版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1、 Copyright Fresenius Kabi AGJuly 26, 2022LOVO Cell Processing SystemIntroduction to LovoOverview of Spinning Membrane TechnologyProcedure OverviewReview of Laboratory DataProcessing Parameters and FeaturesKit ConfigurationData Management Copyright Fresenius Kabi AGJuly 26, 2022LOVO Cell Processing S
2、ystemAutomated Cell Processing for White Blood Cells:Supernatant or Culture Media ExchangeSupernatant Volume Reduction/ Cell ConcentrationReduction of PlateletsLovo is For Laboratory Use Only and does not have 510(k) clearanceEnables closed system processingLovo is the only cell processing system us
3、ing spinning membrane technology Copyright Fresenius Kabi AGJuly 26, 2022Fresenius Kabi considers the Lovo system for laboratory use and not subject to medical device registration, clearance, or approval by the U.S. Food and Drug Administration (FDA), European Union, Health Canada, or the Australian
4、 Therapeutics Goods Administration. Cells processed on this system that are intended for diagnostic purposes, for direct transfusion, or for use in the production of a therapeutic product(s) or vaccine(s) for clinical use may require advance regulatory clearance or approval, which is the sole respon
5、sibility of the user.LOVO Cell Processing SystemIntroduction to LovoOverview of Spinning Membrane TechnologyProcedure OverviewReview of Laboratory DataProcessing Parameters and FeaturesKit ConfigurationData Management Copyright Fresenius Kabi AGJuly 26, 2022What is Spinning Membrane Filtration?Spinn
6、ing Membrane Technology is used in lieu of a centrifuge to separate supernatant from cellular componentsThe module is single-use and part of the disposable set Copyright Fresenius Kabi AGJuly 26, 2022Cell sourceinput portSupernatantoutput portSupernatantchannelsSpinning Membrane ModuleSpinning Membr
7、ane Module is comprised of three components Copyright Fresenius Kabi AGJuly 26, 2022Rotating Inner RotorFiltration MembraneStationary Cylindrical HousingPolycarbonate Membrane Filtration Utilizes Cell Size DiscriminationFenwal Overview Presentation | 7/26/20227Polycarbonate Membrane4.0 m pore size10
8、 m thicknessEtched, cylindrical poreRetains WBCs and some RBCsApproximate Scale:= RBC= WBC=PLTSEM of Polycarbonate MembraneSpinning Membrane Technology Overview Copyright Fresenius Kabi AGJuly 26, 2022Why Spinning Membrane Technology?Small Volume in the Spinner12 mL capacity Easy Fluid ManagementNo
9、spin-up or down of a centrifugeAble to re-direct cells quicklyNon-Pelletizing to CellsManual re-suspension of cells not necessary Copyright Fresenius Kabi AGJuly 26, 2022SimpleFastQuietLOVO Cell Processing SystemIntroduction to LovoOverview of Spinning Membrane TechnologyProcedure OverviewReview of
10、Laboratory DataProcessing Parameters and FeaturesKit ConfigurationData Management Copyright Fresenius Kabi AGJuly 26, 2022Procedure overviewA typical Lovo procedure consists of a series of wash cycles (number configurable by the operator)Each cycle consists of: Concentration PhaseConcentration ratio
11、s would be modified depending on the type of source and can range from 40:1 to 2:1 (e.g. 10:1 for fresh T-cells, 2:1 for cryopreserved cells)Dilution PhaseFollowing concentration, target cells will be diluted to the original source volume or maximum volume of the in-process container Copyright Frese
12、nius Kabi USAJuly 26, 2022Supernatant Concentration100%Supernatant Volume100 mLWash Media Volume0 mLCell Concentration1xNumber of Cells50Overview of a 2-Wash Cycle Process10:1 Concentration10:1 Concentration1:10 Dilution10:1 Concentration1:10 DilutionSupernatant Concentration10%Supernatant Volume90
13、mLCell Concentration1xNumber of Cells50100%10 mL0 mL10 x5010%90 mL1x501%9 mL10 x501%99 mL1x5012Procedure Start: 500 mL Source Product Copyright Fresenius Kabi AGJuly 26, 2022500 mL SourceProductWash MediaFiltrateWash Cycle: Concentration Phase Copyright Fresenius Kabi AGJuly 26, 202250 mL In-process
14、(Concentrated)FiltrateWash Cycle: Dilution Phase Copyright Fresenius Kabi AGJuly 26, 2022500 mL In-process(Diluted)Wash MediaFiltrateUser-Defined Final Target Product Volume Copyright Fresenius Kabi AGJuly 26, 2022User-definedProduct VolumeFiltrateTheoretical Percent Washout Based upon Concentration
15、 Ratio Copyright Fresenius Kabi AGJuly 26, 2022Number of Wash CyclesConcentration Ratio1*2345610:190%99%99.9%99.99%99.999%99.9999%5:180%96%99.6%99.96%99.996%99.9996%2:150%75%99.5%99.95%99.995%99.9995%Most commonly used washout targets*Lovo is not able to perform a 1-cycle wash. Washout targets for 1
16、-cycle are included for illustrative purposes only.LOVO Cell Processing SystemIntroduction to LovoOverview of Spinning Membrane TechnologyProcedure OverviewReview of Laboratory DataProcessing Parameters and FeaturesKit ConfigurationData Management Copyright Fresenius Kabi AGJuly 26, 2022Lovo Prototy
17、pe Instrument: High supernatant removal with good TNC recovery1 Copyright Fresenius Kabi AGJuly 26, 2022Post-Wash RecoveriesFresh PBMC Products92% TNC Recovery86% Platelet Removal25% RBC Removal99% Supernatant Removal7 min (200 mL to 150 mL) (processing only)Additional Post-Processing Detail1Present
18、ed at the 19th Annual International Society for Cell Therapies Meeting, April 2013. Data collected using prototype instrument. Wegener C, Heber C, Min K (2013). Novel Cell Washing Device Using Spinning Membrane Filtration. Cytotherapy. 15(4) S27. Abstract 86.Post-wash cell recoveries from a 2 wash c
19、ycle protocol using 10:1 concentration ratio. Recoveries are shown as percent of source cell suspension recovered in washed product.Lovo Prototype Instrument: Viabilities between washed and unwashed cells not different1 Copyright Fresenius Kabi AGJuly 26, 20221Presented at the 19th Annual Internatio
20、nal Society for Cell Therapies Meeting, April 2013. Data collected using prototype instrument. Wegener C, Heber C, Min K (2013). Novel Cell Washing Device Using Spinning Membrane Filtration. Cytotherapy. 15(4) S27. Abstract 86.3-Day Lymphocyte Apoptosis Levels(n=5)Day-3 Lymphocyte Proliferation(n=4)
21、LOVO Cell Processing SystemIntroduction to LovoOverview of Spinning Membrane TechnologyProcedure OverviewReview of Laboratory DataProcessing Parameters and FeaturesKit ConfigurationData Management Copyright Fresenius Kabi AGJuly 26, 2022Key Processing Parameters*ParameterLower LimitUpper LimitInput
22、Source Volume Range (mL)On-Scale ProcessingOff-Scale Processing100*100*2500 7000Final Product Volume Range (mL)On-Scale ProcessingOff-Scale Processing505025005000Supernatant Washout Range75%99.9999%Source Packed Cell Volume (PCV) %.1100Number of Wash Cycles26Processing Speed (mL/min)5200 Copyright F
23、resenius Kabi AGJuly 26, 2022* Lower source volume may meet lower limit requirements by increasing source volume with wash media Note: Ranges vary based upon cell type, concentration and source volumeLovo provides additional processing flexibility through admin settings Copyright Fresenius Kabi AGJu
24、ly 26, 2022ParameterDefaultLower LimitUpper LimitBenefitConcentration RatioInlet Flow Rate : Outlet (RET) Flow RateInlet Flow Rate (mL/min)Outlet (RET) Flow Rate (mL/Min)10:1150152:15540:1200200Modify concentration ratio for different cell types and/or cell concentrationsDesired Inlet PCV%3110Balanc
25、e time & final target volumeIdle Spinner Revolution Rate (rpm)60005500Increase or decrease mixing during rinseProcessing Spinner Revolution Rate(rpm)300005500Increase or decrease mean size of cells retainedFinal Product Media Suspension Rate (mL/min)1505200Rate at which you volume up to final target
26、 volumeSource Rinse Volume(mL)200759Increase/decrease to balance cell retention with final product volumeSource Prime Volume(mL)337900Method to add volume to source; rate not configurablePump Speeds Combined with Fluid Management Results in Fast Processing Cell TypeApproximate Source VolumeFinal Tar
27、get VolumeWashout TargetProcessing TimeFresh PBMCs200 mL150 mL 99%7 minsCryopreserved PBMCs240 mL150 mL99%15 mins CD4+ T-Cells2000 mL150 mL99%30 minsJurkat Cells1200 mL100 mL99%25 mins Copyright Fresenius Kabi AGJuly 26, 2022Sample Processing Times* Data are intended to be directional only. Multiple
28、 variables including cell concentration can effect processing times. Data on File.Lovo System FeaturesTwo key features improve cell processing and simplify ease of use:Intelligent AutoDilutionProduct Estimator Copyright Fresenius Kabi AGJuly 26, 2022Understanding Packed Cell VolumePacked Cell Volume
29、 percent (PCV%) is the portion of volume occupied by cellsPCV is an important Lovo processing parameter for both the cell source and the spinning membrane Copyright Fresenius Kabi AGJuly 26, 2022PCV Calculator for LovoLovo System Features:Intelligent AutoDilutionAutoDilution feature automatically di
30、lutes source products with high cell concentrationsAlways active unless an operator selects No DilutionSource PCV range is 1-100%Desired Inlet PCV range is 1% to 10%For example, if the Source PCV is 12% and the Desired PCV is 3%, Lovo will dilute the source product to 3% for processing Copyright Fre
31、senius Kabi AGJuly 26, 2022Lovo System Features:Product EstimatorProvides estimates for Operator to facilitate processing:Processing TimeSupernatant washout %Volume of wash media neededVolume of filtrate produced Copyright Fresenius Kabi AGJuly 26, 2022Using Inlet PCV and Concentration Ratio to Opti
32、mize Lovo Processing Copyright Fresenius Kabi AGJuly 26, 2022Operator can use Concentration Ratio and Desired Inlet PCV to balance other processing goalsExample shown: source volume: 250 mL, source PCV: 15%, target volume: 200 mLLOVO Cell Processing SystemIntroduction to LovoOverview of Spinning Mem
33、brane TechnologyProcedure OverviewReview of Laboratory DataProcessing Parameters and FeaturesKit ConfigurationData Management Copyright Fresenius Kabi AGJuly 26, 2022Lovo Single-Use Processing KitProcessing Kit enables closed system processingTwo tubing leads for washing and/or media solutions2.5 L
34、Filtrate (waste) Container800 mL Retentate (final product) Container800 mL In-Process ContainerSampling ports on the final product (spike and luer) and waste containers (injection port and luer)Spinning membrane module with 4 polycarbonate membrane Copyright Fresenius Kabi AGJuly 26, 2022X6R4901LOVO Cell Processing SystemIntroduction to LovoOverview of Spinning Membrane TechnologyProcedure OverviewReview of Laboratory DataProcessing Parameters and FeaturesKit ConfigurationData Management Copyright Fresenius Kabi AGJuly 26, 2022Data Ma
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025-2030年中国贴剂行业发展现状及前景规划研究报告
- 2025-2030年中国稀土冶炼分离市场运行动态及发展前景分析报告
- 2025甘肃省安全员考试题库附答案
- 南京医科大学《课程论文写作与学术规范》2023-2024学年第二学期期末试卷
- 黔西南民族职业技术学院《外国建筑史》2023-2024学年第二学期期末试卷
- 青海交通职业技术学院《传感检测技术》2023-2024学年第二学期期末试卷
- 天津商业大学《学术论文选题与写作》2023-2024学年第二学期期末试卷
- 湖北大学《财务会计一》2023-2024学年第二学期期末试卷
- 2025上海市建筑安全员考试题库及答案
- 西藏大学《软件交互设计》2023-2024学年第二学期期末试卷
- 小学四年级英语教学反思3篇
- DB1509T 0025-2024 肉牛舍设计与建筑技术规范
- 上海室内装饰施工合同示范文本2024年
- 2024版2024年《汽车文化》全套教案
- 房地产 -中建科工五大类型项目成本指标库
- 2024小红书保健品行业营销通案
- 未来网络支撑下的数字身份体系:产业和技术发展趋势(2024年)定稿版本
- 新《卷烟营销》理论知识考试题库(附答案)
- 中考英语688高频词大纲词频表
- 知识产权保护与跨境执法合作
- 肉类食品配送服务投标方案(技术方案)
评论
0/150
提交评论