FETINDUSTRIALWATEWATEROPERATORTRAININGMETALFINISHING/METALMOLDINGANDCASTINGSESSION1–OCTOBER4,2006RobertPeschel,P.E.(414)643-4150(Sigma)rpeschel@FETINDUSTRIALWATEWATEROPERA1SESSION1IntroductionofCourse/ParticipantsCourseOutlineText:TreatmentofMetalWastestreamsNeedforTreatment(Chapter1)RegulatoryOverviewOpportunitiesSourcesofWastewater(Chapter2)MaterialSafetyDataSheets[MSDS](Chapter3)EmployeeRight-To-Know(Chapter4)ArithmeticProblems(AppendixIII)MethodsofTreatment(Chapter5)BatchandContinuousProcesses(5.0)Neutralization(5.1)CommonMetalsRemoval(5.2)ComplexMetalsRemoval(5.3)ReductionHexChrome(5.4)CyanideDestruction(5.5)SESSION1IntroductionofCours2COURSEOUTLINEOCTOBER4 Introduction/Overview Robert

Peschel RegulatoryOverview BasicMath BasicsofTreatment HexavalentChromeReduction CyanideDestructionMetalsRemoval ExampleCalculations/ProblemsOCTOBER11OilyWasteRemoval ScottHartayControlofSolvents/ToxicOrganicsSludgeTreatment&Disposal

SamplingFlowMeasurements SteveGalewski LaboratorySupport ExampleCalculations/ProblemsOCTOBER18 Operation&Maintenance TBD Equipment&Instrumentation ExampleCalculations/Problems RecoveryTechnologies KennethKaszubowskiOCTOBER25 TourofPretreatmentSystem CourseReview RickFulkCOURSEOUTLINEOCTOBER43NEEDFORTREATMENTREGULATORYOVERVIEWCleanWaterActObjectiveandGoalsPoliciesStructureImportantSectionsNPDESPretreatmentStormwaterNEEDFORTREATMENTREGULATORYO4OBJECTIVEOFCWATorestoreandmaintainthechemical,physical,andbiologicalintegrityofthenation’swaters GOALSOFCWAAchievefishableandswimmablewaterby1983(interim)Eliminatethedischargeofpollutantsintonavigablewatersby1985OBJECTIVEOFCWATorestoreand5NATIONALPOLICIESOFCWAProhibitdischargeoftoxicsintoxicamountsProvidefederalassistancetoconstructPOTWsDevelopandimplementarea-widewastetreatmentmanagementplantsineachstate(208plans)ConductR&DnecessarytodevelopzerodischargetechnologyDevelopprogramstocontrolnon-pointsourcesofpollutionEncouragetheminimizationofpaperworkandinteragencydecisionsNATIONALPOLICIESOFCWAProhib6STRUCTUREOFACTTitle1ResearchandRelatedProgramsTitle2GrantsforPOTWConstructionTitle3StandardsandEnforcementTitle4PermitsandLicensesTitle5GeneralProvisionsTitle6StateRevolvingFundsSTRUCTUREOFACTTitle1Resea7TITLE1

RESEARCHANDRELATEDPROGRAMSObjective,goals,andpoliciesCoordinationbetweenstateandfederalagenciesDevelopresearchprojectsDevelopdemonstrationprojectsDevelopoperatortrainingprogramsDevelopspecificprograms(GLNPO)TITLE1

RESEARCHANDRELATEDP8TITLE2

CONSTRUCTIONGRANTSFederalgrantprogramAuthorizesfundingDefineseligibleprojectsSetsparticipationrequirementsEstablishesplanningprograms(208)EstablishesallotmentformulaTITLE2

CONSTRUCTIONGRANTSFed9TITLE3

STANDARDSANDENFORCEMENTStandardsandstandardsettingproceduresPollutants(priority)DeadlinesVariances&waiversWaterqualitycriteriaInventoriesofwaterqualityMonitoring&recordkeepingEnforcementprogramsSpillsofhazardoussubstancesTITLE3

STANDARDSANDENFORCEM10TITLE4

PERMITSANDLICENSESNPDESpermitsystemDischargercertification/publiccommentDelegationtostatesAnti-backslidingStormwaterdischargesOceandischargesDredge&filloperationsSludgedisposal/managementTITLE4

PERMITSANDLICENSESNP11TITLE5

GENERALPROVISISONSGrantsauthoritytoEPAtocarryoutlawProvideskeydefinitionsCreatesadvisoryboardsCitizenssuitprovisionEmployeeprotectionforreportingviolationsSupplyofgoods&servicestofederalgovernmentPeriodicneedssurveysAmericanIndiantribestreatedlikestatesStateauthorityforNPDES/PretreatmentProgramsTITLE5

GENERALPROVISISONSGra12EFFLUENTLIMITATIONSSourcecategorybasisIndustrialcategoriesTechnologybasedlimitsConventionalandtoxicpollutantsLocallimitsEFFLUENTLIMITATIONSSourcecat13EFFLUENTLIMITATIONSDirectdischarges–NPDESIndirectdischarges–toPOTWExistingsources(3years)Newsources(90days)BPT,BCT,BAT,BADCTConcentrationvs.massEFFLUENTLIMITATIONSDirectdis14STANDARDSBPT-BestPracticableControlTechnology.Currentlyavailable.Subjecttocost-benefitanalysis.(middlegroundbetweenBCTandBAT)BCT-

BestConventionalControlTechnologySubjecttocosteffectivenessstandard.Mustbemetwithinthreeyearsofeffectiveguidelinesor3/89.BAT-

BestAvailableTechnologyEconomicallyAchievable.Deemedachievableunlessplantclosurewouldresult.Mustbeinstalledwithinthreeyearsofguidelineor3/89.BADCT-fornewsources(NSPS).BestAvailableDemonstrableControlTechnologyNSPS-

NewSourcePerformanceStandardsPSNS-

PretreatmentStandardsforNewSourcesPSES-PretreatmentStandardsforExistingSourcesSTANDARDSBPT-BestPracticable15POLLUTANTSConventionalBOD,TSS,pHNon-conventionalAmmoniaToxicsPrioritypollutants(65)MetalsOrganicspesticidesPOLLUTANTSConventional16NPDESPERMITSRequiredforanydischargeof“Pollutant”fromany“PointSource”intoany“WatersoftheU.S.”KeytoenforcingCWAlimitsandstandardsDelegationtoStates(e.g.WPDES)AllowsforpublicinvolvementinpermittingprocessCanbemodifiedforreasonAnti-backslidingprovisionsNPDESPERMITSRequiredforany17PRETREATMENTREGULATIONSOBJECTIVESPreventpass-throughoftoxicstoreceivingwaterPreventinterferencewithPOTWoperationsPreventcontaminationofsludgesProtecthealthandsafetyofworkersPRETREATMENTREGULATIONSOBJEC18PRETREATMENTPROGRAMFRAMEWORKEPAhasprimeresponsibilityDelegationstostateswithapprovedprogramsPOTWs>5MGDmustestablishformalprogramandhavefirsttimeresponsibilityMMSDChapter11POTWs<MGDhavestateorEPAinvolvementPRETREATMENTPROGRAMFRAMEWORK19PRETREATMENTSTANDARDSGeneralprohibitivestandardsFireorexplosionhazardCorrosive,pH<5FlowobstructionSlugloadsHeatToxicgassesorvaporsCategoricalstandardsLocalPOTWlimitsCombinedwastestreamformula[409CFR403.6(e)]Moststringentstandardapplies!PRETREATMENTSTANDARDSGeneral20PRETREATMENTSTANDARDSGeneralprohibitivestandardsFireorexplosionhazardCorrosive,pH<5FlowobstructionSlugloadsHeatToxicgassesorvaporsCategoricalstandardsLocalPOTWlimitsCombinedwastestreamformula[409CFR403.6(e)]Moststringentstandardapplies!PRETREATMENTSTANDARDSGeneral21MAJORINDUSTRIALWASTEPROGRAM(IWP)COMPONENTSSeweruseordinancePermittingproceduresCompliancemonitoringEnforcementFundingmechanismBiennialreviewofeffluentlimitationsMAJORINDUSTRIALWASTEPROGRAM22STORMWATERREGULATIONSMostpointsourcesarenotundercontrolthroughNPDESpermitsWaterwayinheavilypopulatedareasarestillbeingdegradedMoststateshaveidentifiedstormwaterasleadingcauseofimpairmentVariousstudieshaveconfirmedproblemsIllicitConnectionstillexistIllegaldumpingstilloccursCongressionalmandatesSTORMWATERREGULATIONSMostpo23WHAT’SINAPERMITEffective/expirationdatesMonitoringandreportingrequirementLocationFrequencyParameterlimitsParametermonitoringNotificationReportingEnforcementSignatoryrequirementsWHAT’SINAPERMITEffective/ex24MMSDChapter11

ProhibitedDischargesExplosiveorfirehazard<140flashpointpH<5Heat>104FradioactiveStormwater,coolingwater,groundwater,unpollutedOilandGrease(O&G):300mg/lCadmium:1.5mg/lCopper:6.0mg/lLead:2.0mg/lNickel:4.0mg/lSilver:5.8mg/lZinc:8.0mg/lCyanide:5.0mg/lMMSDChapter11

ProhibitedDis25SOURCESOFWASTEWATERPartscleaningPartsrinsingProcessbathsFloorwashProcesssystemcleaning/washingVibratorycleanContactcoolingPerformancetestingLeakageAirPollutionControlBlowdownBackwashSOURCESOFWASTEWATERPartscle26SOURCESOFWASTEWATER40CFR433MetalFinishing“BigSix”ElectroplatingElectrolessplatingAnodizingCoating:chromating,phosphating,metalcoloring,passaviting.EtchingandchemicalmillingPrintedcircuitboardmanufacturingSOURCESOFWASTEWATER40CFR4327SOURCESOFWASTEWATER40CFR464:MetalMoldingandCastingSubcategoriesforaluminum,zinc,ferrousProcessesQuenchingCleaningManufacturingsystemleakageHeattreatingContactcoolingMassbaseddischargelimitsSOURCESOFWASTEWATER40CFR4628污水零排放技术FET-WWTO-AM课件29SOURCESOFWASTEWATERISSUESOFCONCERNSegregatingwastestreams,i.e.,cyanide,hexchromeBypasstreatmentBatchdumpEqualizationProductionscheduleSpecialconditionsSOURCESOFWASTEWATERISSUESOF30SOURCESOFWATERWATERMANAGEMENTTOOLS:ProcessschematicFlowsandloadsDumpscheduleQualitydriven/productionissuesPretreatmentatsourceMaintenanceImprovementsSOURCESOFWATERWATERMANAGEME31污水零排放技术FET-WWTO-AM课件32MaterialSafetyDataSheets(MSDS)ExplanationofformTable1intextSectionISectionII–HazardousIngredients/IdentifyInformationHazardouscomponentsTLVPELSectionIII–Physical/ChemicalCharacteristicsBoilingpointVaporpressureVapordensitySpecificgravityMeltingpointEvaporationrateSolubilityinwaterAppearanceandodorMaterialSafetyDataSheets(M33MSDSSectionV–ReactivityDataStability,incompatibility,hazardousdecomposition,hazardouspolymerizationSectionVI–HealthHazardDataRoutesofEntry,acuteandchronic,carcinogenicity,signsandsymptomsofexposure,medicalconditionsgenerallyaggravated,emergencyandfirstaidSectionVII–Precautionsforsafehandlingorstorage,otherSectionVIII–ControlMeasuresRespiratory,ventilation,protectivegloves,eyeprotection,otherPPE,work/hygienepracticesMSDSSectionV–ReactivityDat34MSDS

USEFULINFORMATIONKnowledgeandunderstandriskEmergenciesEnvironmentalreportingDiagnosingasituationMSDS

USEFULINFORMATIONKnowled35EMPLOYEERIGHT-TO-KNOWOSHAHazComStandard–29CFR1910.1200NeedNotificationTrainingAccesstorecordsExposureandmedicalrecordsLimitationsRefusaltoworkLiabilityNoticeEMPLOYEERIGHT-TO-KNOWOSHAHaz36ARITHMETICPROBELMSAppendixIIIStepsinproblemsolvingConversionfactorsVolumePercentremovalorefficiencyLoadingExampleproblemsARITHMETICPROBELMSAppendixII37STEPSINPROBLEMSOLVINGStep1

Whatdoestheproblemtellyou? A.Readtheproblemtwice,underliningthekeywordsanddataB.DrawapictureofthesituationC.LabelthepicturewiththegiveninformationStep2

Whatdoestheproblemask? A.Determinefromtheproblemandpicturetheunknownyouaretryingtofind. B.SelecttheformulawhichsolvesfortheunknownStep3

Determinethesolution(Worktheproblem) A.Writedownselectedformula B.Plugininformationfromproblemandpicture C.Checkunitsofconversions D.Computethesolution E.CheckyourresultsSTEPSINPROBLEMSOLVINGStep138CONVERSIONFACTORS:Arelationshipbywhichyoucanexpressaquantityindifferentunits.Length:1foot=12inchesArea(A):1sq.yd.=9sq.ft.Volume(V):1cu.ft.=7.48galWeight:1gal=8.34lbsofwaterVelocity:1ft/secFlow(Q):=AxVgpmormgdormlpersecond=1cu.ft/sec=7.48gal/sec=449gal/minMetric(liters,grams)vs.English(gallons,pounds)CONVERSIONFACTORS:Arelations39VOLUMEVolume=(AreaxDepth)or(AreaXHeight)RectangularSolidsVolume=LxWxHTank4’x2’x2’=16cuft.16cu.ft.x7.48gal/cu.ft.=120galCylindersVolume=AxHTank30ft.dia.,10fthighπxr2xH3.14x15x15x10=7065cu.ft.=52,846galVOLUMEVolume=(AreaxDepth)40PROBLEMWhatisthedetentiontimeinaclarifierthathasadiameterof40feet,adepthoffluidof12feet,andaflowrateof1.3MGD?PROBLEMWhatisthedetentiont41PERCENT(%)REMOVALOREFFICIENCYDefinition:Theportionofpollutantsremovedinaprocess(unit)expressedasapercentageofwhatgoesintotheprocess(unit). %Removal=(In–Out/In)X100 Removed=In–OutImportanceCalculationsoftreatmentunitofplantefficiencyused.PERCENT(%)REMOVALOREFFICIE42SAMPLEPROBLEM

Atankhasaninfluentsuspendedsolids(SS)concentrationof100mg/LandaneffluentSSconcentrationof60mg/L.Whatisthepercent(%)reductioninsuspendedsolidsinthetank?SAMPLEPROBLEMAtankhasani43SAMPLEPROBLEMBREAKDOWN%removal=In-Out/InX100%removal=100-60/100X100%removal=40%SAMPLEPROBLEMBREAKDOWN%remo44LOADING:Definition

Loadingistheamountofpollutantthatatreatmentunitorplantreceives.Itisnormallyexpressedaspoundsperday(lb/day).Load(lb/day)=Concentration(mg/LorPPM)xFlow(MGD)x8.34Theloadingformulaistheonlyformulathatthetermsmultipliedtogetherdon’tcancel.Butaslongastheconcentrationismg/LismultipliedbytheflowinMDGandisthenmultipliedby8.34,theanswerwillbelbs/day.Mg/LismilligramsperliterPPMispartspermillionMGDismilliongallonsperdayImportanceLoadingisabasicdesignconsiderationforatreatmentsystem.Itdeterminesthebasicsizeandtypeoftreatment.Computationofamount(pounds)ofchlorineneededperdayoramount(cubicfeet)ofairneededinanaerationtank.Assessmentofpaymentonusercharges.

LOADING:Definition45SAMPLEPROBLEM

Atreatmentplantreceivesarawwastewaterflowof100,000gallonsperdaywithanaverageinfluentZincconcentrationof300milligramsperliter(mg/L).WhatistheZincloadinguponthefacility?Loadinginpoundsperday?Given:concentration=300mg/l,flow=0.1mgdLoading=concentrationxMGDx8.34Loading=300mg/lx0.1MGDx8.34=250lbs/daySAMPLEPROBLEMAtreatmentpla46SAMPLEPROBLEMAnoperatoruses1300poundsofAlumperdayinawastewaterflowof12MGD.WhatistheAlumconcentrationinmg/liter?Given: poundsofAlumused=1300lbsperday wastewaterflow=12mgd(milliongallonsperday)Find: Alumconcentrationinmg/l(milligramsperliter)SAMPLEPROBLEMAnoperatoruses47SolutionUsethe“pounds”formula: pounds/day=QxCx8.34whereQ=wastewaterflowinunitsmgd C=concentrationinunitsmg/l 8.34=conversionfactor8.34lbs/gallonin dilutesteamsystems,wherethespecific gravityiscloseto1.0Substitutein: 1300lbs/day=12mgdxC(mg/L)x8.34RearrangetosolveforC: 1300lbs/day----------------------=C(mg/L)=13mg/Lalum (12mgd)(8.34)SolutionUsethe“pounds”formu48演讲完毕,谢谢观看!演讲完毕,谢谢观看!49FETINDUSTRIALWATEWATEROPERATORTRAININGMETALFINISHING/METALMOLDINGANDCASTINGSESSION1–OCTOBER4,2006RobertPeschel,P.E.(414)643-4150(Sigma)rpeschel@FETINDUSTRIALWATEWATEROPERA50SESSION1IntroductionofCourse/ParticipantsCourseOutlineText:TreatmentofMetalWastestreamsNeedforTreatment(Chapter1)RegulatoryOverviewOpportunitiesSourcesofWastewater(Chapter2)MaterialSafetyDataSheets[MSDS](Chapter3)EmployeeRight-To-Know(Chapter4)ArithmeticProblems(AppendixIII)MethodsofTreatment(Chapter5)BatchandContinuousProcesses(5.0)Neutralization(5.1)CommonMetalsRemoval(5.2)ComplexMetalsRemoval(5.3)ReductionHexChrome(5.4)CyanideDestruction(5.5)SESSION1IntroductionofCours51COURSEOUTLINEOCTOBER4 Introduction/Overview Robert

Peschel RegulatoryOverview BasicMath BasicsofTreatment HexavalentChromeReduction CyanideDestructionMetalsRemoval ExampleCalculations/ProblemsOCTOBER11OilyWasteRemoval ScottHartayControlofSolvents/ToxicOrganicsSludgeTreatment&Disposal

SamplingFlowMeasurements SteveGalewski LaboratorySupport ExampleCalculations/ProblemsOCTOBER18 Operation&Maintenance TBD Equipment&Instrumentation ExampleCalculations/Problems RecoveryTechnologies KennethKaszubowskiOCTOBER25 TourofPretreatmentSystem CourseReview RickFulkCOURSEOUTLINEOCTOBER452NEEDFORTREATMENTREGULATORYOVERVIEWCleanWaterActObjectiveandGoalsPoliciesStructureImportantSectionsNPDESPretreatmentStormwaterNEEDFORTREATMENTREGULATORYO53OBJECTIVEOFCWATorestoreandmaintainthechemical,physical,andbiologicalintegrityofthenation’swaters GOALSOFCWAAchievefishableandswimmablewaterby1983(interim)Eliminatethedischargeofpollutantsintonavigablewatersby1985OBJECTIVEOFCWATorestoreand54NATIONALPOLICIESOFCWAProhibitdischargeoftoxicsintoxicamountsProvidefederalassistancetoconstructPOTWsDevelopandimplementarea-widewastetreatmentmanagementplantsineachstate(208plans)ConductR&DnecessarytodevelopzerodischargetechnologyDevelopprogramstocontrolnon-pointsourcesofpollutionEncouragetheminimizationofpaperworkandinteragencydecisionsNATIONALPOLICIESOFCWAProhib55STRUCTUREOFACTTitle1ResearchandRelatedProgramsTitle2GrantsforPOTWConstructionTitle3StandardsandEnforcementTitle4PermitsandLicensesTitle5GeneralProvisionsTitle6StateRevolvingFundsSTRUCTUREOFACTTitle1Resea56TITLE1

RESEARCHANDRELATEDPROGRAMSObjective,goals,andpoliciesCoordinationbetweenstateandfederalagenciesDevelopresearchprojectsDevelopdemonstrationprojectsDevelopoperatortrainingprogramsDevelopspecificprograms(GLNPO)TITLE1

RESEARCHANDRELATEDP57TITLE2

CONSTRUCTIONGRANTSFederalgrantprogramAuthorizesfundingDefineseligibleprojectsSetsparticipationrequirementsEstablishesplanningprograms(208)EstablishesallotmentformulaTITLE2

CONSTRUCTIONGRANTSFed58TITLE3

STANDARDSANDENFORCEMENTStandardsandstandardsettingproceduresPollutants(priority)DeadlinesVariances&waiversWaterqualitycriteriaInventoriesofwaterqualityMonitoring&recordkeepingEnforcementprogramsSpillsofhazardoussubstancesTITLE3

STANDARDSANDENFORCEM59TITLE4

PERMITSANDLICENSESNPDESpermitsystemDischargercertification/publiccommentDelegationtostatesAnti-backslidingStormwaterdischargesOceandischargesDredge&filloperationsSludgedisposal/managementTITLE4

PERMITSANDLICENSESNP60TITLE5

GENERALPROVISISONSGrantsauthoritytoEPAtocarryoutlawProvideskeydefinitionsCreatesadvisoryboardsCitizenssuitprovisionEmployeeprotectionforreportingviolationsSupplyofgoods&servicestofederalgovernmentPeriodicneedssurveysAmericanIndiantribestreatedlikestatesStateauthorityforNPDES/PretreatmentProgramsTITLE5

GENERALPROVISISONSGra61EFFLUENTLIMITATIONSSourcecategorybasisIndustrialcategoriesTechnologybasedlimitsConventionalandtoxicpollutantsLocallimitsEFFLUENTLIMITATIONSSourcecat62EFFLUENTLIMITATIONSDirectdischarges–NPDESIndirectdischarges–toPOTWExistingsources(3years)Newsources(90days)BPT,BCT,BAT,BADCTConcentrationvs.massEFFLUENTLIMITATIONSDirectdis63STANDARDSBPT-BestPracticableControlTechnology.Currentlyavailable.Subjecttocost-benefitanalysis.(middlegroundbetweenBCTandBAT)BCT-

BestConventionalControlTechnologySubjecttocosteffectivenessstandard.Mustbemetwithinthreeyearsofeffectiveguidelinesor3/89.BAT-

BestAvailableTechnologyEconomicallyAchievable.Deemedachievableunlessplantclosurewouldresult.Mustbeinstalledwithinthreeyearsofguidelineor3/89.BADCT-fornewsources(NSPS).BestAvailableDemonstrableControlTechnologyNSPS-

NewSourcePerformanceStandardsPSNS-

PretreatmentStandardsforNewSourcesPSES-PretreatmentStandardsforExistingSourcesSTANDARDSBPT-BestPracticable64POLLUTANTSConventionalBOD,TSS,pHNon-conventionalAmmoniaToxicsPrioritypollutants(65)MetalsOrganicspesticidesPOLLUTANTSConventional65NPDESPERMITSRequiredforanydischargeof“Pollutant”fromany“PointSource”intoany“WatersoftheU.S.”KeytoenforcingCWAlimitsandstandardsDelegationtoStates(e.g.WPDES)AllowsforpublicinvolvementinpermittingprocessCanbemodifiedforreasonAnti-backslidingprovisionsNPDESPERMITSRequiredforany66PRETREATMENTREGULATIONSOBJECTIVESPreventpass-throughoftoxicstoreceivingwaterPreventinterferencewithPOTWoperationsPreventcontaminationofsludgesProtecthealthandsafetyofworkersPRETREATMENTREGULATIONSOBJEC67PRETREATMENTPROGRAMFRAMEWORKEPAhasprimeresponsibilityDelegationstostateswithapprovedprogramsPOTWs>5MGDmustestablishformalprogramandhavefirsttimeresponsibilityMMSDChapter11POTWs<MGDhavestateorEPAinvolvementPRETREATMENTPROGRAMFRAMEWORK68PRETREATMENTSTANDARDSGeneralprohibitivestandardsFireorexplosionhazardCorrosive,pH<5FlowobstructionSlugloadsHeatToxicgassesorvaporsCategoricalstandardsLocalPOTWlimitsCombinedwastestreamformula[409CFR403.6(e)]Moststringentstandardapplies!PRETREATMENTSTANDARDSGeneral69PRETREATMENTSTANDARDSGeneralprohibitivestandardsFireorexplosionhazardCorrosive,pH<5FlowobstructionSlugloadsHeatToxicgassesorvaporsCategoricalstandardsLocalPOTWlimitsCombinedwastestreamformula[409CFR403.6(e)]Moststringentstandardapplies!PRETREATMENTSTANDARDSGeneral70MAJORINDUSTRIALWASTEPROGRAM(IWP)COMPONENTSSeweruseordinancePermittingproceduresCompliancemonitoringEnforcementFundingmechanismBiennialreviewofeffluentlimitationsMAJORINDUSTRIALWASTEPROGRAM71STORMWATERREGULATIONSMostpointsourcesarenotundercontrolthroughNPDESpermitsWaterwayinheavilypopulatedareasarestillbeingdegradedMoststateshaveidentifiedstormwaterasleadingcauseofimpairmentVariousstudieshaveconfirmedproblemsIllicitConnectionstillexistIllegaldumpingstilloccursCongressionalmandatesSTORMWATERREGULATIONSMostpo72WHAT’SINAPERMITEffective/expirationdatesMonitoringandreportingrequirementLocationFrequencyParameterlimitsParametermonitoringNotificationReportingEnforcementSignatoryrequirementsWHAT’SINAPERMITEffective/ex73MMSDChapter11

ProhibitedDischargesExplosiveorfirehazard<140flashpointpH<5Heat>104FradioactiveStormwater,coolingwater,groundwater,unpollutedOilandGrease(O&G):300mg/lCadmium:1.5mg/lCopper:6.0mg/lLead:2.0mg/lNickel:4.0mg/lSilver:5.8mg/lZinc:8.0mg/lCyanide:5.0mg/lMMSDChapter11

ProhibitedDis74SOURCESOFWASTEWATERPartscleaningPartsrinsingProcessbathsFloorwashProcesssystemcleaning/washingVibratorycleanContactcoolingPerformancetestingLeakageAirPollutionControlBlowdownBackwashSOURCESOFWASTEWATERPartscle75SOURCESOFWASTEWATER40CFR433MetalFinishing“BigSix”ElectroplatingElectrolessplatingAnodizingCoating:chromating,phosphating,metalcoloring,passaviting.EtchingandchemicalmillingPrintedcircuitboardmanufacturingSOURCESOFWASTEWATER40CFR4376SOURCESOFWASTEWATER40CFR464:MetalMoldingandCastingSubcategoriesforaluminum,zinc,ferrousProcessesQuenchingCleaningManufacturingsystemleakageHeattreatingContactcoolingMassbaseddischargelimitsSOURCESOFWASTEWATER40CFR4677污水零排放技术FET-WWTO-AM课件78SOURCESOFWASTEWATERISSUESOFCONCERNSegregatingwastestreams,i.e.,cyanide,hexchromeBypasstreatmentBatchdumpEqualizationProductionscheduleSpecialconditionsSOURCESOFWASTEWATERISSUESOF79SOURCESOFWATERWATERMANAGEMENTTOOLS:ProcessschematicFlowsandloadsDumpscheduleQualitydriven/productionissuesPretreatmentatsourceMaintenanceImprovementsSOURCESOFWATERWATERMANAGEME80污水零排放技术FET-WWTO-AM课件81MaterialSafetyDataSheets(MSDS)ExplanationofformTable1intextSectionISectionII–HazardousIngredients/IdentifyInformationHazardouscomponentsTLVPELSectionIII–Physical/ChemicalCharacteristicsBoilingpointVaporpressureVapordensitySpecificgravityMeltingpointEvaporationrateSolubilityinwaterAppearanceandodorMaterialSafetyDataSheets(M82MSDSSectionV–ReactivityDataStability,incompatibility,hazardousdecomposition,hazardouspolymerizationSectionVI–HealthHazardDataRoutesofEntry,acuteandchronic,carcinogenicity,signsandsymptomsofexposure,medicalconditionsgenerallyaggravated,emergencyandfirstaidSectionVII–Precautionsforsafehandlingorstorage,otherSectionVIII–ControlMeasuresRespiratory,ventilation,protectivegloves,eyeprotection,otherPPE,work/hygienepracticesMSDSSectionV–ReactivityDat83MSDS

USEFULINFORMATIONKnowledgeandunderstandriskEmergenciesEnvironmentalreportingDiagnosingasituationMSDS

USEFULINFORMATIONKnowled84EMPLOYEERIGHT-TO-KNOWOSHAHazComStandard–29CFR1910.1200NeedNotificationTrainingAccesstorecordsExposureandmedicalrecordsLimitationsRefusaltoworkLiabilityNoticeEMPLOYEERIGHT-TO-KNOWOSHAHaz85ARITHMETICPROBELMSAppendixIIIStepsinproblemsolvingConversionfactorsVolumePercentremovalorefficiencyLoadingExampleproblemsARITHMETICPROBELMSAppendixII86STEPSINPROBLEMSOLVINGStep1

Whatdoestheproblemtellyou? A.Readtheproblemtwice,underliningthekeywordsanddataB.DrawapictureofthesituationC.LabelthepicturewiththegiveninformationStep2

Whatdoestheproblemask? A.Determinefromtheproblemandpicturetheunknownyouaretryingtofind. B.SelecttheformulawhichsolvesfortheunknownStep3

Determinethesolution(Worktheproblem) A.Writedownselectedformula B.Plugininformationfromproblemandpicture C.Checkunitsofconversions D.Computethesolution E.CheckyourresultsSTEPSINPROBLEMSOLVINGStep187CONVERSIONFACTORS:Arelationshipbywhichyoucanexpressaquantityindifferentunits.Length:1foot=12inchesArea(A):1sq.yd.=9sq.ft.Volume(V):1cu.ft.=7.48galWeight:1gal=8.34lbsofwaterVelocity:1ft/secFlow(Q):=AxVgpmormgdormlpersecond=1cu.ft/sec=7.48gal/sec=449gal/minMetric(liters,grams)vs.English(gallons,pounds)CONVERSIONFACTORS:Arelations88VOLUMEVolume=(AreaxDepth)or(AreaXHeight)RectangularSolidsVolume=LxWxHTank4’x2’x2’=16cuft.16cu.ft.x7.48gal/cu.ft.=120galCylindersVolume=AxHTank30ft.dia.,10fthighπxr2xH3.14x15x15x10=7065

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论