下载本文档
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1、Exdata服务器关机和开机方案Exadata关机步骤一 告警灯检查下电之前先检查EXdata主机的ib交换机、网管交换机、数据库服务器、存储服务器、PDU有没有黄灯告警二 系统健康状态检查1. infiniband交换机输入以下命令:versionibhostsshowunhealthyenv_testshowpsufru showtempsshowdiskdmesg2. 网管交换机检查#show running-config3. 存储服务器检查dcli g cell_group l root “ipmitool sunoem cli show faulty”dcli -g cell_gro
2、up -l root -r "reco" "cellcli -e list physicaldisk"dcli -g cell_group -l root -r "reco" "cellcli -e list physicaldisk attributes name,errmediacount where disktype=harddisk and errmediacount>0"dcli -g cell_group -l root -r "reco" "/opt/MegaRAI
3、D/MegaCli/MegaCli64 -Pdlist -a0 |grep 'Slot|Firmware state'"dcli -g cell_group -l root "cellcli -e list griddisk attributes name,asmmodestatus,asmdeactivationoutcome"dcli -g cell_group -l root -r "reco" "biosconfig -get_boot_order | grep DEVICE_NAME"4. 数据库服
4、务器检查dcli g cell_group l root “ipmitool sunoem cli show faulty”dcli -g all_group -l root "/opt/MegaRAID/MegaCli/MegaCli64 -LdInfo -lAll -aAll"dcli -g all_group -l root "/opt/MegaRAID/MegaCli/MegaCli64 -Pdlist -a0 |grep 'Slot|Firmware state'"5. PDU检查登陆到PDU web页面截图三 下电操作1. 关
5、闭数据库节点的集群和数据库首先停止所有数据库节点的CRS使用如下命令:#dcli - g dbs_group -l root “/u01/app/11.2.0.3/grid/bin/crsctl stop crs”注:如果命令执行失败可在命令行末尾加参数 -f 强制关闭CRS2. 在命令执行完毕后执行如下命令验证是否所有节点的crs服务都已经停止,如果无输出就说明所有crs都已停止#dcli -g dbs_group -l root ps -ef |grep d.bin |grep -v grep 3. 停止存储服务器上的cell服务#dcli -g cell_group -l root ”c
6、ellcli -e alter cell shutdown services all”或者#dcli -g cell_group -l root /etc/init.d/celld stop 4. 关闭存储节点的主机#dcli -g cell_group -l root shutdown -h -y now 5. 关闭数据库节点的主机#dcli -g dbs_group shutdown -h -y now6. 手动关闭机柜PDU-A和PDU-B的开关到OFF状态Exadata开机步骤一 确认所需更换的备件已更换完毕,服务器安放回原机柜位置,各种线缆和原安插位置一致二 服务器加电 手动将PDU
7、-A和PDU-B的电源开关调制ON 状态三 按启动开关手动启动节点主机1. 确定infiniband 和cisco交换机完全启动2. 先给cell节点加电开机,系统正常启动-见图23. 然后再给db节点加电开机-见图1 图1图2四 告警灯检查检查EXdata主机的ib交换机、网管交换机、数据库服务器、存储服务器、PDU有没有黄灯告警五 系统健康检查1.重启完成后,cell服务会自动启动,使用如下命令确认cell服务已正常启动#dcli -g cell_group -l root /etc/init.d/celld status2.确认CRS是否正常启动,命令如下:#dcli -g dbs_gr
8、oup -l root /u01/app/11.2.0.3/grid/bin/crsctl stat res -t1.infiniband交换机输入以下命令:versionnm2versionibhostsshowunhealthyenv_testshowfruinfoshowpsufru showtempsshowdiskshowfreeshowsmlogshowtopology2. 网管交换机检查#show running-config3.存储服务器检查dcli -g cell_group -l root -r "reco" "cellcli -e list
9、physicaldisk"dcli -g cell_group -l root -r "reco" "cellcli -e list physicaldisk attributes name,errmediacount where disktype=harddisk and errmediacount>0"dcli -g cell_group -l root "cellcli -e list griddisk attributes name,asmmodestatus,asmdeactivationoutcome,errorco
10、unt"dcli -g cell_group -l root -r "reco" "cellcli -e list griddisk attributes name, asmmodestatus"dcli -g cell_group -l root -r "reco" "grep MemTotal /proc/meminfo"dcli -g cell_group -l root -r "reco" "/opt/MegaRAID/MegaCli/MegaCli64 -Pdlis
11、t -a0 |grep 'Slot|Firmware state'"dcli -g cell_group -l root "cellcli -e list griddisk attributes name,asmmodestatus,asmdeactivationoutcome"dcli -g cell_group -l root -r "reco" "cellcli -e list physicaldisk attributes name,errmediacount where disktype=harddisk&q
12、uot;dcli -g cell_group -l root -r "reco" "cellcli -e list griddisk attributes name, asmmodestatus,asmdeactivationoutcome,eerorcount "dcli -g cell_group -l root -r "reco" "biosconfig -get_boot_order | grep DEVICE_NAME"dcli -g cell_group -l root -r "reco" "biosconfig -get_boot_order | grep DEVICE_NAME"4.数据库服务器检查dcli -g all_group -l root imageinfodcli -g all_group -l root "ipmitool sunoem cli 'show /SYS product_serial_number'" |grep product_serial_numberdcli -g all_group -l root
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 适合风景短视频的文案
- 掌握QE工程师核心技能:2024年培训教材
- 中级中式面点师理论知识模拟题含参考答案
- 2024年PIE工程师培训技能:迈向行业精英的关键路径
- 《弟子规》与2024年教育趋势融合教学
- 2024年贝的故事:教学资源的整合与创新
- 2024年XX企业客户服务文化建设方案
- 小学语文教学设计《棉花姑娘》
- 护理学基础(护理专科(含答案))
- 2024-2025学年新教材高中英语课时分层作业一Unit1Laughoutloud含解析外研版选择性必修第一册
- 02J331地沟及盖板图集
- 2019年西藏开发投资集团有限公司招聘试题及答案解析
- HAY岗位管理体系构建
- 2023年中级经济师考试真题及答案
- SB/T 10895-2012鲜蛋包装与标识
- GB/T 9115-2010对焊钢制管法兰
- GB/T 2423.3-2006电工电子产品环境试验第2部分:试验方法试验Cab:恒定湿热试验
- GB/T 23221-2008烤烟栽培技术规程
- GB/T 16900-2008图形符号表示规则总则
- 城市绿地系统规划 第9章 工业绿地规划
- 辽宁省辽南协作校2022-2023学年高二上学期期末考试语文答案 Word版含解析
评论
0/150
提交评论