICA.Duringdeploymentandexchanges,stabilizethewireandwipeitfrequentlytodecreasefriction.Keepyoureyeonthefilter!Knowwhereitisandknowwhereitissupposedtobe.Verifyflowoften.Slowflow?Finishtheprocedureandremove.Noflow?Removeandreplace.TheFilterWireEZSystemneedsflowtofunction.Donottreatthelesionor“touchup”withoutaFilterWireEZSysteminplace.波科介入FilterWire中文保护伞第34页CompetitionRXACCUNET®(Abbott)Angioguard(Cordis)Emboshield®System(Abbott)Spider(ev3)波科介入FilterWire中文保护伞第35页36of128Competition

FixedWireFilters‘SheathedFixedWire’Devices:FilterWireEZ™System,RXAccunet®,Characteristics

Filterattachedtoa proprietarywireDeliverysheathrequiredPhotobyBostonScientific波科介入FilterWire中文保护伞第36页37of128Competition

WireofChoiceFilters‘WireofChoice’Device:SpiderFX®Device, EmboshieldCharacteristics:Useany.014”wiretogainaccessDeliversheathedfilterandproprietaryguidewireoverthe‘wireofchoice’,thenremove‘wireofchoice’Wirecanmoveslightly(~8mmoflongitudinal“play”)withoutmovingfilterCANNOTremove/replacedeployedfilterwhilemaintainingaccessSpideRX®波科介入FilterWire中文保护伞第37页38of128Competition

OcclusiveDevicesDistalOcclusionDevice:MedtronicGuardWire®SystemCharacteristics:ProprietarywirewithballoonattachedLowcrossingprofileBallooninflateddistaltolesionShortlandingzoneAspiratetoremoveemboliProximalOcclusionDevices:St.JudeProxis®System

CharacteristicsOcclusiveprotectionpriortocrossinglesionProxisstopsflowandthenaspiratestoremoveemboliProxis®GuardWire®波科介入FilterWire中文保护伞第38页ImagebyBostonScientificCorp.AbbottVascularDevicesRXACCUNET®EmbolicProtectionSystem波科介入FilterWire中文保护伞第39页40of128Competition

RXACCUNET®SystemDeliveryRetrievalFilterBagDeliverymethod:SheathedwireImagesbyBostonScientificCorp.波科介入FilterWire中文保护伞第40页Competition

RXACCUNET®SystemFilterSizeFullyExpandedReferenceVesselDiameter(MintoMaxRange)MinimumSheathSizeMINIMUMGUIDINGCATHETERSIZE4.5mm3.25mm–4.0mm6F8F5.5mm4.0mm–5.0mm6F8F6.5mm5.0mm–6.0mm6F8F7.5mm6.0mm–7.0mm6F8FTechnicalspecsexcerptedfromRXACCUNETSystemDirectionsforUseandotherliteraturepublishedbyAbbottVascularatasofMarch10,波科介入FilterWire中文保护伞第41页42of128Competition

RXACCUNET®SystemFilterWireEZSystemRXACCUNETSystemDeliveryMethodSheathedwireSheathedwireCrossingProfile3.2F3.5&3.7FDistalTip3.0cm3.0cmVesselDiameterCoverage3.5mm–5.5mm3.25mm–7.0mm(4sizes–4.5,5.5,6.5,7.5)PoreSize110micronRangesupto150micronDeviceWireCharacteristicsModeratesupportExtrasupportLandingZone>3.0cm>4.0cmAppositionCheck1view2viewsRetrievalSheathProfile4.3F5.5FWireLengths190cm,300cm190cm,300cmGuideCatheterReq.6F(minID0.066”)8F(minID0.085”)IndicationsCarotid,SVGCarotidInformationexcerptedfromFilterWireEZSystemandRXACCUNETSystemDirectionsforUseandotherliteraturepublishedbyAbbottVascularatasofMarch10,波科介入FilterWire中文保护伞第42页43of128ExcellentDeliverabilityGuidewireanddeliverysheathentervesselasoneunitHighlyflexibletonavigatetortuousanatomyLowprofileandsmoothtransitionfromtiptofilterbasket.014”wireistorquedindependentfromfilterbasketAccurateDeploymentRapidexchangeunsheathingforstabilityandsimplicityPeelawaydeliverysheathallowsforcontrolleddeploymentCaptureandControlforOptimalProtectionHighlyflexiblefilterbasketdesignedtoconformtotortuosityDesignedtocapturehighvolumewhileallowingadequatebloodflowConcentricdesignwithguidewirecenteredinfilterFourplatinumradiopaquemarkerssurroundfilterforvisualizationofwallappositionSecureFilterRetrievalChoiceoftworapidexchangerecoverycathetersdesignedspecificallyforthechallengesoffilterrecovery.RXACCUNETRecoveryCatheterShapeabledistaltipsteerscatheterfromstentstrutsduringadvancementFilterbasketsecuredwithallcagestrutopeningsenclosedduringwithdrawalRXACCUNET2RecoveryCatheterLow-profile,flexibletiptoallowfordeflectionawayfromstentstrutsduringadvancementFlexiblecatheter/shaftoptimizedforchallengingguidecatheter/sheathaccessCathetershaftmarkersat95and105cmforreducedflourotimeCompetition

RXACCUNET®SystemInformationononRXACCUNETSystemexcerptedfromliteraturepublishedbyAbbottVascularat.波科介入FilterWire中文保护伞第43页44of128ACCUrateCaptureandControlTheRXACCUNETSystemisdesignedtoprovideexcellentcapturecapabilitiesandeasyfiltercontrolwhenperformingcarotidstentinginterventions.TheRXACCUNETSystemisa.014”guidewirebasedfiltersystemthatutilizesrapidexchangetechnologysothatthephysiciancaneasilycontrolthefilterduringcathetermanipulations.Itisavailableinboth190cmand300cmlengthswiththeproximalendofthe190cmdevicecoinedtoallowforattachmenttoa“DOC”wireextension.Thesystemis6Fsheath/8Fguidecathetercompatibleandhasfiltersavailablein4.5,5.5,6.5,and7.5mmbasketdiametersthatarerecommendedforuseinarteriesrangingfrom3.25mmto7.0mm.TheRXACCUNETSystem’sflexiblecagedesignassistsinmaintainingexcellentwallappositioninpulsedflowenvironmentsandchallenginganatomies.TheRXACCUNETSystem’speelawaydeliverysheathallowsforsimpledeploymentwithrapidexchangeunsheathingforstabilityandeaseofuse.Additionally,the.014”wirecanbetorquedindependentlyfromthefilterbasketinordertohelpmanagethenavigationoftortuousanatomy.RecoveryisperformedwithachoiceoftwodedicatedRXrecoverycatheters.

TheoriginalRXACCUNETRecoveryCatheterhasashapeabledistaltipdesignedtooffersteeringcontrolduringadvancement.TheRXACCUNET2RecoveryCatheterislowerprofileandmoreflexibleandwasdesignedtoaccessmoretortuousanatomieswithoutcatchingonstentstruts.Competition

RXACCUNET®System

-PositioningInformationonRXACCUNETSystemexcerptedfromliteraturepublishedbyAbbottVascularandmadeavailableatasofMarch10,波科介入FilterWire中文保护伞第44页ImagebyBostonScientificCorp.AbbottVascularDevicesEmboshield®BareWire®RapidExchangeEmbolicProtectionSystem波科介入FilterWire中文保护伞第45页46of128Competition

Emboshield®SystemDeliverymethod:BareWire®Device/wirefirstCrosslesionwithprovided

BareWireDevice,thenadvanceFilterDeliveryCatheteroverBareWireDevicetodeploymentsite(note:thefiltercanonlybepositionedproximaltothe0.019”stepontheBareWireDevice)DeliveryRetrievalFilterBagImagesbyBostonScientificCorp.InformationexcerptedfromEmboshieldSystemDFU.波科介入FilterWire中文保护伞第46页Competition

Emboshield®SystemFilterDiameterVesselSizeRangeCrossingProfile3.0mm2.8-<3.5mm3.7F4.0mm3.5-<4.2mm3.7F5.0mm4.2-<5.2mm3.9F6.0mm5.2–6.2mm3.9FSupportLevelLength(cm)Soft190,315Medium190,315Extra190,315Super190,315Maximum190,315Emboshield®SystemBareWireTechnicalspecsexcerptedfromEmboshieldSystemDirectionsforUseandotherliteraturepublishedbyAbbottVascularandmadeavailableatasofMarch10,波科介入FilterWire中文保护伞第47页48of128Competition

Emboshield®SystemFilterWireEZSystemEmboshieldSystemDeliveryMethodSheathedfilterwireBareWire®Device/wirefirstCrossingProfile3.2F3.7&3.9FDistalTip3.0cm3.0cmVesselDiameterCoverage3.5mm–5.5mm2.8–6.2mm(4sizes–3,4,5,6)PoreSize110micron140micronDeviceWireCharacteristicsModeratesupport5supportlevels(soft,medium,extra,super,maximum)LandingZone>3.0cm>3.6–4.3cmAppositionCheck1view2viewsRetrievalSheathProfile4.3F5.4FWireLengths190cm,300cm190cm,315cmGuideCatheterReq.6F(minID0.066”)7FIndicationsCarotid,SVGCarotidInformationexcerptedfromFilterWireEZSystemandEmboshieldSystemDirectionsforUseandotherliteraturepublishedbyAbbottVascularandavailableatAsofMarch10,.波科介入FilterWire中文保护伞第48页49of128Competition

Emboshield®SystemPerceivedStrengthsPerceivedWeaknessesAbilitytocrosstightlesionsusingarelativelysimplesystem(providedguidewirewith0.019”stop)Lowcaptureefficiencyonabend1Abilitytoretrievethefilterwhileleavingthewireinplace.Significantforceisrequiredtodeliverthedevice2Multiplesizeswithvesselcoverageof2.8to6.2mmdiameterLimitedradiopacityRequirescrossingthelesiontwicepriortoprotection–firstwithBareWireandthenw/deliverycatheterIncreasedproceduraltimeLargelandingzonerequiredImagesbyBostonScientificCorp.波科介入FilterWire中文保护伞第49页50of128InformationonEmboshieldSystemexcerptedfromliteraturepublishedbyAbbottVascularandmadeavailableatasofMarch10,Competition

Emboshield®System-PositioningDesignedforChoice,Safety,ConfidenceWiththeBareWire®Device,thewirecrossesthelesionfirst,independentofthefilteranddeliverycatheter.Allotheractions,includingfilterplacementandretrieval,balloondilatations,andstentplacementthenoccuroverthewire.

CHOICEFiveDifferentWireSupportLevelsEachavailableintwolengthsofferlesion-specificaccessandsupportTheSupersupportBareWireDeviceispackagedwiththe EmboshieldSystemSAFETYOptimizedFitofRetrievalCathetertoWireSnugfitofcathetertiptowireenhancestrackabilityand reducesthelikelihoodofcatchingonthestent.CompleteFilterEncapsulationforthesecureremovalofdebrisEmboshield

SystemenablescompleteretrievalforthesecureremovalofdebrisCONFIDENCESupportLevelSoftMediumExtraSuperMaximum波科介入FilterWire中文保护伞第50页SpiderFXDevicepictureexcerptedfromliteraturepublishedbyeV3andmadeavailableatasofMarch10,ev3Spi

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论