




版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
FETINDUSTRIALWATEWATEROPERATORTRAININGMETALFINISHING/METALMOLDINGANDCASTINGSESSION1–OCTOBER4,2006RobertPeschel,P.E.(414)643-4150(Sigma)rpeschel@FETINDUSTRIALWATEWATEROPERA1SESSION1IntroductionofCourse/ParticipantsCourseOutlineText:TreatmentofMetalWastestreamsNeedforTreatment(Chapter1)RegulatoryOverviewOpportunitiesSourcesofWastewater(Chapter2)MaterialSafetyDataSheets[MSDS](Chapter3)EmployeeRight-To-Know(Chapter4)ArithmeticProblems(AppendixIII)MethodsofTreatment(Chapter5)BatchandContinuousProcesses(5.0)Neutralization(5.1)CommonMetalsRemoval(5.2)ComplexMetalsRemoval(5.3)ReductionHexChrome(5.4)CyanideDestruction(5.5)SESSION1IntroductionofCours2COURSEOUTLINEOCTOBER4 Introduction/Overview Robert
Peschel RegulatoryOverview BasicMath BasicsofTreatment HexavalentChromeReduction CyanideDestructionMetalsRemoval ExampleCalculations/ProblemsOCTOBER11OilyWasteRemoval ScottHartayControlofSolvents/ToxicOrganicsSludgeTreatment&Disposal
SamplingFlowMeasurements SteveGalewski LaboratorySupport ExampleCalculations/ProblemsOCTOBER18 Operation&Maintenance TBD Equipment&Instrumentation ExampleCalculations/Problems RecoveryTechnologies KennethKaszubowskiOCTOBER25 TourofPretreatmentSystem CourseReview RickFulkCOURSEOUTLINEOCTOBER43NEEDFORTREATMENTREGULATORYOVERVIEWCleanWaterActObjectiveandGoalsPoliciesStructureImportantSectionsNPDESPretreatmentStormwaterNEEDFORTREATMENTREGULATORYO4OBJECTIVEOFCWATorestoreandmaintainthechemical,physical,andbiologicalintegrityofthenation’swaters GOALSOFCWAAchievefishableandswimmablewaterby1983(interim)Eliminatethedischargeofpollutantsintonavigablewatersby1985OBJECTIVEOFCWATorestoreand5NATIONALPOLICIESOFCWAProhibitdischargeoftoxicsintoxicamountsProvidefederalassistancetoconstructPOTWsDevelopandimplementarea-widewastetreatmentmanagementplantsineachstate(208plans)ConductR&DnecessarytodevelopzerodischargetechnologyDevelopprogramstocontrolnon-pointsourcesofpollutionEncouragetheminimizationofpaperworkandinteragencydecisionsNATIONALPOLICIESOFCWAProhib6STRUCTUREOFACTTitle1ResearchandRelatedProgramsTitle2GrantsforPOTWConstructionTitle3StandardsandEnforcementTitle4PermitsandLicensesTitle5GeneralProvisionsTitle6StateRevolvingFundsSTRUCTUREOFACTTitle1Resea7TITLE1
RESEARCHANDRELATEDPROGRAMSObjective,goals,andpoliciesCoordinationbetweenstateandfederalagenciesDevelopresearchprojectsDevelopdemonstrationprojectsDevelopoperatortrainingprogramsDevelopspecificprograms(GLNPO)TITLE1
RESEARCHANDRELATEDP8TITLE2
CONSTRUCTIONGRANTSFederalgrantprogramAuthorizesfundingDefineseligibleprojectsSetsparticipationrequirementsEstablishesplanningprograms(208)EstablishesallotmentformulaTITLE2
CONSTRUCTIONGRANTSFed9TITLE3
STANDARDSANDENFORCEMENTStandardsandstandardsettingproceduresPollutants(priority)DeadlinesVariances&waiversWaterqualitycriteriaInventoriesofwaterqualityMonitoring&recordkeepingEnforcementprogramsSpillsofhazardoussubstancesTITLE3
STANDARDSANDENFORCEM10TITLE4
PERMITSANDLICENSESNPDESpermitsystemDischargercertification/publiccommentDelegationtostatesAnti-backslidingStormwaterdischargesOceandischargesDredge&filloperationsSludgedisposal/managementTITLE4
PERMITSANDLICENSESNP11TITLE5
GENERALPROVISISONSGrantsauthoritytoEPAtocarryoutlawProvideskeydefinitionsCreatesadvisoryboardsCitizenssuitprovisionEmployeeprotectionforreportingviolationsSupplyofgoods&servicestofederalgovernmentPeriodicneedssurveysAmericanIndiantribestreatedlikestatesStateauthorityforNPDES/PretreatmentProgramsTITLE5
GENERALPROVISISONSGra12EFFLUENTLIMITATIONSSourcecategorybasisIndustrialcategoriesTechnologybasedlimitsConventionalandtoxicpollutantsLocallimitsEFFLUENTLIMITATIONSSourcecat13EFFLUENTLIMITATIONSDirectdischarges–NPDESIndirectdischarges–toPOTWExistingsources(3years)Newsources(90days)BPT,BCT,BAT,BADCTConcentrationvs.massEFFLUENTLIMITATIONSDirectdis14STANDARDSBPT-BestPracticableControlTechnology.Currentlyavailable.Subjecttocost-benefitanalysis.(middlegroundbetweenBCTandBAT)BCT-
BestConventionalControlTechnologySubjecttocosteffectivenessstandard.Mustbemetwithinthreeyearsofeffectiveguidelinesor3/89.BAT-
BestAvailableTechnologyEconomicallyAchievable.Deemedachievableunlessplantclosurewouldresult.Mustbeinstalledwithinthreeyearsofguidelineor3/89.BADCT-fornewsources(NSPS).BestAvailableDemonstrableControlTechnologyNSPS-
NewSourcePerformanceStandardsPSNS-
PretreatmentStandardsforNewSourcesPSES-PretreatmentStandardsforExistingSourcesSTANDARDSBPT-BestPracticable15POLLUTANTSConventionalBOD,TSS,pHNon-conventionalAmmoniaToxicsPrioritypollutants(65)MetalsOrganicspesticidesPOLLUTANTSConventional16NPDESPERMITSRequiredforanydischargeof“Pollutant”fromany“PointSource”intoany“WatersoftheU.S.”KeytoenforcingCWAlimitsandstandardsDelegationtoStates(e.g.WPDES)AllowsforpublicinvolvementinpermittingprocessCanbemodifiedforreasonAnti-backslidingprovisionsNPDESPERMITSRequiredforany17PRETREATMENTREGULATIONSOBJECTIVESPreventpass-throughoftoxicstoreceivingwaterPreventinterferencewithPOTWoperationsPreventcontaminationofsludgesProtecthealthandsafetyofworkersPRETREATMENTREGULATIONSOBJEC18PRETREATMENTPROGRAMFRAMEWORKEPAhasprimeresponsibilityDelegationstostateswithapprovedprogramsPOTWs>5MGDmustestablishformalprogramandhavefirsttimeresponsibilityMMSDChapter11POTWs<MGDhavestateorEPAinvolvementPRETREATMENTPROGRAMFRAMEWORK19PRETREATMENTSTANDARDSGeneralprohibitivestandardsFireorexplosionhazardCorrosive,pH<5FlowobstructionSlugloadsHeatToxicgassesorvaporsCategoricalstandardsLocalPOTWlimitsCombinedwastestreamformula[409CFR403.6(e)]Moststringentstandardapplies!PRETREATMENTSTANDARDSGeneral20PRETREATMENTSTANDARDSGeneralprohibitivestandardsFireorexplosionhazardCorrosive,pH<5FlowobstructionSlugloadsHeatToxicgassesorvaporsCategoricalstandardsLocalPOTWlimitsCombinedwastestreamformula[409CFR403.6(e)]Moststringentstandardapplies!PRETREATMENTSTANDARDSGeneral21MAJORINDUSTRIALWASTEPROGRAM(IWP)COMPONENTSSeweruseordinancePermittingproceduresCompliancemonitoringEnforcementFundingmechanismBiennialreviewofeffluentlimitationsMAJORINDUSTRIALWASTEPROGRAM22STORMWATERREGULATIONSMostpointsourcesarenotundercontrolthroughNPDESpermitsWaterwayinheavilypopulatedareasarestillbeingdegradedMoststateshaveidentifiedstormwaterasleadingcauseofimpairmentVariousstudieshaveconfirmedproblemsIllicitConnectionstillexistIllegaldumpingstilloccursCongressionalmandatesSTORMWATERREGULATIONSMostpo23WHAT’SINAPERMITEffective/expirationdatesMonitoringandreportingrequirementLocationFrequencyParameterlimitsParametermonitoringNotificationReportingEnforcementSignatoryrequirementsWHAT’SINAPERMITEffective/ex24MMSDChapter11
ProhibitedDischargesExplosiveorfirehazard<140flashpointpH<5Heat>104FradioactiveStormwater,coolingwater,groundwater,unpollutedOilandGrease(O&G):300mg/lCadmium:1.5mg/lCopper:6.0mg/lLead:2.0mg/lNickel:4.0mg/lSilver:5.8mg/lZinc:8.0mg/lCyanide:5.0mg/lMMSDChapter11
ProhibitedDis25SOURCESOFWASTEWATERPartscleaningPartsrinsingProcessbathsFloorwashProcesssystemcleaning/washingVibratorycleanContactcoolingPerformancetestingLeakageAirPollutionControlBlowdownBackwashSOURCESOFWASTEWATERPartscle26SOURCESOFWASTEWATER40CFR433MetalFinishing“BigSix”ElectroplatingElectrolessplatingAnodizingCoating:chromating,phosphating,metalcoloring,passaviting.EtchingandchemicalmillingPrintedcircuitboardmanufacturingSOURCESOFWASTEWATER40CFR4327SOURCESOFWASTEWATER40CFR464:MetalMoldingandCastingSubcategoriesforaluminum,zinc,ferrousProcessesQuenchingCleaningManufacturingsystemleakageHeattreatingContactcoolingMassbaseddischargelimitsSOURCESOFWASTEWATER40CFR4628污水零排放技术FET-WWTO-AM课件29SOURCESOFWASTEWATERISSUESOFCONCERNSegregatingwastestreams,i.e.,cyanide,hexchromeBypasstreatmentBatchdumpEqualizationProductionscheduleSpecialconditionsSOURCESOFWASTEWATERISSUESOF30SOURCESOFWATERWATERMANAGEMENTTOOLS:ProcessschematicFlowsandloadsDumpscheduleQualitydriven/productionissuesPretreatmentatsourceMaintenanceImprovementsSOURCESOFWATERWATERMANAGEME31污水零排放技术FET-WWTO-AM课件32MaterialSafetyDataSheets(MSDS)ExplanationofformTable1intextSectionISectionII–HazardousIngredients/IdentifyInformationHazardouscomponentsTLVPELSectionIII–Physical/ChemicalCharacteristicsBoilingpointVaporpressureVapordensitySpecificgravityMeltingpointEvaporationrateSolubilityinwaterAppearanceandodorMaterialSafetyDataSheets(M33MSDSSectionV–ReactivityDataStability,incompatibility,hazardousdecomposition,hazardouspolymerizationSectionVI–HealthHazardDataRoutesofEntry,acuteandchronic,carcinogenicity,signsandsymptomsofexposure,medicalconditionsgenerallyaggravated,emergencyandfirstaidSectionVII–Precautionsforsafehandlingorstorage,otherSectionVIII–ControlMeasuresRespiratory,ventilation,protectivegloves,eyeprotection,otherPPE,work/hygienepracticesMSDSSectionV–ReactivityDat34MSDS
USEFULINFORMATIONKnowledgeandunderstandriskEmergenciesEnvironmentalreportingDiagnosingasituationMSDS
USEFULINFORMATIONKnowled35EMPLOYEERIGHT-TO-KNOWOSHAHazComStandard–29CFR1910.1200NeedNotificationTrainingAccesstorecordsExposureandmedicalrecordsLimitationsRefusaltoworkLiabilityNoticeEMPLOYEERIGHT-TO-KNOWOSHAHaz36ARITHMETICPROBELMSAppendixIIIStepsinproblemsolvingConversionfactorsVolumePercentremovalorefficiencyLoadingExampleproblemsARITHMETICPROBELMSAppendixII37STEPSINPROBLEMSOLVINGStep1
Whatdoestheproblemtellyou? A.Readtheproblemtwice,underliningthekeywordsanddataB.DrawapictureofthesituationC.LabelthepicturewiththegiveninformationStep2
Whatdoestheproblemask? A.Determinefromtheproblemandpicturetheunknownyouaretryingtofind. B.SelecttheformulawhichsolvesfortheunknownStep3
Determinethesolution(Worktheproblem) A.Writedownselectedformula B.Plugininformationfromproblemandpicture C.Checkunitsofconversions D.Computethesolution E.CheckyourresultsSTEPSINPROBLEMSOLVINGStep138CONVERSIONFACTORS:Arelationshipbywhichyoucanexpressaquantityindifferentunits.Length:1foot=12inchesArea(A):1sq.yd.=9sq.ft.Volume(V):1cu.ft.=7.48galWeight:1gal=8.34lbsofwaterVelocity:1ft/secFlow(Q):=AxVgpmormgdormlpersecond=1cu.ft/sec=7.48gal/sec=449gal/minMetric(liters,grams)vs.English(gallons,pounds)CONVERSIONFACTORS:Arelations39VOLUMEVolume=(AreaxDepth)or(AreaXHeight)RectangularSolidsVolume=LxWxHTank4’x2’x2’=16cuft.16cu.ft.x7.48gal/cu.ft.=120galCylindersVolume=AxHTank30ft.dia.,10fthighπxr2xH3.14x15x15x10=7065cu.ft.=52,846galVOLUMEVolume=(AreaxDepth)40PROBLEMWhatisthedetentiontimeinaclarifierthathasadiameterof40feet,adepthoffluidof12feet,andaflowrateof1.3MGD?PROBLEMWhatisthedetentiont41PERCENT(%)REMOVALOREFFICIENCYDefinition:Theportionofpollutantsremovedinaprocess(unit)expressedasapercentageofwhatgoesintotheprocess(unit). %Removal=(In–Out/In)X100 Removed=In–OutImportanceCalculationsoftreatmentunitofplantefficiencyused.PERCENT(%)REMOVALOREFFICIE42SAMPLEPROBLEM
Atankhasaninfluentsuspendedsolids(SS)concentrationof100mg/LandaneffluentSSconcentrationof60mg/L.Whatisthepercent(%)reductioninsuspendedsolidsinthetank?SAMPLEPROBLEMAtankhasani43SAMPLEPROBLEMBREAKDOWN%removal=In-Out/InX100%removal=100-60/100X100%removal=40%SAMPLEPROBLEMBREAKDOWN%remo44LOADING:Definition
Loadingistheamountofpollutantthatatreatmentunitorplantreceives.Itisnormallyexpressedaspoundsperday(lb/day).Load(lb/day)=Concentration(mg/LorPPM)xFlow(MGD)x8.34Theloadingformulaistheonlyformulathatthetermsmultipliedtogetherdon’tcancel.Butaslongastheconcentrationismg/LismultipliedbytheflowinMDGandisthenmultipliedby8.34,theanswerwillbelbs/day.Mg/LismilligramsperliterPPMispartspermillionMGDismilliongallonsperdayImportanceLoadingisabasicdesignconsiderationforatreatmentsystem.Itdeterminesthebasicsizeandtypeoftreatment.Computationofamount(pounds)ofchlorineneededperdayoramount(cubicfeet)ofairneededinanaerationtank.Assessmentofpaymentonusercharges.
LOADING:Definition45SAMPLEPROBLEM
Atreatmentplantreceivesarawwastewaterflowof100,000gallonsperdaywithanaverageinfluentZincconcentrationof300milligramsperliter(mg/L).WhatistheZincloadinguponthefacility?Loadinginpoundsperday?Given:concentration=300mg/l,flow=0.1mgdLoading=concentrationxMGDx8.34Loading=300mg/lx0.1MGDx8.34=250lbs/daySAMPLEPROBLEMAtreatmentpla46SAMPLEPROBLEMAnoperatoruses1300poundsofAlumperdayinawastewaterflowof12MGD.WhatistheAlumconcentrationinmg/liter?Given: poundsofAlumused=1300lbsperday wastewaterflow=12mgd(milliongallonsperday)Find: Alumconcentrationinmg/l(milligramsperliter)SAMPLEPROBLEMAnoperatoruses47SolutionUsethe“pounds”formula: pounds/day=QxCx8.34whereQ=wastewaterflowinunitsmgd C=concentrationinunitsmg/l 8.34=conversionfactor8.34lbs/gallonin dilutesteamsystems,wherethespecific gravityiscloseto1.0Substitutein: 1300lbs/day=12mgdxC(mg/L)x8.34RearrangetosolveforC: 1300lbs/day----------------------=C(mg/L)=13mg/Lalum (12mgd)(8.34)SolutionUsethe“pounds”formu48演讲完毕,谢谢观看!演讲完毕,谢谢观看!49FETINDUSTRIALWATEWATEROPERATORTRAININGMETALFINISHING/METALMOLDINGANDCASTINGSESSION1–OCTOBER4,2006RobertPeschel,P.E.(414)643-4150(Sigma)rpeschel@FETINDUSTRIALWATEWATEROPERA50SESSION1IntroductionofCourse/ParticipantsCourseOutlineText:TreatmentofMetalWastestreamsNeedforTreatment(Chapter1)RegulatoryOverviewOpportunitiesSourcesofWastewater(Chapter2)MaterialSafetyDataSheets[MSDS](Chapter3)EmployeeRight-To-Know(Chapter4)ArithmeticProblems(AppendixIII)MethodsofTreatment(Chapter5)BatchandContinuousProcesses(5.0)Neutralization(5.1)CommonMetalsRemoval(5.2)ComplexMetalsRemoval(5.3)ReductionHexChrome(5.4)CyanideDestruction(5.5)SESSION1IntroductionofCours51COURSEOUTLINEOCTOBER4 Introduction/Overview Robert
Peschel RegulatoryOverview BasicMath BasicsofTreatment HexavalentChromeReduction CyanideDestructionMetalsRemoval ExampleCalculations/ProblemsOCTOBER11OilyWasteRemoval ScottHartayControlofSolvents/ToxicOrganicsSludgeTreatment&Disposal
SamplingFlowMeasurements SteveGalewski LaboratorySupport ExampleCalculations/ProblemsOCTOBER18 Operation&Maintenance TBD Equipment&Instrumentation ExampleCalculations/Problems RecoveryTechnologies KennethKaszubowskiOCTOBER25 TourofPretreatmentSystem CourseReview RickFulkCOURSEOUTLINEOCTOBER452NEEDFORTREATMENTREGULATORYOVERVIEWCleanWaterActObjectiveandGoalsPoliciesStructureImportantSectionsNPDESPretreatmentStormwaterNEEDFORTREATMENTREGULATORYO53OBJECTIVEOFCWATorestoreandmaintainthechemical,physical,andbiologicalintegrityofthenation’swaters GOALSOFCWAAchievefishableandswimmablewaterby1983(interim)Eliminatethedischargeofpollutantsintonavigablewatersby1985OBJECTIVEOFCWATorestoreand54NATIONALPOLICIESOFCWAProhibitdischargeoftoxicsintoxicamountsProvidefederalassistancetoconstructPOTWsDevelopandimplementarea-widewastetreatmentmanagementplantsineachstate(208plans)ConductR&DnecessarytodevelopzerodischargetechnologyDevelopprogramstocontrolnon-pointsourcesofpollutionEncouragetheminimizationofpaperworkandinteragencydecisionsNATIONALPOLICIESOFCWAProhib55STRUCTUREOFACTTitle1ResearchandRelatedProgramsTitle2GrantsforPOTWConstructionTitle3StandardsandEnforcementTitle4PermitsandLicensesTitle5GeneralProvisionsTitle6StateRevolvingFundsSTRUCTUREOFACTTitle1Resea56TITLE1
RESEARCHANDRELATEDPROGRAMSObjective,goals,andpoliciesCoordinationbetweenstateandfederalagenciesDevelopresearchprojectsDevelopdemonstrationprojectsDevelopoperatortrainingprogramsDevelopspecificprograms(GLNPO)TITLE1
RESEARCHANDRELATEDP57TITLE2
CONSTRUCTIONGRANTSFederalgrantprogramAuthorizesfundingDefineseligibleprojectsSetsparticipationrequirementsEstablishesplanningprograms(208)EstablishesallotmentformulaTITLE2
CONSTRUCTIONGRANTSFed58TITLE3
STANDARDSANDENFORCEMENTStandardsandstandardsettingproceduresPollutants(priority)DeadlinesVariances&waiversWaterqualitycriteriaInventoriesofwaterqualityMonitoring&recordkeepingEnforcementprogramsSpillsofhazardoussubstancesTITLE3
STANDARDSANDENFORCEM59TITLE4
PERMITSANDLICENSESNPDESpermitsystemDischargercertification/publiccommentDelegationtostatesAnti-backslidingStormwaterdischargesOceandischargesDredge&filloperationsSludgedisposal/managementTITLE4
PERMITSANDLICENSESNP60TITLE5
GENERALPROVISISONSGrantsauthoritytoEPAtocarryoutlawProvideskeydefinitionsCreatesadvisoryboardsCitizenssuitprovisionEmployeeprotectionforreportingviolationsSupplyofgoods&servicestofederalgovernmentPeriodicneedssurveysAmericanIndiantribestreatedlikestatesStateauthorityforNPDES/PretreatmentProgramsTITLE5
GENERALPROVISISONSGra61EFFLUENTLIMITATIONSSourcecategorybasisIndustrialcategoriesTechnologybasedlimitsConventionalandtoxicpollutantsLocallimitsEFFLUENTLIMITATIONSSourcecat62EFFLUENTLIMITATIONSDirectdischarges–NPDESIndirectdischarges–toPOTWExistingsources(3years)Newsources(90days)BPT,BCT,BAT,BADCTConcentrationvs.massEFFLUENTLIMITATIONSDirectdis63STANDARDSBPT-BestPracticableControlTechnology.Currentlyavailable.Subjecttocost-benefitanalysis.(middlegroundbetweenBCTandBAT)BCT-
BestConventionalControlTechnologySubjecttocosteffectivenessstandard.Mustbemetwithinthreeyearsofeffectiveguidelinesor3/89.BAT-
BestAvailableTechnologyEconomicallyAchievable.Deemedachievableunlessplantclosurewouldresult.Mustbeinstalledwithinthreeyearsofguidelineor3/89.BADCT-fornewsources(NSPS).BestAvailableDemonstrableControlTechnologyNSPS-
NewSourcePerformanceStandardsPSNS-
PretreatmentStandardsforNewSourcesPSES-PretreatmentStandardsforExistingSourcesSTANDARDSBPT-BestPracticable64POLLUTANTSConventionalBOD,TSS,pHNon-conventionalAmmoniaToxicsPrioritypollutants(65)MetalsOrganicspesticidesPOLLUTANTSConventional65NPDESPERMITSRequiredforanydischargeof“Pollutant”fromany“PointSource”intoany“WatersoftheU.S.”KeytoenforcingCWAlimitsandstandardsDelegationtoStates(e.g.WPDES)AllowsforpublicinvolvementinpermittingprocessCanbemodifiedforreasonAnti-backslidingprovisionsNPDESPERMITSRequiredforany66PRETREATMENTREGULATIONSOBJECTIVESPreventpass-throughoftoxicstoreceivingwaterPreventinterferencewithPOTWoperationsPreventcontaminationofsludgesProtecthealthandsafetyofworkersPRETREATMENTREGULATIONSOBJEC67PRETREATMENTPROGRAMFRAMEWORKEPAhasprimeresponsibilityDelegationstostateswithapprovedprogramsPOTWs>5MGDmustestablishformalprogramandhavefirsttimeresponsibilityMMSDChapter11POTWs<MGDhavestateorEPAinvolvementPRETREATMENTPROGRAMFRAMEWORK68PRETREATMENTSTANDARDSGeneralprohibitivestandardsFireorexplosionhazardCorrosive,pH<5FlowobstructionSlugloadsHeatToxicgassesorvaporsCategoricalstandardsLocalPOTWlimitsCombinedwastestreamformula[409CFR403.6(e)]Moststringentstandardapplies!PRETREATMENTSTANDARDSGeneral69PRETREATMENTSTANDARDSGeneralprohibitivestandardsFireorexplosionhazardCorrosive,pH<5FlowobstructionSlugloadsHeatToxicgassesorvaporsCategoricalstandardsLocalPOTWlimitsCombinedwastestreamformula[409CFR403.6(e)]Moststringentstandardapplies!PRETREATMENTSTANDARDSGeneral70MAJORINDUSTRIALWASTEPROGRAM(IWP)COMPONENTSSeweruseordinancePermittingproceduresCompliancemonitoringEnforcementFundingmechanismBiennialreviewofeffluentlimitationsMAJORINDUSTRIALWASTEPROGRAM71STORMWATERREGULATIONSMostpointsourcesarenotundercontrolthroughNPDESpermitsWaterwayinheavilypopulatedareasarestillbeingdegradedMoststateshaveidentifiedstormwaterasleadingcauseofimpairmentVariousstudieshaveconfirmedproblemsIllicitConnectionstillexistIllegaldumpingstilloccursCongressionalmandatesSTORMWATERREGULATIONSMostpo72WHAT’SINAPERMITEffective/expirationdatesMonitoringandreportingrequirementLocationFrequencyParameterlimitsParametermonitoringNotificationReportingEnforcementSignatoryrequirementsWHAT’SINAPERMITEffective/ex73MMSDChapter11
ProhibitedDischargesExplosiveorfirehazard<140flashpointpH<5Heat>104FradioactiveStormwater,coolingwater,groundwater,unpollutedOilandGrease(O&G):300mg/lCadmium:1.5mg/lCopper:6.0mg/lLead:2.0mg/lNickel:4.0mg/lSilver:5.8mg/lZinc:8.0mg/lCyanide:5.0mg/lMMSDChapter11
ProhibitedDis74SOURCESOFWASTEWATERPartscleaningPartsrinsingProcessbathsFloorwashProcesssystemcleaning/washingVibratorycleanContactcoolingPerformancetestingLeakageAirPollutionControlBlowdownBackwashSOURCESOFWASTEWATERPartscle75SOURCESOFWASTEWATER40CFR433MetalFinishing“BigSix”ElectroplatingElectrolessplatingAnodizingCoating:chromating,phosphating,metalcoloring,passaviting.EtchingandchemicalmillingPrintedcircuitboardmanufacturingSOURCESOFWASTEWATER40CFR4376SOURCESOFWASTEWATER40CFR464:MetalMoldingandCastingSubcategoriesforaluminum,zinc,ferrousProcessesQuenchingCleaningManufacturingsystemleakageHeattreatingContactcoolingMassbaseddischargelimitsSOURCESOFWASTEWATER40CFR4677污水零排放技术FET-WWTO-AM课件78SOURCESOFWASTEWATERISSUESOFCONCERNSegregatingwastestreams,i.e.,cyanide,hexchromeBypasstreatmentBatchdumpEqualizationProductionscheduleSpecialconditionsSOURCESOFWASTEWATERISSUESOF79SOURCESOFWATERWATERMANAGEMENTTOOLS:ProcessschematicFlowsandloadsDumpscheduleQualitydriven/productionissuesPretreatmentatsourceMaintenanceImprovementsSOURCESOFWATERWATERMANAGEME80污水零排放技术FET-WWTO-AM课件81MaterialSafetyDataSheets(MSDS)ExplanationofformTable1intextSectionISectionII–HazardousIngredients/IdentifyInformationHazardouscomponentsTLVPELSectionIII–Physical/ChemicalCharacteristicsBoilingpointVaporpressureVapordensitySpecificgravityMeltingpointEvaporationrateSolubilityinwaterAppearanceandodorMaterialSafetyDataSheets(M82MSDSSectionV–ReactivityDataStability,incompatibility,hazardousdecomposition,hazardouspolymerizationSectionVI–HealthHazardDataRoutesofEntry,acuteandchronic,carcinogenicity,signsandsymptomsofexposure,medicalconditionsgenerallyaggravated,emergencyandfirstaidSectionVII–Precautionsforsafehandlingorstorage,otherSectionVIII–ControlMeasuresRespiratory,ventilation,protectivegloves,eyeprotection,otherPPE,work/hygienepracticesMSDSSectionV–ReactivityDat83MSDS
USEFULINFORMATIONKnowledgeandunderstandriskEmergenciesEnvironmentalreportingDiagnosingasituationMSDS
USEFULINFORMATIONKnowled84EMPLOYEERIGHT-TO-KNOWOSHAHazComStandard–29CFR1910.1200NeedNotificationTrainingAccesstorecordsExposureandmedicalrecordsLimitationsRefusaltoworkLiabilityNoticeEMPLOYEERIGHT-TO-KNOWOSHAHaz85ARITHMETICPROBELMSAppendixIIIStepsinproblemsolvingConversionfactorsVolumePercentremovalorefficiencyLoadingExampleproblemsARITHMETICPROBELMSAppendixII86STEPSINPROBLEMSOLVINGStep1
Whatdoestheproblemtellyou? A.Readtheproblemtwice,underliningthekeywordsanddataB.DrawapictureofthesituationC.LabelthepicturewiththegiveninformationStep2
Whatdoestheproblemask? A.Determinefromtheproblemandpicturetheunknownyouaretryingtofind. B.SelecttheformulawhichsolvesfortheunknownStep3
Determinethesolution(Worktheproblem) A.Writedownselectedformula B.Plugininformationfromproblemandpicture C.Checkunitsofconversions D.Computethesolution E.CheckyourresultsSTEPSINPROBLEMSOLVINGStep187CONVERSIONFACTORS:Arelationshipbywhichyoucanexpressaquantityindifferentunits.Length:1foot=12inchesArea(A):1sq.yd.=9sq.ft.Volume(V):1cu.ft.=7.48galWeight:1gal=8.34lbsofwaterVelocity:1ft/secFlow(Q):=AxVgpmormgdormlpersecond=1cu.ft/sec=7.48gal/sec=449gal/minMetric(liters,grams)vs.English(gallons,pounds)CONVERSIONFACTORS:Arelations88VOLUMEVolume=(AreaxDepth)or(AreaXHeight)RectangularSolidsVolume=LxWxHTank4’x2’x2’=16cuft.16cu.ft.x7.48gal/cu.ft.=120galCylindersVolume=AxHTank30ft.dia.,10fthighπxr2xH3.14x15x15x10=7065
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 加强药物注册申报资料真实性核查
- 房屋内外装修合同
- 骨科护理读书报告
- 房地产面积测绘合同协议书
- 设备销售代理合同
- 拖车服务协议合同
- 机械要素考试题库及答案
- 潍坊市电梯安全管理人员综合测评样题及答案
- 投资公司融资合作合同书
- 会展服务合同
- 第15课《青春之光》课件-2024-2025学年统编版语文七年级下册
- 中考语文古诗欣赏试题汇编(课内古诗比较阅读)(截至2024)
- 云梯车作业交底
- 《孙权劝学》历年中考文言文阅读试题40篇(含答案与翻译)(截至2024年)
- 新型可瓷化膨胀防火涂料的制备及性能研究
- DB11-T 367-2021 地下室防水技术规程
- 《机械设计课程设计》课程标准
- 2025年贵州高速集团有限公司招聘笔试参考题库含答案解析
- 2025版融资租赁合同履行监管服务合同3篇
- 肺结核防治知识培训课件
- 《基于作业成本法的S公司物流成本分析研究》8300字(论文)
评论
0/150
提交评论