1、Experimental class on “ Fuel Cell and ElectrochemistryExperiment setupEquipment: CHI760D electrochemical stationThree electrode system. WE: CE: RE: Saturated Calomel ElectrodeSolution: 1 .0 X 10-3mol/L K 3 Fe (CN) 6 + 0,1M KClLab reportPlot curves of LSV curve, and describe why current changes with
2、sweeping voltage?Reason: Voltage is a driving force to an electrode reactions, it is concerned with the equilibrium of electron transfer at electrode surface. As the altering of applied voltage, the Fermi-level is raised (or lowered), which changing the energy state of the electrons. Making the over
3、all barrier height (ie activation energy) alter as a function of the applied voltage. In this reaction, when voltage is 0.6V, there is no electron transfer, so the current is zero.With the voltage to the more reductive values, the current increases. When the diffusion layer has grown sufficiently ab
4、ove the electrode so that the flux of reactant to the electrode is not fast enough to satisfy that required by Nernst Equation. The peak is obtaining. When the reaction continued, it would get a situation that there will be a lower reactant concentration at the electrode than in bulk solution, that
5、is, the supply of fresh reactant to the surface decreased, so current decreases.Plot the curves of CV curves with different scan rate;0.00006H-600mv/s G-500mv/s F-400mv/s E-300mv/s D-200mv/s C-100mv/s B- 50 mv/s A- 20 mv/s0.000040.000020.00000-0.00002-0.000040.60.40.20.0-0.2-0.4araR nacs0.00006H-600
6、mv/s G-500mv/s F-400mv/s E-300mv/s D-200mv/s C-100mv/s B- 50 mv/s A- 20 mv/s0.000040.000020.00000-0.00002-0.000040.60.40.20.0-0.2-0.4araR nacsPotential/VScan rate (mV/s)2050100200300400500600Peak current (uA)Ipc8.33613.1718.5025.9631.5436.1740.2343.95Ipa-8.263-13.01-18.19-25.26-30.50-34.88-38.68-42.
7、12Ratio of Peak current1.0091.0121.0171.0281.0341.0371.0401.043Peak voltag E(V)V10.1710.1890.1910.1900.1870.1860.1830.183V20.2420.2550.2590.2620.2620.2620.2620.262Peak voltage difference (mV)7166687275767979From the CV curves, fill the table3)4) According to the result, describe why curves shows cer
8、tain trend, and how peak current and peak voltage difference change with scan rate?Answer: From above data and curve, we can obtain:At a fixed scan rate : (1).from initial positive voltage to more reductive values, the current beginto flow, then reach a peak ipc and decrease eventually. (2).when vol
9、tage moves back, the equilibrium positions gradually converting electrolysis product (Fe 2+) back to reactant (Fe 3+), the current flow is from the solution species back to the electrode and so occurs in the oppositesense to the forward. The process has another current peak ipa. It has same reason o
10、f linear sweep voltammetry.At different scan rate, the ratio of peak current ip c/ip a is about equal to 1 (1.009 1.043).At different scan rate, the position of peak voltage do not alter greatly C Ep is about a constant (66-79).mV/s)20501002003004005006001/2V(mV/s) 1/24.4727.0711014.14217.3212022.36
11、124.495Ip (uA)8.33613.1718.5025.9631.5436.1740.2343.95Ep(V)0.1710.1890.1910.1900.1870.1860.1830.183Ep (mV)7166687275767979 Ip-V1/2Figure 1: Peak current VS radical sign of scan rate Interpretation:It is apparent that the peak current is linear to radical sign of scan rate, whichsatisfy this equation
12、: ip = kv 1/2Co.Reason:This can be rationalised by considering the size of the diffusion layer and the time taken to record the scan. Clearly the linear sweep voltammogram will take longer to record as the scan rate is decreased. Therefore the size of the diffusion layer above the electrode surface
13、will be different depending upon the voltage scan rate used. In a slow voltage scan the diffusion layer will grow much further from the electrode in comparison to a fast scan. Consequently the flux to the electrode surface is considerably smaller at slow scan rates than it is at faster rates. As the
14、 current isproportional to the flux towards the electrode, the magnitude of the current will be lower at slow scan rates and higher at high rates.Ep-VFigure 2: Peak potential VS scan rateEp-v1601200 -|1|1|1|-|1-i0100200300400500600700v (mV/s)Figure 3: the change of Peak potential VS scan rateInterpretation: Figure 2: shows that the position of the peak current occurs at the same voltage.Figure 3: shows the Pea
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2027届浙江省富阳市新登镇中学共同体达标名校初中物理毕业考试模拟冲刺卷含解析
- 《汇编第八章》课件
- 2026年陕西事业单位联考职业能力倾向测验真题含答案
- 乐陵康宁医药有限公司培训试题(2026.9月)测试卷及答案
- (正式版)DB61∕T 865-2014 《玉米 益农72》
- 2026年传染病防治寄生虫性传染病模拟试题(含答案)
- 2026年电气节能模拟试题(含答案)
- 《做文明高中生》课件
- 2025-2026年计算机网络与通信技术测试卷
- 2025-2026年天津市人教版高三体育与健康考前冲刺模拟卷
- DB11∕T 2363-2024 医疗机构安宁疗护服务规范
- 纺织企业职业病防护与检测报告
- 《文学理论》第九讲:文学风格、流派与思潮
- 《现代办公事务处理》全套教学课件
- 城市道路清扫保洁与质量评价标准 CJJT126-2022
- 江西省人防工程质量监督管理指导手册(试行)
- 长沙市外墙外保温、外墙内保温、屋面标准图集
- 系列非晶合金干式电力变压器安装使用说明书
- 九年级上册语文理解性默写(含答案)
- 领导干部的法治思维-胡锦光教学课件
- 聚苯硫醚纤维演示文稿
评论
0/150
提交评论